Electrical Specifications

Similar documents
Electrical Specifications

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

150 Watt Industrial (WLT)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

LFWLP W 12V 15.00A 25.00A 92%

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

General. Environmental. EMC & Safety

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

C B. Models. Models 2MOPP

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Model and Output Power Output Nominal Voltage Package Option Means of Protection Grade. 12 V DC: -US12 Open Frame: -OF. 24 V DC: -US24 U-Chassis: -UC

PDAM500 Series 500W Power Supply

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

Watts HCP Series

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

LB115S 115W Single Output

IP67 DESCRIPTION KEY FEATURES MARKET SEGMENT AND APPLICATIONS TRC ELECTRONICS, INC

Output Voltage (Vfan) & Current

DDP400 SERIES KEY FEATURES DESCRIPTION MARKET SEGMENTS AND APPLICATIONS

POWER. CPS250-M Series. 250 Watt AC-DC Power Supplies. Data Sheet. Total Power: 250 Watts Input Voltage: V # of Outputs: Single

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Output Voltage (Vfan) Convection-cooled (6,7) Forced-cooled (8) & Current

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

MB120S 120W Single Output Medical Series

Electrical Specifications

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

VOF XX - XXX - X

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

POWER. CPS250-M Series. 250 Watt AC-DC Power Supplies. Data Sheet. Total Power: 250 Watts Input Voltage: V # of Outputs: Single

DDP400 and MDP400, SC series, are sealed, full potted, compact, high efficiency, small form factor AC-DC power supplies.

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

TB65 65W Single Output Test and Measurement/Industrial Series

General. Environmental. EMC & Safety

Electrical Specifications

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

VP ELECTRONIQUE MASSY - Tel:

MTC Series 15 W AC/DC Switching Power Supply Module Medical

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Electrical Specifications

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet

AC-DC ITE & Medical Switching Power Supply

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

1000W Single Output Medical Type. MSP-1000 series. File Name:MSP-1000-SPEC

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

3 in 1 Dimmable (0-10Vdc, PWM signal, or resistance)

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

DDP400 and MDP400, SC series, are sealed, full potted, compact, high efficiency, small form factor AC-DC power supplies.

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Metal Case Power Supplies

HEC-45LTN-45PFAS Rev A

AC-DC ITE & Medical Switching Power Supply

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

HRPG-1000 series. 1000W Single Output with PFC Function. File Name:HRPG-1000-SPEC Sicherheit ID

TE60 60W Single Output External Power Test & Measurement/Industrial Series

CCH400 & CCH600 Series

For more information, please visit the product page. output. output current max (A)

COMPACT MEDICAL GRADE 365 W AC-DC POWER SUPPLY MFA350 SERIES

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

Output Full Load

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

Transcription:

450 Watt Medical Features 4 x 6.5 x 1.61 inches Approval to EN60601 3rd Edition Dual Fusing Current Sharing Option Cover and Fan Options Peak Power Capability Class B EMI & Medical (BF) Safety Approvals Meets standard IEC60601-1-2 : 2014 (4th Edition) 79 Electrical Specifications Input Voltage 90-264 VAC/120-390 VDC, Universal Input Frequency 47-63 Hz Input Current 120 VAC: 4.5 A max. 230 VAC: 2.3 A max. Input Protection Dual Fusing, T8A/250 V in Live & Neutral No Load Power 120 VAC: 0.4 230 VAC: 0.8 Inrush Current 120 VAC: 40 A max. 230 VAC: 75 A max. Leakage Current Earth Leakage Current - 270 µa, Touch Leakage Current - 45 µa @ 120 VAC / 63 Hz Efficiency 120 VAC: 88% (24 V, 48 V, 30 V) 86% (12 V) 83% (5 V) Typical 230 VAC: 90% (24 V, 48 V, 30 V) Hold-up Time 120 VAC: 10 ms 230 VAC: 10 ms Power Factor 120 VAC: 0.98 230 VAC: 0.95 Output Power 155 to 450 W (475 W for 24 V, 30 V & 500 W for 48 V model only for 5 seconds max.) Line Regulation +/-0.5% Load Regulation +/-3% Transient Response < 10%, 50% to 100% load change, 50 Hz, 50% duty cycle, 0.1 A/µs, recovery time < 5 ms Rise Time < 100 ms Set Point Tolerance +/-1% Output Adjustability +/-3% Over Current Protection 120 to 150%, Hic-Up Type Over Voltage Protection 114%, Latch Type Short Circuit Protection Short term, autorecovery Over Temperature Protection 130 C primary heat sink, autorecovery Current Share Upto 2 Supplies connected in parallel (optional) Switching Frequency PFC converter:variable, 45-160 khz typical Resonant converter:variable, 35-250 khz;90 khz typical Operating Temperature -0 to +70 C, refer derating curve Storage Temperature -40 to +85 C Relative Humidity 95% Rh, noncondensing Altitude Operating: 10,000 ft.; Nonoperating: 40,000 ft. MTBF 1.28m Hours, Telcordia -SR332-issue 3 Isolation Voltage 2MOPP 5940 VDC between input to output,1mopp 2121 VDC input to Earth (Ref. Note: 9) Cooling Convection: 300 W; 420 LFM: 450 W (24 V, 30 V & 48 V model) Convection: 250 W; 420 LFM: 450 W (12 V & 15 V model) Convection: 155 W; 420 LFM: 275 W (5 V model)

Model Number Type Voltage Max. Load Max. Load Min. Load Ripple 1 (Convection) (420 LFM) LFMWLT450-1000 U-Channel 5 V 31.0 A 55.0 A 0.0 A 2% LFMWLT450-1000-I U-Channel + OR-ing MOSFET 5 V 31.0 A 55.0 A 0.0 A 2% LFMWLT450-1000-T Top Fan 5 V 31.0 A 55.0 A 0.0 A 2% LFMWLT450-1000-I-T Top Fan + OR-ing MOSFET 5 V 31.0 A 55.0 A 0.0 A 2% LFMWLT450-1000-S Side Fan 5 V 31.0 A 55.0 A 0.0 A 2% LFMWLT450-1000-I-S Side Fan + OR-ing MOSFET 5 V 31.0 A 55.0 A 0.0 A 2% LFMWLT450-1001 U-Channel 12 V 20.83 A 37.5 A 0.0 A 2% LFMWLT450-1001-I U-Channel + OR-ing MOSFET 12 V 20.83 A 37.5 A 0.0 A 2% LFMWLT450-1001-T Top Fan 12 V 20.83 A 37.5 A 0.0 A 2% LFMWLT450-1001-I-T Top Fan + OR-ing MOSFET 12 V 20.83 A 37.5 A 0.0 A 2% LFMWLT450-1001-S Side Fan 12 V 20.83 A 37.5 A 0.0 A 2% LFMWLT450-1001-I-S Side Fan + OR-ing MOSFET 12 V 20.83 A 37.5 A 0.0 A 2% LFMWLT450-1002 U-Channel 15 V 16.66 A 30.0 A 0.0 A 2% LFMWLT450-1002-I U-Channel + OR-ing MOSFET 15 V 16.66 A 30.0 A 0.0 A 2% LFMWLT450-1002-T Top Fan 15 V 16.66 A 30.0 A 0.0 A 2% LFMWLT450-1002-I-T Top Fan + OR-ing MOSFET 15 V 16.66 A 30.0 A 0.0 A 2% LFMWLT450-1002-S Side Fan 15 V 16.66 A 30.0 A 0.0 A 2% LFMWLT450-1002-I-S Side Fan + OR-ing MOSFET 15 V 16.66 A 30.0 A 0.0 A 2% LFMWLT450-1003 U-Channel 24 V 12.3 A 18.75 A 0.0 A 2% LFMWLT450-1003-I U-Channel + OR-ing MOSFET 24 V 12.3 A 18.75 A 0.0 A 2% LFMWLT450-1003-T Top Fan 24 V 12.3 A 18.75 A 0.0 A 2% LFMWLT450-1003-I-T Top Fan + OR-ing MOSFET 24 V 12.3 A 18.75 A 0.0 A 2% LFMWLT450-1003-S Side Fan 24 V 12.3 A 18.75 A 0.0 A 2% LFMWLT450-1003-I-S Side Fan + OR-ing MOSFET 24 V 12.3 A 18.75 A 0.0 A 2% LFMWLT450-1004 U-Channel 48 V 6.25 A 9.37 A 0.0 A 2% LFMWLT450-1004-I U-Channel + OR-ing MOSFET 48 V 6.25 A 9.37 A 0.0 A 2% LFMWLT450-1004-T Top Fan 48 V 6.25 A 9.37 A 0.0 A 2% LFMWLT450-1004-I-T Top Fan + OR-ing MOSFET 48 V 6.25 A 9.37 A 0.0 A 2% LFMWLT450-1004-S Side Fan 48 V 6.25 A 9.37 A 0.0 A 2% LFMWLT450-1004-I-S Side Fan + OR-ing MOSFET 48 V 6.25 A 9.37 A 0.0 A 2% LFMWLT450-1005 U-Channel 30 V 10.0 A 15.0 A 0.0 A 2% LFMWLT450-1005-I U-Channel + OR-ing MOSFET 30 V 10.0 A 15.0 A 0.0 A 2% LFMWLT450-1005-T Top Fan 30 V 10.0 A 15.0 A 0.0 A 2% LFMWLT450-1005-I-T Top Fan + OR-ing MOSFET 30 V 10.0 A 15.0 A 0.0 A 2% LFMWLT450-1005-S Side Fan 30 V 10.0 A 15.0 A 0.0 A 2% LFMWLT450-1005-I-S Side Fan + OR-ing MOSFET 30 V 10.0 A 15.0 A 0.0 A 2% 2 Innovations in Power

Connectors J1 Pin 1 AC LINE Pin 3 AC NEUTRAL Pin 5 EARTH Spade Connector (J5) J2 Pin 1 V1 Pin 2 RTN J3 Pin 1 NC Pin 2 PF OK Pin 3 POWER GOOD Pin 4 DC RETURN Pin 5 +5 VSTBY Pin 6 +VE REMOTE SENSE Pin 7 -VE REMOTE SENSE Pin 8 CS Pin 9 DC RETURN Pin 10 REMOTE ON/OFF J4 (FAN OUTPUT) Pin 1 + VE Pin 2 - VE Notes 1. Ripple is peak to peak with 20 MHz bandwidth and 10 µf (Tantalum capacitor) in parallel with a 0.1 µf capacitor at rated line voltage and load ranges. Please contact factory/ sales representative for minimum load required for ripple to be within specification. 2. Combined output power of main output, fan supply and standby supply shall not exceed max. power rating. 3. Standby output voltage 5 V/ 1.5A(convection) / 2A(420LFM) with tolerance including set point accuracy, line and load regulation is +/-10%. Ripple and noise is less than 5%. 4. Fan supply output voltage 12V/ 500mA with tolerance including set point accuracy, line and load regulation is +/-30% and needs min. 1% load on main output to be within regulation band. Ripple and noise is less than 10%. 5. Specifications are for nominal input voltage, 25 C unless otherwise stated. 6. PSU is supplied with J3, pin-9 and pin-10 shorted to enable main output without remote on/off feature. 7. Derate output power linearly to 80% from 90 VAC to 80 VAC input. 8. For ordering current sharing with OR-ing option add I suffix with the model number. 9. Output to GND- 1500VAC for type BF. 10. The J5(Earth) spade connector can be used for U-Channel option products only. When fan options are required the earth connection provided in the input AC connector should be used (Pin 5 J1) 81

Mechanical Specifications AC Input Connector (J1) Tyco: 1-1123724-3 Mating: 1-1123722-5 EARTH (J5) Molex: 19705-4301 Mating: 190030001 DC Output Connector (J2) 6-32 inches Screw Pan HD Mating: Designed to accept Ring Tongue Terminal AMP : 8-31886-1, wherein one 16 AWG(max) wire can be crimped. Note : One Ring Tongue Terminal with 16 AWG is recommended for current upto 11A only. Use multiple tongue terminals with wire for more current. Signal Connector (J3) Molex: 22-23-2101 Mating: 22-01-2107; Pins: 08-50-0113 Dimensions 4.0 x 6.5 x 1.61 inches (101.6 x 165.1 x 41.0 mm) Weight 900 gm EMC Parameter Conducted Emissions Radiated Emissions Input Current Harmonics Voltage Fluctuation and Flicker ESD Immunity Radiated Field Immunity Electrical Fast Transient Immunity Surge Immunity Conducted Immunity Magnetic Field Immunity Voltage dips, interruptions Conditions/Description EN 55011-B,CISPR22-B, FCC PART15-B EN 55011 B EN 61000-3-2 EN 61000-3-3 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 EN 61000-4-11 Safety Criteria Pass Pass Class D Pass Level 4, Criterion A Level 3, Criterion A Level 3, Criterion A Level 3, Criterion A Level 3, Criterion A Level 4, Criterion A Criterion A & B CE Mark Complies with LVD Directive Approval Agency Nemko, UL, C-UL Safety Standard(s) EN60601-1, IEC 60601-1 (ed.3), ANSI / AAMI ES 60601-1, CSA C22.2 No. 60601-1 Safety File Number(s) NEMKO: P14218171, NO79068 UL: E173812 Signal(s) Power Good Signal Remote Sense Remote on/off TTL signal goes high after main output is within regulation band, delay is 0.1 to 0.3 s Compensates for 200 mv drop To turn on PSU short remote pin to ground 4 Innovations in Power

Derating Curve (From 90 V to 264 V AC I/P) Convection load: 155W up to 40 C De-rate above 40 C @ 1.67% per C Forced air cooled load : 275W up to 40 C De-rate above 40 C @ 1.67% per C Convection load: 250W up to 40 C De-rate above 40 C @ 1.67% per C Forced air cooled load : 450W up to 40 C De-rate above 40 C @ 1.67% per C Convection load: 300W up to 50 C De-rate above 50 C @ 2.5% per C Forced air cooled load : 450W up to 50 C De-rate above 50 C @ 2.5% per C 83

Mechanical Drawing 6 Innovations in Power

Mechanical Drawing 85

Mechanical Drawing 8 Innovations in Power

Installtion instruction for current sharing: During the installation and setup of parallel supplies in a system it is important that a single remote sense point be used for all the supplies. The remote sense voltage between the supplies must be adjusted to within 2% to ensure the supplies are inside the 3% capture window. If the supplies are not initially adjusted inside the capture window the supplies will not current share. Note: CURRENT SHARING facility is inclusive with the unit only with ordering of the CURRENT SHARING option unit i.e. LFWLT450-1XXX-I or LF(M)WLT450-1XXX-I. Set-Up Procedures: 1. Connect load cables to the outputs of each supply. 2. Connect the remote sense lines to the load in twisted style. (A common remote sense point must be used for all the supplies in parallel). 3. Connect all the current share pins on the J3 connector between the supplies. 4. Adjust remote sense voltage of each supply to within 1% of rated output voltage or readjust to required set point. (Adjustment to be done with all other parallel supplies off). 5. Current sharing between the supplies can be verified by monitoring the output current of each supply with a hall effect DC current probe. The supplies should share to within 10% of the total load current. 6. The current share circuit has a capture window voltage of +/- 3% of the rated output voltage. If the output remote sense voltage of one of the supplies is adjusted outside the 3% window the supplies will not current share. 87