Since its inception, AC&E has specialised in the development and manufacture of products such as:

Size: px
Start display at page:

Download "Since its inception, AC&E has specialised in the development and manufacture of products such as:"

Transcription

1

2 The aim of this catalogue is to show the range of high quality baluns and balun solutions available from AC&E. We trust that you will find this booklet helpful in sourcing the products you require. Founded in 1967, Australian company AC&E has become a leading manufacturer and supplier of connectivity and interface solutions to the telecommunications, networking, audio/video and Broadcasting Industries. With sales in 64 countries around the world, AC&E catalogue and customized solutions are well recognized. Since its inception, AC&E has specialised in the development and manufacture of products such as: Telecommunication Baluns for 1.5 to 155Mbit/s applications Video Baluns for Surveillance, Security and Broadcast applications Broadband Baluns for TV and CATV applications Coaxial Connectors and U Links primarily in BNC, 1.6/5.6, BT43 and 1.0/2.3 Audio Video Interconnection and Distribution Products Patch Panels Cable Assemblies Alarm Modules, and Power Distribution Modules for Telecommunications Applications Cable TV Products for interface and distribution Broadband Interface and Distribution systems for home, apartment or office AC&E is constantly researching, developing and improving its range of telecommunication products to provide customers world wide with cutting edge technology. In the past year we have significantly improved or created new catalogue products providing improved performance and greater product choice. AC&E is committed to supplying high quality, high reliability product at competitive prices. We work in accordance with quality standard ISO9001:2000 and strive for excellence through total quality management methodology. Please feel welcome to visit our web site, or contact our office (address details on the back cover) with any enquiries you may have. We look forward to assisting you with your requirements and providing a solution to your connectivity and interface needs. Page 2

3 Table of Contents Baluns 4 Introduction 4 Telecommunications Applications 5 Benefits in Converting DDF from Coax to Twisted Pair 5 Generic Single Balun Part Numbering 6 Generic Balun Panel Part Numbering 7 Electrical Characteristics of 2-8Mbits/s, 75/120 Ω Balun 8 Electrical characteristics of Mbits/s 75/120 Ω Balun 9 Standard Baluns 10 Standard Baluns Physical Characteristics Mbits/s 75/120 Ω Transmission Baluns 10 2,8 & 34 Mbits/s 75/120 Ω Transmission Baluns 11 Standard Baluns Termination Procedure 12 Mini Baluns Mbits/s 75/120 Ω Transmission Baluns 13 2,8 & 34 Mbits/s 75/120 Ω Transmission Baluns Mbits/s high speed Mini Balun 14 Mini Balun Termination Procedures 15 Dual Baluns Mbits/s 75/120 Ω Transmission Baluns Mbits/s high speed Mini Balun 16 Dual Balun Cables 17 Balun Panels 18 Ultra High Density Balun Panels 18 High density balun Panels 19 Medium Density Balun Panels 19 Telco Connector Balun Panels 20 Low Density Balun Panels 20 Patch Panels 21 Patch Panel Solutions 21 Blank Panels 21 BNC Panels & Accessories /5.6 Panels & Accessories 21 Customised Requirements 21 Customised Balun Assemblies 22 Quad Balun Assemblies 22 Connector, Integral Balun Pair (ISDN Baluns) 22 DB9 to Coaxial Baluns x E1 Transmission Path Interface Module 23 Balun Cables 24 DDF Solutions 25 Video Baluns 26 Broadband Distribution Systems 27 Notes 28 Glossary 31 page 3

4 Baluns - Introduction An unmatched source and load in a transmission system causes poor energy transfer from one part of the system to the next. Baluns are the ideal solution to this problem as they allow two systems of different characteristic impedance to each see their ideal load and source impedance. This avoids losses caused by mismatch and allows full coupling of the transmitted energy from one part of the system to the next. A common transmission impedance matching problem is interfacing systems with a 75 impedance (typical of many coaxial cables) to systems with a 120 impedance (as in many twisted pair cables). There are many other impedances used in transmission systems. Many modern transmission systems are designed with twisted pair interfaces as they offer higher density interfaces, smaller cable sizes and lower cable costs. The incompatibility with older established 75 systems is overcome with Baluns allowing equipment with different interfaces to co-exist without penalty. AC&E is a company that specializes in connectivity and interface solutions. We design and produce a wide range of Baluns that support transmissions from DC to 1GHz in a variety of connectivity standards and physical configurations that are intended for many different applications. In addition AC&E manufacture baluns in six main housing styles with a wide variety of coaxial and twisted pair interfaces. Coaxial connector types supported include BNC, 1.6/5.6, BT43, 1.0/2.3, APT1000, SMB, PAL, F and BPO10 connectors in male (m), female (f) and a variety attachment styles. Twisted pair terminations include Krone IDC, AC&E s clamp IDC, Screw Terminal, Wire Wrap, Pin Header, Telco, D Connectors and RJ45 s. Reliable long life connections with impedance matching is our business. Our connectivity and interface solution guarantees your signal integrity. This document lists the range of AC&E s catalogue Balun products and is intended as a selection guide. Its contents are subject to change without notice. Our design team is well experienced in quickly producing products to solve a special connectivity and interface problem. Balun Housing The most common housings for AC&E s Catalogue Balun products are:- The Standard Balun which is intended for panel mounting and comes with a variety coaxial interfaces and has an industry standard Krone IDC for twisted pair connection. This product is used to house Baluns for use in the 0 50Mhz signal range. The Mini Balun, a fully shielded product which is intended for either panel or cable mounting, comes with a variety coaxial interfaces and AC&E s Clamp IDC for twisted pair termination. This product houses Baluns for use in the 0 250Mhz signal range. The PCB Balun which is intended for use by equipment makers who need a PCB mounting 75 coaxial interface on their system. The benefit of this solution is that it incorporates impedance transformation and isolation within the same connector footprint. The Broadband Balun is a product whose packaging is optimized for use in impedance matching 50 1,000MHz signals for CATV networks. B B Page 4

5 Dual Baluns. These products provide transformation of a 75 coaxial / pair to two 120 twisted pair outputs on a single RJ45 socket. The product is primarily aimed at interfacing T1/E1 to T3/E3 transmissions. M R2 Balun Panels. These products house multiple Standard or Mini Baluns for users who require a high density of Baluns. The convenience and cost saving of a 19 or similar instrument rack in large and professional systems makes these products a popular choice. Telecommunications Applications AC&E s range of Baluns for telecommunications supports data speeds up to 155Mbit/s and meets or exceeds all the parameters of the ITU G.703 specifications. These Baluns comprise of three Catalogue types:- 2 8Mbit/s speed version (for E1/T1 and E2/T2 data streams) Mbit/s speed version (for E1/T1 to E3 data streams) 34 to 155Mbit/s, high speed version (for E3 and higher data streams) Conversion from coax to twisted pair cables enables the use of high density IDC (insulation displacement connection) modules to be used for distribution frames, increasing the wiring density by more than 5 times, effectively reducing the space requirement to 1/5 or less. This creates space within the exchange for the installation of additional lines and facilities. Australia s major telecommunication carrier has accomplished the conversion of all their 2 and 8Mbit/s Digital Distribution Frames (DDF) from coaxial to twisted pair cabling using Baluns supplied by AC&E. This has achieved substantial multi-million dollar savings. It is our understanding that this carrier wishes to convert all their coaxial system within their exchanges to run on twisted pair cables for data rates covering 34, 45, 140 and 155Mbit/s, and AC&E is providing the necessary components for them to do so. AC&E is well acquainted with the technology to help any other telecommunications organisation considering the advantages of such an exercise. The maximum distances for twisted pair cables used in conjunction with the Baluns will depend on the grade of cables being used and the number of twists per unit length. Typical distances on good quality cables will be 300 metres and 160 metres respectively for 2Mbit/s and 8Mbit/s using the existing Baluns and 60 metres for 155Mbit/s with the new high speed Baluns. Benefits in Converting DDF from Coax to Twisted Pair 1. The space occupied by the DDF is reduced to one fifth, or less 2. Enables expansion without new buildings, ducting or additional space. 3. Use of smaller, low cost twisted pair cables enables easier cable routing and management. 4. Quick and easy termination of twisted pair wires saves material and labour cost. 5. High reliability of gas tight IDC contacts. 6. Full solution for migrating from old technology to new 120 structure. page 5

6 Generic Single Balun Part Numbering AC&E single Baluns identified in this catalogue conform to the part numbering standard identified on this page. Part numbers not defined generally are customer specific types. This table is useful for quickly selecting products but please request a data sheet to check all specifications and user data before purchasing products. Balun Type - Bxx Video DC to 8MHz, 75/120Ohm B00 2, 8Mbit/s, 75/120Ohm B13 2, 8, 34Mbit/s, 75/120Ohm B04 High Speed 34 to 155Mbit/s, 75/120Ohm B08 Coaxial Connector - yyy 1.6/5.6 (m) Snap Coupling /5.6 (m) Screw Coupling /5.6 (f) 003 BNC (m) 75Ohm 008 BNC (f) 75Ohm 009 BNC (f) 75Ohm Bulkhead /5.6 (m) Rt Angle Snap 025 BNC (m) 75Ohm Rt Angle 028 APT 1000 (m) Fixed Mtg with Locking Bush /2.3 (m) Straight Posi-Lock 75Ohm /2.3 (f) Bulkhead 75Ohm 044 Type 43 (f) In-line Posi-Lock 046 Type 43 (m) In-line Fixed Chassis Mtg 048 Type 43 (m) In-line Floating Chassis Mtg 049 Type 43 (m) HDC Floating Chassis Mtg 052 SMB (f) In-line 078 SMB (f) Rt Angle 085 Coax Balun IDC yyy Bxx zzz Generic Balun p/n Bxx yyy zzz Twisted Pair Connection - zzz 3 pole IDC (Krone), 0.4 to 0.65mm 010 Clam IDC for 0.5 to 0.65mm STP or UTP wire 060 Clamp IDC for 0.24 to 0.40mm STP or UTP wire 065 Clamp IDC for 0.5 to 0.65mm STP or UTP wire HDC 070 Clamp IDC for 0.24 to 0.40mm STP or UTP wire HDC 075 eg. B Balun 2,8,34Mbit/s, 1.6/5.6 (f), Clamp IDC 0.5 to 0.65 wire B Balun 2,8Mbit/s, BNC (f) 75Ohm Bulkhead, 3 pole IDC (Krone) B Balun 34 to 155Mbit/s, 1.0/2.3 (f) Bulkhead, Clamp IDC 0.3 to 0.4 wire B B B Page 6

7 Generic Balun Panel Part Numbering Balun Type - Mxx Video DC to 8MHz, 75/120Ohm 2-8Mbit/s, 75/120Ohm Mbit/s, 75/120Ohm B00 B13 B04 Generic Balun Panel p/n Mxx yyy zz pp Coaxial Connector Type - yyy 1.6/5.6 (f) 003 BNC (f) 009 Type 43 (m) In-line /2.3 (f) Bulkhead 044 SMB (m) In-line 083 Panel Matrix - zz 96 Coax and Baluns to 48 Twisted Pair Connectors Coax and Baluns to 24 Twisted Pair Connectors Coax and Baluns to 16 Twisted Pair Connectors Coax and Baluns to 2 Twisted Pair Connectors Coax and Baluns to 8 Twisted Pair Connectors 18 2 Coax and Baluns to 1 Twisted Pair Connector 21 Configuration - pp RJ45, 1 RU, 19 Rack Black, wired 1245, 2 sided RJ45, 2 RU, 19 Rack, Black, wired 1245, all connectors one side Telco connector, 2RU 19 Rack Black, fixed wiring, 2 sided R1 R6 T1 eg. M R6 M13 Balun Panel 2-8Mbit/s, 75/120Ohm, /5.6 (f) Coaxial Connectors Coaxial Connectors and Baluns to 16 twisted pair connectors R6 RJ45, 2 RU, 19 Rack, black, wired 1245, all connectors one side page 7

8 Electrical Characteristics of 2-8Mbit/s, 75/120 Balun This AC&E Telecommunication Balun is intended for 2-8Mbit/s data transmissions and features the following performance characteristics:- Exceeds ITU.G.703 performance requirements Insertion Loss: < 0.2dB (2Mbit/s); <0.3dB (8Mbit/s) Return Loss: -29dB(typ), 2Mbit/s -21dB(typ), 8Mbit/s Isolation > 250V Working temp 30 to +75 C In Mini, PCB and Standard Balun housing B13 In Balun Panel housing M13 Optimized for E1 and T1 communications Other impedances and enclosures on request 2Mbit/s pulse performance and G.703 pulse spec mask Typical return loss and G.703 minimum performance levels for 2 and 8Mbit/s transmissions. The return loss margin provides performance reserve against crushed cables, over bent cables, and other system imperfections. Electrical Characteristics of Mbit/s, 75/120 Balun This AC&E Telecommunication Balun is intended for Mbit/s, 75/120 transmissions and features the following performance characteristics:- Exceeds ITU-G.703 performance requirements Insertion Loss: < 0.3dB (8Mbit/s) Return Loss: Conforms to ITU.G.703 Isolation > 250V Working temp 20 to +75 C In Mini, PCB and Standard Balun housing B04 In Balun Panel housing type M04 Designed for E1, E2 and E3 Communications Other impedances and enclosures on request 8Mbit/s pulse performance and G.703 pulse spec mask Page 8

9 34Mbit/s pulse performance and G.703 pulse spec mask Typical return loss and G.703 minimum performance levels for 2, 8 and 34Mbit/s Electrical Characteristics of Mbit/s, 75/120 Balun The AC&E Telecommunication High Speed Balun is intended for 34 to 155Mbit/s, 75/120 transmissions. It features the following performance characteristics:- Exceeds ITU-G.703 performance requirements Insertion Loss 860KHz to 52MHz < 0.8dB 50KHz to 240MHz < 1.5dB Return Loss 1MHz to 240MHz < -15dB Isolation > 250V Working temp 30 to +75 C In Mini Balun housing type B08 Designed for E3/T3 to 155Mbit/s data streams Other impedances and housing on request 140Mbit/s pulse performance and G.703 pulse spec mask Typical return loss and ITU-G.703 minimum performance levels for 34 and 155Mbit/s transmissions. page 9

10 Standard Baluns Physical Characteristics Intended for panel mounting and can be supplied with a variety of Coaxial Connectors BNC, 1.6/5.6, Type43, BPO10 etc Twisted pair termination via 3 pole Krone IDC B Available in two speed ranges 2-8Mbit/s and Mbit/s The coaxial side is designed for DDF (1.6/5.6 connectors or similar) installation and for equipment connection (cable integral) with either male or female connectors B The mechanical endurance of the coaxial connectors is designed to give in excess of 500 connect/disconnect cycles. On the balanced side, the 120 interface connector is designed to accept termination of single and multi-strand conductors with nominal diameters from 0.4mm to 0.65mm. B The force required to terminate the IDC is designed to remain fully operative and intact after 50 connect/reconnect cycles for Krone IDC Terminals Simple cable anchorage is achievable by passing the cable through the hollow section under terminal markings. B The diagram shows the circuit symbols of the Balun with its coaxial and twisted pair connectors and the polarisation of the transformer. The Standard Balun has an earth connection taken from the outer coaxial contact to the twisted pair side and labeled E. It is optional to connect the shielding to this earth connection. B Drawing 2 and 8Mbit/s 75/120 Transmission Baluns (Identify by black coloured outer body insulation ring) Electrical Characteristics and Performance Performance exceeds ITU.G.703 The value of impedance match is 75 3 resistive to resistive, when measured from 51 to 12,672kHz with the unused end terminated into the respective resistive load. The insertion loss from both sides is < 0.2dB for 2Mbit/s and < 0.3dB for 8Mbit service. Cross talk between any two baluns mounted on a DDF strip with 15mm centres is better than -80dB in the frequency range of 0.1MHz to 12MHz. Return loss is 29dB(typ) for 2Mbit/s and 21dB(typ) for 8Mbit/s service Transmission losses for cable are excluded. Page 10

11 Black Balun Order Codes Part No Description B /N B /5.6 (m) snap to 3 pole Krone IDC 1.6/5.6 (m) screw to 3 pole Krone IDC B /5.6 (f) to 3 pole Krone IDC B /N B /5.6 (m) Rt. angle snap to 3 pole Krone IDC BNC (m) to 3 pole Krone IDC B BNC (f) to 3 pole Krone IDC B BNC (m) Rt. angle to 3 pole Krone IDC B BNC (f) bulkhead to 3 pole Krone IDC Customer Specified Black Baluns Part No Specifier Description 353/330 Telstra 1.6/5.6 (m) snap to 3 pole Krone IDC 353/644 Telstra 1.6/5.6 (m) screw to 3 pole Krone IDC 353/329 Telstra 1.6/5.6 (f) to 3 pole Krone IDC 353/518 Telstra 1.6/5.6 (m) Rt. angle snap to 3 pole Krone IDC 353/693 Telstra BNC (m) to 3 pole Krone IDC 353/610 Telstra BNC (m) Rt. angle to 3 pole Krone IDC 2, 8 and 34Mbit/s 75/120 Transmission Baluns Identifiable by its outer body insulating ring which is coloured white. Electrical characteristics and performance The value of the impedance match is 75 ± 10 resistive to 120 ± 12 resistive, when measured at 1 to 17MHz and with the unused end terminated into the respective resistive load. The insertion loss less than 0.9dB is in the range 0.2MHz to 70MHz from both sides. Cross talk between any two baluns mounted on a DDF strip is better than -60dB with vertical orientation of IDC connectors in the range of 1MHz to 70MHz Return loss is better than -15dB in the frequency range of 1MHz to 70MHz in both directions of transmission conforming to ITU-G.703. Transmission losses for cable are excluded Mbit/s Standard Balun Order Codes Part No Description B /L 1.6/5.6 (m) snap to 3 pole Krone IDC B /L 1.6/5.6 (m) screw to 3 pole Krone IDC B /L 1.6/5.6 (f) to 3 pole Krone IDC B /L 1.6/5.6 (m) Rt. angle snap to 3 pole Krone IDC B /L BNC (m) to 3 pole Krone IDC B /L BNC (f) In-line to 3 pole Krone IDC B /L BNC (m) Rt. angle to 3 pole Krone IDC B /L BNC (f) bulkhead to 3 pole Krone IDC Customer Codes for Mbit/s Baluns Part No Specifier Description 353/867 Telstra 1.6/5.6 (m) snap to 3 pole Krone IDC 353/875 Telstra 1.6/5.6 (m) screw to 3 pole Krone IDC 353/566 Telstra 1.6/5.6 (f) to 3 pole Krone IDC 353/873 Telstra 1.6/5.6 (m) Rt. angle snap to 3 pole Krone IDC 353/876 Telstra BNC (m) to 3 pole Krone IDC 353/874 Telstra BNC (m) Rt. angle to 3 pole Krone IDC page 11

12 Standard Balun Termination Procedure 1. Mount the balun to the panel (if applicable). 2. Strip the cable sheath to expose the individual twisted pairs (if applicable) 3. Pass the desired twisted pair through the cable restraint hole in the moulding entering at A 4. Loop the wires back over and into the appropriate slot in the IDC connector. 5. The IDC marked A corresponds with the centre contact in the coax connector, B corresponds to the outer contact and E earth. 6. Terminate the IDC using a Krone terminating tool. 7. Dress the cables as shown in the diagram below, allowing a loop of about 25mm at the cable entry in case the wires need to be re-terminated. APPROX. 25mm TWISTED PAIR ENTERS THE HOLE AT THE END OF THE CABLE RESTRAINT AND LOOPS BACK OVER THE BLOCK INTO THE IDC MULTI PAIR CABLE Typical 1DME application of Balun replacing coaxial connectors TJ1 Part No. KR TJ1 Description IDC Connection tool Standard Balun Termination Jig (for termination of unmounted 1.6/5.6 only) Page 12

13 Mini Balun Series Mini Baluns are ideal in applications where size and space are restricted due to their small dimensions. They are intended for panel or cable mounting and feature AC&E s clamp IDC termination allowing installation without special tools. They are fully shielded and offer EMC compatibility and EMI compliance as well as excellent high data rate performance. They are available in three speed ranges, 2-8Mbit/s, Mbit/s or 34 to 155Mbit/s. B The Mini Balun is the subject of a number of patent applications. Mini Baluns offer the following performance features:- Fully shielded Three speed ranges, 2-8Mbit/s, Mbit/s or 34 to 155Mbit/s. Electrical Characteristics on pages 8 and 9 EMC and RFI Compliant B Contacts Plated min. 1.25µm Ni + min. 1.25µm Au Coax Connectors with BeCu spring contacts and Teflon Insulators Coaxial Connector Insertion cycles > 500 IDC Contacts Phosphor Bronze IDC Insertion Cycles > 20 IDC to suit 0.24 to 0.40mm Cu wire (p/n ends 5 ) AWG IDC to suit 0.50 to 0.65mm Cu wire (p/n ends 0 )AWG Body Parts Plated Min. 5µm Ni Cable anchorage via channeled stress-relief around stuffer cap B B B Mini Balun 2-8Mbit/s, 75/120 Balun (Identify by black coloured IDC former) Order Codes Part Number Description B /5.6 (m) Straight Snap Coupling B /5.6 (m) Straight Screw Coupling B /5.6 (f) Straight Bulkhead B BNC (m) Straight B BNC (f) Straight Bulkhead B /2.3 (m) Straight Posi-lock Coupling B /2.3 (f) Straight Bulkhead B Type 43 (f) Straight Posi-lock Coupling B Type 43 (m) Straight Bulkhead Fixed Mounting B Type 43 (m) Straight Bulkhead Floating Mounting B Type 43 HDC (m) Straight Floating Mounting B SMB (f) In-line Coupling B SMB (f) Rt. Angle Coupling (0.50 to 0.65mm wire types listed, for 0.24 to 0.40 wire p/n last digit 0 becomes 5 ) page 13

14 Customer Codes for 2-8Mbit/s Mini Baluns Part No Specifier Description NTUM98LA Nortel Mini Balun Pair, 1.6/5.6 (m) Straight Screw Coupling NTQG41GA Nortel Mini Balun Pair, BNC (m) Straight NTUM 98YA Nortel Mini Balun Pair, Type 43 (m) Str Bulkhead Floating Mounting /196 Marconi Mini Balun, 1.0/2.3 (m) Straight Posi-Lock Coupling Marconi Type 43 (m) Straight Bulkhead Floating Mounting Marconi Type 43 HDC (m) Str Bulkhead Floating Mounting CS Nokia 1.0/2.3 (f) Straight Bulkhead CS Nokia BNC (M) Straight Mini Balun Mbit/s, 75/120 Balun (Identify by fawn coloured IDC former) Order Codes Part Number Description B /5.6 (m) Straight Snap Coupling B /5.6 (m) Straight Screw Coupling B /5.6 (f) Straight Bulkhead B BNC (m) Straight B BNC (f) Straight Bulkhead B /2.3 (m) Straight Posi-lock Coupling B /2.3 (f) Straight Bulkhead B Type 43 (f) Straight Posi-lock Coupling B Type 43 (m) Straight Bulkhead Fixed Mounting B Type 43 (m) Straight Bulkhead Floating Mounting B Type 43 HDC (m) Str Bulkhead Floating Mounting (0.32 (0.24 to 0.40mm wire types listed, for 0.50 to wire p/n last digit ë5í '5' becomes '0') ë0í) Customer Codes Part No Specifier Description Lucent 1.6/5.6 (m) Straight Screw Coupling Lucent 1.6/5.6 (f) Straight Bulkhead Lucent BNC (m) Straight Lucent BNC (f) Straight Bulkhead Mounting Lucent APT 1000 (m) StrBulkhead Fixed Mtg with Locking Bush Lucent 1.0/2.3 (m) Straight Posi-lock Coupling Lucent 1.0/2.3 (f) Straight Bulkhead Lucent Type 43 (f) Straight Posi-lock Coupling Lucent Type 43 (m) Straight Bulkhead Fixed Mounting Lucent 1.6/5.6 (f) Monitored Balun U Link 20dB Lucent Type 43 (m) Straight Bulkhead Floating Mounting Lucent Type 43 HDC (m) Straight Bulkhead Floating Mount High Speed Mini Balun 34 to 155Mbit/s, 75/120 Balun (Identify by knurled body) Order Codes Part No. Description B /5.6 (m) Straight Screw Coupling B /5.6 (f) Straight Bulkhead B BNC (m) Straight B BNC (f) Straight Bulkhead B /2.3 (m) Straight Posi-lock Coupling B B /2.3 (f) Straight Bulkhead B Type 43 (f) Straight Posi-lock Coupling B Type 43 (m) HDC Straight Floating Mounting (0.32 (0.24 to 0.40mm wire types listed, for 0.50 to wire p/n last digit ë5í '5' becomes '0') ë0í) Page 14

15 Mini-Balun Termination Procedure Cable examples IDC 26-28AWG Filotex ET2PBB010 (8 pair or similar) or Lucent Technologies IDC 22-24AWG Belden JPMD06AAH Dis-assemble the rear end components from the mini-balun. 2. Fit the nut and outer cover onto the cable in that order. A B 3. Strip the cable jacket to B from the end of the cable. Cut the drain wire and foil A from the end of the cable. 4. Flare the foil and fold it and the drain wire back over the sheath. Fit the grounding ring over the end of the cable. 5. Insert the wires into the holes in the small end of the stuffer cap marked A and B. 6. The A connection corresponds with the polarity of the centre conductor of the coax. Push the stuffer cap hard against the washer. Spread the conductors apart towards the sides of the stuffer cap and fit the conductor ends into the slot in each side of the stuffer cap. 7. Ensure that the end of each conductor is positioned behind the lip and into the cavity at the end of the slot, as per illustration. 8. Fold the foil and the drain wire back over the outside of the stuffer cap. Ensure the drain wire ends within the tapered section of stuffer cap. 9. Orient the tongue on the mini-balun to line up with the flat on the stuffer cap and insert the stuffer cap onto the IDC terminals. Ensure that the wires are correctly positioned in the slots (Refer to 7 above). 10. Pull the rear outer body forward and align the flat to the tongue in the Mini-Balun body. Secure the retaining nut finger tight. Lightly tighten using the spanners recommended. page 15

16 Dual Balun This module contains 2 Coaxial Connectors, 2 Baluns and 1 RJ45 socket housed in an insulated enclosure. It is intended to convert an E1/T1 Channel consisting of 1 Transmit and 1 Receive signal from 75Ω coaxial to 2 x 120Ω twisted pair signals on an RJ45/Cat5 cable. This module features:- Fully shielded Circuitry Complies with EMC requirements. Insertion loss: < 0.4dB Return Loss: < -25dB Interfaces two coaxial "E1", 2Mbit/s paths into an RJ45 socket Specified for 2-8Mbit/s use Other connectors available on request, e.g. SMB Provides 250V isolation from input to output terminals Insulated enclosures (BNC 37x37x28mm, Others 31x57x61mm) Matching impedances 75 to 120. Others on request Mbit/s versions available on request M R2 3 Order Codes M R2 M R2 M R2 M R2 Dual Balun, 2x BNC (f) to RJ45, 2 to 8Mbit/s, 75/120 Ω Dual Balun, 2x 1.6/5.6 (f) to RJ45, 2 to 8Mbit/s, 75 /120 Ω Dual Balun, 2x BT43 (m) to RJ45, 2 to 8Mbit/s, 75 /120 Ω Dual Balun, 2x 1.0/2.3 (f) to RJ45, 2 to 8Mbit/s, 75 /120 Ω Customer Order Codes Lucent Dual Balun, 2x BNC (f) to RJ45, 2 to 8Mbit/s, 75/120 Ω A Nortel Dual Balun, 2x BNC (f) to RJ45, 2 to 8Mbit/s, 75/120 Ω High Speed Dual Balun 34 to 155Mbit/s This module offers two STM1 155Mbit/s paths (also 140Mbit/s, 45Mbit/s or 34Mbit/s) into a single RJ45 socket from coaxial feeders. The module contains 2 Coaxial Connectors, 2 Baluns and 1 RJ45 socket housed in an insulated enclosure. The Dual Balun module features:- Fully shielded Circuitry Insertion loss: < 0.8dB Return Loss: < -15dB from 1MHz to 240MHz and B < -18dB from 8.4MHz to 12.6MHz Cross Talk: < -80dB from 51KHz to 3.072MHz Pulse Shape: Meets ITU G.703 Mask at 34 and 155Mbit/s ESD Immunity Tests: Passed EN EMC: Complies with Class B limits of EN with STP Cable Provides 1kV isolation from input to output terminals. Stable over the working temperature of -30ºC to 55ºC Housed in insulated wall mountable enclosures (31x57x61mm). Matching impedances 75 to 120Ω. Others on request. Earthing is available in a number of combinations to suit most applications. As standard, a capacitor is arranged to connect the grounding of the co-axial to twisted pair and a zero ohm resistor ties the grounding of both coaxial connectors. Page 16

17 PCB Baluns Order Codes A selection of Part AC&E No Baluns are available Description housed in PCB mounting right angle coaxial B connectors. 072 Dual Balun, 2x BNC (f) to RJ45, 34 to 155Mbit/s, 75/120Ω B Dual Balun, 2x 1.6/5.6 (f) to RJ45, 34 to 155Mbit/s, 75/120Ω These products are intended for use by transmission equipment B Dual Balun, 2x BT43 (m) to RJ45, 34 to 155Mbit/s, 75/120Ω designers who wish to take advantage of the space savings that an B Dual Balun, 2x 1.0/2.3 (f) to RJ45, 34 to 155Mbit/s, 75/120Ω integrated Connector/Balun provides. Available in BNC, 1.6/5.6 and BT43 these PCB Baluns feature a Dual winding Balun isolation Cables of 250V and are available with a 2-8Mbit/s, Transmission Balun core. Other coaxial connectors and AC&E's impedances Dual on Balun request. Cables provide the ideal connectivity and interface solution where space is at a premium as they provide a solution with or without a patch panel. Factory assembled Mini The AC&E Balun PCB Cable Baluns assemblies offer the are following supplied performance to features:- length as requested. Fully shielded Dual Balun Available Cables in BNC, Feature: 1.6/5.6 and BT43 coaxial connectors Common PCB footprint DetaiIed Compact electrical panel less characteristics interface solution on pages 8 and 9 Fully shielded interconnect 2-8Mbit/s Transmission Balun Exceeds G.703 specified performance 75/120 All Mini impedance Baluns supported transformation Small Supplied size and with rugged cable boots construction for additional strain relief Other Catalogue Coaxial types Connectors available and from impedances stock on request Cables labeled TX & RX Mbit/s Transmission or Video Balun core on request Order Code (xx=length in metres) Part Number Description S440/xxM 1.6/5.6 (f) x 2 to RJ45 (m) shielded on STP S539/xxM 1.6/5.6 (m) screw x 2 to RJ45 (m) shielded on STP S441/xxM 1.0/2.3 (f) x 2 to RJ45 (m) shielded on STP Order S540/xxM Codes Part S442/xxM No 1.0/2.3 (m) x 2 to RJ45 (m) shielded on STP BNC (f) Description x 2 to RJ45 (m) shielded on STP B13 S541/xxM BNC (m) PCB x 2 to Balun, RJ45 BNC (m) shielded (f), 2-8Mbit/s, on STP 75/120 B13 S542/xxM T43 (f) Posi PCB lock Balun, x 21.6/5.6 to RJ45 (f), (m) 2-8Mbit/s, shielded 75/120 on STP B13 S543/xxM T43 (m) PCB Fixed Balun, mounting BT43 to (m), RJ45 2-8Mbit/s, (m) shielded 75/120 on STP S554/xxM BT43 (m) x 2 to RJ45 (m) shielded on STP S557/xxM BT43 (m) HDC x 2 to RJ45 (m) shielded on STP page 17

18 Dual Balun Balun Panels This AC&E's module range contains of Balun 2 Coaxial panels are Connectors, intended 2 for Baluns and 1 RJ45 socket converting housed 75Ω in coaxial an insulated transmissions enclosure. to It is 120Ω intended to convert an E1/T1 balanced Channel twisted consisting pair signals. of 1 They Transmit are based and 1 on Receive signal from 75 AC&E's coaxial Mini to 2 Balun x 120 technology twisted pair which signals is on the an RJ45/Cat5 cable. subject of a number of patent applications. A common application is when new equipment This designed module with features:- twisted pair interfaces needs to be connected Fully shielded to an established Circuitry coaxial environment. B AC&E's Balun Panels achieve such an interface Complies with EMC requirements. with a minimum of electrical degradation and exceed Insertion ITU-G703 loss: for < 0.4dB 2-8Mbit/s transmissions (2-8-34Mbit/s Return types Loss: available < -25dB on request). Together with matching Patch Panels, Patch Interfaces two coaxial E1, 2Mbit/s paths into an RJ45 socket Cables, U Links and Connectors AC&E offer a Complete Specified Connectivity for 2-8Mbit/s and use Interface Solution. Other connectors available on request, e.g. SMB The Provides extensive 250V range isolation of panels from input is available to output on terminals short leadtime and features:- 19" Rack Mounted Balun Panels Insulated enclosures (BNC 37x37x28mm, Others 31x57x61mm) Up Matching to 96 baluns impedances in 1RU 75 panel to 120. height Others offers on mechanical request. limit packing density Mbit/s density varients versions and available 6 configurations request available from stock range Stocked types include BNC, 1.6/5.6, BT43, SMB and 1.0/2.3 coaxial connectors (others on request) Electrical Order Characteristics Codes on page 8 B Dual Balun, 2x BNC (f) to RJ45, 2-8Mbit/s, 75/120 Shielded construction gives excellent EMC performance B Dual Balun, 2x 1.6/5.6 (f) to RJ45, 2-8Mbit/s, 75/120 Internal B04 shielding gives low Dual adacent Balun, channel 2x BT43 cross (m) to talk RJ45, < -80dB 2-8Mbit/s, 75/120 Ultra thin B04 panel design (96 balun Dual Balun, 45mm, 2x others 1.0/2.3 33mm) (f) to RJ45, leaves 2-8Mbit/s, more 75/120 room for cable entry Reversable panel allows coaxial or RJ45 side to be mounted to the front Adjustable panel recess gives more cable entry space where required High Speed Dual Balun 34 to 155Mbit/s Zinc sealed, powder coated steel for rigidity and long life Mounting brackets may be substituted to support other standards This module offers two STM1 155Mbit/s paths (also Matching Patch Panels and Blank Panels for a Complete Connectivity and Interface 140Mbit/s, 45Mbit/s or 34Mbit/s) into a single RJ45 Solution socket from coaxial feeders. The module contains 2 Coaxial Connectors, 2 Baluns and 1 RJ45 socket housed in an insulated enclosure. Ultra High Density Balun Panel 96 Coax to 48 RJ45, 1RU, 75/120Ω The Dual Balun module features:- Fully shielded Circuitry Insertion loss: < 0.8dB Return Loss: < -15dB from 1MHz to 240MHz and < -18dB from 8.4MHz to 12.6MHz B Cross Talk: < -80dB from 51KHz to 3.072MHz Pulse Shape: Meets ITU G.703 Mask at 34 and 155Mbit/s ESD Immunity Tests: Passed EN EMC: Complies with Class B limits of EN with STP Cable Provides 1kV isolation from input to output terminals. Order Stable codes over the working temperature of -30 C to 55 C M13 Housed R1 in insulated BT43 (m) wall to RJ45, mountable 96x48, enclosures 1RU, 75/120Ω (31x57x61mm)., 2-8Mbit/s M13 Matching R1 impedances 1.0/2.3 (f) to 75 RJ45, to x48, Others 1RU, 75/120Ω, on request. 2-8Mbit/s M13 Earthing R1 is available SMB(m) to in RJ45, a number 96x48, 1RU, of combinations 75/120Ω, 2-8Mbit/s to suit most applications. As standard, a capacitor is arranged to connect the grounding of the co-axial to twisted pair and a zero ohm resistor ties the grounding of both coaxial connectors. Page 18

19 High Density Balun Panel 48 Coax to 24 RJ45, 1RU, 75/120 Order Codes Part No B B B B Description Dual Balun, 2x BNC (f) to RJ45, 34 to 155Mbit/s, 75/120 Dual Balun, 2x 1.6/5.6 (f) to RJ45, 34 to 155Mbit/s, 75/120 Dual Balun, 2x BT43 (m) to RJ45, 34 to 155Mbit/s, 75/120 Dual Balun, 2x 1.0/2.3 (f) to RJ45, 34 to 155Mbit/s, 75/120 Dual Balun Cables AC&E s Dual Balun Cables provide the ideal connectivity and interface solution where space is Order at a codes premium as they provide a solution with or M13 without a R1 patch BNC panel. (f) to RJ45, Factory 48x24, assembled 1RU, 75/120, 2-8Mbit/s Mini M Balun 44 R1 Cable 1.6/5.6 assemblies (f) to RJ45, are 48x24, supplied 1RU, to 75/120, 2-8Mbit/s length M as 44 requested. R1 BT43 (m) to RJ45, 48x24, 1RU, 75/120, 2-8Mbit/s M R1 1.0/2.3 (f) to RJ45, 48x24, 1RU, 75/120, 2-8Mbit/s Dual Balun Cables Feature: S440/5M Compact panel less interface solution Fully shielded interconnect Exceeds G.703 specified performance All Mini Baluns supported Supplied with cable boots for additional strain relief Catalogue types available from stock Cables labeled TX & RX Medium Density Balun Panel 32 Coax to 16 RJ45, 1RU, 75/120 Order Code (xx=length in metres) Part Number Description S440/xxM 1.6/5.6 (f) x 2 to RJ45 (m) shielded on STP S539/xxM 1.6/5.6 (m) screw x 2 to RJ45 (m) shielded on STP Order codes S441/xxM 1.0/2.3 (f) x 2 to RJ45 (m) shielded on STP M S540/xxM 36 R1 BNC (f) 1.0/2.3 to RJ45, (m) 32x16, x 2 to 1RU, RJ45 75/120, (m) shielded 2-8Mbit/s on STP M S442/xxM 36 R1 1.6/5.6 (f) BNC to RJ45, (f) x 232x16, to RJ45 1RU, (m) shielded 75/120, on 2-8Mbit/s STP M S541/xxM 36 R1 BT43 (m) BNC to RJ45, (m) x 32x16, 2 to RJ45 1RU, (m) 75/120, shielded 2-8Mbit/s on STP M S542/xxM 36 R1 1.0/2.3 (f) T43 to (f) RJ45, Posi 32x16, lock x 1RU, 2 to RJ45 75/120, (m) shielded 2-8Mbit/s on STP S543/xxM T43 (m) Fixed mounting to RJ45 (m) shielded on STP Single Sided Balun Panel 32 Coax to 16 RJ45, 2RU, 75/120 Order codes M R6 M R6 M R6 M R6 BNC (f) to RJ45, 32x16, 2RU, 75/120, 2-8Mbit/s 1.6/5.6 (f) to RJ45, 32x16, 2RU, 75/120, 2-8Mbit/s BT43 (m) to RJ45, 32x16, 2RU, 75/120, 2-8Mbit/s 1.0/2.3 (f) to RJ45, 32x16, 2RU, 75/120, 2-8Mbit/s page 19

20 Broadband Telco Connector Distribution Balun Panel System 32 Coax to 2x50way Telco, 1 RU, 75/120 Home As modern technology is becoming integral with our lives, many people require a multi-function outlet in almost every room in their house. Along with the existing Alarm, Radio, Telephone, analog and ISDN Computer outlets, you can now with the AC&E Broadband Distribution System, also bring TV Order or Video Codes to one or every room in your home. This is achieved M by T1 using BNC a (f) balun to 2x50way cable Telco, connected 1RU, 75/120, to the 2-8Mbit/s Cat5e M or Cat6 32 T1 wall 1.6/5.6 outlet in (f) each to 2x50way room. Telco, 1RU, 75/120, 2-8Mbit/s There M is 32 no T1 longer BT43 a need (m) to for 2x50way duplication Telco, 1RU, of cables. 75/120, 2-8Mbit/s With M13 the 044 AC&E 32 T1 Broadband 1.0/2.3 (f) Distribution to 2x50way Telco, System, 1RU, you 75/120, can 2-8Mbit/s now easily change your wall-outlet from a socket for Tele-work to a TV socket. Low Density Balun Panel 16 Coax to 8 RJ45, 1RU, 75/120 Office Why install a costly coaxial TV cable into an existing premises, when many buildings already have many twisted pair cables installed for varying applications? Using the AC&E Broadband Distribution System, TV signals can now be distributed economically over twisted pair cable. Installation of the AC&E Broadband Distribution System is straight forward as the system is designed Order Codes to fit readily into either a standard 10 or 19 M R1 BNC (f) to RJ45, 16x8, 1RU, 75/120, 2-8Mbit/s equipment racks where many of the twisted pair ends M R1 1.6/5.6 (f) to RJ45, 16x8, 1RU, 75/120, 2-8Mbit/s are already terminated. Simple RJ45 patch cords are M R1 BT43 (m) to RJ45, 16x8, 1RU, 75/120, 2-8Mbit/s used M to patch 18 R1 the 1.0/2.3 two systems (f) to RJ45, together. 16x8, 1RU, The 75/120, system 2-8Mbit/s can handle up to Channel 69 (European Standard). Additionally AC&E Broadband Balun patch cords are required when only an unbalanced input facility is available on the TV set (PAL coaxial connector). Single Sided Balun Panel 16 Coax to 8 RJ45, single sided, 2RU, 75/120 Order Code Part No Description VDS001 Broadband Distribution System with 4 outlets, 10 panel * VDS002 Broadband Distribution System with 8 outlets, 10 panel * VDS003 Broadband Distribution System with 4 outlets, 19 panel Order Codes VDS004 Broadband Distribution System with 8 outlets, 19 panel M VDPC01/2M R6 BNC (f) to Broadband RJ45, 1 Side, Balun 2 RU, patch 75/120, cord, 2m, 2-8Mbit/s PAL(m) to RJ45 UTP M VDPC02/2M R6 1.6/5.6 (f) to Broadband RJ45, 1 Side, Balun 2 patch RU, 75/120, cord, 2m 2-8Mbit/s PAL (m) to RJ45 STP M VDSTERM R6 BT43 (m) to RJ45, Terminator 1 Side, 2 RU, 75/120, 2-8Mbit/s M *10 R6 panel 1.0/2.3 made according (f) to RJ45, to Krone 1Side, cabinet 2 RU, sizes. 75/120, Other Mbit/s sizes on request. Page 20

21 Patch Panel Solutions AC&E s range of matching Patch Panels complements the AC&E range of Balun panels thus providing interconnect solution that is highly functional and professional in appearance. Constructed in zinc sealed, black powder coated steel they are built for long life. The Baluns, U Links, Through Adaptors and Patch Cables listed on this page have been designed with compatibility in mind and are intended to be used in and on the patch panels listed here to provide a complete connectivity and interface solution. Select your coaxial connectors from AC&E s range of BNC, 1.6/5.6, BT43 and 1.0/2.3 listed on the web for your total requirement. STUDY Blank Panels BEDROOM BEDROOM Order Codes - Blank Panels Part No. Description Concealed Wiring JS1 Blank JS4 Blank Blank Panel, 1 RU, 19, black powder coated steel Blank Panel, 2 RU, 19, black powder coated steel 10 RACK MOUNTING MODULE BNC Panels & Accessories LIVING AREA KITCHEN Order Codes - BNC Panels JS7/40 BNCU BROADBAND DISTRIBUTION SYSTEM JS3/20 BNCU Order Codes - BNC Panel Accessories Specification: Balun Select Part any Number BNC Standard VDS001, or Mini VDS002 from this catalogue Power A Input U Link 5.5 BNC Watt (m) 50 - BNC and 60Hz (m) 230V Input S267/1M Connection Patch F-type Cable female BNC (m) - BNC (m) 1m length A BNC (f)-bnc (f) through adaptor (push on), insulated Output Connection 4 x RJ45 sockets (VDS001), 8 x RJ45 sockets (VDS002) AC1291 BNC (f)-bnc (f) through adaptor (bayonet), insulated Frequency Range 47 to 862MHz Gain and Equalisation Set for +2dB system gain with 30m typical Cat5e cable Size BNC panel, 2 x 20, 2 RU, black powder coated steel, empty BNC panel, 1 x 20, 1 RU black powder coated steel, empty 1.6/5.6 Panels & Accessories 88 (2RU) x 254 x 185 (HxWxD) Typical Order Codes Cable Lengths: 1.6/5.6 Panels Cat. JS3/48 5e 1656U 1.6/5.6 40m* Panel, 2x24, 1 RU, black powder coated steel, empty, 15mm pitch Cat. JS3P/ U 1.6/5.6 45m* Panel, 2x24, 1 RU, grey fibre reinforced plastic, empty, 15mm pitch *Distance Order Codes depends - 1.6/5.6 on the Panel input Accessories signal strength and the transmission characteristics of the cable used. A Through Adaptor 1.6/5.6 (f) to 1.6/5.6 (f), uninsulated Balun Select any 1.6/5.6 Standard or Mini Balun from this catalogue A001702/15/1/N U Link 1.6/5.6 (m) - 1.6/5.6 (m) screw coupling, 15mm pitch A001716/15/2/N U Link monitor Snap coupling rear entry monitor (f) 26db 15mm pitch A001716/15/1/N U Link monitor Screw coupling rear entry monitor (f) 26db 15mm pitch A001717/15/2/N U Link BROADBAND monitor Snap RJ45coupling side TWISTED entry PAIR monitor (f) 26db RJ45 15mm pitch BROADBAND COAXIAL CABLE AM PLIFIER BALUN WALL CAT 5e / 6 BALUN S250/1M/N Patch cable 1.6/5.6 (m) - 1.6/5.6 (m), length 1m SOCKET Customised Requirements WALL SOCKET Specification subject to change without notice. This product is supplied for evaluation and has yet to undergo approvals testing. CABLE SINGLE CHANNEL APPLICATION Should you have a requirement for a customized Patch Panel, U Link, Balun or Cable please us at connect@acande.com with your requirement. page 21

22 Customised Balun Assemblies Balun Panels Following are examples of customer specific products that we have produced on request to solve AC&E s specific range interface of Balun needs. panels You too are intended can have for your specific needs addressed by AC&E, by converting specifying your 75 own coaxial requirements. transmissions Contact to us 120 by phone, fax or web to discuss your requirements. balanced twisted pair signals. They are based on Quad AC&E s Channel Mini Balun Balun technology Assembly which is the Order subject Code: of a number B of 074 patent Customer: applications. Nokia A common application is when new equipment Description: designed with twisted pair interfaces needs to be This connected Quad to Channel an established Balun assembly coaxial environment. has been developed for a major AC&E s Balun Worldwide Panels achieve Telecommunication such an interface Equipment Manufacturer/Solutions with a minimum of electrical Provider. degradation The product and features miniature exceed ITU-G703 connectors for 2-8Mbit/s (4x Type transmissions SMB) and an (2- RJ45 socket. This 8-34Mbit/s package types is available extremely on small request). and is capable of handling four Together channels with at matching E1 (2.048Mbit/s) Patch Panels, or T1 (1.544Mbit/s) Patch rates and Cables, has an U Links isolation and voltage Connectors rating of AC&E 1.5KV offer DC. a Complete Connectivity and Interface Solution. Features: B The extensive range of panels is available on short leadtime and features:- 19 Rack Mounted Balun Panels The size is small for the purpose of converting 4 coaxial transmission paths into one single RJ45 socket and packaging Up to 96 baluns these in functions 1RU panel into height a volume offers mechanical of 31 x 33 limit x packing density 43mm. 5 density varients and 6 configurations available from stock range Various Stocked combinations types include of BNC, coaxial 1.6/5.6, connector BT43, SMB types and can 1.0/2.3 be coaxial connectors (others on request) incorporated into this design such as 1.6/5.6, Type 43, BNC, Electrical 1.0/2.3 Characteristics and other variations page 8 of connector types can be Shielded accommodated construction (size gives adjustment excellent is EMC necessary performance to suit size Internal of coaxial shielding connectors) gives low upon adacent request. channel cross talk < -80dB Corporate labeling can be arranged to suit major customer requirements. In addition, for the Ultra thin panel design (96 balun 45mm, others 33mm) leaves more room for cable entry purpose of technician labeling an area for felt pen marking is provided. Low Reversable losses. Insertion panel allows Loss: coaxial < 0.5dB or and RJ45 Return side to Loss: be mounted better than to the 20dB. front Adjustable panel recess gives more cable entry space where required Zinc sealed, powder coated steel for rigidity and long life Mounting brackets may be substituted to support other standards Connector, Integral Balun Pair Order Matching Code: B04 Patch 023 Panels 024 and Customer: Blank Panels Telstra for Australia a Complete Connectivity and Interface Solution Description: Connector, Integral Balun Pair, (for Ericsson ISDN PRA Interface) Ultra High Density Balun Panel 96 Coax to 48 RJ45, 1RU, 75/120 B Features: Allows unbalanced coaxial type 75 equipment to simply connect to 120 shielded twisted pair. It provides interfacing to two separate circuits (a go and come path). Avoid more costly and space consuming 75 hardware for patching at the distribution frame. Minimal losses and distortion - refer Black Balun characteristics. (refer page 10). Low cost and optimal size form a simple design with minimal component count, being integral with existing connectors typically used in ISDN Interface Cards on AXE Systems. Electrically shielded between adjacent circuit. Cross Talk Performance (Isolation): Order codes Adjacent Balun near End Cross Talk is better than 35dB up to 34MHz and better than 28dB up M13 to MHz. 98 R1 BT43 (m) to RJ45, 96x48, 1RU, 75/120, 2-8Mbit/s M13 Other electrical R1 1.0/2.3 parameters (f) to RJ45, - refer 96x48, Standard 1RU, 75/120, 2-8Mbit/s 2-8Mbit/s Balun in this catalogue. Page 22

23 DB9 to Coaxial Connector High Order code: Density B Balun 054 DB9(m) Panel to 1.6/ Coax (f) to 24 Customer: RJ45, 1RU, Lucent 75/120 B DB9(m) to Type 43 (m) Customer: Lucent Description: A simple solution to the problem of converting a 2Mbit/s (E1) signal from twisted pair 120 to coaxial 75 in one compact adaptor. This device has shielding compliant with EMC requirements and transmission performance to ITU-T G.703 requirements. This is a typical cost effective solution for transferring a clock signal DB9 to Coaxial Baluns from Order one codes network to another. M R1 BNC (f) to RJ45, 48x24, 1RU, 75/120, 2-8Mbit/s Features: M R1 1.6/5.6 (f) to RJ45, 48x24, 1RU, 75/120, 2-8Mbit/s M R1 BT43 (m) to RJ45, 48x24, 1RU, 75/120, 2-8Mbit/s Bit rates of 2 and 8Mbit/s M R1 1.0/2.3 (f) to RJ45, 48x24, 1RU, 75/120, 2-8Mbit/s High speed Bit rates, 34 to 155Mbit/s on request. Low insertion loss figures together with good return loss performance and meets the mask performance of ITU-Telecommunication G.703. (refer to mini-balun electrical performance). Gives low cross-talk and excellent EMC performance. Medium Adaptable Density to other coaxial Balun connectors. Panel eg: BNC, 32 SMA/B/C, Coax to 161.0/2.3 RJ45, etc. 1RU, 75/120 Designed for Impedance Matching typically 50 or 75 to 100 or 120 or 150. Cost effective high reliability product with good surge performance ITU-T K x E1 Transmission Path Interface Module Order Code: K125 Customer: Nortel Description: Panel assembly containing 16 x Type 43 male connectors and having 75/120 Mini Baluns then Order connecting codes to Male D Sub Connector (44 pin). M R1 BNC (f) to RJ45, 32x16, 1RU, 75/120, 2-8Mbit/s M R1 1.6/5.6 (f) to RJ45, 32x16, 1RU, 75/120, 2-8Mbit/s The assembly was designed to work at 2Mbit/s and M complying 36 R1 BT43 with (m) to International RJ45, 32x16, 1RU, EMC 75/120, 2-8Mbit/s requirements. M R1 It 1.0/2.3 was custom (f) RJ45, built 32x16, to suit 1RU, a 75/120, 2-8Mbit/s defined volume within a modern UTMS System. Single Sided Balun Panel 32 Coax to 16 RJ45, 2RU, 75/120 Features: Allows for earthing options for and paths. Identification strip which allows labelling of each transmission path. A handle is provided on the assembly to allow it to be installed in a confined space as well as provision for sealing the assembly within the System so that minimum exposure of the cables is provided. The frame is only 155 x 45mm and 75mm deep. Refer to mini-baluns for mechanical and electrical detail Order codes M R6 M R6 M R6 M R6 BNC (f) to RJ45, 32x16, 2RU, 75/120, 2-8Mbit/s 1.6/5.6 (f) to RJ45, 32x16, 2RU, 75/120, 2-8Mbit/s BT43 (m) to RJ45, 32x16, 2RU, 75/120, 2-8Mbit/s 1.0/2.3 (f) to RJ45, 32x16, 2RU, 75/120, 2-8Mbit/s page 23

24 Telco Balun Connector Cable Assemblies Balun Panel 32 Coax to 2x50way Telco, 1 RU, 75/120 Order Codes M T1 BNC (f) to 2x50way Telco, 1RU, 75/120, 2-8Mbit/s M T1 1.6/5.6 (f) to 2x50way Telco, 1RU, 75/120, 2-8Mbit/s M T1 BT43 (m) to 2x50way Telco, 1RU, 75/120, 2-8Mbit/s M T1 1.0/2.3 (f) to 2x50way Telco, 1RU, 75/120, 2-8Mbit/s Description: A range of Balun Cable Assemblies are available with your selection of connector types at either ends. Nominal Impedance ratios of 75 to 120 and bit rates are selectable from the Mini-baluns Low shown on Density page 13 of Balun this handbook. Panel On 16 the Coax balanced to 8 RJ45, side 1RU, a selection 75/120 of single or multiconnectors are available with various forms of mounting and/or shielding. The cable selection is arranged in Characteristic Impedances and/or shielding cost benefits. Coaxial Side (with Mini-balun) Cable Types Twisted Pair Side Type /5.6 Recommended for Minibaluns. (CBTP26301) RJ45 Plug (shielded or non-shielded) 1.0/2.3 UTP, Cat.5e or Cat.6 DB9 to 37 for plug or socket BNC STP, Cat 5 Bantam Plugs Customised Customised Customised Optional cable labels and cable stress relief attachments are available Order Codes Examples: M R1 BNC (f) to RJ45, 16x8, 1RU, 75/120, 2-8Mbit/s M R1 1.6/5.6 (f) to RJ45, 16x8, 1RU, 75/120, 2-8Mbit/s Pt M13 No 049 S281/3M 18 R1 using BT43 B04 (m) 001 to RJ45, 06516x8, to 1RU, 75/120, Pt 2-8Mbit/s No S440/1M using 2 x B to Krone 4P on CBTP26301 RJ45 on STP Cat 5 M R1 1.0/2.3 (f) to RJ45, 16x8, 1RU, 75/120, 2-8Mbit/s Single Sided Balun Panel 16 Coax to 8 RJ45, single sided, 2RU, 75/120 Order Codes M R6 M R6 M R6 M R6 BNC (f) to RJ45, 1 Side, 2 RU, 75/120, 2-8Mbit/s 1.6/5.6 (f) to RJ45, 1 Side, 2 RU, 75/120, 2-8Mbit/s BT43 (m) to RJ45, 1 Side, 2 RU, 75/120, 2-8Mbit/s 1.0/2.3 (f) to RJ45, 1Side, 2 RU, 75/120, 2-8Mbit/s Page 24

25 Patch DDF Solutions Panel Solutions DDF Temporary Patching Unit AC&E s range of matching Patch Panels complements PART No LSS the PP2 AC&E 4 range x Port of Balun panels 2 x 510 Ohm thus PART providing No LSS PP3 interconnect 4 x Port solution (SI353/970) that is 2 x 1K2 Ohm highly functional and professional in appearance. Constructed in zinc sealed, black powder coated steel they are built for long life. The Baluns, U Links, Through Adaptors and Patch Cables listed on this page have been WITH OPTIONAL PATCH LEADS: designed with compatibility in mind and are 4 Pole to 4 Pole Krone, lead 5m intended to be used in and on the patch panels length. (S308/..M) listed here to provide a complete connectivity 2 Pole to 2 Pole Krone, lead 30cm and interface solution. length. (S332/..M) Select your coaxial connectors from AC&E s range of BNC, 1.6/5.6, BT43 and LSS /2.3 listed on the web for your total requirement. Description: Blank Twisted Pair Panels Frames (Digital Distribution Frame) are common in Telephone & Data Exchanges, particularly where Krone IDC Block (modules) are used. For DDF s using 2 and 8Mbit/s services Order there is Codes often an - Blank emergency Panels need to deploy patching units at strategic positions on the frame. Part No. Description This JS1 Blank unit allows the Blank insertion Panel, anywhere 1 RU, 19, black on the powder frame coated where steel localised patching is required. Having JS4 Blank placed the unit Blank at Panel, the most 2 RU, appropriate 19, black powder position coated on the steel frame, looping in and out of the unit is simple and live traffic can be readily patched through it. Monitor positions are immediately set-up providing low risk to the main data flow (26dB or 20dB attenuation). A test access is provided as well. Each of these units has a four circuit configuration installed. A Hitless data BNC Panels & Accessories flow situation is then provided. S267/1M Order A range Codes of patch - BNC leads Panels are available for use with the unit, refer to AC&E for Technical JS7/40 BNCU BNC panel, 2 x 20, 2 RU, black powder coated steel, empty information. JS3/20 BNCU BNC panel, 1 x 20, 1 RU black powder coated steel, empty The unit features a standard Krone Block 8 position (or 10 position on request). The unit looks Order Codes - BNC Panel Accessories like a standard Block but has the necessary attenuators and wiring on the unit, which can be Balun Select any BNC Standard or Mini from this catalogue slotted into an empty position on the frame without interfering with the other Blocks. A U Link BNC (m) - BNC (m) A S267/1M Patch Cable BNC (m) - BNC (m) 1m length Features: A BNC (f)-bnc (f) through adaptor (push on), insulated AC dB or 20dB Isolation BNC (f)-bnc Resistor (f) through to avoid adaptor interruption (bayonet), risk insulated to data traffic (Hitless). Connection between the Test Point and Patch Point. Cross-Over at Patch position (allows the same cross patch cords for both normal and patch 1.6/5.6 positions). Panels & Accessories A Use of 4 Pole polarised Krone plugs, which can prevent the plugs from causing inversion connection. Order Codes 1.6/5.6 Panels JS3/48 Minimises 1656U patch 1.6/5.6 cord Panel, congestion 2x24, 1 on RU, the black DDF powder (by placing coated steel, these empty, units 15mm in the pitch appropriate JS3P/48 position 1656U on the frame). 1.6/5.6 Panel, 2x24, 1 RU, grey fibre reinforced plastic, empty, 15mm pitch Order Codes - 1.6/5.6 Circuit Panel diagram Accessories of one module shown; there are 4 modules in one unit. A Through Adaptor 1.6/5.6 (f) to 1.6/5.6 (f), uninsulated Balun Select any 1.6/5.6 Standard or Mini Balun from this catalogue A001702/15/1/N U Link 1.6/5.6 (m) - 1.6/5.6 (m) screw coupling, 15mm pitch A001716/15/2/N U Link monitor Snap coupling rear entry monitor (f) 26db 15mm pitch A001716/15/1/N U Link monitor Screw coupling rear entry monitor (f) 26db 15mm pitch A001717/15/2/N U Link monitor Snap coupling side entry monitor (f) 26db 15mm pitch S250/1M/N Patch cable 1.6/5.6 (m) - 1.6/5.6 (m), length 1m Customized Requirements Should you have a requirement for a customized Patch Panel, U Link, Balun or Cable please us at connect@acande.com with your requirement. page 25

26 Customised Video Baluns Balun Assemblies Following A selection are of examples analogue of Baluns customer are specific available products that are that designed we have for produced on request to solve specific use with interface DC to 6.5Mhz needs. composite You too video can have signals. your Such specific signals needs are addressed by AC&E, by specifying your own requirements. Contact us by phone, fax or web to discuss your requirements. typically found originating from consumer and professional video equipment. Quad Channel Balun Assembly Coupling signals from remote Video Cameras to recorders, display Order Code: B Customer: Nokia B systems and monitors in broadcasting, surveillance and security Description: applications are the most common uses. This AC&E Quad Video Channel Baluns Balun allow assembly long lengths has been of developed coaxial cable for a to be major Worldwide Telecommunication Equipment replaced with lower cost twisted pair cable. They also allow the use Manufacturer/Solutions Provider. The product features miniature of existing connectors twisted pair (4x infrastructure Type SMB) such and as an telephone RJ45 socket. cable and B This Cat 5 package computer is networking extremely cables. small and is capable of handling four channels at E1 (2.048Mbit/s) or T1 (1.544Mbit/s) rates and has an isolation voltage rating of 1.5KV DC. The AC&E Video Baluns offer the following performance features:- Features: Available in Standard and Mini Balun Enclosures No power or batteries The size is small for the purpose of converting 4 coaxial transmission IEC Standard paths BNC into coaxial one single connection RJ45 socket and packaging IDC twisted these functions pair termination into a with volume strain of relief 31 x 33 x 43mm. 75/120 transformation Various combinations of coaxial connector types can be Small size and rugged construction incorporated into this design such as 1.6/5.6, Type 43, BNC, 1.0/2.3 Minimal and Loss other distortion variations and reflection of connector per unit types can be accommodated Other Connectors (size and adjustment impedances is necessary on request to suit size of coaxial connectors) upon request. Panel solutions also available Corporate labeling can be arranged to suit major customer requirements. In addition, for the purpose of technician labeling an area for felt pen marking is provided. Low losses. Insertion Loss: < 0.5dB and Return Loss: better than 20dB. Electrical Performance Frequency Range: DC to 8MHz Connector, Drive distance: Integral Balun 100m Pair recommended max. Twisted pair Order Code: Insertion B Loss 024 (Typ): Telephone Customer: cable Telstra 0.5dB Australia (1m); 3dB (100m) Part No. Description Description: B Video Balun, Analogue, BNC (m) to Krone IDC, 75/120 Connector, Integral Balun Pair, (for Ericsson ISDN B Video Balun, Analogue, BNC (f) to Krone IDC, 75/120 PRA Interface) B Video Mini Balun, Analogue BNC (m) to AC&E clamp IDC, 75/120 Features: Allows unbalanced coaxial type 75 equipment to simply connect to 120 shielded twisted pair. It provides interfacing to two separate circuits (a go and come path). Avoid more costly and space consuming 75 hardware for patching at the distribution frame. Minimal losses and distortion - refer Black Balun characteristics. (refer page 10). Low cost and optimal size form a simple design with minimal component count, being integral with existing connectors typically used in ISDN Interface Cards on AXE Systems. Electrically shielded between adjacent circuit. Cross Talk Performance (Isolation): Adjacent Balun near End Cross Talk is better than 70dB up to 34MHz and better than 50dB up to 80MHz. Other electrical parameters - refer Standard 2-8Mbit/s Balun in this catalogue. Insertion Loss B Return Loss B Page 26

27 DB9 to Coaxial Connector As modern technology becomes more integral with our lives, many people Order require code: a multi-function B outlet 054 in every DB9(m) room to of 1.6/5.6 their home. (f) Customer: Lucent B DB9(m) to Type 43 (m) Customer: Lucent For this reason Structured Cable Systems are one of the fastest growing Description: segments of construction industries, globally. They are sold to customers A simple as future solution proofing to the against problem data of requirements, converting a enabling home automation 2Mbit/s (E1) and signal offering from greater twisted flexibility, pair using 120 patch to panels to distribute coaxial different 75 in services one compact to each adaptor. data outlet. Picture of new Active splitter unit Most This Structured device Cable has shielding Systems have compliant a broadband with EMC video subsystem. requirements This sub-system and will transmission use components performance that are separate to from the remaining ITU-T G.703 Structured requirements. Cable System This including is a typical coaxial cost cable and dedicated effective outlets. solution for transferring a clock signal DB9 to Caxial Baluns from one network to another. Coaxial cable is the traditional transmission line for video, however its use Features: in Structured Cabling Systems means that there must be dedicated outlets for the video system. The result is a non-flexible video solution. Bit rates As of one 2 and of the 8Mbit/s selling points of Structured Cabling Systems is High flexibility speed AC&E Bit rates, believed 34 to 155Mbit/s a more flexible on request. video system should be developed. Low insertion loss figures together with good return loss performance and meets the mask performance of ITU-Telecommunication G.703. (refer to mini-balun electrical performance). Imagine Gives having low an cross-talk outlet at and each excellent corner of EMC the performance. room that can provide Telephone, Adaptable to Internet other coaxial or Video connectors. by simply eg: moving BNC, SMA/B/C, a patch 1.0/2.3 etc. Designed for lead Impedance at your patch Matching panel. typically 50 or 75 to 100 or 120 or 150. Cost effective high reliability product with good surge performance Picture ITU-T of K17. VDCP05 Fly lead This is the goal AC&E have set out to achieve. We have designed a video sub-system that utilises the exact same cables and outlets as the remainder of your Structured Cable System. BVD. 16 x E1 Transmission Path Interface Module BVD is Order a Broadband Code: K125 Video Distribution Customer: system Nortel designed and manufactured by AC&E in Australia. It is a truly flexible network. Any data outlet Description: supplied by Cat5e, Cat6 or Cat7 cable can also be a video outlet. Panel assembly containing 16 x Type 43 male connectors and having 75/120 Mini Baluns By incorporating then connecting high quality to Male RF D distribution Sub Connector techniques (44 including our proven pin). balun designs, AC&E have made distribution of broadband signals through Cat5e and Cat6 UTP cables possible. Removing the requirement The assembly to install coaxial was designed cable and to work dedicated 2Mbit/s outlets. and complying with International EMC Along requirements. with increased It was flexibility, custom built BVD to also suit provides a cost advantages defined by volume offering within a one a modern cable, UTMS one outlet System. solution for all services. K125 BVD consists of both active and passive modules. Passive modules allow for Features: the provision of a customer-specified amplifier. A return path is available Allows depending for earthing on options external for amplifier and selection. paths. The 8 way active Identification module has a strip sloped which output allows stage labelling designed of each to meet the requirements transmission of differing path. cable lengths inherent in all installations. A handle is provided on the assembly to allow it to be installed in a confined space as well as Special Fly-leads, provision incorporating for sealing AC&E the assembly balun technology within the enable System BVD so that minimum exposure of the cables to plug into is the provided. standard coaxial connection on any TV. The frame is only 155 x 45mm and 75mm deep. Refer to mini-baluns for mechanical and For more information electrical detail on the BVD range please contact your AC&E representative. broadband distribution systems page 27

CCITT G.703 Baluns HC-GB- MB8S. Shielded RJ45 Jack to Male BNC Connector. STANDARD TYPE Ordering Information

CCITT G.703 Baluns HC-GB- MB8S. Shielded RJ45 Jack to Male BNC Connector. STANDARD TYPE Ordering Information CCITT G.703 Baluns REGULAR TYPE The standard single baluns come with a variety of coaxial interfaces and a RJ45 twisted pair connection. MB8S Shielded RJ45 Jack to Male BNC STANDARD TYPE M5D8S Shielded

More information

Introduction. 75 /120 OHM IDC Balun. 75 /120 Ohm IDC Mini Balun. 75 /120 Ohm Wire Wrap Balun. 75 /120 Ohm BNC to RJ45 Balun. 75 /120 Ohm Balun Panel

Introduction. 75 /120 OHM IDC Balun. 75 /120 Ohm IDC Mini Balun. 75 /120 Ohm Wire Wrap Balun. 75 /120 Ohm BNC to RJ45 Balun. 75 /120 Ohm Balun Panel BalunSolutions Content Introduction 1-2 75 /120 OHM IDC Balun 3 75 /120 Ohm IDC Mini Balun 4 75 /120 Ohm Wire Wrap Balun 5 75 /120 Ohm BNC to RJ45 Balun 6 75 /120 Ohm Balun Panel 7 75 /120 Ohm Wire Wrap

More information

MONITOR BRACKETS CCTV SYSTEMS. BT7510S Ex GST Inc GST. BT7511S Ex GST Inc GST. BT7512S Ex GST Inc GST. BT7518S Ex GST Inc GST. BT7513S Ex GST Inc GST

MONITOR BRACKETS CCTV SYSTEMS. BT7510S Ex GST Inc GST. BT7511S Ex GST Inc GST. BT7512S Ex GST Inc GST. BT7518S Ex GST Inc GST. BT7513S Ex GST Inc GST MONITOR BRACKETS BT7510S Small Flat Screen Bracket 20kg For small flat screen. Mounts screen only 20mm from wall. Security Allen Key provided Accommodates up to 20kg BT7511S Small Flat Screen Tilt Bracket

More information

CATALOG. Network Access & Connectivity

CATALOG. Network Access & Connectivity Baluns convert the G.703 interface from unbalanced 75-ohm to balanced -ohm terminations. Patton s baluns use dual BNC connectors (Models 460 and 464) or dual 1.6/5.6 coax connectors (Models 465 and 466)

More information

10. Mini Coax Connectors

10. Mini Coax Connectors . Connectors The allows multi-pole coaxial data transmission for board-to-board, cable-to-board and cable-to-cable applications with protection up to IP 65 / IP 67. At the same time, applications up to

More information

10. Mini Coax Connectors

10. Mini Coax Connectors . Connectors The allows multi-pole coaxial data transmission for board-to-board, cableto-board and cable-to-cable applications with protection up to IP65 / IP67. At the same time, applications up to 2.5

More information

Balun Ohm to 120 Ohm Balin - IDC Type Balun - Balun Panels - Balun Pigtail

Balun Ohm to 120 Ohm Balin - IDC Type Balun - Balun Panels - Balun Pigtail Balun - 75 Ohm to 120 Ohm Balin - IDC Type Balun - Balun Panels - Balun Pigtail Content - 75 Ohm to 120 Ohm Balin - IDC Type Balun - Balun Panels - Balun Pigtail 1.1 75ohm to 120ohm Balun Solutions 1.2

More information

Amphenol RF Interconnects BNC 31 Series Bayonet Lock RF Connector System

Amphenol RF Interconnects BNC 31 Series Bayonet Lock RF Connector System BNC 31 Series Bayonet Lock RF Connector System Materials Body/Finish /Nickel Centre MALE Centre FEMALE Phosphor Bronze Centre Finish Gold 30µ Insulator Delron/PBT Gasket Silicone Rubber Crimp s Annealed

More information

baluns Balun solutions TX RX defining excellence in global network solutions

baluns Balun solutions TX RX defining excellence in global network solutions baluns TX RX Balun solutions www.greenwoodscomms.com defining excellence in global network solutions Baluns IDC IDC Baluns A range of IDC baluns used to convert between balanced and unbalanced electrical

More information

High Density DDF Solution

High Density DDF Solution High Density DDF Solution Digital Distribution Frame 75 Ohm Digital Distribution Frame is designed for coaxial cable termination and cross connection in between transmission equipments in fixed or mobile

More information

CX-A6 Amplifier Installation & User Guide V9.0

CX-A6 Amplifier Installation & User Guide V9.0 CX-A6 Amplifier Installation & User Guide V9.0 Cloud Electronics Limited 140 Staniforth Road, Sheffield, S9 3HF England Tel + 44 (0) 114 244 7051 Fax + 44 (0) 114 242 5462 E-mail info@cloud.co.uk Web site

More information

Workstation Outlets GigaFlex PS6+ Modules Category 6

Workstation Outlets GigaFlex PS6+ Modules Category 6 C O M M E R C I A L N E T W O R K I N G C O P P E R 15.25 GigaFlex PS6+ Modules Category 6 AX101067 GigaFlex PS6+Module GigaFlex PS6+ Module The GigaFlex PS6+ Module is a punch down UTP connector based

More information

G.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis

G.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis JUNE 1998 MT243A MT243C-F RM243A G.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday:

More information

AESA TECHNOLOGY OF LAN CABLE

AESA TECHNOLOGY OF LAN CABLE TECHNOLOGY OF LAN CABLE CONTENT CHAPTER INTRODUCTION CHAPTER LOCAL AREA NETWORK (LAN) CHAPTER STRUCTURED CABLING SYSTEM (SCS) CHAPTER OPTICAL FIBER CABLE CHAPTER STANDARD CHAPTER COPPER LAN CABLE DESIGN

More information

120 Ohms Digital Distribution Frame Solution

120 Ohms Digital Distribution Frame Solution 120 Ohms Digital Distribution Frame Solution 120Ohm Digital Distribution Frame is designed for 120Ohms twisted pair cable termination and cross connection in between transmission equipments in fixed or

More information

Network Cables 12. Flat Ribbon Cables 13. Coaxial Cables 14. Test Cables 15. Video Interconnect Cables 16. D-Sub Cables 17

Network Cables 12. Flat Ribbon Cables 13. Coaxial Cables 14. Test Cables 15. Video Interconnect Cables 16. D-Sub Cables 17 Cable Assemblies Network Cables 2 Flat Ribbon Cables 3 Coaxial Cables 4 Test Cables 5 Video Interconnect Cables 6 D-Sub Cables 7 Circular Connector Assemblies 8 System Tails 9 Cable Looms 20 Specialized

More information

Amphenol RF. Mini-BNC Mini-BNC Connectors. Mini-BNC. Description. Features/Benefits. Applications

Amphenol RF. Mini-BNC Mini-BNC Connectors. Mini-BNC. Description. Features/Benefits. Applications Amphenol RF 100 Connectors Description Amphenol RF introduces the new generation of quality BNC connectors for the telecommunication and broadband applications for higher connector densities while preserving

More information

SMB Connectors. Adaptors-50Ω. Plug to Plug. Jack to Jack. Plug to Jack. Bulkhead Jack to Jack

SMB Connectors. Adaptors-50Ω. Plug to Plug. Jack to Jack. Plug to Jack. Bulkhead Jack to Jack SMB Connectors Adaptors-50Ω Plug to Plug 1P-801-00 Jack to Jack 1P-802-00 Plug to Jack 1P-803-00 Bulkhead Jack to Jack 1P-804-18 Mini-SMB 75Ω Straight Plug 1P75-111-00 Cable group RG316 Straight PCB Jack

More information

SMB Connectors. RF Coax Connectors. Product Facts

SMB Connectors. RF Coax Connectors. Product Facts SMB Connectors Product Facts SMB offers snap-fit coupling for quick connect/disconnect Choice of Commercial or High Rel Connectors 50 and 75 Ω MIL-Type connectors available Straight plugs and jacks are

More information

Powerlink Plus Technical

Powerlink Plus Technical CABLE MANAGEMENT mkelectric.co.uk TECHNICAL SPECIFICATION ELECTRICAL VOLTAGE RATING 63A, 250V a.c. VOLTAGE DROP L to N = 3.47 mv/a/metre run L to E = 3.47 mv/a/metre run N to E = 3.47 mv/a/metre run EARTH

More information

FMR622S DUAL NARROW BAND SLIDING DE-EMPHASIS DEMODULATOR INSTRUCTION BOOK IB

FMR622S DUAL NARROW BAND SLIDING DE-EMPHASIS DEMODULATOR INSTRUCTION BOOK IB FMR622S DUAL NARROW BAND SLIDING DE-EMPHASIS DEMODULATOR INSTRUCTION BOOK IB 1222-22 TABLE OF CONTENTS SECTION 1.0 INTRODUCTION 2.0 INSTALLATION & OPERATING INSTRUCTIONS 3.0 SPECIFICATIONS 4.0 FUNCTIONAL

More information

TNC SERIES General... 4 Interface... 5 Characteristics...6-7

TNC SERIES General... 4 Interface... 5 Characteristics...6-7 CONTENTS PAGE TNC SERIES General... 4 Interface... 5 Characteristics...6-7 TNC 50 Ω SERIES Plugs...8-9 Jacks...0- Jacks and receptacles... Receptacles...-4 Adapters... 5 Caps... 6 TNC 75 Ω SERIES Plugs...

More information

Part VI: Requirements for Integrated Services Digital Network Terminal Equipment

Part VI: Requirements for Integrated Services Digital Network Terminal Equipment Issue 9, Amendment 1 September 2012 Spectrum Management and Telecommunications Compliance Specification for Terminal Equipment, Terminal Systems, Network Protection Devices, Connection Arrangements and

More information

242, , FAX.

242, , FAX. TEL. 886 2 8994 1601, FAX. 886 2 8994 1602 sales@rfconnector.com.tw, www.rfconnector.com.tw General Information SMA SMB Subminiature Connectors Screw Lock Subminiature Connectors Snap Lock 50 Ω 18 GHz

More information

Sunridge MCB Series Miniature Coaxial Interconnect, 2.5mm or 2.0mm Mated Height

Sunridge MCB Series Miniature Coaxial Interconnect, 2.5mm or 2.0mm Mated Height Sunridge MCB series coaxial product fulfills the rigorous requirements of high frequency data transmission in digital world. Constructed in supreme Teflon coax cable and advanced mechanical design, MCB

More information

CX-A6 Amplifier Installation & User Guide V8.0

CX-A6 Amplifier Installation & User Guide V8.0 CX-A6 Amplifier Installation & User Guide V8.0 Cloud Electronics Limited 140 Staniforth Road, Sheffield, S9 3HF England Tel + 44 (0) 114 244 7051 Fax + 44 (0) 114 242 5462 E-mail info@cloud.co.uk Web site

More information

Distributed Design D SERIES D10 TWO-WAY 10-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Distributed Design D SERIES D10 TWO-WAY 10-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS APPLICATIONS Convention centers, exhibit halls Corporate training rooms, ballrooms Athletic venues, sports facilities, health clubs Houses of worship Malls, airports FEATURES High intelligibility with

More information

Part VI: Requirements for ISDN Terminal Equipment

Part VI: Requirements for ISDN Terminal Equipment Issue 9 November 2004 Spectrum Management and Telecommunications Policy Compliance Specification for Terminal Equipment, Terminal Systems, Network Protection Devices, Connection Arrangements and Hearing

More information

Distributed Design D SERIES D8 TWO-WAY 8-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Distributed Design D SERIES D8 TWO-WAY 8-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS APPLICATIONS Convention centers, exhibit halls Corporate training rooms, ballrooms Athletic venues, sports facilities, health clubs Houses of worship Malls, airports FEATURES High intelligibility with

More information

SECTION 14. DIN 1.0/2.3 / DIN 1.6/5.6 / Type 43 R118 / R120 / R129 / R214

SECTION 14. DIN 1.0/2.3 / DIN 1.6/5.6 / Type 43 R118 / R120 / R129 / R214 SECTION 14 14 DIN 1.0/2.3 / DIN 1.6/5.6 / Type 43 R118 / R120 / R129 / R214 Contents DIN 1.0/2.3 Introduction... 14-4 Interface... 14-4 Characteristics Eco... 14-5 Plugs Eco... 14-6 Jacks Eco... 14-6

More information

Data sheet C5 RJ45 field plug pro 2P PROFINET

Data sheet C5 RJ45 field plug pro 2P PROFINET Illustrations Dimensional drawing Page 1/5 See enlarged drawings at the end of document Product specification Cat.5 class D RJ45 plug, 2 pairs, to be assembled in the field fully shielded and multi-port

More information

SRS SEALED ROTARY SENSORS

SRS SEALED ROTARY SENSORS SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance

More information

Setting Standards Connectors M 16

Setting Standards Connectors M 16 Setting Standards Connectors M 16 inclusive 15 Product Overview 16 Housings page 18 Inserts page 22 Accessories page 29 Technical Data M 16 Control Signal Connectors Mechanical Data Housing Materials and

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02 Contents Page Technical characteristics circular connector with rapid termination 50.02 Circular connector M8/M12 with rapid termination... 50.05 Han M12 panel feed-through... 50.08 Han M12 pcb adapter...

More information

M2 Antenna Systems, Inc. Model No: 20M5LD

M2 Antenna Systems, Inc. Model No: 20M5LD M2 Antenna Systems, Inc. Model No: 20M5LD SPECIFICATIONS: Model... 20M5LD Frequency Range... 14.0 14.350 MHz *Gain (Full Band)... 10.2 dbi Typical Front to back... 23 db Typical Beamwidth... E=50 / H=66

More information

Introduction to Copper Products Copper Cable Assemblies

Introduction to Copper Products Copper Cable Assemblies Introduction to Copper Products Copper Cable Assemblies A copper cable assembly is only as good as its parts and at Clearfield, we only use the best parts available. Whether it s a custom cabling solution

More information

Data sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/

Data sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/ Page 1/6 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification Cat.5 class D RJ45 plug, 2 pairs, to be assembled in the field fully shielded and multi-port

More information

711 Series Single Way DB-1a

711 Series Single Way DB-1a 711 Series Single Way DB-1a Data Bus Interconnection System Data Bus Interconnection System designed for data transmission as defined by MIL-STD-1553B, STANAG 3838 and DEF STAN 00-18 (Part 2). This system

More information

AVX Wire-to-Board Connectors

AVX Wire-to-Board Connectors AVX Wire-to-Board Connectors www.avx.com Version 11.11 Table of Contents INSULATION DISPLACEMENT CONNECTORS (IDC) WIRE TO BOARD (WTB) DISCRETE WIRE IDC SERIES 9175...................................................................................

More information

Test Cable Assemblies

Test Cable Assemblies Test Cable Assemblies DC-65 GHz 8851 SW Old Kansas Ave. Stuart, FL 34997 USA +1-772-286-9300 +1-800-544-5594 sales@emc-rflabs.com www.emc-rflabs.com Premium Test Cable Lab-Flex 200 Frequency to 31 GHz

More information

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB6408-01 TABLE OF CONTENTS GENERAL DESCRIPTION 2 INSTALLATION 2,3,4 CONNECTION AND SETUP 4,5,6,7 FUNCTIONAL DESCRIPTION 8,9 MAINTENANCE 9

More information

Sunridge MCD Series Ultimate Miniature Coaxial Interconnect, 1.55mm Mated Height

Sunridge MCD Series Ultimate Miniature Coaxial Interconnect, 1.55mm Mated Height Sunridge MCD series coaxial product fulfills the rigorous requirements of high frequency data transmission in digital world. Constructed in supreme Teflon coax cable and advanced mechanical design, MCD

More information

Quick Reference Guide RF Coaxial Connectors

Quick Reference Guide RF Coaxial Connectors Quick Reference Guide Coaxial RF Products: Quick View Product Operating Frequency (Max.) Impedance VSWR Durability (Mating Cycles) Operating Temp. Coupling Style Standard 7/16 7 GHz 50 Ω 1.02 + 0.03f up

More information

Distributed Design Series

Distributed Design Series APPLICATIONS Convention centers, exhibit halls Corporate training rooms, ballrooms Athletic venues, sports facilities, health clubs Houses of worship Malls, airports FEATURES High intelligibility with

More information

CMS 603DC. Technical Data Sheet

CMS 603DC. Technical Data Sheet CMS 63DC Product description The Tannoy CMS 63DC is a full bandwidth, high power-handling and high sensitivity loudspeaker built around CMS 3. the third generation of Tannoy s revolutionary Ceiling Monitor

More information

G & H Telecoms Ltd Product Guide 2017

G & H Telecoms Ltd Product Guide 2017 G & H Telecoms Ltd Product Guide 2017 TEL: 02476 645882 1 2. Index 65. Coaxial Tooling 66. Pressmaster Pliers 6A & Die Sets 3. Coaxial Connectors 67. Inner Crimp Tools MH800 & AFM8 4. BT43 (SMZ Range)

More information

CMS 803DC. Technical Data Sheet

CMS 803DC. Technical Data Sheet CMS 83DC Product description The Tannoy CMS 83DC is a full bandwidth, high power-handling and high sensitivity loudspeaker built around CMS 3. the third generation of Tannoy s revolutionary Ceiling Monitor

More information

This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel 0.5U:

This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel 0.5U: Application 4-9300 Specification Nov 06 Rev.C AMP Netconnect* Cat.6 Compact Patch Panel 0.5U, 4 Ports. SCOPE This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel

More information

Broadband performance with low reflection DC to 4 GHz provides low cost connector combined with high quality.

Broadband performance with low reflection DC to 4 GHz provides low cost connector combined with high quality. Amphenol RF 36 Connectors Description The name derives from SubMiniature B (the second subminiature design). Developed in the 1960 s, this sub miniature interface has snap-on coupling. Amphenol s connectors

More information

Data sheet C6 A RJ45 field plug pro

Data sheet C6 A RJ45 field plug pro Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable

More information

Amphenol RF- BNC Connector Series

Amphenol RF- BNC Connector Series Page 1 of 7 enter part number Products 7/16 1.0/2.3 1.6/5.6 AMC BNC / RP-BNC C FAKRA SMB FME HN MCX Mini-UHF Mini 75 Ohm SMB MMCX Precision (APC) QDS QMA QWS SC SlimLine BNC SMA / RP-SMA SMB SMC SMP TNC

More information

RECOMMENDATION ITU-R BT.1302 *

RECOMMENDATION ITU-R BT.1302 * Rec. ITU-R BT.1302 1 RECOMMENDATION ITU-R BT.1302 * Interfaces for digital component video signals in 525-line and 625-line television systems operating at the 4:2:2 level of Recommendation ITU-R BT.601

More information

Sunridge MCF Series 2.0mm Mated Height Miniature Coaxial Interconnect

Sunridge MCF Series 2.0mm Mated Height Miniature Coaxial Interconnect Sunridge MCF series coaxial product fulfills the rigorous requirements of high frequency RF signal transmission in digital world. In a miniature form factor of 3.0mm x 3.0mm PCB foot print by 2.0mm mated

More information

Category 7 A /Class F A Products

Category 7 A /Class F A Products CATEGORY 7 A /CLASS F A PRODUCTS Category 7 A /Class F A Products Exceeding ISO/IEC category 7 A /class F A specifications, Siemonʼs fully shielded TERA endto-end cabling solution is the highest-performing,

More information

M2 Antenna Systems, Inc. Model No: 2M7

M2 Antenna Systems, Inc. Model No: 2M7 M2 Antenna Systems, Inc. Model No: 2M7 SPECIFICATIONS: Model... 2M7 Frequency Range... 144 To 148 MHz *Gain... 12.3 dbi Front to back... 20 db Typical Beamwidth... E=43 H=50 Feed type... T Match Feed Impedance....

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

WiFi Interface Identifier

WiFi Interface Identifier WiFi Interface Identifier WiFi Interface Identifier Today s wireless market has exposed us to many new, and some familiar connectors. The wide range of antennas, access points, routers, WLAN s, cellular

More information

User s Manual. CONTROL STATION COMBINER Broad Band Short Haul MHz. Document Number: INS

User s Manual. CONTROL STATION COMBINER Broad Band Short Haul MHz. Document Number: INS User s Manual CONTROL STATION COMBINER Broad Band Short Haul 40-960MHz Document Number: INS40976-1 Company Overview RFI has been serving the needs of the wireless communications market for over 30 years.

More information

JULY 2014 SECTION TITLE PAGE. 1 Description of Connectors and Intended Applications 2. 2 Marking of Connector and/or Package 2.

JULY 2014 SECTION TITLE PAGE. 1 Description of Connectors and Intended Applications 2. 2 Marking of Connector and/or Package 2. M80 & M83 SERIES RECTANGULAR CONNECTORS JULY 204 SECTION TITLE PAGE Description of Connectors and Intended Applications 2 2 Marking of Connector and/or Package 2 3 Ratings 3 Appendix Contact Orientations

More information

Distributed Design D SERIES D6 TWO-WAY 6.5-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Distributed Design D SERIES D6 TWO-WAY 6.5-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS APPLICATIONS Convention centers, exhibit halls Corporate training rooms, ballrooms Athletic venues, sports facilities, health clubs Houses of worship Malls, airports Nightclubs, bars, restaurants The is

More information

Cable Management Solutions with DLP TM

Cable Management Solutions with DLP TM DLP trunking system P. 374-375 Selection chart for DLP trunking system P. 397 Floor boxes & Under floor boxes Technical data P. 373 DLP U-PVC adaptable trunking system Cable Management Solutions with DLP

More information

Fiber Splice Box (FSB-D) Installation Instructions

Fiber Splice Box (FSB-D) Installation Instructions Fiber Splice Box (FSB-D) Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...

More information

Labs. Introduction. Specialty Family

Labs. Introduction. Specialty Family INC. Labs Introduction Specialty Family Features K-Jumper: Affordable, High Performance Interconnect up to 35 GHz Space-Flex : Semi-Rigid and Flexible Cable Assemblies for S-Level Space T-Flex : Flexible

More information

INSTRUCTION MANUAL NPPA-TT-PT PATCH PANEL Easy Patch 96 Bantam (TT) Jacks, Push Terminals

INSTRUCTION MANUAL NPPA-TT-PT PATCH PANEL Easy Patch 96 Bantam (TT) Jacks, Push Terminals INUCION MANUAL NPPA--P PACH PANEL Easy Patch 96 Bantam () Jacks, Push erminals NEUIK AG NEUIK Zürich AG NEUIK (UK) Ltd. NEUIK UA INC. NEUIK okyo Ltd. NEUIK France NEUIK Vertriebs GmbH Liechtenstein witzerland

More information

Electrical Components Catalog RF Connectors

Electrical Components Catalog RF Connectors Introduction Product Facts Designed and Manufactured to meet MI-C-39012 Requirements Wide Range of Connectors available in 50 and 75 Ohm Impedance The range offers connectors to suit from DC-11 GHz Operation

More information

Installation & Service Manual

Installation & Service Manual 869-894 MHz Installation & Service Manual Model SCA 9321-30C Single-Channel Cellular Amplifier 044-xxxxx Rev.A February 2003 2003 Powerwave Technologies Incorporated. All rights reserved. Powerwave Technologies,

More information

Data sheet C6 A RJ45 field plug pro 360

Data sheet C6 A RJ45 field plug pro 360 Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable variable

More information

242, , FAX.

242, , FAX. TEL. 886 2 8994 1601, AX. 886 2 8994 1602 sales@rfconnector.com.tw, www.rfconnector.com.tw General Information Subminiature Connectors Subminiature Connectors Snap Lock 50 Ω 18 GHz 50 Ω 75 Ω 4 GHz 3 GHz

More information

Agilent 8761A/B Microwave Switches

Agilent 8761A/B Microwave Switches Agilent 8761A/B Microwave Switches Product Overview Product Description The Agilent Technologies 8761A and 8761B are single-pole, double-throw coaxial switches with excellent electrical and mechanical

More information

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification multi-port Cat.6 class E A plug to be assembled in the field compliance with class E A to ISO/IEC 11801

More information

Important Safety Information

Important Safety Information OWNER'S MANUAL Important Safety Information 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only

More information

CVS 4. Product Description. Features. Applications

CVS 4. Product Description. Features. Applications Product Description The Tannoy CVS4 is a full bandwidth ceiling speaker system comprising a 1mm (4. ) mid bass driver with a coaxially mounted 19mm (.75 ) high frequency section mounted in a vented, injection

More information

STANDARD COAXIAL CONNECTORS. Eco 7/16 series

STANDARD COAXIAL CONNECTORS. Eco 7/16 series STANDARD COAXIAL CONNECTORS Eco 7/16 series Eco 7/16 INTRODUCTION GENERAL Standard coaxial connectors Screw on coupling Compliant to CECC and IEC standards 50 Ω APPLICATIONS Broadcast RF components (filters,

More information

SATELLITE RECEIVING SYSTEM (IF)

SATELLITE RECEIVING SYSTEM (IF) SATELLITE RECEIVING SYSTEM (IF) The Contractor shall supply, install and commission an IF Satellite Receiving System of an approved manufacturer and design, capable of receiving and distributing present

More information

24V dc Analog Block I/O Module

24V dc Analog Block I/O Module 24V dc Analog Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module. Refer

More information

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header Pluggable PCB terminals and headers Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header System features plug in system is simple

More information

Bel Stewart Connector

Bel Stewart Connector Page 1 of 8 PLUG ASSEMBLY INSTRUCTIONS FOR Cable with INDIVIDUALLY SHIELDED PAIRS (PIMF or SFTP) T568B Wiring Pattern For Cable with Overall Foil Shield (FTP), See Page 9 1 2 Cut cable to length. If you

More information

SECTION 7. SAFETYING

SECTION 7. SAFETYING 9/8/98 AC 43.13-1B SECTION 7. SAFETYING 7-122. GENERAL. The word safetying is a term universally used in the aircraft industry. Briefly, safetying is defined as: Securing by various means any nut, bolt,

More information

Stand Alone Rudder Angle Indicator System

Stand Alone Rudder Angle Indicator System ComNav Marine Ltd. Phone: 604-207-1600 #15-13511 Crestwood Place Fax: 604-207-8008 Richmond, BC E-mail: sales@comnav.com Canada V6V 2G1 Web: www.comnavmarine.com Stand Alone Rudder Angle Indicator System

More information

both pin and sleeve contacts.

both pin and sleeve contacts. The different modules are inserted into the appropriate retaining frames (which vary according to the different housing sizes). There they snap in easily and safely. A special removal tool ensures quick

More information

OD4 PRODUCT NAME. user manual. user manual. Conditioning Module. Product Type

OD4 PRODUCT NAME. user manual. user manual. Conditioning Module. Product Type OD4 Conditioning Module PRODUCT NAME Product Type user manual user manual 1.0 Index Section Title Page 1.0 Index...................... 2 2.0 Safety Information............ 3 3.0 Introduction.................

More information

The Kent Range of Metering Products Pulse Units

The Kent Range of Metering Products Pulse Units INSTALLATION INSTRUCTIONS The Kent Range of Metering Products Pulse Units For retro-fitting to H4000, S2000, C4000 and C4200 meters The H4000 Woltmann, S2000 Commercial single jet and C4000 and C4200 Combination

More information

RF Components Product Catalogue

RF Components Product Catalogue RF Components Product Catalogue Government and Defence Broadcast Marine, Oil and Gas SNG and VSAT RF Engineering by Design Contents Splitters / Combiners Active Splitters and Combiners Page 3 Passive Splitters

More information

WINSTA The Connection System. Full Line Catalog 2010/2011

WINSTA The Connection System. Full Line Catalog 2010/2011 WINSTA The Connection System Full Line Catalog 2010/2011 5 WAGO Registered Trademarks CAGE CLAMP CAGE CLAMP @ POWER CAGE CLAMP FIT CLAMP PUSH WIRE TOPJOB TOPJOB @ WINSTA WAGO X-COM X-COM @ JUMPFLEX TO-PASS

More information

RECOMMENDATION ITU-R BT *

RECOMMENDATION ITU-R BT * Rec. ITU-R BT.656-4 1 RECOMMENDATION ITU-R BT.656-4 * Interfaces for digital component video signals in 525-line and 625-line television systems operating at the 4:2:2 level of Recommendation ITU-R BT.601

More information

SMA - 50 Ohm Connectors

SMA - 50 Ohm Connectors For Flexible Cable Straight Crimp Type Plug - Captivated Contact CABLE TYPE RG-178/U, 196 1.20 +.025 f (GHz) 0-12.4 GHz 142-0402-001 142-0402-006 RG-161/U, 174,188, 316 RG-188 DS, RG-316 DS RG-58/U, 141,

More information

8 Input/8 Output AC Block I/O Module

8 Input/8 Output AC Block I/O Module 8 Input/8 Output AC Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module.

More information

CMS 603DC PI. Technical Data Sheet

CMS 603DC PI. Technical Data Sheet CMS 63DC PI Product description The Tannoy CMS 63DC PI is a full bandwidth, high power-handling and high sensitivity loudspeaker built around CMS 3. the third generation of Tannoy s revolutionary Ceiling

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

M2 Antenna Systems, Inc. Model No: 20M6-125

M2 Antenna Systems, Inc. Model No: 20M6-125 M2 Antenna Systems, Inc. Model No: 20M6-125 SPECIFICATIONS: Model... 20M6-125 Frequency Range... 14.0 14.350 MHz *Gain, (FS) / Over gnd... 11.19dBi / 16.6dBi @70 Front to back... 25 db Typical Beamwidth...

More information

Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N)

Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N) Cisco Aironet.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT588P3M-N) This document outlines the specifications for the Cisco Aironet AIR-ANT588P3M-N.4/5-GHz 8-dBi 3-Port Directional Antenna with N-connectors

More information

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

Suppliers' Information Note. BT Metallic Path Facility. Interface Description

Suppliers' Information Note. BT Metallic Path Facility. Interface Description SIN 349 Issue 2.5 August 2015 Suppliers' Information Note For The BT Network BT Metallic Path Facility Interface Description Each SIN is the copyright of British Telecommunications plc. Reproduction of

More information

Telegärtner Product Overview. Coaxial Connectors Networking Components

Telegärtner Product Overview. Coaxial Connectors Networking Components Telegärtner Product Overview Coaxial Connectors Networking Components 1 Best contact for your success Telegärtner Karl Gärtner GmbH in Steinenbronn near Stuttgart is an internationally operating provider

More information

model tsa-sa48 Sliding Crosscut Table installation guide

model tsa-sa48 Sliding Crosscut Table installation guide model tsa-sa48 Sliding Crosscut Table installation guide A Note About Color Variations Among Anodized Aluminum Components Congratulations on the purchase of this SawStop Sliding Crosscut Table. We at SawStop

More information

Safety switches with slotted hole lever

Safety switches with slotted hole lever Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the

More information

Optical Cable Entry Facility (OCEF) Installation Instructions

Optical Cable Entry Facility (OCEF) Installation Instructions Instruction Sheet 860380690 Uniprise Solutions Optical Cable Entry Facility (OCEF) Installation Instructions General The Optical Cable Entry Facility (OCEF) cabinets store optical fiber splices between

More information

COAXIAL CABLE and FITTINGS SUMMARY RF CABLE ASSEMBLIES

COAXIAL CABLE and FITTINGS SUMMARY RF CABLE ASSEMBLIES SUMMARY RF CABLE ASSEMBLIES Custom Cable Assemblies Standard Cable Sets CABLE FITTINGS 7/8" Flexible Foam Dielectric, 50 Ohm Hoisting Stocking Grips 1/2" Flexible Foam Dielectric, 50 Ohm Bird-Proof Stainless

More information

Agilent Accessories Selection Guide For Impedance Measurements. December 2008

Agilent Accessories Selection Guide For Impedance Measurements. December 2008 Agilent Accessories Selection Guide For Impedance Measurements December 2008 Table of Contents Introduction 1 1. What are Agilent Accessories? 1 2. Types of Accessories 1 3. The Benefits of Agilent Accessories