EPSITRON Electronic Circuit Breakers For Secondary Side DC Protection

Similar documents
EPSITRON Electronic Circuit Breakers Compact and Precise ECBs for DC Circuits

EPSITRON Advanced Power Supply System. High-Performance Meets High-Efficiency

Electronic Circuit Breaker BASIC FIX

PHOENIX CONTACT

Electronic Circuit Breaker BASIC SMART. - Number of available output channels: 2 / 4 / 8

Datasheet. Electronic Circuit Protection ESX10-T

PHOENIX CONTACT - 09/2009

Electronic circuit breaker ESS30-Sxxx-DC24V

Electronic Circuit Protector ESX10-T

Electronic Circuit Breaker ECONOMY SMART. - Number of available output channels: 2 / 4 / 8

Electronic Circuit Breaker ECONOMY REMOTE

PHOENIX CONTACT

Electronic Circuit Breaker with reset input ESS20-1..

MICO Solutions for Intelligent Power Distribution

Electronic Circuit Protector ESX10

EPSITRON Advanced Power Supply System Innovations

Power distribution system SVS25

Electronic Circuit Breaker ESS1 for System SVS1

Power Distribution System SVS18

ISOMETER IRDH575. Approvals

REX12 Electronic Circuit Protector

Electronic Circuit Breaker ESS1 for System SVS1

Current and Energy Measurement Technology Efficiency Is That Easy! Product Overview

1960 Research Drive, Suite 100, Troy, Michigan with. REVISION: December 10, 2007 (Supersedes previous versions) Prepared by:

Switching power supplies CP range, Linear power supplies CP-L range. Content

This data sheet is only valid in association with the IL SYS INST UM E user manual.

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Semiconductor contactors, Solid-state relays

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

QUINT-PS/ 3AC/24DC/10

Device circuit breakers Selective power distribution: branch out, individual adaptation, modular extension

02/11/2015

ECM3 EARTH CONTINUITY RELAY

02/11/2015

POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 )

Microprocessor Control Board Set Up Procedures (OR PLC)

Your Global Automation Partner. IMX12-DI01 Isolating Switching Amplifier. Safety Manual

ma. JUMPFLEX 857 Series. Transducers / Relay and Optocoupler Modules

Electronic Circuit Breaker ESS20-0..

CROSS Chassis from 160 A to 450 A

Protection components

Micrologic 5 and 6 Electronic Trip Units User Guide

POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 )

CP-T range Product group picture

Type CP-S, CP-C & CP-A Switch mode

Thermistor motor protection relays

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

Installation / Monitoring Technique

QUINT-PS/ 3AC/24DC/40

WINSTA The Connection System. Full Line Catalog 2010/2011

Switching relay terminal block; Relay with 1 changeover contact (1u); with miniature switching relay

Electronic circuit protector REX12

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

TeSys H. Protection. Motor controllers. Reliable. Motor starters. Contactors. Circuit breakers. Smart. Ultra-compact 22.5 mm motor starters

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

REX12 Electronic Circuit Protector

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

DATA SHEET. Paralleling relays, HAS-111DG ANSI code 25

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

MINI-PS AC/24DC/1.3

Industrial motor controller for brushed DC motors 12 VDC

Distribution/Substation Transformer

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

Power supply CP-T 48/20.0 Primary switch mode power supply

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

Power supply CP-T 24/40.0 Primary switch mode power supply

MULTI CONNECTION SYSTEM. Product Overview

Remote Radio Control. WAVE Push button radio control systems

CP-T range Benefits and advantages

QUINT-PS/ 1AC/24DC/20

Control module CP-A CM

American Power Design, Inc.

No-wear isolation of potentials in terminal block design

B850 Boiler House Energy Monitor

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

The wireless alternative to expensive cabling...

American Power Design, Inc.

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Industrial Electrician Level 3

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

E-STOP relays, safety gate monitors

200 RTH OFF ON IN OUT ALARM RESET

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Industrial motor controller for brushed DC motors 24 VDC

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

General technical data. Pollution degree 2. EMC / shock / vibration Noise emission acc. to EN Electrical safety (applied standards)

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

VersaMax Mixed Discrete / High-Speed Counter Module

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

LED converter Linear / area dimming. Uconverter LCAI 80 W 350 ma one4all V ECO

Transcription:

EPSITRON Electronic Circuit Breakers For Secondary Side DC Protection

WHY SECONDARY-SIDE PROTECTION? Switched-mode power supplies provide secondary side DC voltage to control circuits and loads such as PLCs, HMIs, and relays. When left unprotected, they are susceptible to hazardous ground faults. Protection devices such as fuses or conventional circuit breakers are often ineffective if your power supply cannot provide a brief overcurrent. Electronic circuit breakers provide a more precise and reliable mode of protection that complies with the EN 60204 Machinery Directive which requires secondary side faults to be switched off within five seconds. Power Supply Unit R Conductor R Fuse R Contacts K R Ground fault or R Short circuit Loop Impedance WHAT TYPES OF PROTECTION ARE THERE? t [s] 000 00 0 0. 0.0 0.00 5 5 t [s] 60 40 20 0, 0.0 B C D 3 5 20 30 t [s] 0. 0.0 0.004 4 A 7.5 2 4 6 8 5 I/I N I/I N I/I N Thermal Thermal and Magnetic Electronic Example: as found in NH and DP fuses High overcurrents required for fast tripping In the example: -fold overcurrent (related to the fuse nominal current): Tripping within range 30 ms (best case) or 200 ms (worst case) Only 2-fold overcurrent: Tripping within range 2 s (best case) or > 0 s (worst case) Found in circuit breakers or motor protection switches High overcurrents required for fast tripping In the example: 3... 5-fold overcurrent for B- characteristic and AC operation, additional safety factor.2 or.5 Thus, in the worst case a tripping current of 7.5 times the nominal current is necessary Ensure precise settings Reaction within a short time even at low overcurrents Protection of long cable runs and small cross sections possible NH fuse = Low-voltage, high-power fuse DP fuse = Device protection fuse

Adjust HOW DOES AN ECB FUNCTION? The ECB verifies that the output current is greater than the nominal current. As soon as the output current exceeds the nominal current, the output is electronically switched off by a semiconductor. The trip time depends on the magnitude of the overcurrent. The measurement of the output current, processing and calculation of the tripping time, as well as actuation of the semiconductor are performed by a microprocessor that monitors one or more output channels. The corresponding tripping times can be taken from the graph on the right. t [s] 0. 0.0 7.5 0.004 4 A.5 2 3 4 5 6 8 5 20 30 I/I N ECB ADVANTAGES Switch off secondary-side overcurrents and short circuits even with long cable runs and small conductor cross-sections precisely, fast and repeatedly Remote reset via digital input and output Communication through serial data transfer via digital input and output or IO-Link Space saving design - save up to 70% on the DIN rail Adjustable nominal current for each channel Satisfy EN 60204- requirements for dependably switching off ground faults after five seconds (see right) DC OK Overload EPSITRON ECO Power, 787-732 ECB, 787-664 Motor

EPSITRON ELECTRONIC CIRCUIT BREAKERS Single-Channel

Tripping Time 0.6 0.4 0. 0.06 0.04 0.02 0.0 0.006 0.004 0.002 0.00.3.45.2.5.5 2.0 2.5 3.0 3.5 7.5 Push-in CAGE CLAMP Connection Terminate solid and ferruled conductors via Push-in CAGE CLAMP Connections - no operating tool needed Operating tool for installing and removing all conductor types Easy Jumpering Signal output can be jumpered for up to 30 devices Jumpering signal level allows reset of circuit breaker channels Intuitive Status Indication Integrated, multi-color LEDs indicate the operating status of each channel Push/slide switch for switching on/ off, as well as set/reset Minutes Seconds Trip Characteristics Reliable, rapid and precise switching in case of overcurrent or short circuit High switch-on capacities >50,000 µf prevents false tripping Rated Current Industry s Most Compact True 6.0 mm width maximizes panel space Marking Options Via WMB Markers or TOPJOB S Marking Strips Devices are color-coded according to nominal current Versatile Configuration Options Optional nominal current setting... 8 A, in A increments ECBs vs. Thermal Magnetic Circuit Breakers More reliable trip curve Local and remote set/reset capabilities Space savings: 6 mm vs. 2.5 mm Reduce wiring time by jumpering Solid state device will never wear out

EPSITRON ELECTRONIC CIRCUIT BREAKERS Multi-Channel

0 Adjust DC OK Overload Pluggable CAGE CLAMP Connection Technology Fast, vibration-proof, maintenancefree For solid, fine-stranded and ferruled conductors 0% protected against mismating With marking Rotary Switch Nominal current can be individually adjusted for each channel The setting is visible, even when no voltage is applied Transparent cover can be sealed and marked Status Indication Each output channel has backlit buttons for switching on/off, as well as acknowledgement Integrated, multi-color LEDs indicate the operating status of each channel Selective Immediate Deactivation If the upstream power supply overloaded and the voltage drops, the ECB immediately shuts down the responsible channel to avoid affecting parallel channels Auslösezeit (ms) 0000 3 A 6 A A 4 A 8 A 000 00 0 Ausgangsstrom (A) Trip Characteristics Reliable and precise disconnection in case of overcurrent or short circuit Nominal currents can be set separately for each channel Tripping time can be configured in defined increments Optional, active short circuit current limitation* to.7 times the nominal current prevents a voltage drop in other current paths *Only for 787-66x/xxxx-xxx Communication.0: Both high-side and low-side switching digital inputs and outputs are available. There are also variants with potential-free signal output 2.0: Using the Manchester pulse train, data can be read out of the device via digital inputs and outputs. For details, see page 8. Digital output S3 continues to serve as the sum signal for the tripped message 3.0: IO-Link interface: In addition, the rated currents can be set via communication Marking Device identification via WMB Markers or WAGO TOPJOB S Marking Strips Label individual channels via marking strips that can be inserted into the rotary switch cover from the outside

COMMUNICATION Electronic Circuit Breakers (ECBs) Communication.0 Digital Signaling (S/P/LS) The electronic circuit breaker can be reset via a digital control signal. The 787-286 ECB can also be switched on and off via this signal. A digital output signal indicates the status of the channel or the sum of the channels for 787-66x. For some devices this signal is potential-free (P) or low-side switching (LS). Communication 2.0 Manchester Protocol (M) The PLC transmits a coded pulse pattern to control input S. The ECB synchronizes itself automatically. The current status of all output channels is transmitted back simultaneously via signal output S2. The edge change is interpreted as high or low. For each channel, both status, voltage and current values can be transmitted individually. Communication 3.0 IO-Link (I) Via an IO-Link interface implemented in COM3, both status, voltage and current values can be transmitted individually for each channel. The nominal current of the output can also be configured via this interface if the device s rotary switch is set accordingly. The IO-Link cyclic communication is much faster compared to the Manchester protocol. S = Signal LS = Low-side switching signal P = Potential-free signal I = IO-Link protocol M = Manchester protocol

Function blocks for ECB monitoring that use the WAGO-I/O-SYSTEM, or different control systems, are available for free. EPSITRON Series ECBs have digital inputs and outputs that provide communication via the Manchester protocol. All channels can be diagnosed and switched remotely independently of each other. Transmission of: State per channel Current output current (only for 787-66x/xxxx-xxx and 787-66x/xxxx-xx8x) Nominal current setting per channel Input voltage Power on/off and reset per channel Nominal current setting (only for 787-66x/xxxx-xx8x) Available Function Blocks: WAGO-I/O-PRO (CODESYS) WAGO e!cockpit Siemens S7/TIA Portal Schneider Rockwell Automation Mitsubishi (pending)

EPSITRON ELECTRONIC CIRCUIT BREAKERS 97.8 90 90 27 6 94 5.5 45 5.5 45 42.5 42 Input/Output Approvals Dimensions and Environmental Conditions Nominal input/output voltage (VDC) Output channels Nominal output current (ADC) Communication Active current limitation UL 6 UR 2367 culus 508 GL Width (mm) Height (mm) Length (mm) Operating temperature ( C) NEC Class 2 S = Signal LS = Low-side switching signal P = Potential-free signal I = IO-Link protocol M = Manchester protocol Further information on ECBs communication options can be found on pages 8-9. yes Item Number pending S 6 97.8 94-25... +70 787-286/0-000 2 S 6 97.8 94-25... +70 787-286/200-000 24 4 S 6 97.8 94-25... +70 787-286/400-000 6 S 6 97.8 94-25... +70 787-286/600-000 8 S 6 97.8 94-25... +65 787-286/800-000... 8 S 6 97.8 94-25... +70 787-286/8-020 2 2... M 45 5.5 90-25... +70 787-662 2 2... P 45 5.5 90-25... +70 787-662/000-054 24 2 3.8 LPS M 45 5.5 90-25... +70 787-662/004-00 2 0.5... 6 M 45 5.5 90-25... +70 787-662/006-00 2... 6 M 45 5.5 90-25... +70 787-662/6-000 4 2... M 45 5.5 90-25... +70 787-664 4 2... M 45 5.5 90-25... +70 787-664/000-004 4 2... P 45 5.5 90-25... +70 787-664/000-054 4 2... N 45 5.5 90-25... +70 787-664/000-0 4... I 45 5.5 90-25... +70 787-664/000-080 24 4 3.8 LPS M 45 5.5 90-25... +70 787-664/004-00 4 0.5... 6 M 45 5.5 90-25... +70 787-664/006-00 4... 6 M 45 5.5 90-25... +70 787-664/6-000 4... 6 N 45 5.5 90-25... +70 787-664/6-0 4 2... 2 M 45 5.5 90-25... +70 787-664/22-00 4 0.5... 6 P 45 5.5 90-25... +70 787-664/006-54 8 2... M 42 42.5 27-25... +70 787-668 8 2... M 42 42.5 27-25... +70 787-668/000-004 8 2... P 42 42.5 27-25... +70 787-668/000-054 24 8... I 42 42.5 27-25... +70 787-668/000-080 8 0.5... 6 M 42 42.5 27-25... +70 787-668/006-00 8... 6 M 42 42.5 27-25... +70 787-668/6-000 8 0.5... 6 P 42 42.5 27-25... +70 787-668/006-54 2 4 2... M 45 5.5 90-25... +70 787-664/000-0 2 2... P 45 5.5 90-25... +70 787-662/000-250 48 4 2... M 45 5.5 90-25... +70 787-664/000-200 4 2... P 45 5.5 90-25... +70 787-664/000-250 48 8 2... M 45 42.5 27-25... +70 787-668/000-200 8 2... P 42 42.5 27-25... +70 787-668/000-250

Model Code Key: EPSITRON Series 787-xx6a/bbcc-defg Design ECB Number of channels Lower nominal current (00: 0.5 A; 0: A; 02: 2 A) Upper nominal current (04: 3.8 A; 06: 6 A; 2: 2 A) With () or without (0) active current limitation Nominal voltage (0: 24 VDC; : 2 VDC; 2: 48 VDC) With (5) or without (0) potential-free contact; (2) settable single-channel variant Configuration (0: standard; 4: with group message tripped and switched off; 5, 6: customer specification For more information, visit www.wago.us/whyecb

60372680 0888-0832/0000-0373 06/208 - Printed in the United States