Chapter 2 MODELING AND CONTROL OF PEBB BASED SYSTEMS

Similar documents
2.4 Modeling and Analysis of Three Phase Four Leg Inverter

IMPORTANCE OF VSC IN HVDC

10kW Three-phase SiC PFC Rectifier

Chapter 2 Shunt Active Power Filter

Modeling, Control and Stability Analysis of a PEBB Based DC Distribution Power System

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL

Control Of Shunt Active Filter Based On Instantaneous Power Theory

Current Rebuilding Concept Applied to Boost CCM for PF Correction

Investigation of D-Statcom Operation in Electric Distribution System

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Advances in Averaged Switch Modeling

CHAPTER 2 DESIGN AND MODELING OF POSITIVE BUCK BOOST CONVERTER WITH CASCADED BUCK BOOST CONVERTER

ABSTRACT. Introduction

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

Direct Power Control With Space Vector Modulation And Fuzzy DC- Voltage Control- PWM rectifier

Fundamentals of Power Electronics

Vector Control of Three-Phase Active Front End Rectifier

Improvements of LLC Resonant Converter

U I. HVDC Control. LCC Reactive power characteristics

ABSTRACT I. INTRODUCTION

Lecture 8 ECEN 4517/5517

Simulation And Comparison Of Space Vector Pulse Width Modulation For Three Phase Voltage Source Inverter

Space Vector PWM and Model Predictive Control for Voltage Source Inverter Control

Lecture 41 SIMPLE AVERAGING OVER T SW to ACHIEVE LOW FREQUENCY MODELS

Testing and Stabilizing Feedback Loops in Today s Power Supplies

UNITY POWER FACTOR FRONT END RECTIFIER FOR THREE PHASE INPUT. Controller. Fig. 1 Off-Line Power Supply. Voltage. Sensor A B. Current. Sensor. Fig.

Mathematical Analysis of SVPWM for Inverter fed DTC of Induction motor Drive

CHAPTER 1 INTRODUCTION

SCOTT TRANSFORMER AND DIODE CLAMPED INVERTER FED INDUCTION MOTOR BASED ON FOC

Chapter 1: Introduction

CHAPTER-5 DESIGN OF DIRECT TORQUE CONTROLLED INDUCTION MOTOR DRIVE

Lecture 4 ECEN 4517/5517

A Control Scheme Research Based on Sliding Mode and Proportional-Integral Control for Three-phase Rectifier

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

Chapter 3 : Closed Loop Current Mode DC\DC Boost Converter

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

POWER ISIPO 29 ISIPO 27

5. Active Conditioning for a Distributed Power System

Digital Control Technologies for Switching Power Converters

CHAPTER 4 4-PHASE INTERLEAVED BOOST CONVERTER FOR RIPPLE REDUCTION IN THE HPS

CHAPTER 6 BRIDGELESS PFC CUK CONVERTER FED PMBLDC MOTOR

CHAPTER 7 HARDWARE IMPLEMENTATION

EE595S: Class Lecture Notes Chapter 13: Fully Controlled 3-Phase Bridge Converters. S.D. Sudhoff. Fall 2005

GENERAL OVERVIEW OF HOW POWER ELECTRONICS WORK. Pana Shenoy Calnetix Technologies, LLC Cerritos, CA, USA

CHAPTER 3 MAXIMUM POWER TRANSFER THEOREM BASED MPPT FOR STANDALONE PV SYSTEM

Control of Power Converters for Distributed Generation

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

CHAPTER 3 H BRIDGE BASED DVR SYSTEM

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering Function

Power Factor Correction in Digital World. Abstract. 1 Introduction. 3 Advantages of Digital PFC over traditional Analog PFC.

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

Design and Implementation of a Three-Phase Boost Battery Charger with PFC using CompactRIO Control System

Three Phase Active Power Filter Based on Current Controlled Voltage Source Inverter

ELEC387 Power electronics

VOLTAGE MODE CONTROL OF SOFT SWITCHED BOOST CONVERTER BY TYPE II & TYPE III COMPENSATOR

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

A Static Synchronous Compensator for Reactive Power Compensation under Distorted Mains Voltage Conditions

CHAPTER 6 CURRENT REGULATED PWM SCHEME BASED FOUR- SWITCH THREE-PHASE BRUSHLESS DC MOTOR DRIVE

AVERAGE CURRENT MODE CONTROL IN POWER ELECTRONIC CONVERTERS ANALOG VERSUS DIGITAL. K. D. Purton * and R. P. Lisner**

CHAPTER 4 FUZZY BASED DYNAMIC PWM CONTROL

BUCK Converter Control Cookbook

A novel method to improve Power quality by using wind and solar hybrid system

Chapter 10: Compensation of Power Transmission Systems

A Comparative Study between DPC and DPC-SVM Controllers Using dspace (DS1104)

Literature Review for Shunt Active Power Filters

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

A Predictive Control Strategy for Power Factor Correction

Chapter 6. Small signal analysis and control design of LLC converter

Lecture 4 - Three-phase circuits, transformer and transient analysis of RLC circuits. Figure 4.1

Digital Control of Permanent Magnet Synchronous Motor

ANFIS based 48-Pulse STATCOM Controller for Enhancement of Power System Stability

CHAPTER 4 CONTROL ALGORITHM FOR PROPOSED H-BRIDGE MULTILEVEL INVERTER

Power Quality Improvement using Shunt Passive Filter

POWER- SWITCHING CONVERTERS Medium and High Power

CHAPTER 3 CASCADED H-BRIDGE MULTILEVEL INVERTER

Unified Power Quality Conditioner based on an Indirect Matrix Converter with a PV panel

Power Quality Improvement of Non-Linear Load by Using Instantaneous P-Q Theory

Power Management for Computer Systems. Prof. C Wang

PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT CARRIER AND MODULATING SIGNAL

CHAPTER 3 VOLTAGE SOURCE INVERTER (VSI)

A Novel Concept in Integrating PFC and DC/DC Converters *

User Guide Introduction. IRMCS3043 System Overview/Guide. International Rectifier s imotion Team. Table of Contents

CHAPTER 4 PI CONTROLLER BASED LCL RESONANT CONVERTER

CHAPTER 2 VSI FED INDUCTION MOTOR DRIVE

Demonstration. Agenda

LECTURE 40 Introduction to Converter Dynamics A. AC Model Construction 1. Actual Switch mode Non-Linear System 2. Small AC Models by two Analytical

NEUTRAL CURRENT COMPENSATION USING FOUR LEG SHUNT ACTIVE POWER FILTER

Experiment 4: Three-Phase DC-AC Inverter

Investigation of negative sequence injection capability in H-bridge Multilevel STATCOM

ISSN: [Kumaravat * et al., 7(1): January, 2018] Impact Factor: 5.164

Fig. 1 Schematic Diagram Showing Connections to the Active Filter With Non-Linear Load

Chapter-5 MODELING OF UNIFIED POWER FLOW CONTROLLER. There are a number of FACTS devices that control power system

Chapter 33. Alternating Current Circuits

Real and Reactive Power Control by using 48-pulse Series Connected Three-level NPC Converter for UPFC

Final Exam. Anyone caught copying or allowing someone to copy from them will be ejected from the exam.

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

Transcription:

Chapter 2 MODELING AND CONTROL OF PEBB BASED SYSTEMS 2.1 Introduction The PEBBs are fundamental building cells, integrating state-of-the-art techniques for large scale power electronics systems. Conventional power electronics systems lack high degree of integration and standardization. PEBBs help to standardize and simplify the design process. Instead of working with components, designers work at block level and this greatly reduces the design effort. Chapter 2 7

This chapter will discuss the modeling and control of systems built using modular PEBBs. Compared to the conventional systems, a PEBB based system offers advantages like system reconfiguration, hierarchical control and control intelligence. To demonstrate these ideas, a PEBB based Boost Rectifier and a Four Leg Inverter system is analyzed in this chapter. Section 2.2 discusses the three level modeling approach adopted, which is applicable for analyzing all PEBB based systems. The PEBB switching cell has been identified in the previous section. Figure 2.1(a) shows three PEBB switching cells configured to form a Boost Rectifier. The Boost Rectifier converts three phase input voltage to regulated DC link voltage. Section 2.3 describes the modeling and control of the Boost Rectifier. Figure 2.1(b) shows a three phase Four Leg Inverter composed of four PEBB switching cells. Section 2.4 describes the modeling and control of the four leg inverter. The Four Leg Inverter converts DC link voltage to provide utility power. As compared to a conventional three phase inverter, it can provide balanced three phase output voltage even in presence of unbalanced and non-linear load [7]. Each of these PEBB based converter is designed for stability and good transient performance. The PEBB based systems employ digital controllers like Digital Signal Processors (DSP) and the feedback control loop is implemented digitally using the DSP. As compared to analog controllers, digital controllers allows flexibility in system operation and system configuration. It is described in detail in later sections. Chapter 2 8

PEBB Vo 3φ F I L T E R ia ic L O A D CONTROLLER (a) Front End Boost Rectifier PEBB Output Filter Nonlinear Unbalanced Load Vdc F I L T E R L L N C Vφ CONTROLLER (b) Three Phase Four Leg Inverter Figure 2.1 PEBB based Boost Rectifier and Inverter system Chapter 2 9

2.2 Modeling Approach The PEBB-based converters are modeled and simulated using SABER. A three level modeling approach is employed and three models were developed in SABER namely, Discrete Switching model, Average Large Signal model and the Small Signal model. In the Discrete model, the power stage of the converter is modeled using ideal switches. The DSP based digital controller is modeled using MAST, a Hardware Description Language available in SABER. The Discrete model using ideal switches gives descriptive information regarding system behavior such as voltage and current switching ripple. This information is useful in the design and analysis of input EMI filter for Rectifier and VSI. Its main drawback is long simulation time and also it does not give any insight to controller design. The Average Large Signal model is derived from the switching model using time averaging equivalent circuit approach [8]. It results in a time-invariant model which is valid at frequencies much lower than the switching frequency. Process of averaging removes the switching action of the switches in the power stage. It can be used to predict the system performance with greatly reduced simulation time. The average model in the stationary coordinates is transformed to obtain average model in rotating co-ordinates. This results in system variables which are DC quantities. The Average Large Signal model is perturbed and linearized around an operating point to get the Small Signal model. Based on the derived Small Signal Model, control loop design guidelines are obtained. Chapter 2 10

2.3 Modeling and Control of Front End Boost Rectifier The three phase Boost Rectifier, as shown in Figure 2.1(a), is an attractive topology for use as a front-end power processing unit at higher power levels. It converts three phase input voltage to regulated DC link voltage. Also, it provides unity Power Factor and draws continuous input currents [5],[6]. As shown in Figure 1.2, the three phase Boost Rectifier is used in the shipboard DC DPS to provide regulated DC link voltage. In this section, the modeling and control of PEBB based rectifier is described. An analog controller based Boost Rectifier switching model has been discussed in the literature [9]. A DSP processor based Boost Rectifier switching model is presented in this section. Also, the fault tolerance capability of a PEBB based Boost Rectifier is studied. 2.3.1 Principle of Operation Figure 2.2 shows the three phase Boost Rectifier composed of PEBBs. Three PEBB cells with integrated gate drives are configured to form the Boost Rectifier power stage. A DSP based local controller supplies gate drive commands through a DSP interface board. The feedback control loop is implemented digitally using the DSP. The PEBB system also includes a sensor board which senses the DC link voltage, AC voltage and current and provides feedback to the local controller. The system level control in the PEBB based power Chapter 2 11

distribution is hierarchical. The local-controller has communication ports to communicate with the zonal-level controller or the host computer. The local controller is field programmable to implement the desired control strategy. Figure 2.3 shows the Discrete switching model of the DSP controlled boost rectifier simulated using SABER. For the DC DPS application, this model serves as an important tool to observe the effect of switching ripple on the DC link and also helps in the design of input EMI filter. The PEBB cells are modeled as ideal switches with anti-parallel diodes. The rectifier has an inner current controller in rotating co-ordinates and an outer voltage loop. The DC link voltage is sensed and compared to the voltage reference. The error voltage is passed through a compensator to generate I dref (I d current reference), as the d-channel is responsible for the power transfer. The d-q co-ordinates axis are aligned with respect to the input line voltages such that V q =0. As a result, the q channel current reference, I qref is set to zero in order to achieve unity power factor [5]. The input line currents are sensed and converted from stationary co-ordinates to rotating co-ordinates to generate I d and I q. The transformation T, from stationary to rotating co-ordinates is explained in Appendix C. The inner current controller has compensators, H id and H iq in d and q channels. The output of the current controller are the switch duty cycles d d and d q. These duty cycles, d d and d q are transformed from rotating to stationary co-ordinates to generate dα and d β. Space Vector Modulation (SVM), as explained in Appendix B is used in distributing the duty cycles [17]. Chapter 2 12

Vo 3φ F I L T E R ia ic L O A D Sensor Board Driver Driver Driver V DC V ac,i ac DSP Interface Board DSP (I,V Loop, PWM Generation) Hierarchical Control (Host Computer) Figure 2.2 : PEBB based Three Phase Boost Rectifier : Three PEBB cells with integrated gate drives are configured to form the Boost rectifier. The DSP based local controller communicates with the host computer. Chapter 2 13

PEBB1 PEBB2 PEBB3 Vo VAB Input ia VCA EMI ib a b c Co VBC Filter ic Control abc dq Id Iq d0 d1 d2 SVM dd Gate Drive dα dβ abc dq dq Current Controller dq coordinates Idref gating signals Voltage Comp Vref Iqref = 0 Figure 2.3 : Discrete Switching Model of the Boost Rectifier : It provides time domain information. The boost inductor currents and the DC link voltage are sensed and fed to the compensator. The controller is shown in the dotted box. Chapter 2 14

2.3.2 Power Stage Modeling The Average Large Signal model of the boost rectifier is derived using time averaging equivalent circuit approach [6]. It results in a time-invariant model which is valid at frequencies much lower than the switching frequency. Figure 2.4 shows the Average Large Signal Model. Six switches in the power stage are replaced with three controlled voltage sources and a controlled current source. The output stage of the power converter remains the same. The controlled voltage and current sources in the Average model are represented as : V V V ab bc ca = d d d ab bc ca V 0 and, I p = [ d d d ab bc ca ] I I I ab bc ca Where d ab =(d a -d b ), d bc =(d b -d c ), d ca =(d c -d a ) are the control duty cycles And, d i (i=a,b,c) are duty cycle of the upper switch in i th leg. Also, I ab =(I a -I b )/3, I bc =(I b -I c )/3, I ca =(I c -I a )/3 Where, I a, I b, I c are the input phase currents Chapter 2 15

ia Ip Vo VCA VAB ib L a b c C Io Rload VBC ic Averaging VCA ia VAB ib VBC L ia ib vab vbc iab ibc vca ica Ip C Vo Io Rload ic ic Figure 2.4 : Average Large Signal Model in Stationary Co-ordinates : The process of averaging replaces the switches with controlled voltage and current sources. Chapter 2 16

The complete model in stationary co-ordinates is given by : d dt I I I ab bc ca = V 1 V 3L V AB BC CA d 1 d L d ab V 3 bc 0 ca [ ab bc ca ] d dt V 1 = C d d d I I I ab I 0 bc 0 ca The rectifier draws sinusoidal input current and maintains unity power factor. Thus, it is evident from Figure 2.4 that the controlled voltage sources V ab, V bc, V ca must be sinusoidal in the average sense. Since V 0 is a constant, this further implies that the desired control duty cycles d ab, d bc, d ca must be sinusoidal. Figure 2.5(a) gives the line-line voltage V ca in switching model and average model. V ca is pulse width modulated in the switching model and is a sinusoid in the average sense. Figure 2.5(b) gives the output DC rail current in the two models. The average model gets rid of the switching ripple and yields the average value of voltage and currents. These values can be controlled to get the desired output. As the steady state duty cycle in the Average Model are sinusoids, conventional feedback control techniques cannot be used. Therefore, the transformation T, as explained in Appendix C is applied to the Average Model to produce an Average Model in rotating Chapter 2 17

(a) Line-Line voltage V ca (b) Output DC rail current Figure 2.5 : Waveforms in switching and average models : The average model gets rid of the switching ripple and yields the average value of the waveforms. Chapter 2 18

co-ordinates. Figure 2.6 gives the power stage expressed in d-q co-ordinates. The desired steady state duty cycles are DC quantities and this makes it easier to design feedback controllers. It is explained in detail in section 2.3.3. The Boost Rectifier is represented in rotating co-ordinates as : V V d q L di d = 3 dd V 0 + 3ωL i dt L di q = 3 dq V 0 3ωL i dt q d 3 d d C dv o ( d i d + q i q ) = I 2 dt o The d-q reference frame is aligned with the input line-line voltages such that V d = V m ( Max. line-line voltage), and V q = 0. There is coupling between the d and q subcircuits. The steady state variables in the d-q model are DC quantities. The average large signal model of the boost rectifier, as shown in Figure 2.6, is perturbed and linearized at an operating point to get the small signal model (Figure 2.7). The small signal model is used for frequency domain analysis. The DC operating point is given by Dd, Dq, Vo, Id, Iq. The power stage yields open loop transfer functions namely, V 0 /d d, V 0 /d q, i d /d d, i d /d q, i q /d d, i q /d q. These transfer functions are valid upto half the switching frequency. Figures 2.8(a),(b) gives the open loop transfer functions V 0 /d d and V 0 /d q respectively. These transfer functions are useful for closed loop controller design. Chapter 2 19

3L id 3wLiq Fd Fq vo abc Va Vd Vb iq dd*vo Co R Vc dq Vq = 0 3L 3wLid dq*vo Fd = 3/2 dd*id Fq = 3/2 dq*iq Figure 2.6 : Average Large Signal Model in Rotating Co-ordinates : Applying the transformation T, results in the d-q model. It also results in coupling between the d and q sub-circuits shown as two voltage sources. Chapter 2 20

3L id 3wLiq Gd Gq Fd Fq Vo vd ddvo + Ddvo Co R vq = 0 3L iq 3wLid dqvo + Dqvo Gd = 3/2 Dd * id Gq = 3/2 Dq * iq Fq = 3/2 dq * Iq Fd = 3/2 dd * Id Figure 2.7 : Small Signal Model in Rotating Co-ordinates : The Average Large Signal Model is perturbed and linearized at an operating point to yield this model. Chapter 2 21

(a) Plot of V 0 /d d (b) Plot of V 0 /d q Figure 2.8 : Control-to-Output Voltage Transfer Function of the d & q channel : The transfer function V 0 /d d has a complex pole around 1.2kHz and has a right half plane zero. The presence of right half plane zero deteriorates the phase of the system. The transfer function V 0 /d q is similar to V 0 /d d. Chapter 2 22

2.3.3 Control Loop Design The small signal model of the rectifier is utilized to design compensators. The power stage is in d-q co-ordinates and the controller is implemented in d-q co-ordinates. Figure 2.9 gives the structure of the controller. It has an inner current loop and an outer voltage loop. The inner current controllers are Hi d and Hi q and H v is the outer voltage loop compensator. I qref is set to 0, as the input currents are supposed to be in phase with supply voltage and V q is taken as 0. The d-channel transfers power to the output and the output of the voltage compensator H v provides d-channel current reference. As shown in Figure 2.9, the d and q channels in the power stage are coupled and the coupling is shown by the dotted arrows. As a result, it is not possible to control the d and q channels independently. Thus, the coupling in power stage is canceled by changing the current controller, as shown in Figure 2.10 (a). A cross-coupling term 3ω L/ V 0 is introduced in both d and q channel outputs such that they cancel the coupling in the power stage. Figure 2.10 (b) shows the de-coupled power stage. Now, it is possible to design the compensator for the 2 channels independently resulting in a better performance. Digital implementation of the current controller introduces a sampling delay, as discussed in [5]. The delay yields 180 0 phase lag at half the switching frequency and must be taken into account. Chapter 2 23

Va abc Vd 3L id 3wLiq Fd Fq vo Vb iq dd*vo Co Vc dq 3L Vq = 0 3wLid dq*vo Fd = 3/2 dd*id Fq = 3/2 dq*iq dd id vo dq Hid iq idref Hv Vref Hiq iqref = 0 Figure 2.9 : Controller Structure as applied to Average Large Signal Model : The coupling in the power stage is shown by the dotted arrows. It shows that d and q channels cannot be controlled independently. Chapter 2 24

idref Hv Hid dd Vo id iq 3 w L Vo 3 w L Vo iqref Hiq dq (a) Coupling in inner current controller id 3L 3wLiq 3wLiq Vo Vd iq 3L 3wLid dd*vo 3wLid 3/2dd*id 3/2 dq*iq Co L O A D Vq dq*vo (b) De-coupled Power Stage Figure 2.10 : Controller Structure incorporating Decoupling : The new controller structure, shown in (a) includes a factor which decouples the power stage, as shown in (b). Chapter 2 25

The digital delay is given by: e st 1 s T = 12 1 s T 12 2 2 2 2 05. st + 1 + 05. st + 1, where T = Sampling Time The current compensators Hi d and Hi q are implemented as proportional gain. The inner loop gain is limited to half the switching frequency due to the sample and hold delay. Design of the compensators depend on direct transfer functions id/id ref, iq/iq ref. The compensators Hi d and Hi q are chosen such that the transfer functions id/id ref, iq/iq ref are unity till the inner current loop bandwidth. The transfer function V 0 /id ref, shown in Figure 2.11(a) is used to design the outer loop compensator. Fig. 2.11 (b),(c) gives the plot of iq/iq ref. It can be seen that it has a wide bandwidth and that iq follows iqref at low frequencies. Plot of id/id ref is also similar. Fig. 2.11 (d),(e) gives the outer loop gain T V = (V 0 /id ref )*H V. The compensator is implemented as a proportional and integrator compensator as it ensures zero steady state error. The loop gain is adjusted to get good phase margin. The q channel control to inductor current transfer function is designed to be unity upto the current bandwidth i.e. 2 khz. The outer loop gain Tv has a bandwidth of 1 khz and phase margin of 50 0. Chapter 2 26

(a) Transfer function V 0 /id ref (b) (c) (d) (e) Figure 2.11 a-e :Closed Loop Transfer Functions of the Rectifier (a) V 0 /id ref plot (b) iq/iqref magnitude plot (c) iq/iqref phase plot (d) Tv magnitude plot (d) Tv phase plot. Chapter 2 27

2.3.4 Simulation Results The three phase boost rectifier, shown in Figure 2.3, is designed to supply 15 kw output power and ensure PFC. The power stage parameters are given in Appendix A. The controller parameters are designed as described in section 2.3.3. An EMI filter is used to reduce the switching spikes in the input phase current. The Discrete Switching model was implemented using SABER and MAST. Figure 2.12 (a) shows the regulated output DC link voltage. The output voltage is regulated to 400V. The switching frequency ripple information can be obtained from it. Fig. 2.12 (b) shows the balanced three phase input current drawn by the rectifier. Proportional compensators were used in the current loop and proportional-integral compensators were used in the outer voltage loop to ensure zero steady state error. The switching frequency employed was 40 khz. The bandwidth of the outer loop is 1 khz and it has a phase margin of 50 degrees. Figure 2.12 (c) shows the input EMI filter to the rectifier [9]. The filter is designed to reduce the switching ripple from the current drawn by the rectifier. Figure 2.12 (d) shows the current drawn by the EMI filter and it is in phase with the input phase voltage. The input current drawn by the EMI filter is smooth and devoid of any switching ripple. The EMI filter draws reactive current and causes phase shift between the input supply voltage and current. In order to compensate the phase shift caused by the input filter [10], Iqref value is chosen so as to cancel the reactive current drawn by the input filter in steady state. Chapter 2 28

(a) Output DC Link Voltage (b) Input current drawn by the rectifier 50 u 0.35 u 0.9 u 2 Ω 18 u Va 3.4 u 5.7 u 17 u 20 u 4.8 u ia (c) Input EMI Filter (d) Input Phase Current & Voltage Figure 2.12 : Simulation Results of 15 kw Rectifier with Input EMI Filter : The switching frequency employed was 40 khz.. Chapter 2 29

2.3.5 Fault Tolerance The PEBB based system has the ability to reconfigure the system operation and maintain power flow in case of a fault condition. The conventional system suffers from the drawback that if one of the legs of the rectifier switches fails then the system has to be shut down. Thus we need to have redundancy in the system and this increases the cost of the system. The typical fault condition in a DC DPS system occurs as a result of failed semiconductor switches either short circuited or open circuited. This fault condition is analyzed in this section. Figure 2.13 shows the configuration of the system composed of PEBBs. The mid point of the split dc link is connected to the supply neutral through a switch. The switch is normally open and is closed in case of a fault in one of the legs of the rectifier. Figure 2.14 shows the configuration of the system with leg c of the rectifier failed open circuited. The neutral connection is closed and the local controller commands the current controller to change the control strategy. As the inner controller is implemented digitally, it is a matter of implementing a sub routine in the DSP which changes the control strategy. As discussed in section 2.3.1, the controller is implementing Space Vector Modulation (SVM) control. SVM control involves current controller in rotating co-ordinates and cannot be implemented when one phase fails. As shown in Figure 2.15, the controller achieves PFC for the remaining 2 phases by using proportional - integral compensators for Chapter 2 30

VA ia ic neutral Controller Figure 2.13 : Rectifier Configuration in Normal Operation Mode: The midpoint of the DC link has a connection to the supply neutral. The switch is open during normal operation mode. Chapter 2 31

Vo VA ia ic=0 neutral Gate Drive SVM Vref wt Current Controller Idref Iqref Control intelligence Voltage Comp ZONAL CONTROL Figure 2.14 : Rectifier Configuration with Phase c Open Circuited: The rectifier is assumed to have a fault with phase c open circuited. The controller closes the switch in neutral wire.. Chapter 2 32

the inner current loop. The rectifier supplies the same rated output power by drawing 1.5 times more phase current. The control intelligence ensures that the output gate pulses are provided to the two healthy phases. The control strategy is changed to output correct gate pulses. Figure 2.16 (a)-(d) show the simulation results for the reconfigured system during fault mode. Figure 2.16 (a) shows the input current drawn by the two active legs of the rectifier. Figure 2.16 (b) shows the current carried by the neutral wire. Figure 2.16 (c) shows that PFC is obtained for the remaining 2 phases. Figure 2.16 (d) shows the regulated DC link voltage. The output DC link has a low frequency oscillation due to charging of the capacitors by the neutral current. Thus, capacitance of the order of 1mF is needed to reduce the output voltage ripple on the DC link. The disadvantage of the scheme is that the neutral wire carries a large current and the phase current increases to 1.5 times the normal value. But, the system is stable and can operate for the transition time till the fault is cleared away. Chapter 2 33

Vo VA ia ic=0 neutral PWM PWM V ref PI PI K p K + s i cos( ωt 120 0 ) cos( ωt) Current Reference Figure 2.15 : Reconfigured Controller Structure : The control algorithm changes such that instead of SVM technique, the two healthy phases are controlled independently with an inner current loop and a common outer voltage loop. Chapter 2 34

(a) Phase currents ia, ib (b) Neutral current Va ia (c) Phase current (i a ) and phase voltage (v a ) (d) Output DC rail voltage Figure 2.16 : Simulation Results for 15 kw Rectifier under fault mode operation The rectifier is stable after system reconfiguration. The healthy phases carry 1.5 times the rated current. The output DC link has a low frequency oscillation due to the charging of the capacitors by the neutral current. Chapter 2 35