Electronics I. laboratory measurement guide Andras Meszaros, Mark Horvath

Similar documents
Electronics I. laboratory measurement guide

Basic DC Power Supply

Figure 1: Diode Measuring Circuit

Figure 1: Diode Measuring Circuit

EXPERIMENT 5 : THE DIODE

SKEU 3741 BASIC ELECTRONICS LAB

EXPERIMENT 3 Half-Wave and Full-Wave Rectification

Diodes. Diodes, Page 1

Electronics I. laboratory measurement guide

EXPERIMENT 5 : THE DIODE

transformer rectifiers

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

Power supply circuits

EXPERIMENT 5 : THE DIODE

Lab 2: Linear and Nonlinear Circuit Elements and Networks

EE 2212 EXPERIMENT 3 3 October 2013 Diode I D -V D Measurements and Half Wave and Full Wave Bridge Rectifiers PURPOSE

EXPERIMENT NUMBER 4 Examining the Characteristics of Diodes

EXPERIMENT 7: DIODE CHARACTERISTICS AND CIRCUITS 10/24/10

Dev Bhoomi Institute Of Technology Department of Electronics and Communication Engineering PRACTICAL INSTRUCTION SHEET

EXPERIMENT 5 : DIODES AND RECTIFICATION

Sept 13 Pre-lab due Sept 12; Lab memo due Sept 19 at the START of lab time, 1:10pm

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab

LABORATORY MODULE. Analog Electronics. Semester 2 (2005/2006)

UNIVERSITY OF TECHNOLOGY, JAMAICA SCHOOL OF ENGENEERING. Electrical Engineering Science. Laboratory Manual

Sirindhorn International Institute of Technology Thammasat University at Rangsit

Electronics 1 Lab (CME 2410)

Power Electronics Laboratory-2 Uncontrolled Rectifiers

EE 110 Introduction to Engineering & Laboratory Experience Saeid Rahimi, Ph.D. Lab 6 Diodes: Half-Wave and Full-Wave Rectifiers Converting AC to DC

Diodes This week, we look at switching diodes, LEDs, and diode rectification. Be sure to bring a flash drive for recording oscilloscope traces.

Diode Applications Half-Wave Rectifying

3. Diode, Rectifiers, and Power Supplies

Experiment #2 Half Wave Rectifier

Power supply circuits

UNIVERSITY OF NORTH CAROLINA AT CHARLOTTE. Department of Electrical and Computer Engineering

Industrial Electricity. Answer questions and/or record measurements in the spaces provided.

Electronic Circuits I Laboratory 03 Rectifiers

Laboratory 2 (drawn from lab text by Alciatore)

UNIVERSITY OF TECHNOLOGY, JAMAICA School of Engineering -

Figure 1 Diode schematic symbol (left) and physical representation (right)

After performing this experiment, you should be able to:

ECE 2274 Diode Basics and a Rectifier Completed Prior to Coming to Lab

Circuit operation Let s look at the operation of this single diode rectifier when connected across an alternating voltage source v s.

Electronics II. 3. measurement : Tuned circuits

DEPARTMENT OF ELECTRICAL ENGINEERING LAB WORK EE301 ELECTRONIC CIRCUITS

Purpose: 1) to investigate the electrical properties of a diode; and 2) to use a diode to construct an AC to DC converter.

Sheet 2 Diodes. ECE335: Electronic Engineering Fall Ain Shams University Faculty of Engineering. Problem (1) Draw the

Electric Circuit Fall 2017 Lab3 LABORATORY 3. Diode. Guide

EXPERIMENT 1 PRELIMINARY MATERIAL

Physics 310 Lab 4 Transformers, Diodes, & Power Supplies

LABORATORY 8 DIODE CIRCUITS

The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope.

EE 462: Laboratory # 4 DC Power Supply Circuits Using Diodes

PHY 351/651 LABORATORY 5 The Diode Basic Properties and Circuits

Lab 2: Diode Characteristics and Diode Circuits

Sirindhorn International Institute of Technology Thammasat University at Rangsit

2) The larger the ripple voltage, the better the filter. 2) 3) Clamping circuits use capacitors and diodes to add a dc level to a waveform.

Başkent University Department of Electrical and Electronics Engineering EEM 214 Electronics I Experiment 2. Diode Rectifier Circuits

EE 368 Electronics Lab. Experiment 10 Operational Amplifier Applications (2)

Exercise 6. The Boost Chopper EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. The boost chopper

ECEG 350L Electronics I Laboratory Fall 2017

PHYS 3152 Methods of Experimental Physics I E2. Diodes and Transistors 1

Laboratory 2. Lab 2. Instrument Familiarization and Basic Electrical Relations. Required Components: 2 1k resistors 2 1M resistors 1 2k resistor

1.1 Create in Multisim the circuit shown in Figure 2-1. Make sure to use the AC Voltage source instead of the Power Source as shown in Figure 2-2.

Examples to Power Supply

29:128 Homework Problems

Brown University PHYS 0060 Physics Department LAB B Circuits with Resistors and Diodes

The preferred Exercise is shown in Exercises 5B or 5C.

BME 3512 Bioelectronics Laboratory Five - Operational Amplifiers

Group: Names: Resistor Band Colors Measured Value ( ) R 1 : 1k R 2 : 1k R 3 : 2k R 4 : 1M R 5 : 1M

Physics 4BL: Electricity and Magnetism Lab manual. UCLA Department of Physics and Astronomy

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Lab 11: 555 Timer/Oscillator Circuits

1. An engineer measures the (step response) rise time of an amplifier as. Estimate the 3-dB bandwidth of the amplifier. (2 points)

PHY152 Experiment 4: Oscillations in the RC-Circuits (Measurements with an oscilloscope)

Prepare for this experiment!

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

Exercise 6 AC voltage measurements average responding voltmeters

LAB II. INTRODUCTION TO LAB EQUIPMENT

INTRODUCTION TO ENGINEERING AND LABORATORY EXPERIENCE Spring, 2015

Lab 1 - Analogue and Digital Signals

ECE 2274 Pre-Lab for Experiment # 4 Diode Basics and a Rectifier Completed Prior to Coming to Lab

Uncle Sparky s Guide to Voltage, Current, and Resistance Measurements. Spring 2014

EE351 Laboratory Exercise 4 Field Effect Transistors

Electronics. RC Filter, DC Supply, and 555

ECE Electronics Circuits and Electronics Devices Laboratory. Gregg Chapman

Experiment No.5 Single-Phase half wave Voltage Multiplier

ECE ECE285. Electric Circuit Analysis I. Spring Nathalia Peixoto. Rev.2.0: Rev Electric Circuits I

EE351 Laboratory Exercise 1 Diode Circuits

Federal Urdu University of Arts, Science & Technology Islamabad Pakistan SECOND SEMESTER ELECTRONICS - I

BME/ISE 3512 Bioelectronics. Laboratory Five - Operational Amplifiers

INC 253 Digital and electronics laboratory I

EXPERIMENT 6: THE ZENER DIODE AND REGULATION

EECS 318 Electronics Lab Laboratory #2 Electronic Test Equipment

EE320L Electronics I. Laboratory. Laboratory Exercise #4. Diode Rectifiers and Power Supply Circuits. Angsuman Roy

R 1 R 2. (3) Suppose you have two ac signals, which we ll call signals A and B, which have peak-to-peak amplitudes of 30 mv and 600 mv, respectively.

LAB I. INTRODUCTION TO LAB EQUIPMENT

PHYS 235: Homework Problems

Application of diodes

LAB 1: Familiarity with Laboratory Equipment (_/10)

Experiment 5 The Oscilloscope

Transcription:

Electronics I. laboratory measurement guide Andras Meszaros, Mark Horvath 3. Measurement: Diodes and rectifiers 2017.02.27. In this session we are going to measure forward and reverse characteristics of diodes and the operation of half-wave and full-wave rectifier circuits. This measurement needs asymmetric power supply, that is, a single power supply unit (one of the controllable outputs of the unit). Set up a current limit of 30mA before starting the measurement, and don't change this value throughout the session. The rectifier diode used is type 1N4007. The Zener-diode is type BZX5V1 (with breakdown voltage of 5.1V). Find their connection info in the picture below. As seen, the cathode (K) is usually denoted with a strip on one end of the package. Figure 2.1: Connection of 1N4007 Si diode (left), and of the Zener-diode (right) 2.0 Mandatory homework 1. Calculate the expected current values in exercise 2.1 if the supply voltage is: 2V, 6V, 12V, 18V. Apply the known approximation for the diode forward voltage. 2. Calculate the expected current values in exercise 2.2 if the supply voltage is: 1V, 8V, 12V, 18V. 3. Calculate the expected output voltage of the Graetz-type rectifier in exercise 2.4 if the transformer s secondary voltage is 8Vrms.

2.1 Measurement of forward characteristics of normal Si diode 2.1.1 Build the circuit seen in figure 2.2. This will be used to measure the forward characteristics of the diode. (The reverse characteristics of the normal diode is not measured, because its breakdown voltage can be several hundred volts.) The value of R resistor is 1kΩ. Figure 2.2 Circuit for measuring forward characteristics 2.1.2 Use the current and voltage meters in 3 decimal digit precision setup (the current meter in ma setup, the voltage meter in V setup with 3 digits after the decimal point). The current meter will measure the diode's current (because the voltmeter's internal resistance can be considered infinite relative to the diode's); the voltmeter measures the diode's voltage, these two are needed for the characteristics. The proper setup of the circuit can be tested by setting up a power supply voltage of several volts, in this case the voltage meter should show the forward diode voltage learned in our theoretical studies. The resistor R protects the diode and also allows us to set up the I and V values in higher precision. Fill the following table with measurement data! V 0 [V] 0.3 0.5 0.7 0.9 1.1 1.3 1.5 2 3 4 5 6 8 10 12 14 16 18 V D [mv] I D [ma] 1.0 In the lab report, draw a V D -I D graph with linear scales and draw the forward characteristics. Calculate the reverse current I 0 from the diode equation, use I D and V D values from the forward part where I D >1mA. Using more than one pair of values allows you to average, thereby decreasing the effect of measurement error. 2.1.3* For the last column of the table, try to set up 1mA of diode current as precisely as possible, and measure the voltage in this case. Then, remove the diode and measure it using the multimeter's diode function! (The multimeter uses 1mA current generator to measure the diode, thus the measured voltage should be approximately equal to what you measured with 1mA.)

2.2 Measurement of reverse characteristics of Zener-diode 2.2.1 Build the circuit according to figure 2.3 to measure the Zener-diode BZX5V1. The type name shows us that is has 5.1V breakdown voltage. Therefore we are going to measure in more detail around this value. The circuit is similar to the previous, except the Z-diode is connected in reverse. R is still 1kΩ. (Note that the forward characteristics of Zener-diodes are similar to normal diodes, also these are not used in that region, therefore we are not measuring it in greater detail, only in a few points.) Figure 2.3: Measurement circuit for reverse characteristics of Zener-diodes Though in this setup you are going to measure positive values, please draw the graph in the 3 rd quarter of the coordinate system (that is, negative V and I), as the values are part of the reverse region of the characteristics. V 0 [V] 1 2 3 4 4,5 4,7 4,9 5,1 5,3 5,5 5,7 6 7 8 10 12 14 16 18 V D [V] I D [ma] 2.2.2 Reverse the connection of the Zener-diode. That is, connect it in forward bias! With a quick measurement, prove that the forward characteristics are similar to the normal diode! V 0 [V] 0.5 1 1.5 2 2.5 3 V D [V] I D [ma] Use the previous coordinate system and its 1 st quarter (positive I and V) to draw the forward region!

2.3 Half-wave rectifier circuit In this exercise we won't need the power supply and the multimeters. The input voltage will come from a transformer. This transformer has no on-off button, therefore only connect it when you are certain the circuit is built properly and ready for measurement. Also, when you make any changes in your circuit, first disconnect the input to avoid any accidental short circuits. The waveform of the transformer may not be a perfect sinewave. It is because the ferrite core goes into saturation; the output waveform is distorted. It poses no problem, as our goal is to rectify, that is, to change it to DC (direct current). Absolute ripple is the difference of the maximum and minimum of the output signal. Relative ripple is the absolute ripple divided by the maximum value (that is, normalized), expressed in percentage. Remember that the AC input is usually given as effective value, while for the rectifier the peak value is important. Use the 1N4007 diode in this circuit. Figure 2.4 Half-wave rectifier circuit. 2.3.1 First connect the transformer's output signal to the oscilloscope and note the main parameters of the signal (esp. peak value). 2.3.2 Build the circuit from figure 2.4. The R load resistor s value is 3.6kΩ. Connect the signal V in to channel 1 of the oscilloscope, this is the input of the circuit. Connect V out to channel 2 of the oscilloscope, this is the output. (When using digital oscilloscope, take care to set up Edge mode for the trigger!) First don't connect the C capacitor in the circuit. 2.3.3 Configure the sec/div setting on the scope according to the 50Hz mains frequency (it is practical to set the sec/div timebase to about 1/4 of the period T of the examined signal). Change the V/div setting according to the voltage shown on the transformer. Set both Ch1 and Ch2 channels to DC coupling and set their GND level to the same value. Mesure and draw the signals in your report, with proper relative magnitudes and phases, and explain them. How much lower is the output's peak value than the input's? 2.3.4 Repeat the measurement with the C=2.2µF buffer capacitor in place! Take care of the polarity. Electrolythic capacitors are sensitive to polarity, if connected in reverse, they may explode (on the capacitor the negative pole is noted with a strip or arrow or similar). Measure and calculate absolute and relative ripple! 2.3.5 Repeat the previous measurements with C=10µF capacitor! Compare the results with the previous exercise!

2.4 Measurement of Graetz type full-wave rectifier circuit The input and output of the Graetz circuit are not directly connected, therefore we can not measure both input and output voltages at the same time using traditional oscilloscopes, because the shielding (the outer part of the connector) of both scope channels is grounded. Therefore we are only measuring the output voltage. The input voltage is the same as in the previous measurement, anyway. The load resistor is 3.6kΩ. Figure 2.5 Graetz-type full-wave rectifier Figure 2.6 Left: Integrated Graetz bridge; Right: Electrolytical Capacitors 2.4.1 Build the circuit of figure 2.5. Connect V out to the scope. For ease of construction, an integrated Graetz package (containing the four diodes) is available, which has four pins, corresponding to the four nodes of the circuit (the rhombus in the figure). The positive output is noted with a + sign on the top of the package, next to it is the negative output, the other two indicated with a wave (~) are the AC inputs. First don't connect the C capacitor, only the R load resistor. 2.4.2 Measure the output signal on the oscilloscope (in DC coupling), note the peak value and period time. How much smaller is the peak value than the input and why? 2.4.3 Repeat the measurement after connecting a C=2.2µF capacitor. Measure the absolute and relative ripple. Compare the results with the half-wave rectifiers and explain! 2.4.4 Repeat the measurement with C=10µF capacitor.

2.5 Questions for lab entry test 1. Draw the forward characteristics of a rectifier diode! 2. Draw the reverse characteristics of a Zener diode! 3. Write down the diode equation and name the variables and constants in it! 4. Draw a half-wave rectifier circuit (with input and load connected)! 5. Draw the output waveform of a half-wave rectifier with and without a buffer capacitor, if the input in sinusoidal! 6. Draw a Graetz type rectifier, with input transformer! 7. Draw the output waveform of a Graetz rectifier with and without a buffer capacitor, if the input in sinusoidal! 8. Why is the output voltage of rectifiers smaller than the input and by how much? 9. What is the absolute and relative ripple of rectifiers? 10. How can you decrease the ripple of rectifiers?