OPERATION MANUAL INSTALLATION AND KHS.1. 2-Channel High-Speed Data Module. Kilomux I/O Module. The Access Company

Size: px
Start display at page:

Download "OPERATION MANUAL INSTALLATION AND KHS.1. 2-Channel High-Speed Data Module. Kilomux I/O Module. The Access Company"

Transcription

1 INSTALLATION AND OPERATION MANUAL KHS.1 2-Channel High-Speed Data Module Kilomux I/O Module The Access Company

2

3 KHS.1 2-Channel High-Speed Data Module Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications. Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the KHS.1 and any software components contained therein are proprietary products of RAD protected under international copyright law and shall be and remain solely with RAD. KHS.1 is a registered trademark of RAD. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark. You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the KHS.1. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the KHS.1, based on or derived in any way from the KHS.1. Your undertaking in this paragraph shall survive the termination of this Agreement. This Agreement is effective upon your opening of the KHS.1 package and shall continue until terminated. RAD may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RAD, you agree to return to RAD the KHS.1 and all copies and portions thereof. For further information contact RAD at the address below or contact your local distributor. International Headquarters RAD Data Communications Ltd. 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel: Fax: , market@rad.com North America Headquarters RAD Data Communications Inc. 900 Corporate Drive Mahwah, NJ 07430, USA Tel: (201) , Toll free: Fax: (201) market@radusa.com RAD Data Communications Ltd. Publication No /08

4

5 Contents Chapter 1. Introduction 1.1 Functional Description Technical Specifications Chapter 2. Installation and Operation 2.1 General Installation Rear Panel Internal Settings Channel Interface Selection Changer Board Setting Procedure Module Installation Cable Connections Configuration Introduction Configuration Instructions Inclusion of KHS.1 Module in Database Selection of Main Link and Priority (Kilomux-2000/2100 only) Channel Configuration Channel Parameters Considerations in the Selection of the CTS and RTS_CTS_DEL Parameters Chapter 3. Alarms and Diagnostics 3.1 General Alarm Messages Diagnostics Test Types Local Channel Loop Remote Channel Loop Control Signal Loop CCITT Rec. V.54 Loops PRBS Transmission BERT Testing Recommended Test Sequence Appendix A. Connection Data KHS.1 i

6 Table of Contents Installation and Operation Manual ii KHS.1

7 Chapter 1 Introduction 1.1 Functional Description The KHS.1 module is a high-speed data module for RAD s family of high-speed modular TDM systems, the Kilomux (which includes the following four models: KM- 2000, KM-2004, KM-2100 and KM-2104). The module provides two high-speed synchronous data channels. Each channel can support data rates of 32, 48, 56, 64, 128, 192, 256 or 384 kbps, however the maximum data rate may be limited by the data rate of the Kilomux main link. The channel interface is DCE, and can be independently configured for V.35, RS-530, V.36/RS-422/RS-499 or X.21 operation. Channel data rates as well as all the channel operating parameters are controlled through the Kilomux supervisory port. Programmable timing modes and channel buffers permit connection to all types of digital lines, including digital data services, and ensure data integrity. Each channel has three user-programmable timing modes: DCE: the KHS.1 channel provides the timing signals to the DTE connected to it. DTE1: the KHS.1 channel provides the receive timing signal, and accepts the transmit timing from the equipment connected to the channel. DTE2: the KHS.1 channel accepts the receive and transmit timing signals from the equipment connected to the channel, and buffers and retimes the incoming data. When connected to the national network or to private carrier data lines, e.g., DDS or Kilostream lines, a KHS.1 channel operating in the DTE2 mode can be used as an external timing reference source for the Kilomux unit the module is installed in. The KHS.1 module provides two user-selectable modes of support for the V.24/RS-232 interface control signals: Local control signal support. When local support is enabled, the channel locally supports four interface control signals, that is, the state of the control signals is not transmitted to the remote channel. The locally-supported control signals are as follows: RTS. CTS: can be programmed to follow RTS with a programmable delay, or to be constantly ON. If a channel is disconnected, its CTS line is always OFF, irrespective of the selected mode. DSR: constantly ON, except when the channel is in remote loopback, or under PRBS or BER testing. KHS.1 Functional Description 1-1

8 Chapter 1 Introduction Installation and Operation Manual DCD: constantly ON, except when communications are not possible because of loss of frame synchronization. End-to-end transmission of local RTS line state to the remote DCD line, and vice versa. Typical end-to-end delay is 2.5msec. The support mode can be independently selected for each channel. The support mode can be independently selected for each channel. The module automatically performs self-test upon power-up and during normal operation. Comprehensive diagnostic capabilities reduce downtime to a minimum. Diagnostics include local and remote channel loops, and in addition the channels support loops 2 and 3 per CCITT Rec. V.54. During maintenance, the activity of the channel transmit and receive lines, and the state of the RTS and DCD control lines can be monitored on the dedicated Kilomux front-panel indicators. Each channel terminates on a separate 25-pin D-type, female connector. Pin-out assignment is in accordance with RS-530 specifications. Local support of four control signals is provided. For connection to V.35, X.21 or RS-422/RS-449 equipment, special cables are available. Figure 1-1 shows typical KHS.1 applications. Figure 1-1. Typical KHS.1 Application 1-2 Functional Description KHS.1

9 Installation and Operation Manual Chapter 1 Introduction 1.2 Technical Specifications Number of channels Interface type Connectors Two V.35, RS-530, V.36/V.11, RS-449/RS-422 or X.21, DCE Two 25-pin D-type, female Cable interface converters are available for connection to V.35, V.36, X.21 or RS-422/RS-449 physical connectors Pin assignment Bit rate Data Clamp Bandwidth allocation on main link Per EIA RS-530 Selectable 32, 48, 56, 64, 128, 192, 256 or 384 kbps Mark hold on out of sync Permanent, according to programmed channel bit rates Control signals Local support End-to-end Clock options RTS-CTS delay software-controlled, DSR, DCD RTS-DCD: 2.5msec typical delay DCE, DTE1, DTE2 Diagnostic tests Self-test Software-controlled tests Automatic self-test upon power-up and during normal operation Local channel loopback Remote channel loopback PRBS transmission BERT testing (Kilomux-2000/2004 only) CCITT Rec. V.54 pin control Local loopback (V.54 loop 3) Remote loopback (V.54 loop 2) Indicators Configuration Monitoring of the TX, RX, RTS and DCD lines of a selected channel on dedicated Kilomux front panel indicators Programmable via a supervision terminal, or a RADview management system KHS.1 Technical Specifications 1-3

10 Chapter 1 Introduction Installation and Operation Manual 1-4 Technical Specifications KHS.1

11 Chapter 2 Installation and Operation 2.1 General This chapter provides installation, configuration and operation instructions for the KHS.1 module. The information presented in this chapter supplements the general Kilomux installation, configuration and operation instructions contained in the Kilomux-2100/2104 Installation and Operation Manual. Caution The KHS.1 module contains components sensitive to electrostatic discharge (ESD). To prevent ESD damage, always hold the module by its sides, and do not touch the module components or connectors. Rear Panel 2.2 Installation The rear panel of the KHS.1 module is shown in Figure 2-1. The module has two 25-pin connectors, one for each channel. Connector pin assignments and functions are given in Appendix A. Internal Settings The KHS.1 module has two small plug-in daughter boards called interface changer boards, one for each channel. Their function is to select the channel interface. All the other module functions are programmable. Figure 2-2 identifies the position of the interface changer boards. KHS.1 Installation 2-1

12 Chapter 2 Installation and Operation Installation and Operation Manual KHS.1 CH.1 Channel 1 Connector CH.2 Channel 2 Connector Figure 2-1. Rear Panel CH.1 V.35 J2B J2A Channel 1 Interface Changer V.35 J2 RS-422 RS-422 J3 J3B J3A CH.2 RS-422 J4B J4A Channel 2 Interface Changer V.35 J4 RS-422 J5 J5B J5A Figure 2-2. Internal Settings 2-2 Installation KHS.1

13 Installation and Operation Manual Chapter 2 Installation and Operation Channel Interface Selection The selection of the channel interface is made by plugging the corresponding interface changer board into one of the connector pairs J2, J3 or J4, J5, in accordance with the required interface. Table 2-1 lists the required settings. Table 2-1. Selection of Channel Interface Interface Settings Channel Position of Changer Board V.35 1 In connector J2 2 In connector J4 RS-530, X.21, V.36, RS-449, RS In connector J3 (default position) 2 In connector J5 (default position) Changer Board Setting Procedure Identify the positions of the changer boards in Figure 2-2. Check the required interface for each channel. If a different interface is required, pull the corresponding changer board out and move it to the appropriate connector. When inserting the changer board, pay attention to correct orientation (do not turn the board around), and proper insertion in the connector. Module Installation Refer to the system installation plan and insert the module in the assigned I/O slot of the Kilomux enclosure. The module starts operating as soon as it is plugged into an operating Kilomux enclosure. Cable Connections Identify the cables intended for connection to the channels of this module, and connect each cable to the appropriate module connector. The required cables can be prepared in accordance with the channel connector wiring information given in Appendix A. However, ready-made cables are also available from RAD Data Communications. The available cables and the use of each cable are listed in Table 2-2. KHS.1 Installation 2-3

14 Chapter 2 Installation and Operation Installation and Operation Manual Table 2-2. Interface Cables Cable Purpose Channel Interface User Equipment Length CBL-HS2V1 V.35 DCE V.35 DTE 2 meters (6 feet) CBL-HS2V2 V.35 DTE1 V.35 DCE 2 meters (6 feet) CBL-HS2V3 V.35 DTE2 V.35 DCE 2 meters (6 feet) CBL-HS2R1 RS-422 DCE RS-422 DTE 2 meters (6 feet) CBL-HS2R2 RS-422 DTE1 RS-422 DCE 2 meters (6 feet) CBL-HS2R3 RS-422 DTE2 RS-422 DCE 2 meters (6 feet) CBL-530T/21C RS-422 DTE, DCE X.21 DCE, DTE 0.3 meters (1 feet) 2.3 Configuration Introduction This section provides specific instructions for the configuration of the KHS.1 module using a supervision terminal. The instructions appearing in this section assume you are familiar with the operation and capabilities of the supervision terminal. If necessary, refer to Chapter 4 of the Kilomux-2100/2104 Installation and Operation Manual for general operating instructions, and for instructions on the execution of other configuration activities. The configuration functions applicable to the KHS.1 module are listed below: Inclusion of a KHS.1 module not yet installed in the Kilomux database. This allows the pre-programming of the module parameters, so when the module is installed in the enclosure, it will immediately start operating in the desired mode. This function is performed by means of the DEF SYS command. Selection of the main link to be used by the module, and when applicable, module priority. This function is performed using the DEF CON command. This command is available only on the Kilomux-2000/2100, provided it is operating in the dual-link, priority bumping or switched-backup mode (but not in the single link or redundancy modes). Programming of the module channel parameters, using the DEF CH command. Before starting the configuration procedure, obtain the list of prescribed channel parameters from your system administrator. 2-4 Configuration KHS.1

15 Installation and Operation Manual Chapter 2 Installation and Operation Configuration Instructions If the supervision terminal is not yet connected to the Kilomux, connect the terminal and start a configuration session in accordance with Chapter 4, Section 4-4 of the system manual. Inclusion of KHS.1 Module in Database If the KHS.1 module to be configured is not yet installed in the Kilomux, type: DEF SYS <Enter> The system parameters data form is displayed. A typical form for a Kilomux-2100 is shown below. The form presents the current parameter values as defaults. CLK_MASTER CLK_FBACK DWLD_BW_A DWLD_BW_B ML_MODE ML_RECOVERY FRAME_MODE N/A N/A NO NO SW_BACK AUTO AUTO Assuming that the only necessary changes are the inclusion of a new KHS.1 module in the system database, press >. The second line of the system parameters data form is displayed. A typical data form for a Kilomux-2100 is shown below: IO : TYPE(DB): KHS Note If the desired slot number is not shown, press <Enter> once or twice, until the desired group of slot numbers is displayed. Press the spacebar to move the cursor to the desired slot number, and then press F or B to scroll among the available selections. When the desired selection (KHS.1) is displayed, press the space bar to move to the next field. After the desired selections are made, press > to end. The supervision terminal will display the time and date fields, followed by the Kilomux prompt. Selection of Main Link and Priority (Kilomux-2000/2100 only) Note Skip this section if the main link mode is SINGLE or REDUNDANCY. This section describes the process of selecting main link and priority in the Kilomux-2000 (KCL.1). If you are using the Kilomux-2100 (KCL.2), see Appendix F of the Kilomux-2100/2104 Installation and Operation Manual. To define the main link and/or priority of a selected KHS.1 module, type: DEF CON <Enter> The connections table is displayed. The table lists the I/O slots and the main link currently used by each module, as well as the priority assigned to each module when a flip occurs from main link A to main link B and from main link B to main link A. A typical display is shown below: I/O GROUP OPERATED_HIGHWAY PB[A->B] PB[B->A] SWITCH ============================================================== KHS.1 Configuration 2-5

16 Chapter 2 Installation and Operation Installation and Operation Manual OP ALL ML-A LOW N/A N/A 1 ALL ML-A HIGH N/A N/A 2 ALL ML-A HIGH N/A N/A 3 ALL ML-A LOW N/A N/A 4 ALL ML-A LOW N/A N/A 5 ALL ML-A LOW N/A N/A 6 ALL ML-A LOW N/A N/A 7 ALL ML-A LOW N/A N/A 8 ALL ML-A LOW N/A N/A 9 ALL ML-A LOW N/A N/A 10 ALL ML-A LOW N/A N/A 11 ALL ML-A LOW N/A N/A 12 ALL ML-A LOW N/A N/A Column PB[A->B]: In use in Priority Bumping and Switched Backup main link modes. High This module will switch to main link B when a main link flip occurs. Low This module will not switch to main link B when a main link flip occurs. Column PB[B->A]: In use in Priority Bumping main link mode. High This module will switch to main link A when a main link flip occurs. Low This module will not switch to main link A when a main link flip occurs. Column SWITCH: In use in Switch, Dual Switch, Single and Switch main link modes when SWITCH_ MODE is configured as AUTO. High Switched main link will establish an ISDN connection on request from this module. Low Switched main link will ignore request from this module for an ISDN connection. If priority bumping and switched backup are disabled, columns PB[A->B] and PB[B->A] show N/A for all the slots. Use the space bar to move the cursor to the number of the slot in which the desired module installed, and press the F or B key to change the main link. Use the space bar and the F and B keys to change the priorities as necessary. If the two main links operate at the same data rate, the Kilomux-2100 automatically sets the same priorities for flips in either direction. Then this line shows N/A for all the slots. If the data rates of the two main links are different and the priority bumping mode is used, you can select the priorities for each I/O slot using the same procedure as above. When done, press <Enter>. After the desired parameter values are selected, press > to end. The supervision terminal will display the time and date fields, followed by the Kilomux-2100 prompt. 2-6 Configuration KHS.1

17 Installation and Operation Manual Chapter 2 Installation and Operation Channel Configuration To start the configuration of a specific channel of a KHS.1 module, enter the command: DEF CH A:B where A is the number of the module slot (7 to 18 for Kilomux-2000, or 1 to 4 for Kilomux-2004), and B is the desired module channel (1 or 2). The supervision terminal displays the channel configuration data form. A typical data form for a KHS.1 module is shown below: SPEED PROTOCOL ASYNC_DATA TIMING CTRL_SIG CTS RTS_CTS_DEL 9.6KBPS ASYNC 8 BITS DCE LOCAL ON MIN Note For a description of parameters and their allowed range of values, refer to Section 2-3. Change parameters as follows: Bring the cursor to the beginning of the first field to be changed by pressing the spacebar. To change the selected field, press F or B to scroll among the available selections. When the desired selection is displayed, press the spacebar to move to the next field. After the desired parameter values are selected, press <Enter> to end. The supervision terminal will display the time and date fields, followed by the Kilomux prompt. Note To avoid problems of compatibility issues between the Kilomux main link and KHS.1 (see Table 2-4). Table 2-3. Compatibility of Main Link and KHS.1 Data Rates KML Data Rate KHS.1 Data Rate [kbps] [kbps] KHS.1 Configuration 2-7

18 Chapter 2 Installation and Operation Installation and Operation Manual Channel Parameters Table 2-3 lists the KHS.1 channel parameters that can be configured. Table 2-4. Channel Parameters Designation Function Values SPEED Determines the channel data rate NC: Channel not connected 32 kbps 48 kbps 56 kbps 64 kbps 128 kbps 192 kbps 256 kbps 384 kbps Default: NC Note: Some channel rate and main link rate combinations may not be supported, see Table 2-1. TIMING CTRL_SIG CTS RTS_CTS_DEL Selects the data channel timing mode. Determines the handling of control signals by the data channel being configured. Selects the state of the CTS line in the user data channel. Controls the delay between the RTS and CTS control signals when the CTS=RTS mode is selected. DCE: Kilomux-2000 operates as a DCE and provides transmit and receive clocks to the synchronous user DTE. DTE1: Kilomux-2000 supplies the receive clock to the user equipment and accepts the user transmit clock. DTE2: Kilomux-2000 requires transmit and receive clocks from the user equipment. Default: DCE LOCAL: End-to-end transmission of control signals is disabled. Only local support is enabled RTS: The state of the local RTS line is transmitted to the remote DCD line. Default: LOCAL ON: CTS continuously on =RTS: CTS line follows the RTS line Default: When the channel is connected: ON When the channel is not connected: OFF MIN: Minimal delay (approximately 2.5 msec) 10 msec 50 msec 100 msec 200 msec Default: MIN 2-8 Configuration KHS.1

19 Installation and Operation Manual Chapter 2 Installation and Operation Considerations in the Selection of the CTS and RTS_CTS_DEL Parameters The selection of the parameters CTS and RTS_CTS_DEL depends on the specific requirements of each application. When analyzing your requirements, take into consideration the following recommendations that can help increase the throughput: When the application requires the transfer of the local RTS to the remote DCD, always select CTS=RTS and select MIN for RTS_CTS_DEL. There is no need to delay the CTS with respect to RTS, because in this case when a data transmission is started (i.e., the RTS line is switched to ON), the remote end will start receiving data only after the remote DCD line is switched to ON. In a multidrop configuration, such as that shown in figure 2-3, when CTS=RTS, it is necessary to select a RTS-CTS delay longer than the RTS-CTS delay of modem A. This is necessary because when the DTE connected to the West Kilomux signals the start of a transmission by setting its RTS line ON, there is a delay before modem A (that receives the RTS signal from the DCD line of the East Kilomux) returns ON on the CTS line. The West KILOMUX must therefore delay the CTS to the DTE by an interval, which is greater than the modem A RTS-CTS delay. If the delay is shorter, modem A will not transmit the beginning of the data transmission. KILOMUX-2000 West KILOMUX-2000 East Modem Modem A KHS.1 KHS.1 DTE Modem Control Signals DTE KHS.1 Channel RTS RTS CTS CTS Control Signals KHS.1 Channel Modem RTS DCD DCD RTS CTS CTS Figure 2-3. Multidrop Configuration Example KHS.1 Configuration 2-9

20 Chapter 2 Installation and Operation Installation and Operation Manual 2-10 Configuration KHS.1

21 Chapter 3 Alarms and Diagnostics 3.1 General This chapter provides information on the alarms generated by the KHS.1 module, and instructions for using the module-specific diagnostic functions. The diagnostic information presented in this chapter supplements the general Kilomux diagnostics operation instructions contained in Chapters 3 thru 6 of the Kilomux-2100/2104 Installation and Operation Manual. 3.2 Alarm Messages Table 3-1 lists the alarm messages generated by the KHS.1 module specifies their type (event or state), and explains their interpretation. The alarm messages generated by the KHS.1 module that are displayed by a supervision terminal connected to the Kilomux are listed in Chapter 4 of the Kilomux-2100/2104 Installation and Operation Manual. Table 3-1. KHS.1 Alarm Messages Alarm Message Type Interpretation HARDWARE ERROR State A KHS.1 hardware failure has been detected during the self-test. PHASOR OVERFLOW Event Phasor overflow occurred. This usually happens because of clock rate differences, caused by incorrect selection of system timing modes KHS.1 Alarm Messages 3-1

22 Chapter 3 Alarms and Diagnostics Installation and Operation Manual 3.3 Diagnostics The available functions are: Activation of a local or remote loop on the desired channel. Indication of the state of the lines that control the activation of CCITT Rec. V.54 loop 2 and loop 3 on the desired channel. Pseudo-random sequence (PRBS) transmission on the desired channel. Bit error rate test (BERT) with automatic remote loopback on the remote Kilomux channel (supported by Kilomux-2000/2004 system only). Monitoring of activity on the channel transmit and receive lines, and monitoring of the channel RTS and DCD lines by means of the Kilomux frontpanel indicators. The following sections describe the available test activities. For front-panel test activation instructions, refer to Chapter 3, Section 3-12 in Part I of this manual. For instructions on the activation of tests using a supervision terminal, refer to Chapter 4 in Part I. Test Types Local Channel Loop When a local loop is activated on a KHS.1 channel, the channel transmit signal is returned to the channel receive path. The transmit signal is still connected to the transmit path and reaches the remote user. While the loop is connected, the local user equipment must receive its own signal. The loop signal path is shown in Figure 3-1. KHS.2 Module User or Test Equipment Channel 1 KHS.1 User or Test Equipment I/O Modules KCL KML KML KCL I/O Modules Local Unit Remote Unit System Management Figure 3.1. Local Channel Loop 3-2 Diagnostics KHS.1

23 Installation and Operation Manual Chapter 3 Alarms and Diagnostics This loop provides a quick check of the connections to the local user equipment. To execute a local channel loop, type the following text into the supervision terminal: LOOP L XX YY Where: XX is the slot number, and YY is the channel number. Remote Channel Loop The signal path depends on the downloading state: If downloading is enabled and a remote channel loop is activated on a KHS.1 channel of the local Kilomux-2000 unit, the KHS.1 module of the remote Kilomux-2000 unit loops back the channel receive signal toward the local channel. The received signal remains connected as usual to the receive path of that unit. The loop signal path is shown in Figure 3.3A. This loop allows the local user to perform a quick check of the end-to-end transmission on this channel. If downloading is disabled, the remote loop is connected on the local Kilomux unit, i.e., the local KHS.1 module returns the receive signal of the tested channel toward the remote Kilomux. The loop signal path is shown in Figure 3.3 B. This loop allows the remote user to perform a quick check of the end-to-end transmission on this channel. Note Downloading is supported only by the Kilomux-2000/2004 system. To execute a remote channel loop, type the following text into the supervision terminal: LOOP R XX YY Where: XX is the slot number, and YY is the channel number. Note The remote loop does not return the control signals. To receive the control signals, you must also perform the control-signal loop on the far-end Kilomux unit. Control Signal Loop When a control-signal loop is activated on a channel of the KLS.1 module (using the LOOP SIG command), the channel transmit control signals are returned to the channel receive control signals. The transmit control signals are not connected to the transmit path. While the loop is connected, the local user equipment receives its own control-signals. The transmitted data, however is connected to the transmit path and reaches the remote user. The received data path is also unaffected by the loop. The loop path is shown in Figure 3.2. Note The Control Signal loop is supported only by the Kilomux-2100/2104 system. If the Control Signal loop is active, data transfer may be momentarily affected when applying any type of loop command to the adjacent channel. KHS.1 Diagnostics 3-3

24 Chapter 3 Alarms and Diagnostics Installation and Operation Manual Typical Module User or Test Equipment CHANNEL 1 User or Test Equipment Local KILOMUX-2100 Remote KILOMUX-2100 Figure 3.2: Control Signal Loop To execute a remote channel loop, type the following text into the supervision terminal: LOOP SIG XX YY Where: XX is the slot number, and YY is the channel number. CCITT Rec. V.54 Loops KHS.1 channels support the CCITT Rec. V.54 loops 2 and 3. The state of the corresponding loop activation lines can be displayed to the operator. Loop 3 The channel CCITT Rec. V.54 loop 3 command is sent by the user's DTE, using the dedicated loop 3 activation line in the interface connector of KHS.1 channel. The command activates a local channel loop on the local KHS.1 channel (Figure 3.1). To execute a V.54 loop 3, type the following text into the supervision terminal: LOOP V54.3 ML Loop 2 The channel CCITT Rec. V.54 loop 2 command is sent by the user's DTE, using the dedicated loop 2 activation line in the interface connector of the KHS.1 channel. The response to a CCITT Rec. V.54 loop 2 command depends on the state of the downloading function: If downloading is disabled (or the system in use is Kilomux-2100/2104 and not Kilomux-2000/2004), a CCITT Rec. V.54 loop 2 command has no effect. If downloading is enabled, a CCITT Rec. V.54 loop 2 command results in the activation of a remote channel loop (on the remote Kilomux-2000 channel, as shown in Figure 3.3A). Note Downloading is supported only by the Kilomux-2000/2004 system. 3-4 Diagnostics KHS.1

25 Installation and Operation Manual Chapter 3 Alarms and Diagnostics To execute a V.54 loop 2, type the following text into the supervision terminal: LOOP V54.2 ML KHS.1 Module Channel 1 User or Test Equipment User or Test Equipment KHS.1 I/O Modules KCL KML KML KCL I/O Modules Local Unit Remote Unit System Management A. Downloading Enabled KHS.1 Module User or Test Equipment Channel 1 KHS.1 User or Test Equipment I/O Modules KCL KML KML KCL I/O Modules Local Unit Remote Unit System Management B. Downloading Disabled Figure 3.3. Remote Channel Loop KHS.1 Diagnostics 3-5

26 Chapter 3 Alarms and Diagnostics Installation and Operation Manual PRBS Transmission The PRBS transmission function is used to provide a test signal to a selected channel of the KHS.1 module. By activating a local or remote main link loop, or a remote channel loop (or by connecting an external loop) while PRBS transmission is activated, this function can also be used to obtain a qualitative evaluation of data transmission without using external test equipment. Data transmission is checked by applying a (511) bit pseudo-random sequence generated by an internal test sequence generator to the input of the tested channel transmit path. The transmitted data is returned by means of a loop somewhere along the data path (e.g., by connecting a remote channel loop if downloading is enabled, or a local main link loop) to the receive path of the module. The received signal is routed to a test sequence evaluator. The evaluator compares the received data, bit by bit, to the original data and detects any difference (bit error). The output of the evaluator is sampled during module polling, to check whether errors were detected in the interval between consecutive pollings. The test results are displayed on a supervision terminal, the test results are displayed as a number in the range of 0 (no errors detected during the current measurement interval) thru The number of errors is accumulated from the activation of the PRBS transmission. During PRBS transmission, the tested channel is disconnected from the user data equipment, and the DSR line is turned off on the local side (the DSR line of the user equipment connected to the remote Kilomux module will not be disconnected). Only one PRBS or BERT test can be activated at any time on each KHS.1 module installed in the Kilomux unit. BERT Testing The BERT test is used to evaluate data transmission through a selected channel of the KHS.1 module without using external test equipment. The BERT test can be activated only when the downloading function is enabled, and the link to the remote Kilomux-2000/2004 operates normally. The BERT test is similar to the PRBS transmission test, except that before the evaluation of the received data starts, a remote channel loop is activated. This should cause the sequence to be transmitted along the full path. The test results are displayed as for PRBS transmission. Note This feature is supported only by Kilomux-2000/2004 systems. As for PRBS transmission, the BERT test can be activated on only one channel of each KHS.1 module installed in the Kilomux-2000/2004 unit, the tested channel is disconnected from the user data equipment, and its DSR line is turned off on the local side. 3-6 Diagnostics KHS.1

27 Installation and Operation Manual Chapter 3 Alarms and Diagnostics Recommended Test Sequence The loops available on the KHS.1 module provide a rapid and efficient way to identify the general location of a fault at either of the two KHS.1 channels connected in a link, or in the external equipment or connections to channels. If a complaint is received from one of the users connected to a KHS.1 channel, first activate the KHS.1 local test loop at the side where the complaint is received. The local user must receive its own signal. If the signal is not received, the problem is at the local end: Check the connections to the user equipment, or the equipment itself. Replace the local KHS.1 module. If the local user receives its own signal when the local loop is activated, the problem is at the remote end. To check, deactivate the local loop and repeat the procedure on the remote Kilomux. KHS.1 Diagnostics 3-7

28 Chapter 3 Alarms and Diagnostics Installation and Operation Manual 3-8 Diagnostics KHS.1

29 Appendix A Connection Data Table A-1. Channel Connector Wiring Pin Designation Direction Function 1 FGND Frame ground 2 TD(A) IN TX data - A wire 3 RD(A) OUT RX data - A wire 4 RTS(A) IN Request to send - A wire 5 CTS(A) OUT Clear to send - A wire 6 DSR(A) OUT Data set ready - A wire 7 SGND Signal ground 8 DCD(A) OUT Carrier detect - A wire 9 RC(B) OUT RX CLK - B wire 10 DCD(B) OUT Carrier detect - B wire 11 ETC(B) IN External TX CLK - B wire 12 TC(B) OUT TX CLK - B wire 13 CTS(B) OUT Clear to send - B wire 14 TD(B) IN TX data - B wire 15 TC(A) OUT TX CLK - A wire 16 RD(B) OUT RX data - B wire 17 RC(A) OUT RX CLK - A wire 18 LLB IN Local loop 19 RTS(B) IN Request to send - B wire 20 ERC(A) IN External RX CLK - A wire 21 RLB IN Remote loop 22 DSR(B) OUT Data set ready - B wire 23 ERC(B) IN External RX CLK - B wire 24 ETC(A) IN External TX CLK - A wire 25 TM OUT Test mode KHS.2 Connection Data A-1

30 Appendix A Connection Data Installation and Operation Manual Note When using the V.35 interface, the control signals use only the A wire. In the direction field: IN input to KHS.1 OUT output from KHS.1 A-2 Connection Data KHS.2

31 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel Tel: , Fax , Web site: Customer Response Form RAD Data Communications would like your help in improving its product documentation. Please complete and return this form by mail or by fax or send us an with your comments. Thank you for your assistance! Manual Name: KHS.1 Publication Number: /08 Please grade the manual according to the following factors: Excellent Good Fair Poor Very Poor Installation instructions Operating instructions Manual organization Illustrations The manual as a whole What did you like about the manual?

32

33 Error Report Type of error(s) or problem(s): Incompatibility with product Difficulty in understanding text Regulatory information (Safety, Compliance, Warnings, etc.) Difficulty in finding needed information Missing information Illogical flow of information Style (spelling, grammar, references, etc.) Appearance Other Please list the exact page numbers with the error(s), detail the errors you found (information missing, unclear or inadequately explained, etc.) and attach the page to your fax, if necessary. Please add any comments or suggestions you may have. You are: Who is your distributor? Your name and company: Job title: Address: Direct telephone number and extension: Fax number: Distributor End user VAR Other

34

35

36 Publication No /08 International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel Fax , North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel Toll free Fax The Access Company

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE Installation and Operation Manual HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation MEGAPLEX-2100 MODULE MEGAPLEX-2100 MODULE HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation

More information

Installation and Operation Manual HS-Q/N. 4-Channel High Speed Data Module MEGAPLEX-2100 MODULE

Installation and Operation Manual HS-Q/N. 4-Channel High Speed Data Module MEGAPLEX-2100 MODULE Installation and Operation Manual HS-Q/N 4-Channel High Speed Data Module MEGAPLEX-2100 MODULE HS-Q/N 4-Channel High Speed Data Module Installation and Operation Manual Notice This manual contains information

More information

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice MEGAPLEX-2100 MODULE VC-1A 1-Channel PCM/ADPCM Voice Module Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications No part of this publication

More information

VC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules

VC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules 4, 8 or 16 analog voice channels using 64 kbps toll-quality PCM encoding; 24/32 kbps ADPCM encoding option for 4- and 8-channel modules E&M, FXS or FXO interface options Caller ID A-law or μ-law companding

More information

This manual may be copied in any form including electronic. It may not be modified in any way without the express permission of CTC Union

This manual may be copied in any form including electronic. It may not be modified in any way without the express permission of CTC Union USER S GUIDE This manual may be copied in any form including electronic. It may not be modified in any way without the express permission of CTC Union Technologies Co. Ltd. Description G703/64A I/F Converter

More information

OPERATION MANUAL INSTALLATION AND VC-4/OMNI. Omnibus PCM Voice Module. Megaplex-2100/2104 Version 12, Megaplex-4100 Version 1.6. The Access Company

OPERATION MANUAL INSTALLATION AND VC-4/OMNI. Omnibus PCM Voice Module. Megaplex-2100/2104 Version 12, Megaplex-4100 Version 1.6. The Access Company INSTALLATION AND OPERATION MANUAL VC-4/OMNI Omnibus PCM Voice Module Megaplex-2100/2104 Version 12, Megaplex-4100 Version 1.6 The Access Company VC-4/OMNI Omnibus PCM Voice Module Megaplex-2100/2104 Version

More information

Kilomux-2100/2104 KVF.4 2-Channel Low Bit Rate Voice/Fax Module

Kilomux-2100/2104 KVF.4 2-Channel Low Bit Rate Voice/Fax Module Data Sheet Kilomux-2100/2104 KVF.4 High quality voice at 4.8, 6.4, 7.2, 9.6 or 12.8 kbps Fax Group III support with automatic rate fallback Double compression (tandeming) Transfers modem data relay at

More information

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL Version 1 Copyright 2005 by S-Access GmbH. The contents of this publication may not be reproduced in any part or as a whole,

More information

Atrie WireSpan 600/610 MODEM User's Manual

Atrie WireSpan 600/610 MODEM User's Manual Atrie WireSpan 600/610 MODEM User's Manual WireSpan 600 / 610 Fractional E1 Access Unit Installation and Operation manual CONTENTS CHAPTER 1 Interduction.. 1-1 CHAPTER 2 Installation and Setup.. 2-1 CHAPTER

More information

VC-6 6-Channel PCM Voice Module MEGAPLEX-2100 MODULE

VC-6 6-Channel PCM Voice Module MEGAPLEX-2100 MODULE Installation and Operation Manual VC-6 6-Channel PCM Voice Module MEGAPLEX-2100 MODULE MEGAPLEX-2100 MODULE VC-6 6-Channel PCM Voice Module Installation and Operation Manual Notice This manual contains

More information

Installation and Operation Manual VC-6A. 6-Channel PCM/ADPCM Voice Module MEGAPLEX-2100 MODULE

Installation and Operation Manual VC-6A. 6-Channel PCM/ADPCM Voice Module MEGAPLEX-2100 MODULE Installation and Operation Manual VC-6A 6-Channel PCM/ADPCM Voice Module MEGAPLEX-2100 MODULE VC-6A 6-Channel PCM/ADPCM Voice Module Installation and Operation Manual Notice This manual contains information

More information

Miniature Synchronous Multipoint Modems

Miniature Synchronous Multipoint Modems ME1735A-F JULY 2003 Miniature Synchronous Multipoint Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours

More information

Interface converter G kbit/sec

Interface converter G kbit/sec converter User s Guide 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901 Interface converter G.703.1 64 kbit/sec Features Maximum line attenuation

More information

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment) NETWORK INTERFACING TE NT NETWORK NT TE Interface Interface TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment) Interface

More information

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable). BLACK BOX PWR RTS TD-1 RD-1 TD-2 DCD RD-2 TEST DIG ANA REM LDM-MR 19.2 REM ANA DIG AGC 2/4 WIRE ABLE / ABLE SWITCHES 2 W 4 W 1 2 3 4 CARRIER LEVEL 0 dbm -3 dbm -6 dbm -9 dbm PIN 21 (RLB) RPF PIN 18 AN.

More information

Modem E1. Modem-converter E1-L. Features. Contents

Modem E1. Modem-converter E1-L. Features. Contents Modem-converter E1-L User s Guide 1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234567 Modem E1 Features E1 G703/G704 channel Distance up to 1.5 km V.35/RS-530/RS-449/RS-232/X.21/

More information

USER'S MANUAL. Model : K

USER'S MANUAL. Model : K USER'S MANUAL Model : 2000-64K TM GINA MODEL 2000-64K Overview GINA Model 2000-64K is a stand-alone, high frequency data transceiver using spread spectrum technology. GINA 2000-64K capabilities include

More information

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual Revision G Copyright 2017 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com E031130243 PROPRIETARY DATA All data

More information

Airmux-200 Wireless Broadband Multiplexer

Airmux-200 Wireless Broadband Multiplexer Data Sheet Airmux-200 Point-to-point and multi point-to-point radio solution for combined TDM and Ethernet traffic over license-free frequencies Cost effective multi point-to-point encrypted wireless broadband

More information

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved A50/A51/A60 June 2008 (4th Edition) All Rights Reserved Part I - A50/A51 RS-232 to RS-422/RS-485 Converter A50/A51 RS-232 to RS-422/RS-485 Bidirectional Converter Part II - A60 RS-232 Surge Protection

More information

TTU01/V35 TTU01/X21 TTU01/449 TTU01/530

TTU01/V35 TTU01/X21 TTU01/449 TTU01/530 TTU01/V35 TTU01/X21 TTU01/449 TTU01/530 DS1/V.35 Interface DS1/X.21 Interface DS1/RS449 (V.36) Interface DS1/RS530 Interface DS1 CSU/DSU Unit DS1/E1 Standalone rack mountable series Table of Contents

More information

FOM-5A, 6A Asynchronous Fiber Optic Modems

FOM-5A, 6A Asynchronous Fiber Optic Modems ORDERING FOM-5A/*/+ Asynchronous Sub-miniature Fiber Optic Modem FOM-6A/*/+/# Asynchronous Miniature Fiber Optic Modem * Specify: F for female 25-pin connector M for male 25-pin connector + Specify: ST

More information

)454 6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU

)454 6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU INTERNATIAL TELECOMMUNICATI UNI )454 6 TELECOMMUNICATI STANDARDIZATI SECTOR OF ITU $!4! #/--5.)#!4)/. /6% 4(% 4%,%0(/.%.%47/+,//0 4%34 $%6)#%3 &/ -/$%-3 )454 Recommendation 6 (Extract from the "LUE "OOK)

More information

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up. DSP4xxFP SA USER S MANUAL A01561 Rev. A This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA700425 and up. DSP4xxSA User s Manual A01561 Rev. X Proprietary Data This document

More information

KiloStream Data Sheet

KiloStream Data Sheet KiloStream Data Sheet KiloStream speeds The choice of interfaces and speeds shown below enable a wide variety of equipment conforming to CCITT* standards to be connected. Speeds and interfaces Speed kbit/s

More information

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 4WSD9R0712-1/4 Model 4WSD9R Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 The 4WSD9R Universal Converter is a port-powered or externally powered two-channel

More information

VC-4, VC-4A, VC-8, VC-8A, VC-16

VC-4, VC-4A, VC-8, VC-8A, VC-16 INSTALLATION AND OPERATION MANUAL VC-4, VC-4A, VC-8, VC-8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules Megaplex-2100/2104 Version 12.9, Megaplex-4100 Version 2.2 VC-4, VC-4A, VC-8, VC-8A, VC-16

More information

INSTALLATION and OPERATION MANUAL

INSTALLATION and OPERATION MANUAL INSTALLATI and OPERATI MANUAL CTC Union Technologies Co., Ltd. Far Eastern Edison Science and Technology Center 6F-3, No. 15, Lane 360 NeiHu Rd., Section 1 NeiHu, Taipei, 114 Taiwan G703 Pack Series G.703

More information

Concept of Serial Communication

Concept of Serial Communication Concept of Serial Communication Agenda Serial v.s. Parallel Simplex, Half Duplex, Full Duplex Communication RS-485 Advantage over RS-232 Serial v.s. Parallel Application: How to Measure the temperature

More information

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview Modem Overview Page 2.1 DigiPoints Volume 1 Module 2 Modem Overview Summary One of the potential advantages the cable telecommunications industry has is the ability to carry data signals at speeds significantly

More information

Stat-4 Stat-8 Stat-24

Stat-4 Stat-8 Stat-24 JULY 1993 MX864A MX866A MX868A Stat-4 Stat-8 Stat-24 STAT-4 POWER MAIN 1 2 3 4 SYNC ERR OVF TEST 1 2 3 4 RESET STAT-24 STAT-8 POWER MAIN 1 2 3 4 5 6 7 8 SYNC ERR OVF TEST 1 2 3 4 5 6 7 8 TEST SYNC 23 24

More information

FOM-4SF Sync/Async Single Fiber Modem

FOM-4SF Sync/Async Single Fiber Modem ORDERING FOM-4SF/$/+ Sync/async single fiber modem $ Specify DTE interface type: V24 for V.24 interface, female connector V35 for V.35 interface, female connector X.21 for X.21 interface, female connector

More information

Airmux-400 Broadband Wireless Multiplexer (Ver. 2.4)

Airmux-400 Broadband Wireless Multiplexer (Ver. 2.4) Data Sheet For North America Only Airmux-400 Point-to-point and multi point-to-point broadband radio solution for Ethernet and TDM traffic over license-free frequencies Cost-effective multi point-to-point

More information

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM FULL DUPLEX Radio MODEM Direct Cable Replacement Range 2KM RS232 / RS485 / USB Host Data Rates up to 38,400 Baud RF Data Rates to 115200Kbps Waterproof IP68 Enclosure 8 User Selectable Channels CE Compliant

More information

2 Mbit/s and Data Analyzer. Reference Manual

2 Mbit/s and Data Analyzer. Reference Manual 50-13139-01 Rev. B TM 2 Mbit/s and Data Analyzer Reference Manual APRIL 1995 1992 Telecommunications Techniques Corporation 20400 Observation Drive, Germantown, Maryland 20876 (800) 638-2049 or (301) 353-1550

More information

CROSS Chassis from 160 A to 450 A

CROSS Chassis from 160 A to 450 A CROSS Chassis from 160 A to 450 A STS CATALOGUE Important note! The technical data enclosed is for general information. Please note that the operating instructions and references indicated on the products

More information

ZCS485 User s Manual. Version ZYPEX, Inc.

ZCS485 User s Manual. Version ZYPEX, Inc. ZCS485 User s Manual Version 2.2 2004 ZYPEX, Inc. Table of Contents Product Description 1 ZCS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter

More information

APPLICATION NOTE ANI6. Connecting the SP504 Multiprotocol Transceiver to the 85C30 Universal Enhanced Serial Communications Controller (ESCC)

APPLICATION NOTE ANI6. Connecting the SP504 Multiprotocol Transceiver to the 85C30 Universal Enhanced Serial Communications Controller (ESCC) Solved by APPLICATION NOTE ANI6 TM Connecting the SP504 Multiprotocol Transceiver to the 85C30 Universal Enhanced Serial Communications Controller (ESCC) INTRODUCTION The Sipex SP504 is a cost-effective,

More information

SIN 57 Issue 2.4 May 2018

SIN 57 Issue 2.4 May 2018 SIN 57 Issue 2.4 May 2018 Suppliers' Information Note For The BT Network BT KiloStream X.21 Interface Service Description Each SIN is the copyright of British Telecommunications plc. Reproduction of the

More information

Arduino Arduino RF Shield. Zulu 2km Radio Link.

Arduino Arduino RF Shield. Zulu 2km Radio Link. Arduino Arduino RF Shield RF Zulu 2km Radio Link Features RF serial Data upto 2KM Range Serial Data Interface with Handshake Host Data Rates up to 38,400 Baud RF Data Rates to 56Kbps 5 User Selectable

More information

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449 IC237A IC482A JUNE 1995 IC486A IC487A-F Non-Powered Interface Converters S-232 to S-530 S-422 to V.35 S-232 to S-485 S-232 to S-422/S-449 CUSTOME SUPPOT INFOMATION Order toll-free in the U.S. 24 hours,

More information

SV2C 28 Gbps, 8 Lane SerDes Tester

SV2C 28 Gbps, 8 Lane SerDes Tester SV2C 28 Gbps, 8 Lane SerDes Tester Data Sheet SV2C Personalized SerDes Tester Data Sheet Revision: 1.0 2015-03-19 Revision Revision History Date 1.0 Document release. March 19, 2015 The information in

More information

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT ICS ICS ELECTRONICS division of Systems West Inc. AB- APPLICATION BULLETIN SERIAL BACKGROUNDER (Serial 0) INTRODUCTION Serial data communication is the most common means of transmitting data from one point

More information

Model 4xx. Plug-in Series Of FSK Modems USER GUIDE. (TI) 20 Jan 06 DWG: A GDI COMMUNICATIONS LLC PO Box I-80 Exit 1 Verdi, NV 89439

Model 4xx. Plug-in Series Of FSK Modems USER GUIDE. (TI) 20 Jan 06 DWG: A GDI COMMUNICATIONS LLC PO Box I-80 Exit 1 Verdi, NV 89439 Model 4xx Plug-in Series Of FSK s USER GUIDE (TI) 20 Jan 06 DWG: A01164 GDI COMMUNICATIONS LLC PO Box 1330 280 I-80 Exit 1 Verdi, NV 89439 Phone: (775) 345-8000 Fax: (775) 345-8010 Web: www.sgdi.com Email:

More information

BASIC PARAMETERS FOR THE MEASUREMENT OF ERROR PERFORMANCE AT BIT RATES BELOW THE PRIMARY RATE

BASIC PARAMETERS FOR THE MEASUREMENT OF ERROR PERFORMANCE AT BIT RATES BELOW THE PRIMARY RATE INTERNATIONAL TELECOMMUNICATION UNION CCITT O.153 THE INTERNATIONAL TELEGRAPH AND TELEPHONE CONSULTATIVE COMMITTEE (11/1988) SERIES O: SPECIFICATIONS FOR MEASURING EQUIPMENT Equipment for the measurement

More information

InfraStruXure Manager v4.x Addendum: Building Management System Integration

InfraStruXure Manager v4.x Addendum: Building Management System Integration InfraStruXure Manager v4.x Addendum: Building Management System Integration Introduction This addendum explains the integration of the APC InfraStruXure Manager Appliance with a Building Management System

More information

MGE TM Galaxy TM , 60 Hz kva

MGE TM Galaxy TM , 60 Hz kva Home Alarms Online Trend Statistics Rectifier Battery Inverter Bypass AC Bypass Output Set up Normal AC Q4S Load protected QBP QF 0 Hour 50 Min. 5 kva 00% 0% 00% 0 50% Load equipment 0 80% 50% Remote vision

More information

OPEN BASE STATION ARCHITECTURE INITIATIVE

OPEN BASE STATION ARCHITECTURE INITIATIVE OPEN BASE STATION ARCHITECTURE INITIATIVE General Purpose Module (GPM) Specification Version.0 Issue.0 () 0 0 0 0 Preface OBSAI description and specification documents are developed within the Technical

More information

1.0 Introduction. Related Products and Documentation

1.0 Introduction. Related Products and Documentation Quick Start t Guide ER450 Data Radio 1.0 Introduction Welcome to the Quick Start Guide for the ER450 Data Radio. This guide provides step-by-step instructions, with simple explanations to get you up-and-running.

More information

ANALOG AND DIGITAL PHYSICAL INTERFACES

ANALOG AND DIGITAL PHYSICAL INTERFACES ANALOG AND DIGITAL PHYSICAL INTERFACES Habib Youssef, Ph.D youssef@ccse.kfupm.edu.sa Department of Computer Engineering King Fahd University of Petroleum and Minerals Dhahran, Saudi Arabia COMPUTER NETWORK

More information

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V

More information

G3P-R232. User Manual. Release. 2.06

G3P-R232. User Manual. Release. 2.06 G3P-R232 User Manual Release. 2.06 1 INDEX 1. RELEASE HISTORY... 3 1.1. Release 1.01... 3 1.2. Release 2.01... 3 1.3. Release 2.02... 3 1.4. Release 2.03... 3 1.5. Release 2.04... 3 1.6. Release 2.05...

More information

SC16C Description. 2. Features. Dual UART with 32 bytes of transmit and receive FIFOs

SC16C Description. 2. Features. Dual UART with 32 bytes of transmit and receive FIFOs Rev. 04 20 June 2003 Product data 1. Description The is a 2 channel Universal Asynchronous Receiver and Transmitter (UART) used for serial data communications. Its principal function is to convert parallel

More information

VC-4/4A, VC-8/8A, VC-16

VC-4/4A, VC-8/8A, VC-16 Data Sheet Megaplex-4, Megaplex-2100/2104 VC-4/4A, VC-8/8A, VC-16 E&M, FXS or FXO options Caller ID A-law or µ-law companding Optional inband signaling with A-law encoded channels PCM (64 kbps) and ADPCM

More information

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION OVER THE TELEPHONE NETWORK

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION OVER THE TELEPHONE NETWORK INTERNATIONAL TELECOMMUNICATION UNION ITU-T V.24 TELECOMMUNICATION (03/93) STANDARDIZATION SECTOR OF ITU DATA COMMUNICATION OVER THE TELEPHONE NETWORK LIST OF DEFINITIONS FOR INTERCHANGE CIRCUITS BETWEEN

More information

Airmux-400 Broadband Wireless Multiplexer (Ver )

Airmux-400 Broadband Wireless Multiplexer (Ver ) Data Sheet For North America Only Airmux-400 Broadband Wireless Multiplexer (Ver. 2.4.50) Cost-effective multiple point-to-point encrypted broadband wireless multiplexer Point-to-point and multiple point-to-point

More information

Cable and Port Specifications

Cable and Port Specifications APPENDIX D This appendix includes the following information: Cables and Adapters Provided, page D-1 Console Port, page D-2 COM1 Port, page D-3 MGMT 10/100 Ethernet Port, page D-5 SFP Transceiver Specifications,

More information

PULSE INPUT MODULE PI232/PI272 USER S MANUAL

PULSE INPUT MODULE PI232/PI272 USER S MANUAL UM-TS02 -E021 PROGRAMMABLE CONTROLLER PROSEC T2-series PULSE INPUT MODULE PI232/PI272 USER S MANUAL TOSHIBA CORPORATION Important Information Misuse of this equipment can result in property damage or human

More information

MDR24x Wireless 2.4GHz Modem

MDR24x Wireless 2.4GHz Modem MDR24x Wireless 2.4GHz Modem User s Manual Version 1.1 1000 Park Drive Lawrence, PA 15055-1018 Website: www.blackbox.com Email: info@blackbox.com Order Toll Free in the US: Call 877-877-BBOX (Outside the

More information

TS4000 Radio Modem. User s Manual

TS4000 Radio Modem. User s Manual TS4000 Radio Modem User s Manual Version 6.60C 1729 South Main Street Milpitas, CA 95035 (408) 941-1808 (800) 663-3674 (408) 941-1818 Fax www.teledesignsystems.com productsales@teledesignsystems.com techsupport@teledesignsystems.com

More information

EIA-232 Information. DTE Signal Direction. DCE Signal Direction. Signal EIA

EIA-232 Information. DTE Signal Direction. DCE Signal Direction. Signal EIA EIA EIA-232 Information This is one of the most misunderstood areas of RS-232. DTE stands for Data Terminal Equipment, and DCE stands for Data Circuit-terminating Equipment or Data Communications Equipment.

More information

ROM/UDF CPU I/O I/O I/O RAM

ROM/UDF CPU I/O I/O I/O RAM DATA BUSSES INTRODUCTION The avionics systems on aircraft frequently contain general purpose computer components which perform certain processing functions, then relay this information to other systems.

More information

Superseded by a more recent version INTERNATIONAL TELECOMMUNICATION UNION

Superseded by a more recent version INTERNATIONAL TELECOMMUNICATION UNION INTERNATIONAL TELECOMMUNICATION UNION ITU-T V.24 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/96) SERIES V: DATA COMMUNICATION OVER THE TELEPHONE NETWORK Interfaces and voiceband modems List of

More information

SC16C550B. 1. General description. 2. Features. 5 V, 3.3 V and 2.5 V UART with 16-byte FIFOs

SC16C550B. 1. General description. 2. Features. 5 V, 3.3 V and 2.5 V UART with 16-byte FIFOs Rev. 05 1 October 2008 Product data sheet 1. General description 2. Features The is a Universal Asynchronous Receiver and Transmitter (UART) used for serial data communications. Its principal function

More information

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter Hardware Installation Guide First Edition, August 2013 2013 Moxa Inc. All rights reserved. P/N: 1802012800011 Introduction The ICF-1280I series

More information

ProLink Radio. 900 MHz SDI-12 Data Radio Scienterra Limited. Version A-0x0C-1-AC 20 October 2009

ProLink Radio. 900 MHz SDI-12 Data Radio Scienterra Limited. Version A-0x0C-1-AC 20 October 2009 ProLink Radio 900 MHz SDI-12 Data Radio Scienterra Limited Version A-0x0C-1-AC 20 October 2009 For sales inquiries please contact: ENVCO Environmental Collective 31 Sandringham Rd Kingsland, Auckland 1024

More information

Airmux-400 Broadband Wireless Multiplexer

Airmux-400 Broadband Wireless Multiplexer Data Sheet For North America Only Airmux-400 Point-to-point and multi point-to-point broadband radio solution for Cost-effective multi point-to-point encrypted wireless broadband multiplexer Net throughput

More information

Appendix C T1 Overview

Appendix C T1 Overview Appendix C T Overview GENERAL T refers to the primary digital telephone carrier system used in North America. T is one line type of the PCM T-carrier hierarchy listed in Table C-. T describes the cabling,

More information

CP485-4 User s Manual

CP485-4 User s Manual CP485x4 User s Manual Version 1.0 2005 ZYPEX, Inc. CP485-4 User s Manual Table of Contents Table of Contents Product Description 1 CP485x4 Configuration & Setup 2 Power 2 Baud Rate 2 Control Mode 2 Duplex

More information

USER MANUAL G703FTEC. T1/E1 Cross Rate Converter

USER MANUAL G703FTEC. T1/E1 Cross Rate Converter USER MANUAL G703FTEC T1/E1 Cross Rate Converter CTC Union Technologies Co., Ltd. Far Eastern ViennaTechnology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu Taipei 114, Taiwan G703-FTEC T1/E1

More information

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem 2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6734 RS-232 Optical Modem 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic RS- 232 Data Modem (OTR) in

More information

EDACS SYSTEM MANAGER. User s Guide. Mobile Communications. User s Guide For Version 3.XX (Group 3) LBI-38984

EDACS SYSTEM MANAGER. User s Guide. Mobile Communications. User s Guide For Version 3.XX (Group 3) LBI-38984 Mobile Communications EDACS SYSTEM MANAGER (Enhanced Digital Access Communications System) User s Guide For Version 3.XX (Group 3) User s Guide TABLE OF CONTENTS Page Section/Paragraph INTRODUCTION..................................................

More information

Multiplexer - Voice Transcoder E1-XLC

Multiplexer - Voice Transcoder E1-XLC E1-XLC Multiplexer User s Guide 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901 Multiplexer - Voice Transcoder E1-XLC Features Desktop or the

More information

Fanuc Serial (RS232) Communications Information

Fanuc Serial (RS232) Communications Information Memex Automation Inc. 777 Walkers Line, Burlington, Ontario Canada L7N 2G1 Fanuc Serial (RS232) Communications Information Contents Signal Description Fanuc Serial Cable Information Timing Chart When The

More information

Canoga Traffic Sensing System

Canoga Traffic Sensing System Traffic Sensing System 942 and 944 Traffic Monitoring Cards Traffic Monitoring Card Configuration Software (TMC-CS) Matched Components of the Traffic Sensing System October 2007 942 and 944 Traffic Monitoring

More information

USER MANUAL MODEL 1186 Multi-Mode Fiber Modem with Fixed G.703/G.704 Interface

USER MANUAL MODEL 1186 Multi-Mode Fiber Modem with Fixed G.703/G.704 Interface USER MANUAL MODEL 1186 Multi-Mode Fiber Modem with Fixed Interface C E R T I F I E D An ISO-9001 Certified Company Part# 07M1186-UM Doc# 01716U2-001, Rev. C Revised 10/25/06 SALES OFFICE (301)975-1000

More information

SC16C750B. 1. General description. 2. Features. 5 V, 3.3 V and 2.5 V UART with 64-byte FIFOs

SC16C750B. 1. General description. 2. Features. 5 V, 3.3 V and 2.5 V UART with 64-byte FIFOs Rev. 05 17 October 2008 Product data sheet 1. General description 2. Features The is a Universal Asynchronous Receiver and Transmitter (UART) used for serial data communications. Its principal function

More information

Multi-Channel RS-232 Serial RF Transceiver

Multi-Channel RS-232 Serial RF Transceiver RF-232 Multi-Channel RS-232 Serial RF Transceiver The RF-232 subassembly is a multi-channel serial radio transceiver. This device accepts and outputs standard serial data at one of three selectable data

More information

) #(2/./53 $!4! 42!.3-)33)/.!4! $!4! 3)'.!,,).' 2!4% ()'(%2 4(!. KBITS 53).' K(Z '2/50 "!.$ #)2#5)43

) #(2/./53 $!4! 42!.3-)33)/.!4! $!4! 3)'.!,,).' 2!4% ()'(%2 4(!. KBITS 53).' K(Z '2/50 !.$ #)2#5)43 INTERNATIONAL TELECOMMUNICATION UNION )454 6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU $!4! #/--5.)#!4)/. /6%2 4(% 4%,%(/.%.%47/2+ 39.#(2/./53 $!4! 42!.3-)33)/.!4! $!4! 3)'.!,,).' 2!4% ()'(%2 4(!.

More information

JBus/Modbus Communication Card

JBus/Modbus Communication Card JBus/Modbus Communication Card Installation and Operation 05/2018 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries

More information

OC-12/STM-4 SFP Multimode Transceivers with Digital Diagnostics

OC-12/STM-4 SFP Multimode Transceivers with Digital Diagnostics OC-/STM- SFP Multimode Transceivers with Digital Diagnostics TRPAMM Product Description The TRPAMM SFP fiber optic transceivers with integrated digital diagnostics monitoring functionality provide a quick

More information

RFL-SHFI and SHFI-2 Module. C37.94 Short Haul Fibre Interface for UMUX. User Manual

RFL-SHFI and SHFI-2 Module. C37.94 Short Haul Fibre Interface for UMUX. User Manual RFL-SHFI and SHFI-2 Module C37.94 Short Haul Fibre Interface for UMUX User Manual RFL Communications plc www.rflcomms.co.uk 01249 446500 Issue Amendment Details Date of Issue By A Release with version

More information

CL4424. Industrial 2.4GHz ConnexLink. User s Manual Version 1.1

CL4424. Industrial 2.4GHz ConnexLink. User s Manual Version 1.1 CL4424 Industrial 2.4GHz ConnexLink User s Manual Version 1.1 11160 THOMPSON AVENUE LENEXA, KS 66215 (800) 492-2320 www.aerocomm.com sales@aerocomm.com Document Information Copyright Information Copyright

More information

AUTOMATION. Operator s Manual. IRU-2xx4/3xx4 Series. Rev. A2, 11/08 Doc

AUTOMATION. Operator s Manual. IRU-2xx4/3xx4 Series. Rev. A2, 11/08 Doc AUTOMATION P R O D U C T S G R O U P, I N C. Operator s Manual IRU-2xx4/3xx4 Series Rev. A2, 11/08 Doc. 9002673 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com IRU-2xx4/3xx4

More information

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections -01-1/ 00 by B&B Electronics. All rights reserved. Model Port-Powered RS- Fiber Optic Modem with Handshake Support Description The allows any two pieces of RS- asynchronous serial equipment to communicate

More information

User Manual 455U-D Radio Modem

User Manual 455U-D Radio Modem User Manual 455U-D Radio Modem ELPRO Technologies Pty Ltd, 9/12 Billabong Street, Stafford Q 4053, Australia. Tel: +61 7 3352 8600 Fax: +61 7 3352 8677 Email: Elpro-Sales@eaton.com Web: www.eaton.com/wireless

More information

SC16C652B. 1. General description. 2. Features. 5 V, 3.3 V and 2.5 V dual UART, 5 Mbit/s (max.) with 32-byte FIFOs and infrared (IrDA) encoder/decoder

SC16C652B. 1. General description. 2. Features. 5 V, 3.3 V and 2.5 V dual UART, 5 Mbit/s (max.) with 32-byte FIFOs and infrared (IrDA) encoder/decoder 5 V, 3.3 V and 2.5 V dual UART, 5 M/s (max.) with 32-byte FIFOs and infrared (IrDA) encoder/decoder Rev. 04 1 September 2005 Product data sheet 1. General description 2. Features The is a 2 channel Universal

More information

OPEN BASE STATION ARCHITECTURE INITIATIVE

OPEN BASE STATION ARCHITECTURE INITIATIVE OPEN BASE STATION ARCHITECTURE INITIATIVE Clock and Control Module (CCM) Specification Version.0 Issue.0 () 0 0 0 0 Preface OBSAI Specification documents are developed within the Technical Working Groups

More information

CL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0. Americas: Europe: Hong Kong:

CL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0. Americas: Europe: Hong Kong: CL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0 Americas: +1-800-492-2320 FCC Notice WARNING: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)

More information

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter USER MANUAL MODEL 2029 Parallel to Serial/ Serial to Parallel Interface Converter C E R T I F I E D An ISO-9001 Certified Company Part #07M2029-B, Rev. C Doc. #102011UB Revised 6/16/09 SALES OFFICE (301)

More information

Serial Communications RS232, RS485, RS422

Serial Communications RS232, RS485, RS422 Technical Brief AN236 Technical Brief AN236Rev A Serial Communications RS232, RS485, RS422 By John Sonnenberg S u m m a r y Electronic communications is all about interlinking circuits (processors or other

More information

SC16C650B. 1. General description. 2. Features. 5 V, 3.3 V and 2.5 V UART with 32-byte FIFOs and infrared (IrDA) encoder/decoder

SC16C650B. 1. General description. 2. Features. 5 V, 3.3 V and 2.5 V UART with 32-byte FIFOs and infrared (IrDA) encoder/decoder 5 V, 3.3 V and 2.5 V UART with 32-byte FIFOs and infrared (IrDA) encoder/decoder Rev. 04 14 September 2009 Product data sheet 1. General description 2. Features The is a Universal Asynchronous Receiver

More information

ECE 4510/5530 Microcontroller Applications Week 6 Lab 5

ECE 4510/5530 Microcontroller Applications Week 6 Lab 5 Microcontroller Applications Week 6 Lab 5 Dr. Bradley J. Bazuin Associate Professor Department of Electrical and Computer Engineering College of Engineering and Applied Sciences Lab 5 Element Hardware

More information

DRG-Series. Digital Radio Gateway. Tait P25 CCDI Tier-2 (TM9400 Series Mobile Radio) Digital Radio Supplement

DRG-Series. Digital Radio Gateway. Tait P25 CCDI Tier-2 (TM9400 Series Mobile Radio) Digital Radio Supplement DRG-Series Digital Radio Gateway Tait P25 CCDI Tier-2 (TM9400 Series Mobile Radio) Digital Radio Supplement DRG-Series Digital Radio Gateway Tait P25 CCDI Tier-2 (TM9400 Series Mobile Radio) Digital Radio

More information

FEATURES PLCC Package RXB RXA -TXRDYB TXA TXB -OPB -CSA -CSB

FEATURES PLCC Package RXB RXA -TXRDYB TXA TXB -OPB -CSA -CSB DUAL UART WITH 16-BYTE TRANSMIT AND RECEIVE FIFO S DESCRIPTION The ST16C2550 (2550) is a dual universal asynchronous receiver and transmitter (UART). The ST16C2550 is an improved version of the NS16C550

More information

Integrity Instruments

Integrity Instruments Integrity Instruments XP-A/I User Manual Integrity Instruments P.O. Box Order Phone 00-0-00 Pine River Minnesota Fax Phone -- USA Tech Phone --0 http://www.integrityusa.com XP-A ISOLATED XP-I RS- to RS-

More information

OVEN INDUSTRIES, INC. Model 5C7-362

OVEN INDUSTRIES, INC. Model 5C7-362 OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...

More information

RFL-SHFI-M Module. C37.94 Short Haul Fibre Interface For Milegate. User Manual

RFL-SHFI-M Module. C37.94 Short Haul Fibre Interface For Milegate. User Manual RFL-SHFI-M Module C37.94 Short Haul Fibre Interface For Milegate User Manual RFL Communications plc www.rflcomms.co.uk 01249 446500 Issue Amendment Details Date of Issue By A Initial Issue 27 Aug 14 PH

More information

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1. RM24100A 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.03 Introduction The RM24100A radio modem acts as a wireless serial cable replacement and

More information

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor 1993 Specifications CSJ 0008-12-071 SPECIAL SPECIFICATION ITEM 6550 Drop/Insert Multiplexor/Demultiplexor 1.0 Description. This Item shall govern for the furnishing and installation of intelligent drop/insert

More information