NSL-10 STANDARD LIFE MODULAR CAPACITORS

Size: px
Start display at page:

Download "NSL-10 STANDARD LIFE MODULAR CAPACITORS"

Transcription

1 ADVANCE P.F. CORRECTION SOLUTIONS FROM NEPTUNE-DUCATI Channel Partner Ph: , Industrial Trading Co. 10B Dharma Super Market, Kim Char Rasta, Contact : Paresh Gandhi ( ) Fax: , itcsurat.sales@gmail.com N H No 8, Dist: Surat , Guj, India

2 NSL-10 STANDARD LIFE MODULAR CAPACITORS Because of their modular construction, NSL10 capacitors are particularly suitable in the production of automatic power factor correction systems. They are also used in power factor correction of motors and transformers. The NSL10 threephase capacitor is made with three single-phase capacitors. The three switch-on reactors are made of copper windings. The external case, made with insulating material, (Class V2 according to UL 94 standard flammability classification) eliminates the need to provide a protective earthing connection. The easy assembly using "small feet" make the capacitor a universal one. 1) Capacitive elements provided with a sensitive "FLOPPY CAP" over pressure protection device - low loss metallized polypropylene film as dielectric, impregnated with polyurethanic resins. 2) Excellent dissipation of the internally - generated heat. The triple round - vertical structure improves the heat dissipation are for a better cooling of the internally-fit modules are used. A lower dielectric means an extended life expectancy of the capacitor. 3) The Modular design permits a most simple mechanical assembly - No extra accessory metal-parts are required. Electrical connections are made by copper-links available on request. Total Modularity New Assembling System Dry Type Low Losses Non Polluting Double Protection Safety Device Standard Voltage (Un) : 440/450V Other Voltage on request (Un) : 415V - 550V Rated frequency : 50 Hz Capacitance tolerance : % A.C. test voltage bet. terminals : 2, 15 Un per 10" A.C. test volt. bet. terminals & case : 3 kv per 10" Installation : Internal Ambient air temperature category : C Altitude : < 2000 m Service : Continuous Protection degree : IP 40 Discharge resistor : Internal (50V after 1 min) Maximum permissible current : 1.3 In maximum Terminals : 3 x M 8 Dielectric losses : < 0.3 W/kvar Reference standard : EN /2 NSL-10 MODULAR TYPE HEAVY DUTY CAPACITORS NEPTUNE-DUCATI NSL-10 HD range for use in the power factor correction of industrial & office electrical networks. It is a series of quality products which has been designed to cater to the most demanding users where operating conditions are particularly critical and where reliability is of prime importance. The NSL-10 HD range also satisfies the demand for a product with durability and longer life. Total lack of air between the capacitors plates ensures that the dielectric - and hence the capacitor too-lasts a long time. The dielectric consist of heavy films of polypropylene. The capacitors are designed with a very low loss dielectric & high quality film is used. They combine these high-tech advantages with the safety and reliability of the traditional technology of impregnation used for Medium Voltage capacitors. The capacitive elements are housed in a cylindrical container made of aluminum. All of the materials employed are non-toxic and biodegradable. Thanks to the above characteristics, the capacitor has an expected life which greatly exceeds 1,00,000 hours. It is characterized by the capability of bearing high harmonic components up to R.M.S. Currents level in excess of 2 In. Total Modularity New Assembling System Oil Impregnated Low Losses Operation life>1,00,000 hrs Double Protection Safety Device Standard Voltage (Un) : 440/450V Other Voltage on request (Un) : 415V - 550V Rated frequency : 50 Hz Capacitance tolerance : % A.C. test voltage bet. terminals : 2.15 Un per 10" A.C. test voltage bet. terminals & case : 3 kv per 10" Installation : Internal Ambient air temperature category : C Altitude : < 2000 m Service : Continuous Protection degree : IP 30 Discharge resistor : Internal (50V after 1 min) Maximum permissible current : 2 In maximum Terminals : 3 x M 8 Dielectric losses : < 0.3 W/kvar Reference standard : EN /2

3 MG UNIT-PLATE MOUNTED LL-10/NSL-10 FLOPY CAP UNITS Neptune-Ducati MG Units offer the same advantages & features as at of LL-10 / NSL-10 and have been specifically designed for fitting in APFC Panels. They not only offer space saving, easy installation but better life then enclosed and 3 phase cylindrical capacitors. Safety cap is provided on terminals of each cell & main terminals for protection. The placement of an insulating container between the capacitor element and the metal case, combine with the embedding of the capacitor element in resin, make the capacitor extremely safe from both an electrical point of view (ground insulation) and in terms of resistance to vibrations. All capacitors are equipped with a safety device conforming to EN /2. Space Saving With Terminal Protection Resistance to Vibration Mountable in APFC Panel Easy Installation Easy Maintenance This safety feature has been devised using a special (patented) constructive technique; if a fault occurs, the device breaks both the connections, leaving the insulation of the case intact and preventing the capacitor from exploding or burning. In the event of a permanent short circuit, the current causes the dielectric to decompose and form gas: the resulting buildup of pressure pushes up the part of the lid where the terminals are mounted, thus breaking the internal connections and stopping the flow of current. The device is designed and duly dimensioned for each size of capacitor to ensure the most effective and fastest interruption with both high and low short circuit currents (up to 10,000 A). Standard Voltage (Un) - 440/450 V Other Voltage on request (Un) - 415V- 550 V Rated Frequency - 50 Hz Capacitance Tolerance % A.C. Test Volt. between terminals Un x 10 A.C. Test Volt. between terminals - 3kV x 10 and enclosure Installation - Internal 0 Ambient air temperature category C Temperature Class - -40D Altitude - < 2000 m a.s.l.. Service - Continuous Discharge Resistor - 10% of Un in 20 sec. Maximum permissible current - 4 In maximum Connection - Delta Limiting Reactors - NIL Terminals - 3 x M6 (upto 30 KVAR) Terminals - 3 x M8 (above 30 KVAR) Dielectric losses - < 0.3W/kvar Standards - EN /2 MODULO50 LONG LIFE LL-10 CYLINDRICAL CAPACITOR BANK Neptune-Ducati LL-10 Mono16 or Long Life Modulo50 series - the capacitors making up the new series MONO16 / MODULO50 are manufactured using elements wound with the new PPMh film and housed in metal cases with metal lids. The parts are assembled by crimping to ensure perfect airtightness of the system and efficient operation of the over pressure safety device. The use of oil impregnation technology greatly enhances the capacitor s performance in terms of heat dissipation as well as ensuring a long life and excellent ground insulation. This series is used in practically all Ducati energia power factor correction systems (fixed or automatic) which rely on single-phase capacitors. In fact, the abovedescribed characteristics make these capacitors especially suitable for continuous duty under highly demanding conditions inharmonic rich environments. Standard Voltage (Un) V Rated Frequency - 50 Hz (60 on request) Capacitance Tolerance % Dielectric Losses - < 0.2 W/kVAr Altitude - < 2000m a.s.l. Duty - Continuous Voltage range V Protection rating - IP 00 Test Volt. (AC) between terminals - 2,15 Un x 2 s Test Volt. (AC) between terminals - 3kV x 10 s and case Temperature class - -25/D Terminals - Double faston (M5 bolt for Q > 8.33 kvar Max. inrush current In Max overload In - 4 x In Life expectancy - > h - 25/D > h - 25/C Max dv/dt - < 100 V / s Standards - IEC _

4 HARMONIC CIRCUIT FILTER REACTORS FOR LOW VOLTAGE Copper Winding High Linearity H-Class Insulation Low Temperature Rise Low Losses Vacuum Impregnated Applications Harmonic generated by non-linear loads such as variable speed drives or other static power conversion equipment have grown rapidly in recent years. Harmonic currents and the voltage distortion, created by these currents have devastating effects on power supply and distribution systems and its connected loads. This can result in failure of power factor correction capacitors due to overloading, system resonance, overheating of cables and transformers as well as misoperation of PLC s, computer and other sensitive applications. A present method to treat harmonic problems is the use of filter circuit reactors combined with power capacitors in detuned and tuned filters. As well as the improvement of the power factor and the power quality, harmonics are also absorbed from the networks. Furthermore, a critical amplification of the current harmonics caused by a parallel resonance between the power capacitors and the inductances of the power supply system can be avoided. Dimensioning The dimensioning of the filter circuit reactors is based on the recommendation of allowable limits of voltage harmonics in public and industrial networks according of IEC In case of higher harmonic loads in networks, special designed filter circuit reactors have to be used. The actual loads can be detected by means of a harmonic analysis. The measured values from the basis for the dimensioning of the filter circuit reactors. Design Features Neptune filter circuit reactor are designed as three-phase reactors with an iron core and air gap. Harmonic Filter Reactors are made out of highest quality material and very stringent quality control. It has been designed with properties like low temperature rise and lower flux density so that it can operate in worst conditions of ambient and harmonic overloads. They offer very good degree of linearity. Cheaper and non-linear reactors may trigger undesirable chain phenomena during periods of operation with high harmonic values, such as reducing in the inductance with consequent increase in the resonance frequency of the LC group, which would drain off more harmonic current, further reducing its inductance and overload the reactor more and more. Reactors are available with filtering factor of 5.6%, 7% and 14% in 5, 7.5, 10, 12.5, 15, 20, 25, 50, 75 and 100 KVAr rating.any other filtering factor and rating can be made on request. Losses The 50 Hz losses are comparatively low but when the filter circuit reactors are installed into the cabinets, they are charged with additional currents, predominately those of the 5th, 7th & 11th harmonics. Then the total heat losses dissipated can be of a level whereby they have to be extracted from the cabinets, by means of fans. Terminals The terminals for filter circuit reactors are designed as cable terminals (d=8,5mm). Rated Voltage : 3 x 415/440V Rated (KVAr) : kvar Frequency : 50 Hz Constructional Max. Voltage : 1000 V Test Voltage : 5000 V Filtering factors / Tuning freq. : 5.6% (210 Hz), 7% (189 Hz) & 14% (133 Hz) Tolerance of inductance : ±3% Linearity (L> 0.95 x Ln) : 200% o Ambient temperature + 55 C Winding material : Cu Insulation class : H Cooling method : Natural cooling (AN) Installation : Indoor Protection degree : IP 00 Operating altitude : 1000m above sea level at rated operation o Temp. sensor (normally closed) : 155 C Reference standard : IEC

5 AUTOMATIC POWER FACTOR CONTROLLER - RM RM Power Factor Controllers are used for measurement and control of power factor control units for central reactive power compensation. The Power Factor measured by Neptune RM is compared with the set values and in order to provide necessary compensation. Power Factor Controller switches capacitor banks ON and OFF automatically. RM is 1-phase micro controller relay, designed for above application in 144x144 case for flush mounting with rear plug-in connectors. In addition, Neptune RM displays the following values. NEPTUNE 1) Power Factor 2) Cos phi 3) Phase-Phase voltages (VAC) 4) 1-Phase current (I) 5) 1-Phase active power (W) 6) Total active power (IW) 7) 1-Phase reactive power (Var) 8) 3-Phase apparent power (VA) Measurement of A,V,PF,CosPhi,W,VAr,VA Compensation for Reactive Power Auto/Manual modes selector Automatic calculation of C/k value Designed to use with current transformer Program entry for targeted cos phi value CONTROL AND MENU OPERATIONS All settings are made through the Menu. The set values, except operating mode are kept in memory even if the device is switched off. When it is switched on, it starts compensation with the values stored in the memory in Automatic Operating Mode. After entering Menu, if you don t make any adjustment during 20 seconds, RM operates with the previously stored values. To quit Menu, UP-DOWN buttons are pressed until the ESC symbol is displayed and then SET button is pressed. RM Series Microcontroller based programmable RM series relays are manufactured with 8 and 12 capacitor steps. They are designed 144x144 mm case for flush mounting with rear plug in connectors. It can work either in automatic or manual mode. NAAC-3P Series are ultimate solution for compensation of unbalanced loads. Further to RM series standard features, NAAC-3P series controllers function as if a reactive energy meter. The Compensation is realized by measuring the reactive power of system, through 3 current transformers from 3 phases. This makes NAAC-3P Series a unique solution for unbalanced load compensation. Features (RM Series & NAAC-3P Series) > Measurement of A,V, PF, Cos phi, W, VAr, VA > Compensation for Reactive Power > Automatic /Manual mode selection with indicator light > Automatic calculation of C/k value > Program entry for targeted cos phi value > Number of capacitor steps are user definable > The consequent switching time between capacitor steps is adjustable from 2 to 50 seconds > C+NORMAL/C-condition lights indicate actual system state > Over Voltage, Insufficient Compensation, Over Compensation state alarm indicator lights with output contact > Adjustable programmable Over Voltage protection for capacitor blanks > Micro controller based digital design complying with international standards > For flush mounting with rear panel connectors > Designed to use with current transformer (.../5A) Technical Data (for RM Series & NAAC-3P Series) Power supply : 220,230, 240 VAC (Phase-Neutral) 380, 400, 415V AC (Ph.-Ph.)± 10%, 50 / 60Hz (optional) Operating current :../5A, 100mA to 5.5A Setting Range : 0, 85< cos phi <1 (inductive) Manual C/k: ( ), CT ratio: Accuracy : Class 2% + 1 Digit (For NAAC-3P series) Class 1% + 1 Digit (for RM Series) Connection type : terminals Power consumption : <2 VA (Current circuit) <3 VA-10VA (Voltage circuit) Type : balanced compensation upto 3- Phases, 4 wires (RM series) Unbalanced Compensation upto 3-phase, 4 wires (NAAC-3P Series) No-Volt Release Feature : Automatic disconnection of all Capacitor steps in case of mains failure over 200 ms Output contacts : 5 12x@ 3A, 750VA Time Delay : Switch on: 2-50s Switch off: 2-50s Operating range : -5 C; +55 C Storage range : -25 C; +70 C Relative humidity : 95% Protection class : IP20 (for front panel) Equipment protection : Double Insulation ( ) Standards : CE Dimensions : Type PR16, Type PR 19(only RM Switchboard Cutout : 139x139mm (PR16), 90x90mm (Pr19) Cable diameter (for terminal): 2.5mm2 Installation : Flush-mounting with rear terminals Weight : 0.8 kg

6 AUTOMATIC POWER FACTOR CONTROLLER - RMI The new digital RMI series not only offers a high reliability and accuracy in the wattless power compensation but also a user interface for the configuration and programming, which is extremely evident and suitable to all applications. The new microprocessor also permits a better management of the innovative functions implemented. Automatic reactive power control relays are microprocessor controlled systems that automatically manage capacitor banks to compensate for the reactive power absorbed by the load. The following versions are available: - RMI family available in a 144 x 144 mm with 7 and 12 output relays, and 96 x 96mm with 5 output relays. Capacitor banks are switched on and off as the capacitive reactive power required to reach the set value of the load cosj in the regular exceeds 70% of the power of the first bank for a time corresponding to the set delay. Long term memory for settings Three-Phase LED display Self programming function for power stages Can check health of Cap. Bank connected Fully static units controlled Measuremnt of network harmonics These generation control relays also offer Measurement, Protection and Data Acquisition for PC Transmission and Storage (RMI-7-12 only). The RMI-7-12 version can perform net data communication by means for Ducati instruments / analyzers. Automatic reactive power control relays are microprocessor controlled systems that automatically manage capacitor banks to compensate for the reactive power absorbed by the load. The most innovative features are: - 3 logics to connect/disconnect banks, with automatic recognition: - Universal geometric logic (1 :2 :4), in which it is possible to obtain a high number of steps, while minimizing the number of banks; - Circular and linear logic (1: 1: 1), in which the output relays are controlled in a circular sequence, thus allowing a more even distribution of operations on contacts and considerably reducing maintenance required; - Semicircular and linear logic (1:2 :2), in which it is possible to obtain a higher number of steps than the logic (1 : 1 : 1). The PROTECTION SYSTEM which protects p.f. correction includes: - Over voltage alarm activated even when no bank is connected; it protects the regulator from any overvoltage which is higher than the allowed one, that is more than 30 seconds; - Over temperature protection which is active even when no capacitor bank is on; it is tripped when the air temperature around the control relay exceeds the limit for at least 15 seconds; - Harmonic overload protection which protects the capacitors from peak voltages; - Power Factor Correction Fault which indicates that the cos value remains below the set value for more than two hours, while all banks are switched on; - No voltage protection which cuts out relays when there is no voltage for more than two periods. When power voltage is back, the control unit will operate under automatic control. NEPTUNE (INDIA) LTD. Sales & Marketing Office : K-1/12, Chittaranjan Park, New Delhi (INDIA) Tel.: , 40, 50 Fax: enquiry@neptuneindia.com Corporate Office : C-270, SFS Sheikh Sarai, Phase-I New Delhi (INDIA) Tel.: Fax: neptune@del2.vsnl.net.in

Mounting Instructions / Manual MV1171

Mounting Instructions / Manual MV1171 Mounting Instructions / Manual MV1171 POWER FACTOR Controller ESTAmat MH-N Vishay Electronic GmbH ESTA Capacitors Division Revision: 19-April-2011 Hofmark-Aich-Strasse 36 84030 Landshut, Germany Phone

More information

Power factor correction and harmonic filtering. Automatic power factor regulators

Power factor correction and harmonic filtering. Automatic power factor regulators Power factor correction and harmonic filtering Automatic power factor regulators Automatic power factor reguladors R.1 - Automatic power factor regulators Selection table R1-4 computer Plus-T Intelligent

More information

Reactive Energy Management

Reactive Energy Management Energy management Reactive Energy Management Low Voltage Components Catalogue 2010 Reactive Energy Management Main contents Power Factor Correction guideline 2 Low Voltage capacitors 3-9 Detuned reactors

More information

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design

More information

DATA SHEET POWER CAPACITOR

DATA SHEET POWER CAPACITOR Issued August 2009 10470 DATA SHEET POWER CAPACITOR General Data * POWER FACTOR CORRECTION The power factor of a load is defined as the ratio of active power to apparent power, i.e. kw : kva and is referred

More information

Automatic capacitor banks with detuned filters

Automatic capacitor banks with detuned filters Power factor correction and harmonic filtering 5 R. /6 Automatic capacitor banks with detuned filters R. 5 /6 Automatic capacitor banks with detuned filters Introduction R5/6-3 R.5 - Automatic capacitor

More information

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262) SWF DV/DT Solutions Sinewave Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Does your application use variable frequency drives for improved

More information

ALPTEC POWER FACTOR CONTROLLER

ALPTEC POWER FACTOR CONTROLLER ALPTEC POWER FACTOR CONTROLLER ALPTEC3 ALPTEC5 ALPTEC7 ALPTEC12 0 REF : 2008-ALPTEC3.5.7.12-01-ANG CONTENTS I GENERAL INFORMATION. 2 II WAYS TO SET UP THE CONTROLLER.. 4 III OPERATING MODE..6 IV ADVANCED

More information

Automatic capacitor banks with detuned filters

Automatic capacitor banks with detuned filters الکتروه م ند Power factor correction and harmonic filtering Automatic capacitor banks with detuned filters www.electrohamand.com Automatic capacitor banks with detuned filters Introduction R5/6-3 R.5 -

More information

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax : NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata - 700 032, Tel : 033 2477 3126; Fax : 033 2477 2403 www.ntplindia.com SPECIFICATION NTPL MAKE MICRO-CONTROLLER BASED AUTOMATIC 50KV/10A AC HIGH VOLTAGE

More information

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company P2 Power Solutions Pvt. Ltd. An ISO 9001:2008 Company Quality Power within your Reach P2 Power Magnetics P2 Power Solutions Pvt. Ltd. P2 Power Solutions Pvt. Ltd. provides EMC and power quality solutions,

More information

Introduction: TAS PowerTek Ltd. MAVROS

Introduction: TAS PowerTek Ltd. MAVROS Introduction: Electrical supply system in today s scenario faces a major challenge due to Power Quality issues. Harmonics on supply system due to Electronics type of loads that are used extensively. Power

More information

Thyristorised Automatic Power Factor

Thyristorised Automatic Power Factor Thyristorised Automatic Power Factor Correction with 7% D Tune Harmonics Suppression (Reactor/Filtering) System Power quality? In the present Low voltage (LV) industrial distribution system the power factor

More information

Power factor correction and harmonic filtering. Automatic power factor regulators R.1

Power factor correction and harmonic filtering. Automatic power factor regulators R.1 Power factor correction and harmonic filtering Automatic power factor regulators R.1 R.1 Automatic power factor regulators R.1 - Automatic power factor regulators Selection table R1-4 computer Plus-T Intelligent

More information

Low Pass Harmonic Filters

Low Pass Harmonic Filters Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power

More information

LV Compensation & Filtering Products

LV Compensation & Filtering Products GE Grid Solutions LV Compensation & Filtering Products Providing Power Quality and Energy Efficiency Low (LV) reactive power compensation and harmonic filtering solutions help customers to improve the

More information

Reactors for filtering

Reactors for filtering NEW ZEALAND WWW.LPINZ.CO.NZ Unit 6/22 Moselle Ave, Henderson, Auckland, New Zealand PO Box 21-872, Henderson, Auckland, New Zealand Phone:+64 9 833 5749 Email:info@LPINZ.co.nz Web: www.lpinz.co.nz Reactors

More information

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. This document may be subject to changes. Contact ARTECHE to confirm the characteristics and availability of the products

More information

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Installation and Operating Instructions. Power IT Power Factor Controller RVC Installation and Operating Instructions Power IT Power Factor Controller RVC Table of contents Page 1. Read this first... 3 About this Instruction Manual... 3 Safety... 3 Electromagnetic compatibility...

More information

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12 INSTRUCTION MANUAL Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS Power Factor Controller A12 1. CONTENTS 1. CONTENTS 1 2. FEATURES 2 3. INSTALLATION, CONNECTION AND APPLYING POWER 2 4.

More information

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz POWER QUALITY INSTRUCTION MANUAL Type SWF Sine Wave Filters 690 Volts, 50Hz Page 2 of 24 Contents 1. Introduction & SAFETY 2. Theory of operation 3. Typical results of the Sine Wave Filters 4. Transportation,

More information

Computer-14d - xx - 144a

Computer-14d - xx - 144a POWER FACTOR REGULATOR Computer-14d - xx - 144a INSTRUCTION MANUAL ( M 981 602 / 98B ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 14d --------- Page 2 1.- POWER FACTOR REGULATORS COMPUTER-14d-144a

More information

Power Factor Controller BR 5306 / 5312

Power Factor Controller BR 5306 / 5312 Power Factor Controller BR 5306 / 5312 Instruction book 1.GENERAL The BR 53 is equipped with a single-chip micro- computer. This version, which has been additionally improved by a number of new design

More information

Onsite Mobile AC High Voltage Test System

Onsite Mobile AC High Voltage Test System TSGMF(T) series Onsite Mobile AC High Voltage Test System Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument

More information

Monitoring Electric Network Via Internet

Monitoring Electric Network Via Internet Monitoring Electric Network Via Internet NETWORK ANALYSER let "it" analyse! MPR63 Real time monitoring via internet / intranet Measurement of all electrical parameters Including Harmonics Automatic recording

More information

Power IT LV Active Filters PQFA - PQFL - PQFT

Power IT LV Active Filters PQFA - PQFL - PQFT Power IT LV Active Filters PQFA - PQFL - PQFT The ABB comprehensive solution for active filtering of harmonics Pst Harmonics and Power Quality Harmonics caused by non-linear electrical loads such as variable

More information

Stabilized Differential Relay SPAD 346. Product Guide

Stabilized Differential Relay SPAD 346. Product Guide Issued: July 1998 Status: Updated Version: D/21.03.2006 Data subject to change without notice Features Integrated three-phase differential relay, three-phase overcurrent relay and multiconfigurable earth-fault

More information

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description: OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description: VTOP 2(1) X Dry Insulated voltage transformer (VT) There are two designs of this voltage transformers: - VTOP 1-X single phase, dry insulated

More information

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications: SGMF(T) series Onsite Mobile AC High Voltage Test System On-site AC high voltage test systems are used for voltage withstanding test, partial discharge measurement, tan delta measurement on those instrument

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

PFCC-1000 series. Powerful Flexibility Durability - Quality. Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter

PFCC-1000 series. Powerful Flexibility Durability - Quality. Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter PFCC-1000 series Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter Powerful Flexibility Durability - Quality email.us.at:.quotes@tanddproducts.com www.tanddproducts.com

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

Power Processor - Series 700F 10KVA to 150KVA

Power Processor - Series 700F 10KVA to 150KVA Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines

More information

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers KNOW MORE ABOUT THE TRANSFORMERS Glossary Transformers Ambient temperature The existing temperature of the atmosphere surrounding a transformer installation. Ampere The practical unit of electric current.

More information

Reactive Energy Management

Reactive Energy Management Power Factor Correction Reactive Energy Management Low Voltage components Catalogue 2013 Reactive Energy management Your requirements. Optimize energy consumption By reducing electricity bills, By reducing

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information

AMIK 200 / 201 Technical Data Sheet

AMIK 200 / 201 Technical Data Sheet AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT

More information

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and

More information

DEIF A/S. Insulation monitor. Type SIM-Q

DEIF A/S. Insulation monitor. Type SIM-Q Insulation monitor 4921232C Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range 1...Mohm or 1...Mohm Alarm on

More information

DETUNED INDUCTORS FOR PF IMPROVEMENT CAPACITORS

DETUNED INDUCTORS FOR PF IMPROVEMENT CAPACITORS DETUNED INDUCTORS FOR PF IMPROVEMENT CAPACITORS Electrical supply systems harmonics is like a cancer on supply systems and causes extreme bad effects on the supply system component and connected electrical

More information

PFC POWER FACTOR CONTROLLERS POWER NEEDS CONTROL

PFC POWER FACTOR CONTROLLERS POWER NEEDS CONTROL PFC POWER FCTOR CONTROLLERS POWER NEEDS CONTROL 1 PFC power factor controllers utomatic power factor correction controller series PFC 6, 8, 12 RS DESCRIPTION n essential way of electrical energy cost reduction

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

SHARDA Make Harmonics Filter

SHARDA Make Harmonics Filter SHARDA Make Harmonics Filter SHARDA offers perfect solution to minimize Harmonics level of industries where non-linear load like, VFD, Electronics load, Convertors, Voltage booster equipment s are present.

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION Single-Phase Low Voltage Dry- Type Transformers 5-400 kva Three-Phase Low Voltage Dry- Type Transformers 7.5-1000 kva TECHNICAL INFORMATION TABLE OF CONTENTS Introduction...3 Technical Explanations...4

More information

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

Varplus 2 capacitors installation guide

Varplus 2 capacitors installation guide 2006 Varplus 2 capacitors installation guide Contents Reactive power Power definition 3 Electrical network pollution Choice of compensation type 4 Choice of detuned reactor tuning frequency 6 Control and

More information

VARIABLE FREQUENCY RESONANT TEST SYSTEM

VARIABLE FREQUENCY RESONANT TEST SYSTEM VARIABLE FREQUENCY RESONANT TEST SYSTEM 400kV,1200kVA Tank Type Reactor for Outdoor Cable Test Field 650kV, 5850kVA, Cylinder Type Reactors for Onsite Testing of GIS and Cable PHENIX Variable Frequency

More information

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation Portable Description Features Measures all of the main electrical parameters of an electricity network Measurement in true root mean square Built-in energy meter With 4 voltage channels and 4 current channels

More information

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact

More information

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

Advantages There are many diverse advantages of a portable analyzer for the user. The most important is information.

Advantages There are many diverse advantages of a portable analyzer for the user. The most important is information. Portable s CIRCUTOR offers a wide range of portable analyzers designed to measure, display and/or record the most important parameters of an electrical network. With the analysis of the electrical parameters,

More information

Protection relays and transformers

Protection relays and transformers NEW ZEALAND WWW.LPINZ.CO.NZ Unit 6/22 Moselle Ave, Henderson, Auckland, New Zealand PO Box 21-872, Henderson, Auckland, New Zealand Phone:+64 9 833 5749 Email:info@LPINZ.co.nz Web: www.lpinz.co.nz Protection

More information

ESTAmat MH Mounting Instructions MV1151

ESTAmat MH Mounting Instructions MV1151 ESTAmat MH Mounting Instructions MV1151 VISHAY ELECTRONIC GMBH - Geschäftsbereich ROEDERSTEIN, ESTA und Hybride Hofmark-Aich-Str. 36 - Phone (49)-871/86-0 - Fax (49)-871/86 25 12 - D-84030 Landshut - Germany

More information

1 INTRODUCTION ORDER CODE / INFORMATION

1 INTRODUCTION ORDER CODE / INFORMATION INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

K Factor Power Transformers

K Factor Power Transformers Ashley-Edison AsiaElectricTransformers (UK) K Factor Power Transformers DTKF series Low Voltage Dry Type K Factor Power Transformers AET-DTKF-2004-01: Page 1 Asia Electric Transformers, Entrepreneur Business

More information

Series P. Applications

Series P. Applications Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any

More information

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers EPCOS Product Brief 2017 Power Quality Solutions of Active Harmonic Filters and Power Optimizers EPCOS has been offering a comprehensive range of key components for power factor correction (PFC) and power

More information

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS High voltage shunt capacitor banks Alstom Grid high voltage shunt capacitor bank offering is divided in: By bank construction HV open rack capacitor banks HV enclosed capacitor banks By bank design HV

More information

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX SSE-N NEGATIVE FIELD FORCING SHUNT STATIC EXCITER/REGULATOR SYSTEM Control Chassis 6 SCR Power Chassis APPLICATION The SSE-N Negative Field Forcing Exciter/Regulator is used for both new and old installations

More information

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers Secondary Injection Relay Test Set Designed for testing relays and transducers Microprocessor controlled With phase angle shifter Frequency generator Test results and settings are saved into local memory

More information

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA PERFORMANCES High accuracy High stability Fast transients High inrush current facilities Wide bandwidth 25 khz at -3dB Internal waveform DC and up to 10 khz Very low distortion Quadrant change without

More information

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO PART - A : SPECIFIC REQUIREMENTS THIS DATA SHEET IS APPLICABLE FOR IN BOILER A CLIMATIC CONDITIONS PACKAGE 1 DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.71 MTRS. 3 RELATIVE HUMIDITY 74 %

More information

Reactive Power Control Relay RM 2106 / 2112 Operating Instructions. FRAKO Kondensatoren- und Anlagenbau

Reactive Power Control Relay RM 2106 / 2112 Operating Instructions. FRAKO Kondensatoren- und Anlagenbau Reactive Power Control Relay RM 2106 / 2112 Operating Instructions FRAKO Kondensatoren- und Anlagenbau www.frako.com Figure 1 Front view a b c d e Display for active capacitor stages Display for inductive

More information

T 1000 PLUS Secondary Injection Relay Test Set

T 1000 PLUS Secondary Injection Relay Test Set Secondary Injection Relay Test Set Designed for testing relays and transducers Microprocessor controlled With phase angle shifter Frequency generator Test results and settings are saved into local memory

More information

Challenges of Parallel Operations

Challenges of Parallel Operations GENLINK TM issimilar Pitch Limiter Key Features Inserts >40% impedance in neutral current circulating path Reduces neutral circulating current by >75% Adds

More information

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers Secondary Injection Relay Test Set Designed for testing relays and transducers Two current outputs to test differential relays Convertible current and voltage generator With phase angle shifter Frequency

More information

SPAD 346 C Stabilized differential relay

SPAD 346 C Stabilized differential relay SPAD 346 C Stabilized differential relay Stabilized Differential Relay Type SPAD 346 C Features Integrated three-phase differential relay, three-phase overcurrent relay and multiconfigurable earth-fault

More information

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers Secondary Injection Relay Test Set Designed for testing relays and transducers Microprocessor controlled With phase angle shifter Frequency generator High power outputs Large graphical display Compact

More information

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock

More information

VI 3 - i TABLE OF CONTENTS

VI 3 - i TABLE OF CONTENTS VI 3 - i TABLE OF CONTENTS 3 PROJECT SPECIFIC DATA... 1 3.1 DEFINITIONS... 1 3.1.1 Design Data, High and Medium Voltage... 1 3.1.2 Design Data, Low Voltage Equipment... 2 3.1.3 Phase Relationship... 3

More information

Zelio Control Measurement Relays

Zelio Control Measurement Relays Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and

More information

AC Resonant Test Systems Tank Type Up to 150 kv

AC Resonant Test Systems Tank Type Up to 150 kv R AC Resonant Test Systems Tank Type Up to 150 kv PHENIX TECHNOLOGIES Testing Applications AC Resonant Test Systems are used where the load is largely capacitive with very low real power losses such as

More information

ATK Clamp Meter

ATK Clamp Meter ATK-2209 Clamp Meter User s Manual Title CONTENTS Page I. SAFETY INFORMATION... 1 II. TECHNICAL SPECIFICATIONS... 2 2-1 Environment Conditions... 2 2-2 Maintenance... 2 2-3 Features... 2 2-4 General Specifications...

More information

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6 Index Index Page Capacitor Switching - 2 Contactors Typical Circuit Diagram 2 Auxiliary Contact Blocks 2 Contactors 3 Dimensions 3 Technical Data 4,5,6 Contactor operation 7 Function 8 Construction 9 Oscillogram

More information

Technical Data Sheet AMIK 300 / 301

Technical Data Sheet AMIK 300 / 301 USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important

More information

Real Time Power Factor Correction Units (Transient Free Switching)

Real Time Power Factor Correction Units (Transient Free Switching) Real Time Power Factor Correction Units (Transient Free Switching) Designers and Manufacturers of Power Factor Correction Equipment and Harmonic Filters 1016 34 AV SE Calgary, AB T2G 1V4 Canada Tel: 403

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

Commissioning and Maintenance of Power Factor Correction Systems

Commissioning and Maintenance of Power Factor Correction Systems Dear Customer, We would like to thank you for choosing a power factor correction system from FRAKO Kondensatoren- und Anlagenbau GmbH. It is a pleasure to welcome you into the ever-expanding circle of

More information

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN Energy Management Energy Analyzer Type EM11 DIN Other versions available (not certified, option X): see how to order on the next page Product Description Class 1 (kwh) according to EN62053-21 Class B (kwh)

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

HARMONICS CAUSES AND EFFECTS

HARMONICS CAUSES AND EFFECTS HARMONICS CAUSES AND EFFECTS What is Harmonics? Harmonics is defined as the content of the signal whose frequency is an integral multiple of the system frequency of the fundamentals. Harmonics current

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

79/26 Series III Multimeter

79/26 Series III Multimeter 79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position

More information

MODEL: M2DYS SEN TRONIC AG

MODEL: M2DYS SEN TRONIC AG Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical

More information

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices BETA Measuring /2 Product overview /3 7KT1 14, 7KT1 53 E-counters /9 7KT1 11, 7KT1 digital measuring devices /11 7KT1 0 analog measuring devices / 7KT5 8 time and pulse counters /14 7KT5 5, 7KT5 6 time

More information

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS Application: The Jewell DPM Power 96x96 series measures system active Power (Import/Export), Reactive Power (Import/Export), Apparent Power & Power Factor of Three Phase and Single Phase Network. It has

More information

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Energy Meter Type EM21 72R Retro-Fit Energy Management Energy Meter Type EM21 72R Retro-Fit Including 3 miniature split-core current sensors 10mm (90A), 16mm (150A) and 24mm (250A) diameter holes Class A (kwh) according to EN50470-3 Class

More information

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF / LF Insulation monitor Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range...kω or 1...MΩ Working frequency down

More information

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900 Coil Products Coil Products Customer partnership around the globe More than 250,000 coil products delivered to more than 170 countries. More than 60 years of operational experience. 35,000 in Europe 13,000

More information

CAPACITORS. Capacitors for AC and DC General Purpose Applications. Proven EIA-456-A Compliant 60,000 Hour Reliability Industry Standard

CAPACITORS. Capacitors for AC and DC General Purpose Applications. Proven EIA-456-A Compliant 60,000 Hour Reliability Industry Standard CAPACITORS Capacitors for AC and DC General Purpose Applications Proven EIA-456-A Compliant 60,000 Hour Reliability Industry Standard To ensure correct selection of a capacitor for your application, please

More information

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features CT ratio Power Harmonics ac+dc 200ADM-P Current Injection System with Phase Shift Features 0-200A output current True RMS metering with 1 cycle capture Variable auxiliary AC voltage/current output with

More information

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES PERFORMANCES High accuracy High stability Fast transients High inrush current facilities Wide bandwidth Very low distortion Quadrant change without transition Very low output impedance Low noise RS232

More information

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor

More information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY

More information

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd. Functional Range - Earth Fault Relay C&S Protection & Control Ltd. 2 Contents Page No. 1. Application 2. Operating Principle. Current Transformer Connections 5. Connections, Contact Arrangement and Setting

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information