Operating instructions Diffuse reflection sensor with background suppression. OJ51xx laser / / 2010

Similar documents
Operating instructions Contrast sensor O5K / / 2016

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2009

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2018

Operating instructions optical fork sensor OPU200 OPU200 / / 2018

Optical laser distance sensors. Dimensioned drawing

Laser light scanner with background suppression. Dimensioned drawing

PHOTOELECTRIC SENSORS. Online data sheet

QL50 Luminescence Sensor

MLV12 Series Dura-Vue TM Sensors

Installation instructions for encoders. RM3xxx RM7xxx RN3xxx RN7xxx /02 08/2015

MLV40 Series Miniature Sensors

in one housing (3). The light beam is reflected by a reflector (4). The objects are detected by interruption of the light beam.

QL55 Series Luminescence Sensor

Laser contrast scanner. Dimensioned drawing

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Operating instructions Magnetic-inductive flow meter FMM FMM FMM

User Manual Laser distance sensor. series OWLE. Welotec GmbH Zum Hagenbach Laer Manual_OWLE _EN 1/20

Installation Instructions RF-identification system Read/write head DTM434 DTM435 DTM436 DTM437

Operating instructions Magnetic-inductive flow meter SM6050 SM7050 SM / / 2016

Operating instructions Magnetic-inductive flow meter FMM FMM FMM

Parallel Beam Linear Sensor

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Installation Instructions RF identification system Read/write head ANT430 ANT431

WORLD-BEAM QS30AF Sensor

Operating instructions PMD 3D sensor. O3D2xx /02 04 / 2015

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Distance Sensors BOD 26K.... with optional Master-Slave-Mode

Operating instructions Measured signal converter for temperature sensors TP / / 2010

Technical data. General specifications. Transducer frequency Indicators/operating means

laser sensors through-beam sensor switching output / analog output high precision repeatability

Laser Photoelectric Sensor

Online data sheet. RT-P3221 ZoneControl PHOTOELECTRIC SENSORS

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Diffuse reflection light scanner with background suppression. Dimensioned drawing

W 23-2: Focussing on what is essential and economic

Technical data. General specifications. Transducer frequency Indicators/operating means

Optical laser distance sensors. Dimensioned drawing

Ultrasonic sensors. Reliable on almost all surfaces. UT 20 from Page 548. UT 12 from Page 564. UT/UM 18 from Page 568

Built-in Amplifier Photoelectric Sensor

SPECIFICATIONS Type Catalog listing Power supply Consumption current Detecting distance Focal distance Focal spot diameter Operation mode

Laser Photoelectric Sensor

Installation Instructions RF-identification system Read/write head ANT513

Original operating instructions Fail-safe inductive sensor GM705S

Operating instructions Electronic level sensor LK / / 2008

Operating instructions. Electronic pressure sensor PY2068 ENGLISH

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R

Online data sheet VT12T-2P410 V12-2 CYLINDRICAL PHOTOELECTRIC SENSORS

Electrical connection

Industry's standard of transparent object detection sensor

Original operating instructions Fail-safe inductive sensor GG507S

Operating instructions. Combined pressure sensor PN /00 11/03

P10 LASER DISTANCE MEASURE. IMPORTANT: Read before Using

Contrast scanners detect the little differences

Contrast Sensors. SICK The pioneer in contrast sensors for more than 60 years

Ultraminiature Photoelectric Switches with Self-contained Amplifier

CATALOG LISTING SPECIFICATIONS 11 30mA 22 to 130mm (White Paper), 22 to 70mm (Black Paper) 3 to 130mm (White Paper) Ambient light Seal

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

Leuze electronic. 3 Series. Product description

Long Range Metal Body Sensor

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

FEATURES. 15 m ft. 4 m ft. 2 m ft. 100 mm in. 600 mm in. 15 m ft. 4 m ft. 2 m ft. 100 mm 3.

Online data sheet. WLG190T-P420 W190 Laser High Grade Glass PRODUCT PORTFOLIO

V 18 Laser No frills performance: long ranges, high speeds with precision

Operating instructions Measured signal converter for temperature sensors. TP323x / / 2010

Distance sensors. System description. Distance measurement using triangulation

Q4X Stainless Steel Laser Sensor

Laser LA-4P. Operating instructions

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

Product description. At a glance. IP 69K-rated cylindrical photoelectric sensors in M18 stainless steel housing Resistant to all common cleaning

A finger on the pulse of time

Throughbeam photoelectric sensors. Dimensioned drawing. Transmitter/receiver Optical axis LED yellow 90 turning connector. Electrical connection

Analog Laser Sensor. Installation Instructions. Specifications. Summary of Changes. Description. Catalog Numbers 45BPD-8LTB1-D5, 45BPD-8LTB2-D5

5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication

5-step-switch for adjustment of sensitivity (switching threshold) LED (super-bright, yellow) for switching state indication.

Online data sheet. WTR2-P521 ZoneControl PHOTOELECTRIC SENSORS

Online data sheet VT12T-2N112 V12-2 CYLINDRICAL PHOTOELECTRIC SENSORS

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Electrical connection

Photoelectric Series 28 Rectangular

SLE30 Expert Series Teach-Mode Slot Sensor

Online data sheet WT34-B410 W34 PRODUCT PORTFOLIO

Distance sensors. System description. Distance measurement using triangulation

Operating instructions. RFID UHF reader DTE800 DTE810 DTE900 DTE910 DTE / / 2017

Online data sheet. WTB4S-3P1132V W4S-3 Inox MINIATURE PHOTOELECTRIC SENSORS

M12 Class 1 Laser Emitter

Online data sheet VL18-4N3112 V18 PRODUCT PORTFOLIO

M18 DC Photoelectric Switches FA

M18 Plastic. Photoelectric Standard Sensors BOS 18KF Global

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Operating instructions. RFID UHF antennas Low range / ultra-low range Mid range / short mid range Wide range

Online data sheet. WTB190TL-P460 W190 Laser High Grade PRODUCT PORTFOLIO

Operating instructions Electronic level sensor LK31xx

D-LAS Series D-LAS2-LC-... Design. D-LAS Series Laser Digital Light Barriers. Product name: Transmitter: D-LAS2-LC-T.

L-GAGE LT3 SENSORS. LT3 Sensing Ranges QPMA LIGHT GAUGING ULTRASONIC MEASURING ARRAYS RADAR. More information online at bannerengineering.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

USi Product Presentation. Mayser Ultrasonic Industrial Sensor USi

Online data sheet WSE9LC-3P2436A00 W9L-3

Miniature photoelectric switches series W4-3: The efficient space savers

D-LAS Series D-LAS2-... Design. D-LAS Series Laser Digital Light Barriers. Product name: Transmitter: D-LAS2-(aperture)*-T

Transcription:

Operating instructions Diffuse reflection sensor with background suppression OJ51xx laser 704811 / 00 05 / 2010

Contents 1 Preliminary note3 1.1 Symbols used 3 2 Safety instructions 3 3 Functions and features 4 4 Installation 4 4.2 Mounting positions 5 5 Electrical connection5 6 Settings6 6.1 Setting of the sensitivity with stationary objects* 6 6.2 Setting of the maximum sensitivity* 7 6.3 Electronic lock 7 6.4 Programming the output function* 7 7 Operation 8 8 Maintenance, repair and disposal8 2

1 Preliminary note 1.1 Symbols used Instruction > Reaction, result Cross-reference Important note Non-compliance can result in malfunctions or interference. Information Supplementary note. 2 Safety instructions According to the culus approval Caution - Use of controls or adjustments or procedures other than those specified herein may result in hazardous radiation exposure. Visible laser light; CLASS 1 LASER PRODUCT. IEC 60825-1 : 2007 Complies with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated June 2007. Position of the product label Additional label Example OJ5152 3

3 Functions and features The diffuse reflection sensor detects objects and materials without contact and indicates their presence by a switching signal. Range: type label (on white paper 200 mm x 200 mm). 4 Installation Side lens* Front lens* 2 1 2 1 1: 2: LED pushbutton * In the following sections installation and setup are described using the example of the type with front lens. The functions of the units with side lens are identical. Align the diffuse reflection sensor to the object to be detected and secure it to a bracket. Maximum range is only possible with precise alignment. Mount the unit so that the mounting position cannot change (avoid high vibrations!). Laser units with a very small light spot diameter are highly focussed; the slightest change in the mounting position will result in misalignment. The optical position of the laser beam may deviate slightly from the mechanical axis. Therefore we recommend using the fine adjustment units E21225 (front lens) or E21226 (side lens) when mounting the laser units. The objects to be detected are to move transversally to the lens of the sensor. In case of other directions of movement it should be tested before whether safe switching is guaranteed. 4

4.2 Mounting positions For demanding applications (small distance between the object and the background) we recommend the following mounting positions: Reflective background In case of highly reflective background surfaces and less reflective object surfaces the sensor should be mounted vertically to the background surface. Reflective object In case of highly reflective object surfaces and less reflective background surfaces the sensor should be mounted at an angle of approx. 5 to 10. 5 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Voltage supply according to EN 50178. Disconnect power. Connect the unit as follows: DC PNP 1 2 4 3 L+ teach L Programming of the output function by pushbutton or programming wire ( 6.4 Programming the output function). 5

6 Settings 6.1 Setting of the sensitivity with stationary objects* Go into the programming mode of the unit. 1 Press for about 2 s until the red LED flashes. The red LED goes out; the yellow and green LEDs flash alternately. The unit is in the programming mode. Set the sensitivity with object. 2 Press once. The yellow and green LEDs go out for approx. 1 s, then flash again alternately. Set the sensitivity without object. Press once. 3 The yellow and green LEDs go out for approx. 1 s. After approx. 3 s the green LED is on. The unit is in the operating mode. Setting steps 2 and 3 can also be carried out in reverse order. * The sensitivity can also be set in exactly the same way using the programming wire (pin 2 / WH). To activate the functions the programming wire is connected to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time. Feedback: If setting was not successful via the programming wire, the output will switch for 2 s. The unit then passes into the operating mode with the sensitivity being unchanged. 6

If the setting of the sensitivity is not possible (e.g. object signal and background signal are about the same), the red LED flashes after step 3 for approx. 2 s. The unit then passes into the operating mode with the sensitivity being unchanged. If the setting button is not activated for 15 minutes during the programming process, the unit passes automatically into the operating mode with the sensitivity being unchanged. 6.2 Setting of the maximum sensitivity* Go into the programming mode of the unit. ( step 1). Align the unit so that no light is reflected (min. distance > max. range). Press the setting button twice ( steps 2 and 3). * The maximum sensitivity can also be set in exactly the same way using the programming wire (pin 2 / WH). To activate the functions the programming wire is connected to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time. 6.3 Electronic lock Activate the lock by connecting the programming wire for about 15 s -20 s*. De-activate the lock by connecting the programming wire again for 15 s - 20 s*. * To activate the functions the programming wire (pin 2 / WH) is connected to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time. 6.4 Programming the output function* Press for 10 s. The red LED starts to flash fast after 2 s. Then the yellow and green LEDs flash alternately. After 10 s all LEDs go off, the output function has changed from light-on mode to dark-on mode (or vice versa). * The output function can be programmed in exactly the same way using the programming wire (pin 2 /WH). To activate the functions the programming wire is connected to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time. 7

7 Operation Check whether the unit operates correctly. Display by LEDs. Green LED on Yellow LED on LEDs yellow + red Unit is ready for operation. Output is switched. Flash alternately, 2 Hz: output short-circuited. Flash alternately, 1 Hz: internal fault. (output is not switched). 8 Maintenance, repair and disposal Keep the lenses of the sensor free from soiling. For cleaning do not use any solvents or cleaning agents which could damage the plastic lenses. Do not try to open the module enclosure. There are no user - serviceable components inside. Technical data and further information at www.ifm.com Select your country Data sheet direct: 8

9