Digital panel meter 5-digit M2 red display of -19999 99999 digits (optional green, orange, blue or tricolour display) minimal installation depth: 70 mm without plug-in terminal adjustment via factory default or directly on the sensor signal min-/max-memory 30 additional adjustable setpoints (parameter driven) display flashing at threshold exceedance / undercut zero key for actuation of tara- /hold-function permanent min-/max-value recording volume measurement (totaliser) mathematical functions like reciprocal value, square root, square and rounding programming interlock via access code protection class IP65 at the front plug-in terminal two relay outputs optional optional analog output or sensor supply optional galv. insulated digital input accessories: pc-based configuration-kit PM-TOOL with CD & USB adapter for devices without keypad, for a simple adjustment of standard devices on demand: devices for working temperatures of -40 80 C or -25 C 60 C Status 11/05/12 - panelmeter96x48analog_gb.doc page 23 96x48
Digital panel meter Direct current Direct voltage Shunt Potentiometer Resistance Pt100 Thermocouple Frequency AC-RMS DMS-4-wire Weighing technology ORDER NUMBER Direct current, direct voltage Supply 230 VAC M2-1VR5B.0001.570BD 160,00 Supply 10-30 VDC M2-1VR5B.0001.670BD 190,00 M 2-1 V R 5 B. 0 0 0 1. 5 7 0 B D M 2-1 V R 5 B. 0 0 0 1. 6 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 2 Sensor supply 10 VDC / 20 ma incl. digital input with 230 VAC 25,00 Sensor supply 10 VDC / 20 ma incl. digital input with 10-30 VDC 55,00 3 Sensor supply 24 VDC / 50 ma incl. digital input with 230 VAC 25,00 Sensor supply 24 VDC / 50 ma incl. digital input with 10-30 VDC 55,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs, analog output or sensor supply. Status 11/05/12 - panelmeter96x48analog_gb.doc page 24
Direct current, direct voltage Special measuring inputs H Supply 230 VAC M2-1VR5B.0H01.570BD 220,00 Special measuring input 600 V, 300 V, 50 V, 1 A M 2-1 V R 5 B. 0 H 0 1. 5 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC 90,00 I Digital input galv. insulated 10,00 *Only one option possible: relay outputs, analog output or sensor supply. Status 11/05/12 - panelmeter96x48analog_gb.doc page 25 96x48
Direct voltage (Shunt) Supply 230 VAC M2-1VR5B.0002.570BD 190,00 Supply 10-30 VDC M2-1VR5B.0002.670BD 225,00 M 2-1 V R 5 B. 0 0 0 2. 5 7 0 B D M 2-1 V R 5 B. 0 0 0 2. 6 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 26
Potentiometer 0-100 % (>1 kω <1000 kω) Supply 230 VAC M2-1VR5B.0005.570BD 188,00 Supply 10-30 VDC M2-1VR5B.0005.670BD 218,00 M 2-1 V R 5 B. 0 0 0 5. 5 M 2-1 V R 5 B. 0 0 0 5. 6 7 0 B D 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 27 96x48
Resistance (1 kω, 10 kω or 100 kω) Supply 230 VAC M2-1VR5B.0006.570BD 188,00 Supply 10-30 VDC M2-1VR5B.0006.670BD 225,00 M 2-1 V R 5 B. 0 0 0 6. 5 7 0 B D M 2-1 V R 5 B. 0 0 0 6. 6 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 28
Pt100 (4-wire) -200,0 C 850,0 C / -328,0 F 1562,0 F Supply 230 VAC M2-1TR5B.010C.570BD 200,00 Supply 10-30 VDC M2-1TR5B.010C.670BD 230,00 Supply 230 VAC M2-1TR5B.020C.570BD 175,00 Supply 10-30 VDC M2-1TR5B.020C.670BD 210,00 Special measuring input: Pt100-2-wire M 2-1 T R 5 B. 0 X 0 C. 5 7 0 B D M 2-1 T R 5 B. 0 X 0 C. 6 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 29 96x48
Thermocouple type L, J, K, B, S, N, E, T, R Supply 230 VAC M2-1TR5B.040X.570BD 195,00 Supply 10-30 VDC M2-1TR5B.040X.670BD 230,00 M 2-1 T R 5 B. 0 4 0 X. 5 7 0 B D M 2-1 T R 5 B. 0 4 0 X. 6 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 30
Frequency (0.01 Hz to 999.99 khz) Supply 230 VDC M2-1FR5B.0307.570BD 185,00 Frequency (0.01 Hz to 999.99 khz) for incremental encoder S420 Advice: Using Namur sensors with a nominal voltage of approx. 8 V, a sensor supply of 12 VDC needs to be provided. M 2-1 F R 5 B. 0 3 0 7. 5 7 0 B D S420 Pulse inputs for incremental encoders 40,00 X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 6 Sensor supply 12 VDC / 50 ma incl. digital input 15,35 K Impuls output max. 10 khz 10,00 *For devices with a 230 VAC voltage supply, no relay outputs are available. Status 11/05/12 - panelmeter96x48analog_gb.doc page 31 96x48
Frequency (0.01 Hz to 999.99 khz) Supply 10-30 VDC M2-1FR5B.0007.670BD 195,00 Frequency (0.01 Hz to 999.99 khz) for incremental encoder S420 Advice: Using Namur sensors with a nominal voltage of approx. 8 V, a sensor supply of 12 VDC needs to be provided. M 2-1 F R 5 B. 0 0 0 7. 6 7 0 B D S420 Pulse inputs for incremental encoders 40,00 X Analog output 0/4-20 ma, 0-10 VDC 90,00 2 Sensor supply 10 VDC / 20 ma incl. digital input 55,00 3 Sensor supply 24 VDC / 50 ma incl. digital input 55,00 6 Sensor supply 12 VDC / 50 ma incl. digital input 55,00 K Pulse output max. 10 khz, incl senor supply 24 VDC 65,00 / incl. digital input *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs, analog output or sensor supply. Status 11/05/12 - panelmeter96x48analog_gb.doc page 32
AC voltage, alternating current (true RMS) Supply 230 VAC M2-1VR5B.0004.570BD 240,00 Supply 10-30 VDC M2-1VR5B.0004.670BD 270,00 M 2-1 V R 5 B. 0 0 0 4. 5 M 2-1 V R 5 B. 0 0 0 4. 6 7 0 B D 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC with 230 VAC 90,00 Analog output 0/4-20 ma, 0-10 VDC with 10-30 VDC 120,00 I Digital input galv. insulated 10,00 *For devices with a 230 VAC voltage supply, there is only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 33 96x48
AC voltage, alternating current (true RMS) special measuring inputs H Supply 230 VAC M2-1VR5B.0H04.570BD 260,00 Special measuring input: 600 V, 300 V, 1 A, 5 AAC M 2-1 V R 5 B. 0 H 0 4. 5 7 0 B D X Analog output 0/4-20 ma, 0-10 VDC 90,00 I Digital input galv. insulated 10,00 *Only one option possible: relay outputs or analog output. Status 11/05/12 - panelmeter96x48analog_gb.doc page 34
DMS-4-wire with calibration Supply 230 VAC M2-1MR5B.020X.570BD 245,00 Supply 10-30 VDC M2-1MR5B.020X.670BD 310,00 M 2-1 M R 5 B. 0 2 0 X. 5 M 2-1 M R 5 B. 0 2 0 X. 6 7 0 B D 7 0 B D *For devices with a 230 VAC voltage supply, relay outputs are not available. Status 11/05/12 - panelmeter96x48analog_gb.doc page 35 96x48
Weighing technology Supply 230 VAC M2-1WR5B.020X.570BD 245,00 Supply 10-30 VDC M2-1WR5B.020X.670BD 310,00 M 2-1 W R 5 B. 0 2 0 X. 5 7 0 M 2-1 W R 5 B. 0 2 0 X. 6 7 0 B D B D *For devices with a 230 VAC voltage supply, relay outputs are not available. Accessories PC based configuration software PM-Tool for devices without keypad, PM-TOOL-MUSB4 89,00 for a simple adjustment of standard devices, incl. CD & USB-adapter. Programming is made via an interface on the back. Status 11/05/12 - panelmeter96x48analog_gb.doc page 36
Connection examples - M2 devices with a direct current /direct voltage input and sensor supply. M2-devices with frequency input / impulse input Status 11/05/12 - panelmeter96x48analog_gb.doc page 37 96x48
Technical data Dimension Housing B96 x H48 x D70 mm (including plug-in terminal D= 89 mm) Panel cut-out 92.0 +0.8 x 45.0 +0.6 mm Fixing screw elements for insulation thickness up to 3 mm Housing material PC Polycarbonate, black Sealing material EPDM, 65 Shore, black Protection class at the front IP65 standard, back side IP00 Weight approx. 200 g Connection plug-in terminal; line cross-section up to 2.5 mm 2 Display Display 5-digit Digit height 14 mm Segment colour red (standard), optional available in green, blue, orange and tricolour Display range -19999 to 99999 Setpoints optical display flashing Overflow horizontal bars at the top Underflow horizontal bars at the bottom Display time 0.1 to 10.0 seconds Measuring input M2-1VR5B.0001 Span -12 12 V / -22 24 ma Direct current / Measuring range 0-10 V / 0/4-20 ma Direct voltage Input resistance Ri at ~200 kω / Ri at ~100 Ω Measuring fault 0.1% of measuring range, ± 1 Digit / 0.1% of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1 second measuring time Measuring input M2-1VR5B.0H01 Span 0 600 VDC / 0 300 VDC / 0 50 VDC / 0 1 ADC H Direct current / Input resistance Ri at ~ 2 MΩ / Ri at ~ 1 MΩ / Ri at ~200 kω / Ri at ~0,2 Ω Direct voltage Measuring fault 0.5 % of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1s measuring time Measuring input M2-1VR5B.0002 Span -5 75 mv / -15 180 mv / -30 360 mv / -100 1200 mv Shunt Measuring range 0 60 mv / 0 150 mv / 0 300 mv / 0 1000 mv Input resistance Ri at ~12 kω / Ri at ~60 Ω / Ri at ~30 Ω / Ri at ~200 Ω Measuring fault 0.2% of measuring range, ± 1 Digit / 0.2% of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1s measuring time Measuring input M2-1VR5B.0005 Span >1 kω <1000 kω Potentiometer Measuring range 0 100 % Measuring fault 0.2% of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1s measuring time Measuring input M2-1VR5B.0x06 Span 0 1.1 kω / 0 11 kω / 0 110 kω Resistance Measuring range 0 1 kω / 0 10 kω / 0 100 kω Measuring fault 0.5% of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1s measuring time Measuring input M2-1TR5B.030C Span -200,0 850,0 C / -328,0 1562,0 F Pt100 Measuring fault 0.1% of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution 0.1 C or 0.1 F Status 11/05/12 - panelmeter96x48analog_gb.doc page 38
Measuring input M2-1TR5B.040C Measuring range Type L -200 900 C Thermocouple Type J -210 1200 C Type K -270 1372 C Type B 80 1820 C Type S -50 1768 C Type N -270 1300 C Type E -270 1000 C Type T -270 400 C Type R -50 1768 C Measuring fault 2 K, ± 1 Digit Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution 0.1 C Characteristic curve fault <± 1 K Reference junction thermistor Measuring input M2-1FR5B.0007 Signal impulse input, TTL, Namur, 3-wire initiator PNP/NPN Frequency Input resistance Ri at 24 V / 4 kω High/Low level >15 V / < 4 V High/Low TTL level >4.6 V / <1.9 V Input frequency 0.01 Hz selectable up to 999.99 khz Measuring fault 0.05% of measuring range, ± 1 digit Measuring input M2-1VR5B.0004 Measuring range 50 VAC / 10 VAC / 5 AAC / 1 AAC AC voltage Input resistance Ri at ~200 kω / Ri at ~40 kω / Ri at ~0.05 Ω / Ri at ~200 Ω Measuring fault 0.5% of measuring range at 50 Hz.1 khz up to crestfactor 4 for input signals of 1 100% of final value Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1 second measuring time Measuring input M2-1VR5B.0H04 Measuring range 600 VAC / 300 VAC / 5 AAC / 1 AAC H AC voltage Input resistance Ri at ~2 MΩ / Ri at ~1 MΩ / Ri at ~0.05 Ω / Ri at ~200 Ω Measuring fault 0.5% of measuring range at 50 Hz.1 khz up to crestfactor 4 for input signals of 1 100% of final value Temperature drift 100 ppm/k Measuring time 0.1 10.0 seconds Measuring principle U/F-conversion Resolution approx. 18 Bit at 1 second measuring time Measuring input M2-1MR5B.020X Sensor sensitivity 1 mv/v, 2 mv/v, 3.3 mv/v M2-1WR5B.020X Output Relay Switching cycle Impulse output Analog output Sensor supply Bridge supply with change-over contact 250 V / 2 AAC, 30 V / 2 ADC 0.5 * 10 5 at max. contact load 5 * 10 6 mechanically Separation in accordance with DIN EN 50178 / Specifications in accordance with DIN EN 60255 max. 10 khz (only for frequency metering devices) 0-10 VDC, 0/4-20 ma (16 Bit) switchable 24 VDC / 50 ma 10 VDC / 20 ma 10 VDC / 20-40 ma / 250-500 Ω Digital input Input galv. insulated < 2.4 OFF; > 10 V ON; max. 30 VDC Ri at ~ 5 kω Power pack Memory Supply EEPROM Data life 230 VAC +/- 10 % (max. 10 VA) 10-30 VDC, galvanic insulated (max. 4 VA) 100 years Ambient conditions Working temperature 0 to + 60 C Storing temperature -20 to + 80 C Climatic density relative humidity 0-85% on years average without dew Status 11/05/12 - panelmeter96x48analog_gb.doc page 39 96x48
Sealing CE-sign Conformity to directive 2004/108/EG EMV EN 61326 Safety standard according to low voltage directive 2006/95/EG EN 61010; EN 60664-1 Housing: 3,0 M2 48,0 Gap for physical dimension 89,0 Installation depth incl. connection terminal Status 11/05/12 - panelmeter96x48analog_gb.doc page 40
Ordering code M2 - Digital display standard M 2-1 V R 5 B. 0 0 0 1. 6 7 0 B D Basic type M-Line Dimension D physical unit Installation depth 89 mm 2 Version (incl. plug-in terminal) B B Housing size Setpoints 96x48x70 mm (BxHxD) 1 0 no setpoints Display type 2 2 relay outputs DMS M Protection class Frequency F 1 without keypad, operation on the back Temperature T 7 IP65 / plug-in terminal V, A, Ohm V Weighing technology W Supply voltage 4 115 VAC plus 10,25 Display colours 5 230 VAC Blue B 6 10-30 VDC galv. insulated Green G Red R Measuring input Red/Green/Orange T 1 Direct current, direct voltage Orange Y 2 Shunt 4 AC, true RMS Number of digits 5 Potentiometer 5-digit 5 6 Resistance 7 Frequency Digit height C Pt100 up to 800 C 14 mm B X Thermocouple type B,E,J,K,L,N,R,S,T Digital input X DMS/Weighing technology 1 3.3mV without 0 1x, incl. sensor supply I Analog output 0 without DC devices X 0-10 VDC, 0/4-20 ma 100 VDC, 600 VDC, H 200 ma,1 ADC Sensor supply AC devices 0 without 300 VAC, 600 VAC H 2 10 VD / 20 ma 1 A, 5 AAC Incl. digital input Temperature devices 3 24 VDC / 50 ma Pt100-4-wire 1 Incl. digital input Pt100-2-wire 2 6 12 VDC / 50 ma Thermocouple 4 Incl. digital input Resistance 1 MΩ 7 K 24 VDC / 50 ma (only for frequency metering devices) Incl. digital input and impulse output (10 khz only for frequency metering devices) Status 11/05/12 - panelmeter96x48analog_gb.doc page 41
Blind covers with fastening clamps GH009-06 9,00 Status 11/05/12 - panelmeter96x48analog_gb.doc page 42