8-channel digital input module; 24 VDC; 3.0 ms; high-side switching; 1-conductor connection

Size: px
Start display at page:

Download "8-channel digital input module; 24 VDC; 3.0 ms; high-side switching; 1-conductor connection"

Transcription

1 Printview: 8-channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection - Item No: channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection Item No: channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection Marking Business data Supplier WAGO Item no EAN Content Order amount Customer item number Notes The digital input module provides 8 channels at a width of just 2mm (047in) It receives control signals from the digital field devices (sensors, etc)each input module has a noise-rejection filter This filter is available with different time constantsfield and system levels are electrically isolated Technical data Miscellaneous Color light gray Conformity marking CE Number of inputs 8 Isolation 00 V system/supply Voltage via power jumper contacts 24 V DC (-2 % +30 %) Current via power jumper contacts (max) [A] 0 [A] Current consumption (internal) [ma] 7 [ma]

2 Printview: 8-channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection - Item No: Technical data Signal voltage (0) Signal voltage () Input filter Input current (typ) Internal bit width -3 V + V DC V 30 V DC 30 ms 28 ma 8 bits Degree of pollution II; acc to IEC 63-2 Voltage drop at I max [V] Degree of protection Data contacts Power jumper contacts < [V] IP20 Gleitkontakte, hartvergoldet,,µm, selbstreinigend Messer-/Federkontakt, selbstreinigend Clearances and creepage distances gem IEC Connection technology () Cross section from () [mm²] Cross section up to () [mm²] Cross section from () [AWG] Cross section up to () [AWG] Stripped length from () [mm] Stripped length up to () [mm] Stripped length () [in] Fire load [MJ] Weight [g] Width [mm] Width [in] Height [mm] Height [in] Length [mm] Length [in] CAGE CLAMP 008 [mm²] 2 [mm²] 28 [AWG] 4 [AWG] 8 [mm] 9 [mm] 033 [in] 089 [MJ] [g] 2 [mm] 0472 [in] 64 [mm] 22 [in] 00 [mm] 3937 [in] Storage temperature -2 C +8 C Relative air humidity (no condensation) [%] 9 [%] Type of mounting Operating temperature Mounting position DIN 3 rail 0 C + C any Exposure to pollutants gem IEC und IEC EMC: marine applications - emission of interference acc to Germanischer Lloyd (2003) 2

3 Printview: 8-channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection - Item No: Technical data EMC: marine applications - immunity to interference acc to Germanischer Lloyd (2003) EMC: CE - emission of interference acc to EN (2007) EMC: CE - immunity to interference acc to EN (200) Housing material Polycarbonat, Polyamid 66 Maximum pollutant concentration with a relative humidity < 7 SO2 2 ppm; H2S 0 ppm Shock resistance acc to IEC Vibration resistance acc to IEC Approbation Item No Registration Registration no Voltage [V] Current [A] Cross section [mm², AWG] ABS 0-HN77034-X ABS 03-HG374860/3- PDA BSH Bescheinigung Nr BV 343/C0 BV DNV A GL HH IECEx IECEx PTB / KR HMB0880- AC LR 02/20026 (E4) NK TA276M Rina ELE3422XG UL 08 ATEX 428 X UL E799 Sec UL E98726 Sec Accessories 3

4 Printview: 8-channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection - Item No: Accessories Carrier rail Item no Description Pack unit (Sub Pack) 20-2 Steel carrier rail; 3 x 7 mm; mm thick; 2 m long; slotted; according to en 607; "Hole width 2 mm 20-3 Steel carrier rail; 3 x 7 mm; mm thick; 2 m long; unslotted; according to en Steel carrier rail; 3 x mm; mm thick; 2 m long; unslotted; according to en Steel carrier rail; 3 x 7 mm; mm thick; 2 m long; slotted; according to en 607; "Hole width 8 mm 20-8 Steel carrier rail; 3 x mm; 23 mm thick; 2 m long; unslotted; according to en Aluminum carrier rail; 3 x 82 mm; 6 mm thick; 2 m long; unslotted; according to en Steel carrier rail; 3 x mm; mm thick; 2 m long; slotted; according to en Copper carrier rail; 3 x mm; 23 mm thick; 2 m long; unslotted; according to en Steel carrier rail; 3 x 7 mm; mm thick; 2 m long; slotted; galvanized; according to EN Steel carrier rail; 3 x 7 mm; mm thick; 2 m long; unslotted; galvanized; according to EN Steel carrier rail; 3 x mm; mm thick; 2 m long; unslotted; galvanized; ähnlich EN Steel carrier rail; 3 x mm; mm thick; 2 m long; slotted; galvanized; ähnlich EN 607 4

5 Printview: 8-channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection - Item No: Accessories Marking accessories Item no Description Pack unit (Sub Pack) Mini-WSB Inline; plain;,700 Mini-WSB markers ( mm) on roll; stretchable - 2 mm Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers Markers for group marker carrier; DIN A4 sheet (60 markers) /73 Series marker carrier 0

6 Printview: 8-channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection - Item No: Accessories General accessory Item no Description Pack unit (Sub Pack) Operating tool with partially insulated shaft; Type, blade (2 x 04) mm; suitable for 279, 726, 727, 2000, 200 and 2020 series Operating tool with partially insulated shaft; Type 2, blade (3 x 0) mm; suitable for 260, 26, 262, 264, 270, 280, 28, 290, 77, 776, 777, 769, 780, 78, 869, 870, 880, 2002, 2003, 2004, 200 and 2022 Series Power supply unit; with universal mounting carrier; AC 230 V / DC 24 V,; Output voltage indication Power supply unit; with universal mounting carrier; AC V / DC 24 V,; Output voltage indication Shield clamping saddle; mm wide; diameter of compatible conductor; up to 8 mm Shield clamping saddle; 9 mm wide; diameter of compatible conductor; 7 mm to 6 mm Shield clamping saddle; 27 mm wide; diameter of compatible conductor; 6 mm to 24 mm Shield clamping saddle; 43 mm wide; diameter of compatible conductor; 22 mm to 40 mm 0 6

7 Printview: 8-channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection - Item No: Images & drawings 7

8 Printview: 8-channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection - Item No:

9 Printview: 8-channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection - Item No: Address Hansastr Minden Telefon: 07/887-0 Fax: 07/ Technische Änderungen und Irrtümer vorbehalten 9

Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No.:

Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No.: Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No: 70-4 4-channel analog input module; 4-20 ma; Single-ended Item No: 70-4 4-channel analog input module; 4-20 ma; Single-ended Marking

More information

Switching relay terminal block; Relay with 1 changeover contact (1u); with miniature switching relay

Switching relay terminal block; Relay with 1 changeover contact (1u); with miniature switching relay relay - Item No: 89-304 Switching relay terminal block; Relay with changeover contact (u); with miniature switching relay Item No: 89-304 Switching relay terminal block; Relay with changeover contact (u);

More information

POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 )

POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 ) POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 ) vibration-proof fast maintenance-free WAGO BENEFITS Using springs instead of screws is the key to WAGO s success.

More information

POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 )

POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 ) POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 ) vibration-proof fast maintenance-free WAGO BENEFITS Using springs instead of screws is the key to WAGO s success.

More information

08/07/2015

08/07/2015 17.5 mm - 1 Solid State Relay 0.7A MUS2 Part number 88827004 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external

More information

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany 522 WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany WAGO Products: WAGO-I/O-SYSTEM with ETHERNET Controllers, DALI and EnOcean Components Wireless Technologie System Overview 524

More information

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Datenblatt. W-Series WDU 10

Datenblatt. W-Series WDU 10 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Datenblatt. W-Series WDU 2.5

Datenblatt. W-Series WDU 2.5 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Operating tools. with partially insulated shaft Type 1, 2 and 3 in set

Operating tools. with partially insulated shaft Type 1, 2 and 3 in set Accessories 40 Accessories 41 Operating Tools 42 45 Operating Tools WINSTA 46 47 Disconnection Tools 48 Cable Strippers 500 Wire Strippers 501 Cable Cutters 502 Crimping Tools 502 503 Test and Measurement

More information

Temperature sensor with integrated transmitter for maritime applications, MBT 5560

Temperature sensor with integrated transmitter for maritime applications, MBT 5560 Temperature sensor with integrated transmitter for maritime applications, MBT 5560 Technical brochure Features Designed for use in harsh maritme environments where reliable, robust and accurate equipment

More information

08/07/2015

08/07/2015 17.5 mm - 1 Relay 8A MUR1 Part number 88827105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external load connection

More information

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC) 6ES7214-1AG31-0XB0 Page 1 Product data sheet 6ES7214-1AG31-0XB0 SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V

More information

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.: Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer

More information

Rudder or propeller angular position transmitter KINAX WT720

Rudder or propeller angular position transmitter KINAX WT720 Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to

More information

Switching power supplies CP range, Linear power supplies CP-L range. Content

Switching power supplies CP range, Linear power supplies CP-L range. Content CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional

More information

Temperature head transmitter itemp TC TMT 188

Temperature head transmitter itemp TC TMT 188 Technical information TI 077R/24/ae No.: 510 06145 Temperature head transmitter itemp TC TMT 188 Universal head transmitter for thermocouples for an economical, high accuracy temperature monitoring. Fixed

More information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471 > 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels

More information

Temperature transmitter itemp RTD DIN rail TMT 127

Temperature transmitter itemp RTD DIN rail TMT 127 Technical information TI 095R/24/ae Nr. 510 06165 Temperature transmitter itemp RTD DIN rail TMT 127 Pt100 transmitter for an economical, high accuracy temperature monitoring. Fixed range measurement,

More information

Relative pressure transmitter type 522 for shipbuilding

Relative pressure transmitter type 522 for shipbuilding Relative pressure transmitter type 522 for shipbuilding Pressure range 0... 2.5 1000 bar The compact type 522 pressure transmitter for shipbuilding is based upon the Huba Control developed thick film technology

More information

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC) Technical information itemp TC TMT128 DIN rail mounted Temperature Transmitter for Thermocouples (TC) Application Temperature transmitter with fixed measuring ranges for converting TC input signals into

More information

Data sheet. W-Series WDU 2.5

Data sheet. W-Series WDU 2.5 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.: Extract from the online catalog MCR-C-UI-UI-DCI Order No.: 2810913 MCR 3-way isolating amplifier, with configurable I/O, for the electrical isolation of analog signals, with GL approval, preconfigured.

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR3 Part number 88867103 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

20 General technical data XI/ON

20 General technical data XI/ON 20 General technical data XI/ON General technical information General technical data XI/ON Potential isolation Ambient temperature Operating temperature Storage temperature Relative humidity Noxious gas

More information

LVDT. Inductive Position Transducer. SL Series. Key-Features:

LVDT. Inductive Position Transducer. SL Series. Key-Features: LVDT Inductive Position Transducer SL Series Key-Features: Content: - Measurement ranges 10...600 mm - External, or cable electronics with cable break detection - Linearity up to ±0.10 % of full scale

More information

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog NOVOHALL Rotary Sensor non-contacting Series RSC2800 analog The RSC 2800 sensor utilizes a contactless magnetic measurement technology to determine the measured angle. Unlike conventional Hall sensors,

More information

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange) D3G46-AH- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court

More information

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description Voltage transducer for AC voltages TERFACE Data sheet 006_en_0 PHOENIX CONTACT 00-0- Description The MCR voltage transducer measures AC voltages in several signal ranges from 0... ±4 V AC to 0... ±30 V

More information

PHOENIX CONTACT

PHOENIX CONTACT Selective circuit breaker CLIPLINE Data sheet 100464_en_05 PHOENIX CONTACT 2009-11-17 1 Description The electronic circuit breaker, which has a design width of just 12.5 mm, selectively protects all 24

More information

Zelio Control Measurement Relays

Zelio Control Measurement Relays Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

02/11/2015

02/11/2015 Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine

More information

Feed-through terminal block - PT 10-TWIN

Feed-through terminal block - PT 10-TWIN Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

02/11/2015

02/11/2015 Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions

More information

The shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications.

The shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications. The shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications. Shield (Screen) Connecting System VOLUME 1 Shield (screen) connecting system

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions Isolators, Isolator / Power Supplies Operating Instructions EN Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized

More information

LVDT. Inductive Position Transducer. SL Series. Key-Features:

LVDT. Inductive Position Transducer. SL Series. Key-Features: HM-1803 LVDT Inductive Position Transducer SL Series Key-Features: Content: - Measurement ranges 10...600 mm - External, or cable electronics with cable break detection - Linearity up to ±0.10 % of full

More information

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models Standard Flat Inductive Proximity Sensors Front and side facing surface IP67 DC -wire and DC -wire models Ordering Information DC -wire Models Shape distance Model Output and operating status mm MD1 *1

More information

Through and Ground Conductor Terminal Blocks 290 Series

Through and Ground Conductor Terminal Blocks 290 Series 11 474 Through and Ground Conductor Terminal Blocks 290 Series 0.34-1. mm"f-st" 0.31-1 mm"s" 1 00 V/6 kv/3 2 1 AWG 22-16"f-st" AWG 22-18"s" I N 13. A Terminal block width mm / 0.197 in 0.34-1. mm"f-st"

More information

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW Characteristics soft starter for asynchronous motor - ATSU01-32 A - 200..480V - 7.5..15 KW Main Range of product Product or component type Product destination Product specific application Device short

More information

Type Nominal voltage (V) Code HSV V

Type Nominal voltage (V) Code HSV V Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works

More information

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW Characteristics soft starter for asynchronous motor - ATSU01-22 A - 200..480 V - 4..11 KW Price* : 195.00 GBP Main Range of product Product or component type Product destination Product specific application

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions Main catalogue SNK Series Terminal Blocks Accessories Marking Solutions 10 5.2 mm m 0.205 in spacing 53 2.09" 26.7 1.05" 3 4 5 6 7 8 9 10 Save space by connecting s up to 4 mm2 (CB certified) 12 AWG in

More information

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Modular versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input

More information

VR20 - Inductive sensor (LVDT) Measurement range from 25 to 600 mm

VR20 - Inductive sensor (LVDT) Measurement range from 25 to 600 mm VR20 - Inductive sensor (LVDT) Measurement range from 25 to 600 mm Technical data: Measurement range [mm] 0 25 0 50 00 80 0 100 0 150 0 200 0 300 0 600 Linearity 0,30% (0,20% Optional), 1,50% for a range

More information

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

Smart Power Relay E I...

Smart Power Relay E I... Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building

More information

Data sheet. W-Series WDU 4 BL

Data sheet. W-Series WDU 4 BL The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Data sheet. W-Series WDU 10

Data sheet. W-Series WDU 10 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

PHOENIX CONTACT

PHOENIX CONTACT Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode

More information

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50 Technical Information Nivotester 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50 Area of application The Nivotester is suitable as a 1-channel switch amplifier for the Soliwave

More information

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry

More information

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device

More information

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions DT1100 E xx xx (PS) Galvanic Isolators Operating Instructions Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized

More information

Data sheet... W-Series WDU 2.5

Data sheet... W-Series WDU 2.5 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Data sheet. W-Series WDU 2.5 RT

Data sheet. W-Series WDU 2.5 RT The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

Datasheet ACT20M Signal Isolation and Conversion NEW

Datasheet ACT20M Signal Isolation and Conversion NEW Datasheet ACT0M Signal solation and Conversion NEW High quality signal isolation and conversion in a slim wide housing format is now available with Weidmuller s ACT0M range. Features include worldwide

More information

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature

More information

Rotary Measurement Technology Incremental Encoders

Rotary Measurement Technology Incremental Encoders -20 to 60 C Temperature Shock/vibration resistant Short-circuit protection Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection

More information

onlinecomponents.com

onlinecomponents.com Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common

More information

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and

More information

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

PHOENIX CONTACT - 09/2009

PHOENIX CONTACT - 09/2009 Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits

More information

02/11/2015

02/11/2015 "Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue

More information

02/11/2015

02/11/2015 35 mm - 2 Relays 8A PL2R1 Part number 88867455 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

Totalizing Counters mini-i

Totalizing Counters mini-i mini-i Type 634/635 Type 634: Counter with high immunity against magnetic interfere Type 635: Counter with high shock stability Miniature size Low power consumption Electrical connections in standard grid

More information

Level sensing pressure transmitter type 711

Level sensing pressure transmitter type 711 Level sensing pressure transmitter type 711 Pressure range 0... 0.1-16 bar The level sensing pressure transmitters of type 711 with a relative pressure measuring cell have an adjusted and amplified sensor

More information

Signal converter for electromagnetic flowmeters

Signal converter for electromagnetic flowmeters Quick Start Signal converter for electromagnetic flowmeters Electronic revision: ER 3.0.xx The documentation is only complete when used in combination with the relevant documentation for the flow sensor.

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS Timers DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to

More information

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv When temperatures are to be measured using Pt100 resistance thermometers in high-voltage environments, standard temperature transmitters

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS CSM_H3DS_DS_E_2_1 DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock.

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

IXARC Incremental Encoder UCD-IPT M100-PRD. Interface Programmable Incremental. Configuration Tool UBIFAST Configuration Tool (Version 1.6.

IXARC Incremental Encoder UCD-IPT M100-PRD. Interface Programmable Incremental. Configuration Tool UBIFAST Configuration Tool (Version 1.6. IXARC Incremental Encoder UCD-IPT00-08192-M100-PRD Interface Interface Programmable Incremental Programming Functions PPR (1-16384), Output, Counting Direction Configuration Tool UBIFAST Configuration

More information

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-I-LP-NC 2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate, Fuel-Cell Measurements

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate, Fuel-Cell Measurements GETTING STARTED GUIDE NI 9206 16 AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate, Fuel-Cell Measurements This document explains how to connect to the NI 9206. Note Before

More information

Protection components

Protection components General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the

More information

Measuring current transformers of the W, W series

Measuring current transformers of the W, W series Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000

More information

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation

More information

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

Solid-state Twin Timer

Solid-state Twin Timer Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time

More information

No-wear isolation of potentials in terminal block design

No-wear isolation of potentials in terminal block design TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly

More information