Granite Ridge Shingle Guardian Shingle

Similar documents
Gerard Installation Manual Shingle Profiles

Guardian Shingle Granite Ridge Shingle

Installation Manual. For Gerard Shingle Products

Installation Manual. Future Shingle Products

Installation Manual. Future Roof Shingle / Slate Products

Table of Contents. Important Notices 3. Residential Roofing Application 4. Trims & Accessories 5. Trim & Accessory Glossary 6, 7, 8

BARRELL VAULT BATTENLESS

Barrel Vault Counter Batten and Batten

MetroCOTTAGE Shingle

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

installation guide Villa

SLATE & SHINGLE INSTALLATION

INSTALLATION DETAILS

Table of Contents. Roof to Head Wall w/ Side Flashing DECRA Shake XD Roof Overview Roof Penetration - Pipes & Vents...

Table of Contents. Fasteners... 4 Venting Preparation Installation with Battens - DECRA Tile & DECRA Shake 1

INSTALLATION GUIDE LEARN MORE AT DECRA.COM

Ekoroof LiteTile Dimensions

DECRA Shingle Installation Guidelines

Table of Contents. Important Notices 3. Residential Roofing Application 4. Trims & Accessories 5. Trim Glossary 6, 7, 8. Estimating Material 9

Inspire Aledora Slate Application Guidelines

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

INSTALLATION GIUDE.

IRONWOOD SHAKE & FLASHING SPECIFICATIONS

METRO PANELS (EXPOSED

IRONSTONE SLATE & FLASHING SPECIFICATIONS IRONSTONE SLATE

Table of Contents. Installation Guide for Profile with Hidden Fasteners 3. Installation Steps 4, 5. Prestige Series Moldings 6, 7. Other Accessories 8

Turada Hardwood Shingles and Shakes Installation instructions

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

eco-shake INSTALLATION INSTRUCTION

INSTALLATION WARNING! These install details are provided to demonstrate a recommended installation method for Metro Roof panels and accessories.

b) Symphony comes pre-packaged in color and width blends. There is no need to mix Symphony at the job site. Currently Symphony is available in the

Installation Instructions

Tuff-Rib Install Guide

CertainTeed. Shake / Slate Installation Guide

Metro Batten Installation Details

Steel Roofing & Siding INSTALLATION GUIDE

Terrabella Shake & Shingle Znap Ver. 2.0

SmartVent Eave Edge Installation Instructions

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes

DIRECTIONS FOR APPLICATION

REGAL. Installation Manual

Slate Shingle Specifications

A P P L I C A T I O N I N S T R U C T I O N S

DIRECTIONS FOR APPLICATION

SG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application

DIRECTIONS FOR APPLICATION

METAL ROOFING INSTALLATION GUIDE

Brava Old World Slate Installation Guide

Gerard Battenless Profiles

RIDGEMASTER PLUS CAUTION INSTALLATION INSTRUCTIONS ALWAYS WEAR SAFETY GLASSES TOOLS NEEDED GENERAL GUIDELINES FOR RIDGEMASTER PLUS AND HIPMASTER

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

Installation Instructions

ROOFING APPLICATION STANDARD (RAS) No. 130

TABLE OF CONTENTS A-1

TIOGA Table of Contents

3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25

Installation Guide. Cedar Shake. Distributed by: BEST MATERIALS LLC, Phoenx AZ

Roofing Training - Basics. Sandy Wesch

Installation Guide. Titan Old World Slate REV Titan Manufacturing Phone: (407) Fax: (866)

HipMaster Installation Instructions

Stone coated steel roof tile INSTALLATION GUIDE

6 STEP INSTALLATION GUIDE BY DCI


StormMaster Slate General Instructions 1.) GENERAL INSTRUCTIONS 2.) ROOF DECK VENTILATION 3.) ROOF DECK

1 Roof Substrate (Deck) OWENS CORNING BERKSHIRE SHINGLES INSTALLATION INSTRUCTIONS

BARDOLINE INSTALLATION INSTRUCTIONS

Tuff-Rib. Installation Manual. Nationwide supplier of quality metal roofing. Toll-Free (800) S. Lee Hwy. Cleveland, TN 37311

Cambridge English Application Instructions

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

Application Guidelines - Shake General Information

Best Buy Metals Toll Free / Phone / Fax

How To Install Asphalt Shingles. Part 1 of 3: Preparing the Roof. Tutorial

AIA Specification. Section Slate Shingles PART 1 GENERAL

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights

ONDUVILLA. The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S

ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION

4. Metal roof jacks at penetrations and attachments

HERITAGE LAMINATED ASPHALT SHINGLES Frederick, MD

Installation Manual SOLID CORE SIDING

ROOFING City of Grand Rapids Building Safety Division

RED DIAMOND SHINGLES Roof Installation Introduction:

COMPOSITE SIDING INSTALLATION GUIDE

PROJECT INSTRUCTIONS Roofing

INSTALLATION PROCEDURE

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

OWENS CORNING LAMINATE SHINGLES INSTALLATION INSTRUCTIONS

Steel Shingle Installation Guide

Installation Instructions for Siding

Hatteras Shingles. CertainTeed Shingle Applicator s Manual. YOUR OBJECTIVE: To learn the correct procedures for installing Hatteras shingles

DW HORIZONTAL INSTALLATION

Shingle Installation Guide

Straight Rib Series Metal Roofing Panel Installation Guide

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

Shapes Siding. Perfection Shingles. Chalk Line

Tapersawn Shake Installation Instructions

F-WAVE REVIA SYNTHETIC ROOFING SHINGLES

DETAIL MANUAL for Standing Seam / Image II

Capstone Application Instructions

Transcription:

Allmet Installation Manual Shingle Profiles Granite Ridge Shingle Guardian Shingle March 2017

This Installation Manual is designed as an instructional tool to clearly depict to the contractor, installer, distributor and architect, recommended installation techniques and procedures to confidently estimate and install a Granite Ridge and Guardian Shingle roofing system by Allmet Roofing Products. This manual depicts generally practiced application techniques only, which should not be substituted for local building code specifications. Allmet Roofing Products carries product approval reports for most building code agencies in North America which should be referenced for specific local requirements (see Allmet s website for further information). These methods have been developed by Allmet Roofing Products as proven acceptable and tested methods of installing Allmet Stone Coated Steel Roofing Products. Allmet Roofing Products does not construe that these are the only methods but again are the tried and true proven techniques that are currently practiced by the majority of trained installers. This manual emphasizes common roofing practices in use today. If application techniques vary from those illustrated in this manual or if using this manual for applications not covered, please consult the technical department at 1-800-265-9357. As Allmet Roofing Products have no control over the installation techniques used, no warranty can be made relating to the installation of Allmet products. Testing reports for various areas are available which should be analyzed for additional procedures after careful review of this manual. A careful study of this manual will give a full comprehension of a Granite Ridge and Guardian Shingle roof installation. Allmet Roofing Products assumes no liability for either incorrect installation of its products or personal injury that may occur as a result of installing such products. The installation methods demonstrated in these materials are not the only ways to install Allmet products, but have been developed as a reference guide using acceptable, tested and proven methods for the standard installation of Allmet products. Contractors and installers should at all times use their professional judgment, and modify and tailor such methods where appropriate or necessary to suit each specific installation or any applicable local building codes or ordinances. Due to the fact that Allmet has no control over the actual installation techniques used, no warranty is expressed or implied relating to installation of the product. Allmet s liability with respect to Allmet products is limited exclusively to its standard written limited lifetime warranty. Please Note: It is the responsibility of the installer to adhere to local building codes. 2

Table of Contents Allmet Shingle Description 4 Tool Requirements 5 Materials 6 8 Estimating 9 Roof Preparation 10 Rake/Roof-To-Wall and Felt 11 Valley 12 Shingle Installation 13 Roof-To-Wall, 110* Head Metal and Valley Cap Detail 14 Hip and Ridge 15 Riglet Installation 16 Pipe Jack Installation 17 Optional Masterflash 18 Touch Up and Completion 19 3

Allmet Shingle Description Granite Ridge Shingle 15 5/8 13 11/16 Guardian Shingle 15 5/8 13 11/16 Actual Exposure Coverage Average weight per shingle Average weight per square Roof Pitch 46 1/6 x 15 5/8 44 x 13 11/16 24 shingles per square 5 lbs 120 lbs 4:12 minimum 4

Tool Requirements List of Tools Required: - Standard claw hammer - 50 or 100 tape measure - Screw drivers (optional power drive) - Utility knife (when re-roofing over composition shingle) - Tin snips - Caulking gun - Chalk line - One pair of needle-nose pliers Allmet Tile Cutter Part # 10000050 - creates neater, straighter cuts Replacement Handle Grip Part No: 500-000-08 Replacement Top Blade Part No: 500-000-13 Replacement Bottom Blade Part No: 500-000-12 The Tru-Cut Shear is reversible for left-handed or right-handed use. Assembly shown here is for right-handed use. Simply reverse assembly for left-handed use. 5

Materials Granite Ridge Shingle Part No: 620-XXX-01 Stone Coated Weight: 4.9 lbs (2.22 kg.) 24 pcs. / sq. Guardian Shingle Part No: 630-XXX-01 Stone Coated Weight: 4.9 lbs (2.22 kg.) 24 pcs. / sq. Valley Cap - Part No. 620-XXX-04 Stone Coated Weight: 3.5 lbs. (1.72 kg) 120 (10 ft.) lengths Char Filter Foam (Under Valley Cap) - Part No. 620-000-33 Non-Stone Coated 3/4 x 4-1/2 x 118 Length Allmet Shingle Valley Part No. 620-000-12 Non-stone Coated Weight: 18 lbs. (8.17 kg) 120 (10 ft.) lengths Riglet Part No. 620-XXX-10 Non-stone Coated Weight: 2.36 lbs. (1.07 kg) 120 (10 ft.) lengths Rake/Roof to Wall Part No. 620-000-11 Non-stone Coated Weight: 3.15 lbs. (1.43 kg) 120 (10 ft.) lengths (To be used with Rake Cover or Z-Bar attachment) 6

Materials Z-Bar Attachment (Roof to Wall) Part No. 620-XXX-14 Stone Coated Weight: 4.4 lbs (2.99 kg.) 120 (10 ft.) Lengths Rake/Roof to Wall Pce. Rake Cover Part No. 620-XXX-07 Stone Coated Weight: 3.5 lbs. (1.59 kg) 120 (10 ft.) lengths Rake/Roof to Wall Pce. Allmet Shingle Starter Strip Part No. 620-XXX-16 Stone Coated Weight: 7.11 lbs. (3.23 kg) 120 (10 ft.) Lengths 110 deg. Head Metal Part No. 620-XXX-18 Stone Coated Weight: 8.8 lbs. (4.00 kg) 120 (10 ft.) lengths Hip and Ridge Cap Part no: 620-XXX-02 Stone Coated Weight: 14.2 oz. (o.42 kg.) 14 length Pipe Jack Tray (Cut centre hole on site to suit) Part no: 620-000-14 Non-Stone Coated 14 x 14 Pipe Jack Flashing: Part no: See Inside Sales Coated or Non-coated 7

Shingle Installation Manual Materials One Piece Roof to Wall - Part No. 620-000-17 Non-stone Coated Weight: 4.73 lbs. (2.15 g) 120 (10 ft.) lengths Panel Fasteners (Installing contractor responsible to check local building code requirements in chosing panel fastener) Ring Shank Roofing Nails: 1-1/4 long min. Sufficient length to penetrate sheathing per code (min. 1/2 ) Screw: #9-10 x 1-1/2 (#9-10 x 38 mm) Part No. - Black 1000-30-18 - Coloured 1000-XX-18 *In high wind regions refer to local building codes and manufacturer applicable product evaluation reports. Stitch Screw for Valley Cap Only: Part No. - Black 620-000-15 - Brown 620-000-16 #8 x 1/2 E Z Vent for Shingles: Part No. 620-XXX-23 Ventilation Option for high wind regions Masterflash Part No. 000-000-33 Sealant Part No. 000-000-26 Professional thermoplastic sealant Super fexible Scellant thermoplastique profesional Super fexible 7 Rigid Roof Vent Part No. 620-000-13 20 ft. / roll Finishing Kit - Part No. 000-XXX-63 - Comprises of 8 oz. bottle base and 3 lbs. of colored stone chosen. 8

Estimating How to Determine How Much Material You Will Need Quick Step Method (approximate) 1. Determine roof square foot without waste. 2. Add linear feet of hips and valleys. Multiply by 2. 3. Add totals from steps 1 and 2. 4. Multiply total by 1.03. This yields roof square feet including waste. 5. Divide total from step 4 by 100. This yields roof squares. Allmet Shingle is 24 panels per square. Hip Length 21 Rafter Length 18 Overall Fascia Length 50 1) 50 X 36 = 1800 s/f w/o waste 2) Hip x 4 = 84 x 2 = 168 linear feet 3) 168 + 1800 = 1968 4) 1968 x 1.03 = 2027 5) 2027 100 = 20.27 sqs 9

Roof Preparation Allmet Shingles can be installed over low profile composition shingle or over solid sheathing with a minimum type 30 felt underlayment. If you choose to re-roof over lower profile composition shingles the procedures are as follows: 1. Cut back existing shingles flush with the perimeter of the roof. 2. Remove existing drip edge. 3. Remove hip and ridge cap. 4. Cover the entire roof with minimum of # 30 felt. Lay one additional layer of 30 lb. felt up the valley. If you live in an area where ice damming occurs use ice and water shield. At the valleys, weave the opposing courses of underlayment. Install underlayment on top of the starter strip. Starter Strip Underlayment over Starter Strip Nail Allmet Starter Strip Cut back existing shingles Fascia Allmet Starter Strip at Eaves 10

Rake/Roof-To-Wall and Felt Rake / Roof to Wall Deck with Underlayment Rake Cover Nailing @ approx. 16 o/c Rake or Gable End 5. Use a chalk line when installing the starter strip. Do not depend on the roof edge to be straight or square. Nail starter strip every 16 along the fascia line. Reminder - underlayment installed on top of starter strip. 6. Install the Rake/Roof to Wall up the gable or rake, fastening it where shown. It is sometimes easier to assemble the Rake Cover on to the Rake / Roof to Wall before installing. When done this way, shorten the first (bottom piece) of Rake Cover in order to prevent all the ends from lining up. Head lap is necessary for the Rake/Roof to Wall (approx 3 ). The Rake Cover should be notched at the top flange in order to achieve side lap 1-1 1/2 is sufficient. 7. Ensure that the bottom end of the Rake Roof to Wall overlaps the top flange of the starter strip and extends to or slightly beyond the lower edge of the starter strip. Place sealant between the lower edge of the rake roof to wall and the starter strip. 11

Valley Note: Ensure that the full width of the valley overlaps the top flange of the starter strip and extands slightly beyond the lower edge of the starter strip. Place sealant between the lower edge of the valley and the starter strip. Trim lower edge of the valley as needed. Fasten and seal in outer channel Place sealant 12

8. At the eave and starting from left to right, begin installing the Allmet Shingles. Take care to interlock the nose end of the shingle with the nose end of the Allmet Shingle Starter Strip. Nail the first course using seven nails per shingle along the nailing strip provided at the back of the shingle. 9. At the bottom of all rake roof to wall and valley runs, clip and fold under the nose of the shingle to allow for drainage. The drainage opening should reveal the full width of the rake roof to wall or valley. This is only done on the bottom course. The same procedure is done at the bottom of a valley to the raised V. (see diagram page11) 10. When installing any panel except for the first one in each course, it is very important to do the following: After positioning the panel on the roof and making sure the Pittsburgh lock is completely secure, place one hand on the left side of the shingle just below the center left step and with the other hand pull up on the top left corner of the same shingle and bend it up to at least 45 degrees. Then push the shingle back down, double check the Pittsburgh lock and fasten the panel in the same manner specified. This bending procedure will ensure that all of the side lap seams wil remain tightly closed. Ensure the integrity of the side lap before fastening the shingle. If the side lap does not close tightly, hand work the shingle until it does close tightly. 11. On all gable, roof to wall, and valley panels, snip off the top corner of the nail strip to 45 (gable panels would be snipped on the gable side - valley and roof to wall panels snipped on the cut side). At the bottom of these same shingles, make a v shaped notch on the bottom of the Pittsburgh lock 1 from the cut edge. 12. When installing Guardian or Granite Ridge panels it is very important to install the panels in uniformly straight course. Always be sure to apply each panel with the Pittsburgh locks completely connected. Not doing so could allow panels to become disconnected from each other and pop up, creating a problem. Starter Strip Fascia Shingle Diagram Staggered for clarification Shingle nailing pattern Notch Fascia Installed left to right Notch Shingle Installation Underlayment Side Laps 13

Roof-To-Wall, Head Wall and Valley Cap Detail Builder Installed Z-Bar Builder Installed Z-Bar Shingle Z-Bar Attachment Rake/Roof-To-Wall 110 Head Metal Rake/Roof-to-Wall 110 Head Metal Rake/Roof-to-Wall 110 Head Metal 13. Chimneys, skylights and roof to wall are flashed using the rake/roof to wall accessory along with the Z-bar attachment. The Z-bar attachment is snapped over the top of the Rake/ Roof to Wall Accessory Metal and inserted behind builder installed Z-bar. If there is nothing to slip behind, it becomes necessary to surface fasten and seal. Number and type of fasteners will vary with existing structural conditions. 14. Valley cap along with Char Filter Foam is placed over the Allmet valley concealing the mitered valley cuts and screwed every shingle course along the length of the valley cut to shingles with a #8 corrosion resistant screw. Take care not to penetrate the valley metal. 15. Install 110 Head Metal at front of the horizontal wall protrusion by putting one side behind builder installed Z-bar and other side Screw Chipped and Caulked Fascia Valley Cap with Char Filter Foam under cap. over the top of the shingles laid in a bead of caulk. If there is nothing to slip behind, it becomes necessary to surface fasten and seal. Number and type of fasteners will vary with existing structural conditions. 14

Hip and Ridge 16. The shingles above the eave course are installed by interlocking the nose end of the shingle with the back end (Pittsburgh lock) of the shingle of the preceding course concealing the nailing strip. 17. At the rake or gable end cut the shingles to fit and insert the cut edge into the Rake/Roof to Wall. 18. Hip and Ridge shingles are mitered to fit nailed and covered using the Hip and Ridge Cap. 19. Before installing Hip and Ridge Cap, place a strip of 5 to 6 inch wide Peel-N-Stick (high temperature) atop the cut hip and ridge shingles. Rake/Roof to Wall Accessory Metal Shingle Starter Strip Ridge Cap Rake Roof To Wall Notch area at bottom of gable or rake and fold under to allow for drainage. Rake Cover NOTE: Ensure Peel-N-Stick not exposed after cap installation. Optional Non-Vented Hip Detail Screws - Seal and Chip Hip Cap Mitre Cut Optional Hip Detail: Left side panel cuts off at hip intersection with the right side panel overlapping over the hip intersection and left panel by approximately 2 inches. Note: This detail can also be used for non-vented ridge. Screws - Seal and Chip 15

Riglet Installation Riglet - Set in a bead of Allmet caulk or equal or butyl tape. Fascia Starter Strip 20. The Allmet Riglet is available for use with installations involving an offset at the eave. The Riglet is aligned with the offset, set in bed of caulk and nailed on the back apron every six inches. THe shingles are then installedd on the main roof interlocking wiht the nose end of the riglet and laying over the top of the shingle below. 21. If you have difficulty closing some side laps, the following procedure is acceptable: Apply a 1-1/2, corrosion resistant hex head screw directly beneath the mid shelf of the shingle and approximately 3 to the right of the left side of the shingle.this screw is to be of sufficient length to pass completely through the roof sheathing. Do not over tighten or penetrate the overlapped shingle. Make absolutely certain you have followed the procedure outlined on page 18 - note 24. 16

Pipe Jack Installation.1.2 Sealant Pipe Jack Tray Pipe Jack.3 Weep-Hole Notch 22. Pipe Penetrations: Pipe Jack Tray inter- locks with lower Pittsburgh lock. Pipe Jack is is placed over the pipe and down onto the Pipe Jack Tray. Provide weep holes to protect against any future moisture that may enter in or around the pipe penetration. A weep hole is ceated by making two vertical cuts at the shingle nose approximately 1 apart. Fold the 1 tab back under the shingle. Seal where indicated..4 Sealant - Seal and Chip 17

Easy 5-Step Installation 1. Masterflash can be installed on-site quickly and easily, usually under 10 minutes. One piece construction makes Masterflash easy to handle. Bendable base forms seal with any contour, surface irregularities or roof pitch. Seals tightly and dependably with silicone sealant to eliminate costly call-backs. Pipe opening is easily customized with a sharp knife or scissors for any application. 2. Fix flashing to pipe with stainless steel hose clamp where snow load conditions exist. Master Flash - Option 1. Select and Trim Choose appropriate Masterflash with opening at least 20% smaller than pipe diameter. If necessary trim opening to 20% smaller than pipe diameter. 2. Slide Slide Masterflash down over pipe. (A non-petro - leum based lubricant will ease installation.) 3. 3. Form Press Masterflash down, bending it to conform to roof profile or roof irregularities. A blunt tool will help press flashing into tight roof angles. 4. Seal Apply sealant (NP1 or equal) between base and roof. 5. Fasten Use fasteners to complete sealing. 4. Note: Optional for further protection install Pipe Jack Tray per details 1 and 3 page 17 of Pipe Jack installation. Ensure sealing around roof pipe and Pipe Jack Tray prior to installing cover panel and Masterflash. 5. 18

Touch Up and Completion 23. Inspect the roof and touch-up all exposed screws using the provided touch-up kit. Remove all debris from roof and job-site. 24. Acceptable Repair Option Sealant Screw - Seal and Chip Fasteners Corrosion Resistant Screw Minimum #9-10 x 1-1/2 Side Lap Apply small bead of sealant between panels at side lap. Ensure sealant is not exposed outside of sidelaps. Draw panels together Do not over-tighten the screw fastener 19

Allmet Roofing Products TM P.O. Box 220 Property # 581, R. R. #2, Hwy #3 Courtland, Ontario, Canada N0J-1E0 P: 519-688-2200 F: 519-688-2201 T: 800-265-9357 E-mail: allmet@allmet.com Website: www.allmet.com Please Note: It is the responsibility of the installer to check the website for any updates or changes in the application of this product(s). 20