WEARABLE WIRELESS ADAPTIVE REFRACTOR

Similar documents
Wearable Adaptive Refractor. Innovative, Electronic, Mobile and Wearable System of Adaptive Lenses.

2Win Binocular Mobile Refractometer and Vision Analyzer

Marco TRS Total Refraction System

Intelligent Refractor RT-5100

ERK-9000 Auto Ref/Kertometer

Intelligent Refractor RT-5100

Tabletop Refraction System TS-310

Visual acuity finally a complete platform

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST - KEY

Refractive Power / Corneal Analyzer. OPD-Scan III

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST

SPHERE, CYLINDER, AXIS, and ADD Power: Why these four variables? Example Prescriptions: UNDERSTANDING A PRESCRIPTION SPHERICAL LENSES 8/31/2018

Versatile Functionality RT-5100 SMART REFRACTOR

Auto Ref / Keratometer ARK-560A / 530A / 510A

HRK-7000 / HRK-7000A Auto Ref-Keratometer

Eschenbach Low Vision Training Program

OPH 260 BASIC CONTACT LENS CONCEPTS

Agenda. 1. EyeLT Step 1 2. EyeLT Step 2 3. EyeLT Step 3

AUTO REF / KERATOMETER ARK-560A / 530A / 510A

3/31/2016. Presented by: Bob Alexander, ABOM/NCLE-AC Lens Consultant Vision Ease. Everywhere and Sportwrap; Understanding Digital Technology

PREMIUM LENSES WITH VARIABLE BASE CURVE

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Keeler Direct Ophthalmoscopes

Distribution of Refractive Error. 20 year old males. Distribution of Aberrations

Faster, Easier and More Accurate AUTO LENSMETER LM-1200/1000(P)

UNITY VIA PROGRESSIVE LENSES TECHNICAL WHITE PAPER

HEINE Direct Ophthalmoscopes

3/6/2014. Because: Answer: Early studies comparing acuity with spectacles vs. scl or rigid cl s

VARILUX FITTING GUIDE GUIDELINES FOR SUCCESSFULLY FITTING VARILUX LENSES

DESIGN OF GAUSSIAN SPATIAL FILTER TO DETERMINE THE AMOUNT OF REFRACTION ERROR IN HUMAN EYE

Page 1

Create a number line. Determining cylinder power

Learn Connect Succeed. JCAHPO Regional Meetings 2017

continuing education course Approved by the American Board of Opticianry

Multiple-Choice Questions

Astigmatism. image. object

An Application of Lenses: The Human Eye. Prof. Jodi Cooley Supplementary Material for PHY1308 (General Physics Electricity and Magnetism)

Smart Refractor RT-5100

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Where s my lens clock? Where s the base curve? F1 (front) or F2 (back) surface? Red or black scale?

Excellent Measurement Accuracy ARK-530A / 510A AUTO REF / KERATOMETER

Dispensing 1. Prepared by Hatem S.H. Barhoom MHSC (clinical optometry) UKM Malaysia

THE ONLY PORTABLE, AFFORDABLE INSTRUMENT OFFERING THREE-DIMENSIONAL VIEWING AND ILLUMINATION INTO A SMALL CAVITY.

digital lens designs

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

Low Vision Math Made Easy for the Primary Care Optometrist

Optical Perspective of Polycarbonate Material

Properties of optical instruments

Small lens. Great freedom.

Copyright 2016, Phernell Walker, BSB, ABOM

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

SOFT (HYDROPHILIC) CONTACT LENSES DAILY WEAR FOR PLANNED REPLACEMENT OR DAILY DISPOSABLE. PRACTITIONER FITTING GUIDE July 2009

Guide To Purchasing Glasses Online By. Spex4less.COM PREMIUM EYEWEAR

FITTING GUIDE. Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near

Impression - Individual Lenses from Rodenstock.

LM-1200 / 1000(P) AUTO LENSMETER

Slab Off or Bicentric Grinding

Concepts of Optics Quiz. 8. Spherical lenses focus along a single point; cylindrical lenses focus along a.

KODAK Unique DRO Progressive Lens BE UNIQUE IN YOUR MODERN WORLD

Custom Solutions Catalog Prescription Corrected Solutions For Your Most Challenging Patients

SYSTEM CHART SC-1700 Pola / 2000

Today s subject Auto Refractometer & Auto Ref / Keratometer AR-1 & ARK-1

Chapter 3: LENS FORM Sphere

HEINE BETA 200S Ophthalmoscope

055_056_varilux_divider.indd 55 VARILUX VARILUX

HEINE QUALITY. :- HEINE Hand-held Ophthalmic Instruments

FOR PRECISE ASTIGMATISM CORRECTION.

HOW WE LL PROCEED. I ll put up a statement. You guess the answer Yes no True-false. You Focus the Lensometer Using the Target Circles.

Basic Principles of the Surgical Microscope. by Charles L. Crain

Optics of the Human Eye

LuxIQ Diagnostic System Reference Guide

Instruments Commonly Used For Examination of the Eye

5 Easy Steps to Purchasing Glasses Online

Handheld Ref/Keratometer / Handheld Refractometer HandyRef-K / HandyRef

The First True Color Confocal Scanner

AO TECHNICAL REPORT A STUDY OF LENS CONSTRUCTION AND USE AMERICAN OPTICAL CORPORATION SOUTHBRIDGE, MASSACHUSETTS 01550

ABO Certification Training. Part II: Basic Optical Principles

Contact Lenses Didn t Work! Now What? Evaluation and Treatment of Aniseikonia

A Checklist for Managing Spectacle Lens Complaints. Presented By: Raymond P. Dennis, M.A. (Ed.) Middlesex Community. Patient Complaints

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Optical Characteristics of Next Generation Dual Optic IOL

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

Impressive Wide Field Image Quality with Small Pupil Size

Vision Shaping Treatment

Fax: (800) Phone: (800) Fax: (800)

Technology Reference guide. March 2011

The people-based design

The First True Color Confocal Scanner on the Market

MPH150 USER MANUAL 1 - V 150E H P 07/2013 M M U

INTRODUCTION TO LENSOMETRY

WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION. Cataract treatment

MOTOTRBO SL3500e PORTABLE TWO-WAY RADIO. BROCHURE SL3500e

HEINE Direct Ophthalmoscopes

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

AMCON LENSOMETER USER S MANUAL EQ Fax

CATARACT SURGERY AND DEPTH OF FIELD (D.O.F.)

Auto Ref / Kerato / Tono / Pachymeter TONOREFTM III

The First True-Color Wide-Field Confocal Scanner

An Interesting Use of Bausch and Lomb s KeraSoft IC Lens

Transcription:

B H WEARABLE WIRELESS ADAPTIVE REFRACTOR REVOLUTIONIZING SUBJECTIVE REFRACTION A vision that inspires yours

REVOLUTIONIZING THE MEASUREMENT OF SUBJECTIVE REFRACTION VisionFit is an innovative electronic, tunable, all-in one, solid state, mobile and wearable system of lenses. It performs a subjective sight examination and it effectively replaces both the trial glasses and the manual/electronic phoropter functionality. FEATURES Adaptive Lenses Diopters Increment Down to 0.05D Wider Peripheral Vision Wearable and Mobile Versatile and convenient Connectivity Portable and Rechargeable Control Panel Operated Print Capabilities

THE EVOLUTION OF SUBJECTIVE REFRACTION 1880 1900 1965 2000 2015 The technology implement in the VisionFIt was develop in the University of Padova, the second oldest university worldwide, in the same Astronomy department where Gallileo Galilei design the first telescope. Through the years, the University of Padova specialized in adaptive optics and optoelectronics applied to Industry and astronomical research. Leveraging on its technological know-how and competences in Astronomy going from the macro-cosmos to explore the micro-cosmos of the human eye.

ADAPTIVE LENSES ADAPTIVE LENSES The VisionFit Adaptive Lenses revolutionary spherical and cylindrical lens technology operates under a very similar principle to the human crystalline lens. Similar to the human crystalline lens, the VisionFit has the ability to adjust and change dioptric power while being controlled electronically by the operator. This allows for a more accurate and fluid subjective-sight examination process for both the operator and the patient. DIOPTERS INCREMENT One of the greatest benefits of the VisionFit Adaptive Lenses is the high-precision single lens technology. With just one lens, the professional has a full range of dioptric values with astonishingly precise incremental steps of 0.05D. This incredible accuracy is achieved by the unique adaptive lens technology which is linearly designed to mimic the human crystalline lens making the VisionFit an unparalleled tool for refractive surgeons. Another great benefit is its instant response to electronic stimuli, this makes the process of preparing the patient s prescription fast and accurate. Cutting down the examination process and increasing examination accuracy is our main objective.

WIDER PERIPHERAL VISION Due to the VisionFit s slim and compact design, the peripheral vision is wider than any other phoropter available. This feature makes VisionFit the new concept for subjective refraction. By increasing the peripheral range this not only opens the door to a variety of new testing capabilities, but also allows the patient to have more confidence in the accuracy of their final prescription glasses. ELECTRONIC TRIAL FRAME Adaptive Spherical Lens Adaptive Cylindrical Lens Add-On Lens Support

WEARABLE AND MOBILE Subjective refraction can be performed with the patient in any position due to the mobility of the unit. This allows the patient to move freely around the room to accurately test how the patient will feel with the final prescription. This increased amount of mobility creates a more comfortable procedure for both the patient and operator.

VERSATILE AND CONVENIENT The VisionFit allows for an increased amount of versatility regarding examination room layout. By eliminating bulky refractory stands, more space can be utilized for additional needs. The versatility of this modern device, allows a comfortable experience for all patients including those who may use large wheelchairs. The device s unique portability eliminates the large refraction unit or special installation procedures to receive the desired results. The patient wears the VisionFit lens frame like a regular trial frame and looks through it at a standard eye chart or any other near or far target. While the patient is examining the chart, the operator will adjust the position and configuration of the optics with the user-friendly control panel application.

VisionFit Software App 2WIN *All items are sold separately CONNECTIVITY The VisionFit, being the top-of-the line subjective refraction system, utilizes Wifi and Bluetooth connection to synchronize with the 2WIN as well as the control panel. This wireless system also eliminates the problems caused by excess cords that may get in the way of the patient and operator. The device can also be controlled remotely by the operator, which provides the most feasible and versatile option for diagnostic and service needs. Allowing the doctor to work at the comfort of his desk. Due to the fast and reliable wifi connection, the VisionFit can receive 2WIN objective Rx data which will minimize the examination process. The bluetooth functionality of the equipment makes it easier than ever to pair with any Android tablet. Standard cord connection is also available to the user. PORTABLE AND RECHARGEABLE The VisionFit allows the professional to accommodate his entire refraction practice in a single carry-on that can be taken immediately to practice everywhere. To ensure the portability and functionality of the VisionFit SC, equipped, with a rechargeable and replaceable battery pack. This battery pack provides a 2-3 day charge, which allows the doctor peace of mind that his equipment will be available to use when needed. The ability to use the device over and over without a charge is as incredible benefit for fast-paced ophthalmic clinics.

CONTROL PANEL OPERATED To accommodate existing devices of the practice, the VisionFit system is controlled by an app that can be downloaded on any Android tablet. The tablet serves as control panel that can receive data from 2WIN and allows the operator to adjust power diopters, axis, JCC and much more. Another benefit to the usage of an app is the constant upgrading of its software, allowing the professional to always have the latest and greatest technology available to their practice. Exam Date: Thu Aug 24 2017 Exam N: 8 VISION FIT REPORT VISION FIT REPORT Exam Date: Thu Aug 24 2017 SUBJECTIVE EXAMINATIONS: Exam N: 8 EXAM CODE:#1: Last Subjective Examination Date:Thu Aug 24 13:50:08 2017 SUBJECTIVE EXAMINATIONS: OD EXAM CODE:#1: Last Subjective Sph Cyl Ax +0.750 91 0.000 OD Examination Date:Thu Aug 24 13:50:08 2017 Sph Cyl -0.250 Add OS +0.250 Ax -0.500 Add 111 OS 0.000 PRINT CAPABILITIES VisionFit provides incredibly versatile prescription printing options, which allows the results to be shared with email, message, Bluetooth, and wifi. This variety accommodates different practice needs. It provides four output files that can be viewed or transferred. These files include two PDFs for prescription screening result and detailed subjective refraction Regarding EMR needs, JSON files and XML files are also provided. Cyl BU Acuity:- +0.250-0.500 111 VD:0.0 Prism:0.0 BU Acuity:- PD:66.3 REFERENCE EXAMINATIONS: NOTES: Sph Prism:0.0 Ax BU Acuity:- +0.750 PD:66.3 Sph Prism:0.0 Ax -0.250 91 0.000 Prism:0.0 BU Acuity:- VD:0.0 REFERENCE EXAMINATIONS: NOTES: CODE:2Win(145) #1 OD EXAM CODE:2Win(145) #1 Sph Cyl Ax +1.500 Examination Date:Thu Aug 24 13:42:21 2017 91 0.000 OD Sph Examination Date:Thu Aug 24 13:42:21 2017 Sph Cyl -0.500 Add OS Cyl +1.000 Ax +1.500 Ax -0.750 111 Add 91 0.000 Sph Cyl -0.500 Add OS 0.000 +1.000 Ax -0.750 Add 111 0.000

ADJUSTABLE REFERRAL THRESHOLD With the combination of the VisionFit SC and the 2WIN binocular handheld refractometer and vision analyzer, the operator can perform an objective and subjective refraction exam in only a few minutes. By introducing this wireless, wearable, light-weight, and highly innovative device to the medical space, we envision a minimalistic and modern future to clinical ophthalmic examinations. The stylish simplicity of this refraction system, mixed with an increased accuracy of results, makes the VisionFit a cutting-edge addition to the future of diagnostic technology.

VISIONFIT FEATURED BENEFITS Wearable and mobile - it fits just like a trial frame Adjustable step resolution down to 0.05 D Enables examining in free posture Small footprint and reduced exam time Increases peripheral vision Doesn t require control of the patient s position Ideal with non-cooperative patients and handicap Connectivity, broad recording and printing capabilities Faster and more efficient than the standard digital phoropter Does not require any infrastructure nor refractory unit Subjective refraction can be performed in association with other biomedical devices

WEARABLE WIRELESS ADAPTIVE REFRACTOR Revolutionizing the Measurement of Subjective Refraction SPECIFICATIONS -10/+10 D and -20/+20 D with the use of an additional lens with prescription Spherical Correction Range steps of 0.125 D and variable fluidity steps (adjustable from 0.05 to 0.25 D) with the use of the basic spherical lens. Cylindrical Correction Range 0 to 10 D by steps of 0.25 D Axis Adjustment Range 1-180 by steps of 1 Additional Prismatic Lenses Range (optional) 0 to 10 Δ, steps 1 Δ (add on no automatic) Corneal Vertex Distance Range 0.4-0.7 in (10-18 mm) Manual Pupil Distance Adjustment Range 1.97-3.15 in (50-80 mm), separated right and left Device Free Aperture 30 degrees Display Tablet 9.6 inches multiple touch Bluetooth Module BT 4.0 low energy Power Battery powered LI-ION 3400mAh NCR18650B (Polarized type, BottomTop) 4 cells Battery Charger AC-DC Medical Converter 24V 60W www.usophthalmic.com Ph: 1.786.621.0521 info@usophthalmic.com Distributed by: