Series AMEPR60-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Similar documents
Series AM50E-NZ 50 Watt DC-DC Converter

Series AMSRL1-78JZ Up to 12 Watt DC-DC Switching Regulator

Output Current Max (ma) Isolation (VDC)

Series AMLD-IZ Up to 2000mA LED Driver

Series AMLDV-NZ Up to 700mA LED Driver

Series AM20EW-Z 20 Watt DC-DC Converter

Series AM2L-NZ 2 Watt DC-DC Converter

Series AMLDP-Z Up to 1000mA LED Driver

Series AMEOW10-NZ 10 Watt AC-DC / DC-DC Converter

Series AMLD-Z Up to 1000mA LED Driver

Series AMLD-Z Up to 1000mA LED Driver

Series AM30EW-Z 30 Watt DC-DC Converter

Series AMLBW-Z Up to 700mA Step Up LED Driver

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

Series AM1L-NZ 1 Watt DC-DC Converter

Series AM30EW-Z 30 Watt DC-DC Converter

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Series AMLDL-Z Up to 1000mA LED Driver

200W. 200 Watt - LD200W Series CONSTANT VOLTAGE OR CONSTANT CURRENT LED DRIVER WITH DIMMING. LED Optimized Drivers. LD200W Series.

150W. 150 Watt - LD150W Series CONSTANT VOLTAGE OR CONSTANT CURRENT LED DRIVER WITH DIMMING. LED Optimized Drivers. LD150W Series.

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

75W Constant Current (700mA) LED Driver

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

HEC-30/35LTA-33TDAA Rev A

3 in 1 Dimmable (0-10Vdc, PWM signal, or resistance)

Environmental. Electrical Specifications at 25 O C TYPE TL TYPE HL. Output Voltage. Output Constant Current

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

HEC-35LTA-XXTSAA Rev A

HEC-45LTN-45PFAS Rev A

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Environmental. Electrical Specifications at 25 O C TYPE HL. Output Constant Current. Output Voltage Range

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

SAMSUNG ELECTRO-MECHANICS CO., LTD

50W Constant Current (700mA) Dimming LED Driver

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Series AMLDLW-Z Up to 1000mA LED Driver

VP ELECTRONIQUE MASSY - Tel:

Typical Efficiency (2) Max. Output Power. 24 Vdc 90 ~ 305 Vac 0~1080mA 26 W 84% EUV-026S024PS(3)

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

Output Voltage Range ma ma 700 ma 176~305 Vac 160~357 Vdc 250W 93% 0.98 EBD-255S105DV

AC - DC 150W LED Driver MDC150 Single Output Series

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC

PDAM500 Series 500W Power Supply

Typical Efficiency (2)

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

AC - DC 96W LED Driver MDC100 Single Output Series

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

SAMSUNG ELECTRO-MECHANICS CO., LTD

Max. Output Power. Typical Efficiency (2) 700 ma 90~305 Vac 54~108 Vdc 75 W 90% EUC-075S070DD(SD) Parameter Min. Typ. Max.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

HEC-70LCN-350TDAF Rev B

Typical Efficiency (2) 350 ma 90 ~ 305 Vac 52~103 Vdc 36 W 89% EUC-036S035DV(SV)

AC/DC Converter LD20-26Bxx Series

AC - DC 120~150W LED Driver MDC120 Single Output Series

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

IEC/EN/UL60950 & CE certified, EN55032 Class B

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Output Voltage Range. Max. Output Power

Max. Output Power. Typical Efficiency (2) 700 ma 90~305 Vac 54~108 Vdc 75 W 90% EUC-075S070DD(SD)

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

MODEL MCHQ250V12B MCHQ250V24B MCHQ250V54B

IP65 IP67. Can be adjusted by internal potentiometer A type only. 500ms, 80ms / 347VAC / 480VAC at 95% load 180 ~ 528VAC 254VDC ~ 747VDC 47 ~ 63Hz

AC-DC Switching ADAPTER TRE25R VI Series APPLICATION NOTE

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 428 Vdc 150 W 93.5% EUC-150S035DT

Max. Output Power. Typical Efficiency (2) 500 ma 90 ~ 305 Vac 60 ~ 120 Vdc 60 W 90.0% EUC-060S070STM0004

AC - DC 96W LED Driver MDC100 Single Output Series

SELV. 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed

Output Voltage Range. Max. Output Power

H L G -150H s er i es

Output Voltage Range (V) PF-P250CC-C105-S(U)-ND 90 ~ ,0 UL CE ENEC CB

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Typical Efficiency (2)

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

MCHQ80VxB series ELECTRICAL SPECIFICATION. 80W LED Switching Power Supply (CV+CC) with 3 in 1 dimming function OUTPUT INPUT

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT

Max. Output Power. Typical Efficiency (2) 12 Vdc 90 ~ 305 Vac 0~22.9 A 275 W 91.5% EUV-300S012ST

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

Output Voltage* (nom.)(adjustable)

Metal Case Power Supplies

150 Watt Industrial (WLT)

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

VOF XX - XXX - X

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

Transcription:

Click on Series name for product info on aimtec.com Series AMEPR60-AZ Models Single output FEATURES: AC-DC Constant Current or Constant Over Temperature Protection Voltage LED Driver Over Current Protection Input range 90-305VAC/47-440Hz Waterproof Case rated IP68 High Efficiency up to 89% Power Factor Correction Operating temperature -40 to 85 C Dimmable via resistive / 0-10Vdc / PWM 5 Years Limited Warranty Short Circuit Protection Output Max Output Voltage Input Input Model Current OCP / Output Efficiency Range Voltage Voltage Mode of Operation (V) 3 3 OVP Power (%) (VAC/Hz) (VDC) (W) 1 90-305 / Constant Current 1.27 60 89 AMEPR60-50120AZ 36-50 0-1.20 130-430 47-440 Constant Voltage 2 50.7 63.8 86 90-305 / Constant Current 1.77 59.8 88 AMEPR60-36170AZ 24-36 0-1.70 130-430 47-440 Constant Voltage 2 36.6 63.7 86 90-305 / Constant Current 2.55 60 87 AMEPR60-24250AZ 12-24 0-2.50 130-430 47-440 Constant Voltage 2 24.5 61 85 90-305 / Constant Current 5.2 60 85 AMEPR60-12500AZ 5-12 0-5.0 130-430 47-440 Constant Voltage 2 12.3 62 82 1 Exceeding the maximum output power will permanently damage the converter 2 The dimming feature is not supported when units are used in Constant Voltage mode only. 3 In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add NA to part number when ordering. Note: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25 C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-sale AMEPR60-AZ s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to dirty electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. Input Specifications Parameters Conditions Typical Maximum Units Inrush current <2ms 115VAC 30 230VAC 50 A Leakage current 115VAC 0.5 230VAC 0.7 ma AC current 115VAC 0.73 230VAC 0.33 A Power Factor 115VAC 0.97 230VAC 0.93 External fuse 250V/1.5A Start up time 250 ms Surge voltage 2sec 440 V F 052.1e R3.AE 1 of 13 North America only

Output Specifications Parameters Conditions Typical Maximum Units Current accuracy (CC Mode) ±3 % Voltage accuracy (CV Mode) ±3 % Line regulation LL-HL ±1 % Load regulation 0-100% load ±3 % Ripple & Noise 4 20MHz Bandwidth 75 mv p-p Hold-up time 90 ms Current adjustment range 5 100-10 % Minimum Load Voltage See the models table 4 Tested with 0.1µF (C/C) or (M/C) and 47µF (E/C) parallel capacitors at the end. 5 Note: from 0% to 10% dimming adjustment signal instability may be present. Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 3 sec/3.5ma 3000 VAC Isolation Resistance 500VDC >1000 MΩ Isolation Capacitance 1000 pf General Specifications Parameters Conditions Typical Maximum Units Switching frequency 130 KHz AMEPR60-50120AZ 1.27 Over current protection AMEPR60-36170AZ 1.77 AMEPR60-24250AZ 2.55 A AMEPR60-12500AZ 5.2 Over voltage protection Refer to Constant Current vs. Constant Voltage Mode curve Short circuit protection Continuous Short circuit restart Auto recovery Over temperature protection >105 C Operating temperature With derating over 55 C -40 to +85 o C Maximum case temperature 100 o C Storage temperature -40 to +95 o C Temperature coefficient ±0.02 % / o C Cooling Free air convection Humidity 95 % RH Case material Plastic Potting Epoxy (IP67 rated) Wires UL1015 18AWG *20CM Weight 530 g Dimensions (L X W X H) 5.30 x 2.27 x 1.59 inches 134.80 x 57.68 x 40.50 mm MTBF >400,000 hrs (MIL-HDBK-217F at +25 C) Safety Specifications Parameters Agency approvals Standards culus, CE UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13 Information Technology Equipment EN55022 Class B Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient / Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 1 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 F 052.1e R3.AE 2 of 13 North America only

Dimensions Top View 134.80 (5.30) End View 40.50 (1.59) 16.75 (0.66) 57.68 (2.27) 32.00 57.68 (1.26) (2.27) Side View 40.50 (1.59) 200.00 (8.00) 200.00 (8.00) Input/Output Wires are 18 AWG 20cm 158.50 (6.24) 2.30 (0.09) Wire connection: Wire Brown Blue Green Red Black Blue (Dimming) White (Dimming) Connection AC L AC N Ground +V output -V Output + Vs dimming -Vs dimming AMEPR60-AZ Analog (resistive) Dimming Application Circuit Model Number Maximum Pot Value (kω) AMEPR60-50120AZ 26.00 AMEPR60-36170AZ 16.95 AMEPR60-24250AZ 26.10 AMEPR60-12500AZ 34.10 F 052.1e R3.AE 3 of 13 North America only

AMEPR60-AZ Analog (0-10V) Dimming Application Circuit Series AMEPR60-AZ AMEPR60-AZ PWM (1KHz) Dimming Application Circuit Temperature Graph F 052.1e R3.AE 4 of 13 North America only

Efficiency Vs. Input Voltage & Output Current (Constant Current Mode) AMEPR60-50120AZ (%) Efficiency VS. Input Voltage & Output Current 230Vac, 1.2, 115Vac, 0.24, 277Vac, 87.771.2, 115Vac 82.323 115Vac, 87.641.2, 277Vac, 0.24, 86.6 230Vac 277Vac 74.59 230Vac, 0.24, 74.12 AMEPR60-36170AZ (%) Efficiency VS. Input Voltage & Output Current 277Vac, 86.82 110Vac 1.7, 110Vac, 0.34, 110Vac, 86.8 1.7, 83.02 85.53 230Vac 230Vac, 76.28 277Vac 0.34, 76.26 F 052.1e R3.AE 5 of 13 North America only

AMEPR60-24250AZ (%) Efficiency VS. Input Voltage & Output Current 230Vac, 2.5, 277Vac, 85.49115Vac 2.5, 115Vac, 0.5, 115Vac, 85.3230Vac 2.5, 230Vac, 0.5, 82.77 84.79 277Vac 74.19 277Vac, 0.5, 74.2 AMEPR60-12500AZ (%) Efficiency VS. Input Voltage & Output Current 110Vac, 1, 230Vac, 82.6 1, 74.9277Vac, 1, 74.9 230Vac, 110Vac 277Vac, 5, 84 110Vac, 83.9 230Vac 5, 83.43277Vac F 052.1e R3.AE 6 of 13 North America only

PFC Value vs. Output Load Current (Constant Current Mode) AMEPR60-50120AZ Series AMEPR60-AZ (PF) PF VS. Output Current 115VAC, 0.6, 115VAC, 115VAC 1.2, 230VAC, 0.9960.6, 230VAC, 230VAC 1 1.2, 277VAC, 0.9570.6, 277VAC, 0.9881.2, 290VAC, 0.8930.6, 290VAC, 0.962 277VAC 1.2, 0.822 0.803 290VAC 305VAC 0.46 0.48 AMEPR60-36170AZ (PF) PF VS. Output Current 115VAC, 0.85, 115VAC, 1.7, 230VAC, 0.9960.85, 230VAC, 1 1.7, 277VAC, 0.9650.85, 277VAC, 0.9891.7, 290VAC, 0.9140.85, 290VAC, 0.9741.7, 0.847 0.87 0.46 0.48 115VAC 230VAC 277VAC 290VAC 305VAC F 052.1e R3.AE 7 of 13 North America only

AMEPR60-24250AZ (PF) PF VS. Output Current 115VAC, 1.25, 115VAC, 115VAC 2.5, 230VAC, 1 1.25, 230VAC, 1 2.5, 277VAC, 0.9651.25, 277VAC, 230VAC 0.9892.5, 290VAC, 0.9211.25, 290VAC, 0.977277VAC 2.5, 0.899 0.907 290VAC 305VAC 0.46 0.48 AMEPR60-12500AZ (PF) PF VS. Output Current 115VAC, 2.5, 115VAC, 5, 230VAC, 230VAC, 0.9972.5, 0.997 5, 277VAC, 277VAC, 0.991 5, 0.9612.5, 290VAC, 290VAC, 0.971 5, 0.9062.5, 0.893 0.871 0.46 0.48 115VA C 230VA C 277VA C F 052.1e R3.AE 8 of 13 North America only

PFC Value vs. Output Power AMEPR60-50120AZ 1 0.9 0.8 0.7 0.6 0.5 0.4 0.999 0.991 0.971 0.979 0.901 0.777 90Vac 115Vac 230Vac 264Vac 277Vac 290Vac 305Vac 0.3 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% AMEPR60-24250AZ 1 0.9 0.8 0.7 0.6 0.5 0.4 0.991 0.986 0.984 0.978 0.932 0.802 0.505 90Vac 115Vac 230Vac 264Vac 277Vac 290Vac 305Vac 0.3 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% F 052.1e R3.AE 9 of 13 North America only

Constant Current vs. Constant Voltage Mode AMEPR60-50120AZ Constant Currnet Vs Constant Voltage Vac, 36, 1.2 Vac, 50, 1.2 36 38 40 Vac, 50.4, 0Vac, 52, 0 (V) AMEPR60-36170AZ Constant Currnet Vs Constant Voltage Vac, 24, 1.7 Vac, 36, 1.7 24 26 28 Vac, 36.7, 0Vac, 38, 0 (V) F 052.1e R3.AE 10 of 13 North America only

AMEPR60-24250AZ Constant Currnet Vs Constant Voltage Vac, 12, 2.5 Vac, 24, 2.5 12 14 16 Vac, 24.7, 0Vac, 26, 0 (V) AMEPR60-12500AZ Constant Current Vs Constant Voltage Vac, 5, 5 Vac, 12, 5 5 6 7 Vac, 12.6, 0 Vac, 14, 0 (V) F 052.1e R3.AE 11 of 13 North America only

Dimming Control (Output Current vs. Radj) AMEPR60-50120AZ Output Current VS.Dimming Resistance Vac, 4.037, Vac, 2.333, 1.08 1150.96 & 230 115 Vac, & 1.414, 230 115 Vac, & 0.84 1.015, 230 115 Vac, & 0.72 0.708, 230 115 Vac, & 0.6 0.482, 230 115 Vac, 0.48 & 0.32, 230 Vac, 1150.36 & 0.191, 230 Vac, 0.093, 115 0.24 & 230 0.12 Vac, 0, 0 Vac, 10.69, 1.2 (KΩ) 0 0.093 AMEPR60-36170AZ Output Current VS. Dimming Resistance Vac, 6.35, Vac, 3.16, 1.53 1.36 115 Vac, & 1.93, 230 115 Vac, 1.19 & 1.25, 230 115 Vac, 1.02 & 0.83, 230 Vac, 1150.85 & 0.554, 230 Vac, 1150.68 & 0.354, 230 Vac, 1150.51 & 0.202, 230 Vac, 0.079, 115 0.34 & 230 0.17 Vac, 0, 0 Vac, 36.53, 1.7 (KΩ) 0 0.079 F 052.1e R3.AE 12 of 13 North America only

AMEPR60-24250AZ Output Current VS. Dimming Resistance 0 Vac, 10.3, Vac, 5.07, 22.25 115 Vac, & 3.11, 230 115 Vac, & 1.75 2.096, 230 115 115 Vac, & 1.5 1.42, 230 230 Vac, 115 Vac, 1.25 & 0.666, 0.93, 2301 Vac, 1150.75 & 0.411, 230 115 Vac, & 0.5 0.204, 230 Vac, 0.25 0, 0 Vac, 52, 2.5 0.204 (KΩ) AMEPR60-12500AZ Output Current vs. Dimming Resistance Vac, 20.2, 4.5 Vac, 10.8, 4 115 Vac, & 6.4, 230 3.5 115 Vac, & 4.6, 2303 115 Vac, & 3.1, 2302.5 Vac, 115 2.1, & 230 2 115 Vac, & 1.6, 2301.5 Vac, 115 & 1, 230 1 115 Vac, & 0.43, 230 0.5 Vac, 0, 0 Vac, 50, 5 (KΩ) 0 0.43 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25 C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec s standard Terms of Sale available at www.aimtec.com. F 052.1e R3.AE 13 of 13 North America only