Four Carrier Signal Generator Operation Manual

Similar documents
c A T v s y s T E N\ BAND MODEL 6103 Head End Cable TEst Return IIHECTER/' MODEL 6106 Carrier Generator/ Telemetry Receiver Field Unit I'HECTER'S PUP"

TV SIGNAL LEVEL METER USER MANUAL

PAMS. User s Manual. Portable Attenuation Measurement System. The solution for making easy shielding effectiveness measurements.

Property of Ramsey Electronics, Inc. Do not reproduce or distribute.

I.D.A. Operation manual

CW Transmitter. User s Manual

Signal Generators for Anritsu RF and Microwave Handheld Instruments

INSTALLATION AND OPERATION GUIDE

User s Manual For PAMS. Portable Attenuation Measurement System /

DIGIAIR PRO USER MANUAL

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

RX1300 MULTIBAND SCANNING RECEIVER INSTRUCTION MANUAL

HP 33120A Function Generator / Arbitrary Waveform Generator

GETTING STARTED. Radio layout. LCD display with icons

Operators Manual For Spectrum Analyser SA97

TT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-

Dear Valued Customer,

QuickSyn Frequency Synthesizers

Digiair Pro ATSC USER MANUAL

Function Generator Guide Tektronix AFG3102

DT-800 中文 GB. Version 1

Welcome to the KNG-P150S

USER MANUAL. Model No.: DB-230

LT-700 Portable FM Display Transmitter

PathTrax. User s Manual. PathTrax. The solution for making easy shielding effectiveness measurements

1200 DPS Programmable Digital Powder System

Alemite FCS Fluid Control System

TABLE OF CONTENTS. Keypad Programming Manual 1

SDI SPECTRADYNAMICS, INC.

SDI SPECTRADYNAMICS, INC GHZ RUBIDIUM FREQUENCY SYNTHESIZER OPERATING MANUAL

SUNDIAL Light Dimmer. User's Manual

QAM Snare Snoop User Manual

Quiver User Guide. Xcor-QUG-v /13/12

RD1000 Ground Probing Radar

1510A PRECISION SIGNAL SIMULATOR

M O D U L E - 7 D Model CS-CAL/DLIU V6.0 Operator s Manual

DE1103 PLL FM STEREO/SW.MW.LW DUAL CONVERSION SYNTHESIZED WORLD RECEIVER OPERATION MANUAL

ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /

MULTIBAND SCANNING RECEIVER INSTRUCTION MANUAL

Localizer provides signal generation over the Localizer band of to MHz with 90 Hz and 150 Hz tones, amplitude modulated

Fluke 125. Getting Started. Industrial ScopeMeter

WE-525T Antenna Analyzer Manual and Specification

Contents ... What is DAB + Digital Radio?... 2 Setting up... 3 Backlit display... 4 Using headphones... 4 Your radio Switch off...

HPQI-2 QAM Pilot Generator Users Guide

Owner s Manual For Models G-225 & G-227 GMRS/FRS Radio

Model RVM Portable Radar Wave Velocity Meter

The LEBOW 7554 Operator's Manual 7.2

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

PORTABLE SPECTRUM ANALYZER WITH BUILT-IN SIGNAL GENERATOR. Arinst SSA-TG R2

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY SYNTHESIZER LNFS-400 OPERATING MANUAL

DEGEN DE1103 FM / MW / SW RECEIVER FM / AM / SSB / CW MODES OPERATING MANUAL

BASIC USER GUIDE BASIC USER GUIDE CONTENTS. GeneralInformation... 2

0.01kV (0 to ±0.99 kv)

Agilent EPM Series Power Meters

CSI 2140 Machinery Health Analyzer

ALAN 777 PMR 446 Radio Set User manual

2100L Broadband Power Amplifier

Agilent FieldFox RF Analyzer N9912A

Product manual UF-20R / UF-20S / JSS-20 / UF-20TB. Professional Wideband (75MHz) True Diversity System

Owner s Manual. Model G-223. GMRS/FRS Radio. FEATURES 22 Channels Scan 22 Key Pad Lock Call Alert Power HI/LO Roger Beep Tone

200 us/2 ms/20 ms/200 ms, TDS ( PPM ) Real time data logger, Data logger no., RS232 CONDUCTIVITY METER Model : YK-2005CD

Handheld Spectrum Analyzers, 3.3 GHz & 8.5 GHz Models 2650A, 2652A, 2658A

NACT TUTORIAL 3 FREQUENCY RESPONSE CALIBRATION

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

IFR 4000 Portable Nav/Comm Test Set

BeeLine TX User s Guide V1.1c 4/25/2005

USERS MANUAL TR-710.

_ Programming Manual RE729 Including Classic and New VoX Interfaces Version 3.0 May 2011

DC Electronic Loads 8500 series

FoxRex RigExpert. Made in Ukraine. User s manual. ARDF Receiver 3.5MHz

Fluke 123/124 Industrial ScopeMeter

GFL-1000 User Manual Ground Fault Locator

PSR-295. Portable Scanner OWNER S MANUAL

Spectrum Master MS2711D

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description

RigExpert AA-170 Antenna Analyzer (0.1 to 170 MHz) User s manual

APX Mobile and Portable Automated Test and Alignment

Better Music Builder POWER RF AF

JD723A/JD724B/JD726A Cable and Antenna Analyzers

Universal/Standard Ku-band GaN 40W BUC MODEL No. NJT8371 series

INSTRUCTION MANUAL FUNCTION GENERATOR FG-274 B

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

OWNER S MANUAL

LBI-38808B. Maintenance Manual EDACS UTILITY PROGRAMMING

Walkie-Talkie. User Manual and Instruction. Getting Started

SMART TWEEZERS Model ST-1 User s Manual Version 1.0

PMR446 Radio Instruction Manual

Advanced Test Equipment Rentals ATEC (2832)

MULTI-PURPOSE SCOREBOARD

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

Agilent N9340A Handheld Spectrum Analyzer

Talkabout T82/ T82 EXTREME OWNER S MANUAL

Universal/Standard Ku-band 8W BUC MODEL No. NJT8318 series

3100LA Broadband Power Amplifier

Contents. Controls Stereo / Mono setting - FM Battery operation Scan sensitivity setting - FM Using the AC adaptor...

Frequency and Time Domain Representation of Sinusoidal Signals

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Transcription:

ACE 5400 Four Carrier Signal Generator Operation Manual

Table of Contents 1. Features...2 1.1. Specifications...3 1.2. Connections...3 1.3. Controls and Connections...4 1.4. Keypad...4 2. Operating Modes...5 3. Run Mode...5 3.1. Basic Operation...5 3.2. Using the Numeric Keypad...5 Examples:...6 3.3. Using the Arrow Keys...6 Examples:...6 4. Setup Files...7 4.1. Saving a New Setup File...7 4.2. Recalling Stored Setups...8 4.3. Modifying An Existing Setup File...8 4.4. Starting a New File...8 4.5. Deleting Files...9 5. Setup Parameters...10 5.1. Contrast...10 5.2. Frequency Lock...10 5.3. Amplitude Units...11 5.4. Safety Timeout...11 5.5. Step Size...11 5.6. Shutdown Timer...11 6. Battery Charging...12 6.1. Battery Status Indicator...12 6.2. Battery Charge LED...12 6.3. Charger Cube...12 Page 1 of 12

1. Features The ACE 5400 portable RF signal generator has four agile carriers that can be activated individually or in any combination. The frequency and amplitude of each carrier is adjustable. The ACE 5400 generates CW signals that are stable and spectrally clean. It is ideal for testing and aligning CATV return paths and commercial and institutional networks. The ACE 5400 s basic and straightforward performance makes it ideal for applications that require a precise, stable RF stimulus. FEATURES Agile frequency settings (5 to 100 MHz in 10kHz steps) Agile amplitude settings (+30 to +50 dbmv in 1 db increments) Field portable, compact, rugged design Strong, fast charge, internal battery Easy to use keypad Carriers are activated individually Carriers are very stable and precise Output is spectrally clean Store and label multiple frequency plans STANDARD ACCESSORIES Padded carrying case and shoulder strap Transformer for charging battery, 120V or 230V Spare F connector Operation manual Page 2 of 12

1.1. Specifications Each of the Four RF Carriers: Type... Continuous Wave (CW) Frequency Range.. Tunable from 5 to 100 MHz in 10 khz steps Accuracy. Within 0.01% or 1.0 khz (the greater value) Amplitude Range.. +30 to +50 dbmv (90 to 110 dbµv) Selectable Increments.. 1 db steps Accuracy..... ± 1.0 db Spectral Purity... at least 55 dbc Output Impedance.... 75 Operating Temperature Range.. 0 0 F to 120 0 F (-18 0 C to +50 0 C) Internal Rechargeable Battery 1800 mah Operation Time per charge. 7 hours, continuous use Time to Recharge Battery 3.5 hours fast charge Enclosure Type High impact, molded plastic, Size. 8.5 W x 6.5 H x 3.25 D, 4.5 lbs Weight. (21.5cm x 16.5cm x 8.25cm, 3.63kg) 1.2. Connections 1) RF output 2) Battery charger input 3) Serial Port Specifications subject to change without notice Page 3 of 12

1.3. Controls and Connections 1.4. Keypad The keys are labeled with their primary function, but may provide extra functions indicated under the key. The P1, P2, P3 and P4 buttons primary function is to indicate the desired pilot carrier. In the setup screens, these are used as soft-keys to select various options. Key Primary Function Secondary Function ON / OFF Power on Power off FREQ (left arrow) Frequency entry backspace AMPL (right arrow) Amplitude entry (Up arrow) Incrementing values scrolling up (Down arrow) Decrementing values scrolling down SETUP / RUN Enter Setup Mode Enter Run Mode P1,P2,P3,P4 Pilot carrier selection Option selection ENTER Complete a field entry Turn backlight on/off Numeric keys Numeric entry Alphabetic entry. Decimal point When you are entering a file name, alphabetic characters are entered by pressing the indicated key once for the first letter, twice for the second, three times for the third and four times for the digit on the key. The key presses must be done fairly quickly. After a short delay without a key press, the cursor advances to the next position. If you make a mistake, you can back up with the left arrow key. Page 4 of 12

2. Operating Modes There are two operating modes of the instrument: Run Mode and Setup Mode. In Run Mode, you can turn pilots on and off and set frequency and amplitude. In Setup Mode you can save, restore and delete setup files and change other operating parameters of the instrument. The Setup Mode displays a scrolling list of features on the left and the options that can be selected for those features on the right. You select different features by moving the cursor with the up/down arrows. If there are more features than fit on one screen, the lines will scroll when you arrow up off the top or down off the bottom. The selected feature will be indicated by <> brackets around the present setting. 3. Run Mode The Run Mode is used for normal operation of the instrument. 3.1. Basic Operation P1 P2 P3 P4 Freq 10.00 20.00 30.00 40.00 MHz Ampl 30 40 50 50 dbmv ON off ON ON The main screen has one column for each pilot showing the frequency, amplitude and on/off state. The following operations are available: 1. You may turn any pilot on or off by pressing the P1, P2, P3 or P4 buttons immediately under the pilot column. 2. You may change any pilot amplitude using either the numeric keypad or the up and down arrows as described below. 3. You may change any pilot frequency using either the numeric keypad or the up and down arrows (also as described below). Note: the frequencies may be locked in the setup mode. If locked, you will not be able to change the frequencies without unlocking them first. 3.2. Using the Numeric Keypad To change the amplitude or frequency using the numeric keypad use these steps: 1. Press AMPL to change the amplitude or FREQ to change the frequency. A cursor should appear in appropriate field of the previously selected pilot. 2. Press P1, P2, P3 or P4 to select the pilot you want to change. You may skip this step if the desired pilot was previously selected. 3. Enter the value for the amplitude or frequency you want to set. 4. Press ENTER to save and set the value. If you enter a value outside the supported range, the closest available value will be used. Page 5 of 12

Examples: Set amplitude to a specific value Press: AMPL <pilot> <digit> <digit> ENTER Example: AMPL P1 4 5 ENTER Set Frequency: Press: Example: FREQ <pilot> <digit> <digit>. ENTER FREQ P2 8 7. 1 5 ENTER 3.3. Using the Arrow Keys To change the amplitude or frequency using the arrow keys: 1. Press AMPL to change the amplitude or FREQ to change the frequency. A cursor should appear in appropriate field of the previously selected pilot. 2. Press P1, P2, P3 or P4 to select the pilot you want to change. You may skip this step if the desired pilot was previously selected. 3. Press the up arrow to increase the value, or press the down arrow to decrease the value. The values will increase or decrease by the step size defined in the setup screen. Examples: Increment amplitude: Press: Example: Increment amplitude: Press Example: AMPL <pilot> <up/down arrows> AMPL P1 Up Up FREQ <pilot> <up/down arrows> FREQ P2 up up up Page 6 of 12

4. Setup Files You may save a combination of frequencies and amplitudes in a setup file for easy recall at a later time. For example, you may want to save a setup that is customized for a particular cable system. Every time you work on that cable system, you can simply recall the setup, avoiding the need to reset the frequencies. When a setup file is in use, the setup file name appears on the top line in place of the generic P1 to P4 column labels: (changed) NEWTOWN_CABLE Freq 5.00 13.00 31.00 57.00 MHz Ampl 30 30 30 30 dbmv ON off ON ON If the setup has been changed since it was last saved, (changed) will be indicated in the top left of the screen. 4.1. Saving a New Setup File Starting from a new setup (with the P1 to P4 column labels), or from a previous setup, reset the frequencies and levels to the desired values using the standard run screen as described above, then use the following steps: SETUP P1=Save Contrast: 400 P2=Save As Setup File:<NEWTOWN_CABLE> P3=File List Freq lock: LOCKED P4=New 1) Press SETUP 2) Press DOWN to position cursor on setup file line 3) Press P2 (Save As) 4) Enter a file name (alpha characters obtained by pressing the key multiple times) 5) Press ENTER Enter new file name Setup File: ENTER=store P4=cancel Page 7 of 12

4.2. Recalling Stored Setups To recall a setup that was previously stored: 1) Press SETUP 2) Press DOWN to position the cursor on the Setup File line 3) Press P3 to display the list of available files: Select File P1=Open <NEWTOWN_CABLE> P2=Delete CENTRAL P3=New EASTERN P4=cancel 4) Use the up and down arrows to select the desired file 5) Press P1 to open the file and recall the saved settings Note: if you had made changes that were not saved, you will be asked if you want the changes discarded. 4.3. Modifying An Existing Setup File Starting from an existing setup, reset the frequencies and levels to the desired values using the standard run screen as described above, then use the following steps: SETUP P1=Save Contrast: 400 P2=Save As Setup File:<NEWTOWN_CABLE> P3=File List Freq lock: LOCKED P4=New 1) Press SETUP 2) Press DOWN to position cursor on setup file line 3) Press P1 (Save) 4) When asked to confirm overwriting the existing file, press P1 for yes. 4.4. Starting a New File You can start a new setup and change the column labels back to P1 P4 as follows: 1) Press SETUP 2) Press DOWN to position the cursor on the Setup File line 3) Press P4 (New) If you had unsaved changes to the previously selected file, you can discard them or you are given a chance to save the changes first. Page 8 of 12

4.5. Deleting Files You may delete stored files with the following procedure. A confirmation window will pop up as a safety precaution. 1) Press SETUP 2) Press DOWN to position the cursor on the Setup File line 3) Press P3 to display the list of available files: Select File P1=Open <NEWTOWN_CABLE> P2=Delete CENTRAL P3=New EASTERN P4=cancel 4) Use the up and down arrows to select the desired file 5) Press P2 to delete the selected file 6) Press P1 when asked to confirm the deletion (or P2 to cancel) Page 9 of 12

5. Setup Parameters Setup files store frequency and amplitude settings but there are several other parameters that can also be changed in the Setup Mode. 5.1. Contrast The LCD contrast can be adjusted with the first setup parameter. If the contrast adjustment is way off, the screen may be all blank or all dark. If this happens, perform the following key press procedure carefully to adjust the screen until you can see it clearly. 1) Press SETUP SETUP Contrast:<400> Setup File: NEWTOWN_CABLE Freq lock: Locked P1=Change P2=Default 2) Press P1 (Change) SETUP Contrast:<400> Setup File: NEWTOWN_CABLE Freq lock: Locked = more = less ENTER=done 3) If the screen is too light (or blank) press the UP arrow until the characters are dark and the background is even. 4) If the screen is too dark, the area around each character will be dark and the character obscured. Press the DOWN arrow until the screen lightens and is easy to read. 5) Press ENTER to store the new setting 5.2. Frequency Lock You may lock the frequency settings to prevent accidentally changing them in the Run mode. Use the up/down arrows to select the Freq Lock line and press P1 to unlock or P2 to lock. Setup Setup File: NEWTOWN_CABLE Freq lock:<locked> Ampl Units: dbmv P1=Unlock P2=Lock Page 10 of 12

5.3. Amplitude Units You may change the units that the amplitude is displayed in. Use the up/down arrows to select the Ampl units line and press the key corresponding to the units you prefer. Setup Setup File: NEWTOWN_CABLE Freq lock: LOCKED Ampl Units:<dBmV> P1=dBmV P2=dBuV P3=dBm P4=dB(atn) With the db option selected, the instrument will display an attenuation value between 0 and 31.5 db rather than an absolute power level. This setting will let you change the level in ½ db steps but is not calibrated. 5.4. Safety Timeout The safety timeout terminates the edit mode when no buttons are pressed as a safety feature to help prevent accidental changes. This timeout can be changed. Select the line and press P1 to enter a numeric value. Or press P2 to restore the default (5 seconds). Setup Freq lock: LOCKED Ampl Units: dbmv Safety t/o:< 5> secs P1=change P2=default 5.5. Step Size The frequency and amplitude step sizes define the change when adjusting frequency or amplitude using the arrow keys. Setup Safety t/o: 5 secs P1=change Freq step:< 1.00> MHz P2=default Ampl step: 5 db 5.6. Shutdown Timer The instrument also has an inactivity shutdown timer that is enabled when the timeout value is set to something other than zero. The default is zero. Setup Freq step: 1.00 MHz P1=change Ampl step: 5 db P2=default Shutdown:< 0>Mins Page 11 of 12

6. Battery Charging The standard Nickel Metal Hydride (NiMH) battery pack will last for 500 to 1000 charge-discharge cycles, if properly cared for. The ACE 5400 has a fast battery charge circuit that charges the battery in approximately 4 hours. An overnight charge (6 to 8 hours) will continue charging until the battery is completely full. LEAVING THE CHARGER ON AFTER THE BATTERY IS COMPLETELY CHARGED WILL NOT HARM THE UNIT, BUT REMOVING THE CHARGER AFTER 12 TO 16 HOURS IS RECOMMENDED. 6.1. Battery Status Indicator In the lower right corner of the display, a battery charge indicator is shown. This indicator will either appear full (all dark), half full, or empty. The word (low) will flash to draw attention to the low battery condition. Full Half Empty When the Empty symbol is shown, the unit should be recharged. If the battery becomes too low to safely operate, the screen will be erased and a Low Battery message displayed. The instrument will then shut off after 5 seconds. 6.2. Battery Charge LED The battery charge LED shows the status of the battery charging circuit: OFF YELLOW GREEN charger is not connected charging battery nearly full and in a trickle-charge mode 6.3. Charger Cube The charger cube is rated at 120-250 VAC, 50-60Hz input and 24 VDC at 1.5 Ampere output with 2.1 mm plug. Using any device other than the provided charger cube may result in damage to the device and the ACE 5400. ANY ATTEMPTS TO CHARGE THE BATTERY WITH AN EXTERNAL POWER SOURCE OTHER THAN THE PROVIDED AC CHARGER CUBE MAY RESULT IN POOR OPERATION OR DAMAGE AND WILL NOT BE COVERED UNDER THE WARRANTY. Page 12 of 12