Fire proof sliding doors REI leaf, 2 leaves
|
|
- Annice Randall
- 6 years ago
- Views:
Transcription
1 Portoni scorrevoli REI 120: Istruzioni di montaggio Fire proof sliding doors REI leaf, 2 leaves Mounting Instructions General Information Maintenance SEPTEMBER 2011 NOVOFERM SCHIEVANO s.r.l Camposampiero Padova (Italy) Via A. Volta, 1 Ph Fax export@novoferm.it 1
2 Fire proof sliding doors REI 120: mounting instructions a) Check if order sizes are the same of the wall size. In case of more sliding doors, distribute the materials following the code indicated on each component. b) Check verticality and square of structural wall, verify if the floor is plane in correspondence of the wall and the side of rest panel in opening position. c) Fix the closing jamb (1) [ref. (27) in case of sliding with back counterbalance] with expansion dowels, position it to 2 cm from the hole. We suggest to fix also a dowel in the floor. Bind the spin of same mounting in collision case. [In case of sliding door 2 leaves, position the guide and make the references, written on the guide, equal to the wall opening and use the counterbalance covering (26) in order to determine the height from the floor.] d) Fix the superior guide (2) by dowels (not in the equipment) laying it down on the jamb (1). In case of door closing by thermofuse, the guide must be horizontal. In case of door closing by electromagnet, fix the guide in the opposite side of the closing point 2-3 cm up. e) Assemble the door panels (3) on horizontal floor (pay attention not to spoil them) and stop them to the C shape profiles, bottom and top (4) by means of supplied screws (5). Mount the thermal gasket (23) as per scheme. f) Fix the top horizontal labyrinth (6) on the door. g) Mount the wheels (7) on the supports joined to the C top profile (4). h) Turn until the panel arise the vertical position, attach the wheels to the guide (2), already fixed. i) Regulate the height of the door to assure an height of slide from floor of 1 cm (+/ 5 mm) during movement. j) Slide the door panel over the wall light until the position of the wheel of the bottom guide appears (8). Fix the wheel with the expansion dowel equipped. Verify that it maintains the panel in vertical position. k) Position the stirrup door wheel of the counterbalance (9) with the plate in equipment (10) by the bolts (11). l) Apply the stirrup of the thermofuse (12) if any, use the plate (10) and the bolts (11). In case of mq. > 10, fix the guide with one more point of welding, and then with cold galvanizing. m) In case of thermofuse (14), mount the rope (13) as per scheme 1 and stop it in the stirrup (12)). [In case of sliding door 2 leaves see drawing enclosed] n) In case of electromagnet, mount the rope (13) as per scheme 2 and stop it in the stirrup of the front wheel with the clips. o) Regulate the counterbalance (15) with the plates (16) in equipment. p) Mount the front detention (17), equipped of rubber, and regulate it until the sliding panel is blocked. Maintain 5 mm between the panel and the closing point. q) Install the back detention (18) and weld it to the guide. When completely opened, the panel has to be over the opening. r) Fix the flame labyrinth (18) and following the back steel covering (20) with the screw in equipment (21). s) Mount the gasket (23) and fix the vertical and horizontal flame labyrinths (22). t) Install the electromagnet, the shock absorber and/or continuous shock absorber as per scheme. u) Fix the counterbalance covering (24) with the equipped screws (21). v) Mount the top covering guide (25). In case the covering has made up of more pieces, we suggest to fix it to the stirrups of the covering. 2
3 Standard closing point 3
4 4 Flat closing point (back counterbalance)
5 Sliding door 2 leaves (back counterbalance) 5
6 Scheme Standard closing point Flat closing point Scheme 1 Closing with thermofuse Scheme 2 Closing with electromagnet 6
7 Details A: Mounting of continuous shock absorber B: Mounting of shock absorber C100-C50 C: Regulation of counterbalance D: Mounting/regulation of the wheels 7
8 General Information Do not employ fixed elements to keep the door opened. The opening of the mobile leaf could be maintained only with devices accepted from the manufacturer. Except special agreement while ordering, the doors have to be placed in closed buildings. The cleaning of the surface is performed with cleansers of normal domestic use, avoiding the use of abrasive, aggressive substances or solvents. Usually, doors are painted with finish epoxy at 180. Prior of any further paint, we suggest a deep cleaning of surface with light sand-paper and then application of a primer. In any case the application of nitro varnishes is dissuaded. MAINTENANCE DESCRIPTION. Grease and regulate the wheels Verify that the leaf maintains an height between 5 and 15 mm from floor. On the contrary, make the regulation: take out the upper covering guide (25), unscrew the bolts and regulate the vertical screws. Registration of closing system The working of the closing system by electromagnet is clear. In case of thermofuse (14), uncouple it from its place. If door does not close, verify the mechanism by taking out the covering (26). Check leaf space, check leaf The leaf and the labyrinths must have no deformation, no corrosion, no perforations. Check thermal gasket The thermal gasket must be adherent in all points, see ref. (23). Regulate the self-closing mechanism In case of high speed while closing, check if mechanism is safe, and regulate it (see page 7). Substitute damaged components The accessories for fire proof doors must be bought from specialised dealers. No responsibility in case of improper applications. TIMING DESCRIPTION PERIOD Light usage Medium usage Intensive usage Check self-closing mechanism Each month Check self closing system Check slide mechanism and bad sliding Every six months Every three months Every month Regulation of shock absorbers Verify fixing bolts Every year Every six months Every three months Check electric operator (transmission cable or strap tension and setting tension Every year Every six months Every three months spring, lubricating level, verify surface, e, adherence of the electromagnetic brake) Verify the pads. Verify possible strain lock. Every four years Every two years Every year Check gaskets. Substitute worn parts Substitute damaged or tampered When necessary When necessary When necessary components. As indicative parameters, you could consider the following scheme to identify the type of usage of the door. Light usage = 1-3 daily openings Medium usage = 2-5 daily openings Intensive usage = 4-10 daily openings The above parameters have been calculated on doors with size approx. 16 mq; in case of different size increase or diminish the cycles of opening/closing; for size over 25 mq the daily usage is not proper (we suggest periodic maintenance). The maintenance program must be personalised in case of particular conditions (such us public parking, etc.). In case of sliding doors normally not opening, we suggest a monthly checking of the self-closing system, in order to evidence greater frictions between the mechanical components. La ditta Novoferm Schievano srl si riserva il diritto di modificare in qualsiasi momento le caratteristiche dei prodotti descritti nel presente catalogo. 8
9 1 3 A 2 vista da A
Blind, Sliding, Glazed Doors. Fire Proof Closures
Blind, Sliding, Glazed Doors Fire Proof Closures Elite REI 60 - REI 90 - REI 120 Asia REI 30 Fire proof door type Elite has unique characteristics that clearly distinguish it from traditional fire proof
More informationTable of Contents. B. Base Tool Changer...2 MC-6 Manual Tool Changer...2
Table of Contents B. Base Tool Changer...2 MC-6 Manual Tool Changer...2 1. Product Overview... 2 1.1 Master Plate Assembly... 2 1.2 Tool Plate Assembly... 3 1.3 Optional Modules... 3 2. Installation...
More informationImportant Notice. caution: Use proper lifting equipment and correct procedures to avoid injury.
Integrity. Partnership. Quality. COMMERCIAL DOOR INSTALLATION INSTRUCTIONS SERIES 1900, 1950, 2000, 2250, 2500, 2750 Important Notice In the following text, the word: Warning: Indicates that serious injury
More informationThank you for purchasing our product! *Please read these instructions and follow them step by step.*
07/07/08.rev1 PAGE 1 OF 11 601AL VERTICAL 60120VL LIFT W/CHAIN DRIVE WINCH Thank you for purchasing our product! *Please read these instructions and follow them step by step.* Step 1. Separate and group
More informationASOLA - THETA ISTRUZIONI DI MONTAGGIO FITTING INSTRUCTIONS INSTRUCTIONS DE MONTAGE INSTRUCCIONES DE MONTAJE MONTAGEANLEITUNG. IMPBAT Rev.
ASOLA - THETA I F E D ISTRUZIONI DI MONTAGGIO FITTING INSTRUCTIONS INSTRUCTIONS DE MONTAGE INSTRUCCIONES DE MONTAJE MONTAGEANLEITUNG IMPBAT08-2 - Rev. 00 "THETA" FITTING INSTRUCTIONS SUB-FRAME Correct
More informationHD installation guide
JANUS INTERNATIONAL 1 866 562 2580 www.janusintl.c o m 1950 1950HD installation guide RIGHT DRIVE END SHOWN LH OPPOSITE LEFT TENSION END SHOWN RH OPPOSITE PUSH-UP OPERATION 1950 1950HD SHOWN A rolling
More information400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS
12/11/07 PAGE 1 OF 12 400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS Thank you for purchasing our product! *Please read these instructions
More information9 X 12 FIXED TYPE ALUMINUM WINDOW BARS INSTALLATION INSTRUCTIONS Import Note : 9 X 12 Spacing Fixed Type Installation is covered in this Instruction.
Import Note : 9 X 12 Spacing Fixed Type Installation is covered in this Instruction. Fixed Bars can be Mount in Recess Position ( Between Window Jamb/ Frame )or Surface Mount (Face Of Wall) This Fixed
More informationModel Series T o r s i o n
Model Series 7100 T o r s i o n Residential and Light Commercial Rear Mount Low Headroom Outside Hookup Table Of Contents Pre-Installation 2 Important Safety Instructions 2 Removing an Existing Door and
More informationB. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.
SECTION 081113 - HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standard hollow metal doors and frames. 1.2 SUBMITTALS A. Product Data: For each type of product indicated.
More informationTable of Contents. B. Base Tool Changer...2 MC-16 Manual Tool Changer...2
Table of Contents B. Base Tool Changer...2 MC-16 Manual Tool Changer...2 1. Product Overview... 2 1.1 Master Plate Assembly... 2 1.1.1 Optional Ratchet Knob... 2 1.2 Tool Plate... 3 1.3 Optional Modules...
More informationSINCE 1922 P UBLICATION N O
SINCE 1922 GARED SPORTS MICRO-Z SET-UP INSTRUCTIONS VERY IMPORTANT! READ INSTRUCTIONS CAREFULLY AND FOLLOW STEP BY STEP SET-UP PROCEDURE P UBLICATION N O. 5 5 1 7 5 2 9 1 6 Recommended tools and accessories.
More information300 Series Racks. 19" Wide Opening Stand-Alone Wall Cabinet with Adjustable Rails. Applications. Features. In The Box. Options
300 Series Racks 19" Wide Opening Stand-Alone Wall Cabinet with Adjustable Rails Applications The 300 Series is ideal to house electronic equipment for any type of application, both commercial and residential,
More informationPFT CABLE GYM INSTRUCTION MANUAL
PFT CABLE GYM INSTRUCTION MANUAL QUESTION? As a quality home gym supplier we are committed to your complete satisfaction. If you have questions, or find missing or damaged parts, we will guarantee your
More informationTable of Contents. B. Base Tool Changer...2 MC-36 Manual Tool Changer...2
Table of Contents B. Base Tool Changer...2 MC-36 Manual Tool Changer...2 1. Product Overview... 2 1.1 Master Plate Assembly... 2 1.1.1 Optional Ratchet Knob... 2 1.2 Tool Plate... 3 1.3 Optional Modules...
More informationOPERATION AND MAINTENANCE MANUAL. mcr TLB ECO GATES
ASSA ABLOY Mercor Doors sp. z o.o. ul. Arkońska 6, bud. A2 80-387 Gdańsk tel. +48 58 732 63 00 fax +48 58 732 63 02/03 www.mercordoors.com.pl e-mail: mercordoors@assaabloy.com OPERATION AND MAINTENANCE
More informationPhone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels
Phone # 800-440-8785 www.lajolladoors.com La Jolla Doors Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels Thank you for choosing La Jolla Doors In this manual you will
More informationinstallation guide
JANUS INTERNATIONAL 1 866 562 2580 w w w. j a n u s i n t l. c o m 2000 2500 3000 installation guide RIGHT DRIVE END SHOWN LH OPPOSITE LEFT TENSION END SHOWN RH OPPOSITE PUSH-UP OPERATION 2000 2500 3000
More informationINSTALLATION TORSION SPRING FRONT OR REAR MOUNT LOW HEADROOM. 1 Cutting Vertical Track. 2 Fully Adjustable Jamb Brackets
TORSION SPRING FRONT OR REAR MOUNT LOW HEADROOM Wayne Dalton, a division of Overhead Door Corporation P.O. Box 67, Mt. Hope, OH., 44660 Supplemental insert Copyright 2015 Wayne Dalton, a division of Part
More informationInstalling Your Electronic Deadbolt
Ultra Security Plus Electronic Deadbolt Installation Instructions http://www.hberger.com/video-gallery/electronic-deadbolt New Installation Lock Location Preparation (Skip this section if you door has
More informationRolling Curtain door Manual
Rolling Curtain door Manual Installation Maintenance parts Model 944 PHONE 800 448 8979 FAX 800 236 8722 website www.tracrite.com EMAIL tr@tracrite.com ADDRESS 216 Wilburn Road Sun Prairie, WI 53590 This
More informationHow to operate (folding)
How to operate (folding) LEFT HAND STACKING OUTWARD OPENING How to operate (folding) RIGHT HAND STACKING OUTWARD OPENING LOCK BOTH LEVER HANDLE AND FLAT HANDLE UTILISING THE D-HANDLE LOCATED ABOVE THE
More informationSTEP 1 STEP 2 LEVELER KIT OPTION MOBILE CASTER KIT OPTION
B SERIES INDUSTRIAL BENCHES TOOLS REQUIRED FOR ASSEMBLY Socket set, Open end wrench set, Cordless drill with 3/8" socket bit (Magnetic recommended). BEFORE ASSEMBLY Read through the assembly instructions
More informationDaily Maintenance. 2. Insert bobbin cases in to rotary hooks. Make sure bobbin thread is not over 2 inches long. Close bobbin case covers.
Rotary hook 1. Open bobbin case covers and remove bobbin cases. Use brush to remove lint build up in and around rotary hooks. Compressed air may also be used. Daily Maintenance Cle aning Oiling Rotary
More informationHydrajaws Safety Lifeline Tester
Hydrajaws Safety Lifeline Tester Operating Instructions HYDR AJAWS LIMITED Hydrajaws Safety Lifeline Tester 4 5 1 6 7 2 3 9 10 8 12 11 TECHNICAL SPECIFICATIONS Load Gauges Range available: Analogue: 0-25kN/lb/f
More informationIn-Tube Motorized SCREEN-PRO. All Season Roll-Up Doors IN-JAMB MOUNTING METHOD INSTALLATION INSTRUCTIONS READ THIS FIRST
In-Tube Motorized SCREEN-PRO All Season Roll-Up Doors IN-JAMB MOUNTING METHOD INSTALLATION INSTRUCTIONS READ THIS FIRST Carefully examine the crate(s) for damage before opening. If the carton is damaged,
More informationSTACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS
STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS 1290363 Revision 1 12/16 Page 1 Weather Shield Mfg., Inc. NOTICE CAUTION! Failure to install and maintain our product according to these instructions
More informationInstallation Instructions
Supafold Slide Aside System Three Fold Room Divider Installation Instructions Distinctive Doors Ltd Supafold Slide Aside Internal Folding System IMPORTANT: Before proceeding with the installation, and
More informationHAS MODULAR TELESCOPIC LANDING DOOR INSTALLATION MANUAL
HAS MODULAR TELESCOPIC LANDING DOOR INSTALLATION MANUAL Contents i. Warning and Suggestions... 2 ii. Usage Manuel and Maintenance Instructions... 3 Usage Manuel... 3 Maintenance Instructions... 3 1. Introduction...
More informationSeries 1600 WeatherGuard Dock Enclosure
Fairborn USA Inc. 205 Broadview Street Upper Sandusky, OH 43351 1-800-262-1188 Fax 1-419-294-4980 Series 1600 WeatherGuard Dock Enclosure All Models! WARNING Do not install this product unless you read
More informationOwner s Manual LSP38 38 Lawn Sweeper
Owner s Manual LSP38 38 Lawn Sweeper Manual Contents Safety Instructions Assembly Operation Maintenance Parts Warranty 2 4-13 2 11 14-15 16 Your Lawn Sweeper Congratulations on your purchase of a new Precision
More information3 BRACKET TO GUIDE ATTACHMENT. RIGHT END Figure 1. EXTENDED BRACKET (for doors taller than 8-8 ) SERIES 650. RIGHT END COTTER PIN Figure 6
2 DOOR ARRANGEMENT. A Lay door on a clean floor inside of building and in front of opening (see Figure 1). NOTE: Door can be damaged if laid on unclean surface. B Distribute parts bags, guides, stops and
More informationCRYSTEEL S. this manual must be included with the vehicle after completing the installation.
Website: www.tbei.com E-mail: sales@tbei.com CRYSTEEL S Grain Tipper mounting and operating instructions this manual must be included with the vehicle after completing the installation. Web Site E-Mail
More information9 X 9 REMOVABLE TYPE ALUMINUM WINDOW BARS INSTALLATION INSTRUCTIONS Import Note : 9 X 9 Spacing Removable Type Installation is covered in this
Import Note : 9 X 9 Spacing Removable Type Installation is covered in this Instruction. Removable Bars Only Mount in Recess Position ( Between Window Jamb/ Frame ) The spacing between horizontal bars is
More informationCRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:
CRCODE-202 Mechanical Lock Instruction and Programming Manual Before Installing: 1. Please read the instructions carefully to prevent missing important steps. *Note: Improper installations may result in
More informationCopyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax
Copyright 2003. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 JULY 2003 RM3010A RM315-R2 RM323-R2 RM329 RM451 RM457 RM3020A RM316 RM324-R2
More informationMODEL 2EA/2EB DOOR INSTALLATION INSTUCTIONS
Dover Roller Shutters wants to THANK YOU for your purchase of the 2EA/2EB Aluminum Roll-Up Door! BEFORE INSTALLATION Please carefully read the instruction manual completely. Carefully unpack the contents
More informationSPIDA SAW OPERATIONS MANUAL
SPIDA SAW OPERATIONS MANUAL CM SERIAL NUMBER. OCTOBER 2000 CONTENTS Page description 1.) Contents 2.) Safety First 3.) CM Overview 4.) CM Specifications 5.) CM Installation 6.) CM Operation Setting the
More informationPassive Panel Replacement
Passive Panel Replacement Product Series: 200 Series Product Type: Hinged Inswing Patio Doors Read these instructions before starting procedure. For additional information visit www.andersenwindows.com.
More informationRepair manual. Fifth-wheel coupling JSK 38/50
Repair manual Fifth-wheel coupling JSK 38/5 ZDE 199 3 12 E 6/212 1 Foreword Table of contents Page Fifth wheel couplings are connecting parts that must comply with very high safety requirements and must
More informationFixed Upper Sash Replacement Guide for Andersen 400 Series Woodwright Springline Single-Hung Windows
Fixed Upper Sash Replacement Guide for Andersen 400 Series Woodwright Springline Single-Hung Windows Manufactured Between September 2005 and October 2006 Read all instructions carefully before attempting
More informationN35 ALUMINIUM ROLL-UP DOOR INSTALLATION MANUAL
N35 ALUMINIUM ROLL-UP DOOR INSTALLATION MANUAL DOVER ROLLER SHUTTERS 295 COMMERCE WAY P.O. BOX 420 UPPER SANDUSKY, OH 43351 Dover Roller Shutters wants to THANK YOU for your purchase of the N35 Aluminum
More informationThis product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 80psi (550 kpa) maximum.
We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start installation. If you encounter any installation or performance problems, please don t hesitate
More informationOPERATION AND MAINTENACE MANUAL. mcr ALPE EI 120
ASSA ABLOY Mercor Doors sp. z o.o. ul. Arkońska 6, bud. A2 80-387 Gdańsk tel. (58) 732 63 00 fax. (58) 732 63 02/03 www.mercordoors.com.pl e-mail: mercordoors@assaabloy.com OPERATION AND MAINTENACE MANUAL
More informationsouthpaw enterprises, inc.
Eye Bolt Wrap 7001 Store these instructions with the enclosed maintenance checklist in a safe place. You may also access them on our website. this in an accessible location: the must be read and familiar
More informationC. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.
SECTION 105113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationHeavy and Medium Duty Fire Doors
Heavy and Medium Duty Fire Doors 10 06.06.2011 Add. Section 1.4. JES VK 09 14.12.2009 New doc. Frontpage JES VK 08 29.11.2006 Page 8 and 13 revised JES VK 07 08.11.2006 Page 15 revised JES VK 06 08.03.2005
More informationACORNWIRE.COM MESH PARTITIONS DIVISION 10 - SPECIALTIES WIRE MESH PARTITION FOLDING GATE
acorn WIRE ACORNWIRE.COM MESH PARTITIONS DIVISION 10 - SPECIALTIES 10 22 13 WIRE MESH PARTITION 10 22 16 FOLDING GATE GUIDE Page 4 / 5 No. 130A All wire type for normal industrial use. 7, 8, 9, 10 and
More informationInstallation Instructions for Vista Air Vertically Folding Walls
Installation Instructions for Vista Air Vertically Folding Walls Use these instructions in conjunction with your shop drawings to see the specifics that are particular to the model you are installing.
More informationInstallation Guide Installation Kit for Mounting Philips MP20/30/40/50 on Datex-Ohmeda Aisys Anesthesia Machine
Installation Guide Installation Kit for Mounting Philips MP20/30/40/50 on Datex-Ohmeda Aisys Anesthesia Machine The purpose of this guide is to: 1. Describe mounting of Counterweight (page 2). 2. Describe
More informationMidmark Care Exchange 6282 Standard Duty Wall Mounted Workstation
INSTALLATION MANUAL Midmark Care Exchange 6282 Standard Duty Wall Mounted Workstation Weight Capacity 5-20 lbs 1210180MD Rev. C TABLE OF CONTENTS Tools Required / Installation Warnings / Disclaimer / Safety
More informationMIRAGE-X / BELLA. Shower Door Installation Instructions
MIRAGE-X / BELLA Shower Door Installation Instructions IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical
More informationINSTALLATION MANUAL GIOTTO SCREEN
INSTALLATION MANUAL GIOTTO SCREEN Before installing the Giotto screen, please read the following instructions carefully: The Giotto screen must be used INDOORS ONLY. It is forbidden to stay under the Giotto
More informationVinyl Windows and Doors Manufactured by VPI Quality Windows
Vinyl Windows and Doors Manufactured by VPI Quality Windows Part Number: 511_Installation ENDURANCE CASEMENT\AWNING\PW INSTALLATION INSTRUCTIONS Installation Instructions for Typical Construction These
More informationREAD CAREFULLY - FAILURE TO FOLLOW INSTRUCTIONS AND SAFETY RULES MAY RESULT IN SERIOUS INJURY
Owner s Manual LSV50120B LS5000B leg bundle LS5021B post bundle LS5022B cradle bundle V50120B straight LS5003B spreader bundle LS5004B bunk bundle LS4005B accessory box LS2005B wheel LS5007B diag bundle
More informationEnglish. Operating manual. Tipping bucket rain gauge HD Keep for future reference. Companies / Brands of GHM
English Operating manual Tipping bucket rain gauge HD2015 Companies / Brands of GHM www.deltaohm.com Keep for future reference. TABLE OF CONTENTS 1 INTRODUCTION... 3 2 TECHNICAL CHARACTERISTICS... 4 3
More informationSpring Loaded SCREEN-PRO. All Season Roll-Up Doors IN-JAMB MOUNTING METHOD INSTALLATION INSTRUCTIONS READ THIS FIRST
Spring Loaded SCREEN-PRO All Season Roll-Up Doors IN-JAMB MOUNTING METHOD INSTALLATION INSTRUCTIONS READ THIS FIRST Carefully examine the crate(s) for damage before opening. If the carton is damaged, immediately
More informationSash Replacement Guide for Andersen 400 Series Tilt-Wash Transom Windows
for Andersen 400 Series Tilt-Wash Transom Windows Read all instructions carefully before attempting this procedure. If you have any questions about your ability to complete this procedure, call Andersen
More informationPlease read and understand the OnBoard Timpani Cart Owner s Manual before using the Timpani Cart.
Assembly and Owner s Manual OnBoard Timpani Cart Performance Position Towing Position CONTENTS Important User Information...........................2 General......................................2 Manufacturer.................................2
More informationH B K A Symbol Shape Material Article Description Article Nr. kg/eh L svz vrame fire 8050L-FI ,60 36
H B K A Symbol Shape Material Article Description Article Nr. kg/eh mm mm mm mm VE vrame fire 80 (EI90) 80 50 20 L svz vrame fire 8050L-FI90 646613 6,60 36 80 50 20 T svz vrame fire 8050T-FI90 648913 6,95
More informationINSTALLATION MANUAL FORTRESS SERIES
Guardian Security Structures TEL 1-406-212-2334 EMAIL rg@gssdoors.com WEB www.gssdoors.com FORTRESS SERIES GENERAL INSTALLATION GUIDELINES 1. The door frame is installed using 16 bolt screws 7,5 mm in
More informationBREAK-OUT SYSTEM FOR SLIDING DOOR ASSEMBLED MANUAL
ENGLISH BREAK-OUT SYSTEM FOR SLIDING DOOR ASSEMBLED MANUAL KBSE1 KBSD1 SLIDING DOORS BREAK-OUT SYSTEM SIDE WALLS BREAK-OUT SYSTEM FACE S.p.A. Viale delle Industrie, 74-31030 Dosson di Casier (TV) - Italy
More informationESA-300 Full Breakout
Interior View 0 Installation Instructions For use with ESA II Controler DORMA AUTOMATICS, Inc. 94 Sherwood Drive Toll-Free: 877-67-6 DL844-00 Lake Bluff, IL 60044 Fax: 877-4-7999 Rev. /07 Tools Required:
More informationGared Pro-S Portable Backstop
Models: 9616 & 9618 Installation, Operation and Maintenance Instructions Please read all instructions before attempting installation or operation of these units SAVE THESE INSTRUCTIONS FOR FUTURE USE PUBLICATION
More informationUltimate Products, Inc.? 2319 Laurelbrook Street? Raleigh, NC 27604? USA Toll-Free: (800) ? Fax: (919)
Illuminator Door Installation & Maintenance Guide Ultimate Products, Inc.? 2319 Laurelbrook Street? Raleigh, NC 27604? USA Toll-Free: (800) 542-7221? Fax: (919) 834-4526 www.ultimate-product.com Table
More informationS E L E C T I O N. Arm Curl. User manual
S E L E C T I O N T H E S T R E N G T H E V O L U T I O N User manual The identification plate of the and manufacturer, affixed behind the seat, gives the following details: A Name and address of the manufacturer
More informationFifth-wheel coupling JSK 38/50
Repair manual Fifth-wheel coupling JSK 38/5 ZDE 199 3 12 E 6/25 1 LT SK38C-3 English RevA Foreword Table of contents Page Fifth wheel couplings are connecting parts that must comply with very high safety
More informationK15.12 ROLLENBAND K15 DOORS
K15 DOORS 01.04.2015 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. General characteristics....03 2. Application range....03
More informationINSTALLATION, OPERATION, LUBRICATION, AND MAINTENANCE OF NO. S B18 AND B24 SMOOTH ROLL CRUSHERS
INSTALLATION, OPERATION, LUBRICATION, AND MAINTENANCE OF NO. S B18 AND B24 SMOOTH ROLL CRUSHERS I. INSTALLATION A. RIGID MOUNTING: Use two heavy WF or I-beams running parallel underneath at least eight
More informationGLOSSARY OF TERMS SECTION 8
GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the
More informationPanel Assembly and Installation
Assembly and Installation Assembly and Installation for Andersen 400 Series Frenchwood, 200 Series Narroline, 200 Series Perma-Shield Gliding Patio Doors and 400 Series Perma-Shield Gliding Patio Doors
More informationThese Installation Instructions are valid for antennas in the following version:
Installation Instructions 4 ft CompactLine Antennas (with E-Mount 200 km/h) SB, SBX NMT 480-12(e) These installation instructions have been written for qualified, skilled personnel. The antenna shall be
More informationREAD CAREFULLY - FAILURE TO FOLLOW INSTRUCTIONS AND SAFETY RULES MAY RESULT IN SERIOUS INJURY
Owner s Manual LSV50120B LS5000B leg bundle LS5021B post bundle LS5022B cradle bundle V50120B straight LS5003B spreader bundle LS5004B bunk bundle LS4005B accessory box LS2005B wheel LS5007B diag bundle
More informationModel 7100 Series. T o r s i o n, R e a r M o u n t L o w H e a d r o o m
Model 7100 Series T o r s i o n, R e a r M o u n t L o w H e a d r o o m Residential and Light Commercial Quick Start Guide Table Of Contents Pre-Installation 2 Important Safety Instructions 2 Door Section
More informationPHONE: FAX:
Models: SB-12600, SB-12600C, SB-12601, SB-12680, SB-126801, SB-12682, SB-12683, SB-12720, SB-12720C, SB-12760 1... BI-32018... Paper Bag, type SUB-3, 3 pack 2... BI-5554431... Handle Tube, w/ grip 2...
More informationPlease read these instructions before use and keep for future reference
Wardrobe Assembly Guide Allen Key Provided (if required) Philips Screwdriver Required Hammer Required Please read these instructions before use and keep for future reference Caution! Two Person Assembly
More informationInstallation - Sub Cills
Installation - Sub Cills Fitting of Subcill Drainage paths through the sub-cill can be seen on the illustration alongside so care must be taken to ensure they are not obstructed and that screw fixings
More informationINSTALLATION LOW HEADROOM EXTENSION. 1 Cutting Vertical Track. 2 Quick Install Jamb Brackets
LOW HEADROOM EXTENSION P.O. Box 67, Mt. Hope, OH., 44660 Supplemental insert Copyright 2016 Wayne Dalton, a division of Part No. 333897 REV3 5/03/2016 This supplemental installation instruction is to be
More informationProfiles for floors of same height Proclassic Proclassic F
PROFILPAS S.P.A. VIA EINSTEIN, 38 35010 CADONEGHE (PADOVA) ITALY TEL. +39 (0)49 8878411 +39 (0)49 8878412 FAX. +39 (0)49-706692 EMAIL: INFO@PROFILPAS.COM Profiles for floors of same height Proclassic Proclassic
More informationB. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.
SECTION 081113 - HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standard hollow metal doors and frames. 1.2 SUBMITTALS A. Product Data: For each type of product indicated.
More informationINSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS
2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed
More informationAssembly instructions
Assembly instructions SF 55 / SF 55c SF 75 / SF 75c / SF 75H A B B C D Scope of delivery: Safety instructions: A. Top rail B. Vertical profile C. Floor rail D. Hinged panel, sliding panel Accessories pack
More informationHow To Measure Your Finished Opening
3000 Series Bifold Doors How To Measure Your Finished Opening MEASURE FROM RIGHT TO LEFT 2 PLACES (WIDTH) MEASURE FROM TOP TO BOTTOM 2 PLACES (HEIGHT) Tools Required for Assembly: Tools Needed: Phillips
More informationHENDERSON. Securefold R-Loc Non-Mortice 100kg. Fitting Instructions for top hung exterior folding doors with NON-MORTICE HINGES SYSTEM CAPACITY
1 HENDERSON Diagram 1 TRACK FIXING (NOT BY PCH) Securefold R-Loc Non-Mortice 100kg Fitting Instructions for top hung exterior folding doors with NON-MORTICE HINGES SYSTEM CAPACITY Maximum leaf height-
More informationCare Instruction: Wash vehicle roof prior to installing Rhino Tracks.
Important: Please read these instructions carefully prior to installation. Please refer to your fitting instruction to ensure that the roof racks are installed in the correct locations. Check the contents
More informationSECURIFIL Gleeson Roofing Supplies LTD
SECURIFIL Gleeson Roofing Supplies LTD End part SECURIFIL Alu Reference: A1 End part in alu, to assemblee on adapt plate or post, being useful to fixe the life-line cable and its accessories. flat roofs,
More informationFront axle components, overview
j a t Front axle components, overview 40-1 General Information Load bearing components and parts of the suspension must not be welded or straightened. Vehicles without drive axle must not be moved, or
More informationICU TRACKLESS SLIDING DOOR
Interior View 0 Installation Instructions Tools Required: Screwdrivers Small Straight (Flat Blade) - for Terminal Block wiring # Phillips (Crosspoint) - for various #8, #0, and #4 screws Wrenches / Sockets
More informationHawko LED Flex & Accessories Installation Instructions
LED Flex & Profiles Hawko LED Flex & Accessories Installation Instructions Contents Installation of IP20 LED Flex 4 Installation of IP67 LED Flex 6 Mounting Channel Installation 8 Mounting Clip Installation
More informationCROWN IMPERIAL ASSEMBLY INSTRUCTIONS
CROWN IMPERIAL ASSEMBLY INSTRUCTIONS Standard Drawer Box Page 1 of 14 Standard Drawer Box Parts Parts Supplied B C D A E F G Page 2 of 14 Part Letter Part Name Quantity 300-600 Deep Pan A Base Panel 1
More informationREAD CAREFULLY - FAILURE TO FOLLOW INSTRUCTIONS AND SAFETY RULES MAY RESULT IN SERIOUS INJURY
LSV30108C LS5002C cradle bundle 108 LS5004B bunk bundle LSV40108C LS5002C cradle bundle 108 LS5004B bunk bundle LS5007B diagonal bundle LSV30120C LS5012C cradle bundle 120 LS5004B bunk bundle LSV40120C
More informationInstallation Guide. Rockfon Eclipse
Installation Guide Rockfon Eclipse GENERAL INFORMATION System description: Rockfon Eclipse is a frameless acoustic island made from a 40 mm bevel edged stone wool panel. The visible side is covered with
More informationModels 105, 110, 106, 116, 310, 311, 314 and 316
Models 105, 110, 106, 116, 310, 311, 314 and 316 T o r s i o n Residential and Light Commercial Standard Lift Installation Instructions And Owner s Manual DEFINITION OF LIGHT COMMERCIAL: 1. Door Heights
More informationImportant Notice. CAUTION: Use proper lifting equipment and correct procedures to avoid injury.
Integrity. Partnership. Quality. SELF-STORAGE DOOR INSTALLATION INSTRUCTIONS SERIES 690 Important Notice In the following text, the word: Warning: Indicates that serious injury or death can result from
More information6400, 8400 and 9400 Series Sliding Patio Door
Contemporary 3 Panel Classic 5 Panel French Panel 6400, 8400 and 9400 Series Sliding Patio Door (O) Fixed Panel Left (X) Operating / Mullion Panel Right (X) Operating / Lock Panel Left (O) Fixed Panel
More informationIPA BESLAG FOR SCHÜCO ALU INSIDE NORDIC A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45)
IPA BESLAG FOR SCHÜCO ALU INSIDE NORDIC 2015 A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45) 98 35 15 00 3 FITTINGS FOR SCHÜCO ALU INSIDE NORDIC Table of contents PAGE SCHÜCO
More informationSide and rear window, assembly overview
64-7 Side and rear window, assembly overview 1 - Side/rear window Removing Unbroken Page 64-9 Broken Page 64-11 Installing Page 64-13 Curing time Page 64-21 Re-sealing Page 64-25 2 - PUR adhesive sealant
More informationSECTION HOLLOW METAL DOORS AND FRAMES
PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 08 11 13 HOLLOW METAL DOORS AND A. Non-fire-rated hollow metal doors and frames. B. Hollow metal frames for wood doors. C. Fire-rated hollow metal doors and
More informationProfiles for wooden and laminate floors Unisystem Plus - Unisystem
PROFILPAS S.P.A. VIA EINSTEIN, 38 35010 CADONEGHE (PADOVA) ITALY TEL. +39 (0)49 8878411 +39 (0)49 8878412 FAX. +39 (0)49-706692 EMAIL: INFO@PROFILPAS.COM s for wooden and laminate floors Unisystem Plus
More informationOperating Manual. for CUTTING, PERFORATING, BENDING SLB120
Operating Manual for CUTTING, PERFORATING, BENDING SLB120 31040\B06eng 0896 0 Contents 1. Scope of delivery... 1 2. Technical specifications... 1 3. Applications... 1 4. Commissioning... 2 5. Cutting...
More information