LENGTH IDENTIFICATION

Similar documents
POWER-Skru Large Diameter Concrete Screw

PRODUCT INFORMATION. ASTM B633,SC1, Type III (Fe/Zn 5) Rod/Anchor Diameter

Letter of Transmittal/Submittal

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

Large Diameter Tapcon

Peco Fasteners 3/8 Internal Plug Drop In 50 Per Jar 3/8-16 SMART DROP IN ANCHOR ZINC

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW

ANCHORS SLEEVE ANCHORS BOLT DIAMETER

Umbrella Inserts and Stubby Screens

BUILT BY AMERICA. CONNECTED WORLDWIDE.

POWER-Drop Drop-In Anchors

Multi-Set II Drop-In Anchors

SECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here)

Hollo Set Drop-In Anchors

Umbrella Inserts and Stubby Screens

YOUR ONE SOURCE FOR CONCRETE FASTENERS PRODUCT CATALOG. p f East 40th Street Cleveland, Ohio

Sigma Fasteners, Inc. Section 7

Dimensions Mechanical and Performance Requirements. Drop-In Anchors Hollow Wall, Steel Regular Style Drive Style...

Ready To Go SimpleSpec tm. Installation Manual. For more information, please visit 3-form.com or call

The Quick, Economical Method to Secure Hurricane Protection

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners?

Evaluation of In-Pavement Light Fixture Designs and Performance

Procedure for Wrench Calibration and Snug Tightening

STRUCTURAL ATTACHMENTS

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

The All American Anchor is a positive drive positive setting anchor for use in all masonry materials / / /8 7 1/ /16

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

The Saddle Rack. For Power And Communication Cables

Wedge Type Anchors. Trubolt. Wedge Anchor ADVANTAGES

Installation Instructions

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

DYNABOLT PLUS ANCHORS DYNABOLT PLUS. Anchor Details. Installation Ramset Regions. Site Map. Home Page. Performance. Next Page. Date of Issue: 9/98

1. VERIFY ALL COMPONENTS

Fixings & Fastenings. Bright Zinc Plated, Galvanised & Stainless Steel. Lockinex. ea i, ea u i

Procedure for Testing Direct Tension Indicators (DTI) Assemblies

FNW can handle all your hanger and fastener needs, all in one place. FNW products are sold exclusively at Ferguson.

Assembly Instructions

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

HSL-3 / HSL-3-R EXPANSION ANCHOR. Technical Datasheet Update: Oct-18

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the grade A325 structural bolt.

Various Bolt Removal Process

STRATUS SHELTER. Take bike parking to new heights

HSV EXPANSION ANCHOR. Technical Datasheet Update: Dec-17

HSL-3 / HSL-3-R EXPANSION ANCHOR. Technical Datasheet Update: Dec-17

Buyers Guide. Pg. 74 Bronze Screws High Speed Drill Bits Pg. 106 Packaged Fasteners Pg. 108

Various Bolt Removal Process

Hang-TITE Rod Hanger Screws

Independent Containment System (ICS)

C O N S T R U C T I O N F A S T E N E R S S T E E L POWDER ACTUATED CARBIDE DRILL BITS

ALLIGATOR All-Purpose Anchors

SUPER HOLD ANCHORS P/N 17849

TREX POST MOUNT DECKING AND CONCRETE

TAPTITE Fasteners. High Performance Thread Rolling Screws for Metals

HANDLING AND ASSEMBLY INSTRUCTIONS FOR TRUE FOCUS 3.0M, 3.8M AND 4.2M ANTENNAS WITH POLAR MOUNT

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

RELINER INSIDE DROP SYSTEM SPECIFICATIONS

Powder Actuated Fastening INTRODUCTION

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Screens

PREPARATION & TOOL CHECK LIST

Installation Instructions

DTFACT 16 C IN PAVEMENT LIGHT FIXTURE TESTING AND ANALYSIS FINAL SUMMARY PRESENTATION

INSTALLATION GUIDE. Version 2.0

c. Pins, bolts, and retaining rings b. Washers, locking nuts, and rivets

Tex-452-A, Rotational Capacity Testing of Fasteners Using a Tension Measuring Device

Fastener Type Chart. Fastener Categories. Sheet Metal Screws Fully threaded screws with a point for use in sheet metal. Abbreviated SMS.

Cone. Bolt. Rubber Washer. Rubber Washer. compressed / increased clamping force

Contents. Grade 2, 5, 8 Hex Bolts 4. Heavy Hex Head Structural Bolts 6. A325 and A490 Tension Control Bolts (TC) 13. Nuts 22.

RBP-1215B-RX DODGE RAM QUAD CAB RX3

MTS-ZB. RENOGY Photovoltaic Module Z-Bracket Mounting System E Philadelphia St, Ontario, CA Version: 1.

Leveling Feet, Base Plates and Casters

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

CONTENTS. Hammerscrews White Zinc Plated 2 Hammerscrews Stainless Steel A Nylon Frame Anchors Yellow Zinc Plated 3 Nylon Plug 3

HARDLOCK NUT RIM & HARDLOCK NUT BASIC

PRICE BOOK NO. 204S ORDERING INFORMATION

PURE GP. Adhesives GENERAL INFORMATION SECTION CONTENTS. Epoxy Injection Adhesive Anchoring System

KOLO SHELTER Installation Instructions Parts List

MISCELLANEOUS SIGN CONNECTION DETAILS TYPICAL ROUTE MARKER ASSEMBLIES SIGN TO POST MICHIGAN DEPARTMENT OF TRANSPORTATION

May 14, Installation Manual

Installation and Assembly: Flat Panel Pull-out Swivel Wall Mount

PREPARATION & TOOL CHECKLIST

Installation and Assembly: Full Service Video Wall Mount

SM-RAZOR-F-M/L/XL. Strong Low Profile Fixed Mount for Ultra-Thin Flat-Panel TVs INSTALLATION MANUAL

Bumper Sign INSTALLATION INSTRUCTIONS

Quarter-Turn Fasteners

MAKO EC EXTENDED CABINET

MTS-ACB. RENOGY Photovoltaic Module Adjustable Curved Bracket E Philadelphia St, Ontario, CA Version: 1.

Max. Rec. Load. Wt. Per Inch lbs. kn lbs. kn lbs. kg. Wt. Per Inch lbs. kn lbs. kn lbs. kg 750 F (399 C)

TECHNICAL CORRECTION October Process Industry Practices Structural. PIP STF05121 Fabrication and Installation of Anchor Bolts

MX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

Special Thumb Screw Order Form

SM-RAZOR-T-M/L/XL. Strong Low Profile Tilt Mount for Ultra-Thin Flat-Panel TVs INSTRUCTION MANUAL

Elco Construction Products 1301 Kerr Drive Decorah, IA fax:

Hardened Structures Hardened Shelters, LLC. Explosion Resistant Pre-hung Sealed Blast Door

INSTALLATION GUIDE. Flat Panel Arm Mount MLA100-L. VESA 100x100 compatible. Support 10" to 24" Screens Max Load Capacity: 30 lbs (15 kg)

INSTALLATION INSTRUCTIONS PART#:17A045200MSS\17A045200MA MODULAR GRILL GUARD FOR FORD SUPER DUTY F250/F

AIRCRAFT HARDWARE What You Need To Know By Ron Alexander

Installation Instruction

Transcription:

58 Power-Bolt HEAVY DUTY, ELF-UNDERCUTTING LEEVE TYPE BAE MATERIAL Concrete, Block, Brick, tone IZE RANGE 1/4" x 1" to 1-1/4" x 9 MATERIAL LENGTH IDENTIFICATION The Power-Bolt anchor has a length identification mark stamped on the head of the anchor as shown, making inspection of installed anchors easy. MARK A B C D E F G H From 1-1/2 2 2-1/2 3 3-1/2 4 4-1/2 5 Up to 2 2-1/2 3 3-1/2 4 4-1/2 5 5-1/2 MARK I J K L M N O P From 5-1/2 6 6-1/2 7 7-1/2 8 8-1/2 9 Up to 6 6-1/2 7 7-1/2 8 8-1/2 9 9-1/2 INTALLATION PROCEDURE Using the proper diameter bit, drill a hole into the base material to a depth Carbon teel & Type 304 tainless teel of at least 1/2 or one anchor diameter deeper than the embedment PRODUCT DECRIPTION required. The tolerances of the drill bit The Power-Bolt anchor (formerly known as the Rawl-Bolt) is a heavy duty used should meet the requirements of sleeve style self-undercutting anchor which is vibration resistant and removable. ANI tandard B212.15. It is available with a finished hex head or flat head with a hex key insert and can be used in concrete, block, brick, or stone. Washer Bolt Flat Head Bolt Hex Insert Extension leeve Compression Ring Extension leeve Compression Ring Length Length Diameter Diameter Expander Cone Dust Cover Expander leeve Expander Cone Dust Cover Expander leeve Blow the hole clean of dust and other material. Do not expand the anchor prior to installation. Drive the anchor through the fixture into the anchor hole until the bolt head is firmly seated against the Expansion occurs at two levels within the drilled hole. First, the cone is pulled fixture. Be sure the anchor is driven to into the large triple-tined expansion sleeve, developing a mid-level, compression the required embedment depth. force. Further turning causes the threaded bolt to advance into the threads of the expander cone, forcing its four sections outward. This action undercuts the base material deep in the anchor hole, greatly increasing the holding power of the Power-Bolt. The bolt and cone remain locked together which prevents loosening under even Tighten the anchor by turning the the most severe vibratory conditions. head 3 to 5 turns past finger tight or The Power-Bolt is also designed to draw the fixture into full bearing against the by applying the guide installation base material through the action of its flexible compression ring. As the anchor torque from the finger tight position. is being tightened, the nylon compression ring will crush if necessary to tightly secure the fixture against the face of the base material. The internal bolt of the Power-Bolt is removable and reusable in the same anchor hole making it ideal for applications such as mounting machinery which may need to be removed for service and for temporary applications such as heavy duty form work.

59 IZE AND TYLE The following tables list the sizes and styles of standard Power-Bolt anchors including both zinc plated carbon steel and stainless steel. To select the proper minimum anchor length, determine the embedment depth required to obtain the desired load capacity. Then add the thickness of the fixture, including any spacers or shims, to the embedment depth. CARBON TEEL HEX HEAD POWER-BOLT Carbon steel Power-Bolt anchors are manufactured using a Grade 5 bolt. They are plated with a commercial bright zinc finish and have a supplementary chromate treatment in accordance with ATM pecification B 633, CI, Type III (Fe/Zn 5). CAT. DRILL MIN. TD. TD. WT./ NO. IZE DIA. EMBED BOX CTN. 100 6900 1/4" x 1" 1/4" 7/8" 100 600 2 6902 1/4" x 1-3/4" 1/4" 1-1/4" 100 600 3 6906 1/4" x 3" 1/4" 1-1/4" 100 600 5 6907 5/16" x 1-3/4" 5/16" 1-1/2" 100 600 5 6908 5/16" x 2-1/2" 5/16" 1-1/2" 50 300 6 6909 5/16" x 3-1/2" 5/16" 1-1/2" 50 300 8 6910 3/8" x 2-1/4" 3/8" 2" 50 300 8 6911* 3/8" x 1-7/8 " 3/8" 1-1/4" 100 600 6 6913 3/8" x 3" 3/8" 2" 50 300 11 6914 3/8" x 3-1/2" 3/8" 2" 50 300 12 6916 3/8" x 4" 3/8" 2" 50 300 14 6930 1/2" x 2-3/4" 1/2" 2-1/2" 50 200 16 6932 1/2" x 3-3/4" 1/2" 2-1/2" 25 150 21 6934 1/2" x 4-3/4" 1/2" 2-1/2" 25 150 26 6936 1/2" x 5-3/4" 1/2" 2-1/2" 25 150 32 6940 5/8" x 3" 5/8" 2-3/4" 20 120 28 6942 5/8" x 4" 5/8" 2-3/4" 15 90 40 6944 5/8" x 5" 5/8" 2-3/4" 15 90 47 6945 5/8" x 6" 5/8" 2-3/4" 15 90 57 6947 5/8" x 8-1/2" 5/8" 2-3/4" 10 40 77 6950 3/4" x 3-1/4" 3/4" 3" 15 90 47 6952 3/4" x 4-1/4" 3/4" 3" 10 60 58 6954 3/4" x 5-1/4" 3/4" 3" 10 60 70 6956 3/4" x 7-1/4" 3/4" 3" 10 40 105 6957 3/4" x 8-1/4" 3/4" 3" 10 40 110 6970 1" x 6" 1" 4-1/4" 10 90 170 6971 1" x 7" 1" 4-1/4" 10 90 195 6974 1-1/4" x 7" 1-1/4" 6" 5 15 290 6975 1-1/4" x 9" 1-1/4" 6" 5 15 360 The published length is measured from below the washer to the end of the anchor. * This size does not have a compression ring. CARBON TEEL FLAT HEAD POWER-BOLT The flat head Power-Bolt anchor has a hex key insert formed in the head of the bolt. Each box contains an allen wrench which matches the insert size. CAT. DRILL MIN. TD. TD. WT./ NO. IZE DIA. EMBED BOX CTN. 100 6981 3/8" x 3-3/4" 3/8" 2" 50 300 14 6982 3/8" x 5" 3/8" 2" 50 300 17 6983 3/8" x 6" 3/8" 2" 50 300 20 6984 1/2" x 5" 1/2" 2-1/2" 25 150 26 6987 5/8" x 5-1/2" 5/8" 2-3/4" 15 90 57 The published length is the entire length of the anchor measured end to end. TAINLE TEEL HEX HEAD POWER-BOLT tainless steel Power-Bolt anchors are manufactured from 300 series stainless steel (passivated). CAT. DRILL MIN. TD. TD. WT./ NO. IZE DIA. EMBED BOX CTN. 100 5900 1/4" x 1" 1/4" 7/8" 100 600 2 5902 1/4" x 1-3/4" 1/4" 1-1/4" 100 600 3 5906 1/4" x 3" 1/4" 1-1/4" 100 600 5 5910 3/8" x 2-1/4" 3/8" 2" 50 300 10 5914 3/8" x 3-1/2" 3/8" 2" 50 300 12 5916 3/8" x 4" 3/8" 2" 50 300 14 5930 1/2" x 2-3/4" 1/2" 2-1/2" 50 200 16 5934 1/2" x 4-3/4" 1/2" 2-1/2" 25 150 26 5944 5/8" x 5" 5/8" 2-3/4" 15 90 47 5946 5/8" x 7" 5/8" 2-3/4" 15 60 67 5954 3/4" x 5-1/4" 3/4" 3" 15 60 70 5957 3/4" x 8-1/4" 3/4" 3" 10 40 110 The published length is measured from below the washer to the end of the anchor. INTALLATION PECIFICATION CARBON TEEL HEX HEAD POWER-BOLT IZE 1/4" 5/16" 3/8" 1/2" ANI Drill Bit ize 1/4" 5/16" 3/8" 1/2" Fixture Clearance Hole 5/16" 3/8" 7/16" 9/16" Internal Bolt ize 10-24 1/4-20 5/16-18 3/8-16 Head Height 7/64" 11/64" 13/64" 15/64" Washer O.D. 1/2" 5/8" 13/16" 1" Wrench ize 5/16" 7/16" 1/2" 9/16" IZE 5/8" 3/4" 1" 1-1/4" ANI Drill Bit ize 5/8" 3/4" 1" 1-1/4" Fixture Clearance Hole 11/16" 13/16" 1-1/8" 1-3/8" Internal Bolt ize 1/2-13 5/8-11 3/4-10 1-8 Head Height 5/16" 25/64" 1/2" 43/64" Washer O.D. 1-1/4" 1-1/2" 1-7/8" 2-3/8" Wrench ize 3/4" 15/16" 1-1/8" 1-1/2" CARBON TEEL FLAT HEAD POWER-BOLT IZE 3/8" 1/2" 5/8" ANI Drill Bit ize 3/8" 1/2" 5/8" Fixture Clearance Hole 7/16" 9/16" 11/16" Internal Bolt ize 5/16-18 3/8-16 1/2-13 Head Width 3/4" 7/8" 1-1/8" Head Height 15/64" 1/4" 21/64" Allen Wrench ize 7/32" 5/16" 3/8" TAINLE TEEL HEX HEAD POWER-BOLT IZE 1/4" 3/8" 1/2" 5/8" 3/4" ANI Drill Bit ize 1/4" 3/8" 1/2" 5/8" 3/4" Fixture Clearance Hole 5/16" 7/16" 9/16" 11/16" 13/16" Internal Bolt ize 10-24 5/16-18 3/8-16 1/2-13 5/8-11 Head Height 7/64" 13/64" 15/64" 5/16" 25/64" Washer O.D. 1/2" 13/16" 1" 1-1/4" 1-1/2" Wrench ize 5/16" 1/2" 9/16" 3/4" 15/16" www.powers.com

60 MATERIAL PECIFICATION COMPONENT MATERIAL CARBON CARBON TAINLE COMPONENT TEEL TEEL TEEL HEX HEAD FLAT HEAD HEX HEAD Internal Bolt Grade 5 Grade 5 *Type 304 Washer AII 1040 N/A Type 18-8 Expansion leeve AII 1010 AII 1010 Type 304 Extension leeve AII 1010 AII 1010 Type 304 Expansion Cone AII 12L14 AII 12L14 Type 303 Compression Ring Nylon Nylon Nylon Dust Cap Nylon Nylon Nylon Plating ATM B 633, C1, Type III (Fe/Zn 5) N/A *Manufactured with a minimum yield strength of 65,000 psi. PERFORMANCE DATA The following load capacities are based on testing conducted according to ATM tandard E 488. ULTIMATE LOAD CAPACITIE - CONCRETE - CARBON TEEL EMBED. 2,000 PI CONCRETE 4,000 PI CONCRETE 6,000 PI CONCRETE IZE DEPTH TORQUE TENION HEAR TENION HEAR TENION HEAR (IN) (IN) (FT-LB) (LB) (LB) (LB) (LB) (LB) (LB) 1/4 7/8 3-4 1,275 1,480 1,445 1,690 1,650 1,690 1/4 1-1/4 3-4 1,975 2,070 2,380 2,130 2,450 2,130 1/4 1-3/4 3-4 1,975 2,110 2,380 2,540 2,450 2,540 1/4 2 3-4 2,230 2,110 2,380 2,825 2,450 2,825 1/4 2-1/2 3-4 2,300 2,110 2,400 3,385 2,500 3,385 5/16 1-1/2 10-15 2,320 2,800 2,540 3,200 2,620 3,200 5/16 2 10-15 2,640 3,280 3,120 4,230 3,270 4,230 5/16 3 10-15 3,280 4,240 3,780 5,380 4,260 5,380 3/8 2 25-35 3,895 4,980 4,585 6,425 5,920 7,875 3/8 2-1/2 25-35 4,200 4,980 4,870 7,160 6,670 7,960 3/8 3-1/2 25-35 4,400 4,980 6,150 8,660 7,550 8,770 1/2 2-1/2 45-60 5,380 8,545 7,325 9,675 7,485 9,675 1/2 3 45-60 7,325 10,150 9,780 10,690 9,830 12,005 1/2 3-1/2 45-60 7,745 10,150 10,245 10,690 10,775 12,005 1/2 5 45-60 8,060 11,930 10,855 12,320 11,460 12,320 5/8 2-3/4 80-100 6,560 9,960 8,440 14,965 9,250 15,005 5/8 3 80-100 6,665 10,980 9,905 16,580 11,135 17,065 5/8 4 80-100 7,085 14,065 10,950 19,290 13,110 20,540 5/8 6 80-100 10,200 19,545 13,665 20,895 16,955 22,055 3/4 3 95-120 10,460 18,170 10,475 20,140 10,780 20,140 3/4 4 95-120 11,545 22,935 12,345 26,525 12,840 29,795 3/4 4-1/2 95-120 12,075 24,055 13,575 27,615 17,330 30,350 3/4 5 95-120 12,610 25,175 15,700 28,705 18,050 30,905 3/4 7 95-120 14,170 29,725 18,210 33,125 24,070 33,155 1" 4-1/4 185-200 14,800 30,000 20,400 35,600 25,500 40,800 1" 5 185-200 16,200 35,200 21,800 38,400 26,900 42,000 1" 6 185-200 18,300 37,000 24,200 40,000 28,600 42,000 1-1/4 6 350-375 24,600 53,200 33,800 63,400 43,800 74,800 1-1/4 7 350-375 27,440 57,800 35,500 66,800 45,600 77,000 1-1/4 8 350-375 30,000 60,000 38,000 70,000 48,120 77,000 ULTIMATE LOAD CAPACITIE - CONCRETE - TAINLE TEEL EMBED. 2,000 PI CONCRETE 4,000 PI CONCRETE 6,000 PI CONCRETE IZE DEPTH TORQUE TENION HEAR TENION HEAR TENION HEAR (IN) (IN) (FT-LB) (LB) (LB) (LB) (LB) (LB) (LB) 1/4 7/8 3-4 1,275 1,480 1,445 1,690 1,650 1,690 1/4 1-1/4 3-4 1,760 2,070 1,760 2,130 1,760 2,130 1/4 1-3/4 3-4 1,760 2,110 1,760 2,540 1,760 2,540 1/4 2 3-4 1,760 2,110 1,760 2,825 1,760 2,825 1/4 2-1/2 3-4 1,975 2,110 1,975 3,385 1,975 3,385 3/8 2 15-20 3,895 4,980 4,585 6,425 5,920 7,875 3/8 2-1/2 15-20 4,200 4,980 4,870 7,160 6,670 7,960 3/8 3-1/2 15-20 4,400 4,980 6,150 8,660 6,900 8,770 1/2 2-1/2 25-35 5,380 8,545 7,325 9,675 7,485 9,675 1/2 3 25-35 7,325 10,150 9,480 10,690 9,480 10,690 1/2 3-1/2 25-35 7,745 10,150 10,245 10,690 10,775 12,005 1/2 4-1/4 25-35 7,900 11,040 10,550 11,505 11,115 12,160 5/8 2-3/4 45-60 6,560 9,960 8,440 14,965 9,250 15,005 5/8 3 45-60 6,665 10,980 9,905 16,580 11,135 17,065 5/8 4 45-60 7,085 14,065 10,950 19,290 13,110 20,540 5/8 6 45-60 10,200 19,545 13,470 20,895 15,000 22,055 3/4 3 70-90 10,460 18,170 10,475 20,140 10,780 20,140 3/4 4 70-90 11,545 22,935 12,345 26,525 12,840 26,525 3/4 4-1/2 70-90 12,075 24,055 13,575 27,615 14,570 27,615 3/4 5 70-90 12,610 25,175 14,680 28,705 16,300 28,705 3/4 7 70-90 14,170 29,040 16,540 29,040 20,120 29,040 NOTE: The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4 or greater to determine the allowable working load. ULTIMATE LOAD CAPACITIE - LIGHTWEIGHT CONCRETE 2000 PI LIGHTWEIGHT CONCRETE EMBED. TORQUE TENION HEAR 1/4 1-1/4" 4 1,190 1,480 1/4 2" 4 1,510 1,540 3/8 2" 20 2,920 3,830 3/8 3-1/2" 20 4,200 4,980 1/2 2-1/2" 35 3,280 7,120 1/2 5" 35 5,540 8,730 5/8 2-3/4" 60 4,830 11,300 5/8 6" 60 6,730 14,340 3/4 3" 85 7,320 13,790 3/4 7" 85 9,860 19,740 NOTE: The values listed above are ultimate load capacities for both the carbon and stainless steel Power-Bolt anchors which should be reduced by a minimum safety factor of 4 or greater to determine the allowable working load.

61 ULTIMATE LOAD CAPACITIE - C-90 BLOCK AND BRICK C-90 HOLLOW BLOCK EMBED. TORQUE TENION HEAR 1/4 7/8 4 1,030 1,320 1/4 1-1/2 4 1,410 1,540 3/8 1-1/2 20 1,840 3,250 1/2 1-1/2 35 2,530 4,230 OLID RED BRICK EMBED. TORQUE TENION HEAR 1/4 7/8 5 1,360 1,450 1/4 1-1/2 5 1,820 1,580 3/8 2 30 2,520 4,570 1/2 2-1/2 50 3,890 5,730 5/8 2-3/4" 80 5,670 6,840 3/4 3" 100 7,410 8,460 NOTE: The values listed above are ultimate load capacities for both the carbon steel and stainless steel Power-Bolt anchors. Depending upon anchor application and governing building code, ultimate load capacities should be reduced by a minimum safety factor of 4 or greater to determine the allowable working load. The design professional familiar with the actual product installation should be consulted. Please refer to the general section entitled Evaluation of Test Data that appears earlier in this manual for current industry standards. The consistency of hollow block or brick varies greatly. The load capacities listed above should be used as guidelines only. Job site tests should be conducted to verify base material consistency, proper installation torque values and actual anchor performance. The 1/2" size will consistently fail hollow block. The 5/8" or 3/4" sizes can be used, but the ultimate capacities will be no higher than those for the 1/2" size. ULTIMATE LOAD CAPACITIE - GROUT FILLED C-90 HOLLOW BLOCK GROUT FILLED BLOCK EMBED. TORQUE TENION HEAR 1/4 1-1/8" 4 1,520 1,480 1/4 2-1/2" 4 2,200 1,480 3/8 2" 20 2,480 3,830 3/8 3-1/2" 20 2,650 3,830 1/2 2-1/2" 35 3,045 7,060 1/2 4" 35 3,360 7,060 5/8 2-3/4" 60 3,200 11,250 5/8 5" 60 3,720 11,250 3/4 3" 85 4,180 12,340 3/4 5" 85 5,310 12,340 NOTE: The values listed above are ultimate load capacities for both the carbon and stainless steel Power-Bolt anchor. Depending upon anchor application and governing building code, ultimate load capacities should be reduced by a minimum safety factor of 4 or greater to determine the allowable working load. The design professional familiar with the actual product installation should be consulted. Please refer to the general section entitled Evaluation of Test Data that appears earlier in this manual for current industry standards. The consistency of grout filled block varies greatly. The load capacities listed above should be used as guidelines only. Job site tests should be conducted to verify base material consistency, proper installation torque values and actual anchor performance. DEIGN CRITERIA E D = Anchor ize = pacing E = Edge Distance BMT = Base Material Thickness BAE MATERIAL THICKNE The minimum recommended thickness of solid base material, BMT, when using the Power-Bolt anchor is 125% of the embedment to be used. For example, when installing an anchor to a depth of 4", the base material thickness should be 5". This does not apply to the thickness of the face shell in a hollow block wall. PACING BETWEEN To obtain the maximum load in tension or shear, a spacing,, of 10 anchor diameters (10D) or greater should be used. The minimum recommended anchor spacing,, is 5 anchor diameters (5D) at which point the load should be reduced by 50%. Anchor spacing closer or less than 5 diameters (5D) needs to be field tested. Actual base material conditions will determine any applicable reduction factor. The following table lists the load reduction factor, Rs, for each anchor diameter, D, based on the center to center anchor spacing. PACING, (INCHE) IZE TENION AND HEAR D 10D 9D 8D 7D 6D 5D 1/4 2-1/2 2-1/4 2 1-3/4 1-1/2 1-1/4 5/16 3-1/8 2-7/8 2-1/2 2-1/4 1-7/8 1-5/8 3/8 3-3/4 3-3/8 3 2-5/8 2-1/4 1-7/8 1/2 5 4-1/2 4 3-1/2 3 2-1/2 5/8 6-1/4 5-5/8 5 4-3/8 3-3/4 3-1/8 3/4 7-1/2 6-3/4 6 5-1/4 4-1/2 3-3/4 1 10 9 8 7 6 5 1-1/4 12-1/2 11-1/4 9 8-3/4 7-1/2 6-1/4 Rs 1.00 0.90 0.80 0.70 0.60 0.50 EDGE DITANCE - TENION For tension loads, an edge distance, E, of 12 diameters (12D) or greater should be used to obtain the maximum tension load. The minimum recommended edge distance, E, is 5 diameters (5D) at which point the tension load should be reduced by 20%. Edge distances closer or less than 5 diameters (5D) need to be field tested. Actual base material conditions will determine any applicable E D BMT www.powers.com

62 reduction factor. The following table lists the load reduction factor, Re, for each anchor diameter, D, based on the anchor center to edge distance. EDGE DITANCE, E (INCHE) IZE TENION ONLY D 12D 11D 10D 9D 8D 7D 6D 5D 1/4 3 2-3/4 2-1/2 2-1/4 2 1-3/4 1-1/2 1-1/4 5/16 3-3/4 3-1/2 3-1/8 2-7/8 2-1/2 2-1/4 1-7/8 1-5/8 3/8 4-1/2 4-1/8 3-3/4 3-3/8 3 2-5/8 2-1/4 1-7/8 1/2 6 5-1/2 5 4-1/2 4 3-1/2 3 2-1/2 5/8 7-1/2 6-7/8 6-1/4 5-5/8 5 4-3/8 3-3/4 3-1/8 3/4 9 8-1/4 7-1/2 6-3/4 6 5-1/4 4-1/2 3-3/4 1 12 11 10 9 8 7 6 5 1-1/4 15 13-1/4 12-1/2 11-1/4 9 8-3/4 7-1/2 6-1/4 Re 1.00 0.97 0.94 0.91 0.89 0.86 0.83 0.80 EDGE DITANCE - HEAR For shear loads, an edge distance, E, of 12 anchor diameters (12D) or greater should be used to obtain the maximum load. The minimum recommended edge distance, E, is 5 anchor diameters (5D) at which point the shear load should be reduced by 50%. Edge distances closer or less than 5 diameters (5D) need to be field tested. Actual base material conditions will determine any applicable reduction factor. The following table lists the load reduction factor, Re, for each anchor diameter, D, based on the anchor center to edge distance. EDGE DITANCE, E (INCHE) IZE HEAR ONLY D 12D 11D 10D 9D 8D 7D 6D 5D 1/4 3 2-3/4 2-1/2 2-1/4 2 1-3/4 1-1/2 1-1/4 5/16 3-3/4 3-1/2 3-1/8 2-7/8 2-1/2 2-1/4 1-7/8 1-5/8 3/8 4-1/2 4-1/8 3-3/4 3-3/8 3 2-5/8 2-1/4 1-7/8 1/2 6 5-1/2 5 4-1/2 4 3-1/2 3 2-1/2 5/8 7-1/2 6-7/8 6-1/4 5-5/8 5 4-3/8 3-3/4 3-1/8 3/4 9 8-1/4 7-1/2 6-3/4 6 5-1/4 4-1/2 3-3/4 1 12 11 10 9 8 7 6 5 1-1/4 15 13-1/4 12-1/2 11-1/4 9 8-3/4 7-1/2 6-1/4 Re 1.00 0.93 0.86 0.79 0.71 0.64 0.57 0.50 UGGETED PECIFICATION CARBON TEEL HEX HEAD POWER-BOLT Carbon steel expansion anchors shall be a pre-assembled heavy duty sleeve style, self-undercutting anchor with a Grade 5 hex head internal bolt. The anchors shall have a nylon compression ring and an expansion cone with an oversized annular ring which expands to undercut the base material. Carbon steel components shall be plated according to ATM pecification B 633, C1, Type III (Fe/Zn 5). Power-Bolt anchors shall be as dimensioned and supplied by Powers Fasteners Inc. CARBON TEEL FLAT HEAD POWER-BOLT Carbon steel expansion anchors shall be a pre-assembled heavy duty sleeve style, self-undercutting anchor with a Grade 5 flat head internal bolt. The anchors shall have a nylon compression ring and an expansion cone with an oversized annular ring which expands to undercut the base material. Carbon steel components shall be plated according to ATM pecification B 633, C1, Type III (Fe/Zn 5). Power-Bolt anchors shall be as dimensioned and supplied by Powers Fasteners Inc. TAINLE TEEL POWER-BOLT tainless steel expansion anchors shall be a pre-assembled heavy duty sleeve style, self-undercutting anchor with an internal hex head meeting the requirements of ATM pecification F 593. The anchors shall have a nylon compression ring and an expansion cone with an oversized annular ring which expands to undercut the base material. The steel components shall be manufactured from Type 303 or 304 stainless steel. Power-Bolt anchors shall be as dimensioned and supplied by Powers Fasteners Inc. APPROVAL AND LITING The following approvals and listings are for reference purposes. They should be reviewed by the design professional responsible for the product installation to verify approved base materials, sizes, and compliance with local codes. ICBO E Evaluation Report No. 5225 COLA Research Report No. 24960 BCCI Report No. 9943 Factory Mutual Research Corporation J.I. 1K8A3.AH Underwriters Laboratories File No. EX 1289 (N) Metro-Dade pending Federal pecification Meets the proof load requirements of FF--325C, Group II, Type 3, Class 3 (superceded)