PM734B - Technical Data Sheet. Generator Solutions AS

Similar documents
PI734C - Technical Data Sheet

PI734A - Technical Data Sheet

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

WDG 12 - Technical Data Sheet

WDG 61 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 51 - Technical Data Sheet

WDG 71 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 83 - Technical Data Sheet

WDG 13 - Technical Data Sheet

WDG 07 - Technical Data Sheet

S4L1D-G41 Wdg Technical Data Sheet

S4L1S-D4 Wdg.17 - Technical Data Sheet

S0L1-J1 - Technical Data Sheet

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCM634G - Technical Data Sheet

440 (12) 416 (12) 416 (12) 440 (12)

PARTNER ALTERNATORS LSA 40-4 Pole

Low Voltage alternators - 4 pole LSA 47.2

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

LSA Pole. R 726 Mains paralleling

Low Voltage alternators - 4 pole LSA 46.2

TAL 047 Low Voltage Alternator - 4 pole

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

PARTNER ALTERNATORS LSA Pole

TAL 049 Low Voltage Alternator - 4 pole

TAL 044 Low Voltage Alternator - 4 pole

Packaged Generators: New Kato Engineering Packaged Generator Line: Over 75 Years of Experience: Conformity: Service: Quality Standards:

Spec Information. Reactances Per Unit Ohms

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

GENERATOR DATA JANUARY 30, 2015

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

Spec Information. Reactances Per Unit Ohms

AGN 034 Alternator Reactance

Generator Advanced Concepts

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

AGN 005 Fault Currents and Short Circuit Decrement Curves

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

Application Guidance Notes: Technical Information from Cummins Generator Technologies

Sizing Generators for Leading Power Factor

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

SPECIFICATION, CONTROLS AND ACCESSORIES

SYNCHRONOUS MACHINES

AGN 124 AVR Power Supplies

SPECIFICATION, CONTROLS AND ACCESSORIES

STEADY STATE REACTANCE

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

PART 1 OWNER/APPLICANT INFORMATION

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

AGN 124 AVR Power Supplies

APPENDIX B: Generation Interconnection Application Form

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

Code No: R Set No. 1

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

Contents. About the Authors. Abbreviations and Symbols

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW

Alternators Reactance for Nonlinear Loads

SPECIFICATION, CONTROLS AND ACCESSORIES

Conventional Paper-II-2011 Part-1A

Orbital GFI Inverter Series

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

Generation Interconnection Study Data Sheet Synchronous Machines

AGN 022 Conditions for Parallel Operation

APPLICATION FOR INTERCONNECTION & OPERATIONS OF MEMBER-OWNED GENERATION

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

PAPER-II (Subjective)

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

Low Voltage Alternators

The new Yaskawa Varispeed G7 Inverter

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

Impact Assessment Generator Form

Power Factor. Power Factor Correction.

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

Using the VR448 in place of the Marathon DVR 2000

Type of loads Active load torque: - Passive load torque :-

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

Conventional Paper-II-2013

TABLE OF CONTENT

D I G I T A L V O L T A G E R E G U L A T O R

DATAMAX GENERATORS DATA C E NT E R A P P L I C AT I O N S, TO K W LOW A N D H I G H VO LTAG E, 6 0 A N D 5 0 H Z

TETRA COMPACT LOW VOLTAGE BRUSHLESS SERVOMOTORS

AGN 026 Harmonic Voltage Distortion

Transcription:

- Technical Data Sheet

STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and certifications can be considered on request. DESCRIPTION The STAMFORD PM range of synchronous ac generators are brushless with a rotating field. They are separately excited by the STAMFORD Permanent Magnet Generator (PMG). This is a shaft mounted, high frequency, pilot exciter which provides a constant supply of clean power via the Automatic Voltage Regulator (AVR) to the main exciter. The main exciter output is fed to the main rotor, through a full wave bridge rectifier, protected by surge suppression. VOLTAGE REGULATORS The PM range generators, complete with PMG, are available with one of two AVRs. Each AVR has soft start voltage build up and built in protection against sustained over-excitation, which will de-excite the generator after a minimum of 8 seconds. Underspeed protection (UFRO) is also provided on both AVRs. The UFRO will reduce the generator output voltage proportional to the speed of the generator below a presettable level. The MX341 AVR is two phase sensed with a voltage regulation of ± 1 %. (see the note on regulation). The MX321 AVR is 3 phase rms sensed with a voltage regulation of 0.5% rms (see the note on regulation). The UFRO circuit has adjustable slope and dwell for controlled recovery from step loads. An over voltage protection circuit will shutdown the output device of the AVR, it can also trip an optional excitation circuit breaker if required. As an option, short circuit current limiting is available with the addition of current transformers. Newage may use a third AVR, the MA330, under certain circumstances. The MA330 AVR has 3 phase rms sensing, it has similar performance to the MX321. It is a Pulse Width Modulated AVR with a higher output power under short circuit conditions. All of the above AVRs require a generator mounted current transformer to provide quadrature droop characteristics for load sharing during parallel operation. Provision is also made for the connection of the STAMFORD power factor controller, for embedded applications, and a remote voltage trimmer. SPECIFICATIONS & OPTIONS WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low levels of voltage waveform distortion. TERMINALS & TERMINAL BOX Standard generators feature a main stator with 6 ends brought out to the terminals, which are mounted on the frame at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H', and meets the requirements of UL1446. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. NOTE ON REGULATION The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. Note: Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing is typical of the product range. 2

CONTROL SYSTEM WINDING 312 SEPARATELY EXCITED BY P.M.G. A.V.R. MX341 MX321 MA330 VOLTAGE REGULATION ± 1% ± 0.5 % ± 0.5 % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT INSULATION SYSTEM PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS MAIN STATOR RESISTANCE MAIN ROTOR RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR WR² INERTIA SHIPPING WEIGHTS in a crate PACKING CRATE SIZE TELEPHONE INTERFERENCE COOLING AIR 2250 Rev/Min BALL. 6228 C3 BALL. 6319 C3 1 BEARING 2 BEARING VOLTAGE STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277 kva BASE RATING FOR REACTANCE VALUES REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) 2760 kg 1306 kg 1139 kg 32.7498 kgm 2 194 x 105 x 154(cm) 50 THF<2% CLASS H 2710 kg 1306 kg 1077 kg 31.7489 kgm 2 2833kg 2779kg 194 x 105 x 154(cm) 2.69 m³/sec 5700 cfm 3.45 m³/sec 7300 cfm 1130 1190 1230 1240 1260 1335 1395 1455 Xd DIR. AXIS SYNCHRONOUS 2.91 2.77 2.66 2.38 3.51 3.32 3.18 3.04 X'd DIR. AXIS TRANSIENT 0.18 0.17 0.16 0.14 0.21 0.20 0.19 0.19 X''d DIR. AXIS SUBTRANSIENT 0.13 0.13 0.12 0.11 0.16 0.15 0.14 0.14 Xq QUAD. AXIS REACTANCE 1.88 1.78 1.71 1.54 2.26 2.14 2.05 1.96 X''q QUAD. AXIS SUBTRANSIENT 0.26 0.25 0.24 0.22 0.32 0.30 0.29 0.28 XL LEAKAGE REACTANCE 0.03 0.03 0.03 0.03 0.04 0.04 0.04 0.03 X2 NEGATIVE SEQUENCE 0.19 0.18 0.17 0.15 0.22 0.21 0.20 0.19 X0 ZERO SEQUENCE 0.02 0.02 0.02 0.02 0.03 0.03 0.02 0.02 REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED T'd TRANSIENT TIME CONST. 0.13s T''d SUB-TRANSTIME CONST. 0.01s T'do O.C. FIELD TIME CONST. 2.14s Ta ARMATURE TIME CONST. 0.02s SHORT CIRCUIT RATIO 1/Xd IP23 0.8 DOUBLE LAYER LAP TWO THIRDS 0.0016 Ohms PER PHASE AT 22 C STAR CONNECTED 1.67 Ohms at 22 C 17.5 Ohms at 22 C 0.048 Ohms PER PHASE AT 22 C 3 6 60 TIF<50

50 Winding 312 THREE PHASE EFFICIENCY CURVES 4

Winding 312 THREE PHASE EFFICIENCY CURVES 60 5

PER CENT TRANSIENT VOLTAGE DIP. PER CENT TRANSIENT VOLTAGE DIP. 30 25 20 15 10 5 30 25 20 15 10 5 50 Winding 312 Locked Rotor Motor Starting Curve 0 0 500 1000 1500 2000 2500 3000 3500 60 346V 380V 400V 415V 440V LOCKED ROTOR kva 380V 416V 440V 460V 480V 0 0 500 1000 1500 2000 2500 3000 3500 LOCKED ROTOR kva 6

50 60 MX341 or MX321 Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed Based on star (wye) connection. CURRENT (Amps) 100000 10000 1000 0.001 0.01 0.1 1 10 Sustained Short Circuit = 4,400 Amps CURRENT (Amps) 100000 10000 Sustained Short Circuit = 4,650 Amps Note 1 Note 2 The following multiplication factors should be The following multiplication factor should be used to convert the used to adjust the values from curve between values calculated in accordance with NOTE 1 to those applicable time 0.001 seconds and the minimum current to the various types of short circuit : point in respect of nominal operating voltage : 50 60 3-phase 2-phase L-L 1-phase L-N Voltage Factor Voltage Factor Instantaneous x 1.00 x 0.87 x 1.30 380v x 1.00 416v x 1.00 Minimum x 1.00 x 1.80 x 3.20 400v x 1.05 440v x 1.06 Sustained x 1.00 x 1.50 x 2.50 415v x 1.09 460v x 1.10 Max. sustained duration 10 sec. 5 sec. 2 sec. 440v x 1.16 480v x 1.15 All other times are unchanged The sustained current value is constant irrespective Note 3 of voltage level Curves are drawn for Star (Wye) connected machines. TIME (secs) SYMMETRICAL ASYMMETRICAL 1000 0.001 0.01 0.1 1 10 TIME (secs) SYMMETRICAL ASYMMETRICAL 7

50 60 MA330 Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed Based on star (wye) connection. CURRENT (Amps) 100000 10000 1000 0.001 0.01 0.1 1 10 Sustained Short Circuit = 5,150 Amps CURRENT (Amps) 100000 10000 Sustained Short Circuit = 5,250 Amps Note 1 Note 2 The following multiplication factors should be The following multiplication factor should be used to convert the used to adjust the values from curve between values calculated in accordance with NOTE 1 to those applicable time 0.001 seconds and the minimum current to the various types of short circuit : point in respect of nominal operating voltage : 50 60 3-phase 2-phase L-L 1-phase L-N Voltage Factor Voltage Factor Instantaneous x 1.00 x 0.87 x 1.30 380v x 1.00 416v x 1.00 Minimum x 1.00 x 1.80 x 3.20 400v x 1.05 440v x 1.06 Sustained x 1.00 x 1.50 x 2.50 415v x 1.09 460v x 1.10 Max. sustained duration 10 sec. 5 sec. 2 sec. 440v x 1.16 480v x 1.15 All other times are unchanged The sustained current value is constant irrespective Note 3 of voltage level Curves are drawn for Star (Wye) connected machines. TIME (secs) SYMMETRICAL ASYMMETRICAL 1000 0.001 0.01 0.1 1 10 TIME (secs) SYMMETRICAL ASYMMETRICAL 8

50 60 Class - Temp Rise Star (V) kva kw Efficiency (%) kw Input Star (V) kva kw Efficiency (%) kw Input Winding 312 / 0.8 Power Factor RATINGS Cont. B - 70/50 C Cont. F - 90/50 C Cont. H - 110/50 C 380 400 415 440 380 400 415 440 380 400 415 440 955 1005 1010 990 955 1005 1040 1105 1130 1190 1230 1240 764 804 808 792 764 804 832 884 904 952 984 992 95.8 95.8 95.9 95.9 95.8 95.8 95.9 95.9 95.6 95.7 95.7 95.7 797 839 843 826 797 839 868 922 946 995 1028 1037 416 440 460 480 416 440 460 480 416 440 460 480 1095 1170 1190 1215 1110 1170 1220 1280 1260 1335 1395 1455 876 936 952 972 888 936 976 1024 1008 1068 1116 1164 95.7 95.7 95.8 95.8 95.6 95.7 95.8 95.8 95.6 95.7 95.7 95.7 915 978 994 1015 929 978 1019 1069 1054 1116 1166 1216 DIMENSIONS 2004 Newage International Limited. Reprinted with permission of N.I. only. Printed in England. Barnack Road Stamford Lincolnshire PE9 2NB Tel: 00 44 (0)1780 484000 Fax: 00 44 (0)1780 484100 Website: www.newage-avkseg.com TD_.GB_05.04_01_GB