WIRING Model FC Mass Flow Computer Diagrams
Model FC Mass Flow Computer Diagrams CONTENTS INTRODUCTION I. ForceMeter TM with Internal Power... 3 II. ForceMeter TM with External Power... 4 III. Niagara Meters 050 with Internal Power Pulse Output... 5 IV. Niagara Meters 050 with Internal Power Current Output... 6 V. Niagara Meters 050 with External Power Pulse Output... 7 VI. Niagara Meters 050 with External Power Current Output... 8 VII. Niagara Meters Magmeter 6600 with Internal Power Active Frequency/Pulse... 9 VIII. Niagara Meters Magmeter 6600 with Internal Power Current Output... 0 IX. Niagara Meters Magmeter 6600 with External Power Passive Frequency/Pulse...
FC Flow Computer Diagrams INTRODUCTION This guide illustrates the proper wiring connections required for the Model FC Mass Flow Computer to be connected with other Niagara Meters products. These diagrams should be consulted during installation and for any maintenance. Please consult the associated Installation and Operation Manual (IOM) for additional details and instructions. Niagara Meters Customer Support can be reached at (800) 778-95 for additional inquires.
FC Flow Computer Diagrams I. ForceMeter TM with Internal Power Conduit Entry for Customer Conduit Entry for Customer Customer 4-0mA Output 4 V Transmitter Enclosure Pre-wired to Transmitter Customer Customer Belden 848 or Equivalent Meter Enclosure Pre-wired to Meter Sensing Element 4 V 3
FC Flow Computer Diagrams II. ForceMeter TM with External Power Conduit Entry for Customer Conduit Entry for Customer Power Supply -36 VDC Customer 4-0mA Output Transmitter Enclosure Pre-wired to Transmitter Customer Customer Belden 848 or Equivalent Meter Enclosure Power Supply 8-36 VDC Pre-wired to Meter Sensing Element 4
FC Flow Computer Diagrams III. Niagara Meters 050 with Internal Power Pulse Output SW OP CAL TP5 R CAL C SW R RP RP3 RP +VIN P OUT Gnd + Voltage In 0 000 Hz 4 0mA ZERO CAL TP3 CUTOFF TP GND 4 Model 050 (A) + E (B) + S (C) S (D) E RTD 3 4 GRN WHT RED BLK + E + S S E + VIN POUT GND + VDC 75 of 8 gauge wire Bottom Top 4 5
FC Flow Computer Diagrams IV. Niagara Meters 050 with Internal Power Current Output SW OP CAL TP5 R CAL C SW R RP RP3 RP +VIN P OUT Gnd + Voltage In 0 000 Hz 4 0mA ZERO CAL TP3 CUTOFF TP GND 4 Model 050 (A) + E (B) + S (C) S (D) E RTD 3 4 GRN WHT RED BLK + E + S S E + VIN POUT GND + VDC 75 of 8 gauge wire Bottom Top 4 BC Terminals 6
FC Flow Computer Diagrams V. Niagara Meters 050 with External Power Pulse Output SW OP CAL TP5 R CAL C SW R RP RP3 RP +VIN P OUT Gnd + Voltage In 0 000 Hz 4 0mA Power Supply -36 VDC ZERO CAL TP3 CUTOFF TP GND Model 050 (A) + E (B) + S (C) S (D) E RTD 3 4 GRN WHT RED BLK + E + S S E + VIN POUT GND + VDC Power Supply -36 VDC 75 of 8 gauge wire Bottom Top 7
FC Flow Computer Diagrams VI. Niagara Meters 050 with External Power Current Output SW OP CAL TP5 R CAL C SW R RP RP3 RP +VIN P OUT Gnd + Voltage In 0 000 Hz 4 0mA Power Supply -36 VDC ZERO CAL TP3 CUTOFF TP GND MARK V (A) + E (B) + S (C) S (D) E RTD 3 4 GRN WHT RED BLK Model 050 + E + S S E + VIN POUT GND + VDC Power Supply -36 VDC 75 of 8 gauge wire Bottom Top 8
FC Flow Computer Diagrams VII. Niagara Meters 6600 with Internal Power Active Frequency/Pulse Spare Active Frequency Pulse J J J J RDN3 J J 500 Ω T A, 50V RDN RDN 3 L N 4 5 6 NC C NO 7 8 9 0 3 4 5 NC C NO F/P F/P O/C O/C I I 4 Spare Active Frequency Pulse J J J J RDN3 J J 500 Ω T A, 50V RDN RDN 3 L N 4 5 6 NC C NO 7 8 9 0 3 4 5 NC C NO F/P F/P O/C O/C I I 4 9
FC Flow Computer Diagrams VIII. Niagara Meters 6600 with Internal Power Current Output Spare RDN3 J J T A, 50V RDN RDN 3 L N 4 5 6 NC C NO 7 8 9 0 3 4 5 NC C NO F/P F/P O/C O/C I I Spare RDN3 J J T A, 50V RDN RDN 3 L N 4 5 6 NC C NO 7 8 9 0 3 4 5 NC C NO F/P F/P O/C O/C I I 0
FC Flow Computer Diagrams IX. Niagara Meters 6600 with Internal Power Passive Frequency/Pulse
50 Venture Boulevard Spartanburg, SC 9306 Tel: 800.778.95 Fax: 864.574.8063 E-mail: sales@niagarameters.com www.niagarameters.com 0 All rights reserved. All data subject to change without notice. M90 Rev. B