7SD/7SH/7SM Temperature Controllers

Similar documents
- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

Analogue temperature controllers

APPENDIX APPENDIX A 1

PID CONTROLLERS LT SERIES

K3P ENG.qxd 23/10/ Pagina 1

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

170.IU0.Q , r USER MANUAL EWTQ915 EWTQ985

Fuzzy Temperature Controllers E5AF

High Performance Process & Temperature Controllers

Temperature Controllers E5 J

Instruction Manual IN February Model 7SF

MICRO-CONTROLLER X (48 48 mm)

Excellent low-cost Process & Temperature Controllers

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS

DP2000 ORDERING GUIDE To Order MODEL NO.

SPT. Description. Features. Site-Programmable, Isolated Temperature Transmitter

8003 1/8 DIN Temperature Controller

170.IU0.LFS.0B /B r USER MANUAL LFS

Temperature Controls

Fuzzy Temperature Controllers E5EF

Model Number Structure

PROCESS & TEMPERATURE CONTROLLERS

Agenda. At the end of this presentation, you will: 1. Know what is a temperature controller. 2. Why do we launch this offer?

AK48 SPECIFICATIONS APPLICATIONS GENERALS FEATURES. 1/16 DIN Process controller

1605 1/16 DIN Temperature Controller

MICRO-CONTROLLER X (96 96 mm)

I/A Series Model 718TC 1/8 DIN Temperature Controller with ma Output

SDC40A. DigitroniK TM Digital Indicating Controller RSW. Control unit PID (8) Auto tuning+ Neuro & Fuzzy RUN/READY R/L LSP.

CT325 Miniature DC Temperature Controller

Introduction To Temperature Controllers

PMW. Serial Interface INSTRUCTION MANUAL MICROPROCESSOR BASED CONTROLLER

CompoBus/D-type Digital Controller

1601 Temperature Controller

MICRO-CONTROLLER X (48 96 mm)

LAUREL ELECTRONICS, INC.

MPS SERIES. INSTALLATION and TECHNICAL MANUAL MPS 4 MPS 5 MPS 9 4 PV

DC1010/DC1020/DC1030/DC1040

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13.

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Single-phase Voltage Relay

General Specifications

General Specifications

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

General Specifications

MICRO-CONTROLLER X (48mm 48mm)

DigitroniK TM Digital Indicating Controller SDC20

General Specifications

C C1 C2 AL1 AL2 AL3. Micro-controller X. Model: PXR SEL PXR-4. Operation Manual. ECNO:406a

MODEL: KS. Plug-in Signal Conditioners K-UNIT

Table of Contents Panel Mount Controllers Analog Series C-Series Controller Software Legacy Series Power Controllers Analog Series P-Series

General Specifications

Economical Digital Indicators For Process and Electrical Measurement

DIGITAL PROGRAM CONTROLLER

Process displays For standard signals, temperature, resistance measurement

Series Valve Temperature Controller. Instruction Sheet


Page H x 96 W x 69.5 D mm (1.89 x 3.78 x 2.74 in)

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Instruction Manual (1/8 DIN) Controller With ma output.

General Specifications

General Specifications

General Specifications

250T Loop-Powered (2-wire) Transmitter 250T. Input. Isolation. 350T DC-Powered (3-wire) Transmitter 350T. Input. Isolation

1 INTRODUCTION ORDER CODE / INFORMATION

Single-phase Current Relay

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

DigitroniK Digital Indicating Controller SDC30

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Model 580 Digital Process Indicators Series

high accuracy tester-calibrator PJ 6301

DC Voltage Hawk II H235 Series Advanced Digital Panel Meter

General Purpose Digital Controllers Specifications

UL CONDITIONS OF ACCEPTABILITY

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

USB-2404-UI Specifications

EIO /2009. Zelio Control. Temperature Controller User guide 04/2009 EIO

This Errata Sheet contains corrections or changes made after the publication of this manual.

170.IU0.TMS /D r USER MANUAL TMS

Multi-point Temperature Controller

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Industrial Modbus I/O Modules

ONE CALIBRATOR ONLY MAIN FEATURES:

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

K Series. Controllers / mini-programmers with wattmeter function and independent timer

Model 332 Temperature Controller

Temperature Controller

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

Microprocessor Based Multistage Temperature Controller & Two Channel 365 Day Time Switch. Made in Australia 100% Australian Owned Company

P5201 Universal Programmable Transmitters with Galvanic Isolation

C1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

DOCUMENTATION. The new XALIS 9000 integrates a 32 bits microprocessor offering some more of performance.

C10 line User manual M.I.U.C10-1/02.06 Cod. J AC1 SEA

FC-33, DC SELECTABLE SIGNAL CONDITIONER

Transcription:

7SD/7SH/7SM Temperature ADVANTAGE EZ Series 7SD, 7SH, 7SM 1/16 DIN Temperature 3Digit LED Display Thermocouple and RTD Input Autotuning NEMA 4X Field onfigurable 100 to 40 Vac Switching Power Supply Programmable Soft Start Setpoint Ramp Password Security Standby The Advantage EZ 1/16 DIN are configurable general purpose controllers for applications where input ranges do not exceed 999. Optional Features Heat/ool ontrol (7SH) 4 Vac/Vdc Supply Relay or SSR DRIVER Relay Introduction The Barberolman Series 7 establishes a new class of microprocessor based temperature controllers. As part of the Series 7 family, the 7SD, 7SM and 7SH offer outstanding performance features in a cost effective package. Designed specifically for equipment manufacturers who demand tight process control, the 7SD, 7SM and 7SH offer a variety of standard features commonly found as options on our competitors controllers. NEMA 4X faceplates allow these units to be used in applications where washdowns and dust conditions exist. The three digit display offers complete coverage for plastics, packaging and environmental chamber applications without excess cost for unused digits. These controllers are light and compact (1/16 DIN size). They perform reliably in the most demanding applications. Even operators without skills in temperature process control or knowledge of PID control parameters can obtain perfect control. For the best results in control stability, simply: wire the instrument configure the setpoint and alarm thresholds initiate the autotune function

7SD/7SH/7SM Temperature Specifications General ase: Polycarbonate in dark grey. Selfextinguishing degree V0 according to UL94. Front Protection: Designed and tested for IP65 and NEMA 4X for indoor locations (when panel gasket is installed). Installation: Panel mounting. Rear Terminal Block: Ten screw terminals with safety rear cover. Dimensions: 48 x 48 mm (1.890 x 1.890 in.) according to DIN 43700; 100 mm (3.937 in.) depth. utout: 45 x 45 mm 0 mm, 0.6 mm. (1.77 x 1.77 in. 0 in, 0.04) Weight: 160 grams (6.6 ounces). Power Supply: From 100 to 40 Vac, 50/60 Hz, or 4 Vac/Vdc. Power Supply Variation: 15% to 10% of nominal value. Power onsumption: 5 VA. Insulation Resistance: Less than 100 MΩ (lass III apparatus) according to IE 348. Isolation Voltage: 1500 Vrms. D/A onversion: Dual slope integration. Noise Immunity: a) Electrical fast transient/burst requirements: Severity Level 3 (according to IE 8014). b) Electrical discharge requirements: Severity Level 8 (according to IE 801). Sampling Time: 500 ms typical. Accuracy: ±0.3% full scale value ±1 digit @ 5 and nominal power supply value. Temperature Drift: Less than 00 ppm/ of full scale value selected (RJ excluded). Less than 400 ppm/ of full scale value for RTD range 19.9 to 99.99. Reference Junction Drift: 0.1 /. ommon Mode Rejection Ratio: 10 db @ 50/60 Hz. Normal Mode Rejection Ratio: 60 db @ 50/60 Hz. Operating Temperature: 0 to 50. Storage Temperature: 30 to 70. Humidity: From 0% to 85% RH noncondensing. ontrol Actions On/Off, PID or Smart Autotuning Special Function: Standby alarm sequence. Protection: Internal jumper for calibration and configuration parameter protection. Inputs (All inputs are factory calibrated and selectable by front keyboard.) Input: Thermocouples (J, L, K, N) or RTD Pt 100. Input types are keyboard programmable. Engineering Units: or F configurable. Reference Junction: Automatic compensation from 0 to 50. Line Impedance: 100 Ω max for T input. Less than 4 Ω per wire for RTD input. Sensor Break: Downscale or upscale programmable. On RTD input, a special test is provided to signal OVERRANGE when input resistance is less than 15 Ω. (Short circuit sensor detection.) alibration: According to IE 5841 and DIN 437101977.

7SD/7SH/7SM Temperature Specifications (continued) Input Ranges T L 0 to 800 0 to 900 F DIN 437101977 T J 0 to 800 0 to 999 F IE 5841 T K 0 to 999 0 to 999 F IE 5841 T N 0 to 999 0 to 999 F IE 5841 RTD Pt 100 19.9 to 99. 9 DIN 43760 RTD Pt 100 199 to 500 199 to 999 F DIN 43760 s Main : ooling (7SH only) a) Relay SPDT, contact rating 3 Amps @ 50 Vac on resistive load. b) Logic output for SSR, 700 Ω maximum load, short circuit protected. Logic Level 1: 14 Vdc ±0% @ 0 ma max 4 Vdc max ±0% @ 1 ma Logic Level 0: Less than 0.5 Vdc a) Relay SPST and contact normally open, contact rating 1 Amp @ 50 Vac on resistive load. b) Logic output for SSR, 700 Ω maximum load, short circuit protected. Logic Level 1: 14 Vdc ±0% @ 0 ma max 4 Vdc max ±0% @ 1 ma Logic Level 0: Less than 0.5 Vdc Functions: Type of : Hysteresis: : Process Deviation Band Instrument Malfunctioning Annunciator High/Low (Outside/Inside for band alarm) Direct/Reverse Standby Sequence/No Standby Sequence 0.1 to 10.0% of input span or 1 least significant digit. Relay SPST 1 Amp @ 50 Vac resistive load. 7SD haracteristics Display: Bargraph: Indicators: 3 digit 7 segment LED display; 10 mm high. 1 green LED red LEDs for 5 level deviation indication. 1 red LED when heating output is ON. 1 red LED when 1 is ON. 1 green LED when Smart is enabled.

7SD/7SH/7SM Temperature Specifications (continued) 7SM and 7SH haracteristics Upper Display: Lower Display: Indicators: ooling (7SH only): 3 digit 7 segment LED display; 10 mm high. 3 digit 7 segment LED display; 7.6 mm high. 1 red LED when heating output is ON. 1 red LED when cooling output is ON or alarm is ON. 1 green LED when Smart is enabled. a) Relay SPST and contact normal open, contact rating 1 Amp @ 50 Vac on resistive load. b) Logic output for SSR 700 Ω maximum load, short circuit protected. Logic Level 1: 14 Vdc ±0% @ 0 ma max 4 Vdc max ±0% @ 1 ma Logic Level 0: Less than 0.5 Vdc Operator Interface 7SD Front Panel Description FUN Keyboard Description Enables the selftuning function (Smart ) or, during configuration/calibration procedure, scrolls back through parameters without saving them. Decreases the selected parameter. Increases the parameter or toggles between measured value and setpoint indication. Stores the parameter into memory and scrolls to the next parameter display. Barberolman F ALM SV LOW HIGH OUT FUN 7SD Display Shows the measured value. During configuration, the display toggles between the selected parameter and configured value. Indicators ALM Lit when alarm condition is present. OUT Lit during the ON period of the heating cycle. Lit when Smart function is active. SV Flashing when the display shows the setpoint. Bargraph Shows the deviation between process and setpoint. Five levels of deviation can be shown. 7SM and 7SH Front Panel Description FUN Keyboard Description Enables the selftuning function (Smart ) or, during configuration/calibration procedure, scrolls back through parameters without saving them. Decreases the selected parameter. Increases the parameter or toggles between measured value and setpoint indication. Stores the parameter into memory and scrolls to the next parameter display. ALM OOL OUT Barberolman FUN F 7SH Upper Display Shows the measured value. During configuration procedure, it shows the configured setting of the selected parameter. Lower Display Shows the setpoint. During configuration procedure, it shows the parameter code. Indicators ALM Lit during the ON period of the cooling cycle (7SH only). Lit when alarm condition is present. OUT Lit during the ON period of the heating cycle. Lit when Smart is active.

7SD/7SH/7SM Temperature Operator Interface (continued) Soft Start A configurable threshold can be used to limit output power during initial startup. Used when the impedance of heating loads change with process temperature increases. Dead Band SV Soft Start Threshold 100% 50% Heating ooling (Gain = 1.0) ooling (Gain = 0.5) ooling Gain (7SH only) Relative cooling gain can be set from 1.0 to 0. (1x to 5x the heating proportional band). onfigurable overlap/deadband allows customization of the 7SH to your unique process requirements. 0% Proportional Band Standby Standby is configurable ON/OFF to allow masking of alarm conditions when process low alarms are employed and the process value has not yet reached the alarm threshold. SV Threshold Disabled

Wiring 7SD/7SH/7SM Temperature Rear Terminal Block Power Line Wiring 10 5 9 PWR LINE 100/40 Vac or 4 Vac/Vdc OUT NO 4 8 3 7 6 MAIN SSR NO N T MAIN RELAY RTD 1 9 10 Power Supply 100 to 40 Vac RMS 4 Vac/dc To avoid electric shock, connect power line at the end of the wiring procedure. Input Wiring 1 RTD RTD 3 Shield 1 1 3 1 3 3 Thermocouple Input Wiring Shield Do not run RTD wires together with power cables. If shielded cable is used, it should be grounded at one point only. Use copper wires of appropriate size (see "Product Specifications"). The resistance of the 3 wires must be the same. Do not run input wires together with power cables. For T wiring use proper compensating cable, preferably shielded. If shielded cable is used, it should be grounded at one point only. Any external components (like zener diodes, etc.) connected between sensor and input terminals may cause errors in measurement due to excessive or unbalanced line resistance, or possible leakage currents.

7SD/7SH/7SM Temperature Wiring (continued) Wiring Relay s 6 N The MAIN OUTPUT and OUT relays are internally protected with a varistor. The contact rating for the main output is 3 Amps/50 Vac on a resistive load. The contact rating for OUT is 1 Amp/50 Vac on a resistive load. Inductive Loads High voltage transients may occur when switching inductive loads. These transients may introduce disturbances which can affect the performance of the instrument. The internal varistor assures protection up to 0.5 Amp of inductive component of the load. The same problem may occur when a switch is used in series with the internal contacts. In this case, it is recommended to install an additional R network across the external contacts as shown. Main (heating) OUT (AL1/cooling) R 7 NO 8 NO 4 5 Relay Wiring R LOAD Power Line The value of capacitor () and resistor (R) are shown in the following table. Load urrent < 150 ma < 0.5 Amp < 1 Amp (uf) 0.1 0.33 0.47 R (Ω) 47 47 Resistance Power(W) Resist. and apac. Voltage 60 60 60 Relay output wiring must be as far away as possible from input or communication cables. External Switch in Series with the Internal ontact Voltage s for SSR Drive Logic voltage for SSR drive (time proportioning). Main 7 8 Solid State Relay Logic status 1: Logic status 0: 4V 0% @ 1 ma 14 V 0% @ 0 ma Less than 0.5 V This output is not isolated. Isolation between instrument output and power supply must be assured by the external solid state relay. SSR Drive Wiring See ontroller Mounting Dimensions at the end of this section.