Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

Similar documents
RACO Commercial Fittings

Ground Clamps Cable Tray

RACO Commercial Fittings

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

BELL. RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

General Information...SA1-SA4

Thru Wall Floor Seals For New Installation

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

FSK1VDRA 1G Al DPLX RCPT CVR

Beam and Purlin Clamps Beam Clamps

tings fi t fl ex/mc/ac

Wrenches. Wrenches. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Copper Tubing Hangers Clevis Hangers. Copper Tubing Hangers

Ford Water Meter Couplings & Accessories

Available in high-capacity. and assembled by hand for smooth operation. Durable chrome-plated finish. Heat-treated for long life.

E.M.T. Set-Screw Connectors. Technical Specifications

PIPE/CONDUIT SUPPORTS

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

Zinc Cable & Conduit Connectors For Armored Cable, Flexible Metal Conduit & Metal Clad Cable

Iberville. Commercial Grade Fittings EMT CI5410 / CI5432 CI5410IT / CI5432IT CI5404 / CI5408 CI5404IT / CI5408IT CI5004 (-IT) / CI5008 (-IT)

Waterpipe Ground Clamps. 1/2 in., 3/4 in., 1 or rebar /4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 AWG

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

Cast Iron Junction Boxes

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

Tel / (USA & CANADA) /

INTERMEDIATE METAL CONDUIT

ASAP Sr. A Strap and Pole. Magic Christmas. Single Stage. Walter Monkhouse. Alexandria, La. Version 1.2.

Index Pipe Hangers and Straps

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

Product #: Product #:

Steel City Comparison & Strategy. vs. T&B Liquidtight Fittings. Andrea Briggs. Associate Product Manager - Conduit & Fittings FOR INTERNAL USE ONLY

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

STAR TOOL SUPPLY / GRAND TOOL SUPPLY

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth. STRENGTH Diamond serrated jaws provide a firm grip

Assembly Instructions

AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover.

Modular Gazebo Kit Series GardenHouse 12

Dura-Lock Roof System

FIRE PROTECTION PRODUCTS

NORMATIVE REFERENCES

Product Guide Specification

AUXILIARY FRAMING AND ACCESSORIES

Superstrut Stainless Steel Channels and Accessories

NORMATIVE REFERENCES

OXYGEN INSTALLATION. Revision date

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Assembly Instructions 10 X 10 Aluminum Frame Building

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains.

DETAILED ILLUSTRATION

Cat. No. A1200 A1200-S A1200-KO. Finishes & Materials. E142-1/4x100EG 1/4 x 1 A100-5/16EGC A100-3/8EGC. Standard Finish: Electrogalvanized

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

Tuf-Lite II Fans H Hi Temp 3000HT Series Hub

NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit

SWAY BRACE PIPE ATTACHMENT FIG. 010

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

Leveling Feet, Base Plates and Casters

Fastener Basics. Common Fastener Types. Fastener Materials. Grade / Class and Fastener Strength

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

content Introduction Some good reasons to use SMARTr products Reducers, Plugs Conduit Reducer Stopping Plug

Hose Accessories. "Air King" 4 - Lug Quick-Acting Couplings. Hose End. Female N.P.T. End

STEVENS SUBPLATES. STEVENS ENGINEERING, INC. TOLL-FREE WEB FAX

Tuf-Lite III Fans 3000K Series Hub

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01

Rayport G Eco Dealer Kit

Optical Cable Entry Facility (OCEF) Installation Instructions

Clearview Railing System Installation Instructions

BBF Series Blower Base Frame Assembly Instructions Rev.: BFA-9105

Type XTSR71 Sizes

Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM )

Delikon Stainless Steel Liquidtight Connectors offer corrosion resistance and the strength of stainless steel for the highest levels of endurance.

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

Tuf-Lite II Fans 3000H Series Hub

CONTINUING EDUC ATION

Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub

INSTALLATION INSTRUCTIONS FOR FRONT CASTING DECK RAIL Ranger

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

TOOLS AND INSTALLATION

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

Factory Assistance: Phone: Fax: Page 1

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

C-Clamps and Lifting Eyes (Eye Bolts)

SolarMount (E)volution

Tuf-Lite III Fans 5000K Series Hub

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

Tuf-Lite III Fans 5000K Series Hub

Tuf-Lite II Fans 3000H Series Hub

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

THE ROGUE TM FUNSLIDE TM

GLOSSARY OF TERMS SECTION 8

STEEL C-CLAMP WITH LOCKNUT

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe

Tuf-Lite II Fans 3000HC Series Hub

ALUMINUM PIPE GUIDERAIL 01/01/

Transcription:

SECTION E INDEX Product Description Page Number Conduit End Bells.......................................EA Hex Reducing Bushings..................................EA2 Conduit Hubs......................................EA-EA4 Split Couplings.........................................EA Three Piece Couplings...................................EA6 Conduit Nipples........................................EA6 Compression Connectors & Couplings......................EA Set Screw Connectors & Couplings.........................EA8 Conduit Elbows........................................EA9 Offset Nipples.........................................EA0 90 Corner Pulling Ells..................................EA U-Bolts & H-Hangers...................................EA2 Beam Clamps........................................EA Conduit Clamps.......................................EA4 Conduit Straps........................................EA Conduit Spacers & Nest Backs...........................EA6 Cable Tray Clamps.....................................EA8 Combination Couplings.................................EA9 Electroform Inserts.....................................EA20 Watertight Hubs....................................EB-EB

Notes

EA Conduit End Bells Threaded for Rigid Conduit & IMC EA Type TNS For threaded rigid conduit or IMC. Provides a smooth, rounded pulling surface, preventing damage to cable sheath or insulation. Slots are provided for attaching to concrete forms. Malleable or Ductile Iron/ Hot Dip Galvanized Trade Dimensions in Inches Size Catalog Overall Bell Height Max. (Inches) Number (A) (B) Dia. TNS-0 2 6 4 2 TNS-200 2 6 4 2 TNS-20 2 TNS-00 2 6 TNS-0 2 6 4 TNS-400 9 6 2 TNS-00 9 6 2 8 6 TNS-600 2 9 Type TNS

EA2 Hex Reducing Bushings Threaded for Rigid Conduit & IMC EA2 Type 00R Provided with hex shoulder Malleable Iron/Zinc Electroplated Dimensions in Inches Max. Dim. Trade Size Catalog Across Thread Flange (inches) Number Corners Length Thickness - 20-R - 2-R 6 6 UL Listed: E-8-22-R - 2-R 6 6-24-R 6 6 CSA Certified: 99-2-R 6-26-R 6 6 6 UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E NEMA: FB- - 2-R 2-28-R 2-29-R 2-0-R 2 2 - -R 2 2-2-R 2 2 - -R 2 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Type 00R 2-4-R 2 6 6 2 - -R 2 6 6 2-2 6-R 6 6 2 - -R 6 6 2-9-R 6 6-40-R 6 6-2 4-R 6-2 42-R 6 6-49-R 4 6-2 0-R 4 6 4-2 -R 6 4-6-R 4 - -R

EA Raintight Conduit Hubs Threaded for Rigid Conduit & IMC EA Type CHM & Type CHM-T Type CHM - General Purpose Fitting. Type CHM-T - Insulated Throat form with Bonding Locknut. Male thread type Tapered female thread for rigid conduit and IMC Recessed O-ring seal assures watertight and dust tight connections Type CHM-T with insulated throat and bonding locknut is suitable for service entrance application Malleable Iron/Zinc Electroplated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: 8 UL Listed as suitable for wet locations. CSA Certified: 99 Raintight. Suitable for use in hazardous locations as follows: Class I, Div. 2 Class II, Div., 2 Class III, Div., 2 Per NEC 0-4(b), 02-4(a), 0-(a) UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E NEMA: FB- NEMA: 4 NEMA: 2 Note: Minimum wall thickness that can be accommodated is. Dimensions in Inches D Female Trade Size Catalog Tapered Max. Box (inches) Number A B C N.P.T. Wall Thk. CHM-0 CHM- -4 6-4 CHM-00 2 - CHM-2 2 CHM-0 2 2 CHM-200 - - 2-2 CHM-20 2-8 9 6 CHM-00 4-8 CHM-0-8 4 CHM-400 4-8 6 CHM-00 2 6-8 6 6 CHM-600 2 8 6-8 6 Dimensions in Inches Insulated D Throat Female Trade Size Catalog Tapered Max. Box (inches) Number A B C N.P.T. Wall Thk. CHM-0T CHM-T 6-4 - 4 9 CHM-00T 2 - CHM-2T 2 CHM-0T 2 2 CHM-200T - - 2-2 CHM-20T 2-8 2 CHM-00T 4-8 6 CHM-0T - 8 4 CHM-400T 4-8 6 CHM-00T 2 6-8 6 6 CHM-600T 2 8 6-8 6 Type CHM Type CHM-T

EA4 Space-Maker Conduit Hubs Threaded for Rigid Conduit & IMC EA4 Type CH & Type CH-T Type CH - General purpose, suitable for use with heavy wall cabinets Type CH-T - Insulated throat form with bonding screw. Provides a more vibration resistant connection with assured ground continuity Female bushed nipple type Female thread for rigid conduit and IMC Takes less space Recessed O-ring seal outside the box provides a watertight threaded hub on enclosures. Suitable for use with service entrance conduit. Malleable Iron/Zinc Plated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 UL Listed as suitable for use in wet locations. CSA Certified: 99 Suitable for use in hazardous locations as follows: Class I, Div. 2 Class II, Div., 2 Class III, Div., 2 Per NEC 0.4(B), 02.4(A) & (B), 0.(A) & (B) UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E NEMA: FB- NEMA: FB- NEMA: 4 NEMA: 2 Dimensions in Inches A Max. Female Box Trade Size Catalog Tapered Wall (inches) Number B C NPSM Thick. CH-0 CH- CH-00 - - 4-4 9 CH-2 2 - CH-0 2-2 CH-200 2-6 2 2 CH-20 2 2-8 2 CH-00 4-8 2 CH-0 2-8 6 4 CH-400 2 4-8 CH-00 2 6-8 6 CH-600 2 6-8 6 Dimensions in Inches Insulated A Max. Throat Female Box Trade Size Catalog Tapered Wall (inches) Number B C NPSM Thick. CH-0T CH-T CH-00T - - 4 6-4 CH-2T 2 - CH-0T 2-2 CH-200T 2-2 CH-20T 2 2-8 6 CH-00T 2 4-8 6 CH-0T 2-8 6 4 CH-400T 2 4-8 CH-00T 2 6-8 6 CH-600T 2 6-8 6 6 Type CH Type CH-T Notes: Minimum wall thickness that can be accommodated is.

EA Split Couplings For Threaded Rigid Conduit & IMC EA Type SSP A speed union for economically joining two threaded rigid metal conduits. A neoprene gasket provides a concretetight seal at the joint Use where conduit runs are closely spaced Use where conduit is tight against wall, ceiling or other obstruction Use where conduit cannot be turned SSP-00 thru SSP-600: Malleable or Ductile Iron/Zinc Plated SSP-0 and SSP-: Steel/Zinc Plated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 UL Listed as Concretetight. CSA Certified: 99 Trade Size Catalog Dimensions in Inches (inches) Number Length Max. Width Dia. SSP-0 SSP- 2 6 SSP-00 2 SSP-2 2 2 SSP-0 2 2 2 SSP-200 2 6 2 2 SSP-20 6 4 SSP-00 6 4 SSP-0 4 9 6 4 SSP-400 6 SSP-00 6 6 SSP-600 4 8 Type SSP-0 Type SSP-600 Type SSP-00 and SSP-2 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- Installation Instructions: The inside diameter of the split coupling is greater than the outside diameter of the conduit with which it is to be used. To assemble - slip the coupling over one of the threaded conduit ends, butt the two conduit ends together, slide the coupling back over the joint and tighten the hex nut(s). The threaded interior of the split coupling matches with the conduit threads and makes a close fitting mechanically rigid connection with sufficient thermal capacity (I 2 T) to carry ground fault currents equal to wire sizes required by Underwriters Laboratories, Inc. Standard 46 - Table IV, and National Electrical Code Table 20.66. Existing Conduit Type SSP-0 and SSP- Application Illustration

EA6 EA6 -Piece Couplings & Bushed Conduit Nipples Threaded for Rigid Conduit & IMC Type 4 -piece Coupling Couples conduit when neither can be turned. Threaded (NPS) for rigid conduit and IMC Couples conduits when conduits can not be turned Concretetight Malleable Iron/Zinc Electroplated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 CSA Certified: 99 Trade Size Catalog Overall Max. (inches) Number Length Dia. 4-0 6 4-4-00 6 6 4-2 2 6 2 4-0 2 6 2 2 4-200 2 6 2 4-20 6 4 4-00 6 4 6 4-0 4 4-400 4-00 6 6 6 4-600 4 6 8 Type 4 Type Bushed Conduit Nipples Use through knockout to connect box to conduit coupling. Use with a locknut to connect two boxes side by side or back to back. Use with a locknut to connect fixture housings in continuous runs. Available with Insulated Throat. With rigid conduit threads (NPS) Malleable Iron/Zinc Electroplated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 CSA Certified: 99 Insulated Dimensions in Inches Throat Max. Dia. Trade Size Catalog Catalog Across Thread Flange (inches) Number Number Corners Length Thickness -8 --- -0-0T - -T -00-00T -2-2T 2-0 -0T 2 6 2-200 -200T 2-20 -20T -00-00T 4-0 -0T 4-400 -400T -00-00T 6 6-600 -600T Not CSA Certified 6 6 6 6 Type UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec. W-F-408E NEMA: FB-

EA EA Compression Rigid Connectors & Couplings For Threadless Rigid Conduit Type Gland Compression Connectors To connect threadless rigid conduit to boxes and enclosures. Concretetight Male hub threads (NPS through 2 ; NPT above 2 ). Malleable Iron/Zinc Electroplated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 Insulated Throat Dimensions in Inches Trade Size Catalog Catalog Body Max Thread (inches) Number Number Length Dia. Length -00-00T -0-0T 9 6-00 -00T 6 6-2 -2T 2 6-0 -0T 2 2-200 -200T 6 2-20 -20T 2 4-00 -00T 2 6 4 6-0 -0T 2 6 4-400 -400T 2 9 6 6-00 -00T 2 6 6-600 -600T 2 8 9 6 Not UL Listed 6 6 9 6 6 Type -00 Type -200 Type -20 Type -600 UL Standard: 4B Fed. Spec: W-F-408E NEMA: FB- Type 0 Gland Compression Couplings To couple sections of threadless rigid conduit together. Concretetight Malleable Iron/Zinc Electroplated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 Trade Size Catalog Dimensions in inches (inches) Number Length Max. Dia. 0-00 6 0-0 9 6 0-00 6 6 0-2 2 2 6 0-0 2 9 6 2 2 0-200 2 6 2 0-20 6 4 0-00 4 6 4 6 0-0 4 4 0-400 4 9 6 6 0-00 6 0-600 4 8 9 6 Not UL Listed Type 0-00 Type 0-200 Type 0-20 Type 0-600 UL Standard: 4B Fed. Spec: W-F-408E NEMA: FB-

EA8 Set-Screw Rigid Connectors & Couplings For Threadless Rigid Conduit & IMC EA8 Type 28 To connect threadless rigid conduit to boxes and enclosures. Concretetight. Available with insulated throat. Male hub thread (NPS) Malleable Iron/Zinc Plated Optional Finish: - Mechanically Galvanized 2-6 Hot Dip Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 Insulated Throat Dimensions in Inches Trade Size Catalog Catalog Body Max Thread (inches) Number Number Length Dia. Length 28-00 28-00T 28-0 28-0T 6 6 28-00 28-00T 6 28-2 28-2T 9 6 2 28-0 28-0T 2 2 28-200 28-200T 2 6 6 2 28-20 28-20T 2 9 6 28-00 28-00T 2 4 28-0 28-0T 2 4 4 28-400 28-400T 28-00 28-00T 4 6 6 28-600 28-600T 4 Type 28-00 Type 28-200 Type 28-20 Type 28-600 UL Standard: 4B Fed. Spec: W-F-408E NEMA: FB- Type 29 To couple sections of threadless rigid conduit together. Concretetight Malleable Iron/Zinc Plated Optional Finish: Optional Finish: - Mechanically Galvanized 2-6 Hot Dip Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 Trade Size Catalog Dimensions in Inches (inches) Number Length Max. Dia. 29-00 29-0 2 6 29-00 2 29-2 2 2 29-0 2 2 29-200 2 2 29-20 9 6 29-00 4 4 29-0 4 4 29-400 29-00 6 6 29-600 8 Type 29-00 Type 29-200 Type 29-20 Type 29-600 UL Standard: 4B Fed. Spec: W-F-408E NEMA: FB-

EA9 EA9 90 Bushed & 90 Corner Pull-in Conduit Elbows Threaded For Rigid Conduit & IMC Type 9 Available with insulated throat Threaded for rigid conduit, Female NPT Male NPS Telephone elbow, floor outlet fittings Malleable Iron/Zinc Electroplated Insulated Throat Trade Size Catalog Catalog Dimensions in Inches (inches) Number Number A B C 9-0 9-0T 9-9-T 2 6 2 6 9-00 9-00T 2 2 9-2 9-2T 6 6 Optional Finish: Mechanically Galvanized. Contact your local representative for pricing and availability. Type 9 UL Listed: E-8 and 8 CSA Certified: 99 UL Standard: 4 CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E NEMA: FB- Type CE Malleable Iron/Zinc Electroplated UL Listed: E-8 Trade Size Catalog Dimensions in Inches (inches) Number A B CE-00 2 2 CE-0 2 2 CE-000 2 UL Standard: 4B NEMA: FB- Type CE

EA0 Offset Nipples Threaded For Rigid Conduit Type ON Rigid conduit threading. Provides box-to-box connection of knockouts. Allows misaligned knockout connection by rolling the offset nipple until aligned with each knockout. Feature: Available with insulated throat. Malleable Iron/Zinc Plated Optional Finish: Mechanically Galvanized. Contact your local representative for pricing and availability. UL Listed: E-8 Insulated Dimensions in Inches Throat Thread Trade Size Catalog Catalog Body Length Type (inches) Number Number Length Each End Thread ON-0 ON-0T 6 ON- ON-T ON-00 ON-00T ON-2 ON-2T ON-0 ON-0T 2 ON-200 ON-200T NPS NPT 9 6 NPT 6 NPT NPT 6 NPT Type ON EA0 CSA Certified: 99 UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E NEMA: FB-

EA 90 Raintight Corner Pulling Ells Threaded For Rigid Conduit & IMC EA Type FF 90 Female/Female Trade Size Catalog Dimensions in Inches (inches) Number A B Provides a compact wire-pulling point and a 90 change of direction in a conduit run. Threaded for rigid conduit and IMC (NPT) Furnished with Neoprene gasketed steel cover, zinc electroplated. Raintight Malleable Iron/Zinc Plated UL Listed: E-8 FF-00 6 FF-0 2 9 6 FF-00 2 6 FF-2 2 6 FF-0 2 9 6 2 FF-200 4 2 FF-20 6 FF-00 6 6 Type FF CSA Certified: 99 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- Type MF 90 Male/Female For connecting rigid conduit or IMC to box or enclosures. Threaded for rigid conduit and IMC Female NPT, Male NPSM Furnished with neoprene gasketed, steel cover, zinc plated. Furnished with locknut. Raintight Available with insulated throat Malleable Iron/Zinc Electroplated UL Listed: E-8 Insulated Throat Trade Size Catalog Catalog Dimensions in Inches (inches) Number Number A B C MF-00 MF-00T MF-0 MF-0T 2 MF-00 MF-00T 2 MF-2 MF-2T 2 MF-0 MF-0T 2 6 2 MF-200 MF-200T 4 2 6 6 9 6 6 6 6 2 MF-20 MF-20T 6 MF-00 MF-00T 6 6 Type MF CSA Certified: 99 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB-

EA2 Conduit U-Bolts & Hangers Threaded For Rigid Conduit, IMC & EMT EA2 Type U Conduit U-Bolts Dimensions in Inches Trade Size Catalog Thread (inches) Number A B C D Size 2 hex nuts Material: Steel Finish: Mechanically Galvanized U-0SG 6 6 2 U-SG 6 2 U-00SG 6 2 6 U-2SG 2 6 U-0SG 2 2 6 2 U-200SG 2 2 4 2 U-20SG 4 U-00SG 4 U-0SG 4 4 6-20 - 20 6-8 6-8 6-8 - 6-6 - 6-6 Type U 4 U-400SG 4 6 U-00SG 6 6 U-600SG 6 6 6 8-6 - 6-6 Type H Conduit Hangers Steel/Zinc Plated With Bolt/Nut Dimensions in Inches Trade Size Catalog Clamping (inches) Number A B C Bolt Size - ** H-0WBS 2-20, ** H-WBS 2 6-20, H-2WBS 2 9 6 EMT H-2 WBS 2 6-20, - 20, * H-WBS - 20, H-4WBS 6 9 6-20, 2 H-WBS 6 6-20, 2 H-6WBS 4 2 6-20, H-WBS 4 2-20, H-8WBS 2 6-8, 4 H-9WBS 6 -, Type H-WBS with clamping bolt **Furnished with carriage bolt

EA Beam Clamps EA Type IS Provides support for conduit hanging systems. Material: Malleable Iron clamp Steel Screw, case hardened Finish: Clamp - Hot Dip Galvanized Screw - Zinc Electroplated A B Max. Catalog Tapped Jaw Dimensions in Inches Load Number Holes Opening C D E (lbs.) IS-00-20 6 IS-09 0-24 6 IS-0 6-8 6 6 2 IS-02-6 2 6 2 0 IS-0-6 2 2 900 Type IS C B - Jaw Opening D A - Tapped Holes (2) Load E

EA4 Conduit Clamps EA4 Type UBC Right Angle Type UPC Parallel Type UEC Edge type Designed to secure rigid, IMC or EMT across, parallel or perpendicular to beam, channel and angle supports. Easily installed Capable of withstanding heavy loads Material: All components are Malleable Iron except nuts and bolts which are steel. Finish: Clamp - Hot dipped Galvanized Hardware - Mechanically Galvanized Type UBC-G Type UPC-G Type UEC - G Note: Edge type UEC used for rigid conduit only. Right Parallel Edge Angle Type Type Type Trade Size Catalog Catalog Catalog (inches) Number Number Number UBC-0G UPC-0G UEC-0G UBC-G UPC-G UEC-G UBC-00G UPC-00G UEC-00G UBC-2G UPC-2G UEC-2G UBC-0G UPC-0G UEC-0G 2 UBC-200G UPC-200G UEC-200G 2 UBC-20G UPC-20G UEC-20G UBC-00G UPC-00G UEC-00G UBC-0G UPC-0G 4 UBC-400G UPC-400G UBC-00G 6 UBC-600G

EA Pipe Straps For Rigid Conduit & IMC Type 4-S To support rigid conduit and IMC. Snap type - double ribbed Steel/Zinc Plated Fed. Spec: FF-S-60 Note: 2 through 4 sizes also suitable for EMT. Steel Dimensions in Inches Straps Minimum Trade Size Catalog Recommended (inches) Number A B C Bolt Dia. 4-0S 2 6 4-S 2 9 6 6 4-00S 2 6 4-2S 6 4-0S 6 2 4-200S 4 2 2 4-20S 6 6 2 4-00S 6 4-0S 9 6 4 4-400S 8 6 6 Type 4-S EA Type THR To support rigid conduit and IMC. Snap type - double ribbed Steel/Zinc Plated CSA Certified: 0469 through 2 sizes only CSA C22.2 No.8 Fed. Spec: FF-S-60 Note: 2 through 4 sizes also suitable for EMT. Steel Dimensions in Inches Straps Minimum Trade Size Catalog Recommended (inches) Number A B C Bolt Dia. THR-0S 2 THR-S 2 2 6 THR-00S 2 6 2 6 THR-2S 2 6 2 2 THR-0S 6 2 2 THR-200S 4 2 2 THR-20S 4 6 2 6 THR-00S 6 6 6 THR-0S 6 6 6 6 4 THR-400S 6 2 6 6 6 6 Type THR Type 4-G To support rigid conduit and IMC. Malleable Iron/Hot Dipped Galvanized CSA Certified: 99. CSA: C22.2 No.8 Fed. Spec: FF-S-60 Note: 2 through 4 sizes also suitable for EMT. Malleable Dimensions in Inches Straps Conduit Minimum Catalog Size Recommended Number Inches A B C Bolt Dia. 4-8G 6 4-2G 9 4-8G 4-0G 2 9 2 #0 6 4-G 2 9 6 4-00G 6 6 4-2G 6 4-0G 6 2 4-200G 2 6 2 9 6 4-20G 2 6 6 4-00G 6 6 4-0G 8 6 6 4 4-400G 4 8 6 2 4-00G 0 6 2 6 4-600G 6 2 Type 4-G

EA6 Clamp Backs & Conduit Spacers For Rigid Conduit, IMC & EMT EA6 Clamp Backs Provides spacing from mounting surface when used with malleable iron pipe straps. Material: Malleable Iron Finish: Hot Dip Galvanized Trade Size Catalog Dimensions in Inches (inches) Number A B C D E 4G 6 6 42G 2 4G 6 6 6 44G 6 6 6 4G 6 6 2 46G 2 2 4G 2 48G 2 6 49G 8 6 9 6 9 6 x 9 6 x 6 9 6 x 6 9 6 x 9 x 2 x 6 x x 6 x Clamp Back CSA Certified: 99 4 0G 8 6 G 0 6 6 6 2G 6 2 6 2 x 9 2 x 6 9 6 x 2 CSA Standard: C22.2 No. 8 Conduit Spacers For use with malleable iron pipe straps and clamp back, to provide additional spacing between conduit and mounting surface. Spacers fit snugly under clamp back and makes possible additional spacing away from the mounting surface. Spacers can stack up into each other so that conduit can be installed at any desired distance from walls or ceilings. Materials: Malleable Iron Finish: Hot Dip or Mechanical Galvanized CSA Certified: 99 CSA Standard: C22.2 No. 8 Trade Size Catalog Dimensions in Inches (inches) Number Length Width Thickness 4-NG 2 6 42-NG 2 4-NG 6 6 44-NG 4-NG 6 9 6 2 46-NG 6 2 6 2 4-NG 6 2 9 6 48-NG 6 2 6 49-NG 8 4 0-NG 8 6 Nest Back Fitting Not included Not included Typical Installation

EA Conduit Clamps For Rigid Conduit, IMC & EMT Type J For securing rigid conduit, IMC, EMT and Flexible Metal conduit. Material: Malleable or Ductile Iron Steel Bolt EA Finish: Mechanically Galvanized CSA Certified: 99 CSA Standard: C22.2 No. 8 Type J Zinc Plated Dimensions in Inches Trade Size Catalog (inches) Number A B C D Bolt Size J-0G 2 9 6 6-8 x J-G 2 2 6-8 x J-00G 2 6 2 6 J-2G 2 2 9 6 J-0G 4 6 2 2 2 2 J-200G 4 6 2 6 6 2 - J-20 6 6 4 6 2 4 9 6 - J-40 6 6-8 x -6 x -6 x - x - x 2 - x 2 Type CBC Conduit C Clamp For securing rigid conduit, IMC and EMT. Swivel grip rotates a full 60. Malleable Iron/Zinc Plated Steel square head screw Optional Finish: Mechanically Galvanized Contact your local representative for pricing, availability and minimum order quantities. Note: CBC- is maximum beam thickness when using conduit. 2 CBC-2 is maximum beam thickness when using 2 conduit. Trade Size Catalog Dimensions in Inches (inches) Number Length Width - - - CBC- 2 9 6 - - 2 CBC-2 4 Swivel Grip Type CBC

EA8 Tray-Bond Cable Tray Clamps For Rigid Conduit, IMC & EMT EA8 Type CTC For connecting and grounding rigid conduit, IMC, or EMT to cable trays. Secures and bonds metal conduit (rigid steel or aluminum, IMC and EMT) to the side rails of steel or aluminum cable trays without drilling or welding the tray. On the through 4 sizes, conduits can attach to the tray from any angle up to 20, allowing large power or control cables to be routed easily. Type CTC-00 & Type CTC-02 Sizes Right Angle to Tray Type CTC-0 & Type CTC-400 4 Sizes Variable Angle to Tray Fast Installation Low Product Cost Excellent Grounding Continuity Variable Conduit Entry - 4 sizes High Mechanical Strength Compact Design Meets NEC 8- (b)(4) Bonding Requirements Suggested Specifications: Raceways connected to cable trays shall be properly bonded using UL Listed and CSA Certified bolted mechanical connectors made from malleable iron, hot dip galvanized components and steel, mechanically galvanized bolts. The cable tray conduit clamps shall be O-Z/Gedney, Type CTC. How Tray-Bond Clamps Work: The edge of the cable tray rail provides the surface on which the serrations in the clamps grounding pad bite into the tray. The lower portion of the clamp has a sharp triangular edge which grabs the underside of the rail. As the U-bolt is tightened, all the force is concentrated in the clamping jaws thus providing an excellent grounding path and high strength mechanical attachment. Malleable Iron/Mechanically Galvanized U-Bolts and Nuts: Steel/Mechanically Galvanized UL Listed: E-24264 Rigid or IMC, EMT Dimensions in Inches Recommended Trade Size Catalog U-Bolt & Ins. Torque (inches) Number Nut Size W L T U In. - Lbs. - CTC-00-20 2 2 2 60 - CTC-02 6-8 2 2 CTC-0 6-8 2 CTC-200-6 4 4 4 90 2 CTC-20-6 4 4 90 CTC-00-6 90 CTC-0-6 6 90 4 CTC-400-6 6 6 6 90 *Insulated Bushing not included Type CTGC Cable Tray Grounding clamps for use on most types of cable trays. See page MA2. PATENTED CSA Certified: 99 for rigid and EMT only UL Standard: 46 CSA Standard: C22.2 No. 8

EA9 Combination Couplings For Rigid Conduit, IMC & EMT EA9 Type ETR Threaded rigid and IMC to compression EMT Concretetight NPT female hub Malleable Iron/Zinc Plated Trade Size Catalog Dimensions in Inches (inches) Number Length Max Dia. ETR-0 ETR- 6 ETR-00 ETR-2 2 ETR-0 2 2 ETR-200 2 6 UL Listed: E-8 Type ETR UL Standard: 4B Fed. Spec: W-F-408E Type CB Threaded rigid and IMC to flexible metal Rigid hub NPT threads Malleable Iron, Zinc Plated Dimensions in Inches Trade Size Catalog Flex. (inches) Number Length Max Dia. Range CB-0 CB- 2-6 29-64 CB-00 9-6 UL Listed: E-8 Type CB CSA Certified: 99 UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E Type ESR Concretetight Set screw Threadless rigid and IMC to EMT Trade Size Catalog Dimensions in Inches (inches) Number A B C ESR-0 6 6 ESR- 2 6 ESR-00 2 6 Malleable Iron/Zinc Plated UL Listed: E-8 Type ESR UL Standard: 4B Fed. Spec: W-F-408E

EA20 Concrete Slab Electroform Inserts For Threaded Rigid Conduit & IMC EA20 Type EF & Type EFL For conduit installed in poured concrete slabs. Nail, screw or tack-weld insert to concrete deck form. Inserts available in straight or 90 Malleable Iron/Zinc Plated UL Listed: E-8 CSA Certified: 99 UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E Type EF-0 Type EF-00 For concrete slab 4 thick and up. STRAIGHT CONDUIT INSERTS Dimensions in Inches Base Trade Size Catalog Base Across (inches) Number Dia. Flats Height Type EFL-0 Type EFL-00 For slabs 6 thick and up require bend conduit sweep. EF-0 6 6 EF- 2 6 2 EF-00 2 6 90 CONDUIT INSERTS Dimensions in Inches Base to Trade Size Catalog Base Turning Conduit (inches) Number Dia. Radius Center Height EFL-0 6 EFL- 2 6 6 6 6 EFL-00 2 6 2 6 6 Shown in poured concrete slabs before wood or steel forms are removed.

EB Watertight Hubs Die Cast, Insulated and Gasketed EB Used in applications to connect rigid metal conduit or IMC to a threadless opening in an enclosure. May be used in wet or dry locations, indoors or outdoors. Suitable for hazardous locations: Class I, Division 2; Class II, Divisions & 2; Class III, Per NEC 0.4(B), 02.4(A) & (B), 0.(A) & (B). Rugged metallic construction ensures mechanical protection. Die cast design provides clean lines and aesthetic appeal. Insulated throat, rated up to 0 C, prevents wire abrasion. Integral O-ring provides watertight seal. Grounding version provides positive ground for external conductor. Unique profile permits easy wrenching. Smooth, accurately tapped threads facilitate installation. Watertight and corrosion resistant: NEMA 4X. NEMA 2. Material: Bodies and nuts: Die Cast Zinc O-ring: BUNA-N Insulator: Polycarbonate Ground Screw: Mild Steel Size Ranges: /2" through 4" CHM CHMG Optional Finishes: Chrome plating optional add suffix C. UL Listed UL Standard 4B CSA Certified (incl. Class II, Groups E, F, G) CSA Standard C22.2-8-98 NEMA Type 2,, R, 4, 4X,, 2, NEMA Standard FB- O-Z/Gedney UL File No. E8 O-Z/Gedney CSA File No. LR99

EB2 Watertight Hubs Die Cast, Insulated and Gasketed EB2 B A G H D C F E CHM Series CHMG Series Die Cast Hubs Insulated (All dimensions are in inches.) Panel Catalog Trade Hole Dia. Thickness Dimensions Number* Size Min. Max. Min. Max. A B C CHM-0DT /2 0.86-0.9 0.026-0.2 0.84 0.64.44 CHM-DT /4.08 -.4 0.026-0.2 0.94 0.64.69 CHM-00DT. -.4 0.026-0.2.0 0.8 2.00 CHM-2DT -/4.6 -. 0.026-0.2.2 0.8 2.8 CHM-0DT -/2.92-2.02 0.062-0.2.2 0.8 2. CHM-200DT 2 2.6-2.0 0.062-0.2.2 0.8.2 CHM-20DT 2-/2 2.86 -.00 0.062-0..6.06.2 CHM-00DT.48 -.6 0.062-0..6.06 4.8 CHM-0DT -/2.98-4.6 0.062-0..6.06 4.94 CHM-400DT 4 4.48-4.6 0.062-0..6.06.4 * For chrome plating, add suffix C. Grounding Style Hubs Insulated (All dimensions are in inches.) Panel Catalog Trade Hole Dia. Thickness Dimensions Number* Size Min. Max. Min. Max. D E F G H CHMG-0DT /2 0.86-0.9 0.026-0.2 0.84 0.64.44 0-2X/4 0.69 CHMG-DT /4.08 -.4 0.026-0.2 0.94 0.64.69 0-2X/4 0.8 CHMG-00DT. -.4 0.026-0.2.0 0.8 2.00 0-2X/4 0.8 CHMG-2DT -/4.6 -. 0.026-0.2.2 0.8 2.8 /4-20X/8 0.8 CHMG-0DT -/2.92-2.02 0.026-0.2.2 0.8 2. /4-20X/8.00 CHMG-200DT 2 2.6-2.0 0.026-0.2.2 0.8.2 /4-20X/2.00 CHMG-20DT 2-/2 2.86 -.00 0.062-0..6.06.2 /4-20X/2.2 CHMG-00DT.48 -.6 0.062-0..6.06 4.8 /4-20X/2.2 CHMG-0DT -/2.98-4.6 0.062-0..6.06 4.94 /4-20X/2. CHMG-400DT 4 4.48-4.6 0.062-0..6.06.4 /4-20X/2. * For chrome plating, add suffix C.

EB Watertight Hubs Grounding Nuts and Hub Spacing Chart EB L I K J CHML Series Grounding Nuts (All dimensions are in inches.) Catalog Trade Wire Size Wire Size Dimensions Number* Size Min Max I J K L CHML-0D /2" #4 stranded #0 stranded 0.69 0..44 0 2x/4 CHML-D /4" #4 stranded #0 stranded 0.8 0.8.69 0 2x/4 CHML-00D " #4 stranded #0 stranded 0.8 0.8 2.00 0 2x/4 CHML-2D -/4" #0 solid #6 stranded 0.8 0.44 2.8 /4 20x/8 CHML-0D -/2" #0 solid #6 stranded.00 0.4 2. /4 20x/8 CHML-200D 2" #0 solid #6 stranded.00 0.4.2 /4 20x/2 CHML-20D 2-/2" #0 solid #6 stranded.2 0.6.2 /4 20x/2 CHML-00D " #0 solid #6 stranded.2 0.6 4.8 /4 20x/2 CHML-0D -/2" #0 solid #6 stranded. 0.69 4.94 /4 20x/2 CHML-400D 4" #0 solid #6 stranded. 0.69.4 /4 20x/2 * For chrome plating, add suffix C. Hub Spacing Chart (All dimensions are in inches.) Knockout Trade Hole Size Size /2" /4" " -/4" -/2" 2" 2-/2" " -/2" 4" /8" /2".6 -/8" /4".69.8 -/8" ".84.9 2. -/4" -/4" 2.0 2.6 2. 2.0 2" -/2" 2.22 2.4 2.0 2.69 2.88 2-/2" 2" 2.4 2.9 2. 2.9..8 " 2-/2" 2.2 2.84.00.9.8.6.88 -/8" ".0.6..0.69.8 4.49 4.0 4-/8" -/2".4.4.6.8 4.00 4.2 4.0 4.8. 4-/8" 4".9 4.2.88 4.06 4.2 4.0 4..06.8. Dimensions in bold are for centers of conduits of same size, all other dimensions are for centers of conduits of a different size. Minimum spacing dimensions as shown above will give approximately /8" clearance between the lock nuts.

Notes