The outputs can also be programmed as 0-5 Vdc, 0-10 Vdc, 0-20 ma, 4-20 ma, Frequency, RPM, PWM or digital on/off signals.

Similar documents
TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

TECHNICAL DATASHEET #TDAX Universal Signal Inputs CAN Controller V, ma, Digital, PWM, Hz/RPM, Counter Inputs CANopen P/N: AX030121

P/N: AX Applications: Off-highway construction equipment Municipal vehicles. Ordering Part Numbers:

Programmable with Electronic Assistant Simulink

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER

P/N: AX Applications: Typical applications can include: test stands; and industrial automation.

TECHNICAL DATASHEET #TDAX021901

TECHNICAL DATASHEET #TDAX CAN SAE J1939, Dual Output Valve Controller

Ordering Part Numbers: SAE J1939 version Controller: AX022400

TECHNICAL DATASHEET #TDAX ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER

Applications: oil and gas equipment automation; off-highway machine automation; agricultural equipment

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)

P/N: AX Ordering Part Numbers: SAE J1939 Controller: For baud rate, refer to the table below for the appropriate P/N. Mating Plug Kit: AX070123

PRELIMINARY. Preliminary TECHNICAL DATASHEET #TDAX DC MOTOR CONTROLLER P/N: AX100650

TECHNICAL DATASHEET #TDAX INPUT, 12 OUTPUT VALVE CONTROLLER,

TECHNICAL DATASHEET #TDAX032100

TECHNICAL DATASHEET #TDAX022420

Applications: Power generation, Cogeneration, Stationary power Large engines

Applications: Off-highway construction equipment Municipal vehicles Material handling equipment (forklifts, etc.) Ordering Part Numbers:

TECHNICAL DATASHEET #TDAX INPUTS, 2 BIDIRECTIONAL

with Electronic Assistant

TECHNICAL DATASHEET #TDAX QUAD VALVE CONTROLLER P/N: AX SERIES

with Electronic Assistant

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

P/N: AX06080X. TECHNICAL DATASHEET #TDAX06080X Triaxial Inclinometer SAE J1939 or CANopen 2 M12 Connector(s), IP67 with Electronic Assistant

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Model 140 Inline Amplifier

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

Penny & Giles No-Contact, Rotary Position Sensor NRH271 & NRH272

TECHNICAL PRODUCT DATASHEET

TITANIUM SERIES R 51 PART NUMBER SELECTION. High Performance Multiport Switches. Our Most Important Connection is with You.

Hexa Multi Module 366HMM. Introduction. Design Specifications. Key Features

Solid State Pressure Sensors D8M

Low Profile. 3 Year Warranty

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

General. Environmental. EMC & Safety

MAE3. Absolute Magnetic Kit Encoder Page 1 of 8. Description. Mechanical Drawing. Features

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

Rotary Position Technology Incremental Encoders

PAGE 1/12 ISSUE SERIES DP3T/SPDT PART NUMBER R595 XXX XXX

DP2000 ORDERING GUIDE To Order MODEL NO.

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

BH series Paddle joystick controllers

Rotary Measurement Technology Incremental Encoders

J1 Line APPLICATION FEATURES DESCRIPTION RUGGED-DUTY SHAFTED ENCODERS

Connection to the sensor is with simple flying leads for customer termination. 1 Page NRH300DP Rev B 09/15

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

Wimesure 54, rue de Versailles CHEVREUSE Tél Fax

ULTRAVOLT HIGH-POWER C SERIES HIGH VOLTAGE CAP-CHARGING SUPPLY

2520 Pulsed Laser Diode Test System

Model 3102D 0-2 kv H.V. Power Supply

PSI Temperature Scanners

AC/DC Power Supply Series APPLICATION NOTE

HX-EP SERIES DIGITAL OUTPUT

Signal Conditioning Amplifier

No-Contact, CANbus Rotary Position Sensor NRH27C

BL series Miniature paddle joystick controllers

PRODUCT SPECIFICATION

DVC700 Series Programmable System Controller

Portable Multi-Channel Recorder Model DAS240-BAT

AC/DC Power Supply Series APPLICATION NOTE

poly-planar ME-51 Subwoofer Amplifier Waterproof Marine Audio

ULTRAVOLT HIGH-POWER C SERIES

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

Lexium integrated drives

HD - Incremental Encoders

100W Wide Band Power Amplifier 6GHz~18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz Gain db

PLC-K506 Series FEATURES DESCRIPTION FEATURES

Dual Reversing Module

AC/DC Power Supply Series APPLICATION NOTE

4-20 ma Vibration Transmitter, Top connector

Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial Power Supply

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

American Power Design, Inc.

AC AC AC

RS3400W/04 77 GHz Radar Sensor

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

Agilent N3300 Series DC Electronic Loads

DVC700 Series Programmable System Controller

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Sealed Interface Control: EC20300

AC/DC Power Supply Series APPLICATION NOTE

maxon document number:

Multiple Instrument Station Module

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

PV 102. IECEx. Piezoelectric velocity sensor FEATURES. From the Vibro-Meter product line

Ultra Low-Noise Variable Gain Low-Frequency Voltage Amplifier

LoopBack Relay. LB363 Series. With Built-in AC Bypass Capacitors. LoopBack Relay, Sensitive Coil, thru-hole with AC Bypass Capacitors

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

LoopBack Relay. GLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

MA3. Miniature Absolute Magnetic Shaft Encoder Page 1 of 8. Description. Mechanical Drawing. Features

ACT111A. 4.8V to 30V Input, 1.5A LED Driver with Dimming Control GENERAL DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION CIRCUIT

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

HP 34401A Specifications 8

Analog amplifier RA. RE Edition: Replaces:

FEATURES AND BENEFITS. Compact size: 6.5 x 2.8 x 1.5

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

ID/HX-EP SERIES DIGITAL OUTPUT

Transcription:

TECHNICAL DATASHEET #TDAX130521 ECONOMY DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER 2 Analog, Resistive, Digital, Frequency (RPM) or PWM Signal Inputs 2 Analog, Digital, Frequency or PWM Signal Outputs +5V reference (50 ma) Isolated CANopen Developed with Simulink with Electronic Assistant Description: The dual channel universal signal converter accepts two voltage, current, resistive, frequency, RPM, PWM or digital control signal inputs and converts them into two signal outputs (analog voltage, analog current or digital signal). The control can be networked to a CANopen networked control system. The unit has isolation between power and CAN. Using the Electronic Assistant programming tool, the user can select the desired inputs from the following signal options. 0-5 V, 0-10 Vdc 4-20 ma, 0-20 ma or 0-200 ma 20 Ohms to 250 kohm Frequency/RPM PWM or Digital (Active High or Active Low) A +5V, 50 ma reference is available to power a sensor input. P/N: AX130521 The outputs can also be programmed as 0-5 Vdc, 0-10 Vdc, 0-20 ma, 4-20 ma, Frequency, RPM, PWM or digital on/off signals. A rugged power supply interface accepts 12 Vdc or 24 Vdc nominal for battery powered machine applications. The unit carries an IP67 rating. The rugged enclosure with a 12 pin TE Deutsch connector is suitable for harsh environments. It operates from -40 to 85 C (-40 to 185 F). Applications: power gen set engine control systems oil and gas equipment automation off-highway machine automation Ordering Part Numbers: Dual Channel Universal Signal Converter, CANopen : AX130521 Accessories: Mating Plug Kit: PL-DTM06-12SA EDS File, UMAX130521: Downloadable from www.axiomatic.com. Go to the Log-In page. Request the password from sales@axiomatic.com.

Block Diagram The controller belongs to a family of Axiomatic smart controllers with programmable internal architecture. This provides users with flexibility, allowing them to build their own custom controller with a required functionality. Technical Specifications: Specifications are indicative and subject to change. Actual performance will vary depending on the application and operating conditions. Users should satisfy themselves that the product is suitable for use in the intended application. All our products carry a limited warranty against defects in material and workmanship. Please refer to our Warranty, Application Approvals/Limitations and Return Materials Process as described on www.axiomatic.com/service.html. Power Supply Power Supply Input 12 Vdc or 24 Vdc nominal 9 36 Vdc power supply range Shutdown voltage is 8.0 Vdc. Reverse polarity protection Overvoltage protection is up to 45 V. TDAX130521 2

Inputs Inputs 2 Universal Signal Inputs User programmable as Voltage, Current, Resistive, Frequency, RPM, PWM or Digital signal inputs types. Refer to Table 1.0. Table 1.0 User Programmable Universal Inputs Analog & Digital Input Functions Voltage Input, Current Input, Resistive Input or Digital Input 12 bit Analog to Digital Voltage Input 0-5 V (Impedance 110 kω) 0-10 V (Impedance 130 kω)) Current Input 0-200 ma (Impedance 5 Ω); 1V max. 0-20 ma (Impedance 249 Ω) 4-20 ma (Impedance 249 Ω) Resistive 20 Ohms to 250 kohms Self-calibrating Digital Input Level Accepts 5 V TTL Accepts up to Vps Threshold: Low <1 V High >2.2 V Normal, Inverse or Latched 10kΩ Pull up/pull down Digital Input Active High or Active Low with 10 kohm pull-up or pull-down Timer Input Functions PWM Input, Frequency Input, RPM Input 15-bit Timer PWM Input 100 Hz to 10 khz 0 to 100% D.C. (Impedance 1 MΩ) Frequency/RPM Input 0.5 Hz to 50 Hz; 10 Hz to 1 khz; or 100 Hz to 10 khz 1 to 99% D.C. Maximum and Minimum Ratings Characteristic Min Max Units Power Supply 9 36 V dc Voltage Input 0 36 V dc Current Input 0(4)-20 ma 0 12 Vdc Current Input 0-200 ma 0 1V Vdc Resistive Input 20 250 000 Ω Digital Input 0 36 Vdc PWM Duty Cycle 0 100 % PWM Frequency 100 10 000 Hz PWM Voltage pk - pk 0 36 V dc RPM Frequency 0.5 10 000 Hz Input Grounds 1 provided All inputs are protected against short to GND. All inputs, except current inputs, are protected against shorts to Nominal Vps (36Vdc). Input Accuracy and Resolution Input Type Input Range Accuracy Resolution Voltage 0-5V +/-1% 1 mv 0-10V +/-1% 1 mv Current 0(4)-20mA +/-2% 1 µa 0-200mA +/-2% 1 µa Resistive 20-250kΩ +/-1% 1 Ω for lower ranges 1 kω for higher ranges Frequency 0.5Hz-50Hz +/-1% 0.01 Hz 10Hz-1kHz +/-1% 0.1 Hz 100Hz-10kHz +/-1% 1 Hz PWM Low Frequency +/-1% 0.01% High Frequency +/-1% 0.01% TDAX130521 3

Outputs Outputs Output Accuracy and Resolution Voltage Reference for Output Terminals General Specifications Microprocessor Isolation Typical Quiescent Current Response Time Control Logic Simulink Communications Network Termination User Interface Operating Conditions Storage Temperature Vibration Shock Weight Enclosure 2 Signal Outputs Voltage, Current or Digital The outputs are user selectable as follows. Refer to Table 2.0. Table 2.0: Programmable Outputs Analog Voltage or Voltage Output: Current Outputs: 0-5 Vdc or 0-10 Vdc Current Output: 0-20 ma or 4-20 ma Maximum load resistance is < 500 Ohms. PWM, Frequency or Mixed PWM/Frequency Output: Digital Output: Compliance Voltage is 10V. 0.1 Hz to 50 khz 0-100% D.C. 5 V or 12 V Amplitude Push pull output Over-current protection (50 ma) Digital Level Digital ON/OFF 5 V or 12 V Amplitude Output Type Output Range Output Accuracy Output Resolution Voltage 0-5V +/- 1% 1 mv 0-10V +/- 1% 1 mv Current 0(4)-20mA +/- 1% 0.5 µa Digital On/Off +/- 1% N/A Frequency 0.1Hz-50kHz +/- 1% TBD PWM Low Frequency +/- 1% TBD High Frequency +/- 1% TBD +5V, 50 ma, Ground is shared with Input Grounds. Fully protected against short circuit to output ground. Unit will fail safe in the case of a short circuit condition, self-recovering when the short is removed. STM32F205VGT 300 Vrms Power and CAN are isolated from each other. 60 ma @ 12Vdc typical; 34 ma @ 24Vdc typical 28.4 milliseconds Standard embedded software is provided. (Application-specific control logic or a set point file is available on request.) Model AX130521 was developed using Simulink. Simulink is a model-based design tool from Mathworks. 1 Isolated CAN port (CANopen ) It is necessary to terminate the network with external termination resistors. The resistors are 120 Ohm, 0.25W minimum, metal film or similar type. They should be placed between CAN_H and CAN_L terminals at both ends of the network. EDS File provided to interface to standard CANopen tools -40 to 85 C (-40 to 185 F) -55 to 125 C (-67 to 257 F) IP67 MIL-STD-202G, Test 204D and 214A (Sine and Random) 10 g peak (Sine) 7.86 Grms peak (Random) MIL-STD-202G, Test 213B 50g 0.55 lb. (0.249 kg) High Temperature Nylon housing - Deutsch IPD PCB Enclosure (EEC-325X4B) 4.62 x 5.24 x 1.43 inches 117.42 x 133.09 x 36.36 mm (W x L x H excluding mating plugs) Refer to the dimensional drawing. TDAX130521 4

Installation Dimensional Drawing For mounting information, refer to the dimensional drawing. Mounting holes sized for ¼ inch or M6 bolts. The bolt length will be determined by the end-user s mounting plate thickness. The mounting flange of the controller is 0.63 inches (16 mm) thick. If the module is mounted without an enclosure, it should be mounted vertically with connectors facing left and right to reduce likelihood of moisture entry. The CAN wiring is considered intrinsically safe. The power wires are not considered intrinsically safe and so in hazardous locations, they need to be located in conduit or conduit trays at all times. The module must be mounted in an enclosure in hazardous locations for this purpose. No wire or cable harness should exceed 30 meters in length. The power input wiring should be limited to 10 meters. All field wiring should be suitable for the operating temperature range. Install the unit with appropriate space available for servicing and for adequate wire harness access (6 inches or 15 cm) and strain relief (12 inches or 30 cm). Electrical Connections Deutsch DTM series 12 pin receptacle (P/N: DTM13-12PA-R008) 20 AWG wire is recommended for use with contacts 0462-201-20141. Mating plug KIT: Available from Axiomatic as p/n: PL-DTM06-12SA. It is comprised of the following Deutsch IPD parts: plug (DTM06-12SA); wedgelock (WM12S); and 12 contacts (0462-201-20141) as well as 6 sealing plugs (0413-204- 2005). Pin # Description 1 Analog/Digital Input 1 2 Input GND 3 Analog/Digital Input 2 4 CAN_H 5 CAN_L 6 Power + 7 Power - 8 +5V Reference 9 Analog/Digital Output 2+ 10 Output GND 2 11 Output GND 1 12 Analog/Digital Output 1+ CANopen is a registered community trade mark of CAN in Automation e.v. Simulink is a registered trademark of The Mathworks, Inc. Form: TDAX130521-11/24/17 TDAX130521 5