minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)

Similar documents
minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

DIGITAL PANEL INSTRUMENTS

installation depth: 90 mm without plug-in terminal 30 additional adjustable setpoints permanent MIN/MAX-value recording volume measuring (totaliser)

minimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

minimal installation depth: 97 mm without plug-in terminal min-/max-value recording display flashing at threshold undercut/ exceedance

installation depth: 90 mm without plug-in terminal display flashing at threshold exceedance / threshold undershooting

m/min Digital panel meter with 4½-digit PV4, PT4, PF4, PW4 galvanically insulated 8 free scalable setpoints/hysteresis optical setpoint indication

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply

72x36. Digital panel meter with microprocessor based technology 4-digit PVE4, PTE4, PFE4, PFL4. Galvanically insulated

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

48x48. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output

Digital panelmeter with microprocessor based technology 5 digit. 4 free scalable setpoints/hysteresis/delay time (option)

Process displays For standard signals, temperature, resistance measurement

DIGITAL PANEL INSTRUMENTS

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Assembly. Front view. Parametrization interface. Power Bus

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

CONTA-ELECTRONICS. Converter Units

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature head transmitter itemp PCP TMT 181

DP2000 ORDERING GUIDE To Order MODEL NO.

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

Analogue temperature controllers

Q.raxx A slimline RS / EC

DIGITAL PANEL METER N24 AND N25 METER SERIES

SINEAX V 604s Programmable multifunctional transmitter

Temperature Transmitters - Head Mounted

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

Measurement and Instrumentation

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Q.raxx A101-8 slimline RS / EC

CAN-IO Custom IO remote module

DRG-SC Series Signal Conditioners

Q.raxx A slimline RS / EC Universal Measurement System

P5201 Universal Programmable Transmitters with Galvanic Isolation

08/07/2015

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

S200 I/O System Units

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Digital indicator for panel mounting With multi-function input Model DI25

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

DIGEM f 96 x 48 EK. Applications. Description

N24, N25 DIGITAL PANEL METER

Rotational speed controller

08/07/2015

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

High Performance Process & Temperature Controllers

02/11/2015

Excellent low-cost Process & Temperature Controllers

APPENDIX APPENDIX A 1

MCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. LCD Display.

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

05/09/2012

User manual for PZ5 devices

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

JUMO di 32 / di 08. Brief description. Block structure

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

VariTrans P V. Safe and Sound.

itemp HART DIN rail TMT112

Insulation Guard IW 1000 Monitoring of ungrounded AC- and DC voltage systems up to 690V

DATA SHEET Selectable AC transducer TAS-311DG

Thermocouple - Transducer

Temperature Transmitters - DIN Rail Mounted

Isolators A3/1.

DIGITAL PANEL METERS. Overview of product range. Product selection guide. Info & advice. µdigi1 and µdigi2 ranges

SDM3045X Digital Multimeter. DataSheet

Temperature head transmitter itemp PCP TMT 181

02/11/2015

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

B850 Boiler House Energy Monitor

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

Technical Information itemp TMT180

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

Indicators and configurable displays

SINEAX TV809, 1 channel Programmable Isolating Amplifier

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Economical Digital Indicators For Process and Electrical Measurement

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

Custom "Compact" range with display CD20 Custom Part number

M70LL Laser Distance Sensor

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Measurement and control. Digital instruments and measuring transducers

MODEL: KS. Plug-in Signal Conditioners K-UNIT

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

USB-2404-UI Specifications

7SD/7SH/7SM Temperature Controllers

SHIMADEN DIGITAL INDICATORS

Transcription:

Digital panel meter 5-digit M2 red display of -19999 99999 digits (optional green, orange, blue or tricolour display) minimal installation depth: 70 mm without plug-in terminal adjustment via factory default or directly on the sensor signal min-/max-memory 30 additional adjustable setpoints (parameter driven) display flashing at threshold exceedance / undercut zero key for actuation of tara- /hold-function permanent min-/max-value recording volume measurement (totaliser) mathematical functions like reciprocal value, square root, square and rounding programming interlock via access code protection class IP65 at the front plug-in terminal two relay outputs optional optional analog output or sensor supply optional galv. insulated digital input accessories: pc-based configuration-kit PM-TOOL with CD & USB adapter for devices without keypad, for a simple adjustment of standard devices on demand: devices for working temperatures of -40 80 C or -25 C 60 C Status 11/05/12 - panelmeter96x48analog_gb.doc page 23 96x48

Digital panel meter Direct current Direct voltage Shunt Potentiometer Resistance Pt100 Thermocouple Frequency AC-RMS DMS-4-wire Weighing technology ORDER NUMBER Direct current, direct voltage Supply 230 VAC M2-1VR5B.0001.570BD 160,00 Supply 10-30 VDC M2-1VR5B.0001.670BD 190,00 M 2-1 V R 5 B. 0 0 0 1. 5 7 0 B D M 2-1 V R 5 B. 0 0 0 1. 6 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 2 Sensor supply 10 VDC / 20 ma incl. digital input with 230 VAC 25,00 Sensor supply 10 VDC / 20 ma incl. digital input with 10-30 VDC 55,00 3 Sensor supply 24 VDC / 50 ma incl. digital input with 230 VAC 25,00 Sensor supply 24 VDC / 50 ma incl. digital input with 10-30 VDC 55,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs, analog output or sensor supply. Status 11/05/12 - panelmeter96x48analog_gb.doc page 24

Direct current, direct voltage Special measuring inputs H Supply 230 VAC M2-1VR5B.0H01.570BD 220,00 Special measuring input 600 V, 300 V, 50 V, 1 A M 2-1 V R 5 B. 0 H 0 1. 5 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC 90,00 I Digital input galv. insulated 10,00 *Only one option possible: relay outputs, analog output or sensor supply. Status 11/05/12 - panelmeter96x48analog_gb.doc page 25 96x48

Direct voltage (Shunt) Supply 230 VAC M2-1VR5B.0002.570BD 190,00 Supply 10-30 VDC M2-1VR5B.0002.670BD 225,00 M 2-1 V R 5 B. 0 0 0 2. 5 7 0 B D M 2-1 V R 5 B. 0 0 0 2. 6 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 26

Potentiometer 0-100 % (>1 kω <1000 kω) Supply 230 VAC M2-1VR5B.0005.570BD 188,00 Supply 10-30 VDC M2-1VR5B.0005.670BD 218,00 M 2-1 V R 5 B. 0 0 0 5. 5 M 2-1 V R 5 B. 0 0 0 5. 6 7 0 B D 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 27 96x48

Resistance (1 kω, 10 kω or 100 kω) Supply 230 VAC M2-1VR5B.0006.570BD 188,00 Supply 10-30 VDC M2-1VR5B.0006.670BD 225,00 M 2-1 V R 5 B. 0 0 0 6. 5 7 0 B D M 2-1 V R 5 B. 0 0 0 6. 6 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 28

Pt100 (4-wire) -200,0 C 850,0 C / -328,0 F 1562,0 F Supply 230 VAC M2-1TR5B.010C.570BD 200,00 Supply 10-30 VDC M2-1TR5B.010C.670BD 230,00 Supply 230 VAC M2-1TR5B.020C.570BD 175,00 Supply 10-30 VDC M2-1TR5B.020C.670BD 210,00 Special measuring input: Pt100-2-wire M 2-1 T R 5 B. 0 X 0 C. 5 7 0 B D M 2-1 T R 5 B. 0 X 0 C. 6 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 29 96x48

Thermocouple type L, J, K, B, S, N, E, T, R Supply 230 VAC M2-1TR5B.040X.570BD 195,00 Supply 10-30 VDC M2-1TR5B.040X.670BD 230,00 M 2-1 T R 5 B. 0 4 0 X. 5 7 0 B D M 2-1 T R 5 B. 0 4 0 X. 6 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 30

Frequency (0.01 Hz to 999.99 khz) Supply 230 VDC M2-1FR5B.0307.570BD 185,00 Frequency (0.01 Hz to 999.99 khz) for incremental encoder S420 Advice: Using Namur sensors with a nominal voltage of approx. 8 V, a sensor supply of 12 VDC needs to be provided. M 2-1 F R 5 B. 0 3 0 7. 5 7 0 B D S420 Pulse inputs for incremental encoders 40,00 X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 6 Sensor supply 12 VDC / 50 ma incl. digital input 15,35 K Impuls output max. 10 khz 10,00 *For devices with a 230 VAC voltage supply, no relay outputs are available. Status 11/05/12 - panelmeter96x48analog_gb.doc page 31 96x48

Frequency (0.01 Hz to 999.99 khz) Supply 10-30 VDC M2-1FR5B.0007.670BD 195,00 Frequency (0.01 Hz to 999.99 khz) for incremental encoder S420 Advice: Using Namur sensors with a nominal voltage of approx. 8 V, a sensor supply of 12 VDC needs to be provided. M 2-1 F R 5 B. 0 0 0 7. 6 7 0 B D S420 Pulse inputs for incremental encoders 40,00 X Analog output 0/4-20 ma, 0-10 VDC 90,00 2 Sensor supply 10 VDC / 20 ma incl. digital input 55,00 3 Sensor supply 24 VDC / 50 ma incl. digital input 55,00 6 Sensor supply 12 VDC / 50 ma incl. digital input 55,00 K Pulse output max. 10 khz, incl senor supply 24 VDC 65,00 / incl. digital input *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs, analog output or sensor supply. Status 11/05/12 - panelmeter96x48analog_gb.doc page 32

AC voltage, alternating current (true RMS) Supply 230 VAC M2-1VR5B.0004.570BD 240,00 Supply 10-30 VDC M2-1VR5B.0004.670BD 270,00 M 2-1 V R 5 B. 0 0 0 4. 5 M 2-1 V R 5 B. 0 0 0 4. 6 7 0 B D 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 33 96x48

AC voltage, alternating current (true RMS) special measuring inputs H Supply 230 VAC M2-1VR5B.0H04.570BD 260,00 Special measuring input: 600 V, 300 V, 1 A, 5 AAC M 2-1 V R 5 B. 0 H 0 4. 5 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC 90,00 I Digital input galv. insulated 10,00 *Only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 34

DMS-4-wire with calibration Supply 230 VAC M2-1MR5B.020X.570BD 245,00 Supply 10-30 VDC M2-1MR5B.020X.670BD 310,00 M 2-1 M R 5 B. 0 2 0 X. 5 M 2-1 M R 5 B. 0 2 0 X. 6 7 0 B D 7 0 B D *For devices with a 230 VAC voltage supply, relay outputs are not available. Status 11/05/12 - panelmeter96x48analog_gb.doc page 35 96x48

Weighing technology Supply 230 VAC M2-1WR5B.020X.570BD 245,00 Supply 10-30 VDC M2-1WR5B.020X.670BD 310,00 M 2-1 W R 5 B. 0 2 0 X. 5 7 0 M 2-1 W R 5 B. 0 2 0 X. 6 7 0 B D B D *For devices with a 230 VAC voltage supply, relay outputs are not available. Accessories PC based configuration software PM-Tool for devices without keypad, PM-TOOL-MUSB4 89,00 for a simple adjustment of standard devices, incl. CD & USB-adapter. Programming is made via an interface on the back. Status 11/05/12 - panelmeter96x48analog_gb.doc page 36

Connection examples - M2 devices with a direct current /direct voltage input and sensor supply. M2-devices with frequency input / impulse input Status 11/05/12 - panelmeter96x48analog_gb.doc page 37 96x48

Technical data Dimension Housing B96 x H48 x D70 mm (including plug-in terminal D= 89 mm) Panel cut-out 92.0 +0.8 x 45.0 +0.6 mm Fixing screw elements for insulation thickness up to 3 mm Housing material PC Polycarbonate, black Sealing material EPDM, 65 Shore, black Protection class at the front IP65 standard, back side IP00 Weight approx. 200 g Connection plug-in terminal; line cross-section up to 2.5 mm 2 Display Display 5-digit Digit height 14 mm Segment colour red (standard), optional available in green, blue, orange and tricolour Display range -19999 to 99999 Setpoints optical display flashing Overflow horizontal bars at the top Underflow horizontal bars at the bottom Display time 0.1 to 10.0 seconds Measuring input M2-1VR5B.0001 Span -12 12 V / -22 24 ma Direct current / Measuring range 0-10 V / 0/4-20 ma Direct voltage Input resistance Ri at ~200 kω / Ri at ~100 Ω Measuring fault 0.1% of measuring range, ± 1 Digit / 0.1% of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1 second measuring time Measuring input M2-1VR5B.0H01 Span 0 600 VDC / 0 300 VDC / 0 50 VDC / 0 1 ADC H Direct current / Input resistance Ri at ~ 2 MΩ / Ri at ~ 1 MΩ / Ri at ~200 kω / Ri at ~0,2 Ω Direct voltage Measuring fault 0.5 % of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1s measuring time Measuring input M2-1VR5B.0002 Span -5 75 mv / -15 180 mv / -30 360 mv / -100 1200 mv Shunt Measuring range 0 60 mv / 0 150 mv / 0 300 mv / 0 1000 mv Input resistance Ri at ~12 kω / Ri at ~60 Ω / Ri at ~30 Ω / Ri at ~200 Ω Measuring fault 0.2% of measuring range, ± 1 Digit / 0.2% of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1s measuring time Measuring input M2-1VR5B.0005 Span >1 kω <1000 kω Potentiometer Measuring range 0 100 % Measuring fault 0.2% of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1s measuring time Measuring input M2-1VR5B.0x06 Span 0 1.1 kω / 0 11 kω / 0 110 kω Resistance Measuring range 0 1 kω / 0 10 kω / 0 100 kω Measuring fault 0.5% of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1s measuring time Measuring input M2-1TR5B.030C Span -200,0 850,0 C / -328,0 1562,0 F Pt100 Measuring fault 0.1% of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution 0.1 C or 0.1 F Status 11/05/12 - panelmeter96x48analog_gb.doc page 38

Measuring input M2-1TR5B.040C Measuring range Type L -200 900 C Thermocouple Type J -210 1200 C Type K -270 1372 C Type B 80 1820 C Type S -50 1768 C Type N -270 1300 C Type E -270 1000 C Type T -270 400 C Type R -50 1768 C Measuring fault 2 K, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution 0.1 C Characteristic curve fault <± 1 K Reference junction thermistor Measuring input M2-1FR5B.0007 Signal impulse input, TTL, Namur, 3-wire initiator PNP/NPN Frequency Input resistance Ri at 24 V / 4 kω High/Low level >15 V / < 4 V High/Low TTL level >4.6 V / <1.9 V Input frequency 0.01 Hz selectable up to 999.99 khz Measuring fault 0.05% of measuring range, ± 1 digit Measuring input M2-1VR5B.0004 Measuring range 50 VAC / 10 VAC / 5 AAC / 1 AAC AC voltage Input resistance Ri at ~200 kω / Ri at ~40 kω / Ri at ~0.05 Ω / Ri at ~200 Ω Measuring fault 0.5% of measuring range at 50 Hz.1 khz up to crestfactor 4 for input signals of 1 100% of final value Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1 second measuring time Measuring input M2-1VR5B.0H04 Measuring range 600 VAC / 300 VAC / 5 AAC / 1 AAC H AC voltage Input resistance Ri at ~2 MΩ / Ri at ~1 MΩ / Ri at ~0.05 Ω / Ri at ~200 Ω Measuring fault 0.5% of measuring range at 50 Hz.1 khz up to crestfactor 4 for input signals of 1 100% of final value Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1 second measuring time Measuring input M2-1MR5B.020X Sensor sensitivity 1 mv/v, 2 mv/v, 3.3 mv/v M2-1WR5B.020X Output Relay Switching cycle Impulse output Analog output Sensor supply Bridge supply with change-over contact 250 V / 2 AAC, 30 V / 2 ADC 0.5 * 10 5 at max. contact load 5 * 10 6 mechanically Separation in accordance with DIN EN 50178 / Specifications in accordance with DIN EN 60255 max. 10 khz (only for frequency metering devices) 0-10 VDC, 0/4-20 ma (16 Bit) switchable 24 VDC / 50 ma 10 VDC / 20 ma 10 VDC / 20-40 ma / 250-500 Ω Digital input Input galv. insulated < 2.4 OFF; > 10 V ON; max. 30 VDC Ri at ~ 5 kω Power pack Memory Supply EEPROM Data life 230 VAC +/- 10 % (max. 10 VA) 10-30 VDC, galvanic insulated (max. 4 VA) 100 years Ambient conditions Working temperature 0 to + 60 C Storing temperature -20 to + 80 C Climatic density relative humidity 0-85% on years average without dew Status 11/05/12 - panelmeter96x48analog_gb.doc page 39 96x48

Sealing CE-sign Conformity to directive 2004/108/EG EMV EN 61326 Safety standard according to low voltage directive 2006/95/EG EN 61010; EN 60664-1 Housing: 3,0 M2 48,0 Gap for physical dimension 89,0 Installation depth incl. connection terminal Status 11/05/12 - panelmeter96x48analog_gb.doc page 40

Ordering code M2 - Digital display standard M 2-1 V R 5 B. 0 0 0 1. 6 7 0 B D Basic type M-Line Dimension D physical unit Installation depth 89 mm 2 Version (incl. plug-in terminal) B B Housing size Setpoints 96x48x70 mm (BxHxD) 1 0 no setpoints Display type 2 2 relay outputs DMS M Protection class Frequency F 1 without keypad, operation on the back Temperature T 7 IP65 / plug-in terminal V, A, Ohm V Weighing technology W Supply voltage 4 115 VAC plus 10,25 Display colours 5 230 VAC Blue B 6 10-30 VDC galv. insulated Green G Red R Measuring input Red/Green/Orange T 1 Direct current, direct voltage Orange Y 2 Shunt 4 AC, true RMS Number of digits 5 Potentiometer 5-digit 5 6 Resistance 7 Frequency Digit height C Pt100 up to 800 C 14 mm B X Thermocouple type B,E,J,K,L,N,R,S,T Digital input X DMS/Weighing technology 1 3.3mV without 0 1x, incl. sensor supply I Analog output 0 without DC devices X 0-10 VDC, 0/4-20 ma 100 VDC, 600 VDC, H 200 ma,1 ADC Sensor supply AC devices 0 without 300 VAC, 600 VAC H 2 10 VD / 20 ma 1 A, 5 AAC Incl. digital input Temperature devices 3 24 VDC / 50 ma Pt100-4-wire 1 Incl. digital input Pt100-2-wire 2 6 12 VDC / 50 ma Thermocouple 4 Incl. digital input Resistance 1 MΩ 7 K 24 VDC / 50 ma (only for frequency metering devices) Incl. digital input and impulse output (10 khz only for frequency metering devices) Status 11/05/12 - panelmeter96x48analog_gb.doc page 41

Blind covers with fastening clamps GH009-06 9,00 Status 11/05/12 - panelmeter96x48analog_gb.doc page 42