General Installation Instructions LED

Similar documents
Healthcare LED TROFFER FLANGE (HSTLED Family)

EZY Curb INSTALLATION INSTRUCTIONS

General Installation Instructions

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

WARNINGS AND INSTRUCTIONS FOR LUMINAIRES

WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

LINESSE LINEAR LUMINAIRE 3 RECESSED CV2424

MaxLite Linear Strip ECO Series

LINESSE LINEAR LUMINAIRE 3 CEILING MOUNT CM2420

EOS LED Surface Mounted Luminaire

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

EOS Direct/Indirect LED Pendant Luminaire

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

Lightplane 3.5 Recessed

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

EOS Linear LED Recessed Luminaires

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

Maintenance and other important non-personal injury and non-material damage instructions or statements that should be observed.

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

HP 2 SERIES Integral Driver - Solid State LED

GLASS GLOBE MOBILE LINEAR CHANDELIER

Linear LED Recessed Luminaires

WARNING. Failure to observe these instructions could lead to severe injury or death.

CAUTION: BEFORE INSTALLING THE LUMINAIRE, MAKE SURE THAT THE CURRENT IS CUT TO THE BOX FUSES / MAIN CIRCUIT BREAKER.

Round or Square Chicago Plenum Down Light Housing with Lamp

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

Curium 19H Installation Instructions & Parts List

INSTALLATION INSTRUCTIONS

Pow-R-Feed Systems Service Manual

SAVE THESE INSTALLATION INSTRUCTIONS

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

DAWN TO DUSK SENSOR OWNER S MANUAL

Bionic 4 PERIMETER, CONTINUOUS RUN X3, X7

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

HR175 Sash Replacement Kit Installation Instructions

SUPPLEMENTARY INSTALLATION INSTRUCTIONS Ventilating Fan (Contractor Pack)

ZIP CLOUD SUSPENDED INSTALLATION MANUAL

Nash Chandelier Assembly and Installation Instructions

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

LOTBLASTER 65W 110W 160W INSTALLATION INSTRUCTIONS

Installation Instructions

Woven Leather Chandelier Large Assembly and Installation Instructions

Curium 19.4H Installation Instructions & Parts List

Continuous Handrail Kit Installation Instructions

Installation Instructions

MESO X1 TBAR SEMI-RECESSED

Installation Instructions: T-Lite LED Signage Tube Lamps

INSTALLATION INSTRUCTIONS

Sliding Door Kit

Fabric tiered drum pendant 30in Assembly and Installation Instructions

M MODULAR PARTS T01-A INSTALLATION INSTRUCTIONS MIRRORED CABINET W/DEFOGGER K-15512T , 2011 Copyright Kohler China Ltd.

-Always de-energize the circuit and/or equipment before connecting to, disconnecting from or servicing the equipment.

WEAR SAFETY GLASSES WHEN INSTALLING THIS KIT.

INSTALLATION INSTRUCTIONS

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

INSTALLATION INSTRUCTIONS LARGE FLAT PANEL IN WALL ENCLOSURE Model: PAC-500

INSTALLATION INSTRUCTIONS

GLASS GLOBE MOBILE 6-ARM CHANDELIER

INDIVIDUAL MOUNTING: T-Bar

Gallium 03 Installation Instructions & Parts List

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS

Riverside. Windward Bay EntertaInment Wall System Assembly Instructions. Made In Viet Nam. Right Pier. Bridge & Back Panel.

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

Custom Pendant- Hardwire Assembly and Installation Instructions

SLOT INSTALLATION GUIDE Indoor IP20

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

LED Thin Frame Fixed Frame Screen User Guide

M MODULAR PARTS T01-A INSTALLATION INSTRUCTIONS MIRRORED CABINET SIMPLIFIED LEFT OPENING DOOR K-15512T-NL RIGHT OPENING DOOR K-15512T-NR

Xenon 05 Installation Instructions & Parts List

Radon 07 Installation Instructions & Parts List

MADELINE METAL CHANDELIER

Dubnium 11 Installation Instructions & Parts List

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

QWALL 5.2 (2 Back Panels)

PORTROD WALL MOUNTED HEIGHT ROD

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

Frameless Inline Door With Return QCI5263

MTS-SP100. RENOGY Pole Mount System E Philadelphia St, Ontario, CA Version: 1.2

ALWAYS TURN FIXTURE OFF/DISCONNECT POWER AND ALLOW TO COOL BEFORE PERFORMING ANY MAINTENANCE, INCLUDING RELAMPING AND CLEANING!

ROPE CHANDELIER - FRAME ASSEMBLY & INSTALLATION INSTRUCTIONS

REGATTA PATH LIGHT (RGP)

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.

INSTALLATION INSTRUCTIONS

Step-by-Step Installation Instructions for

SHOWER DOORS INSTALLATION INSTRUCTIONS SHOWER DOORS: LBSDD Version 4.0

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

End Plate Alignment Pin 80-PIN Paint Mask 35-EXT Plexineon Mounted in Extrusion. Extrusion 75-EXT

Basic Spring Motor Roller Shades

INSTALLATION INSTRUCTIONS FOR STANDING SHOWER CABIN OWNER'S MANUAL PLEASE READ INSTRUCTIONS BEFORE PROCEEDING Packing List. Door (pc) 2. Hinge (2pc) 3

Installation Instructions

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

PORTABLE HALOGEN WORK LIGHT OWNER S MANUAL

Transcription:

General Installation Instructions LED To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions and other hazards, please read all warnings and instructions included with and on the luminaire box and all luminaire labels. Before installing, servicing or performing routine maintenance upon this equipment, follow these general precautions. Installation and service of luminaires should be performed by a qualified licensed electrician. Maintenance of the luminaires should be performed by person(s) familiar with the luminaires construction and operation and any hazards involved. Regular luminaire maintenance programs are recommended. It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non- abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary. DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced. Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov. These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s purposes, this matter should be referred to Acuity Brands Lighting, Inc. a parent company of Peerless Lighting. ü Disconnect or turn off power before installation or servicing. ü Verify that supply voltage is correct by comparing it with the luminaire label information. ü Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements. ü WARNING RISK OF ELECTRIC SHOCK All wiring connections should be capped with UL approved recognized wire connectors. ü To prevent luminaire row from over- current: By adding the input current of each luminaire section marked on the luminaire, the total current per power feed must not exceed the maximum line wire amperage marked on the luminaire and the power feed cord/wire amperage rating whichever the least. WARNING RISK OF BURN ü Allow lamp/luminaire to cool before handling. Do not touch enclosure or light source. ü Do not exceed maximum wattage marked on luminaire label. ü Follow all manufacturer s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling. Part Number: PIN004102 Description: INSTR, IMPORTANT SAFETY LED Revision: C Effective Date: 07/2012 ECO3665 page 1 of 2

General Installation Instructions LED CAUTION RISK OF INJURY ü Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance. ü Avoid direct eye exposure to the light source while it is on. CAUTION RISK OF FIRE ü Keep combustible and other materials that can burn away from lamp/lens. ü Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying. CAUTION RISK OF PRODUCT DAMAGE ü Never connect components under load. ü Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation. ü Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED luminaires must be powered directly off a switched circuit. ü Unless individual product specifications deem otherwise: Do not restrict luminaire ventilation. Allow for some volume of airspace around luminaire. Avoid covering LED luminaires with insulation, foam or other material that will prevent convection or conduction cooling. ü Unless individual product specifications deem otherwise: Do not exceed luminaire s maximum ambient temperature. ü Only use luminaire in its intended location. ü LED products are polarity sensitive. Ensure proper polarity before installation. ü Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit. ü Do not touch individual electrical components as this can cause ESD, shorten lamp life or alter performance. ü Some components inside the luminaire may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact a Peerless Lighting representative for assistance. ü Always read the fixtures complete installation instructions prior to installation for any additional luminaire specific warnings. Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements. Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.peerlesslighting.com. Peerless Lighting, an Acuity Brands Company, assumes no responsibility for claims arising out of improper or careless installation or handling of its products. Part Number: PIN004102 Description: INSTR, IMPORTANT SAFETY LED Revision: C Effective Date: 07/2012 ECO3665 Page 2 of 2

Peerless Mino 1x1 Recessed INSTALLATION INSTRUCTIONS PIN006200 Rev. A 05/07/13 ECO3672 These installation instructions are used for installing the following luminaires and kits: Luminaire 1x1 G or ST Mounting Kit G/ST/FLNGW/RW WARNING: Please read the important safety instructions prior to installation of this product. A) Identification of 1x1 G or ST Luminaire.... Page 1 B) 1x1 Recessed Installation (into 2x2 or 2x4 Grid Ceiling) Page 2 C) Drywall Grid Adapter Option (FLNGW)...Page 3 D) Recessed Wall Option (RW).....Page 4 A) Identification of 1x1 Luminaire Luminaire Components Conduit (by others) Support wires Ceiling tile (by others) Bottom view Side view 1

PIN006200 Rev. A 05/07/13 ECO3672 B) 1x1 Recessed Installation (into 2x2 or 2x4 Grid Ceiling) 1 2 3 #8 screws (2x) 2x2 or 2x4 Ceiling tile PIN000000 Rev. X 00/00/00 ECO0000 2x2 or 2x4 Ceiling tile XXX #8 screws (2x) Flange 14.5 x14.5 Unscrew #8 screws (4x) and remove flange from luminaire. Cut 14.5 x14.5 square opening inside a 2x2 or 2x4 ceiling tile. Drop the ceiling tile on flange kit and attach flange to luminaire by #8 screws (4x). 4 5 6 #8 screws (2x) Luminaire height adjustment Ceiling grid Make sure flange is secured by #8 screws (4x). Install luminaire into ceiling resting it on four screws. Adjust screws vertically to rest on grid and tighten the nuts (4x). Make sure ceiling is leveled and there is no gap between ceiling tile and grid. Access plate 7 8 9 Ground screw Support wire Unscrew #8 screws (2x) and remove access plate. Run power cord from junction box to fixture, knocking out one hole in access plate to pass cord through. Perform wire splices and insert wires back into the luminaire. Secure access plate. Use ground screw on access plate to ground luminaire. Secure luminaire with support wires if needed. Peel away lens cover after luminaire is fully installed. 2

PIN006200 Rev. A 05/07/13 ECO3672 C) Drywall Grid Adapter Option (FLNGW) for Sheet Rock Ceilings (5/8 Thick) Minimum Ceiling Clearance = 10 L Bracket 1 (4x) PIN000000 2 Rev. X 00/00/00 Holes for ECO0000 3 Drywall screws guide wires to structure XXX Sheet rock ceiling CONTRACTOR TO SPAKLE, FEATHER AND SAND TRIM Guide wires to structure (4x) (by others) #6 screws (4x) Drywall grid adapter kit comes assembled with #6 screws (4x) and L brackets (4x) as illustrated above. APPROX. ½ Fasten sheet rock into aluminum extrusion frame using drywall screws. Drywall grid adapter is designed for 5/8 sheetrock, so allow approximately 1/16 for mudding and blending to finish ceiling. Make sure that the frame is square and tight against the ceiling. Ensure guide wires to structure (by others) are properly secured. 4 5 6 Luminaire rests SECURELY on four sides Remove access plate. Run power cord from junction box to luminaire, knocking out one hole in access plate to pass cord through. Perform wire splices and insert wires back into the luminaire. Use ground screw on access plate to ground luminaire. Replace access plate. Insert luminaire into ceiling through the drywall kit. Ensure the luminaire rests securely on drywall kit with brackets on all four sides. 7 Peel away the lens cover after luminaire is fully installed. 3

PIN006200 Rev. A 05/07/13 ECO3672 D) Recessed Wall Option (RW) 1 2 3 PIN000000 Rev. X 00/00/00 ECO0000 XXX 14.875 x14.875 Using a key hole saw or equivalent and cut 14.875 x14.875 square opening in drywall. Insert the sheet metal frame in drywall as shown in illustration and drive #8 drywall screws (8x) into the joists covered by the sheet rock. Give each nail an extra hammer tap to make sure the frame is secured. Drywall taping knife Use a 5 -wide drywall taping knife or equivalent to spread joint compound onto the drywall screws. Smooth the compound until the flange of frame and screws are even with the rest of the surface. Apply primer and finish coat as needed. 4 5 6 Remove access plate. Run power cord from junction box to luminaire, knocking out one hole in access plate to pass cord through. Perform wire splices and insert wires back into the luminaire. Use ground screw on access plate to ground luminaire. Replace access plate. To finish luminaire installation mount the luminaire to sheet frame using #6 screws (4x) as illustrated above. Peel away lens cover after luminaire is fully installed. E) Lens Care Instructions Once installed, if the Peerless Mino lens needs to be removed for any reason, wear cotton gloves to protect against fingerprints. Clean lenses with soft cloth. Dampen cloth with water if needed. When reaffixing the lens, push the lens up from the center so that it is flat against the housing before retightening the thumbscrews. 4