CHARGER REV 01 HGPOWER SPECIFICATION. Edition No.: 01 HGP-CH08 CHARGER

Similar documents
Product Specification sheet

APPROVAL SHEET 12V/2A EA1019HHUS(03) EA1019HHUS-120 APP D EDAC POWER ELECTRONICS CO., LTD. TEL: FAX:

RoHS APPROVAL SHEET. ituner 12V/5A SERIES NO. (05) EA10523C-120 CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0

ST-250MAK-05E. Switching Power Supply SPECIFICATION

SC72-220S24 Technical Specification

TC-600PD2. Switching Power Supply ( 600W PS2 ATX12V ) SPECIFICATION. Revision: 1.0

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

LB115S 115W Single Output

SPECIFICATION. SilverStone OLYMPIA OP1000 Switching Power Supply Active PFC

UMEC SMPS SPECIFICATION

SFX Form Factor SST-SX650-G SST-SX500-G. The standard SFX power supply benchmark

Doc. EA Model Number:

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

APPROVAL SHEET I TUNER 12V/10.83A EA11703A(01) EA11703A-120 APP D EDAC POWER ELECTRONICS CO., LTD. TEL: FAX:

Technical Data SM10-24 Single Output Series of Power Modules

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

SPECIFICATION FOR APPROVAL

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

HEC-100RTA-48QSCA Rev A1.0

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

11SP 4247 LCD TV Power specification Rev 1.3 Specification

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

50W Constant Current (700mA) Dimming LED Driver

MB120S 120W Single Output Medical Series

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

Specifications 2016-V AC-DC Switching Mode Power Supply NK-200 Series, 200W

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

Model Number Output V1/V2/V3 Output I1/I2/I3 max. Ripple & Noise Efficiency(min/nom) Capacitive Load

75W Constant Current (700mA) LED Driver

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

VP ELECTRONIQUE MASSY - Tel:

AC-DC Switching Power Module CFM61S Series APPLICATION NOTE

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Specifications 2019-V AC-DC Switching Mode Power Supply NK-100 Series, 100W

VOF XX - XXX - X

TB65 65W Single Output Test and Measurement/Industrial Series

AC/DC Converter LB(05-25)-10BxxLT Series

15 W DC/DC CONVERTERS. SERIES DESCRIPTION Page. PC15WR 2:1 Input Range 2 2 x 1 Metal Can Package 2kv Isolation

18093-PS PHIHONG TECHNOLOGY CO., LTD. General Specification PSM (DC)

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Always there to help you. Register your product and get support at AJ3232. Question? Contact Philips.

SPECIFICATION FOR APPROVAL

PSU s e r i es

Typical Efficiency (2) 22~36 Vdc 25 W 84% LUC-024S070DSW(SSW) (3) 15~24 Vdc 25 W 83% LUC-024S105DSW(SSW) (3)

TC-2U70PD8. Switching Power Supply ( 2U 700W 80PLUS) SPECIFICATION. Revision: 2.0

VLM60/40 Series. 60 & 40 W, Efficient, Compact Constant Voltage Class 2 LED Drivers

REDUNDANT AC 300W POWER SUPPLY. Technical Specifications TD-AC-300W-MAX

PF 0.96/230VAC PF 0.96/115VAC at full load and rated output voltage PF 0.9 at 60 ~ 100% load INPUT EFFICIENCY (Typ.)

24V 40A 0 ~ 40A 960W. 150mVp-p 20 ~ 26.4V 83% 85% 88% 88% 90%

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Always there to help you. Register your product and get support at AJ4300. Question? Contact Philips.

Line Reg Load Reg Ripple Efficiency *Model Number Output V Output I (nom/max) (nom/max) & Noise (min/nom)

TC-750PD8. Switching Power Supply ( PS2 ATX750W 8 0 PLU S ) SPECIFICATION. Revision: 1.0

TE W Single Output External Power Test & Measurement/Industrial Series

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

TE60 60W Single Output External Power Test & Measurement/Industrial Series

HEC-40LTN-XXPSCA Rev A

HEC-30/35LTA-33TDAA Rev A

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

HEC-35LTA-XXTSAA Rev A

TE60 60W Single Output External Power Test & Measurement/Industrial Series

DIGITAL RADIO INCLUDING FM, DAB AND DAB+

SPECIFICATION FOR APPROVAL

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

HLG HLG HLG HLG HLG HLG HLG HLG HLG

SPECIFICATION ARP

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 428 Vdc 150 W 93.5% EUC-150S035DT

REDUNDANT DC 200W POWER SUPPLY. Technical Specifications TD-DC-200W-12V

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

AC-DC Switching ADAPTER TRE25R VI Series APPLICATION NOTE

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

3 0 W U l t r a m i n i a t u r e O p e n F r a m e S w i t c h i n g P o w e r S u p p l i e s E F M 3 0 s e r i e s

HEC-45LTN-45PFAS Rev A

SPECIFICATION SilverStone ST30NF for Standard Switching Power Supply With Active PFC PS/2 Fanless 300W

MODEL: M2DYS SEN TRONIC AG

TE90 90W Single Output External Power Test & Measurement/Industrial Series

HLG-185H-12 HLG-185H-15 HLG-185H-20 HLG-185H-24 HLG-185H-30 HLG-185H-36 HLG-185H-42 HLG-185H-48 36V 18 ~ 36V 13A 11.5A 9.3A 7.8A 6.2A 5.2A 4.4A 3.

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

42V 21 ~ 42V 4.8A 4A 3.2A 2.65A 2.28A 30V 15 ~ 30V. 200mVp-p 27 ~ 33V. Can be adjusted by internal potential meter or through output cable

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

HLG-150H-12 HLG-150H-15 HLG-150H-20 HLG-150H-24 HLG-150H-30 HLG-150H-36 HLG-150H-42 HLG-150H-48 12V

SPECIFICATION AC/DC ADAPTOR. CUSTOMER SPEC:INPUT: V AC 50/60Hz OUTPUT:24VDC500mA SAMPLE NO: REV.: B ISSUE DATE:

HLG-240H-12 HLG-240H-15 HLG-240H-20 HLG-240H-24 HLG-240H-30 HLG-240H-36 HLG-240H-42 HLG-240H-48 12V 36V 18 ~ 36V 16A 15A 12A 10A 8A 6.7A 5.

AC/DC Power Supply Single-Output

300W AC-DC Power Supply with PFC CFM300M Series APPLICATION NOTE

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

PDAM500 Series 500W Power Supply

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

240W Single Output Switching Power Supply SELV

TE40 40W Single Output External Power Test & Measurement/Industrial Series

DC-DC LED DRIVER WITH DALI INTERFACE MODULE ALD-D SERIES

HRS50 Series 50W isolated DC/DC converters

AC-DC ITE & Medical Switching Power Supply

AZATOM SONANCE T1 Digital Radio. DAB+/DAB/FM Radio Alarm Clock. User Manual. This manual is available to download online at

SXN15 48V SERIES. Dual output TÜV. High Efficiency DC/DC Converters

Transcription:

SPECIFICATION Edition No.: 01 HGP-CH08 CHARGER Draft Auditing Authorize Date Date Date Customer confirm Date: Changzhou Hongguang Electron Co.,LTD Date: 2007-06-18 Add: Banshang Lijia Town Changzhou City Jiangsu China Tel : 86-519-6732495,6732139-8005 Fax: 86-519-6731270 www.hgpower.com E-mail:lglxdh@public.cz.js.cn

Modify Record Product Name Model Mobile phone charger HGP-CH08 Modify: Edition. 01. 02. 03. 04. 05. 06. 07. 08. 09. A B C D E Edition No. Modify Date Perform Date Modify Content Deviser Confirm Auditing

TABLE OF CONTENTS 1. Scope 2. Connecting form 3. Electrical requirements 4. Environmental requirements 5. Safety requirements 6. EMI requirements 7. Instruction for safety usage 8. Radiation 9. Conduction 10.Attached picture

1 Scope This is the engineering specification of mobile phone charger, this charge has a wide voltage 100~240V AC input and single output 5V DC with USB port, packaged into a models covered. Model: HGP-CH08 2 Connecting form The input and output port connect style: 2.1 Input connector Two sheet copper socket connector 2.2 Output connector USB/A output port. 1.2 meters output cord with four pins one end and USB/5P the other end. Picture is attached,please check.

3 Electrical requirements (Unless specified otherwise, all specifications are at nominal input voltage, full load, 25, PSU at warmed up condition.) 3.1 Input The operating conditions with respect to the AC input voltage are described in this section. 3.1.1 Input Voltage Input voltage range: 90~264VAC Work voltage range: 100~240VAC 3.1.2 Input Current When work on normal condition, the highest input current is less than 0.1A. 3.1.3 Input Frequency Input frequency: 50/60HZ 3.1.4 Inrush Current At 264VAC,the maximum inrush current is less then 20A. 3.1.5 Efficiency The average efficiency is larger then 50%. 3.1.6 Standby power At 100Vac~240Vac input voltage, the maximum standby power is 0.3W. 3.2 Output 3.2.1 Rated output voltage Rated output voltage is DC5.0V+/-5%,that is DC4.75V~5.25V. 3.2.2 Rated output current Rated output current DC680mA, the range DC630 ma~730ma. 3.2.3 Output ripple and noise voltage At rated current load, the maximum ripple is less than 200mV. (Measure condition:20mhz bandwidth,parallel a 0.1uF ceramic capacitor and a 47uF electrolytic capacitor at the oscillograph port). 3.2.4 Output speciality curve Vout V(DC) 630 730 Iout ma

3.2.5 Turn-on delay Turn-on delay time is measured from the charger turn on to the input and output voltage reach the allowed rang. At AC100V, the turn-on delay time is less than 2 seconds. 3.2.6 Output hold up time The charge shall maintain its output voltage and current more than 10ms when cut off it s AC input voltage. Measured at normal input voltage of 100~240VAC and with a mutative load large than 50%. 3.2.7 Output protection Short circuit protection: the charger will be protected against output short circuit and will self recover after short circuit eliminated. Over current protection: the charger will be protected when output current over 1.5A and will resume work after eliminate the fault. Over voltage protection: the charger will be protected if any component invalidate. Measured method:cut the sampling resistor and change a 10K adjustable resistor,then modulate output voltage till it reach the highest value.

4 Environmental Requirements 4.1 Temperature Opetate temperature: -10 ~40 Storage temperature: -25 ~70 4.2 Altitude Maximum operate altitude 3000 feet Maximum storage altitude 10000 feet 4.3 Humidity Non-condensing relative humidity range: 5%~95% 4.4.1 Vibration The charger shall meet operating and non-operating. Vibration Frequency Acceleration Two time Cycles Operating 5-500Hz 0.5G 15min,xyz all 15min 2 Non-operating 5-500Hz 1G 15min,xyz all 15min 2 4.4.2 Falling On concrete ground Falling Height Direction Cycles Non-operating 1.0m xyz,all 2 times 6 4.5 Input inrush voltage Minimum dielectric AC-line inrush voltage : Between AC input L to N: Inrush Tr /Td Voltage Phase Time Cycles Operating 1.2us/50us 1.0KV 0 1min 10 90 10 270 10 360 10 4.6 Antistatic strength Contact discharge 4KV Air discharge 8KV

5 Safety Requirements 5.1 Withstand Voltage Minimum withstand voltage between input and output is AC3KV with stand time 1 minute, and leak current is less than 5mA. 5.2 Leakage Current Minimum leakage current from primary to secondary shall less than 0.25mA at input voltage AC264V. 5.3 Insulation Resistor Minimum insulation resistor from primary to secondary shall be more than 100MΩ at voltage DC500V. 5.4 Safety Spacing Minimun 6.5mm between primary and secondary. 5.5 Safety Standard Approval Meet CCC approval. 5.6 Reliability MTBF: min 50000 hours, at 25, input voltage 240VAC,output current is the 3/4 of rated current. 6 EMI Requirements EMI standard: EN55022 and EN55024.

7 Instruction For Safty Usage IMPORTANT SAFETY INSTRUCTIONS Usage Note: 1. Caution! This sign warns there are rishs of electric shock. 2. Warning! This sign warns there are important safety parts and Hi-Voltage together with the product. 3. Indoor!. This sign warns that the product can only be used indoor. For avoiding static shock or high-voltage arc, please use wide-notch socket & insert the plug into the socket completely. For Power Supply working reliable please be sure the socket must be suitable for the output plug and insert them tightly. Please always keep the Power Supply at ventilating place; otherwise it will enter into protecting situation. Warning: Do not install this power supply in a confined space such as a book case or similar unit. There is no switch in the product. The mains plug or appliance coupler is used as disconnect device, it shall be easily accessible. No naked flame sources, such as lighted candles. Should be placed on the apparatus. Do not exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus. The product is suitable to be used in moderate climate, do not use it in tropics. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus. Caution! : Pease don t use AC voltage which not in the range of 100-240V, otherwise the Power Supply may be damaged. When pull the plug out from the socket, please hold its base but never pull it by draw its wire, as the wire may be broken or damaged to course short circuit & fire.

8. Radiation CPCEMC EMI TEST Electric Field Strength EUT: Manufacturer: Operating Condition: Run Test Site: 10m Radiated Emission Chamber Operator: xbrong Test Specification: Horizontal AC:230V/50Hz Comment: M/N: HGP-CH08 Start of Test: 6/23/2007 / 08:07:47 SCAN TABLE: "EN 55022 Field fin" Short Description: EN 55022 Field Strength fin Start Stop Step Detector Meas. IF Transducer Frequency Frequency Width Time Bandw. 30.0 MHz 1.0 GHz 80.0 khz QuasiPeak 1.0 ms 120 khz HL 562 UltraLog 80 Level [db 礦 /m] 70 60 50 40 30 20 10 0 30M 50M 70M 100M 200M 300M 500M 700M 1G Frequency [Hz] MES 70186F1H_pre PK LIM EN 55022 F QP Field Strength QP Limit

CPCEMC EMI TEST Electric Field Strength EUT: Manufacturer: Operating Condition: Run Test Site: 10m Radiated Emission Chamber Operator: xbrong Test Specification: Vertical AC:230V/50Hz Comment: M/N: HGP-CH08 Start of Test: 6/23/2007 / 08:01:19 SCAN TABLE: "EN 55022 Field fin" Short Description: EN 55022 Field Strength fin Start Stop Step Detector Meas. IF Transducer Frequency Frequency Width Time Bandw. 30.0 MHz 1.0 GHz 80.0 khz QuasiPeak 1.0 ms 120 khz HL 562 UltraLog 80 Level [db 礦 /m] 70 60 50 40 30 20 10 0 30M 50M 70M 100M 200M 300M 500M 700M 1G Frequency [Hz] LIM EN 55022 F QP MES STD_SUB1 Field Strength QP Limit

9 Conduction CPCEMC EMI TEST Conducted Disturbance EUT: Manufacturer: Operating Condition: Test Site: Operator: Test Specification: Comment: SAC 10m xbrong AC:230V/50Hz M/N: HGP-CH08 L SCAN TABLE: "EN 55022 Voltage fin" Short Description: EN 55022 Voltage Start Stop Step Detector Meas. IF Transducer Frequency Frequency Width Time Bandw. 150.0 khz 30.0 MHz 0.4 % QuasiPeak 1.0 s 9 khz None Average Level [db 礦 ] 80 70 x x x x 60 x x 50 40 + 30 + 20 + + 10 + + 0 150k 300k 500k 1M 2M 3M 5M 7M 10M 30M Frequency [Hz] x MES 70186V4_fin QP + MES 70186V4_fin AV MES 70186V4_pre PK MES 70186V4_pre AV LIM EN 55022 V QP LIM EN 55022 V AV Voltage QP Limit Voltage AV Limit

CPCEMC EMI TEST Conducted Disturbance EUT: Manufacturer: Operating Condition: Test Site: Operator: Test Specification: Comment: SAC 10m xbrong AC:230V/50Hz M/N: HGP-CH08 N SCAN TABLE: "EN 55022 Voltage fin" Short Description: EN 55022 Voltage Start Stop Step Detector Meas. IF Transducer Frequency Frequency Width Time Bandw. 150.0 khz 30.0 MHz 0.4 % QuasiPeak 1.0 s 9 khz None Average 80 Level [db 礦 ] 70 60 x x x x x x 50 40 30 + + + + + + 20 10 0 150k 300k 500k 1M 2M 3M 5M 7M 10M 30M Frequency [Hz] x MES 70186V3_fin QP + MES 70186V3_fin AV MES 70186V3_pre PK MES 70186V3_pre AV LIM EN 55022 V QP LIM EN 55022 V AV MES STD_SUB2 Voltage QP Limit Voltage AV Limit