Relays. Switching & Controls. Selection Guide

Similar documents
Relays. Switching & Controls. Selection Guide

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal

Relays. Switching & Controls.

This document provided by Barr-Thorp Electric Co., Inc

Relays & Sockets. Switching & Controls.

Relays & Sockets. Switching & Controls.

RJ Series Slim Power Relays

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

6mm Interface Relays RV8 Series

Relays & Sockets. General-purpose electromechanical relays and sockets

RU Series Universal Relays

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Sockets. SU Series: DIN Rail Snap-Mount Sockets. F-6 USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC ➀➁➄➅ ➁➂➃➄

RU Series. Full featured universal miniature relays. Designed with environment taken into consideration.

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

GT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

Safety Monitoring Relays

Timers GE1A. GE1A Series ON Delay Timers Single Function

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

SPST-NO SPDT DPST-NO DPDT

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Model Number Structure

20 Series Power Relays

SH Series: DIN Rail Snap-Mount Sockets. SH1B Sockets " (17mm) 0.172" (4.4mm) 0.216" (5.5mm) Ø 0.140" (3.6mm) 2.613" (67mm) 2.

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

onlinecomponents.com

62 Series - Power relays 16 A. Features / /

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

OMRON MK-I / -S RELAY

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

Model Number Structure

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

MINIATURE RELAY FOR WIDER APPLICATIONS

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

The power in relays and timers since Catalogue

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

GT3W Series Dual Time Range Timers. CSA Certified File No.LR58183 LR96764 LR83814

General-purpose Relay

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

38 Series - Relay interface modules A. Features /

Details on the New G2RS

1a/1c/2a/2c/5A/10A power relays for power supply

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi

2 or 4 pole changeover contact Plug-in/Faston 187

Transistor drive 2c/4c 5A slim power relays

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

1a/1c/2a/2c/5A/10A power relays for power supply

Compact Relay Family with Forcibly Guided Contacts

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

40 Series - Miniature P.C.B. Relays A

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

Compliant with European standards 1a/1c 6A Slim power relays

2 POLES 5 A LOW PROFILE TYPE

General-purpose Relay

Song Chuan / Relay Catalog 507

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

G2RL-1A G2RL-1 G2RL-2A G2RL-2

2 POLES 8 A LOW PROFILE TYPE

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

General-purpose Relay

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories


Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

38 Series - Relay interface modules A

TV-15, 30 AMP (1 Form A) Power Relay

1a/1c 5A/10A small power relays

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

GENERAL PURPOSE RELAYS

COMPACT PC BOARD POWER RELAY

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

HC RELAY PRODUCT TYPES

38 Series - Relay interface modules A

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS

Slim compact safety relay

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

38 Series - Relay Interface Modules A

62.22 Copper side view

Palm-sized, 16-channel Relay Terminals

Classification Enclosure rating Contact form Contact material

10 A MINIATURE POWER RELAY mm inch. 2 Form A, 1 Form A 1 Form A. Initial breakdown voltage* 2. Vibration resistance.

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

48 Series - Relay interface modules A. Features

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays

MY-GS CSM_MY-GS_DS_E_2_1

Transcription:

Switching & Controls Selection Guide... 7 General Purpose Relays... RVH Series 6mm Interface Relays... RVS Series 6mm Interface Relays... RJ Series Slim Power Relays... RQ Series PCB Relays... 3 RH Series Compact Power Relays... 3 RR Series Power Relays... RU Series Universal Relays... 6 RY/RM Series Miniature Relays... 6 RFV Force Guided Relays... 76 Solid State Relays... RSC Series Solid State Relays... RSS Series Panel Mount Solid State Relays... www.idec.com/relays Relays Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers Table of Contents LED Lighting - Pg. Automation & Sensing - Pg. 37 Safety - Pg. 3 Switching & Controls - Pg. Index - Pg.

Selection Guide Switches & Pilot Lights General Purpose Relays Selection Guide Series RVH Series RJ Series RQ Series RH Series RR Series Appearance Signaling Lights Page 0 6 36 0 0 Contact Configuration form C (SPDT) SPDT, SPST, DPDT, DPST SPDT, DPDT SPDT, DPDT, 3PDT, PDT SPDT, DPDT, 3PDT Terminal Screw, Spring-clamp Blade or PCB PCB Blade or PCB Pin or Blade Contact Rating (resistive) Contact Material Approvals 6A 30V DC/0V AC Silver-Nickel with gold plating Class I Division Hazardous Locations SPDT: A/6A, 30V DC/0V AC DPDT: A, 30V DC/0V AC SPDT: A, 6A DPDT: A 0A, 30V DC/0V AC /3HP, 0V AC /6HP, 0V AC Silver-Nickel alloy Silver-Nickel alloy Silver-Cadmium Oxide Silver 0A, 30V DC/ 0V AC /3HP, 0V AC /HP, 0V AC Timers Series RU Series RY/RM Series RFV Series Appearance Contactors Terminal Blocks Page 7 66 77 Contact Configuration DPDT, PDT DPDT, PDT DPDT PDT or 6PDT Terminal Blade or PCB Blade or PCB Contact Rating (resistive) Contact Material Approvals DPDT: 0A, 30V DC/0V AC PDT: 6A, 30V DC/0V AC /0 HP, 0V AC DPDT Silver Tin Oxide Indium PDT Gold-Silver Alloy on Silver RY: DPDT: 3A, 30V DC/0V AC PDT: A, 30V DC/0V AC A, 30V DC/0V AC 6A, 0V AC 6A 0V DC Gold plated silver Silver Silver alloy * Circuit Breakers *with socket www.idec.com

Selection Guide Bifurcated Contacts Relays Selection Guide con t Latching Relays Series RJ Series RU Series Series RRKP Series RYKS Series Appearance Appearance Page 6 7 Page visit www.idec.com/relays Contact Configuration DPDT PDT Contact Configuration DPDT DPDT Terminal Blade or PCB Blade or PCB Terminal Pin Blade Contact Rating (resistive) A 0V AC/30V DC 3A 0V AC/30V DC Contact Rating (resistive) 0A, 30V DC 0A, 0V AC 3A, 30V DC 3A, 0V AC Contact Material Gold clad Gold Silver Alloy on Silver Contact Material Silver Silver, gold-plated Approvals Solid State Relays Series RVS Series RSC Series RSS Series Appearance Page page 6 Output Configuration Form A (SPST-NO) Form A (SPST-NO) Form A (SPST-NO) Output Rating Output Approvals V: 3.A, V DC: 00mA, 0 V AC: A V - MOSFET, V DC Photo-transistor, 0V AC: Triac (when using combination of RV relay and SV socket) 0A, 30A, A - 600V AC Dual SCR (zero crossing) 0A, A, 0A, 7A, 0A - 660V AC Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada

RVH and RVS Switches & Pilot Lights Signaling Lights Key features: Class I, Division and Class I, Zone Hazardous Location options (electromechanical relays only) Solid State relay versions available Only 70mm in height from DIN rail Gold-plated contacts (electrical mechanical relays only) Pre-assembled relay and DIN mount socket Universal screw terminals (flat and phillips) or spring clamp terminals Universal AC/DC socket with built-in surge suppression and green LED 6A contact rating (electromechanical relays only) Lever for easy locking and removal of relay Operating temperature of -0ºC ~ +70 C (-0 C ~ +60 C for SSR) RoHS compliant RV Series 6mm Interface Relays Electromechanical CD (screw terminal) Solid State (spring clamp) (when using combination of RV relay and SV socket) Top view with marking plate 70 mm RVH Electromechanical Part Numbers Top view with marking plate 70 mm Electromechanical General Purpose and Hazardous Location (Class I, Division ) Relays Screw Terminals Spring Clamp Terminals Timers Complete Unit Complete Unit Relay Only Relay Only Contactors Terminal Blocks Coil Voltage Complete Part Number General Purpose Hazardous Location (CD) General Purpose Hazardous Location (CD) Replacement (Relay Only) Complete Part Number Replacement (Relay Only) Complete Part Number Replacement (Relay Only) Complete Part Number Replacement (Relay Only) Circuit Breakers DC AC/DC 6V RVH-L-D6 RVH-G-D RVH-L-D6-CD RVH-G-D-CD RVH-S-D6 RVH-G-D RVH-S-D6-CD RVH-G-D-CD V RVH-L-D RVH-G-D RVH-L-D-CD RVH-G-D-CD RVH-S-D RVH-G-D RVH-S-D-CD RVH-G-D-CD V RVH-L-D RVH-G-D RVH-L-D-CD RVH-G-D-CD RVH-S-D RVH-G-D RVH-S-D-CD RVH-G-D-CD V RVH-L-D RVH-G-D RVH-L-D-CD RVH-G-D-CD RVH-S-D RVH-G-D RVH-S-D-CD RVH-G-D-CD V RVH-L-D RVH-G-D RVH-L-D-CD RVH-G-D-CD RVH-S-D RVH-G-D RVH-S-D-CD RVH-G-D-CD V RVH-L-AD RVH-G-D RVH-L-AD-CD RVH-G-D-CD RVH-S-AD RVH-G-D RVH-S-AD-CD RVH-G-D-CD V RVH-L-AD RVH-G-D RVH-L-AD-CD RVH-G-D-CD RVH-S-AD RVH-G-D RVH-S-AD-CD RVH-G-D-CD V RVH-L-AD RVH-G-D RVH-L-AD-CD RVH-G-D-CD RVH-S-AD RVH-G-D RVH-S-AD-CD RVH-G-D-CD V RVH-L-AD RVH-G-D RVH-L-AD-CD RVH-G-D-CD RVH-S-AD RVH-G-D RVH-S-AD-CD RVH-G-D-CD 60V RVH-L-AD60 RVH-G-D60 RVH-L-AD60-CD RVH-G-D60-CD RVH-S-AD60 RVH-G-D60 RVH-S-AD60-CD RVH-G-D60-CD 0V - V RVH-L-AD0 RVH-G-D60 RVH-L-AD0-CD RVH-G-D60-CD RVH-S-AD0 RVH-G-D60 RVH-S-AD0-CD RVH-G-D60-CD 0V - 0V RVH-L-AD0 RVH-G-D60 RVH-L-AD0-CD RVH-G-D60-CD RVH-S-AD0 RVH-G-D60 RVH-S-AD0-CD RVH-G-D60-CD 0 www.idec.com

RVH and RVS Electromechanical Coil Ratings Rated Voltage DC AC/DC Rated Current ±% (ma)* Circuit AC Resistance ±% (Ω)* Circuit DC Resistance ±% (Ω)* Pickup Voltage Operating Characteristics Dropout Voltage Maximum Allowable Voltage Power Consumption 6V 3-70 0.W V.6-0.W V.6-0 0% max 7% min 0% 0.W V.6-0 0.W V 0.6-70 0.W V. 7 00 0.W V 3.3 36 3 0.W V 3.7 730 70 0.33W V 0 30 0% max 7% min 0% 0.W 60V 3. 7600 70 0.W 0V - V 3. - 3. 370-30 30-300 0.W 0V - 0V 3.3-3.6 6670-66070 60-670 0.W *±0% for 6V, V and V Electromechanical Contact Ratings Allowable Contact Power Resistive Load 00VA, 0W DC Rated Load Resistive Load 0V AC 6A, 30V DC 6A Allowable Switching Current 6A Allowable Switching Voltage 00V AC, V DC Allowable Switching Power 00VA, 0W DC Minimum Applicable Load 6V DC/0mA Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada

RVH and RVS Switches & Pilot Lights Screw Terminals RVS Solid State Relays Part Numbers Spring Clamp Terminals Signaling Lights Input Voltage Output Voltage New New Complete Part Number Complete Part Number V DC, 3.A RVS-L-D-D6 RVS-S-D-D6 DC 6V V V DC, 0.A RVS-L-D-D6 RVS-S-D-D6 0V AC, A zero cross RVS-L-A0Z-D6 RVS-S-A0Z-D6 0V AC, A random RVS-L-A0-D6 RVS-S-A0-D6 V DC, 3.A RVS-L-D-D RVS-S-D-D V DC, 0.A RVS-L-D-D RVS-S-D-D 0V AC, A zero cross RVS-L-A0Z-D RVS-S-A0Z-D 0V AC, A random RVS-L-A0-D RVS-S-A0-D Solid State Output Ratings Typical Input Voltage V DC V DC 0V AC Output Device MOSFET Phototransistor Triac Operating Voltage Range 0-V DC 0-V DC -0V AC (7-63Hz) Maximum Load Current 3.A 00mA A Minimum Load Current ma ma 70mA V DC, 3.A RVS-L-D-A0 RVS-S-D-A0 Maximum Blocking Voltage 30V DC 60V DC 600V AC Timers AC 0V V DC, 0.A RVS-L-D-A0 RVS-S-D-A0 0V AC, A zero cross RVS-L-A0Z-A0 RVS-S-A0Z-A0 0V AC, A random RVS-L-A0-A0 RVS-S-A0-A0 V DC, 3.A RVS-L-D-A0 RVS-S-D-A0 Maximum Surge Current A (0ms) 300mA (0ms) 0A pk (6.6ms) Maximum lt for Fusing 60A² sec Typical On-State Leakage Current 0.V V.V (peak) 0V V DC, 0.A RVS-L-D-A0 RVS-S-D-A0 0V AC, A zero cross RVS-L-A0Z-A0 RVS-S-A0Z-A0 0V AC, A random RVS-L-A0-A0 RVS-S-A0-A0 Maximum Off-State Leakage Current Switching Configuration 0.00mA 0.00mA ma Normally Open Normally Open Normally Open Contactors Terminal Blocks Circuit Breakers Solid State Input Ratings Type Zero Crossing Random Crossing Control Voltage Range Output / Input Voltage Pickup Voltage Dropout Voltage Input Current Maximum Operation Time Maximum Release Time.-V DC V DC / 6V DC.V DC.V DC 0mA±0%(±6VDC) 0μs 00μs.6-30V DC V DC / V DC.6V DC V DC ma±0%(±vdc) 30μs 00μs 6-3V AC V DC / 0V AC 6V AC V AC 0mA±0%(±0VAC) ms ms -6V AC V DC / 0V AC V AC V AC 0mA±0%(±0VAC) ms ms.-v DC V DC / 6V DC.V DC.V DC 6mA±0%(±6VDC) 0μs 300μs.6-30V DC V DC / V DC.6V DC V DC 7mA±0%(±VDC) 0μs 300μs 6-3V AC V DC / 0V AC 6V AC V AC 0mA±0%(±0VAC) ms ms -6V AC V DC / 0V AC V AC V AC 0mA±0%(±0VAC) ms ms.-v DC 0V AC / 6V DC.V DC V DC ma±0%(±6vdc) 0ms 0ms.6-30V DC 0V AC / V DC.6V DC V DC 7mA±0%(±VDC) 0ms 0ms 6-3V AC 0V AC / 0V AC 6V AC V AC 0mA±0%(±0VAC) 6ms 0ms -6V AC 0V AC / 0V AC V AC V AC 0mA±0%(±0VAC) 6ms 0ms.-V DC 0V AC / 6V DC.V DC V DC ma±0%(±6vdc) 300μs 0ms.6-30V DC 0V AC / V DC.6V DC V DC 7mA±0%(±VDC) 300μs 0ms 6-3V AC 0V AC / 0V AC 6V AC V AC 0mA±0%(±0VAC) ms 0ms -6V AC 0V AC / 0V AC V AC V AC 0mA±0%(±0VAC) ms 0ms www.idec.com

RVH and RVS 7. Electromechanical Relays RVH-L Screw Terminal (mm) 7. A(-) Coil A(+) Coil Solid State Relays RVS-L Screw Terminal (mm) 7. A A(-) Coil A(+) A Coil 3.0.0 3.0 3.0 3..0 NO (3+) COM NO NC (3+) COM 3(3+) (NC) 6.6 6.6 6.6 6. RVH Replacement Electromechanical Relay (mm)..0 3..0 0. 0. 0. 3.7.0.0.0.0 6.3 DIMENSIONS RVH-S Spring Clamp Terminal (mm) 7. A(-) Coil A(+) Coil 3.0 3. RVS-S Spring Clamp Terminal (mm) 7. A A NO (3+) COM (NC) 6. 6. 3.0 6. 3. Internal Connection bottom view (mm) A A (3+) 3(3+) 6.6 6.6 6. 7. 7. Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers A A A A 00-6-IDEC (33) USA & Canada 3

RVH and RVS Timers Signaling Lights Switches & Pilot Lights Jumpers, Spacer, and Screwdriver Item Color Part Number Note,, Jumper (0 combs) Black SVZ-J0B Spacer (circuit separator) Note 3, Screwdriver Gray Blue SVZ-J0W SVZ-J0S - SVZ-SAW - BCS-SD0. Jumper combs come with 0 points, if shorter lengths are needed simply cut off the excess points.. Ensure that the total current to the jumper does not exceed the overall rated current (Rated current: 6A). 3. Width of spacer: mm. When using a cut jumper, please use a spacer on the cut side. For additional information see instruction sheet. Accessories Marking Plates (Blank and Pre-marked) Item Part Number Engraving Vertical Orientation Horizontal Orientation SVZ-PW0 blank SVZ-PW0-➀-0-0 SVZ-PW0-➀-0-0 SVZ-PW0-➀-30-30 SVZ-PW0-➀3-0 3-0 SVZ-PW0-➀-0-0 SVZ-PW0-➀-60-60 SVZ-PW0-➀6-70 6-70 SVZ-PW0-➀7-0 7-0 SVZ-PW0-➀-0-0 SVZ-PW0-➀-00-00 SVZ-PW0-➀A-J SVZ-PW0-➀K-T SVZ-PW0-➀U-Z SVZ-PW0-➀GROUND SVZ-PW0-➀AC A-J K-T U-Z. In place of ➀ insert orientation code: V=Vertical, H=Horizontal. Each unit has 0 pieces (marking plates). Marking Plate Placement Marking Plate Locking Lever RV Insert Dimensions (mm) SVZ-PW0* Marking Plate SVZ-SAW Spacer 3.0 Cut Contactors 6. 0..0 6. 6.0 7. 66. *Available blank or pre-marked. Terminal Blocks SVZ-J0* Jumper 6.. 3.0 6.7.0 Circuit Breakers *Available in black, gray and blue. 0.0 6.0.3. www.idec.com

RVH and RVS RVH Replacement Electromechanical Relay Maximum Switching Power AC Contact Current (A) 0. 0. AC Resistive load AC Inductive load (p. f=0.3) 0. 0 0 30 00 00 300 00 Contact Voltage (V) Characteristics Maximum Switching Power DC Solid State Continuous Load Current vs. Ambient Temperature Curves V DC Load Current (Amperes).0 3. 3.0... 0.6 0.0 No air gap Contact Current (A) 0 0 0 30 0 0 60 0V AC Zero Cross Load Current (Amperes).3.0.7.3.0 0.7 0.3 0.0 Legend Air gap 6. mm No air gap Air gap 6. mm Ambient Temperature ( C) 0 0 0 30 0 0 60 Ambient Temperature ( C) 0. 0. DC Resistive load DC Inductive load (L/R = 6ms) 0. 0 0 30 00 00 300 00 Contact Voltage (V) V DC Load Current (Amperes) 0. 0.0 0.0 0.06 0.0 0.0 No minimum air gap required 0.00 0 0 0 30 0 0 60 0V AC Random Cross Load Current (Amperes) Ambient Temperature ( C) 0.0 0 0 0 30 0 0 60 Ambient Temperature ( C) No spacing required between units. Spacing of 6.mm minimum required between units Not Recommended.3.0.7.3.0 0.7 0.3 Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada

RJ Switches & Pilot Lights Signaling Lights RJ Series Slim Power Relays Key features: Compact and rugged power relays. Large switching capacity Compact housing only.7-mm wide. Large contact rating RJ (-pole): 6A (UL general use rating @0V AC) RJ (-pole): A Non-polarized LED indicator available on blade type. IDEC s unique light guide structure enables high visibility of coil status from any direction. The smallest width for -pole/bifurcated contact relay Excellent electrical and mechanical life. Electrical life: 00,000 operations (AC load) Mechanical life: 30 million operations (AC coil) RoHS directive compliant (EU directive 00//EC). Contains no lead, cadmium, mercury, hexavalent chromium, PBB or PBDE. Diode model: Diode reverse withstand voltage: 000V UL recognized, CSA certified, EN compliant. UL0 UL File No. E6 CSA C. No. 603 CSA File No. LR3 Part Number Selection EN60- VDE (REG.-Nr B3) EN60- EC Low Voltage Directive Timers Style Terminal Contact Model Part Number SPDT Coil Voltage Code (Standard Stock in bold) Standard RJS-C-0 A, A0, A0, A0, A0, with LED RJS-CL-0 D, D, D, D00 with Surge Suppresion Diode RJS-CD-0 with LED & Surge Suppresion Diode RJS-CLD-0 D, D, D, D00 Contactors Terminal Blocks Blade PCB Standard RJS-C-0 A, A0, A0, A0, A0, with LED RJS-CL-0 D, D, D, D00 with Surge Suppresion Diode RJS-CD-0 D, D, D, D00 with LED & Surge Suppresion Diode RJS-CLD-0 DPDT Standard Bifurcated contacts (without LED indicator) RJS-C-0 A, A, A0, A0, Bifurated contacts (with LED indicator) RJS-CL-0 D, D, D, D00 Bifurcated contacts diode (without LED indicator) RJS-CD-0 Bifurcated contacts diode (with LED indicator) RJS-CLD-0 D, D, D, D, D00 SPDT Standard RJV-C-0 High Capacity RJV-CH-0 SPST-NO Standard RJV-A-0 A, A0, A0, A0, A0, High Capacity RJV-AH-0 D, D6, D, D, D, D00 DPDT Standard RJV-C-0 DPST-NO Standard RJV-A-0 DPDT Bifurcated contacts RJV-C-0 A, A, A0, A0, DPST-NO Bifurcated contacts RJV-A-0 D, D, D, D, D00 Circuit Breakers Ordering Information When ordering, specify the Part No. and coil voltage code: (example) RJS-C- A0 Part No. Coil Voltage Code 6 www.idec.com

RJ Coil Voltage Table Coil Voltage Code A A A0 A0 A0 A0 D D6 D D D D00 Coil Rating V AC V AC 0V AC 0V AC 0V AC 0V AC V DC 6V DC V DC V DC V DC 00-0V DCV DC Sockets Blade Models PCB Models Accessories Relays Standard DIN Rail Mount Finger-safe DIN Rail Mount PCB Mount RJS (Std) SJS-0BW SJS-07LW SJS-6 RJS (Std)/RJS SJS-0BW SJS-07LW SJS-6 RJV (Std) SQV-07B* SQV-63* RJV (HC) RJV/RJV SQV-07B* SQV-63* Shown with optional marking plate. *Hold-down clip or spring must be removed to use with RJ PCB relays. Item Appearance Use with Part No. Remarks Aluminum DIN Rail ( meter length) DIN Rail End Stop All DIN rail sockets BNDN000 DIN rail BNL. mm wide. Marking Plate Finger safe sockets (ONLY) SJZ-PWPN0 0 pieces per pack Replacement Hold Down Springs Part Number Used With Socket SJZ-CM SJS-0BW, SJS-07LW, SJS-0BW, SJS-07LW SQZ-C SQV-07B, SQV-07B SQZ-C63 SQV-63, SQV-63 Jumpers for SJ Sockets Poles Part Number Quantity SJZ-JF Must SJZ-JF purchase in SJZ-JF quantities 0 SJZ-JF0 of 0. The BNDN000 is designed to accommodate DIN mount sockets. Made of durable extruded aluminum, the BNDN000 measures 0.3 (0.mm) in height and.37 (3mm) in width (DIN standard). Standard length is 3 (,000mm). Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 7

RJ Timers Signaling Lights Switches & Pilot Lights Specifications Model RJ RJ RJS RJV Number of Poles -pole -pole Contact Configuration SPDT DPDT DPDT bifurcated contacts DPDT (bifurcated), DPST-NO (bifurcated) Contact Material Silver-nickel alloy AgNi (gold clad) Degree of Protection IP0 Flux-tight structure Contact Resistance (initial value) 0 mω maximum Operating Time ms maximum (with diode: 0 ms maximum) Release Time 0 ms maximum (with diode: 0 ms maximum) Dielectric Strength Vibration Resistance Shock Resistance Electrical Life (rated load) Mechanical Life (no load) Operating Temperature 3 Operating Humidity Weight (approx.) Between contact and coil 000V AC, minute Between contacts of the same pole 000V AC, minute Between contacts of different poles 3000V AC, minute Operating extremes 0 to Hz, amplitude 0.7 mm Damage limits 0 to Hz, amplitude 0.7 mm Operating extremes NO contact: 00 m/s, NC contact: 00 m/s Damage limits 000 m/s AC load: 00,000 operations minimum (operation frequency 00 operations per hour) DC load: 00,000 operations minimum (operation frequency 00 operations per hour) AC coil: 30,000,000 operations minimum (operation frequency,000 operations per hour) DC coil: 0,000,000 operations minimum (operation frequency,000 operations per hour) g (blade type), 7g (PCB form C type), 6g (PCB form A type) AC load: 00,000 operations minimum (operation frequency,00 per hour) DC load: 00,000 operations minimum (operation frequency,00 per hour) AC load: 0 million operations minimum (operating frequency,000 operations per hour) DC load: 0 million operations minimum (operating frequency,000 operations per hour) 0 to +70 C (no freezing) to % RH (no condensation) g DPDT: 7g, DPST-NO: 6g Note: Above values are initial values.. Measured using V DC, A voltage drop method.. Measured at the rated voltage (at 0 C), excluding contact bounce time. 3. 00% rated voltage. Circuit Breakers Terminal Blocks Contactors www.idec.com

RJ Coil Ratings Coil Ratings AC DC Rated Voltage Blade & PCB Models Bifurcated Models Rated Voltage Blade Models PCB Models Bifurcated Models Coil Voltage Code Rated Current (ma) Coil Operating Characteristics ±% (at 0ºC) Resistance Without LED With LED (ohms)±0% Pickup Dropout Maximum 0Hz 60Hz 0Hz 60Hz (at 0ºC) Voltage Voltage Allowable Voltage 3 Power Consumption V A 3. 37. 7.. 3 0V A0. 7..7 7. 6,00 0.VA (60Hz) 0V A0.3 3.7.3 3.7,70 V A 7.3 7.0. 7. 6. 0% max 30% min 0% Approx. V A 3. 37. 7.. 3.VA (0Hz) 0V A0. 7..7 7. 6,00 0. to.va 0V A0.3 3.7.3 3.7,70 (60Hz) Coil Voltage Code Rated Current (ma) ±% (at 0ºC) Coil Resistance Without LED With LED (ohms)±0% Pickup (at 0ºC) Voltage Operating Characteristics Dropout Voltage Maximum Allowable Voltage 3 V D..0 7 V D..7,00 70% 70% max 0% min V D.0 0.7,30 00-0V D00.3 -.. -.7,70 60% V D 06 7. 6V D6.3 67. V D. 7 70% 70% max 0% min V D.,00 V D.0,30 00-0V D00.3 -.,70 60% V D 06 0 7. V D..0 7 V D..7,00 V D 0.7,30 70% max 0% min 00-0V D00.3-..-.7,70 60%. LED Indicator is only available on Blade or Bifurcated relays.. Operating characteristics are at 0ºC. 3. The maximum allowable voltage is the maximum value which can be applied to the relay coils. Contact Ratings Contact Ratings Blade Models PCB Models Model pole poles poles (bifurcated contacts) pole poles Standard Type High Capacity Type poles (bifurcated contacts) Allowable Contact Power Rated Load Allowable Allowable Contact Resistive Resistive Inductive Load Switching Switching Inductive Load Voltage Load Load cosø=0.3 L/R=7ms Current Voltage NO 3000VA 7VA 0V AC A 7.A 6A AC0V NC 3000VA 7VA 0V AC A 7.A 6A DC30V NO 000VA 000VA 0V AC A A A AC0V NC 000VA 000VA 0V AC A A A DC30V NO 0VA AC 00VA AC 0V AC A 0.A 0V AC A NC 30W DC W DC 30V DC A 0.A V DC NO 3000VA 7VA 0V AC A 7.A A 360W 0W 30V DC A 6A AC0V NC 3000VA 7VA 0V AC A 7.A DCV 6A 0W 0W 30V DC 6A 3A NO 000VA 000VA 0V AC 6A A 6A 0W 0W 30V DC 6A A AC0V NC 000VA 000VA 0V AC 6A A DCV A 0W 0W 30V DC A A NO 000VA 000VA 0V AC A A A 0W 0W 30V DC A A AC0V NC 000VA 000VA 0V AC A A DCV A 0W 60W 30V DC A A NO 0VA AC 00VA AC 0V AC A 0.A 0V AC A NC 30W DC W DC 30V DC A 0.A V DC Power Consumption 0.3W 0.3-0.6W 70% Approx. 0.3 to 0.6W Minimum Applicable Load DCV 00mA DCV 0mA V DC 00μA DCV 00mA DCV 00mA DCV 0mA V DC 00μA Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada

RJ Switches & Pilot Lights Signaling Lights Agency Ratings UL Voltage General Use Resistive RJ RJ RJ RJ NO NC NO NC NO NC NO NC 0V AC 6A 6A A A A A 30V DC A 6A A A A A CSA Voltage General Use Resistive Inductive RJ RJ RJ RJ RJ RJ RJ NO NC NO NC NO NC NO NC NO NC NO NC NO NC 0V AC A A A A A A 7.A 7.A A A 30V DC A 6A A A A A 6A 3A A A A A VDE Voltage Resistive AC-, DC-3* RJ RJ RJ RJ RJ NO NO NO NC NO NO 0V AC A A A A 6A 3A 30V DC A A A A.A A *According to the utilization categories of IEC607-- Timers Contactors Socket Specifications DIN Rail/ Panel Mount Finger-safe DIN Rail/Panel Mount PCB Mount Socket Terminal Electrical Rating Wire Size Torque SJS-0BW M3 screw with captive wire clamp 0V, A Maximum up to - # AWG 0.6 -.0N m (Maximum.N m) SJS-0BW M3 screw with captive wire clamp 0V, A Maximum up to - # AWG 0.6 -.0N m (Maximum.N m) SJS-07LW M3 screw with captive wire clamp, fingersafe 0V, A Maximum up to - # AWG 0.6 -.0N m (Maximum.N m) SJS-07LW M3 screw with captive wire clamp, fingersafe 0V, A Maximum up to - # AWG 0.6 -.0N m (Maximum.N m) SQV-07B M3 screw with box clamp, fingersafe 300V, A Maximum up to - # AWG.0N m Maximum SQV-07B M3 screw with box clamp, fingersafe 300V, 0A Maximum up to - # AWG.0N m Maximum SJS-6 PCB mount 0V, A SJS-6 PCB mount 0V, A SQV-63 PCB mount 300V, A SQV-63 PCB mount 300V, A Circuit Breakers Terminal Blocks 30 www.idec.com

RJ Electrical Life Curve (Resistive Load) ( 0,000 operations) RJ RJ High Capacity RJ 000 00 0 30V DC Resistive Load (NO Contact) 0V AC Resistive Load (NO contact) ( 0,000 operations) 000 00 0 30V DC Resistive Load (NO Contact) 0V AC Resistive Load (NO contact) 0. 0. 6 0. Maximum Switching Capacity (Resistive Load) RJ RJ High Capacity RJ 0 DC Resistive (NO Contact) AC Resistive (NO Contact) 0. 0 00 Load Voltage (V) 0 6 0 DC Resistive (NC Contact) DC Inductive (NO Contact) DC Inductive (NC Contact) AC Resistive DC Resistive (NO Contact) 0. 0 00 0 Load Voltage (V) AC Inductive ( 0,000 operations) 000 0 00 0 30V DC Resistive Load (NO Contact) AC Resistive (NO Contact) DC Resistive (NO Contact) 0. 0 00 Load Voltage (V) Operating Temperature and Coil Temperature Rise RJ (AC Coil, 60 Hz) RJ (AC Coil, 0 Hz) RJ (DC Coil) Temperature Rise (C) AC Coil (60 Hz) 30 0 0 00 0 0 Load Current A pole 70 60 0 0 30 No Load Current 0 0 0 0 0 30 0 0 60 70 Ambient Temperature (C) Temperature Rise (C) AC Coil (0 Hz) 30 0 0 00 0 0 Load Current A pole 70 60 0 0 30 No Load Current 0 0 0 0 0 30 0 0 60 70 Ambient Temperature (C) RJ (AC Coil, 60 Hz) RJ (AC Coil, 0 Hz) RJ (DC Coil) Temperature Rise (C) DC Coil 30 0 0 00 0 0 70 60 0 Load Current A poles 0 30 0 No Load Current 0 0 0 0 30 0 0 60 Ambient Temperature (C) 70 Temperature Rise (C) AC Coil (0 Hz) 30 0 0 00 0 0 70 Load Current A poles 60 0 0 30 No Load Current 0 0 0 0 0 30 0 0 60 70 Ambient Temperature (C) Temperature Rise (C) Temperature Rise (C) 0 0V AC Resistive Load (NO contact) DC Coil 30 0 0 00 0 0 70 60 Load Current A pole 0 0 30 0 No Load Current 0 0 0 0 30 0 0 60 70 Ambient Temperature (C) DC Coil 30 0 0 00 0 0 70 60 0 Load Current A poles 0 30 0 No Load Current 0 0 0 0 30 0 0 60 Ambient Temperature (C) 70 Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 3

RJ Switches & Pilot Lights Signaling Lights RJ (AC Coil, 60 Hz) RJ (AC Coil, 0 Hz) RJ (DC Coil) Temperature Rise ( C) 30 0 0 00 0 0 70 60 0 0 30 0 0 AC Coil (60 Hz) Load current A x poles No load current 0 0 0 30 0 0 60 70 0 0 0 30 0 0 60 70 Ambient Temperature ( C) Ambient Temperature ( C) The above temperature rise curves show characteristics when 00% the rated coil voltage is applied. The slanted dashed line indicates allowable temperature rise for the coil at different ambient temperatures. Temperature Rise ( C) 30 0 0 00 0 0 70 60 0 0 30 0 0 AC Coil (0 Hz) Load current A x poles No load current Temperature Rise ( C) 30 0 0 00 0 0 70 60 0 0 30 0 0 0 DC Coil Load current A x poles No load current 0 0 30 0 0 60 Ambient Temperature ( C) 70 Timers Contactors Internal Connection (View from Bottom) RJ-C-* Standard RJ-C/RJ-C-* Standard RJV-A-* (A) (A) () () 3() RJ-CL-* With LED Indicator (A) (A) () () 3() Coil voltage V AC/DC and below RJ-CD-* With Diode (A) (A) + () () 3() (A) RJ-CLD-* With LED Indicator and Diode (A) (A) + () () 3() Coil voltage V DC and below () () 3() (A) Coil voltage greater than V AC/DC (A) (A) + () () 3() Coil voltage greater than V DC (A) (A) () 7() 3() 6() Circuit Breakers Terminal Blocks () () RJ-CL/RJ-CL-* With LED Indicator (A) () 3() () (A) 7() 6() () Coil voltage V AC/DC and below RJ-CD-/ RJ-CD-* With Diode (A) (A) + () 3() () 7() 6() () (A) (A) (A) () 3() () 3() () 6() () (A) 7() 6() () Coil voltage greater than V AC/DC RJ-CLD/ RJ-CLD-* With LED Indicator and Diode (A) () 3() () + (A) 7() 6() () Coil voltage V DC and below (A) (A) () 3() () + 7() 6() () Coil voltage greater than V DC 3 www.idec.com

3 RJ Blade Relay (mm) RJS 7.0 ø. 3 hole PCB Relay (mm) RJV-C-*. max. (.3) 0.3.0 0.3. 3.. 0. 0. 0. 0. max. (.) RJV-CH-*/RJV-C-*. max. (.3) 0.3.0 0.3 RJV-C-*. max. (.3).0 0.3 0. 0. 0. 0. max. (.) 0.6 0.6 max. (.).0.0.7 3 max. (.7) 3 max. (.7) 0.6.0.0 3 max. (.7) (.6) (.) (.6) 0.. -ø.3 holes 0.0 -ø.3 holes.0 (.) 0.0. 3. 3. Dimensions (mm) 7..0 7. RJS/RJS ø. 3 hole 0.. max. (.3) 0.3.0.6 RJV-A-*. max. (.3) 0.3.0 0.3 3. 7. 3 6 0. 0. max. (.) RJV-AH-*/RJV-A-*. max. (.3) 0.3 0.3.0 0. 0. 0. 0.3 max. (.) max. (.) RJV-A-*. max. (.3).0 0.3 0. 0.6 max. (.) 7.0 6.0.7 0. 0. 3 max. (.7).6 All dimensions in mm. 3 max. (.7).0 3 max. (.7) 0.6.0.0 (.6) (.6) 3 max. (.7) -ø.3 holes (.) 0.0 6-ø.3 holes 7. 3. 7. (.) 0.0.0. Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 33

RJ Switches & Pilot Lights Standard DIN Rail Mount Sockets SJS-0BW. M3 Terminal Screws Dimensions con t (mm) SJS-0BW Signaling Lights.3 7 Terminal Blocks 6. M3 Terminal Screws 6.7.7.7.7.3 7 (A) (A) () (TOP VIEW) 3 () () (A) (A) () () 7 6 () () 3 () () (TOP VIEW) Finger-safe DIN Rail Mount Sockets SJS-07LW M3 Teminal Screws SJS-07LW M3 Terminal Screws ø.6 ø.6 Timers.7.3.. 7 3...7 ø3.7.3 7.. 3..7. ø3 (A) 3 () () (A) Contactors () 7 () () 6 (A) (TOP VIEW) () (A) (TOP VIEW) () () 3 () SQV-07B SQV-07B Circuit Breakers A A (TOP VIEW) A A (TOP VIEW) 3 www.idec.com

RJ PC Mount Sockets SJS-6 3..0 36..0.0 SQV-63 (.7) ±0. 7.0.0 ±0. ±0. ±0.. 6.0 ±0..0.0 ±0. -ø.6 holes Dimensions con t (mm) (Bottom View) 3 SJS-6.0.0 36. SQV-63 3..0 (.3) 7. ±0. 0.0 ±0..0 ±0. ±0..0 -ø.3 holes (Bottom View) 3 7 6 Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 3

RQ Switches & Pilot Lights Signaling Lights RQ Series PCB Relays IDEC RQ relays are low-profile, PCB relays in a compact package. Size equals value. RQ relays are small, yet maintain high contact ratings and long operational life. For larger power needs, a 6A model is also available. Key features: Low profile: x.7 x mm Contact rating: A (DPDT) and A (SPDT) High capacity model with 6A (SPDT) contact rating Operational life: 00K cycles at full resistive load 0 million cycles, no load LED/Diode Plug-in modules available with DIN rail socket UL Recognized File No. E0 R00660000 Part Number Selection Part Number Contact Model Pin Terminal Coil Voltage Code SPDT A Timers Basic RQV-CM-0 A, A, A30, D, D SPDT 6A Contactors HIgh Capacity (HC) RQV-CH-0 A, A, A30, D, D, D0 DPDT A Basic RQV-CN-0 A, A, A30, D, D, D0 Terminal Blocks Ordering Information When ordering, specify the Part No. and coil voltage code: (example) RQV-CM A Part No. Coil Voltage Code Circuit Breakers Coil Voltage Table Coil Voltage Code A A A30 D D D0 Coil Rating V AC 0-0V AC 0-0V AC V DC V DC 0V DC 36 www.idec.com

RQ Sockets Relays Finger-safe DIN Rail Mount PCB Mount RQ SQV-07B SQV-63* RQ RQ HC SQV-07B SQV-63*. *Comes with hold down spring. Comes with retaining clip and marking plate. Replacement Parts & Accessories Part Number Description Part Number Description SQZ-C Replacement retaining clip SQZ-LD Diode plug in modules for DIN socket SQZ-C63 Replacement hold-down spring for SQ PCB sockets SQZ-LR RC plug-in module (0-30V AC) for DIN socket SQZ-J pt jumper for DIN socket SQZ-P Replacement marking plate Accessories Item Appearance Use with Part No. Remarks Aluminum DIN Rail ( meter length) DIN Rail End Stop All DIN rail sockets BNDN000 DIN rail BNL. mm wide. Specifications Model (Contact) RQ RQ HC RQ No. of poles Contact Configuration SPDT SPDT DPDT Contact Rating A 6A A Contact Material Silver-Nickel alloy Contact Resistance Operating Time Release Time Dielectric Strength Vibration Resistance Shock Resistance Mechanical Life Electrical Life @ Full Rated Load Operating Temperature Operating Humidity Between contact & coil Between contacts Damage limits Operating extremes Damage limits Operating extremes 00mΩ max ms ms,000vac, minute,000vac, minute 0- Hz, amplitude.mm 0- Hz, amplitude.mm 00m/s min (0G),000m/s min (00G) 0,000,000 operations 00,000 operations -0 to º C to % RH Dimensions (H x W x D mm) x.7 x Weight (Approx.) g IDEC offers a low-profile DIN rail (BNDN000). The BNDN000 is designed to accommodate DIN mount sockets. Made of durable extruded aluminum, the BNDN000 measures 0.3 (0.mm) in height and.37 (3mm) in width (DIN standard). Standard length is 3 (,000mm). Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 37

RQ Switches & Pilot Lights Signaling Lights Coil Ratings Rated Voltage Nominal Current Coil Power Consumption 0HZ 60HZ Resistance 0HZ 60HZ Pickup Voltage Dropout Voltage Max Allowable Voltage V 33.3mA 360Ω DC V 6.7mA,0Ω 0.0W 0% Max % Min 30% 0V.mA 6,30Ω V.7mA.3mA 30Ω 0.7W 0.6W AC V 7.6mA 6.3mA,00Ω 0.W 0.73W 0% Max 30% Min 30% 30V 3.mA.7mA 3,00Ω 0.7W 0.63W Socket Specifications Relays Terminal Electrical Rating Wire Size Torque DIN Rail Sockets SQV-07B M3 screw with box clamp 300V, A Maximum up to - # AWG.0N m Maximum SQV-07B M3 screw with box clamp 300V, A Maximum up to - # AWG.0N m Maximum PCB Mount Socket SQV-63 PCB mount 300V, A SQV-63 PCB mount 300V, A Electrical Life Curves Maximum Switching Capacity RQ & RQ High Capacity RQ RQ, RQ High Capacity & RQ 7 0 7 0 300 00 Timers Circuit Breakers Operations Terminal Blocks (V) 0 6 0 Operations 0 6 0 Voltage of load 00 0 0 30 Contactors RQ RQ-HC 0 0 0 6 0 6 0 6 0 6 Internal Connection (View from Bottom) RQ RQ RQ HC 0 0 0. RQ RQ RQ-HC 0. 0. 0 0 NC NO NC C NO NC C C NC C NO NO 3 www.idec.com

RQ Dimensions (mm) RQ RQ/RQ HC SQ Socket Domensions SQV-07B SQV-07B A A A A (TOP VIEW) (TOP VIEW) SQV-63 PCB Pin Layout SQV-63 SQV-63 PCB Pin Layout SQV-63 Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 3

RH Switches & Pilot Lights Key features SPDT through PDT, 0A contacts Compact power type relays Miniature power relays with a large capacity 0A contact capacity Compact size saves space RH Series Compact Power Relays Terminal Blocks Contactors Timers Signaling Lights Contact SPDT DPDT 3PDT PDT Model Part Number Selection Blade Terminal Part Number PCB Terminal Standard RHB-U 0 RHV-U 0 With Indicator RHB-UL 0 With Check Button RHB-UC 0 With Indicator and Check Button RHB-ULC 0 Top Bracket Mounting RHB-UT 0 Coil Voltage Code (Standard Stock in bold) AC6V, ACV, ACV, AC0V, AC0V, AC0V, AC0V DC6V, DCV, DCV, DCV, DC0V With Diode (DC coil only) RHB-UD 0 RHV-UD 0 DC6V, DCV, DCV, DCV, DC0V With Indicator and Diode (DC coil only) RHB-ULD 0 DCV, DCV, DCV, DC0V Standard RHB-U 0 RHV-U 0 With Indicator RHB-UL 0 RHV-UL 0 With Check Button RHB-UC 0 With Indicator and Check Button RHB-ULC 0 Top Bracket Mounting RHB-UT 0 With Diode (DC coil only) RHB-UD 0 RHV-UD 0 With Indicator and Diode (DC coil only) RHB-ULD 0 RHV-ULD 0 Standard RH3B-U 0 RH3V-U 0 With Indicator RH3B-UL 0 RH3V-UL 0 With Check Button RH3B-UC 0 With Indicator and Check Button RH3B-ULC 0 Top Bracket Mounting RH3B-UT 0 With Diode (DC coil only) RH3B-UD 0 With Indicator and Diode (DC coil only) RH3B-ULD 0 Standard RHB-U 0 RHV-U 0 With Indicator RHB-UL 0 RHV-UL 0 With Check Button RHB-UC 0 With Indicator and Check Button RHB-ULC 0 Top Bracket Mounting RHB-UT 0 With Diode (DC coil only) RHB-UD 0 RHV-UD 0 With Indicator and Diode (DC coil only) RHB-ULD 0 AC6V, ACV, ACV, AC0-0V, AC0-0V DC6V, DCV, DCV, DCV, DC00-0V DC6V, DCV, DCV, DCV, DC00-0V AC6V, ACV, ACV, AC0V, AC0V, AC0V, AC0V DC6V, DCV, DCV, DCV, DC0V DC6V, DCV, DCV, DCV, DC0V AC6V, ACV, ACV, AC0V, AC0V, AC0V, AC0V DC6V, DCV, DCV, DCV, DC0V DC6V, DCV, DCV, DCV, DC0V Circuit Breakers PCB terminal relays are designed to mount directly to a circuit board without any socket. Ordering Information When ordering, specify the Part No. and coil voltage code: (example) RH3B-U AC0V Part No. Coil Voltage Code 0 www.idec.com

RH Sockets (for Blade Terminal Models) Relays Standard DIN Rail Mount Finger-safe DIN Rail Mount Through Panel Mount PCB Mount RHB SHB-0 SHB-OC SHB- SHB-6 RHB SHB-0 SHB-0C SHB- SHB-6 RH3B SH3B-0 SH3B-0C SH3B- SH3B-6 RHB SHB-0 SHB-0C SHB- SHB-6 Hold Down Springs & Clips Appearance Item Relay AC Coil Ratings Voltage (V) Pullover Wire Spring For DIN Mount Socket RHB SYS-0F RHB SYS-0F RH3B SH3B-0F RHB SHB-0F For Through Panel & PCB Mount Socket SYS-F Leaf Spring (side latch) RHB, RHB, RH3B, RHB SFA-0 3 SFA-30 3 Leaf Spring (top latch) RHB, RHB, RH3B, RHB SFA-0 3 SFA-30 3 Rated Current (ma) ±% at 0 C AC 0Hz AC 60Hz Coil Resistance (Ω) ±0% at 0 C SPDT DPDT 3PDT PDT SPDT DPDT 3PDT PDT SPDT DPDT 3PDT PDT 6 70 0 330 37 0 00 0 330 330. 6.. 6 6 6 7 00 0 6 6 3.3.3. 60. 37 0 70 3 3 3 03. 0.6..6....,00,00 0-0.- 0..0-. 0.6 6.. 7.. 6. 6. 0,00 7,360 0.7. 0.7. 7.7.. 0,00 7,360 0-0.7-..0-.6,0 0....3 7..3.3,00,0 DC Coil Ratings Voltage (V) Rated Current (ma) ±% at 0 C Coil Resistance (Ω) ±0% at 0 C SPDT DPDT 3PDT PDT SPDT DPDT 3PDT PDT 6 0 0 0 7 0 6 7 0 60 00 6 3 36. 60 6 70 60 00 3. 30 3,660,600,600,0 00-0.-.0,0 0. 3,00,600 7,30 Max. Continuous Applied Voltage 0% Operation Characteristics (against rated values at 0ºC) Pickup Voltage 0% maximum. DIN Rail mount socket comes with two horseshoe clips. Do not use unless you plan to insert pullover wire spring. Replacement horseshoe clip part number is Y77-0.. Must use horseshoe clip when mounting in DIN mount socket. Replacement horseshoe clip part number is Y77-0. 3. Two required per relay. Operation Characteristics (against rated values at 0ºC) Max. Continuous Applied Voltage 0% Dropout Voltage 0% minimum Pickup Voltage 0% maximum Dropout Voltage 30% minimum Standard coil voltages are in BOLD. Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada

RH Switches & Pilot Lights Signaling Lights Contact Ratings Model SPDT DPDT 3PDT PDT Continuous Current 0A Maximum Contact Capacity Allowable Contact Power Resistive Load 0VA 300W Inductive Load 0VA 0W Voltage (V) Rated Load Res. Load Ind. Load 0 AC 0A 7A 0 AC 7A.A 30 DC 0A 7A 0 AC 0A 7.A 0A 60VA 00VA 300W W 0 AC 7.A A 30 DC 0A 7.A Note: Inductive load for the rated load cos ø = 0.3, L/R = 7 ms TÜV Ratings Voltage RH RH RH3 RH 0V AC 0A 0A 7.A 7.A 30V DC 0A 0A 0A 0A AC: cos ø =.0, DC: L/R = 0 ms UL Ratings Voltage RH RH Resistive General Use Horsepower Rating RH3 RH RH RH RH3 RH RH RH 0V AC 0A 7.A 7.A 7A 6.A A /3 HP /3 HP 0V AC 0A 0A 7.A 7.A /6 HP /6 HP 30V DC 0A 0A 7A V DC 0A CSA Ratings Horsepower Voltage Resistive General Use Rating RH RH RH3 RH RH RH RH3 RH RH,, 3 0V AC 0A 0A 7.A 7A 7A 7A A /3 HP 0V AC 0A 0A 0A 0A 7.A 7.A 7.A /6 HP 30V DC 0A 0A 0A 0A 7A 7.A RH3 RH Timers Contactors Socket Specifications Sockets Terminal Electrical Rating Wire Size Torque DIN Rail Mount Sockets Finger-safe DIN Rail Mount Through Panel Mount Socket PCB Mount Socket SHB-0 SHB-0 SH3B-0 SHB-0 SHB-0C (Coil) M3 screws (contact) M3. screws with captive wire clamp 0V, 0A Maximum up to #AWG. - in lbs -. in lbs M3. screws with captive wire clamp 300V, 0A Maximum up to #AWG -. in lbs (coil) M3 screws (contact) M3. screws with captive wire clamp, fingersafe 0V, 0A Maximum up to #AWG. - in lbs -. in lbs SHB-0C SH3B-0C SHB-0C M3. screws with captive wire clamp, fingersafe 300V, 0A Maximum up to #AWG -. in lbs SHB- SHB- SH3B- Solder 300V, 0A SHB- SHB-6 PCB mount 0V, 0A SHB-6 SH3B-6 PCB mount 300V, 0A SHB-6 Terminal Blocks Accessories Item Appearance Use with Part No. Remarks Aluminum DIN Rail ( meter length) All DIN rail sockets BNDN000 The BNDN000 is designed to accommodate DIN mount sockets. Made of durable extruded aluminum, the BNDN000 measures 0.3 (0.mm) in height and.37 (3mm) in width (DIN standard). Standard length is 3 (,000mm). Circuit Breakers DIN Rail End Stop Replacement Hold-Down Spring Anchor DIN rail BNL. mm wide. DIN mount sockets and hold down springs. Y77-0 For use on DIN rail mount socket when using pullover wire hold down spring. pieces included with each socket. www.idec.com

RH Specifications Contact Material Silver cadmium oxide Contact Resistance 0mΩ maximum Minimum Applicable Load V DC, 30 ma; V DC, 00 ma (reference value) SPDT DPDT 0ms maximum Operating Time 3PDT PDT ms maximum SPDT DPDT 0ms maximum Release Time 3PDT PDT ms maximum SPDT AC:.VA (0Hz), VA (60Hz) DC: 0.W Power Consumption DPDT AC:.VA (0Hz),.VA (60Hz) DC: 0.W (approx.) 3PDT AC: VA (0Hz),.7VA (60Hz) DC:.W PDT AC:.VA (0Hz), VA (60Hz) DC:.W Insulation Resistance 00MΩ minimum (00V DC megger) Between live and dead parts:,000v AC, minute SPDT Between contact and coil:,000v AC, minute Between contacts of the same pole:,000v AC, minute Dielectric Strength 3 Between live and dead parts:,000v AC, minute DPDT Between contact and coil:,000v AC, minute 3PDT Between contacts of different poles:,000v AC, minute PDT Between contacts of the same pole:,000v AC, minute Operating Frequency Electrical:,00 operations/hour maximum Mechanical:,000 operations/hour maximum Vibration Resistance Damage limits: 0 to Hz, amplitude 0. mm Operating extremes: 0 to Hz, amplitude 0. mm Damage limits:,000m/s (00G) Shock Resistance Operating extremes: 00m/s (0G - SPDT, DPDT) 00m/s (0G - 3PDT, PDT) Mechanical Life 0,000,000 operations minimum DPDT 00,000 operations minimum (0V AC, 0A) Electrical Life SPDT 3PDT 00,000 operations minimum (0V AC, 0A) PDT Operating Temperature Operating Humidity Weight (approx.) SPDT DPDT 3PDT PDT to +70 C (no freezing) to % RH (no condensation) SPDT: g, DPDT: 37g, 3PDT: 0g, PDT: 7g Note: Above values are initial values.. Measured using V DC, A voltage drop method. Measured at the rated voltage (at 0 C), excluding contact bouncing Release time of relays with diode: 0 ms maximum 3. Relays with indicator or diode: 000V AC, minute. For use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve. The operating temperature range of relays with indicator or diode is to +0 C. Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 3

RH Switches & Pilot Lights Electrical Life Curves AC Load 000 (RH) 00 0V AC resistive Characteristics (Reference Data) DC Load 000 (RH) 00 Signaling Lights Life ( 0,000 operations) 00 0 0 0V AC inductive 0V AC inductive 0V AC resistive Life ( 0,000 operations) 00 0 0 00V DC resistive 30V DC inductive 00V DC inductive 30V DC resistive 0 3 6 7 0 0 3 6 7 0 (RH) 000 Life ( 0,000 operations) 00 00 0 0V AC resistive 0V AC inductive 0V AC resistive 0V AC inductive (RH) 000 00 00 0 Life ( 0,000 operations) 00V DC resistive 00V DC inductive 30V DC resistive 30V DC inductive 0 0 Timers 0 3 6 7 0 0 3 6 7 0 (RH3/RH) 000 (RH3/RH) 000 00 0V AC resistive 00 30V DC resistive Contactors Life ( 0,000 operations) 00 0 Life ( 0,000 operations) 00 0 30V DC inductive Terminal Blocks 0 0 0V AC inductive Maximum Switching Capacity (RH) 0.0.0 0V AC resistive 0V AC inductive 3 6 7 0 AC resistive AC inductive 0 0 (RH/RH3/RH) 0.0.0 00V DC resistive 00V DC inductive 3 6 7 0 AC resistive AC inductive.0 DC resistive.0 DC inductive DC resistive Circuit Breakers 0. 0. DC inductive 0 0 00 00 300 Load Voltage (V) 0. 0. 0 0 00 00 300 Load Voltage (V) www.idec.com

RH Continuous Load Current vs. Operating Temperature Curve (Basic Type, With Check Button, and Top Bracket Mounting Type) (RH) Operating Temperature ( C) 00 0 0 70 60 0 0 30 0 0 0 Note: The rated voltage is applied to the coil. AC Coil DC Coil 3 6 7 0 (RH) Operating Temperature ( C) 00 0 0 70 60 0 0 30 0 0 0 Note: The rated voltage is applied to the coil. DC Coil AC Coil 3 6 7 0 (RH3/RH) Internal Connection (View from Bottom) Basic Type SPDT DPDT 3PDT PDT With Check Button 6 0 3 7 3 ( ) ( + ) With Indicator (-L type) SPDT 3PDT PDT DPDT Below 00V AC/DC 00V AC/DC and over 3 ( ) ( + ) 3 ( ) ( + ) 6 0 3( ) ( + ) 6 0 3 ( ) ( + ) 6 0 3 7 3( ) ( + ) 6 0 3 7 3 ( ) ( + ) With Diode (-D type) SPDT DPDT 3PDT PDT 3 ( ) ( + ) 3 ( ) ( + ) 6 0 3 ( ) ( + ) 6 0 Below V AC/ DC V AC/ DC and over 3 7 3 ( ) ( + ) Operating Temperature ( C) 00 0 0 70 60 0 0 30 0 0 0 Note: The rated voltage is applied to the coil. AC/DC Coil 3 6 7 0 Front Pushbutton Contacts can be operated by pressing the check button. 3( ) ( + ) 3( ) ( + ) When the relay is energized, the indicator goes on. Relay coils less than 00V DC do not contain a protection diode (except DPDT). Relay coils below 00V use LED indicator, coils above 00V use neon lamp indicator. LED color of DPDT model is green Contains a diode to absorb the back emf generated when the coil is de-energized. The release time is slightly longer. Available for DC coil only. Diode Characteristics Reverse withstand voltage:,000v Forward current: A Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada

RH Switches & Pilot Lights With Indicator LED & Diode (-LD type) Below 00V DC SPDT 3PDT PDT DPDT 3 ( ) ( + ) Below V AC/ DC 3( ) ( + ) Contains an LED indicator and a surge absorber, and has the same height as the basic type. Signaling Lights 00V DC and over 3( ) ( + ) V AC/ DC and over 3 ( ) ( + ) LED color of DPDT model is green. Dimensions (mm) RHB-U/RHB-UL/RHB-UD/RHB-ULD RHB-U/RHB-UL/RHB-UD/RHB-ULD RH3B-U/RH3B-UL/RH3B-UD/RH3B-ULD Total length from panel surface including relay socket SHB-0: 6. (63.) max., SHB-: 3.6 (.6) max. Dimensions in the ( ) include a hold-down spring. Total length from panel surface including relay socket SHB-0: 6. (63.) max., SHB-: 3.6 (.6) max. Dimensions in the ( ) include a hold-down spring. Total length from panel surface including relay socket SH3B-0: 6. (63.) max., SH3B-: 3.6 (.6) max. Dimensions in the ( ) include a hold-down spring. ø.6 hole.7 ø.6 hole.7 ø.6 hole.7 0. 3 7. 0. 7. 3 Timers 3.6 max.. 6. 3.6 max. 6. 0. 6 0 3 7. 3.6 max. 6. 3 RHB-U/RHB-UL/RHB-UD/RHB-ULD RHB-UT RHB-UT Total length from panel surface including relay socket SHB-0: 6. (63.) max., SHB-: 3.6 (.6) max..7 Contactors.7 Dimensions in the ( ) include a hold-down spring. 3. 3 ø.6 hole 0..7. 3 7. 3. 3 ø.6 hole 0..7 0. 7. 3 ø.6 hole 3... 3.6 max. 6. 6.6 3..7 7. 3. 3.6 max. 6. 0. 6 7 0 7. 3 Terminal Blocks RH3B-UT 3.6 max. 6. RHB-UT 0 0 0 Circuit Breakers 3. 3.7 0 0 3. ø.6 hole. 3. 3.6 max. 6. 0. 7..7. 6 0 3 3 ø.6 hole 3.6 max. 6. max..7 0. 7..7. 3. 3 6 7 0 3. 6 www.idec.com

RH RHV-U/RHV-UD 0.. 0. 3.6 max..6 RH3V-U/RH3V-UL/RH3V-D 0. 0. 3.6 max..6 3 7. 6 0 3 Standard DIN Rail Mount Sockets SHB-0 67. 7 6 0. SH3B-0 67. 3 36 0 M3 Terminal Screw M3. Terminal Screw. 7 M3. Terminal Screw 7 3.. 3 7. max. 7. DIN Rail (BNDN). max. -ø holes 7.. -ø. holes 0 0 7. (For terminals,, and ) 3.. -ø. Mounting Holes (or M Tapped Holes) 6 DIN Rail (BNDN). min.. min. max. ø3.6 min. 7. max.. max. Dimensions con t (mm) 3-ø. holes 6.6 7...7 3..7 (Top View) ø3. min. (For terminals 3 and ) -ø. Mounting Holes (or M Tapped Holes) 36. max.. min. ø3.6 min. 3 6 0 3 (Top View) RHV-U/RHV-UL/RHV-UD 0. 0. 3.6 max..6 0. 3 RHV-U/RHV-UL/RHV-UD SHB-0 67. 0. 3 6 7 0 3 0. 3.6 max..6 6 30 SHB-0 67. 6 0. M3. Terminal Screw. 7 M3. Terminal Screw 7 3.. 3.. 7. 7. DIN Rail (BNDN) -ø. holes 7. 7. max. 6 7. -ø. holes 30 0 -ø. Mounting Holes (or M Tapped Holes). max.. min. DIN Rail (BNDN) 6 ø3.6 min. 0. -ø. Mounting Holes (or M Tapped Holes). max.. min. 7. max. ø3.6 min. 7. 3..7 7. 3..7 3 (Top View) 7 3 6 0 3 (Top View) Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 7

RH Switches & Pilot Lights Finger-safe DIN Rail Mount Sockets SHB-0C 7 7 M3. Terminal Screw ø. 36 DIN Rail (BNDN) -ø. Mounting Holes (or M Tapped Holes) Dimensions con t (mm) SHB-0C 7 M3. Terminal Screw ø. 36 DIN Rail (BNDN) -ø. Mounting Holes (or M Tapped Holes) Signaling Lights 6.7 6 0 SH3B-0C M3 Terminal Screw.7. 6 Ring terminals cannot be used. 3 (Top View).7 6 6 30 SHB-0C.7. 6 Ring terminals cannot be used. 3 (Top View) Timers Contactors Circuit Breakers Terminal Blocks 6.7 3 36 0 7 M3. Terminal Screw ø. 36.7. DIN Rail (BNDN) -ø. Mounting Holes (or M Tapped Holes) 36 Ring terminals cannot be used. 6 3 0 (Top View).7 6 6 0 7 ø. When using BAA/BAP: 33.7. DIN Rail (BAA/BAP) -ø. Mounting Holes (or M Tapped Holes) 6 Ring type crimping terminals cannot be used. 7 6 3 3 0 (Top View) Through Panel Mount Socket SHB- SHB- SH3B- SHB- www.idec.com

RH PCB Mount Sockets SHB-6 3. SH3B-6 3 36 30.. 3 3 0.3 0.3.. 3 (Bottom View) 6 0 3 (Bottom View) 3-ø. holes.7 6.. 3 min.* * 36 min. when using hold-down springs.7 3 min.* * 36 min. when using hold-down springs 7.3. 6.6 6.6. Dimensions con t (mm) SHB-6 6. min.. -ø holes (Tolerance ±0.) 36 min..3 0 0 -ø. holes (Tolerance 0.). SHB-6 3 3. 3 3 0.3 0.3.. 3 (Bottom View) 6 3 7 0 3 (Bottom View) * 36 min. when using hold-down springs.7..6. min.* 6.6 * 3 min. when using hold-down springs 3 min.*..7 6. 6.6 6.6 min. 3.3 0 0 0. 0. min. -ø. holes (Tolerance 0.) -ø. holes (Tolerance 0.) Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada

RR Switches & Pilot Lights RR Series Power Relays Key features: SPDT through 3PDT, 0A contacts Midget power type relays Available in pin and blade terminal styles. Options include an indicator, check button for test operations and side flange. DIN rail, surface and panel mount sockets are available for a wide a variety of mounting applications. Signaling Lights Timers Part Number Selection Part Number Contact Model Pin Terminal Blade Terminal* SPDT Standard RRBA-U 0 With Indicator RRBA-UL 0 With Check Button RRBA-UC 0 With Indicator and Check Button RRBA-ULC 0 Side Flange Model RRBA-US 0 DPDT Standard RRP-U 0 RRBA-U 0 With Indicator RRP-UL 0 RRBA-UL 0 With Check Button RRP-UC 0 RRBA-UC 0 With Indicator and Check Button RRP-ULC 0 RRBA-ULC 0 Side Flange Model RRBA-US 0 3PDT Standard RR3PA-U 0 RR3B-U 0 With Indicator RR3PA-UL 0 RR3B-UL 0 With Check Button RR3PA-UC 0 RR3B-UC 0 With Indicator and Check Button RR3PA-ULC 0 RR3B-ULC 0 Coil Voltage Code (Standard Stock Items in Bold) AC6V, ACV, ACV, AC0V, AC0V, AC0V, DC6V, DCV, DCV, DCV, DC0V Side Flange Model RR3B-US 0 Contactors *Blade type not TUV tested or CE marked. Side flange model mounts directly to panel with no socket required. Sockets Relays Standard DIN Rail Mount Finger-safe DIN Rail Mount Through Panel Mount Ordering Information When ordering, specify the Part No. and coil voltage code: (example) RR3B-U AC0V Part No. Coil Voltage Code Terminal Blocks RRP RR3PA RRBA RRBA RR3B SRP-0 SRP-06 SR3P-0 SR3P-06 SRP-0C SR3P-0C SRP- SR3P- SR3B-0 SR3B- Circuit Breakers All DIN rail mount sockets shown above can be mounted using DIN rail BNDN000. 0 www.idec.com

RR Hold Down Springs & Clips Appearance Description Relay Pullover Wire Spring Leaf Spring (side latch) RRP RR3PA RRBA, RRBA, RR3B For DIN Mount Socket SRB-0F SR3B-0F SR3B-0F RRP, RR3PA SFA-03 For Through Panel & PCB Mount Socket SR3P-0F SR3B-0F Accessories Item Appearance Use with Part No. Remarks Aluminum DIN Rail ( meter length) DIN Rail End Stop Replacement Hold-Down Spring Anchor All DIN rail sockets BNDN000 DIN rail BNL. mm wide. Horseshoe clip for sockets SR3B-0, SRP-06, SR3P-06 Chair clip for sockets SRP-0(C), SR3P-0(C) Y77-0 Y703-0 The BNDN000 is designed to accommodate DIN mount sockets. Made of durable extruded aluminum, the BNDN000 measures 0.3 (0.mm) in height and.37 (3mm) in width (DIN standard). Standard length is 3 (,000mm). For use on DIN rail mount socket when using pullover wire hold down spring. pieces included with each socket. Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada

RR Timers Signaling Lights Switches & Pilot Lights Specifications Contact Material Silver Contact Resistance 30 mω maximum Minimum Applicable Load V DC, 0 ma Operating Time ms maximum Release Time ms maximum Power Consumption (approx.) AC: 3 VA (0 Hz),. VA (60 Hz) DC:.W Insulation Resistance 00 MΩ minimum (00V DC megger) Between live and dead parts: 00V AC, minute Pin Terminal Between contact and coil: 00V AC, minute Between contacts of different poles: 00V AC, minute Dielectric Between contacts of the same pole: 000V AC, minute Strength Between live and dead parts: 000V AC, minute Blade Terminal Between contact and coil: 000V AC, minute Between contacts of different poles: 000V AC, minute Between contacts of the same pole: 000V AC, minute Operating Frequency Electrical: 00 operations/h maximum Mechanical:,000 operations/h maximum Vibration Resistance Damage limits: 0 to Hz, amplitude 0. mm Operating extremes: 0 to Hz, amplitude 0. mm Shock Resistance Damage limits: 000 m/s (00g) Operating extremes: 00 m/s (0G) Mechanical Life 0,000,000 operations Electrical Life 00,000 operations (0V AC, A) Operating Temperature 3 to +0 C (no freezing) Operating Humidity to % RH (no condensation) Weight (approx.) (Standard type) RRP: 0g, RR3PA: 6g, RRBA/RRBA/RR3B: g. Measured using V DC, A voltage drop method. Measured at the rated voltage (at 0 C), excluding contact bouncing 3. For use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve. Contactors Terminal Blocks Coil Ratings Rated Voltage (V) AC (0/60 Hz) DC Rated Current (ma) ±% (at 0 C) 0 Hz 60 Hz Coil Resistance (Ω) ±0% (at 0 C) 6 0 0. 0 0 7 0 7 3,60 0 0.,00 0. 0.,330 6 0 0 00 60 00 30,600 0 3,60 Operating Characteristics (values at 0 C) Maximum Continuous Pickup Voltage Dropout Voltage Applied Voltage 0% 0% maximum 30% minimum 0% 0% maximum 0% minimum Circuit Breakers www.idec.com

RR Contact Ratings Continuous Current 0A Maximum Contact Capacity Allowable Contact Power Resistive Load 60VA AC 300W DC Inductive Load 00VA AC 0W DC Note: Inductive load for the rated load cos ø = 0.3, L/R = 7 ms TÜV Ratings Voltage 0V AC 30V DC 0A 0A Rated Load Voltage (V) Res. Load Ind. Load 0 AC 0A 7.A 0 AC 7.A A 30 DC 0A A AC: cos ø =.0, DC: L/R = 0 ms UL Ratings Voltage Resistive General use Horse Power Rating 0V AC 0A 7A /3 HP 0V AC 0A 7.A / HP 30V DC 0A 7A CSA Ratings Voltage Resistive General use 0V AC 0A 7A 0V AC 0A 7.A 00V DC 0.A 30V DC 0A 7.A Socket Specifications Relays Terminal Electrical Rating Wire Size Torque SRP-0 M3 screw with captive wire clamp 300V, 0A Maximum - # AWG -.in lbs SRP-0C M3 screw with captive wire clamp, fingersafe 300V, 0A Maximum - # AWG -.in lbs SRP-06 M3 screw with captive wire clamp 300V, 0A Maximum - # AWG -.in lbs DIN Rail Sockets SR3P-0 M3 screw with captive wire clamp 300V, 0A Maximum - # AWG -.in lbs SR3P-0C M3 screw with captive wire clamp, fingersafe 300V, 0A Maximum - # AWG -.in lbs SR3P-06 M3 screw with captive wire clamp 300V, 0A Maximum - # AWG -.in lbs SR3B-0 M3 screw with captive wire clamp 300V, A (0A)* (*CSA rating) Maximum - # AWG -.in lbs Through SRP- Solder 300V, 0A Panel Mount SR3P- Solder 300V, 0A Sockets SR3B- Solder 300V, 0A Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 3

RR Switches & Pilot Lights Signaling Lights Electrical Life Curves AC Load Life ( 0,000 operations) 000 00 00 0V AC resistive 0 0V AC resistive 0V AC inductive 0 0V AC inductive Maximum Switching Capacity 0 0. 0. 0 Characteristics (Reference Data) DC Load Life ( 0,000 operations) 000 00 00 0 00V DC resistive 00V DC inductive 0 30V DC resistive 30V DC inductive 0 0.0 0.0 0. 0. 0 Continuous Load Current vs. Operating Temperature Curve (Standard Type, With Check Button, and Side Flange Type) 0.0.0.0 0. DC resistive DC inductive AC resistive AC inductive Operating Temperature (C) Timers Contactors Circuit Breakers Terminal Blocks 00 0 0 70 60 0 0 30 AC Coil DC Coil 0 0 0 30 0 00 00 300 Load Voltage (V) 0 3 6 7 0 Internal Connection (View from Bottom) Standard Type RRP-U RR3PA-U RRBA-U RRBA-U RR3B-U With Check Button Front Pushbutton Contacts can be operated by pressing the check button. With Indicator (-UL type) RRP RR3PA RRBA RRBA RR3B www.idec.com

RR Coil Below 00V AC/DC Coil 00V AC/DC and over RRP-U/RRP-UL Total length from panel surface including relay socket SRP-0:. (7.) max., SRP-: 63 (6) max.. max. RRBA-U/RRBA-UL/RRBA-U RRBA-UL/RR3B-U/RR3B-UL 7. max. 7.3.7. 3 3.0 ø.0 oblong hole Total length from panel surface including relay socket SR3B-0: 73 (76) max., SR3B-: 6 (60) max. 0. Standard DIN Rail Mount Sockets SRP-0 3 36 M3. Terminal Screw 33 ø ø. hole 3 6. 0. A 3 6 7.6 3.6 Dimensions in the ( ) include a hold-down spring. 3 6 7 36 Dimensions in the ( ) include a hold-down spring. DIN Rail (BNDN) 7. max. B 36 -ø. Mounting Holes (or M Tapped Holes). max. min. ø3.6 min. Dimensions (mm) RR3PA-U/RR3PA-UL RRBA-US/RRBA-US/RR3B-US 6.0 6 3 7 (Top View). SRP-06 60 0 33 Total length from panel surface including relay socket SR3P-0:. (7.) max., SR3P-: 63 (6) max. 63. 73.. max. 7.3 7. max. 6. M3. Terminal Screw ø. hole ø 0..7.... 3 3.0 ø.0 oblong hole A 3 6 7 DIN Rail (BNDN) 36 3 When the relay is energized, the indicator goes on. An LED protection diode is not contained in relay coils below 00V DC. Coils below 00V use LED indicator while coils above 00V use neon lamp indicator. 6 3.6 0 3.6 Dimensions in the ( ) include a hold-down spring. B 36 7 -ø. Mounting Holes 63. -ø. Mounting Holes 6 3 (or M Tapped Holes) 33. max. min. 7. max. ø3.6 min. 7 (Top View) Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada

RR Switches & Pilot Lights Standard DIN Rail Mount Sockets SR3P-0 M3. Terminal Screw 3 DIN Rail (BNDN) -ø. Mounting Hole (or M Tapped Holes) 7 6 SR3P-06 M3. Terminal Screw. DIN Rail (BNDN) -ø. Mounting Holes (or M Tapped Holes) 7 6 Signaling Lights 3 3 SR3B-0 36 ø. hole 33 ø7 M3. Terminal Screw. 6. 0. 7. max. 3. max. min. ø3.6 min. 3. DIN Rail (BNDN) -ø. Mounting Holes (or M Tapped Holes) 3 0 (Top View) 6 3 60 33 ø. hole ø7 33. max. min. 7. max. ø3.6 min. 0 3 (Top View) 76 37 3 6. 37. max.. min. 7. max. ø3.6 min. B A 7 (Top View) Finger-safe DIN Rail Mount Sockets SRP-0C SR3P-0C Timers 36 7 ø 36. DIN Rail (BNDN) -ø. Mounting Holes (or M Tapped Holes) 6 3 7 ø 36. DIN Rail (BNDN) -ø. Mounting Holes (or M Tapped Holes) 7 6. ø. hole. 30 Ring type crimping terminals cannot be used. 7 (Top View). 3 ø. hole. 30 3 Ring type crimping terminals cannot be used. 3 0 (Top View) Contactors Through Panel Mount Socket SRP- SR3P-. 6 Panel Surfarface -ø3. Mounting Holes (or M3 Tapped Holes). 6 Panel Surfarface -ø3. Mounting Holes (or M3 Tapped Holes) 0 3 ø 3 6 7 ø30 3 0 3 ø 6 7 3 0 ø30 3 Terminal Blocks SR3B- 3. 0. (Bottom View) 3. 0. (Bottom View) 3 7. max. 6.7 3.* -ø. Mounting Holes (M Tapped Holes). 3 3 0.3 3 3 6 7 A B. min. 3. 3 Circuit Breakers 3. 3 3 6. (Bottom View) *When two or more sockets are mounted side by side: L = 3 (N ) + 3. N: No. of sockets mounted (Tolerance 0.3) 6 www.idec.com

RU RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator No internal wires, lead-free construction Cadmium-free contacts Mechanical flag indicator Manual latching lever with color coding for AC or DC coil Snap-on yellow marking plate; optional marking plates are available in four other colors Maximum contact ratings: 0A (RU), 6A (RU), 3A (RU) UL Recognized, CSA Certified, EN Compliant With Latching or Momentary Lever Mechanical Indicator* The contact position can be confirmed through the five small windows. Marking Plate Standard yellow marking plate is easily replaced with optional marking plates in four colors for easy identification of relays. LED Indicator* Non-polarized green LED indicator is standard provision for plug-in terminal, latching lever types Standard (without lever) Mechanical Indicator* Marking Plate LED Indicator* Non-polarized green LED indicator is standard provision for plug-in terminal types. *Not available on PCB type. EN60- AC/DC Color Marking For identification of AC or DC coils. AC coil: Yellow DC coil: Blue AC Coil DC Coil Latching and Momentary Lever Using the lever, operation can be checked without energizing the coil. The lever is color coded for AC and DC coils. Latching Momentary AC coil: Orange Red DC coil: Green Blue In Normal Operation Note: Turn off the power to the relay coil when using the latching lever. After checking the operation, return the latching lever in the normal position. Coil Voltage Tape Color V AC White 00 to 0V AC Clear 0 to 0V AC Blue 00 to 0V AC Black 0 to 0V AC Red V DC Green 6V DC V DC V DC Voltage marking on yellow tape 0V DC Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 7

RU Timers Signaling Lights Switches & Pilot Lights Part Number Selection Part Number Contact Model Standard With Latching Lever With Momentary Lever DPDT (0A) Standard RUS-C-0 RUS-0 RUS-M-0 PDT (6A) PDT Bifurcated (3A) With RC (AC coil only) RUS-CR-0 RUS-R-0 RUS-MR-0 A0, A0 Coil Voltage Code (Standard Stock in bold) A, A0, A0 D6, D, D, D, D0 With diode (DC coil only) RUS-CD-0 RUS-D-0 RUS-MD-0 D6, D, D, D, D0 PCB RUV-NF-0 Standard RUS-C-0 RUS-0 RUS-M-0 With RC (AC coil only) RUS-CR-0 RUS-R-0 RUS-MR-0 A0, A0 A, A0, A0 D6, D, D, D, D0 A, A0, A0 D6, D, D, D, D0 With diode (DC coil only) RUS-CD-0 RUS-D-0 RUS-MD-0 D6, D, D, D, D0 PCB RUV-NF-0 Standard RUS-C-0 RUS-0 RUS-M-0 With RC (AC coil only) RUS-CR-0 RUS-R-0 RUS-MR-0 A0, A0 A, A0, A0 D6, D, D, D, D0 A, A0, A0 D6, D, D, D, D0 With diode (DC coil only) RUS-CD-0 RUS-D-0 RUS-MD-0 D6, D, D, D, D0 PCB RUV-NF-0 A, A0, A0 D6, D, D, D, D0. Plug-in terminal models have an LED indicator and a mechanical indicator as standard.. PCB models do not have an LED indicator or a mechanical indicator. Ordering Information When ordering, specify the Part No. and coil voltage code: (example) RUS-C A0 Coil Voltage Table Coil Voltage Code A A0 A0 D6 D D D D0 Coil Rating V AC 0-0V AC 0-0V AC 6V DC V DC V DC V DC 0V DC Part No. Coil Voltage Code Sockets Contactors Relays Spring Clamp DIN Rail Mount Standard DIN Rail Mount Finger-safe DIN Rail Mount RUS (DPDT) SUS-L SMS-0 SMS-0C RUS (PDT) RUS (PDT) SUS-L SYS-0 SYS-0C Panel Mount SYS- PCB Mount SMS-6 SMS-6 SYS-6 SYS-6 Circuit Breakers Terminal Blocks www.idec.com

RU Hold Down Springs & Clips Appearance Item Relay Accessories Pullover Wire Spring Leaf Spring (side latch) Leaf Spring (top latch) RUS/RUS/ RUS RUS/RUS/ RUS RUS/RUS/ RUS For DIN Mount Socket SYS-0F SFA-0* SFA-0* Name Part Number Color Code * Marking Plate RUZ-P* A (orange), G (green), S (blue), W (white), Y (yellow) For Through Panel & PCB Mount Socket SYS-F SFA-30* SFA-30* Specify a color code when ordering. The marking plate can be removed from the relay by inserting a flat screwdriver under the marking plate. Specifications Model (Contact) RU (DPDT) RU (PDT) RU (PDT-bifurcated) Contact Material Silver alloy Silver (gold clad) Silver-nickel (gold clad) Contact Resistance 0 mω maximum Minimum Applicable Load Operating Time 3 Release Time 3 V DC, ma (reference value) V DC, ma V DC, 0. ma 0 ms maximum 0 ms maximum Power Consumption AC:. to.va (0 Hz), 0. to.va (60 Hz) DC: 0. to.0w Insulation Resistance 00MΩ minimum (00V DC megger) Between contact and coil: 00V AC, minute Between contacts of different poles: Dielectric Strength 00V AC, minute 000V AC, minute Between contacts of the same pole: 000V AC, minute Operating Frequency Electrical: 00 operations/h maximum Mechanical:,000 operations/h maximum Vibration Resistance Damage limits: 0 to Hz, amplitude 0. mm Operating extremes: 0 to Hz, amplitude 0. mm Shock Resistance Damage limits: 000 m/s (00G) Operating extremes: 0 m/s (G) Mechanical Life AC: 0,000,000 operations DC: 00,000,000 operations 0,000,000 operations Electrical Life See table on page 6 Operating Temperature Operating Humidity Weight PCB model: to +70 C (no freezing) Blade model: to +60 C (no freezing) to % RH (no condensation) Approx. 3g. Measured using V DC, A voltage drop method. Measured at operating frequency of 0 operations/min (failure rate level P, reference value) 3. Measured at the rated voltage (at 0 C), excluding contact bouncing; Release time of AC relays with RC: ms maximum Release time of DC relays with diode: 0 ms maximum Note: Order pieces for each relay. Contact Load and Electrical Life (at ambient temperature 0 C). Measured at the rated voltage. Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada

RU Switches & Pilot Lights Accessories Item Appearance Use with Part No. Remarks Aluminum DIN Rail ( meter length) All DIN rail sockets BNDN000 The BNDN000 is designed to accommodate DIN mount sockets. Made of durable extruded aluminum, the BNDN000 measures 0.3 (0.mm) in height and.37 (3mm) in width (DIN standard). Standard length is 3 (,000mm). DIN Rail End Stop DIN rail BNL. mm wide. Signaling Lights Timers Replacement Hold-Down Spring Anchor Coil Ratings Rated Voltage (V) AC (0/60 Hz) DC Coil Voltage Code Horseshoe clip for DIN rail sockets Rated Current (ma) ±% (at 0 C) Coil Resistance (Ω) ±0% (at 0 C) 0 Hz 60 Hz A.3. 6 0-0 A0.-0.0 7.-.,0 0-0 A0.-.0 3.6-.,30 6 D6 0 D 0 60 D.7 60 D,60 0 D0.,00. The rated current includes the current of the LED indicator. Y77-0 For use on DIN rail mount socket when using pullover wire hold down spring. pieces included with each socket. Maximum Continuous Applied Voltage Operating Characteristics (values at 0 C) Pickup Voltage Dropout Voltage 0% 0% maximum 30% minimum 0% 0% maximum 0% minimum Surge Suppressor Ratings UL and c-ul Ratings Contactors Model AC Coil With RC DC Coil With Diode Ratings RC series circuit R: 0 kω, C: 0.033 µf Diode reverse voltage: 000V Diode forward current: A Voltage Resistive General Use Horse Power Rating RU RU RU RU RU RU RU RU RU 0V AC 0A 3A 6A /0HP 30V DC 0A 6A 3A Terminal Blocks Contact Ratings Contact DPDT PDT Continuous Current 0A 6A Maximum Contact Capacity Allowable Contact Power Voltage Rated Load Resistive Load Inductive Load (V) Res. Load Ind. Load 00VA AC 0VA AC 0 AC 0A A 300W DC 0W DC 30 DC 0A A 00VA AC 600VA AC 0 AC 6A 0.A 0W DC 0W DC 30 DC 6A.A CSA Ratings Resistive Voltage RU 0V AC 3A 30V DC 3A TÜV Ratings Voltage Resistive Inductive RU RU RU RU RU RU 0V AC 0A 6A 3A A 0.A 0.A 30V DC 0A 6A 3A A.A.A PDT bifurcated 3A 70VA AC 00VA AC 0 AC 3A 0.A 0W DC W DC 30 DC 3A.A Circuit Breakers. On PDT relays, the maximum allowable total current of neighboring two poles is 6A. At the rated load, make sure that the total current of neighboring two poles does not exceed 6A (3A + 3A = 6A).. Inductive load for the rated load cos ø = 0.3, L/R = 7 ms 60 www.idec.com

RU Socket Specifications Sockets Terminal Electrical Rating Wire Size Torque SUS-L Spring clamp terminals 0V/0A -6 AWG SUS-L Spring clamp terminals 0V/6A (using RU), 0A (using RU) -6 AWG DIN Rail Mount SMS-0 M3 screw with captive wire clamp 300V, 0A Maximum up to #AWG. - in lbs Sockets SMS-0C M3 screw with captive wire clamp, fingersafe 300V, 0A Maximum up to #AWG. - in lbs SYS-0 M3 screw with captive wire clamp 300V, 7A (using RU), 0A (using RU) Maximum up to #AWG. - in lbs SYS-0C M3 screw with captive wire clamp, fingersafe 300V, 7A (using RU), 0A (using RU) Maximum up to #AWG. - in lbs Through Panel Mount Socket SYS- Solder 300V, 7A PCB Mount Socket SYS-6 PCB mount 300V, 7A SYS-6 PCB mount 0V, 7A Electrical Life Curves RU (Resistive Load) RU (Resistive Load) RU (Resistive Load) ( 0,000 operations) 000 00 0 0V AC 30V DC 0V DC 0. 0. 0 ( 0,000 operations) 000 00 0 0V AC 30V DC 0V DC 0. 0. 3 6 ( 0,000 operations) 00 0 0V AC 30V DC 0V DC 0.0 0. 0. 3 6 RU (Inductive Load) RU (Inductive Load) RU (Inductive Load) ( 0,000 operations) 000 00 0 AC: cos ø = 0.3 DC: L/R = 7 ms 0V AC/30V DC 0V DC 0. 0. 0 Maximum Switching Current ( 0,000 operations) 00 0 AC: cos ø = 0.3 DC: L/R = 7 ms 0.0 0V AC 30V DC 0V DC 0. 0. ( 0,000 operations) 00 0 AC: cos ø = 0.3 DC: L/R = 7 ms RU RU RU (Bifurcated) 0 0. DC resistive DC inductive L/R = 7 ms 0 30 00 0 00 Load Voltage (V) AC resistive AC inductive (cos ø = 0.3) 0.0 0V AC 30V DC 0V DC 0. 0. Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 6

RU Timers Signaling Lights Switches & Pilot Lights Ambient Temperature vs. Temperature Rise Curves RU (AC Coil, 0 Hz) RU (AC Coil, 60 Hz) RU (DC Coil) Temperature Rise (C) 0 0 00 0 0 70 60 0 0 30 0 0 0 Load current 0A poles Load current A poles 0 No load current 0 30 0 0 Ambient Temperature (C) 60 70 Temperature Rise (C) 0 0 00 0 0 70 60 0 0 30 0 0 Load current 0A poles Load current A poles No load current 0 0 0 30 0 0 60 70 Ambient Temperature (C) Circuit Breakers Terminal Blocks Contactors Temperature Rise (C) 0 0 00 0 0 70 60 0 0 30 0 0 Load current 0A poles Load current A poles RU/RU (AC Coil, 0 Hz) RU/RU (AC Coil, 60 Hz) RU/RU (DC Coil) Temperature Rise (C) 0 0 00 0 0 70 60 0 0 30 0 0 Load current 3A poles Load current 6A poles No load current Temperature Rise (C) 0 0 00 0 0 70 60 0 0 30 0 0 Load current 3A poles Load current 6A poles No load current 0 0 0 30 0 0 60 70 0 0 0 30 0 0 60 70 0 0 Ambient Temperature (C) Ambient Temperature (C) The above temperature rise curves show the characteristics when 00% the rated coil voltage is applied. The heat resistance of the coil is 0 C. The slant dashed line indicates the allowable temperature rise for the coil at different ambient temperatures. Load current 6A x poles is for the RU models only. Temperature Rise (C) 0 0 00 0 0 70 60 0 0 30 0 0 No load current 0 0 0 30 0 0 60 70 Ambient Temperature (C) Load current 3A poles Load current 6A poles No load current 0 30 0 0 Ambient Temperature (C) 60 70 6 www.idec.com

RU Internal Connection (View from Bottom) RUS-* Standard RUS-*R with RC RUS-*D With Diode RUV-NF-* () () () () () () (3)A V AC/DC coil or less () () () (3)A ()A () () () ()A Over V AC/DC coil () () () (3)A () () () ()A () () () (3)A V DC coil or less () () () () () () (3)A () () () ()A ()A Over V DC coil RUS-*/RUS-* Standard RUS-*R/RUS-*R With RC RUS-*D/RUS-*D With Diode RUV-NF-*/RUV-NF-* () () (3)3 () () (6) (7)3 () () (0) ()3 () (3)A () () (3)3 () () (6) (7)3 () () (0) ()3 () (3)A ()A V AC/DC coil or less ()A Over V AC/DC coil RUS Marking Plate Removal Slot.0 0. 7. 3 () () () (0) ()3 () (3)A () (6) 3.0 6. (3)3 (7)3 () () ()A ø.. Hole Marking plate removal slot is provided only on one side. Insert a flat screwdriver into the slot to remove the marking plate. () () (3)3 () () (6) (7)3 () () (0) ()3 () (3)A V DC coil or less () () (3)3 () () (6) (7)3 () () (0) ()3 () (3)A Dimensions (mm).6 RUV ()A ()A Over V DC coil Marking Plate Removal Slot.0 7. Mounting Hole Layout 7.0. 0. 6..7 3.0.0 -ø Holes 3. 3. 0..6 0. () () () (3)A () () (3)A All dimensions in mm. () (6) (3)3 (7)3 () () () ()A () () () (0) ()3 () ()A Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 63

RU Switches & Pilot Lights RUS/RUS Dimensions con t (mm) RUV/RUV Circuit Breakers 6 3 7 Marking Plate Removal Slot 3.0 Marking Plate Removal Slot 3.0 Signaling Lights.0 0. 0..6 0 3 6. ø.. Hole.0 0..0 0..6 3-. 7. 7. Marking plate removal slot is provided only on one side. Insert a flat screwdriver into the slot to remove the marking plate. Mounting Hole Layout 7.0 -ø Holes 6...7. 3. All dimensions in mm. Spring Clamp DIN Rail Mount Sockets SUS-L SUS-L Timers 3 3 0.0 -ø3. Mounting Holes.0 -ø3. Mounting Holes 7 6 3 0. 37. 0 3. 37. 3 Contactors. 3 3.3 Standard DIN Rail Mount Sockets SMS-0 Ring terminals cannot be used. (Top View). Terminal Blocks SYS-0 3 3.3 Ring terminals cannot be used. (Top View) 3 6 0.7 30 6 6. M3 Terminal Screw 3.. DIN Rail (BNDN). max. -ø. Mounting Holes (or M Tapped Holes) 6 max.. min. ø3. min. 3 (Top View) 3 6 0.7 30 6 6. M3 Terminal Screw 3.. DIN Rail (BNDN) -ø. Mounting Holes (or M Tapped Holes) 6 max.. min.. max. ø3. min. 7 6 3 3 0 (Top View) 6 www.idec.com

RU Finger-safe DIN Rail Mount Sockets SMS-0C 6.6 30 6 6. M3 Terminal Screw ø. PCB Mount Sockets SMS-6 3 7. SYS-6 3 7... 3 3 0.3 6 0.3.. 3.. Through Panel Mount Socket SYS- 3 7.. 3.7 Panel Thickness: to 0.3 DIN Rail (BNDN) 3 (Bottom View) 3 6 7 0 3. 6 -ø. Mounting Holes (or M Tapped Holes) Ring terminals cannot be used. *. min. when using hold-down springs (Bottom View) *. min. when using hold-down springs. min.* 6. 3 6 7 0 3 (Bottom View). min.* 6. 0.. 0... +0. 0..6. min.*. 3. Dimensions con t (mm) 3 (Top View) 3. 3. min.. [7 (N ) +.] -ø holes (Tolerance 0.) 3. min. -ø holes (Tolerance 0.) +0. 0 N: No. of sockets mounted * 0. min. when using hold-down springs SYS-0C 6.6 30 6 SMS-6.. SYS-6.. 6. 3 M3 Terminal Screw ø. 3 0.3 6 0.3 3.. DIN Rail (BNDN) 3 (Bottom View) 3 6 7 0 3 (Bottom View) -ø. Mounting Holes (or M Tapped Holes) 6 Ring terminals cannot be used. 0. 6.. min.*.. 3. 7 6 3. min.** 3 0 (Top View) -ø holes (Tolerance 0.) * 7. min. when using a hold-down spring. ** 3. min. when using a hold-down spring for the relay with check button. 0. 6.. min.*... 3... min.** -ø holes (Tolerance 0.) * 7. min. when using a hold-down spring. * * 3. min. when using a hold-down spring for the relay with check button Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 6

RY/RM Switches & Pilot Lights RY/RM Series Miniature Relays Key features: RY (3A), RY (A), RM (A) General purpose miniature relays 3A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications All PDT types have arc barriers. Contactors Timers Signaling Lights Part Number Selection Part Number Contact Model Plug-in Terminal PC Board Terminal Coil Voltage Code DPDT (Slim) 3A DPDT (Wide) A PDT A Standard RYS-U 0 RYV-U 0 With Indicator RYS-UL 0 RYV-UL 0 With Check Button RYS-UC 0 With Indicator and Check Button RYS-ULC 0 Top Bracket Mounting RYS-UT 0 AC6V, ACV, ACV, AC0V, AC0V, AC0V, AC0V DC6V, DCV, DV, DCV, DC0V With Diode (DC coil only) RYS-UD 0 RYV-UD 0 DC6V, DCV, DCV, DCV, DC0V Standard RMS-U 0 RMV-U 0 With Indicator RMS-UL 0 RMV-UL 0 With Check Button RMS-UC 0 With Indicator and Check Button RMS-ULC 0 Top Bracket Mounting RMS-UT 0 With Diode (DC coil only) RMS-UD 0 With Indicator and Diode (DC coil only) RMS-ULD 0 Standard RYS-U 0 RYV-U 0 With Indicator RYS-UL 0 RYV-UL 0 With Check Button RYS-UC 0 With Indicator and Check Button RYS-ULC 0 Top Bracket Mounting RYS-UT 0 With Diode (DC coil only) RYS-UD 0 With Indicator and Diode (DC coil only) RYS-ULD 0 RYAC6V, ACV, ACV, AC0-0V, AC0-0V DC6V, DCV, DCV, DCV, DC00-0V DC6V, DCV, DCV, DCV, DC00-0V AC6V, ACV, ACV, AC0-0V, AC0-0V DC6V, DCV, DCV, DCV, DC00-0V DC6V, DCV, DCV, DCV, DC00-0V Terminal Blocks Top mount models are designed to mount directly to a panel and do not require a socket. Ordering Information When ordering, specify the Part No. and coil voltage code: (example) RYS-U AC0-0V Part No. Coil Voltage Code Circuit Breakers 66 www.idec.com

RY/RM Sockets Relays Standard DIN Rail Mount Finger-safe DIN Rail Mount Through Panel Mount RYS SYS-0 SYS-0C SYS- SYS-6 RM SMS-0 SMS-0C SMS- RYS SYS-0 SYS-0C SYS- Hold Down Springs & Clips Appearance Item Relay Pullover Wire Spring Leaf Spring (side latch) For DIN Mount Socket RYS SYS-0F SYS-F RM RYS RYS RM, RYS RYS Leaf Spring RM (top latch) RYS. Not available for PCB mount socket SYS-6.. Order pieces per relay. SYS-F SFA-0 SFA-0 SYS-6 SYS-6 For Through Panel & PCB Mount Socket SYS-F SFA-30 SFA-30 PCB Mount Accessories Item Appearance Use with Part No. Remarks Aluminum DIN Rail ( meter length) DIN Rail End Stop Replacement Hold-Down Spring Anchor All DIN rail sockets BNDN000 DIN rail BNL. mm wide. Horseshoe clip for all DIN rail sockets Y77-0 The BNDN000 is designed to accommodate DIN mount sockets. Made of durable extruded aluminum, the BNDN000 measures 0.3 (0.mm) in height and.37 (3mm) in width (DIN standard). Standard length is 3 (,000mm). For use on DIN rail mount socket when using pullover wire hold down spring. pieces included with each socket. Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 67

RY/RM Timers Signaling Lights Switches & Pilot Lights Specifications Contact Model Standard Contact RY - DPDT Slim RM - DPDT Wide RY - PDT Contact Material Gold-plated silver Silver Gold-plated silver Contact Resistance 0 mω maximum 30 mω maximum 0 mω maximum Minimum Applicable Load Operating Time Release Time Power Consumption (approx.) Insulation Resistance V DC, ma; V DC, 0 ma (reference value) AC:. VA (0 Hz), VA (60 Hz) DC: 0.W V DC, 0 ma; V DC, 0 ma (reference value) 0 ms maximum 0 ms maximum AC:. VA (0 Hz),. VA (60 Hz) DC: 0.W 00 MΩ minimum (00V DC megger) Between live and dead parts: V DC, ma; V DC, 0 ma (reference value) AC:. VA (0 Hz),. VA (60 Hz) DC: 0.W 00V AC, minute 000V AC, minute 000V AC, minute Between contact and coil: Dielectric Strength 00V AC, minute 000V AC, minute 000V AC, minute Between contacts of different poles: 00V AC, minute 000V AC, minute 000V AC, minute Between contacts of the same pole: 000V AC, minute 000V AC, minute 000V AC, minute Operating Frequency Electrical: 00 operations/h maximum Mechanical:,000 operations/h maximum Vibration Resistance Damage limits: 0 to Hz, amplitude 0. mm Operating extremes: 0 to Hz, amplitude 0. mm Shock Resistance Damage limits: 000 m/s Operating extremes: 00 m/s (DPDT Slim), 00 m/s (PDT, DPDT Wide) Mechanical Life 0,000,000 operations Electrical Life 00,000 operations (0V AC, 3A) 00,000 operations (0V AC, A) 00,000 operations (0V AC, A) 00,000 operations (0V AC, 3A) Operating Temperature 3 to + C (no freezing) to + C (no freezing) to + C (no freezing) Operating Humidity to % RH (no condensation) Weight (approx.) 3g 3g 3g Contactors Note: Above values are initial values.. Measured using V DC, A voltage drop method. Measured at the rated voltage (at 0 C), excluding contact bouncing Release time of relays with diode: 0 ms maximum 3. For use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve. The operating temperature range of relays with indicator or diode is to +0 C.. When the total current of contacts is less than A, the operating temperature range is to +70 C. Circuit Breakers Terminal Blocks 6 www.idec.com

RY/RM AC Coil Ratings Voltage (V) DPDT Slim Rated Current (ma) ±% at 0 C Coil Resistance (Ω) ±0% AC 0Hz AC 60Hz at 0 C DPDT Wide & PDT DPDT Slim DPDT Wide & PDT DPDT Slim DPDT Wide & PDT 6 70 0 0 00.. 6 7 00 76. 3.3 60. 37 0 300 3 0.6. 6,0 0-0.-0..0-.,0 0.6 7.,00 0.7., 0-0.7-..0-.6,0 0..3 6,70 DC Coil Ratings Voltage (V) Rated Current (ma) ±% at 0 C Coil Resistance (Ω) ±0% at 0 C DPDT Slim DPDT Wide & PDT DPDT Slim DPDT Wide & PDT 6 0 7 0 6 7 60 3 36. 70 60.,660,600 00-0.-.0,0 0 3,00 Contact Ratings Contact DPDT Slim (RY) DPDT Wide (RM) PDT (RY) Continuous Current 3A A A Maximum Contact Capacity Allowable Contact Power Rated Load Resistive Load Inductive Load Voltage (V) Res. Load Ind. Load 660 VA AC 0W DC 00VA AC 0W DC 00 VA AC 0W DC 76 VA AC W DC 0VA AC 7W DC VA AC 60W DC Note: Inductive load for the rated load cos ø = 0.3, L/R = 7 ms TÜV Ratings Voltage DPDT Slim DPDT Wide PDT 0V AC 3A A A 30V DC 3A A A AC: cos ø =.0, DC: L/R = 0 ms 0V AC 3A.A 0V AC 3A 0.A 30V DC 3A.A 0V AC A.A 0V AC A A 30V DC A.A 0V AC A.A 30V DC A A Max. Continuous Applied Voltage Operation Characteristics (against rated values at 0ºC) Max. Continuous Applied Voltage Pickup Voltage 0% 0% maximum Operation Characteristics (against rated values at 0ºC) Pickup Voltage Dropout Voltage 0% 0% maximum 0% minimum UL Ratings Voltage DPDT Slim Resistive DPDT Wide PDT Dropout Voltage 30% minimum DPDT Slim General use DPDT Wide PDT 0V AC 3A A A 0.A A A 0V AC.A.A 00V DC 0.A 0.A 0.A 0.A 0.A 30V DC 3A A A 3A A CSA Ratings Voltage DPDT Slim Resistive DPDT Wide PDT DPDT Slim General use DPDT Wide PDT 0V AC 3A A A 0.A A A 0V AC 3A A.A.A 00V DC 0.A 0.A 0.A 30V DC 3A A A.A.A.A Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 6

RY/RM Switches & Pilot Lights Signaling Lights Socket Specifications DIN Rail Mount Sockets Finger-safe DIN Rail Mount Through Panel Mount Socket PCB Mount Socket Sockets Terminal Electrical Rating Wire Size Torque SYS-0 M3 screws with captive wire clamp 300V, 7A Maximum up to #AWG. - in lbs SMS-0 M3 screw with captive wire clamp 300V, 0A Maximum up to #AWG. - in lbs SYS-0 M3 screw with captive wire clamp 300V, 7A* Maximum up to #AWG. - in lbs SYS-0C M3 screws with captive wire clamp, fingersafe 300V, 7A Maximum up to #AWG. - in lbs SMS-0C M3 screw with captive wire clamp, fingersafe 300V, 0A Maximum up to #AWG. - in lbs SYS-0C M3 screw with captive wire clamp, fingersafe 300V, 7A* Maximum up to #AWG. - in lbs SYS- Solder 0V, 7A SMS- Solder 0V, 0A SYS- Solder 0V, 7A* SYS-6 PCB Mount 300V, 7A SYS-6 PCB Mount 300V, 7A SYS-6 PCB Mount 0V, 7A * When using only poles of the -poles, the UL recognized current is 0A. Circuit Breakers Terminal Blocks Contactors Timers 70 www.idec.com

RY/RM Electrical Life Curves AC Load (RY) (RM) DC Load (RY) (RM) Life ( 0,000 operations) Life ( 0,000 operations) Life ( 0,000 operations) Life ( 0,000 operations) 000 00 00 00 0 0 0 0 000 000 00 00 00 00 00 0 0V AC resistive 0V AC resistive 0V AC inductive 0V AC inductive 3 0V AC resistive 0V AC resistive 0V AC inductive 0V AC inductive 0 0 3 0 30V DC resistive 30V DC inductive 0 00V DC resistive 0 00V DC inductive 0 3 000 00 00 0 30V DC resistive 30V DC inductive 00V DC resistive 00V DC inductive 0 0 3 Characteristics (Reference Data) (RY) ` (RY) Life ( 0,000 operations) Life ( 0,000 operations) 000 00 0V AC resistive 00 00 0V AC inductive 0 0 0 0 3 000 00 00 30V DC resistive 00 30V DC inductive 0 0 0 0 3 Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 7

RY/RM Switches & Pilot Lights Maximum Switching Capacity (RY) 3 DC inductive 0. AC resistive AC inductive DC resistive (RY) 3 0. DC resistive DC inductive AC resistive AC inductive 0.3 Signaling Lights (RM) 0. 0 0 00 00 300 Load Voltage (V) AC resistive 0. 0 0 30 0 00 00 300 Load Voltage (V) 0. 0. DC inductive AC inductive DC resistive 0 0 00 00 300 Load Voltage (V) Timers Contactors Continuous Load Current vs. Operating Temperature Curve (Standard Type, With Check Button, and Top Bracket Mounting Type) (RY) Operating Temperature (C) 00 0 0 70 60 0 0 30 0 0 0 AC Coil DC Coil 3 (RY) Operating Temperature (C) 00 0 0 70 60 0 0 30 0 0 0 AC Coil DC Coil 3 (RM) Operating Temperature (C) 00 Circuit Breakers Terminal Blocks 0 0 70 60 0 0 30 0 0 0 AC Coil DC Coil 3 7 www.idec.com

RY/RM Internal Connection (View from Bottom) Standard Type DPDT Slim (RY) DPDT Wide (RM) PDT (RY) With Check Button With Indicator (-L type) DPDT Slim (RY) DPDT Wide (RM) PDT (RY) Coil Below 00V AC/DC Coil 00V AC/DC and over Coil Below V AC/ DC Coil V AC/DC and over With Diode (-D type) DPDT Slim (RY) DPDT Wide (RM) PDT (RY) With Indicator and Diode (-LD type) DPDT Wide (RM) PDT (RY) DPDT Wide (RM) PDT (RY) Coil Below V DC Coil V DC and over 3( ) (+) Front Pushbutton Contacts can be operated by pressing the check button. When the relay is energized, the indicator goes on. An LED protection diode is not contained in DPDT relays for coils below 00V DC. If coil polarity is reversed LED will not light. Contains a diode to absorb the back emf generated when the coil is de-energized. The release time is slightly longer. Diode Characteristics Reverse withstand voltage:,000v Forward current: A 6 0 3 7 3( ) (+) Contains an LED indicator and a surge absorber. Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 73

RY/RM Switches & Pilot Lights Dimensions (mm) RYS RYS RMS Total length from panel surface including relay socket SYS-0: 6. (63.) max., SYS-: 3.6 (.6) max. 3 ø. oblong hole Dimensions in the ( ) include a hold-down spring. Total length from the panel surface including relay socket SYS-0: 6. (63.) max., SYS-: 3.6 (.6) max.. ø. oblong hole Dimensions in the ( ) include a hold-down spring. Total length from the panel surface including relay socket. SMS-0: 6. (63.) max., SMS-: 3.6 (.6) max. Dimensions in the ( ) include a hold-down spring.. ø. hole.6 Signaling Lights 0..6 3 3.6 max.. 7. 0..6 3 6 7 0 3 3.6 max. 6. 7. 0. 3 3.6 max. 6. 7. RYV RYV RMV 0. 0. 0..6 3 0. -ø holes 7. 7. 6..7..6 0. 0. 3 6 7 0 3 3.6 max.. -ø holes 6.6 0. 7. 7. 6..7..6 0. 0. 3 Timers Circuit Breakers Contactors Terminal Blocks 7. -ø hole.7. 3.6 max.... 3.6 max. 7. 3. 6. RYS-UT RYS-UT RMS-UT. 3. 3..6. 3 3 ø. oblong hole 0..6 6. 6.3.. 3 7. 3. 3. ø. oblong hole 0. 6... 6.3 3 6 7 0 3 7. 3. 3. ø. hole.6 0. 6.. 6.3 3 7. 3.. 3.6 max.. 3.. 3.6 max. 6. 3.. 3.6 max. 6. 7 www.idec.com

RY/RM Standard DIN Rail Mount Sockets SYS-0 6 3 6 0.7 7 6 0 6 SYS-0 30 6 6.. M3 Terminal Screw M3 Terminal Screw 3.. 3.. DIN Rail (BNDN) DIN Rail (BNDN) -ø. Mounting Holes (or M Tapped Holes) 6 max.. min.. max.. max. Finger-safe DIN Rail Mount Sockets SYS-0C.6 6 7. 6 6 0 ø. SYS-0C 6.6 M3 Terminal Screw 30 6 6. 6 M3 Terminal Screw ø. 3.. 6 DIN Rail (BNDN) 3.. 6 ø3. min. -ø. Mounting Holes (or M Tapped Holes) max.. min. 6 ø3. min. -ø. Mounting Holes (or M Tapped Holes) Ring terminals cannot be used. DIN Rail (BNDN) 6 Ring terminals cannot be used. -ø. Mounting Holes (or M Tapped Holes) Dimensions 3 (Top View) 7 6 3 3 0 (Top View) 3 (Top View) 7 6 3 3 0 (Top View) SMS-0 3 6 0.7 30 6 6 SMS-0C 6.6 30 6 6. M3 Terminal Screw ø.. M3 Terminal Screw 6 3.. 3.. DIN Rail (BNDN). max. -ø. Mounting Holes (or M Tapped Holes) 6 max.. min. DIN Rail (BNDN) 6 ø3. min. -ø. Mounting Holes (or M Tapped Holes) Ring terminals cannot be used. 3 (Top View) 3 (Top View) Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 7

RY/RM Switches & Pilot Lights Through Panel Mount Socket 3 SYS- 3.7 Panel Thickness: to 0.3. 3 (Bottom View) +0. 0. min.*.6 [(N )+.] +0. 0 N: No. of sockets mounted 3 SMS- 7. 3.7 Panel Thickness: to 0.3. 3 (Bottom View) +0. 0.6. min.* [7 (N ) +.] +0. 0 N: No. of sockets mounted * 0. min. when using hold-down springs Signaling Lights. SYS-. Panel Thickness: to * 0. min. when husing hold-down springs [7 (N ) +.] +0. 0. 3. 3 6 7 0 3 +0. 0.6 7.. 3.7 0.3 (Bottom View). min.* N: No. of sockets mounted * 0. min. when using hold-down springs PCB Mount Sockets SYS-6 SYS-6 Timers 3 Contactors Terminal Blocks Circuit Breakers.. 3 0.3. 3 (Bottom View). min.* 6. *. min. when using hold-down springs 0... 3.6 min. -ø holes (Tolerance 0.) 3 7.. 3 0.3. 3 6 7 0 3 (Bottom View) *. min. when using hold-down springs. min.* 6. 0.... 3.. 3. min. -ø holes (Tolerance 0.) SYS-6.. 3... min.** 0.3 3 6 7 0 3 0. 6.. 3 (Bottom View). -ø holes.. min.* (Tolerance 0.) * 7. min. when using a hold-down spring. * * 3. min. when using a hold-down spring for the relay with check button 76 www.idec.com

RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in LED indicator available. Fast response time ( ms maximum). High shock resistance (00 m/s minimum) Finger-safe DIN rail mount socket and PC board mount socket. Applicable Standard UL0 CSA C. No. EN00 EN60- Marking RFV Force Guided Relays/SFV Relay Sockets Part Number Certification Organization/ File Number UL/c-UL File No. E6 TÜV SÜD Part Number Selection Contact Without LED Indicator With LED Indicator Rated Coil Voltage -pole 6-pole Sockets NO-NC 3NO-NC NO-NC NO-NC 3NO-3NC RFV-AB-D RFV-ABL-D V DC RFV-AB-D RFV-ABL-D V DC RFV-AB-D RFV-ABL-D V DC RFV-3AB-D RFV-3ABL-D V DC RFV-3AB-D RFV-3ABL-D V DC RFV-3AB-D RFV-3ABL-D V DC RFV-AB-D RFV-ABL-D V DC RFV-AB-D RFV-ABL-D V DC RFV-AB-D RFV-ABL-D V DC RFV-AB-D RFV-ABL-D V DC RFV-AB-D RFV-ABL-D V DC RFV-AB-D RFV-ABL-D V DC RFV-3A3B-D RFV-3A3BL-D V DC RFV-3A3B-D RFV-3A3BL-D V DC RFV-3A3B-D RFV-3A3BL-D V DC Style No. of Poles Ordering Type No. DIN Rail Mount Sockets PC Board Mount Sockets SFV--07L 6 SFV-6-07L SFV--6 6 SFV-6-6 Certification for Sockets Applicable Standard UL0 CSA C. No. EN7000 EN700 Marking Certification Organization/ File Number UL/c-UL File No. E637 TÜV SÜD EC Low Voltage Directive (DIN rail mount sockets only) Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 77

RFV Switches & Pilot Lights Signaling Lights Coil Ratings -pole 6-pole Contact NO-NC 3NO-NC NO-NC NO-NC 3NO-3NC Rated Coil Voltage (V) Rated Current (ma) ±0% (at 0 C) V DC 30 00 V DC 600 V DC 7. 600 V DC 30 00 V DC 600 V DC 7. 600 V DC.7 V DC 0. V DC 0. 60 V DC.7 V DC 0. V DC 0. 60 V DC.7 V DC 0. V DC 0. 60 Coil Resistance (Ω) ±0% (at 0 C) Pickup Voltage. For relays with LED indicator, the rated current increases by approx. ma.. Maximum continuous applied voltage is the maximum voltage that can be applied to relay coils. Operating Characteristics (at 0 C) Dropout Voltage 7% maximum 0% minimum 0% Maximum Continuous Applied Voltage Power Consumption Approx. 0.36W Approx. 0.W Accessories Item Appearance Specifications Type No. Remarks Timers DIN Rail Aluminum Weight: Approx. 0g BNDN000 Length: Width: m 3 mm BNL End Clip Metal (zinc plated steel) Weight: Approx. g BNL6 Circuit Breakers Terminal Blocks Contactors 7 www.idec.com

RFV Specifications Number of Poles -pole 6-pole Contact Configuration NO-NC 3NO-NC NO-NC NO-NC 3NO-3NC Contact Resistance (initial value) Contact Material Rated Load (resistive load) Allowable Switching Power (resistive load) Allowable Switching Voltage Allowable Switching Current Minimum Applicable Load 00 mω maximum AgSnO (Au flashed) 6A 0V AC, 6A 30V DC 00 VA, 0W 0V AC, 30V DC 6A V DC, ma (reference value) Power Consumption (approx.) 0.36W 0.W Insulation Resistance Between contact and coil Dielectric Strength Between contacts of different poles 000 MΩ minimum (00V DC megger, same measurement positions as the dielectric strength) 000V AC, minute 00V AC, minute Between contacts 7- and -0 000V AC, min. Between contacts 3- and -6 Between contacts 3- and 7- Between contacts -6 and -0 00V AC, minute Between contacts 7- and - Between contacts -0 and 3- Between contacts - and 3-000V AC, min. Between contacts 3- and -6 Between contacts 3- and 7- Between contacts -6 and -0 Between contacts 7- and -0 Between contacts of the same pole 00V AC, minute Operating Time (at 0 C) 0 ms maximum (at the rated coil voltage, excluding contact bounce time) Response Time (at 0 C) 3 ms maximum (at the rated coil voltage, excluding contact bounce time) Release Time (at 0 C) 0 ms maximum (at the rated coil voltage, excluding contact bounce time) Vibration Operating Extremes 0 to Hz, amplitude 0.7 mm Resistance Damage Limits 0 to Hz, amplitude 0.7 mm Shock Operating Extremes (half sine-wave pulse: ms) 00 m/s, when mounted on DIN rail mount socket: 0 m/s Resistance Damage Limits (half sine-wave pulse: 6 ms) 000 m/s Electrical Life 0V AC 6A resistive load: 00,000 operations minimum (operating frequency 00 per hour) 30V DC 6A resistive load: 00,000 operations minimum (operating frequency 00 per hour) 0V AC A resistive load: 00,000 operations minimum (operating frequency 00 per hour) 30V DC A resistive load: 00,000 operations minimum (operating frequency 00 per hour) [AC ] 0V AC A inductive load: 00,000 operations minimum (operating frequency 00 per hour, cos ø = 0.3) [DC 3] V DC A inductive load: 00,000 operations minimum (operating frequency 00 per hour, L/R = ms) Mechanical Life 0 million operations minimum (operating frequency 0,00 operations per hour) Operating Temperature 0 to + C (no freezing) Operating Humidity to %RH (no condensation) Storage Temperature 0 to + C Operating Frequency (rated load) 00 operations per hour Weight (approx.) 0g 3g. Measured using 6V DC,A voltage drop method.. Failure rate level P (reference value) 3. Response time is the time until NO contact opens, after the coil voltage is turned off.. When using at 70 to C, reduce the switching current by 0.A/ C. Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 7

RFV Switches & Pilot Lights Signaling Lights Socket Specifications Part Number SFV--07L SFV-6-07L SFV--6 SFV-6-6 Rated Current Rated Voltage 6A 0V AC/DC Insulation Resistance 000 MΩ minimum (00V DC megger, between terminals) Dielectric Strength 00V AC, minute (between terminals) Screw Terminal Style M3 slotted Phillips screw Applicable Wire 0.7 to.6 mm ( AWG to AWG) Recommended Screw Tightening Torque 0. to 0. N m Terminal Strength Wire tensile strength: 0N min. Vibration Resistance Damage limits: 0 to Hz, amplitude 0.7 mm Resonance: 0 to Hz, amplitude 0.7 mm Shock Resistance 000 m/s Operating Temperature 0 to + C (no freezing) Operating Humidity to % RH (no condensation) Storage Humidity 0 to + C Degree of Protection IP0 (finger-safe screw terminals) Weight (approx.) 0g g g 0g. When using at 70 to C, reduce the switching current by 0.A/ C. Applicable Crimping Terminals Specifications 6.3 max. 3.0 min..0 max. 6. min. Note: Ring tongue terminals cannot be used. Characteristics Maximum Switching Capacity Electrical Life Curve Notes on Contact Gaps except Welded Contacts Timers Contactors AC Resistive Load 0 6 DC Resistive Load 0. 0 00 0 Load Voltage (V) Life ( 0,000 operations) 00 00 0 0V AC Resistive Load 30V DC Resistive Load 0. 0 Example: RFV-AB-D + Circuit Breakers Terminal Blocks 3 6 7 0 If the NO contact (7- or -0) welds, the NC contact (3- or -6) remains open even when the relay coil is de-energized, maintaining a gap of 0. mm. The remaining unwelded NO contact (-0 or 7-) is either open or closed. If the NC contact (3- or -6) welds, the NO contact (7- or -0) remains open even when the relay coil is energized, maintaining a gap of 0. mm. The remaining unwelded NC contact (-6 or 3-) is either open or closed. 0 www.idec.com

RFV RFV Dimensions (mm) RFV (-pole) RFV (6-pole) PC Board Terminal type Mounting Hole Layout (Bottom View) 0 max. 0 max. RFV (-pole) max. 3. 3 max..0.3 0. 0.6 3.7.0.0.3 Internal Connection (View from Bottom) With Indicator and Diode (-LD type) RFV (-pole) Without LED Indicator + 3 7 6 0 NO-NC Contact With LED Indicator 3 7 + 6 0 NO-NC Contact max. 3. 3 7 + 6 0 3NO-NC Contact 3 7 + 6 0 3NONC Contact 3 max..0.3 0.6 3.7.0 RFV (6-pole) Without LED Indicator + 3 7 6 03 NO-NC Contact With LED Indicator + 3 7 6 03 NO-NC Contact 0..0.0.0.3 + + ±0. 0.6 0-. hole (.3).0 ±0. 3.7±0..3 ±0..0 RFV (6-pole) ±0. 0.6 3 (.3) 3.7±0. ±0..0 7 6 03 NO-NC Contact 3 7 6 03 NO-NC Contact + + -. hole.0 ±0..0 ±0..0 ±0..3 ±0. 3 7 6 03 3NO-3NC Contact 3 7 6 03 3NO-3NC Contact Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada

RFV Switches & Pilot Lights Signaling Lights SFV--07L (-pole) (Internal Connection) 0 7 6 3 (Top View) SFV DIN Rail Mount Socket Dimensions (mm) M3 Terminal Screw ø6. R SFV-6-07L (6-pole) (Internal Connection) 6. 7 6. 3 0 6 3 (Top View) 7 M3 Terminal Screw ø6. R 6. 7 6. 6.3 6.3 Circuit Breakers Terminal Blocks Contactors Timers 6...3 6...3 3.. 3.. (Panel Mounting Hole Layout) (Panel Mounting Hole Layout) 0.0 ±0. M3. or ø holes 0.0 ±0. M3. or ø holes. ±0. ±0. (Top View) (Top View) www.idec.com

RFV SFV--07L (-pole) (3) 6.3 3.7.0 0 max. 6. max. (3) 0..0.3 3-ø3. holes for M3 self-tapping screws 0.6 ±0.. ±0.. ±0. (6.3 3.7 ±0..0 ±0. 3. ±0. 0 max..3 ±0..0 ±0. 3. 0- ø. hole 0. 0.6 0.6 3.6 3 SFV PC Board Mount Sockets 7 6 0 SFV-6-07L (6-pole) ±0. (3) 6.3 3.7.0 60 max. ±0. 6. ±0. ±0... max. (3) 0..0.0.0.3 3-ø3. holes for M3 self-tapping screws 0.6 (6.3) 3.7±0..0. ±0. 0 max..0.0.3±0. ±0. ±0..0 3. 0. 0.6 -ø. hole 0.6 3.6 3 7 6 0 3 Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 3

Operating Instructions Terminal Blocks Contactors Timers Signaling Lights Switches & Pilot Lights Driving Circuit for Relays. To ensure correct relay operation, apply rated voltage to the relay coil.. Input voltage for the DC coil: A complete DC voltage is best for the coil power to make sure of stable relay operation. When using a power supply containing a ripple voltage, suppress the ripple factor within %. When power is supplied through a rectification circuit, the relay operating characteristics, such as pickup voltage and dropout voltage, depend on the ripple factor. Connect a smoothing capacitor for better operating characteristics as shown below. Smoothing Capacitor + R Relay Operating Instructions Protection for Relay Contacts Pulsation Emin Emax Emean DC Ripple Factor (%) Emax Emin Emean 00% Emax = Maximum of pulsating current Emin = Minimum of pulsating current Emean = DC mean value 3. Leakage current while relay is off: When driving an element at the same time as the relay operation, special consideration is needed for the circuit design. As shown in the incorrect circuit below, leakage current (Io) flows through the relay coil while the relay is off. Leakage current causes coil release failure or adversely affects the vibration resistance and shock resistance. Design a circuit as shown in the correct example. Incorrect R Io TE Correct. Surge suppression for transistor driving circuits: When the relay coil is turned off, a high-voltage pulse is generated, causing a transistor to deteriorate and sometimes to break. Be sure to connect a diode to suppress the back electromotive force. Then, the coil release time becomes slightly longer. To shorten the coil release time, connect a Zener diode between the collector and emitter of the transistor. Select a Zener diode with a Zener voltage slightly higher than the power voltage. Back emf suppressing diode + R Relay R. The contact ratings show maximum values. Make sure that these values are not exceeded. When an inrush current flows through the load, the contact may become welded. If this is the case, connect a contact protection circuit, such as a current limiting resistor.. Contact protection circuit: When switching an inductive load, arcing causes carbides to form on the contacts, resulting in increased contact resistance. In consideration of contact reliability, contact life, and noise suppression, use of a surge absorbing circuit is recommended. Note that the release time of the load becomes slightly longer. Check the operation using the actual load. Incorrect use of a contact protection circuit will adversely affect switching characteristics. Four typical examples of contact protection circuits are shown in the following table: RC Diode Varistor Power + Power Power C D Varistor R Ind. Load Ind. Load Ind. Load This protection circuit can be used when the load impedance is smaller than the RC impedance in an AC load power circuit. R: Resistor of approximately the same resistance value as the load C:0. to µf This protection circuit can be used for both AC and DC load power circuits. R: Resistor of approximately the same resistance value as the load C: 0. to µf This protection circuit can be used for DC load power circuits. Use a diode with the following ratings. Reverse withstand voltage: Power voltage of the load circuit x 0 Forward current: More than the load current This protection circuit can be used for both AC and DC load power circuits. For a best result, when using a power voltage of to V AC/DC, connect a varistor across the load. When using a power voltage of 00 to 0V AC/DC, connect a varistor across the contacts. 3. Do not use a contact protection circuit as shown below: C Power C Power Load Load This protection circuit is very effective in arc suppression when opening the contacts. But, the capacitor is charged while the contacts are opened. When the contacts are closed, the capacitor is discharged through the contacts, increasing the possibility of contact welding. This protection circuit is very effective in arc suppression when opening the contacts. But, when the contacts are closed, a current flows to charge the capacitor, causing contact welding. Generally, switching a DC inductive load is more difficult than switching a DC resistive load. Using an appropriate arc suppressor, however, will improve the switching characteristics of a DC inductive load. Soldering Circuit Breakers. When soldering the relay terminals, use a soldering iron of 30 to 60W, and quickly complete soldering (within approximately 3 seconds).. Use a non-corrosive rosin flux. www.idec.com

Operating Instructions Other Precautions. General notice: To maintain the initial characteristics, do not drop or shock the relay. The relay cover cannot be removed from the base during normal operation. To maintain the initial characteristics, do not remove the relay cover. Use the relay in environments free from condensation, dust, sulfur dioxide (SO ), and hydrogen sulfide (H S). Make sure that the coil voltage does not exceed applicable coil voltage range. Turn off the power to the relay before starting installation, removal, wiring, maintenance, and inspection of the relays. Failure to turn power off may cause electrical shock or fire hazard. Observe specifications and rated values, otherwise electrical shock or fire hazard may be caused. Use wires of the proper size to meet voltage and current requirements. Tighten the terminal screws on the relay socket to the proper tightening torque. Surge absorbing elements on AC relays with RC or DC relays with diode are provided to absorb the back electromotive force generated by the coil. When the relay is subject to an excessive external surge voltage, the surge absorbing element may be damaged. Add another surge absorbing provision to the relay to prevent damage. Operating Instructions con t. UL and CSA ratings may differ from product rated values determined by IDEC. 3. Do not use relays in the vicinity of strong magnetic field, as this may affect relay operation. Safety Precautions Precautions for the RU Relays Before operating the latching lever of the RU relay, turn off the power to the RU relay. After checking the circuit, return the latching lever to the original position. Do not use the latching lever as a switch. The durability of the latching lever is a minimum of 00 operations. When using DC loads on PDT relays, apply a positive voltage to terminals of neighboring poles and a negative voltage to the other terminals of neighboring poles to prevent the possibility of short circuits. DC relays with a diode have a polarity in the coil terminals. Apply the DC voltage to the correct terminals. Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada

RSC Switches & Pilot Lights Signaling Lights Key features: Slim design allows for DIN rail or panel mounting Built-in heat sink maximizes current output capability Epoxy-free design Choice of 0A, 30A and A models LED indicator Finger-safe terminals Zero voltage switching Back-to-back SCR output Direct Bond Copper (DBC) substrate construction Built-in transient protection (TVS) 00k-cycle UL0 endurance rating UL Recognized, TUV Approved, CE Marked Lead free and RoHS compliant EMC (Level 3) & IEC 63 compliant UL Recognized File No. E77 RSC Series Solid State Relays Timers Contactors Part Number Selection -3V DC 0-0V AC Input Control Voltage 0-0V AC Output Current Rating 0A 30A A 0A 30A A 0A 30A A Part Number RSCDN-0A RSCDN-30A RSCDN-A RSCAN-0A RSCAN-30A RSCAN-A RSCAN-0A RSCAN-30A RSCAN-A* Specifications General Characteristics Model 0A 30A A -0 to +0 Operating temperature (ºC) -0 to +60 (0-0 V AC input models) Storage temperature (ºC) -0 to +00 Input-to-Output isolation voltage (Vrms) 00 Input/Output to ground isolation voltage (Vrms) 000 Terminal Blocks *Input control voltage is 0-60V AC. Circuit Breakers Operating frequency (Hz) 7 to 63 Housing material Heat sink material UL-V0 Self-extinguishing polycarbonate Anodized aluminum black Protection (IEC 60) - Casing IP0 Input terminal wire size (stranded and solid) 6 AWG to AWG Input terminal tightening torque (Nm) 0. Output terminal wire size (stranded) AWG to 6 AWG Output terminal wire size (solid) 0 AWG to 6 AWG Output terminal tightening torque (Nm).3 Weight (g) 00 6 www.idec.com

RSC Specifications con t Safety Standards Input Specifications Output Specifications Conformity to standards Model 0A 30A A Vibrations according to IEC/ EN6006--6 Shock test IEC 6006--7 Immunity to electrostatic discharges IEC/EN 6000-- Immunity to electrostatic fields ENV 00/0 (IEC 000--3) Immunity to rapid transient bursts to IEC 000-- Immunity to shock waves according to IEC/EN 6000-- Immunity to radio frequency in common mode acc. to ENV (CEI 000--6) Conducted and radiated noise for industrial environments per CISPR IEC 63 IEC 607--3 (AC ) IEC 607-- (AC 3a) CE compliant with LVD 73/3/EEC TUV certified per EN 600 c-ur per C..no. - UL recognized per UL 0 3 mm / 0- Hz G / ms Level 3 Level 3 Level 3 Level 3 Level 3 Class A Pollution Degree Overvoltage Model Category III 0A, 30A, A Input voltage (V) -3V DC 0-0V AC 0-0V AC* Turn-off voltage (V) 0 0 Max. controlled current (ma) 0 6 Min. input current (ma) 6 6 Turn-on time (ms).33 (60Hz) / 0 (0Hz) 30 30 Max. turn-off time (ms).33 (60Hz) / 0 (0Hz) 30 30. LED is not an absolute indicator of power being present.. *A model is 0-60V AC Model 0A 30A A Voltage range (Vrms max) -600-600 -600 Non-rep. peak voltage (Vpeak) 00 00 00 Maximum off-state leakage at Vmax and T = ºC (µa) 0 0 0 Current max @ 0ºC (A) 0 30 Minimum current (ma) 00 00 00 On-state voltage drop at I max (Vpeak)...3 I t (t = 0 ms) (A s) (0/60 Hz) /00 0/30 300/600 Static (off-state) dv/dt (V/µs) 00 00 00 HP ratings at 0V / 3/. HP ratings at 0V 3 HP ratings at 0V Utilization category AC- (A) 0 30 Utilization Category AC-3 (A) 6 0 Max. non-rep. s surge (T=ºC) (A) 00 0 60 Max. non-rep.-cycle surge (T=ºC) (A) 70 00 Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada 7

RSC Switches & Pilot Lights Dimensions (mm) 0A/30A Models Circuit Breakers Terminal Blocks Contactors Timers Signaling Lights A Model www.idec.com

RSS Key features: Input status LED Indicator Dual SCR output Direct bond copper substrate Internal transient protection built-in snubber EMC compliant (level 3) Photo isolation 00 Volt blocking voltage 000 Volt optical isolation Zero voltage turn-on High surge capability Optional fingersafe terminal cover (RSS-CVR) UL Recognized File No. E77 Part Number Selection AC Input 0-0V AC DC Input -3V DC Input Continuous Output Current 0A A 0A 7A 0A 0A A 0A 7A 0A RSS Series Panel Mount Solid State Relays Part Number RSSAN-0A RSSAN-A RSSAN-0A RSSAN-7A RSSAN-0A RSSDN-0A RSSDN-A RSSDN-0A RSSDN-7A RSSDN-0A Specifications Input Specifications Output Specifications Series RSSDN RSSAN Voltage Range to 3V DC 0 to 0V AC Input Current current regulated (0mA) Pick Up Voltage V DC 0V AC Drop Out Voltage V DC 0V AC Dielectric Strength (Input-Output-Base) 000 RMS (min) 000 RMS (min) Capacitance (Input to Output) pf pf Rev. Voltage Protection Yes ( 3VDC) N/A Current (continuous) 0A A 0A 7A 0A -Cycle Surge Current 0A 300A 70A 000A 00A -Second Surge Current 30A 7A 0A A 300A Minimum Holding Current 0mA 0mA 00mA 00mA 00mA Voltage Drop at Rated Current.6V (maximum) Voltage Range - 660V AC Output Dual SCR (N.O.) Over Voltage Rating 00 PIV Frequency Range 7 to 0Hz Off-State Leakage at Rated Voltage 0mA (maximum) Turn-On Time / cycle @ 60Hz Turn-Off Time / cycle @ 60Hz Zero Voltage Switching Yes Static DV/DT 00V/µsec Commutating DV/DT Snubbed for 0. power factor at rated load Weight 0g (approx.) Switches & Pilot Lights Signaling Lights Timers Contactors Terminal Blocks Circuit Breakers 00-6-IDEC (33) USA & Canada