C u t l e r- H a m m e r. IQ Analyzer START Q U I C KS TA RT G U I D E

Similar documents
www. ElectricalPartManuals. com

Metering Devices, Protective Relays, Software and Connectivity

Operating Guide October 2006

TD17530E. Instructions for IQ Analyzer Electrical Distribution System Monitor

Data Sheet. RISH Master Record %THD

MultiCube Multi-Function Electricity Meter. Installation and Operation

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Installation and Operating Instructions

ULTRA RAPID POWER QUALITY ANALYZER

Digital Multifunction Instrument - Rish Master 3440

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Technical Data Sheet AMIK 300 / 301

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

IQ Analyzer 6400/6600 Series

Installation Instructions and Reference Handbook. Installation instructions

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL

Ziegler EM 1320/30/40

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems

PEM353. Universal measuring device

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

USER S MANUAL EMPOWER POWER METER TRINITY. Empower Operational Manual

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

ZHUHAI PILOT TECHNOLOGY CO., LTD.

PREMIER INSTALLATION AND OPERATING INSTRUCTIONS

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Multimeter 500CVD21 RTU500 series

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

ASCO 5210 Digital Power Meter. Operator s Manual DANGER

Operating Manual RISH EM 1320/30/ _Rev. C - 9/2014

ElNet VIP Current & Power Multimeter

VIP Current & Power Multimeter

Basic Energy Metering. TYPES OF METERS AND ITS Testing. Meter Tampering

Circuit Monitor Series 2000

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

Integra 1560 and 1580 Digital Transducer Systems

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

EPM Single-point submetering system. imagination at work. Engineered for retrofit and new construction with power line communication capability

RISH Master 3440i/3440iDL 0.2S

Mounting Instructions / Manual MV1171

PMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD.

See notes for calculations 4110 Usage Hours 1 Integer RO Y - Hours YP Usage Minutes 1 Integer RO Y - Minutes 0-59 YP

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

POWER MONITORING For Energy Management Systems

Delta Din-rail Power Meter DPM-D520I User Manual.

INTELLIMETER REGISTER

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

Installation & Operation Manual ELNet VIP

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

Portable Circuit Monitor Series 2000

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

4111 Usage Minutes 1 Integer RO Y - Minutes 0-59 Y Y YP

AMIK 200 / 201 Technical Data Sheet

PM 305 Operating Guide

Energy Management Three-phase energy meter with output modules Type EM4-DIN

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Technical Data Sheet

E50 MODBUS POINT MAP

PM130 PLUS Powermeter Series PM130P/PM130E/PM130EH

INTELLIMETER REGISTER

DIRIS A40/A41 RS485 PROFIBUS DP COM. Operating instructions. PROFIBUS Certification

Power Quality Recorders with Wireless Communications

Microprocessor Control Board Set Up Procedures (OR PLC)

MODEL 421 Over/Under Motor Load Monitor

SureTest Model ST-1THD & ST-1THDC Instructions

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Soluciones! Para el ahorro y control de la energía eléctrica. Distribuidor autorizado:

DIRIS A40/A41 RS485 PROFIBUS DP. Operating instructions F GB D I NL E P. SOCOMEC GROUP switching PROTECTION & ups

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

PM130 PLUS Powermeter Series PM130P/PM130E/PM130EH

mmint Modbus translator module installation and use

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT.

Technical Data Sheet. x1000. kwh R Y B

ELITE PRO. Automation Components, Inc.

Bulletin 1403 Ethernet Communications Card

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

56WM WirelessHART Power Meter SensEnable. Reference Manual Rev 4.0 December 2017

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

INSTRUCTION LEAFLET IL17553B IQ UNIVERSAL POWER SENTINEL TM INSTALLATION INSTRUCTIONS FOR THE IQ UNIVERSAL POWER SENTINEL TM INTERNAL CT

Series PM130 PLUS Powermeters PM130P/PM130E/PM130EH

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Installation Operation Programming

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

V Pg. M1: V, V, V Pg. M1 R1: Relay 1 Pg. M1 R2: Relay 2 (three-phase only) output status output status KW Pg. M2:,, Pg. M2n: neutral Pg. M3: P1, P2, P

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

HSIANG CHENG ELECTRIC CORP.

PLA 33. Power line analyzer. User and service manual. version 2.4

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts

Solectria Renewables Modbus Level 5 For models PVI KW

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

Transcription:

C u t l e r- H a m m e r IQ Analyzer START Q U I C KS TA RT G U I D E

C O N T E N T S Introduction 4 Mounting 9 IMPORTANT NOTICE Use this Guide to begin performing basic metering functions quickly, without reviewing complete instructions provided in the User s Manual. To more fully understand the wide array of features offered by your IQ Analyzer, it is strongly recommended that operators read the User s Manual. Following initial power-up of the IQ Analyzer, the displayed Meter Menu values may not be what is anticipated for your specific system. The unit must first be programmed with General Setup information relating to your electrical system. For additional information or technical assistance, contact: A D VANCED PRODUCT SUPPORT CENTER 1-800-809-2772 w w w. c u t l e r h a m m e r. e a t o n. c o m Wiring Programming Troubleshooting 10 12 19 3

ntroduction (USER S MANUAL SECTIONS 1&2) Operator Panel (USER S MANUAL SECTION 3) The IQ Analyzer is a compact, panel mounted, micro-processor based device for users who want to monitor all aspects of their electrical distribution system. It has been engineered to provide comprehensive metering, power quality analysis, remote input monitoring, control relaying, analog inputs/outputs and communications capabilities. It will replace dozens of existing individual meters, recorders, and relays. The IQ Analyzer displays a comprehensive list of metered parameters, historical values, harmonic profiles, peak demands and alarm data. Custom screens may be easily programmed to conveniently view parameter groupings, or to concurrently observe relationships as system conditions change. Information display options and device programming are accessible through a communications port via IMPACC ( I n t e g r a t e d Monitoring Protection and Control C o m m u n i c a t i o n s ), or directly at the Operator Panel using Meter Menu and Function Keys. (F1-F4) Previous Level Home Function PBs Meter Menu Program PB Help PB Function LEDs Display Window Up/Down PBs The IQ Analyzer directly monitors 3-phase lines to 600 Vac without the need for external potential transformers. Above 600 Vac, external transformers are required. The device complies with rigid ANSI C12.16 Class 10 revenue meter accuracy standards, and provides true rms readings through the 50th harmonic. Accuracy is maintained in applications with high distortion levels, including systems exhibiting 3.0 Crest F a c t o r. Push Buttons (PBs) (USER S MANUAL SECTIONS 3&4) Up/Down: Maneuver through metered values in Display Mode. Home: Return to Display Mode from other modes. Toggle between Current and Demand in Meter Menu. F1-F4: Used to enter analysis modes. Used to maneuver in program, analysis and reset m o d e s. Previous Level: Moves up one level in hierarchy (e.g., in Program mode from PGM/GEN/TYPE to PGM/GEN). R e s e t : Enter/Exit Reset mode. P r o g r a m : Enter/Exit Program mode. H e l p : Enter/Exit Help menu. 5

Modes of Operation Display Mode: (USER S MANUAL SECTIONS 5-2) T h e IQ Analyzer monitors and displays a comprehensive list of metered parameters. The Meter Menu provides easy access (using Up/Down PBs) to the most commonly used metered parameters: C u r r e n t Voltage Power (Watts) Power (Vars) Power (VA) E n e r g y D e m a n d Power Factor F r e q u e n c y % T H D Distortion Factor C u s t o m Several parameters will require multiple screens for complete display of all available information. Up/Down will toggle through all displays. Analysis Modes: (USER S MANUAL SECTION 5-7) Analysis screens show detailed system information relative to the selected category. All historical and event information is accessed in the analysis modes. Trend Analysis Event Analysis Harmonic Analysis Demand Analysis : (USER S MANUAL SECTION 5-4) This password protected mode is used to configure the Unit. Use to specify General Setup Settings and for advanced features. Reset Mode: (USER S MANUAL SECTION 5-10) Using this password protected mode, the operator can reset or clear certain items such as Min/Max values, Alarm Triggers, Relays and Peak Demand V a l u e s. Help Mode: (USER S MANUAL SECTION 5-3) The IQ Analyzer displays various Help screens and useful information relating to device operation, programming and troubleshooting. Communications (USER S MANUAL SECTIONS 5-8) The IQ Analyzer is an IMPACC (Integrated Monitoring Protection and Control Communications) compatible device. It can be remotely monitored, controlled and programmed when equipped with the communications option. The small, addressable communications module (IPONI), is mounted to the back of the IQ Analyzer. Information Display Type Current Voltage Power Energy Demand Power Factor Frequency % THD Distortion Factor Custom C o m m e n t s Phase A, B, C, Average Neutral Ground (separate CT inputs for each) Phase A-B, B-C, C-A, Average Phase A-N, B-N, C-N, Average Neutral - Ground System 1 and Phase A, B, C Real (Watts) Reactive (vars) Apparent (VA) Forward, Reverse, Net Real (kwh) Reactive (kvarh) Apparent (kvah - Net only) System Current (A) System Real Power (kw) System Reactive Power (kvar) System Apparent Power (kva) System and Phase A, B, C Displacement 2 Apparent 3 Hz Time Date Currents Phase A, B, C Neutral Voltages Phase A-B, B-C, C-A Phase A-N, B-N, C-N K-Factor 4 (of Event) CBEMA Derating Factor 5 ( T H D F ) Crest Factor 6 Discrete Input and Output Status Analog Input Reading User can program two screens to display any combination of seven Meter Menu parameters per screen via the Custom Screens option under Display Manager. (PGM/DISPMGR/CUST) 1 Line to neutral values do not apply for 3-wire system, use system values. 2 Fundamental watts to VA. 3 Total rms watts to VA. 4 K-Factor: A derating factor that is essentially the sum of the squares of individual harmonic currents times the squares of their harmonic number (i.e., multiples of fundamental). One for each current is displayed with largest recorded in Event metered data. 5 CBEMA Factor: A transformer harmonic derating factor defined as a pure sine wave s crest factor (1.414) divided by the measured crest factor. 6 Crest Factor: The ratio of peak current to rms current. 7

General (USER S MANUAL SECTIONS 5-1) Mounting (USER S MANUAL SECTIONS 4-2) When the IQ Analyzer is initially powered up, it is in Display Mode. The Normal LED will blink green and the Current LED will glow red. The display will show phases A, B and C currents in amperes for the system being monitored. IA= 100.0 IB= 99.0 IC= 97.0 A M P E R E S TRND EVNT HARM DEMD Initial Meter Menu Current Screen The IQ Analyzer is typically mounted on an enclosure door. This installation makes it necessary to prepare a cutout into which the device will be placed. Top, bottom and two center side holes are used to mount the unit. A flange mounting option and separate NEMA 12/3R enclosure are available. Contact your local distributor or sales office. The Up and Down pushbuttons (PBs) provide fast access to other Meter Menu parameters such as those outlined in the table. The Function pushbuttons (F1-F4) access TRND, EVNT, HARM and DEMD from the Display Mode. These are Analysis Modes for Trend, Event, Harmonic and Demand i n f o r m a t i o n. Note on Sign Convention (USER S MANUAL SECTIONS 5-22) As a factory default, lagging vars and power factor are represented as negative values at the load. This is a negative sign convention consistent with P=VI. The alternative is a power engineering convention which uses P=VI such that consumption of power is positive. This sign convention can be changed in the under Power/ Energy Options in General Setup. Changing this setting will have no effect on the unsigned LEAD- ING KVAR-HR and LAGGING KVAR-HR energy readings. However, the NET KVAR-HR energy will begin counting in the opposite direction. FLUSH MOUNT DRILLING PATTERN Manual Capture (USER S MANUAL SECTIONS 5-7.2.5.12) Capture and store system values for analysis and to aid in verifying proper operation of the IQ Analyzer by using Manual Capture. Enter the Harmonic Analysis Mode from Display Mode using the F3 Function PB. In the Harmonic Analysis Mode, the unit captures new system measurements when the F4 pushbutton (NEW) is pressed twice. (F3, F4, F4) NOTE: For proper operation, an Event Trigger must be set to Manual Capture. This can be done in the Event Triggers section of the. FLANGE MOUNT DRILLING PATTERN 9

Wiring (USER S MANUAL SECTIONS 4-3) Wiring installation for the IQ Analyzer must follow a suitable Wiring Plan Drawing and conform to applicable Federal, State and Local codes. Wires to the terminal blocks must not be larger than AWG No. 14. Larger wire sizes may be used on the CT connections when using appropriate ring terminals. The following two figures show typical wiring diagrams. Additional wiring diagrams are shown in the User s Manual. WARNING! Wiring procedures must be performed only by qualified personnel who are familiar with the IQ Analyzer and its associated electrical equipment. Ensure that incoming ac power (or foreign power) sources are turned off and locked out prior to performing any electrical work. Failure to do so may result in serious injury or death, or equipment damage. The only exception is when connecting/ disconnecting ribbon cables at J2 or J3. 11

rogramming General Setup Settings Worksheet Quick Start Procedure (USER S MANUAL SECTIONS 4-5) During initial setup of your IQ Analyzer, use Steps 1-5 below after the IQ Analyzer has been mounted and wired using Sections 4-2 and 4-3, along with Figures 4-9 to 4-34 of the User s Manual as a reference. STEP #1: Complete the General Setup Settings Worksheet. This will require an understanding of the electrical system configuration and transformer ratios. STEP #2: Enter the of the IQ Analyzer. If this is an initial startup, use factory default passwords (10000 or 44444). (Program, F2, F4) STEP #3: Enter General Setup Settings using the F1-F4 PBs from the information on page 13. (An example is shown on the following pages.) STEP #4: Examine, understand and verify Metered Values. Ensure display matches your system. STEP #5: Troubleshoot problems. Use the guide provided, the Help Mode and/or the User s Manual as a reference in troubleshooting. Type of system (select one) 3 Phase/4 Wire 1 Phase/3 Wire 3 Phase/3 Wire 1 Phase/2 Wire Phase Rotation (if Step 1 was 3 Phase, select one) ABC Rotation CBA Rotation Choose Frequency (select one) 25Hz 50Hz 40Hz 60Hz Incoming Line-to-Line Voltage Enter from 100-600 Vac PT Primary Rating (120 volt secondary) Enter from 120-500,000 volts, CT Primary Rating (5A secondary) Enter from 5-10,000A, GND CT Primary Rating (5A secondary) Enter from 5-10,000A, Programming Options (select one) Faceplate Only Input3 Key Only Faceplate & IMPACC (recommended) Input3 Key & IMPACC Energy Resolution for Wh, varh, & VAh (select one) Kilowatt-hours Megawatt-hours Var Sign Convention (select one) Lagging vars & PF negative at load Lagging vars & PF positive at load Date and Time Enter date and time if required Change Password Enter new 5 digit password if required 13

Programming Example (USER S MANUAL SECTION 6) Meter a typical load on a 480 volt, 3 phase 3 wire (ABC phase rotation), 60Hz system with 1200/5 CTs, 50/5 ground CTs and no PTs. (Assume Kilowatt-hour energy resolution, and lagging vars & Power Factor negative at load.) NOTE: The IQ Analyzer must be programmed to a PT ratio of 120/120 or unity for the IQ Analyzer to recognize there are no PTs. From Main Menu Program PB Press Up (F2), then Enter (F4) to input default password 10000 Top Level Entry Screen Incorrect Password Exits Automatically P G M - M A I N LAST PROGRAMMED: 6/11/97 11:48:07A INCOM ADDR:000 SOFTWARE VER. 1.14 ENTER PASSWORD:00000 (00000=VIEW ONLY PW) --> UP DOWN ENTER Use (F2) or (F3) PBs to Move to Incoming Line-Line Voltage Establish and Enter 480 Volts Use F2-F4 PBs to Move to PT Primary Rating Incoming L-L Voltage L-L Voltage Rating with 3 Digits Incoming L-L Voltage PT Primary Rating P G M / G E N / I N V O L T APPLIED TO VOLTAGE INPUT TERMINALS A,B, C, N OF IQ ANALYZER (100 TO 600 VAC): 4 8 0 --> UP DOWN ENTER Top Level Menu General Setup Type of System P G M CHOOSE CATEGORY: GENERAL SETUP ANALOG INPUTS ANALOG OUTPUTS DISCRETE INPUTS EVENT TRIGGERS SEL UP DOWN ENTER P G M / G E N SELECT PARAMETER: TYPE OF SYSTEM F R E Q U E N C Y PT PRIMARY RATING CT PRIMARY RATING SEL UP DOWN PGDN Use F1-F4 PBs to Establish and Enter 120 Volts Use F2-F4 PBs to Move to CT Primary Rating PT Primary Rating with 6 Digits PT Primary Rating CT Primary Rating P G M / G E N / P T PT PRIMARY L-L RATING 120 TO 500,000 V (SEE USER S MANUAL IF NOT USING 120V SECONDARY PTS) 0 0 0 1 2 0 : 1 2 0 --> UP DOWN ENTER Use F1-F3 PBs to Move an Select 3 Phase/3 Wire Choose Type of System with Parameters Phase Rotation with Parameters P G M / G E N / T Y P E 3 PHASE/4 WIRE *3 PHASE/3 WIRE SINGLE PHASE/3 WIRE SINGLE PHASE/2 WIRE SEL UP DOWN P G M / G E N / T Y P E / 3 P H 3 W *ABC - PHASE ROTATION CBA - PHASE ROTATION Establish and Enter 1200 A CT Primary Rating with 5 Digits CT Primary Rating P G M / G E N / C T CURRENT TRANSFORMER PRIMARY RATING: 5 TO 10,OOO AMPS (MUST BE 5 AMP SECONDARY CT) 0 1 2 0 0 : 5 --> UP DOWN ENTER Use F2-F4 PBs to Move and Enter ABC Use (F2) or (F3) PBs to Move to Frequency Use F2-F4 PBs to Move to and Enter 60Hz Type of System Frequency Frequency Choices Type of System continued on next page UP DOWN ENTER P G M / G E N SELECT PARAMETER: TYPE OF SYSTEM F R E Q U E N C Y PT PRIMARY RATING CT PRIMARY RATING SEL UP DOWN PGDN P G M / G E N / F R E Q 25 HZ 40 HZ 50 HZ * 60 HZ UP DOWN ENTER P G M / G E N SELECT PARAMETER: TYPE OF SYSTEM F R E Q U E N C Y PT PRIMARY RATING CT PRIMARY RATING SEL UP DOWN PGDN Use F2-F4 PBs to move to GND CT Primary Rating Establish and Enter 50 A Press Program PB to exit GND CT Primary Rating GND CT Primary Rating with 5 Digits GND CT Primary Rating P G M / G E N SELECT PARAMETER: F R E Q U E N C Y PT PRIMARY RATING CT PRIMARY RATING GND CT PRIMARY RATING SEL UP DOWN PGDN P G M / G E N / G C T GND CURR TRANSFORMER PRIMARY RATING: 5 TO 10,000 AMPS (MUST BE 5 AMP SECONDARY CT) 0 0 0 5 0 : 5 --> UP DOWN ENTER P G M / G E N SELECT PARAMETER: F R E Q U E N C Y PT PRIMARY RATING CT PRIMARY RATING GND CT PRIMARY RATING SEL UP DOWN PGDN 15

Time/Date Programming Example Password Programming Example From Main Menu Program PB Top Level Entry Screen Use F1-F3 PBs to Move and Select Parameter to Change Parameter Digit From Main Menu Program PB Top Level Entry Screen Move and Select Change Password 5 Digit Password Press Up (F2), then Enter (F4) to input default password 10000 Incorrect Password Exits Automatically Establish and Enter Desired Data Parameter Press Up (F2), then Enter (F4) to input default password 10000 Incorrect Password Exits Automatically Establish and Enter New Password Changed Password Top Level Menu General Setup Press Program PB to Exit Top Level Menu General Setup Press Program PB to Exit Type of System Type of System Move and Select Change Date/Time Month 17

oubleshooting (USER S MANUAL SECTIONS 7) Troubleshooting (USER S MANUAL SECTIONS 7) ymptom Probable Cause Possible Solutions(s) Operator Panel icator LED s off. e or more volte phases read orrectly. wer parameters att, var, VA, wer Factor) d incorrectly. orrect readings one or more rents. Line voltage level is d e f i c i e n t. Separate source control power is deficient. ac line connections (or optional external PTs) are not properly w i r e d. Blown or loose fuse(s). Blown or loose fuse(s). Incorrect voltage settings. Phasing for voltage and current is mismatched. CT polarity is reversed. Incorrect current transformer ratio setting. Locate cause of deficiency in ac line. Locate deficiency in the ac control power l i n e. Verify that the ac line (and/or PTs) are wired p r o p e r l y. Verify line voltage with multimeter. Check power module fuse(s) on affected phase(s). These are located just above voltage inputs (behind the cover of power module). Reseat or replace fuse(s) as necessary. 1 Verify line voltage with multimeter. Check power module fuse(s) on affected phase(s) located just above the voltage inputs behind the cover of power module. Reseat or replace fuse(s) as n e c e s s a r y. 1 Verify correct settings programmed in the IQ Analyzer for system type,l-l voltage and PT rating. Capture an event and compare phase angles of Va, Vb, Vc, Ia, Ib, Ic to detect possible wiring error(s). Verify connections per wiring diagrams. Reverse CT leads. Verify proper wiring and grounding. Verify incoming current using a separate a m m e t e r. Verify proper CT ratio s e t t i n g s. Check CT wiring and g r o u n d i n g. Unit displays: Hardware Failure Register Failure Multiply Failure Divide Failure Logic Failure A d d / S u b t r a c t F a i l u r e Unit displays: Internal RAM E r r o r External RAM E r r o r External ROM E r r o r Unit displays: Reverse Sequence Unit fails to capture Harmonic Data when Manual Capture is pressed. Unit fails to communicate over IMPACC network. Display goes blank after several minutes. Unit setpoints unchanged upon exiting program mode. Possible IQ Analyzer hardware failure. IQ Analyzer hardware error. IQ Analyzer has detected phasing difference between programmed setpoint and actual system parameters. No manual capture event trigger has been programmed. Wrong or conflicting address set on IPONI. Blown fuse on IQ Analyzer. Communications wiring error. IPONI failure. Display Manager Screen Saver Option is set to blank rather than dim. Unit was in View-Only mode using password (00000). Reboot Unit by mometarily removing power cable at connector J2. Replace Unit. Reboot Unit. Replace Unit. Verify actual system phasing. Capture an event and compare phase angles of Va, Vb, Vc, Ia, Ib, Ic to detect possible wiring error(s). Verify that IQ Analyzer setpoint matches actual system phasing. Verify IQ Analyzer connections. Enter and set up an Event Trigger for Manual Capture. Check that IPONI has a unique address on the system and that software is addressing proper unit. Check input/output fuse adjacent to IQ Analyzer communication connector. Replace if necessary. 1 Verify wiring is in conformance with IMPACC wiring rules. Press any pushbutton to activate display. Program longer timeout in Meter Menu Return Time in Display Manger. Re-enter program setpoints using proper password. Customer established or factory default (44444 or 10000). ower Module Fuse: Buss KTK-R-3/4 or equivalent (3/4 amp). 1 I/O Fuse: Littlefuse Plug-in Microfuse, Catalog #273.250, 0.25A, 125V or equivalent. 8 19

C u t l e r- H a m m e r For additional information or technical assistance, contact: ADVANCED PRODUCT SUPPORT CENTER 1-800-809-2772 w w w. c u t l e r h a m m e r. e a t o n. c o m