Color WHI, 455, 530 WHI, 455, 530 WHI, 455, 530. Up to 2 meters (80 ) long C rated PVC jacket, foil shield with drain.
|
|
- Caroline Hamilton
- 5 years ago
- Views:
Transcription
1 MicroBrite BT Series Product Highlights Ultra thin profile for easy installation in tight spaces Highest flux density among all Ai backlights Large working area with uniform illumination Three sizes available: BT0000 BT0000 BT mm x 0mm 00mm x 00mm 200mm x 00mm General Specifications Part Color All Controls (A Max) 62 0 BT0000 WHI, 4, Electrical Specifications BT0000 WHI, 4, BT20000 WHI, 4, Normal Operating Temperature 0-60 C Weight (g) Standard Cable Information BT g (.92oz), BT g (6.88oz), BT g (.04oz) Up to 2 meters (80 ) long - 0 C rated PVC jacket, foil shield with drain. Photobiological Risk Factor IEC 6247 Exempt Applicable Wavelengths: 80 Group (Low-Risk) Applicable Wavelengths: 4, 30, 62 Compliance IP Rating Lumen Maintenance IP0 L70 = 0,000 hours Updated //207 DCN2272 Updated 6/28/207 DCN 242
2 MicroBrite BT Series Mechanical Specifications - BT (illumn. area) (illumn. area) DIMENSIONS ARE IN MILLIMETERS [INCHES] Optical Performance- BT0000 Intensity Distribution 80-00% 60-80% 40-60% 20-40% 0-20% 0-0% = 2.7 mm Optical measurement taken using BT0000-WHII3 Working Area Working Distance Area of Illuminance & Intensity Light Output 28 x 28 (mm) Irradiance (W/M²): Min 6.; Typ Illuminance (klux): Min 4. ; Typ 3 Updated //207 DCN 2272 Updated 6/28/207 DCN 242 2
3 Mechanical Specifications - BT0000 MicroBrite BT Series (illumn. area) (illumn. area) DIMENSIONS ARE IN MILLIMETERS [INCHES] Optical Performance- BT0000 Intensity Distribution 80-00% 60-80% 40-60% 20-40% 0-20% 0-0% = 2 mm Optical measurement taken using BT0000-WHII3 Working Area Working Distance Area of Illuminance & Intensity Light Output 76 X 76 (mm) Irradiance (W/M²): Min 28.3; Illuminance (klux): Min.0; Typ 60.0 Updated //207 DCN 2272 Updated 6/28/207 DCN 242 3
4 Mechanical Specifications - BT20000 MicroBrite BT Series (illum. area) (illumn. area) DIMENSIONS ARE IN MILLIMETERS [INCHES] Optical Performance- BT20000 Intensity Distribution = 2 mm 80-00% 60-80% 40-60% 20-40% 0-20% 0-0% Optical measurement taken using BT20000-WHIIC Working Area Working Distance Area of Illuminance & Intensity Light Output 78 X 76 (mm) Irradiance (W/M²): Min 2.2; Typ Illuminance (klux): Min 9.; Typ 70.0 Updated //207 DCN 2272 Updated 6/28/207 DCN 242 4
5 Part Number Key MicroBrite BT Series Model Model Extension Spectral Wavelength Connector/ Control Alternative Connector BT XXXXXX XXX XX XXX BT (blue) 30 (green) 62 (red) 80 (IR) WHI (white) C C IC I3 I3S M2 Ex: BT0000-WHIC BT IC Available with IC, I3, and I3S Stock Product: shipped next day None Build to Order: shipped in two weeks Connector Control Options C Connector For use with: DCS Series Controllers C Connector For use with: Pulsar 320 Strobe Controller. ICS 2 (IC) Continous in-line controller Powered with: 24V power supply ICS 3 (I3) Combination strobe/continous in-line controller Powered with: 24V power supply ICS 3S (I3S) Default-OFF strobe/continous in-line controller Powered with: 24V power supply Operation and Wiring Pin (M2) ICS (IC) ICS 2 Function Wire Color +24 VDC Brown VDC White Analog Control 3 GND Blue 4 GLO Black N/A Gray ICS 3 (I3 and I3S) ICS 3 (I3 and I3S) Pin (M2) Function PNP/Active High Trigger Wire Color +24 VDC Brown 2 Reserved White 3 GND Blue VDC Analog Control Black Gray Optional M2 Pinout 2 4 male -position 3 Updated //207 DCN 2272 Updated 6/28/207 DCN 242
6 MicroBrite BT Series Warranty Information Every Advanced illumination, Inc. (Ai) product is thoroughly inspected and tested before leaving the factory. Products are warranted to be free of defects in workmanship and materials for a period of two years from the original date of purchase. Should a defect develop during this period, please contact Ai Customer Service or your Ai distributor for a Return Merchandise Authorization (RMA), and return the complete product, freight prepaid, to Ai. If a defect is found, Ai will - at our discretion - repair or replace the product without charge. Ai claims no liability for any implied warranties, including merchantability and fitness for a specific purpose. Electromagnetic Compatibility This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) as stated in the product specifications. These requirements and limits are designed to provide reasonable protection against harmful interference only when the product is operated in its intended industrial electromagnetic environment. To minimize the potential for electromagnetic interference or unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Customer Service For information on existing orders, or to make an order adjustment, contact us Monday through Friday 8:00 am to :00 pm ET or send an to orders@advill.com. Company Information Advanced Illumination 440 State Garage Road, Rochester VT Phone: Fax: info@advancedillumination.com Web: advancedillumination.com 20 Advanced Illumination Inc. All rights reserved Updated //207 DCN 2272 Updated 6/28/207 DCN 242 6
USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter
USER MANUAL MODEL 2029 Parallel to Serial/ Serial to Parallel Interface Converter C E R T I F I E D An ISO-9001 Certified Company Part #07M2029-B, Rev. C Doc. #102011UB Revised 6/16/09 SALES OFFICE (301)
More informationLINEAR LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED
product introduction LX150 Series Series LINEAR LIGHT Direct Connect The plug n play design of the Direct-Connect Linear Light Series gives users tremendous flexibility without the concern for additional
More informationLXE300. Four Mounting Holes on Base. Compliant IEC. Warranty
LXE300 Direct Connect LINEAR LIGHT MULTI-DRIVE TM P R O D U C T D A T A S H E E T High Intensity LEDs Aluminum Housing T-slots for Connecting Lights (Female) Four Mounting Holes on Base (Male) Warranty
More informationLED Series Sealed High-Intensity Area Lights
Datasheet High-Power Lighting for use with Banner Vision Systems To view or download the latest technical information about this product, including specifications, dimensions, accessories, and wiring,
More informationLXE Mounting Holes on Base. Warranty. Compliant IEC. Brightest linear light yet, delivering up to 100,000 lux in OverDrive mode
LXE300 Direct Connect LINEAR L IGHT MULTI-DRIVE TM P R O D U C T D A T A S H E E T High Intensity LEDs Metal Housing Tslots for Connecting Lights (Female) 4 Mounting Holes on Base (Male) Warranty 10 YEAR
More informationRM75. Miniature Mini IP 50 RING LIGHT LOW-ANGLE MULTI-DRIVE TM PRODUCT HIGHLIGHTS 5-PIN M12. RoHS YEAR. smartvisionlights.com. Compliant CE.
RM75 Miniature Mini RING LIGHT LOW-ANGLE MULTI-DRIVE TM P R O D U C T D A T A S H E E T Cable Length: 15.2 cm (6 ) Four T-slots for Mounting Aluminum Housing Optional Camera Adapter High Intensity LEDs
More informationLM45 MULTI-DRIVE TM. Miniature Mini LINEAR L IGHT IP 65 PRODUCT HIGHLIGHTS. RoHS YEAR. smartvisionlights.com. Compliant CE. Warranty.
LM45 MULTI-DRIVE TM Miniature Mini LINEAR L IGHT P R O D U C T D A T A S H E E T High Intensity LEDs Cable Length: 15.2 cm (6 ) 5-Pin M12 Connector (Male) Aluminum Housing T-slot for Mounting Warranty
More informationUSER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 457B Seven Port Active Twinax Star Hub An ISO-9001 Certified Company Part #07M457B-C Doc. #069011UC Revised 4/22/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com
More informationflexible lighting technology
As a provider of lighting solutions for the Machine Vision Industry, we are passionate about exceeding our customers expectations. As such, our ISO 9001 quality procedures are at the core of everything
More information3/4 turn pot Intensity control of 10% to 100% Clockwise increases intensity Analog Intensity
ODL300 Series LINEAR LIGHT Connect-a-light product introduction The ODL300 array utilizes 12 high intensity LEDs being the longest light in the Connect-a-light Series. It also features an integrated Overdrive
More informationUSER MANUAL. MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters An ISO-9001 CertiÞed Company Part# 07M3PMF9 Rev. C Doc# 056020U Revised 1/23/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationRMX75. Miniature Mini IP 65 RING LIGHT MULTI-DRIVE TM PRODUCT HIGHLIGHTS 5-PIN M12. RoHS YEAR. smartvisionlights.com. Warranty.
RMX75 Miniature Mini RING LIGHT MULTI-DRIVE TM P R O D U C T D A T A S H E E T Four T-slots for Mounting Silicone Lens Aluminum Housing Cable Length: 15.2 cm (6 ) Optional Camera Adapter High Intensity
More informationRM75 MINITURE MINI RING L IGHT IP 50 PRODUCT HIGHTLIGHTS 5 PIN M12. RoHS YEAR. smartvisionlights.com. Compliant CE. Compliant IEC. Rated.
RM75 MINITURE MINI RING L IGHT P R O D U C T D A T A S H E E T Cable Length: 6 4 T-slots for Mounting Optional Camera Adapter High Intensity LEDs 5Pin M12 Connector Warranty 10 YEAR Compliant IEC 62471
More informationM12 P R O D U C T H I G H T L I G H T S
RM75 MINIATURE MINI RING L IGHT P R O D U C T D A T A S H E E T Cable Length: 6 4 T-slots for Mounting Optional Camera Adapter High Intensity LEDs 5Pin M12 Connector Warranty 10 YEAR Compliant IEC 62471
More informationUSER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 3042 (CTS TDM-V.24) Time Division Multiplexor, RS-232 Part #: 07M3042-A Doc #: 119001UA Revised 3/26/01 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION
More informationACT-IR220Li/220LN IrDA Serial Port Adapter
ACT-IR220Li/220LN IrDA Serial Port Adapter Product Specification Summary ACTiSYS Corp. 48511 Warm Springs Blvd, Suite 206 Fremont, CA 94539, USA TEL: (510) 490-8024, FAX: (510) 623-7268 E-Mail: irda-support@actisys.com
More informationWLS28-2 UV LED Strip Light
WLS8- UV LED Strip Light Datasheet Banner's WLS8- UV LED Strip Lights have sturdy aluminum housings, shatterproof windows, and impressive environmental ratings, making them a cost-effective operator inspection
More informationACT-IR220L/LE IrDA Serial Port Adapter
ACT-IR220L/LE IrDA Serial Port Adapter Product Specification Summary ACTiSYS Corp. 48511 Warm Springs Blvd, Suite 206 Fremont, CA 94539, USA TEL: (510) 490-8024, FAX: (510) 623-7268 E-Mail: irda-support@actisys.com
More informationPRODUCT DATA SHEET. Quality control in food, chemicals, and textile industry Compatible with DDC-3 and ILD L Dimmers
Using Metaphase s proprietary optics, the works like a traditional line light but can project its light at a lower divergence angle. This helps keep a tight, structured beam of light at longer working
More informationUSER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 2017A RS-232 to 20ma Current Loop Converter Part# 07M2017A-A Doc# 073021UA Revised 10/15/93 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY
More informationLOTUS TM. LED Linelight. Key Features. Key Applications. Compact, Robust, Uniform LED Line Light
LOTUS TM LED Linelight Compact, Robust, Uniform LED Line Light LOTUS is a compact, robust LED line Light with integrated intensity control designed specifically for machine vision applications. It utilizes
More informationUX-CLL (UG-CLL, UC-CLL)
Using Metaphase s proprietary optics, the UX-Collimated works like a traditional line light but can project its light at a lower divergence angle. This helps keep a tight, structured beam of light at longer
More informationAMP-13 OPERATOR S MANUAL
AMP-13 OPERATOR S MANUAL Version 2.0 Copyright 2008 by Vatell Corporation Vatell Corporation P.O. Box 66 Christiansburg, VA 24068 Phone: (540) 961-3576 Fax: (540) 953-3010 WARNING: Read instructions carefully
More informationLTX-5520 Electrical / Optical Converter Operating Instructions
LTX-5520 Electrical / Optical Converter Operating Instructions Terahertz Technologies Inc. 169 Clear Road, Oriskany, NY 13424 (315) 736-3642 FAX (315) 736-4078 E-mail sales@terahertztechnologies.com Quick
More informationPRODUCT DATA SHEET FEATURES
The MetaBright Series is a high performance and uniform light source for silhouetting and transmissive applications. Using a full array LED layout, we can pack more LEDs per square inch to provide greater
More informationPSW-002. Fiber Optic Polarization Switch. User Guide
PSW-002 Fiber Optic Polarization Switch User Guide Version: 1.0 Date: May 30, 2014 General Photonics, Incorporated is located in Chino California. For more information visit the company's website at: www.generalphotonics.com
More informationAIS 300 Installation Instructions
Use these instructions to install the Garmin AIS 300 Automatic Identification System (AIS) Class B receiver device. Compare the contents of this package with the packing list on the box. If any pieces
More informationDIGITAL SOUND LEVEL DSM8930 METER USER S MANUAL. Please read this manual carefully and thoroughly before using this product.
DIGITAL SOUND LEVEL METER USER S MANUAL DSM8930 Please read this manual carefully and thoroughly before using this product. TABLE OF CONTENTS Introduction.............................. 2 3 Key Features................................
More informationDawson DSM150. Digital Light Meter User s Manual
Dawson DSM150 Digital Light Meter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of Box... Error! Bookmark not defined. Accessories... 4 Safety Information... 6 Certification...
More informationAmerican Power Design, Inc.
FEATURES 4 Customer Selects Output Voltage 4 Outputs to 1000 Vdc 4 Low Profile 4 Single and Dual Outputs 4 Ultra Wide Input Ranges (9-36Vdc, 20-60Vdc, 36-72Vdc) 4 1000 Vdc Output Isolation 4 Continuous
More informationDIGICELL ANYNET NETWORK ACCESS MODULE
Comm Activity Network Status Service DigiCell Any NET Network Access Module Network Interface Network Service AMPS Cellemetry GSM SMS CDMA GPRS Ethernet 1xRTT RS-232 TCP/IP Input 1 Standard S3 off, S4
More informationFits Tiger 320 Series UNIVERSAL FREQ/COUNTER INPUT MODULE
Fits Tiger 320 Series UNIVERSAL /ER INPUT MODULE Sensor. Magnetic, Namur, Source, Sink. De-coupling. 0.02 Hz high pass filter. Signal Type., (mv) or digital logic. Input Connector. Freq. Input (CH) Up/Down
More informationTIA-952 Optical/Electrical Converter. Operating Instructions
TIA-952 Optical/Electrical Converter Operating Instructions Terahertz Technologies Inc.169 Clear Road Oriskany NY 13424 (315) 736-3642 FAX (315) 736-4078 E-mail sales@terahertztechnologies.com 2/2012 Contents
More information3M Power Clamp Wiremount Connectors
Instructions Scope: This document describes the termination instructions for 3M Power Clamp Wiremount Connectors Series 355 and 358. 3M Part Numbers 35505-6XX0-XXX XX 35805-6XX0-XXX XX Applicable Documents:
More informationGETTING STARTED GUIDE NI khz to 100 MHz, 50 Ω, AC Coupled RF Receiver Module
GETTING STARTED GUIDE NI 9770 30 khz to 100 MHz, 50 Ω, AC Coupled RF Receiver Module This document explains how to connect to the NI 9770. Note Before you begin, complete the software and hardware installation
More informationPRODUCT DATA SHEET FEATURES
These special illuminators provide intense, evenly diffused illumination. The Diffused Dome Light is ideal for inspection of reflective, specular, rough or topographic surfaces. Optical grade reflector
More informationLPU-2127 User Manual
LPU-2127 User Manual Doc #9004169 Rev A1, 04/15 Table of Contents Introduction... iii Warranty and Warranty Restrictions... iv Chapter 1: Specifications and Options... 1 Dimensions...1 Specifications...
More informationGETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous
GETTING STARTED GUIDE NI 9239 4 AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous This document explains how to connect to the NI 9239. Note Before you begin, complete the software and hardware installation procedures
More informationADVANCED MICRO CONTROLS INC. Manual #: 940-0D043
ADVANCED MICRO CONTROLS INC. Manual #: 940-0D043 User Manual GENERAL INFORMATION Important User Information The products and application data described in this manual are useful in a wide variety of different
More informationAmerican Power Design, Inc.
FEATURES 4 Customer Selects Output Voltage 4 Outputs to 1000 Vdc 4 Fully Programable Outputs 4 Single and Dual Outputs 4 Wide Input Ranges (10-20Vdc, 18-36Vdc) 4 1000 Vdc Output Isolation 4 Continuous
More informationGETTING STARTED GUIDE NI AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling
GETTING STARTED GUIDE NI 9234 4 AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling This document explains how to connect to the NI 9234. Note Before you begin, complete the software
More informationCollimated Backlights BL-CL
The Collimated Backlight Series is a high performance, uniform, and collimated light source for high precision silhouetting and transmissive applications. Using precision optics, these lights are collimated
More informationAmerican Power Design, Inc.
FEATURES 4 Customer Selects Output Voltage 4 Fully Regulated Outputs to + or - 8000 Vdc 4 0-100% Programable Output 4 High Stability (
More informationl Time-of-Flight (ToF) is a highly accurate distance mapping and 3D imaging technology
Simblee RFD77402 IoT 3D ToF Sensor Module Simblee IoT 3D ToF Sensor Module RFD77402 DATASHEET Features l Fully Integrated microelectronic device with an embedded sensor and VCSEL(Vertical Cavity Surface
More informationSME/SMD Series. Infrared Components Ceramic Discrete Surface Mount Emitters and Detectors. Honeywell Sensing and Control
Emitters and Detectors FEATURES Small package size Glass lensed optics for efficient optical coupling Upright or inverted mounting capability Low profile, small size for flexible layout of multiple channels
More information15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS
15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS The SPD-315-D(S) PWM controller allows you to control the speed of a motor, brightness of a lamp or other load using a
More informationLL-105-R LED Dimmer & 0-10V Bridge Setup Guide
www.i2systems.com i2systems is a registered trademark of Integrated Illumination Systems, Inc. LightLink is a trademark of Integrated Illumination Systems, Inc. 2018 Integrated Illumination Systems, Inc.
More informationWLS28-2 Dual Color LED Strip Light
WLS8- Dual Color LED Strip Light Datasheet Banner s LED Strip Lights have sturdy aluminum housings, shatterproof windows, and impressive environmental ratings, making them an ideal general-purpose LED
More informationGETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous
GETTING STARTED GUIDE NI 9228 8 AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous This document explains how to connect to the NI 9228. Note Before you begin, complete the software and hardware installation procedures
More informationPRODUCT DATA SHEET. Quality control in food, chemicals, and textile industry Intensity Control
The MetaBright TM is another product in the Metaphase family of LED lights for line scan. Its narrow, structured beam delivers high intensity and concentrated light for a narrow field of view. The high
More information125 Mbps, 650 nm LED. Dimensions
DESCRIPTION The is a 125 Mbps LED designed to meet data transmission requirements in factory or office automation. The 650 nm wavelength provides operation in the low attenuation area of POF (Plastic Optical
More informationLE18, LE20, LE25 Incremental Linear Encoders
and LE30 LE18, LE20, LE25 Incremental Linear Encoders Motion Type: Linear Usage Grade: Industrial Output: Incremental Max Resolution: 0.1 to 10 m High Resolution - Industrial Ruggedness The Models LE18,
More informationModel RTX-12 Radio Modem
Model RTX-12 Radio Modem Grants Pass, Oregon 154 Hillview Drive Grants Pass, Oregon 97527 (541) 474-6700 Fax: (541) 474-6703 Both the RTX-12A and the RTX-12OEM are normally supplied with full transmit
More informationAUTOMATION. Operator s Manual. IRU-2xx4/3xx4 Series. Rev. A2, 11/08 Doc
AUTOMATION P R O D U C T S G R O U P, I N C. Operator s Manual IRU-2xx4/3xx4 Series Rev. A2, 11/08 Doc. 9002673 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com IRU-2xx4/3xx4
More informationInstruction Manual Model Upconverter
Instruction Manual Model 2006-01 Upconverter October 2013, Rev. B IF IN RF OUT Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or
More informationModel Digital Light Meter
User's Manual Model 401025 Digital Light Meter INTRODUCTION Congratulations on your purchase of Extech s Digital Light Meter. This professional meter, with proper care, will provide years of safe reliable
More informationMetaBright Diffused Tube Lights MB-DT
These special illuminators provide intense, evenly diffused illumination. The Diffused Tube light is ideal for inspection of reflective, specular, rough or topographic surfaces. Optical grade reflector
More informationSCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD
Modular Wireless I/O System User Manual Version V. for BENTEK SYSTEMS LTD #, 0 Ave S.E. Calgary, AB, Canada TB 0L Ph:(0) Fax:(0) email: sales@scadalink.com web: The is a Modular Wireless I/O System that
More informationPSI MIN MODULATOR BIAS CONTROLLER BOARD
PSI-211-44 MIN MODULATOR BIAS CONTROLLER BOARD USER GUIDE Rev A Photonic Systems, Inc. Tel: 978-67-499 9 Middlesex Turnpike Fax: 978-67-251 Building #5 www.photonicsinc.com Billerica, MA 1821 1 DOCUMENT
More informationAMP-12 OPERATOR S MANUAL
AMP-12 OPERATOR S MANUAL Version 1.0 Copyright 2002 by Vatell Corporation Vatell Corporation P.O. Box 66 Christiansburg, VA 24068 Phone: (540) 961-3576 Fax: (540) 953-3010 WARNING: Read instructions carefully
More informationUNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter
User Manual UNICOM 2500 Installation Operation Programming Universal Communication Converter UNICOM 2500 Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590 Tel 516.334.0870 Fax 516.338.4741
More informationAmerican Power Design, Inc.
, Inc. FEATURES 4 Customer Selects Output Voltage 4 Ultra Wide Input Ranges (936Vdc, 2060Vdc) 4 Efficiency 89% (typ.) 4 Independently Isolated Outputs 4 SixSided Shielded Case 4 Remote On/Off Control 4
More informationHigh Temperature InfraRed Thermometer with Laser Pointer
User s Manual High Temperature InfraRed Thermometer with Laser Pointer MODEL 42545 42545 Introduction Congratulations on your purchase of the Model 42545 IR Thermometer. The 42545 is capable of non-contact
More informationSafety light curtain to safeguard the hinge edge IMPORTANT NOTE
Installation and Operation Manual CEDES MicroRay Safety light curtain to safeguard the hinge edge English EN 12978 EN 13849-1 IMPORTANT NOTE FOLLOW THE INSTRUCTIONS GIVEN IN THIS MANUAL CAREFULLY. FAILURE
More informationTIA-2000 Optical/Electrical Converter. Operating Instructions
TIA-2000 Optical/Electrical Converter Operating Instructions Terahertz Technologies Inc. 169 Clear Road Oriskany NY 13424 Toll Free: (855) TTI-TEAM (876-8377) (315) 736-3642 FAX (315) 736-4078 E-mail sales@teratec.us
More informationNear Infrared Light Ring Series OPA80 and OPA83 Series
Features Designed for Near Infrared wavelength Cameras Daylight Light sensor available Variety of ring sizes Surface Mount or Through Hole s Product Photo Here Description: The OPA80 through OPA83 series
More informationDIN Thermocouple Conditioner MODEL 5M14(V)
5M14 1.A.0.5M14 DIN Thermocouple Conditioner MODEL 5M14(V) QUAD ISOLATED THERMOCOUPLE CONDITIONER Module 1 GENERAL DESCRIPTION AND SPECIFICATIONS The Model 5M14(V) is a precision conditioner designed for
More informationTIA-527 Balanced Optical/Electrical Converter. Operating Instructions
TIA-527 Balanced Optical/Electrical Converter Operating Instructions Terahertz Technologies Inc.169 Clear Road Oriskany NY 13424 (315) 736-3642 FAX (315) 736-4078 E-mail sales@terahertztechnologies.com
More informationTIA-3000 Optical/Electrical Converter. Operating Instructions
TIA-3000 Optical/Electrical Converter Operating Instructions Terahertz Technologies Inc.169 Clear Road Oriskany NY 13424 (315) 736-3642 FAX (315) 736-4078 E-mail sales@terahertztechnologies.com 6/2011
More informationTSSP-1 (Stainless Steel Thermistor Probe) Manual Rev A
TSSP-1 (Stainless Steel Thermistor Probe) Manual 57-6028 Rev A This page intentionally left blank. 2 2014 Dyacon, Inc Contents NOTICES...4 Copyright 2014 Dyacon, Inc...4 Manufacturer...4 Declarations...5
More informationSAS-543 Biconical Antenna Operation Manual
SAS-543 Biconical Antenna Operation Manual 1 TABLE OF CONTENTS INTRODUCTION Introduction...3 Intended Purposes...4 Optional Equipment...5 OPERATING INSTRUCTIONS Assembly Instructions...6 Mounting Instructions...6
More informationFLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual
SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS
More informationUser s Guide Instructions for Installation and Operation
User s Guide Instructions for Installation and Operation 2.4 GHZ SPREAD SPECTRUM REMOTE CONTROLS Keyfob Transmitters Models KTX24SS1 KTXW24SS3 KTX24SS2 KTX24SS3 Wall Mount Models NTX24SS1 NTX24SS2 Remote
More informationImage Experts for the Factory Floor
Image Experts for the Factory Floor At Advanced illumination (Ai), we understand just how difficult it can be to choose the correct light source in order to acquire the best image for your applications.
More information3M Mini D Ribbon (MDR) Cable Assembly.050 High Speed Digital Data Transmission System - 26 Position 14X26-SZLB-XXX-0LC
M Cable Assembly Supports Industrial CameraLink in Automated Imaging Association for camera to frame grabber communications 11 shielded twin-ax pairs and four drain wires Entire cable bundle is shielded
More informationProScale. Compact LCD Readout. Installation & Operation
ProScale Compact LCD Readout Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Measurement Systems against defective parts and workmanship for 1 year commencing from the
More informationProScale Compact LCD Readout. Operation. Firmware version C 2.xxx and higher
ProScale Compact LCD Readout Operation Firmware version C 2.xxx and higher WARRANTY Accurate Technology, Inc., warrants this product against defective parts and workmanship for 1 year commencing from the
More informationPIXEL. Features and Benefits.
Features and Benefits Seamless Dot-free Illumination High quality SMD LED Chip & IC Chip (Chasing) UV & flame resistant construction (PVC) Domed profile for large viewing angles (270 ) High illumination
More informationGPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.
GPNP Inc. NT384 NT1 User Manual Revision 1.00 17/6/2002 Information in this guide is subject to change without notification. Copyright 2002 GPNP Inc. U.S.A. IMPORTANT SAFETY INSTRUCTIONS When using your
More informationA-LAS Series A-LAS-F12. Design. A-LAS Series Analog Laser Light Barriers. Product name: Accessories: (cf. page 5) A-LAS-F12-(aperture)*-(fork size)**
A-LAS Series A-LAS-F12 - Analog signal (0...+10V) in connection with an electronic control unit type AGL3, AGL4, AGL4-HS, AGL-DIF, SI-CON11 (without PC connection) or SI-CON4, SI-CON8, SI-CON34, A-LAS-CON1
More informationINSTRUCTIONS MODELS AVX-TFR-MELF TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:
A V T E C H E L E C T R O S Y S T E M S L T D. N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P.O. BOX 265 OGDENSBURG, NY U.S.A. 13669-0265 TEL: 888-670-8729 (USA & Canada)
More informationAFFORDABLE ENERGY SOLUTIONS
2018 LAMPS LAMPS AFFORDABLE ENERGY SOLUTIONS Copyright 2017 RVLT - E Lighting, Inc. All Rights Reserved AFFORDABLE ENERGY SOLUTIONS TERMS & CONDITIONS 1. Terms All accounts subject to a late penalty of
More informationPKF series. General information. PKF series
PKF series PKF series General information SMD and through hole versions with ultra-low component height 8.0 mm (0.315 in.) Up to 87% efficiency at full load Safety requirements in accordance with EN60950
More informationInstallation/Operation Instructions and Warranty Information for Models...
Installation/Operation Instructions and Warranty Information for Models... D1300 D1300WDM D2300 D2300WDM D2300CP D1300 / D2300 / 2 - Wire Connection 4 3 2 1 No Connection No Connection - Data + Data D1300
More informationAdjustable beam angle LED bar DATASHEET EFFI-FLEX-CPT
Strobe version available Very intense and uniform illuminated area Full range of colors: from UV to IR, white, tricolor Long lifetime and few maintenance Standard connections and fasteners Flexible: Adjustable
More informationInstruction Manual MX-485-S Bi-directional RS485 Data Transceiver
Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver Copyright 2005, American Fibertek, Inc. 1020JD Table of Contents Functional Description...3 Installation...3 Power Source...3 Power Connection...3
More information3M Mini Serial Attached SCSI (minisas) Cable Assembly
M Mini Serial Attached SCSI (minisas) Cable Assembly 8N6 Series Gbps per channel data rate 6 Conductor signal assembly Multiple lengths available Metal latch designed to ensure retention Two levels of
More informationInstruction Manual Model Upconverter
Instruction Manual Model 2006-02 Upconverter October 2013, Rev. B IF IN RF OUT Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or
More informationDIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.
DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC. MODEL SELECTION GUIDE The DIN Series of Digital Panel Meters are rugged low cost meters for the measurement of dc voltage, dc current, Process voltage
More informationMetaBright Washdown Ring Light MB-RL205
The Metaphase offers high intensity, shadow-less illumination with five times the lifetime over fluorescents. Ring lights are essential for lighting specular or diffused surfaces. The MetaBright TM is
More informationUser's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32
User's Guide Wireless AC Circuit Identifier Models RT30 and RT32 Introduction Congratulations on your purchase of Extech s Model RT30 (914Mhz) or RT32 (869MHz) Wireless AC Circuit Identifier. The detector
More informationRFTX-1 Installation Manual
RFTX-1 Installation Manual complete control Universal Remote Control RFTX-1 Installation Manual 2009-2014 Universal Remote Control, Inc. The information in this Owner s Manual is copyright protected. No
More informationLX Series Part-Sensing Light Screen
Datasheet For Sensing Small or Flat Parts at High Speeds Emitter and receiver pair produce a strobed web of modulated light beams, in 8 lengths, 2 sensing ranges Simple, economical and highly reliable
More informationDawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual
Dawson DDM230C True RMS Multimeter with Bar Graph Display User s Manual Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Safety Information... 4
More information3M Shrunk Delta Ribbon (SDR) Cable Assembly.80 mm High Speed Digital Data Transmission, 26 position 1MG26-LFW0-00C-XXX
3M Shrunk Delta Ribbon (SDR) Cable Assembly.80 mm High Speed Digital Data Transmission, 26 position 1MG26-LFW0-00C-XXX Supports new AIA Industrial Camera Link Standard for new Mini C/L camera to C/L frame
More informationIR Receiver Modules for Remote Control Systems
IR Receiver Modules for Remote Control Systems FEATURES Very low supply current Photo detector and preamplifier in one package Internal filter for PCM frequency Improved shielding against EMI Supply voltage:
More informationAMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH
AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH INSTRUCTION MANUAL PLEASE READ THIS MANUAL BEFORE OPERATING THIS EQUIPMENT! 116 Willow Road Starkville, MS 39759 USA 662-323-8211 Version 3B Printed in U.S.A.
More informationGlobal Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, F: (979) 690-0440 Barometric Pressure: WE100 Solar Radiation: WE300
More informationTRIAXIAL FLUXGATE MAGNETOMETER OWNER'S MANUAL
TRIAXIAL FLUXGATE MAGNETOMETER OWNER'S MANUAL PART NUMBER: FGM-301 WATSON INDUSTRIES, INC. 3041 MELBY ROAD EAU CLAIRE, WI 54703 Phone: (715) 839-0628 FAX: (715) 839-8248 email: support@watson-gyro.com
More informationDYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est.
DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif. 95005 831-336-8891 Fax 831-336-3840 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual PIM-Universal-IO PMC IO Module PIM w/ SCSI II Bezel
More information