Image. Installation VAV-Universal Retrofit-Set. General Information. Safety notes

Similar documents
Installation of VAV-Compact Retrofit with ZDMS-..

..-MF /..-MP /..-MFT(2) /..-MOD /..LON..-MF /..-MP /..-MFT(2) /..-MOD /..LON

Brief description. Type overview

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

VAV solutions for comfort applications

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Technical data. Parameterisable damper actuator in the

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Adaptive control system for duct and room pressure applications. Table of Contents

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Brief description. VAV-Compact MP en-gb Changes reserved 1. Application. Pressure measurement. Actuator

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data sheet. Technical data. Safety notes

Power consumption Operation At rest Wire sizing

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Technical data. Safety notes

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Functional data Factory settings Variable Settings

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Type overview. Technical data

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

Introduction to MP-Bus Technology

VLV55 VLV65 Volumetric flow controller

Extension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Overview of types. Technical data

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Volumetric flow controller

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Volumetric flow controller

Rp [ ] [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

VAV solution for controlled apartment ventilations

Product information. Technical data. Safety notes. Definitions

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Volumetric flow controller

DN [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

VAV Rectangular Terminal Units

ELECTRONIC THERMOSTAT: T920

CR24-.. Single room controllers

VAV-Compact. Contents. Modbus General Notes 2 Modbus Register Overview 3 Modbus Register Description 4

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Brief description. VAV-Compact LON en-gb Changes reserved 1. Application. Pressure measurement

Intelligent Compact Controller

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

ELECTRONIC THERMOSTAT: T951

Installation Manual. Ultra RF Analogue Transmitter QC0168. Manual Ref: QC0168. Version: March

Universal Controller

Actuating Terminal Equipment Controller (ATEC) Base VAV - Cooling or Heating, Application Application Note

Specification GRUNER YSP 227C

Electro Controls. Input-Output Modules WattsIndustries.co.uk

Differential pressure sensors

Magnetic Inductive Flow Sensor induq

Operating Manual Axis 60mm Self Centering Vise Axis 100mm Self Centering Vise

Limit switch set BOA-H DN PN 16/25 Material variant EN-GJS LT

Audi Q7 Running board Fitting Instructions

REACTa. Installation Commissioning Maintenance Installation circular version Legend to figures 3-5: Min. 500 mm. Min.

Valve amplifier for proportional pressure valves

Micro Channel. Shorten the Fixture (optional) Installation Instructions for 700UMCD_ UNILUME. This product is suitable for damp locations.

XXXX e. X d.. X X X a

Belimo Gateway MP to BACnet MS/TP - UK24BAC

ASV115CF132: Standard VAV compact controller

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Room Temperature Controllers. for heating and cooling systems

EY-EM 527: Remote I/O module, ecolink527

Please be sure to read this manual before using the product.

FEATURES OPTIONAL FEATURES

BA507C & BA508C loop-powered 3½ digit panel mounting indicators

Installation Manual. 3 Phase Wireless Meter QC0142. Version: NOV16 1.0

Room Temperature Controllers. for heating and cooling systems

5-Axis Machine Tools from SMW-AUTOBLOK

XXXX e. X d.. X X X a

Room Temperature Controllers. for heating and cooling systems

Self contained servo drive CLDP Technical data sheet

DC Current Transducers

NEXUS NX50-1, -2 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION

Transcription:

VAV-Universal Retrofit-Set VRD-RE-SET VAV-Universal Retrofit Set for utilisation of existing VAV devices made by various manufacturers. VRD-RE-SET for air velocity up to m/s. Image Suitable only for round VAV boxes. General Information Application The VAV-Universal Retrofit Set makes possible an efficient replacement of VAV and CAV devices made by various manufacturers. Each package contains all of the component parts required for making the conversion. Package contents 5 VAV controller VRD-RE Damper actuator NMA-V-RE Pick-up device ZPD-RE Anti-rotation strap 5 Form-fit insert 8 x 8 mm installation instructions These installation instructions describe the application of the VAV-Universal Retrofit Set VRD-RE-SET. For a detailed description, we draw your attention to the separate product documentation of the VRD and NMA-V, see www.belimo.eu Documentation Room and System Solutions. Belimo Automation AG can at any time implement changes and improvements without prior notification. For the current edition of the operating instructions, see www.belimo.eu Safety notes! The device is not allowed to be used outside the specified field of application, especially not in aircraft or in any other airborne means of transport. It may only be installed by suitably trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. The device may only be opened at the manufacturer's site. It does not contain any parts that can be replaced or repaired by the user. The cable must not be removed from the device. When calculating the required torque, the specifications supplied by the damper manufacturers (cross-section, design, installation site), and the air flow conditions must be observed. The device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. www.belimo.eu M-VAV-Universal Retrofit Set en v.0 05.009 Subject to changes / 9

Dismantling the existing VAV controller Electrical connection Mechanical components. In the control cabinet, undo supply/signal cable to the outgoing terminals Caution: Observe and note connection sequence. Undo supply/signal cable to the VAV controller Caution: Observe and note connection sequence. Dismantling the existing pick-up device. Dismantling the controller. Dismantling the actuator of the new pick-up device Measured value recording The installation position and the inflow of the pick-up device are of decisive importance for measuring accuracy. If the measurement recording is positioned in an area of turbulence or if no sufficiently wide-ranging flow takes place, then measurement inaccuracies could occur under certain circumstances. Placement A B A B Measurement site Maximum hose length m per measurement line position D = 00 50 D = 80 00 Air duct Bore hole for mounting pick-up device Clearance between the pick-up devices Air direction D B [mm] 80 0 5 7 55 79 00 D = 00 50 D = 80 00 Two pick-up devices are required for VAV boxes from 80 to 00 mm. For this purpose use the ZPD-RE-SET. / 9 M-VAV-Universal Retrofit Set en v.0 05.009 Subject to changes www.belimo.eu

of the new pick-up device (continued) Preparation. Shorten the pick-up device to the diameter of the VAV unit. The auxiliary template is located on the packaging of the set. The specified lengths must be maintained without fail in order to ensure that the desired measuring accuracy can be achieved.. Mount pick-up device seal. Bore an opening in the duct; hole size: 6 mm. of the pick-up device in the duct Caution: Observe direction of arrow for air +. Mount pick-up device with accompanying screws www.belimo.eu M-VAV-Universal Retrofit Set en v.0 05.009 Subject to changes / 9

of the new damper actuator Spindle clamp installation The damper actuator for VAV boxes NMA-V-RE is equipped with the base plate for form-fit mounting. The front mounting clip may not be used under any circumstances when the actuator is used with clamp connection (Illustration ). Damage to the VAV unit and/or the damper actuator would be the result. 0 8... 6.7 8 6.7 0 0 mm 9 Nm Spindle clamp installation with short axes 0 / 9 M-VAV-Universal Retrofit Set en v.0 05.009 Subject to changes www.belimo.eu

of the new damper actuator (continued) with form-fit 8 x 8 mm 5 mm Adjusting angle of rotation limiter Incorrect settings can lead to damage to the damper blade and to a diminishment of the quality of the control. The two mechanical end stops for angle of rotation limiting must be tailored to the conditions of the VAV unit and are therefore to be adjusted very carefully. The dismantled actuator is used as an orientation aid for placing the end stops. of the new VAV controller Dimensional drawings 5 0 0.5 88 5 5 5 Mounting and connecting. Mount the VRD-R VAV controller at a suitable position near the damper actuator NMA-V-RE.. Plug the NMA-V-RE actuator with the plug-ready connecting cable into the controller. www.belimo.eu M-VAV-Universal Retrofit Set en v.0 05.009 Subject to changes 5 / 9

T VAV-Universal Retrofit-Set of the new VAV controller (continued) Attaching hoses to the controller and pick-up device. Mount the two accompanying angle pieces to the connection nipples of the pick-up device.. Attach hoses to VAV controller with pick-up device Caution: Observe connection (±) Depending on the type of installation of the VAV controller and of the damper actuator, individual parts such as screws, positive fit inserts or universal mounting brackets are not required and remain left over after completion of the installation. Operation, setup, connection Setup, connections 8 min % nom max % nom 5 6 7 + ~ w VA C/DC 50/60Hz.5W VA IP III PP U5 Z Z 7 Power Actuator 6 5 a b Service VRD VRD Operating volumetric flow setting min 0 00% [in % of nom ] Operating volumetric flow setting max 0 00% [in % of nom ] connection a System plug: internal Belimo function, not for users b Service: connection for VAV adjustment tool ZTH-VAV Jumper for input w (terminal ) Function: VRD: VRD-compatible VRD: VRD and L/N/SMV-D-MP 5 Power LED, Function display V 6 Connection for V-actuator 7 Connecting terminals 7 8 Connection D Sensor / 9 M-VAV-Universal Retrofit Set en v.0 05.009 Subject to changes www.belimo.eu

Operation, setup, connection (continued) Connecting terminals 7 Terminal Designation Function / ~ / + Supply VAC/DC s Supply via safety isolation transformer!! It is recommended that the PP connection (terminal ) and the V be wired to readily accessible terminals in order to guarantee easy access with the VAV adjustment tool ZTH-VAV (e.t. at the room temperature controller CR or in the control cabinet). The VRD does not support any MP operation! w Reference value input w jumper VRD Mode 0 0/ 0V switchable with ZTH-VAV Function as with new VAV-Compact L/N/SMV-D-MP: VAV: 0 0/ 0V = min max CAV: CLOSED/ min / max /OPEN Reference value input w jumper VRD Mode 0 0/ 0V switchable with ZTH-VAV Function as with VRD: VAV: 0 0/ 0V = min max CAV: not possible use Z / Z PP PP interface for ZTH-VAV (no MP operation) 5 U5 Actual volumetric flow signal U5 Mode 0 0/ 0V switchable with ZTH-VAV Display range 0 00% nom 6 Z Override input Z: Function OPEN 7 Z Forced control input Z: function CLOSED/ min / max For a detailed description of the VAV controller VRD, we draw your attention to the separate product information, see www.belimo.eu Documentation Room and System Solutions. Setting and first commissioning Adjusting the volumetric flow The adaptation of the VAV-Universal Retrofit Set to the nominal width of the VAV/CAV unit is accomplished by shortening the pick-up device in accordance with the auxiliary template (see page ). No further calibration of the controller to the system is required. The adaptation of the volumetric flow to the system is accomplished with the setting of the two operating volumetric flow parameters min and max. The settings for min and max can be readily calculated with the aid of the table below and the associated formulas. 0 V 0 / V U5 0 V V min Table, formulas max W 0 V 0 V nom Diameter VAV- Box VRD-RE nom [l/s] nom [m /h] 00 97 9 5 50 5 5 55 0 95 70 60 50 900 80 5 00 0 5 55 890 50 67 80 795 86 5 08 70 55 75 590 00 676 60 Formulas max in % = max [l/s, m /h] x 00 nom [l/s, m /h] min in % = min [l/s, m /h] x 00 nom [l/s, m /h] Example Data Calculation/result VAV unit diameter 80 mm nom from Table m /h max 000 m /h min 0 m /h 000 m max = /h x 00 = 88 % m /h 0 m min = /h x 00 = 0 % m /h www.belimo.eu M-VAV-Universal Retrofit Set en v.0 05.009 Subject to changes / 9

Setting and first commissioning (continued) min / max setting [Potentiometer or (PP command)] Die operating volumetric flow settings min and max can be adjusted two different ways on the VRD-RE: a) directly on the adjustment potentiometer (analogous to the VRD) min 0 00% of nom max 0 00% of nom b) with VAV adjustment tool ZTH-VAV (PP command) To write a value with PP command - into the VRD-RE both of the potentiometers min and max must be at the position. If the potentiometer(s) is/are set to with ZTH-VAV connected, then the menu may under certain circumstances need to be refreshed through actuation of the keys. For function, see following illustration: concerning difference min setting VRD, VRD The adjustment range of the operating mode min with: VRD refers to 0 00% of max VRD refers to 0 00% of nom The min setting of the VRD thus behaves in compatible fashion with the new VAV generation (starting with 006), i.e. VAV-Compact L/N/SMV- D-MP, VRP-M. Adjustment potentiometer min / max VRD 0 0 50 60 0 70 0 0 80 90 ZTH-VAV + OK 00 ZTH-VAV parameterised value 5 % 0 00% (PP) Automatic adjustment via potentiometer position Potentiometer: : ZTH value 0 00%: Potentiometer value active r = read w = write effective value 5 % The max value must always be set higher than the min value; otherwise the VRD-RE controller will operate with the min volume as setpoint in CAV mode. w r VRD-RE setting with VAV adjustment tool ZTH-VAV The entire BELIMO product range with PP connection can be set and controlled with the VAV adjustment tool ZTH-VAV. The connection to the VRD-RE is provided by the RJ «Service» socket or at the PP connection (terminal ), e.g. in the control cabinet. Operating menu VRD-RE Option Unit Range/setting Function Volumetric flow actual value % 0 00% [of nom ] Commissioning, Service function Volumetric flow - setpoint % 0 00% [ min max ] Current pressure value Pa 0 00 Pa Specify CAV steps Auto CLOSED OPEN min max Stop Mode 0 0V, 0V min setting % 0 00% [of nom ] Settings, max setting % 0 00% [of nom ] modifications nom VAV box % Nominal setting = 00% p @ nom Pa differential pressure pending with nom * Function is displayed, starting with ZTH-VAV Firmware V.0 or higher (starting 06.008). See also Release ZTH-VAV, www.belimo.eu OEM setting 8 / 9 M-VAV-Universal Retrofit Set en v.0 05.009 Subject to changes www.belimo.eu

VRD-RE setting with VAV adjustment tool ZTH-VAV (continued) Connection Connection to Cable type and order designation VRD-RE, RJ «Service» socket ZK6-GEN Accessories PP connection (terminal ), e.g. control cabinet terminals ZK-GEN Accessories white blue turquoise GND ~ / + PP ZTH-VAV + OK min % nom max % nom ZK6-GEN Power Service VRD VRD Actuator turquoise blue white ZK-GEN For detailed documentation concerning the handling and function of the ZTH-VAV, see ZTH-VAV instruction manual at www.belimo.eu Carry out adaption An angle of rotation adaption of the damper actuator is recommended at the time of initial commissioning. An angle of rotation adaption must however be carried out after the adjustment of the angle of rotation limitations. Procedure: Switch on the V supply on the VRD-RE Press the «Adaption» pressure switch on the damper actuator (actuator travels CLOSED OPEN setpoint position) Performance check Additional optimisation options can be achieved together with the single room controllers CR. Information concerning these options can be found on the Belimo web site www.belimo.com A performance check is recommended after the installation of the VAV controller and the completion of the adaption. Set the VAV controller with the ZTH-VAV to maximum and then afterwards to minimum air volume («max»/«min»). Check whether the required amounts of air have been attained. www.belimo.eu M-VAV-Universal Retrofit Set en v.0 05.009 Subject to changes 9 / 9