1 Section Equipment Issue Rev. C, June 2008 I2 2-Wire Foreign Exchange Station (2FXS) Dial Pulse Originating (DPO) Unit with Gain Transfer (GT) CLEI* Code: F1NUUAAA CONTENTS PAGE # 1. GENERAL APPLICATIONS CIRCUIT/FUNCTIONAL DESCRIPTION OPTIONS & FEATURES INSTALLATION ALIGNMENT ING & TROUBLESHOOTING CUSTOMER & TECHNICAL SERVICES WARRANTY & REPAIRS SPECIFICATIONS FXS/DPO/GT 2TO/GT-PLAR FXS/DPO/GTI TA/TB RA/RB FAIL 1. GENERAL 1 Document Purpose This document describes the Westell Issue 2 2-Wire Foreign Exchange Station (2FXS) Dial Pulse Originating (DPO) Unit with Gain Transfer (GT), shown in Figure 1. See Table 5 for product ordering information. - NOTE - Hereafter, the Westell Issue 2 2-Wire Foreign Exchange Station (2FXS) Dial Pulse Originating (DPO) Unit with Gain Transfer (GT) may be referred to as the." 1.2 Document Status This Revision C document updates Figure 1, Figure 4, and the company contact information. Revision B updated Paragraph 10.2, list item Y. Revision A provided a general format update, updated the company contact information, and replaced practice The previous Revision 1 clarified Switch S8-1 operation. This practice reflects the Issue 2 equipment. Whenever this practice is updated, the reason will be stated in this paragraph. 1. Product Purpose and Description The is a 2 wire Channel Unit with multiple functionality and Gain Transfer. It can be used as an 2FXS/GT, a DPO/GT or a 2TO/GT and can serve 2 wire PLAR applications. This flexible channel unit supports standard 2-wire Ground Start and Loop Start, Dial Pulse Origination, Transmission Only, Private Line Automatic Ring Down (PLAR) applications and has a number of significant enhancements to handle all of today s FXS, DPO and TO needs. This multiple function unit includes superior adaptive hybrid loss balancing to accommodate loaded and noloaded facilities with mixed gauge cables. It s adaptive hybrid Figure 1. Front View of insures that transhybrid loss balancing dynamically adjusts for changes to loop plants; guaranteeing superior performance. The may be used as a direct replacement for AT&T Technologies or other manufacturers FXS, DPO, PLAR or TO units where superior transhybrid loss characteristics or gain transfer are needed. 1.4 Product Mounting The typically mounts in one channel unit position of a mounting assembly (such as the AT&T channel bank assembly). 1.5 Product Features The offers the following features. Meets UL-1459, GR-1089, & TR-4801 Adaptive hybrid eliminates the need to set up to 25 switches for precision balance network adjustment providing superior performance Automatically adjusts transhybrid loss balance for cabling changes Supports ON-HOOK transmission for CLASS services Improved ERL & SRL due to digital adaptive transhybrid loss balancing for mixed facilities 2-wire input impedance of 00 Ω and 900 Ω Copyright 2008 Westell, Inc. All rights reserved. Westell is a registered trademark of Westell, Inc. *CLEI and CLASS are trademarks of Telcordia Technologies, and S is a registered trademark of AT&T. Page 1 of 8

2 Section Rev. C Transmit & Receive 09D equalizers for slope compensation. Supports V.4 modem transmission Provides test mode to force T1 and Drop signaling for installation verification and trouble shooting. Front panel signaling status LEDs simplify troubleshooting. Provides standard ground start, loop start signaling on 2-wire FX loops. 2-Wire PLAR (Automatic Ring Down) support for interfacing another PLAR Provides D and signaling option for PLAR 2-Wire PLAR/FX mode for interfacing another FX line or trunk Provides Dial Pulse Originating operation. Provides CGA Trunk Processing. Sealing current SUPPLY or OFF option (TO/GT) Operates with channel banks. Front panel Maintenance Access Connector (MAC or jack) provides access to XMT TLP, RCV TLP and RNDIS test points for testing and maintenance purposes. XMT and RCV attenuation selection in 0 db increments, for adjusting each transmission path for proper level coordination. Provides automatic loop current limiting. PBX LS/GS MODEM or S-9 RT Mode 1/III FXS/GT Mode= FXS, LS/GS LS/GS FXS/GT or S-9 RT Mode 1/III DPT/GT Mode= FXS, D/D FXS/GT Mode= FXS, or S-9 RT Mode 1/III 2T0/GT Mode= TO, FXO Figure 2a. 2FXS/GT Application S-9 RT Mode 1 or S-9 COT Mode 1/III Figure 2b. 2FXS/GT Integrated S9 Application Figure 2c. 2FXS/GT to DCS Application or S-9 COT Mode 1/III DPO Mode= DPO, Figure 2d. 2DPO Application or S-9 COT Mode 1/III 2TO/GT Mode= TO, CO SWITCH CO SWITCH DCS CO SWITCH Originating Trunk MODEM 2. APPLICATIONS Figure 2e. 2TO/GT Application 2 The can be used to provide Foreign Exchange Station, Dial Pulse Originate, Private Line Automatic Ringdown, or Transmission Only capability to a channel bank. 2PLAR 2PLAR 2.2 The includes gain transfer characteristics of benefit to long loops. Additional gain and equalization are provided to compensate for longer loop length characteristics. Mode= PLAR/E&M, Mode= PLAR/E&M, Figure 2f. 2PLAR/PLAR Application 2. The includes superior adaptive transhybrid loss balancing to accommodate higher levels in the network. 2.4 Some typical applications include those shown in Figure 2. 2PLAR/ FX 2FXS. CIRCUIT/FUNCTIONAL DESCRIPTION Refer to Figure ( Block Diagram) as needed while reading the following brief description of the s functions. Hybrid VF signals enter and leave the channel unit through the 2-wire port. The hybrid line interface allows dc supervisory current to flow while minimizing its effect on the VF signals. Switch selected taps provide 00 Ω or 900 Ω impedance matching; an echo canceler further improves transhybrid loss balancing for mixed facilities. The hybrid converts the 2-wire input signals to 4-wire Mode= PLAR/FX, 2PLAR/ E&M Mode= PLAR/E&M, D Figure 2. Figure 2g. 2PLAR/FXS Application D 2PLAR (D signaling) Figure 2h. 2PLAR/PLAR Application Applications 2

3 Rev. C Section RVR 27 RING RELAY +8 0 to 24dB XMT ATTN GAIN* SLOPE EQ dB TLP TPCM 5 TIP OFF LINE INTERFACE HYBRID Input Impedance 00 Ω 900 Ω CAUTION NOTE: MAC jack levels are valid only at 1000Hz CODEC Echo Canceler 51 RING 20Hz 54 SUPPLY 12 + GAIN* SLOPE EQ 0 to 24dB RCV ATTN +4dB TLP RPCM 9 4 PLAR/FXS PLAR/E&M FXS CGA/IDLE DPO TO 2 0 FGND 1 RG TG RING D/D M O D E GND X M T R C V RA RB TA TB FAIL XMT ATTN MICROPROCESSOR Figure RCV ATTN Block Diagram SL8 SL4 SL2 SL1 SLOPE * Gain at 1KHz from slope Equalizer: Slope Gain NORM XMT ATTN= 8dB loop loss +gain of slope Equalizer (assumes transmit level at digital interface 0dB) RCV ATTN= db loop loss +gain of slope Equalizer receive level desired at PBX(far end of circuit) (See example of setting XMT and RCV ATTN in Paragraph. REV BATT CHANNEL UNIT LOGIC CONTROL RNDIS TWD TSP TSQ TA TB RSQ RSP RWD RFA RFB TFCC RCLK BTFCC TCLK DGND AGND TPAMGND RPAMGND signals for XMT path use and converts 4-wire RCV signals to balanced 2-wire output signals..2 Transmit Amplifier/Attenuator The 2-wire VF signals pass through the hybrid circuitry and are coupled to the transmit amplifier/attenuator which provides from 0 to 24 db of switch-selected attenuation in 0 db steps. The transmit attenuation allows adjustment of the 2-wire input level of +1.8 dbm to -9 dbm to the -8.5 db required at the transmit TLP (pins 1 and 7 of jack J1). The jack provides access to the output of the transmit attenuator, after the equalizer.. Transmit Equalizer The transmit equalizer provides post-equalization adjustment of the cable connected to the T&R port. Adjustment settings for equalizer performance in accordance with the WORD document. The slope compensation provided is 09D type..4 Receive Amplifier/Attenuator VF signals from the codec are passed through test jacks (pins and 9 of jack J1) to the receive amplifier/attenuator. The receive attenuator provides from 0 to 24 db of switch-selected attenuation in 0 db steps. This allows for adjustment of the 2-wire output to the required level (between -9 dbm and + dbm). The VF output is coupled through the hybrid to the 2-wire port..5 Receive Equalizer The receive equalizer performs the same equalization functions as the transmit equalizer for the receive path.. Signaling Proper signaling is provided for all functions supported..7 Automatic Loop Current Limiter Limits loop current on short loops and keeps ON and OFF HOOK impedance high, yielding excellent THL in both ON and OFF HOOK states.

4 Section Rev. C TO DPO CGA/IDLE FXS PLAR/E&M PLAR/FX D/D S8 MODE S XMT ATTN S7 RG TG RING XMT IN RCV SL1 SL2 SL4 SL8 S4 IN NORM S9 REV BATT OFF RCV ATTN S5 SUPPLY S 00 S1 2FXS/DPO/GT 2TO/GT-PLAR FXS/DPO/GTI2 TA/TB RA/RB FAIL 900 Figure 4. Option/Feature Locations.8 Echo Canceler The echo canceler provides superior return loss in the presence of a variety of cable configurations. If modem presence is detected, this adaptive echo canceler is disabled. Note that the echo canceler may take a few seconds to align in the presence of a test signal. 4. OPTIONS & FRONT PANEL FEATURES The contains features and switch options located on the front and side (PCB) panels (as shown in Figure 4) to accommodate the various circuit applications. The following is a brief description of the options available to accommodate the various circuit applications. Also see Paragraph to set slope and attenuation switches. 4 Side Panel (PCB) Features & Options 4 Switch S1-2-Wire Impedance Sets the 2-wire termination to 00 Ω or 900 Ω. 4.2 Switch S2 - XMT ATTN Provides 0 to 24 db of attenuation in 0 db steps. 4. Switch S - RCV ATTN Provides 0 to 24 db of attenuation in 0 db steps. 4.4 Switch S4 - Slope Compensates for the slope characteristics of the cable. 4.5 Switch S5 - Sealing Current Supplies nominal 20 ma sealing current. 4. Switch S7 - Test Mode Sets the units operation in test modes for either transmit or receive. 4.7 Switch S8 - Mode Control Selects the basic function of the unit to FXS, DPO, PLAR/FX, PLAR/E&M, or TO. Also selects CGA/IDLE operation (only active in FXS or DPO mode), and or D/D signaling operation (D only active in PLAR/E&M mode and D signaling only used in FXS mode when integrated to a switch in S9 Mode 1). [Refer to application drawings in Figure 2.] 4.8 Switch S9 - Battery Control Sets battery to NORMal or REVerse when in Receive test mode. 4.2 Front Panel Features 4.2 Test Jack The contains a MAC-type test jack for testing purposes. This jack is labelled, as shown in Figure Front Panel Status LEDs The LEDs on the front panel provide a visual indication of the conditions. The LEDs are described in Table 1. LED Label LED Color LED Description TA Red Transmit A. LED is on when Transmit A bit is On. TB Red Transmit B. LED is on when Transmit B bit is On. RA Red Receive A. LED is on when Receive A bit is On. RB Red Receive B. LED is on when Receive B bit is On. FAIL Red Fail. LED is on when mode switch settings are invalid. Table 1. Front Panel LED Conditions and States 5. INSTALLATION Installation consists of inspecting the equipment for damages, following proper safety precautions, setting the option switches to their desired position, mounting the module in the proper slot of the mounting assembly, and performing any installer connections. The following paragraphs provide more instructions for performing these procedures. - INSPECTION NOTE - Visually inspect the unit for damages prior to installation. If the unit was damaged in transit, immediately report the damage to the transportation company and to Westell (see Part ). 4

5 Rev. C Section Option Position Function Switch # Name S1 00 Provides a impedance match for 00Ω + 25 μf termination. Termination 900 Provides a impedance match for 900Ω + 25 μf termination. S2 XMT In Adds from 0 to 24 db attenuation to the XMT path in 0 steps. Attenuation Out S RCV In Adds from 0 to 24 db attenuation to the RCV path in 0 steps. Attenuation Out S4 Slope In Provides slope adjustment. Out S5 Sealing Off Does not supply or terminate sealing current (TO mode). Current Supply Supplies nominal 20 ma sealing current (TO mode). NOTE: In non TO modes, this switch MUST be set to SUPPLY. S7 S7-1 XMT Set for normal operation. Activates transmission test mode. S7-2 When in transmission test mode, forces Loop Closure. When in transmission test mode, forces No Loop Closure. S7- RG When in transmission test mode, forces Ring Ground. When in transmission test mode, forces No Ring Ground. S7-4 RCV Set for normal operation. Activates receive test mode. S7-5 TG When in receive test mode, forces Tip Ground. When in receive test mode, forces No Tip Ground. S7- RING When in receive test mode, forces Ring. When in receive test mode, forces No Ring. S9 RCV SIG XMT BATT NORM Forces normal battery signaling condition. CONTROL XMT BATT REV Forces reverse battery signaling condition. S8 S8-1 D/D D or D signaling (D signaling only active when in PLAR/E&M mode. Use FXS mode and D signaling when in an integrated S9 Mode 1 application). Mode Control signaling all other applications [See application drawings in Figure 2]. S8-2 PLAR/FX Private line Auto Ringdown to Foreign exchange application. S8- PLAR/FX Private Line Auto Ringdown to PLAR application. S8-4 FXS Foreign exchange Station Loop or Ground Start application. S8-5 CGA/IDLE During Carrier Group Alarm (CGA), IDLE is sent continuously. S8- DPO Dial Pulse Originate application. S8-7 TO Transmission Only application. During CGA, send IDLE 1 st 2.5 sec then BUSY (FXS or DPO mode). Table 2. Switch Option Settings 5 Mounting the Module Westell s mounts in one channel unit position of a mounting assembly. After setting the option switches per the desired application (see Parts 2 and 4, Figure 4, and Table 2), align the module with the mounting or assembly card guides above and below the module and insert it as far as it will go into the slot connector. CAUTION - STATIC-SENSITIVE This product contains static-sensitive components! Proper electrostatic discharge procedures must be followed to maintain personal and equipment safety. Do not store units near magnetic, electromagnetic or electrostatic fields. Always store or ship units in the original static-protective packaging from Westell. Use anti-static mats when working on units. 5

6 Section Rev. C - CAUTION - Use care when installing and removing modules - do not force a module into place. If a module resists insertion, remove it to check for obstructions by the connectors and mounting slots, then carefully re-align and gently re-insert module. - PRECAUTIONARY STATEMENT - Never install telephone wiring during a lightning storm. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. Use caution when installing or modifying telephone lines. This equipment is intended to be used behind devices that provide primary lightning protection. This equipment is to be installed in a restricted access location. 5.2 Making Installer Connections Installer connections for the drop-side ports of the and the RT loop are made via the connectorized cables of the AT&T channel bank assembly. The RT loop connections to the connectorized cables are made at the Main Distribution Frame using the appropriate T&R cable pairs for the mounting position of the. All other connections required by Westell s, including power, are integral to the channel bank assembly. Pin-outs for the are shown in Table. Lead Designation Pin # T - Tip 24 R - Ring 51 TA TB 4 RFA 10 RFB SIGNAL LEADS 7 RCLK 8 BTFCC 21 TCLK 11 TPCM 5 RPCM 9 RNDIS 14 TFCC 12 TWD TSP 7 ADDRESS LEADS TSQ 8 RWD 9 RSP 1 RSQ V 4-12V 2 +5V 0 DGND 5 POWER AGND FGND 1 T PAM GND 29 R PAM GND 42 Table. Pin/Lead Designations. ALIGNMENT Set levels and slope adjustments according to WORD document for GT type units. Alternately, the procedure for setting slope may be found in AT&T publication and transmit and receive levels by the following formulas: XMT ATTN = 8dB - loop loss + Gain of Slope Equalizer (assumes 0 db desired at digital interface) RCV ATTN = db - loop loss + Gain of Slope Equalizer - RCV level desired at PBX Gain from Slope Equalizer Slope setting Gain (db) Slope setting Gain (db) Example: Loop loss is 7 db; slope setting is yielding 0. db gain; 0 db is desired into digital interface and -4 dbm is desired level at PBX Then set XMT ATTN to 1. db = and set RCV ATTN to. db = (-4).2 For applications where non-gt units are being replaced by this unit increase the transmit attenuation by.5 db, and increase the receive attenuation by db. In addition slope settings should be set to ING & TROUBLESHOOTING 7 Testing 7 The may be used on a Sierra 41 channel unit extender (CUE) with the DATA PORT switch in the DATA PORT position. The signaling test functions of the Sierra extender will not function properly. This occurs because the uses an onboard CODEC and signaling functions take place on the PCM highway rather than the signaling highways on the backplane. 7.2 The has signaling test functions built in. Special test switches are mounted on the surface of the board requiring the to be placed on a standard CUE, such as a AT&T model J9872 ME, MF or MP CUE or equivalent, for access. See Table 4 and Figure 4 for the functions of the switches. 7. This equipment should not be field repaired. If the equipment is suspected of being faulty, replace it with another unit, optioned identically, and retest. If the replaced unit appears to operate correctly, the original unit may be faulty and should be returned to Westell for repair or replacement (Paragraph 9.2). 7.2 Troubleshooting If trouble is found, verify all installer connections and option settings, verify the modules are making a positive connection with the shelf connector. If trouble persists, replace the suspect unit and repeat procedures outlined. These procedures are not designed to effect repairs or modifications, and are intended only to ascertain proper operation of the unit and, if problems should occur, to isolate the problems to the most probable area. Tests beyond those outlined herein, or repairs made beyond replacing a faulty unit, are not recommended and may void the warranty.

7 Rev. C Section Mode XMT Switch XMT AB BITS RCV Switch Output to T&R Equivalent RCV AB DPO NOT 00 NORM NORM. BATT 0X 11 REV REV BATT. 1X Note: RG Switch ignored in DPO Note: TG and Ring ignored in DPO X: Don t care FXS NOT TG NOT RG NOT 01 RING NOT NO TG 1 X S9 NORM TG RG NOT 11 RING NOT NORM BATT 0 1 S9 NORM NOT TG RG 00 RING NOT REV BATT 0 1/0 S9 REV TG OR TG NOT RG 01 RING RINGING 0 0 S9 NORM OR REV Note: 1/0 Toggle PLAR E&M NOT D D RG NOT RING NOT NORM BATT RG NOT RING RINGING Note: RG & S9 Switches ignored in any PLAR mode. will do 2 seconds ringing and 4 seconds off until ring trip when RCV RING switch S7- is set. PLAR/FX NOT RG NOT 01 (Idle for FX) RING NOT NORM BATT 01 RG NOT 00 (Ringing for FX) RING RINGING 11 Table 4. Test Switch Function by Mode 8. CUSTOMER & TECHNICAL SERVICES If technical or customer assistance is required, contact Westell by calling or using one of the following options: Voice: (800) global_support@westell.com For additional information about Westell, visit the Westell World Wide Web site at 9. WARRANTY & REPAIRS 9 Warranty Westell warrants this product to be free of defects at the time of shipment. Westell also warrants this product to be fully functional for the time period specified by the terms and conditions governing the sale of the product. If an out-of-service situation exists, a replacement unit can be obtained; however, a purchase order number will be required to ensure return of the replacement unit. Any attempt to repair or modify the equipment by anyone other than an authorized Westell representative will void the warranty. 9.2 Repair and Return Westell will repair or replace any defective Westell equipment without cost during the warranty period if the unit is defective for any reason other than abuse, improper use, or improper installation. To return defective equipment, first request a Return Material Authorization (RMA) number from Westell by calling or using one of the options shown below. Once an RMA number is obtained, return the defective unit (freight prepaid), along with a brief problem description, to the address we will provide to you when you contact us. Voice: (0) rgmdept@westell.com Replacements will be shipped in the fastest manner consistent with the urgency of the situation. Westell will continue to repair or replace faulty equipment beyond the warranty period for a nominal charge. Contact Westell for details. 10. SPECIFICATIONS 10 Ordering Specifications To order units, call the telephone number shown in Part 8 and please specify a specific model number shown in Table 5. Model # Part # Description I2, 2FXX/DPO/GT Channel Unit. CLEI* Code: F1NUUAAA. Barcode/ECI: *CLEI is a trademark of Telcordia Technologies. Table 5. Ordering Information 7

8 Section Rev. C 10.2 Electrical and Physical Specifications The electrical and signalling specifications are listed below, and the physical specifications are shown in Table. A. Network Interface: 4 Kb/s DS0, mechanics. B. CODEC: Standard 8 bit μ-law robbed-bit signaling for. C. Nominal Levels, Including Slope Compensation (TLP): XMT Input: +7.5 dbm to -9 dbm (Limited in practice from 0 to -9 db TLP). RCV Output: + dbm to dbm (limited in practice from + to -9 db TLP). D. Nominal Levels, Not Including Slope Compensation (TLP): XMT Input: +1.8 dbm to -8 dbm. RCV Output: + dbm to -9 dbm. E. Attenuation (Switch Selectable): XMT and RCV; 0 to 24 db in 0 db steps. F. Test Level Point (TLP): XMT RCV G. 2-Wire Impedance (Switch Selected): 00Ω + 25 μf. 900Ω + 25 μf. H. 2-Wire Return Loss: ERL: >28 db. SRL HI/LO: >20 db. I. Transhybrid Loss (typical, including loop): ERL >25 db; SRL >20 db. J. Longitudinal Balance: Hz: >58 db. 000 Hz: >5 db K. Slope Equalization: 09D Transmit & Receive equalizers with equalization in 1 steps. See Block Diagram. L. Idle Channel Noise: XMT and RCV <20 dbrnco. WORKING LOOP RANGES M. Loop Resistance Range: 0 to 2000Ω. 20 Hz. ringing range ohms (including loop and subscriber end). Ringing Trip range ohms ranges (including loop and subscriber end). Supervision (dialing range) ohms ranges (including loop and subscriber end). N. Loop Current: 20 ma or more for 48 volt battery and 2000 ohms, 18 ma or more for 42.5 volt battery and 2000 ohms. Off-hook detection threshold: 1 ma. Ground Start signaling: 1500 ohms maximum (Ring lead is connected through 1500 ohms to -5 volts or less). O. Effective Source Resistance: (2 ga. cable & -48 Vdc) Cable Length R source Cable Length R source 0 Kft 141 ohms 15 Kft 42 ohms Kft 189 ohms 18 Kft 489 ohms Kft 118 ohms 21 Kft 514 ohms 9 Kft 888 ohms 24 Kft 540 ohms 12 Kft ohms P. Filtered Battery Voltage: to -5 volts Normal and Reverse battery. Q. Sealing current source: Supply 20 ma loop current or signaling current off. R. On-hook transmission level: 4.5 db lower than off-hook transmission level. S. Immunity to AC Induction: > 28 ma rms., 0 hz, AC induction in the Tip and Ring lead. T. Distinctive Ringing Distortion: < 18 msec. U. Forward Disconnect (FXS mode function): FXS shall open the Tip lead for more than 800 msec when the RCV signaling has open switch interval for more than 400 msec. TRUNK CONDITIONING DURING CARRIER GROUP ALARM: XMT and RCV transmission disabled V. FXS: Open Tip Ground Relay and Ringing Relay for 2.5 seconds then forces the Tip Ground Relay on until CGA is cleared, if CGA/IDLE is NOT selected. W. DPO: On-hook signaling for 2.5 seconds, then off-hook (reverse battery) until CGA cleared, if CGA/IDLE is NOT selected. X. PLAR: Open Tip Ground and Ringing Relay. MODE: Y. FXS: Force Ring Ground, Loop Closure signaling toward T1. Force Tip Ground, Ringing toward drop. Note: The power efficient battery feed circuit used on this unit may make it difficult to detect Tip grounds with some Volt-Ohm meters that use a low internal source voltage. Z. DPO: Force loop closure toward T1. Force Normal/Reverse battery toward drop. AA. PLAR: Force loop closure toward T1. Force ringing toward drop. SWITCHES: AB. XMT Mode: Normal/Test; (when in Test, the following switches are active - Ring Ground/No ring Ground; Loop Closure/No ). AC. RCV Mode: Normal/Test; (when in Test, the following switches are active - Tip Ground/No Tip Ground; Battery - Normal/Reverse; Ringing/ No Ringing). AD. Function Mode Switches: FXS, DPO, PLAR/E&M, PLAR/ FX, TO. AE. LED indications: Transmit A & B bits; Receive A & B bits; Fail. AF. Power: +12, -12, +5 VDC supplies. AG. Power Consumption: 1.2 W, nominal total. 50mW nominal +5V 200mW nominal -12V 240mW nominal +12V 48mW nominal -48V AH. Complies with following technical references: UL1459 AT&T PUB 4801 Telcordia GR-1089-CORE Physical Feature U.S. Metric Height 4.44 in cm Width 1.7 in..48 cm Depth (w/o handle) 9.9 in. 25 cm Weight (approx.) 14 oz. 97 g Operating Temp. 2 to 122 F 0 to 50 C Humidity Table. 0 to 95% (non-condensing) Physical Specifications 8

W FXS LS/GS Channel Unit 600 Ohms

W FXS LS/GS Channel Unit 600 Ohms Telecommunications Group Equipment Issue 1 Second Printing, September 2000 3657 03 FXS LS/GS Channel Unit 600 Ohms CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

Figure FXS Front Panel. Figure FXS Front Panel

Figure FXS Front Panel. Figure FXS Front Panel Telecommunications Group Section 365-780-202 Equipment Issue 2 Fifth Printing, October 2006 12-Channel (3657-80) and 6-Channel (3657-81) 2-Wire Foreign Exchange Subscriber, Private Line Automatic Ringdown

More information

Wire Transmission Only with Sealing Current (4W TO W/SC) Channel Unit

Wire Transmission Only with Sealing Current (4W TO W/SC) Channel Unit Telecommunications Group Section 365 305 202 Equipment Issue 2 Second Printing, September 2000 3653 05 4-Wire Transmission Only with Sealing Current (4W TO W/SC) Channel Unit CONTENTS Complies with UL

More information

Wire Foreign Exchange Office with Loop to E&M Conversion (2W FXO LP/E&M) Channel Unit

Wire Foreign Exchange Office with Loop to E&M Conversion (2W FXO LP/E&M) Channel Unit Telecommunications Group Equipment Issue 5 Fourth Printing, September 2000 3658 06 2 Wire Foreign Exchange Office with Loop to E&M Conversion (2W FXO LP/E&M) Channel Unit CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

Loop Signaling Repeater Model

Loop Signaling Repeater Model General Description & InstallationPractice 030-100058 ev. F Loop Signaling epeater Model 4370-00 Section 4370-00-100 Issue B Westell, Inc. September 1999 All ights eserved Contents 1. General page 1 2.

More information

W Universal SF (USF) Channel Unit

W Universal SF (USF) Channel Unit Telecommunications Group Section 365 400 205 Equipment Issue 5 Fourth Printing, January 2001 3654 00 4W Universal SF (USF) Channel Unit CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

/04 2-Wire Foreign Exchange Office (2W FXO) Channel Units

/04 2-Wire Foreign Exchange Office (2W FXO) Channel Units Telecommunications Group Equipment Issue 5 Sixth Printing, April 2000 3658 01/04 2-Wire Foreign Exchange Office (2W FXO) Channel Units CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

Westell DS1 Network Interface Unit

Westell DS1 Network Interface Unit Section 312-552-20A Equipment Issue A 030-100940 Rev. D, July 2008 Westell 3125-52 DS1 Network Interface Unit CLEI* Code: T1SMM055AA CONTENTS PAGE # 1. GENERAL.................................... 1 2.

More information

Data Channel Interface W/SC Generator

Data Channel Interface W/SC Generator Telecommunications Group Section 730 546 203 Equipment Issue 3 Second Printing, October 1999 7305 46 Data Channel Interface W/SC Generator CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

Wire Loop Signaling Repeater, Loop Start Only

Wire Loop Signaling Repeater, Loop Start Only Telecommunications Group Section 730 530 202 Equipment Issue 2 Second Printing, October 1999 7305 30 2-Wire Loop Signaling Repeater, Loop Start Only CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

kbps Asynchronous Data Channel Unit

kbps Asynchronous Data Channel Unit Telecommunications Group Section 363 600 201 Equipment Issue 1 Second Printing, April 2000 3636 00 0 20kbps Asynchronous Data Channel Unit CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

Wire Duplex (2W DX) Channel Unit

Wire Duplex (2W DX) Channel Unit Telecommunications Group Section 365 900 201 Equipment Issue 1 Fourth Printing, September 2000 3659 00 2 Wire Duplex (2W DX) Channel Unit Recognized under Underwriters Laboratories Standard 1459, Second

More information

Wire Line Amplifier

Wire Line Amplifier Charles Industries, Ltd. Section 040 100 208 Equipment Issue 8 Third Printing, March 1999 401 00 4-Wire Line Amplifier CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

GDC 086R Issue 4, 10/17/97. Installation and Operation. Metroplex Flexi-Voice Plus Model MP General DataComm

GDC 086R Issue 4, 10/17/97. Installation and Operation. Metroplex Flexi-Voice Plus Model MP General DataComm GDC 086R603-001-04 Issue 4, 10/17/97 Installation and Operation Metroplex 6000 Flexi-Voice Plus Model MP 6360 General DataComm Manual Revision History Shown below is a chronological listing of revisions

More information

High-Speed Voice and Data Link Repeater

High-Speed Voice and Data Link Repeater Telecommunications Group Section HVD-54X-201 Equipment Issue 1 Fourth Printing, March 2002 High-Speed Voice and Data Link Repeater CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

VC-4/4A, VC-8/8A, VC-16

VC-4/4A, VC-8/8A, VC-16 Data Sheet Megaplex-4, Megaplex-2100/2104 VC-4/4A, VC-8/8A, VC-16 E&M, FXS or FXO options Caller ID A-law or µ-law companding Optional inband signaling with A-law encoded channels PCM (64 kbps) and ADPCM

More information

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice MEGAPLEX-2100 MODULE VC-1A 1-Channel PCM/ADPCM Voice Module Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications No part of this publication

More information

VC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules

VC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules 4, 8 or 16 analog voice channels using 64 kbps toll-quality PCM encoding; 24/32 kbps ADPCM encoding option for 4- and 8-channel modules E&M, FXS or FXO interface options Caller ID A-law or μ-law companding

More information

SERIES 5-COMPATIBLE INTELLIGENT 4W ETO CHANNEL UNIT MODEL AUA441C (ISSUE 2) (*CLEI Code: 5SC2XM02AA)

SERIES 5-COMPATIBLE INTELLIGENT 4W ETO CHANNEL UNIT MODEL AUA441C (ISSUE 2) (*CLEI Code: 5SC2XM02AA) Section 72--00 Technical Publications April 1993 57-000174 INTELIPORT SLC SERIES 5-COMPATIBLE INTELLIGENT 4W ETO CHANNEL UNIT MODEL (ISSUE 2) (*CLEI Code: 5SC2M02AA) CONTENTS PAGE 1. GENERAL 1 2. APPLICATIONS

More information

MODEL CM-30. Technical Practice November 2002 Issue 4. Service Observing System 1. GENERAL 2. DESIGN FEATURES CONTENTS: Model CM-30

MODEL CM-30. Technical Practice November 2002 Issue 4. Service Observing System 1. GENERAL 2. DESIGN FEATURES CONTENTS: Model CM-30 Model CM-30 Technical Practice November 2002 Issue 4 MODEL CM-30 Service Observing System 1. GENERAL 1.01 The DEES CM-30 is a complete 30 line service observing system with integrated talk assist capability.

More information

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 2017A RS-232 to 20ma Current Loop Converter Part# 07M2017A-A Doc# 073021UA Revised 10/15/93 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY

More information

GPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.

GPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification. GPNP Inc. NT384 NT1 User Manual Revision 1.00 17/6/2002 Information in this guide is subject to change without notification. Copyright 2002 GPNP Inc. U.S.A. IMPORTANT SAFETY INSTRUCTIONS When using your

More information

Wilcom MODEL T136BGMZW CIRCUIT TEST SET. Operating Instructions

Wilcom MODEL T136BGMZW CIRCUIT TEST SET. Operating Instructions Wilcom MODEL T136BGMZW CIRCUIT TEST SET Operating Instructions T136BGM Current Test Set Operating Instructions 811-233-010 February 2007 Copyright (c) 2007 Wilcom All Rights reserved Wilcom reserves the

More information

Data Isolation Cards. 2-Wire HDSL/56KBS Isolation Card P Wire HDSL/56KBS Isolation Card P30050

Data Isolation Cards. 2-Wire HDSL/56KBS Isolation Card P Wire HDSL/56KBS Isolation Card P30050 Data Isolation Cards 2-Wire HDSL/56KBS Isolation Card P30076 4-Wire HDSL/56KBS Isolation Card P30050 Printed in USA 12/11 T0331 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT OVERVIEW 2 2.1 System

More information

R-F Skewed Hybrids. Type H1SB and H1SB-R. & R-F Balanced Hybrids Type H1R, H3X and Type H1RB, H3XB and Type H1RB-40. System Manual CH44 VER03

R-F Skewed Hybrids. Type H1SB and H1SB-R. & R-F Balanced Hybrids Type H1R, H3X and Type H1RB, H3XB and Type H1RB-40. System Manual CH44 VER03 R-F Skewed Hybrids Type H1SB and H1SB-R & R-F Balanced Hybrids Type H1R, H3X and Type H1RB, H3XB and Type H1RB-40 System Manual CH44 VER03 (Replaces CH44-VER02) AMETEK Power Instruments 4050 NW 121st Avenue

More information

Wilcom MODEL T136BSBZW CIRCUIT TEST SET. Operating Instructions

Wilcom MODEL T136BSBZW CIRCUIT TEST SET. Operating Instructions Wilcom MODEL T136BSBZW CIRCUIT TEST SET Operating Instructions T136BSB Current Test Set Operating Instructions 811-230-007 February 2007 Copyright (c) 2007 Wilcom All Rights reserved Wilcom reserves the

More information

IOR7231SB Intelligent T1 Office Repeater CLEI* Code: T1R6KSKAAA

IOR7231SB Intelligent T1 Office Repeater CLEI* Code: T1R6KSKAAA Section IOR7231SB201 Equipment Issue 1 030101540 Rev. B, June 2008 IOR7231SB Intelligent T1 Office Repeater CLEI* Code: T1R6KSKAAA CONTENTS PAGE # 1. GENERAL.................................... 1 2. APPLICATIONS...............................

More information

Kilomux-2100/2104 KVF.4 2-Channel Low Bit Rate Voice/Fax Module

Kilomux-2100/2104 KVF.4 2-Channel Low Bit Rate Voice/Fax Module Data Sheet Kilomux-2100/2104 KVF.4 High quality voice at 4.8, 6.4, 7.2, 9.6 or 12.8 kbps Fax Group III support with automatic rate fallback Double compression (tandeming) Transfers modem data relay at

More information

MH Data Access Arrangement Preliminary Information. Features. Description. Applications. Ordering Informations

MH Data Access Arrangement Preliminary Information. Features. Description. Applications. Ordering Informations MH884 Data Access Arrangement Features FAX and Modem interface (2) ariants available with different line impedances Provides reinforced barrier to international PTT requirements Transformerless 2-4 Wire

More information

A53106 SERIES DC-TO-DC CONVERTER

A53106 SERIES DC-TO-DC CONVERTER INSTALLATION & MAINTENANCE A53106 SERIES DC-TO-DC CONVERTER AUGUST 2011, REVISED AUGUST 2014 DOCUMENT NO. COM-00-04-20 VERSION C.1 Siemens Industry, Inc., Rail Automation 9568 Archibald Ave., Suite 100,

More information

1825 Duet Plus Installation Guide

1825 Duet Plus Installation Guide 1825 Duet Plus Installation Guide Algo Communication Products Ltd. www.algosolutions.com 90-00046B - 1 - Table of Contents Release 2 Updates - Feb. 2012... 3 Quick Install for Dry Contact Ringing... 4

More information

V-9963 DIGITAL FEEDBACK ELIMINATOR

V-9963 DIGITAL FEEDBACK ELIMINATOR VSP-9963 Issue V-9963 DIGITAL FEEDBACK ELIMINATOR GENERAL DESIGN The V-9963 is designed to eliminate acoustic feedback. When a page is made, the message is digitized and saved. Upon completion of the live

More information

Wilcom MODEL T336B CIRCUIT TEST SET. Operating Instructions

Wilcom MODEL T336B CIRCUIT TEST SET. Operating Instructions Wilcom MODEL T336B CIRCUIT TEST SET Operating Instructions T336B Circuit Test Set Operating Instructions 810-311-007 June 2005 Copyright (c) 2005 Wilcom All Rights reserved Wilcom reserves the right to

More information

Installation & Service Manual

Installation & Service Manual 869-894 MHz Installation & Service Manual Model SCA 9321-30C Single-Channel Cellular Amplifier 044-xxxxx Rev.A February 2003 2003 Powerwave Technologies Incorporated. All rights reserved. Powerwave Technologies,

More information

200Amp AC Clamp Meter + NCV Model MA250

200Amp AC Clamp Meter + NCV Model MA250 User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,

More information

3 Tone Slope FINAL TEST using manual meter mode process 5 Point Test and COT Assistance

3 Tone Slope FINAL TEST using manual meter mode process 5 Point Test and COT Assistance 3 Tone Slope FINAL TEST using manual meter mode process 5 Point Test and COT Assistance These test results will not be captured in the EXP manager, but are the minimum requirements to close a ticket or

More information

TLS-3A. Telephone Line Simulator. User Manual , Rev. B Covers Model TLS-3A-01

TLS-3A. Telephone Line Simulator. User Manual , Rev. B Covers Model TLS-3A-01 User Manual TLS-3A Telephone Line Simulator 40-400-00010, Rev. B Covers Model TLS-3A-01 Teltone Corporation 22121-20th Avenue SE Bothell, Washington 98021-4408 USA Phone: 1-800-426-3926 or 425-487-1515

More information

User s Manual. Ground Resistance Clamp On Tester MODEL

User s Manual. Ground Resistance Clamp On Tester MODEL User s Manual Ground Resistance Clamp On Tester MODEL 382357 Warranty EXTECH INSTRUMENTS CORPORATION warrants the basic instrument to be free of defects in parts and workmanship for one year from date

More information

XMU+ Environmental, Safety and Specifications

XMU+ Environmental, Safety and Specifications XMU+ Environmental, Safety and Specifications Physical Unit Dimensions: Rack Width: Rack Space: Shipping Dimensions: Unit Maximum Weight: Shipping Maximum Weight: Power and Thermal Power Consumption: Heat

More information

F272xB Fiber optic 4-Wire Telephone/Audio Modem Technical Manual

F272xB Fiber optic 4-Wire Telephone/Audio Modem Technical Manual F272xB Fiber optic 4-Wire Telephone/Audio Modem Technical Manual Revision A March 2015 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since 1958

More information

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585) SC200 Series Signal Conditioner MNX10020, REV H 10/17/2012 1 CONTENTS SECTION 1: OVERVIEW... 4 Introduction... 4 Description... 4 Ordering Information... 4 Specifications... 5 Environmental... 5 Electrical...

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

VC-6 6-Channel PCM Voice Module MEGAPLEX-2100 MODULE

VC-6 6-Channel PCM Voice Module MEGAPLEX-2100 MODULE Installation and Operation Manual VC-6 6-Channel PCM Voice Module MEGAPLEX-2100 MODULE MEGAPLEX-2100 MODULE VC-6 6-Channel PCM Voice Module Installation and Operation Manual Notice This manual contains

More information

Copyright Teletronics International, Inc. Patent Pending

Copyright Teletronics International, Inc. Patent Pending Copyright 2003 By Teletronics International, Inc. Patent Pending FCC NOTICES Electronic Emission Notice: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

More information

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LCM100 Line Carrier Modem It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of equipment. Product

More information

1995 Metric CSJ , etc. SPECIAL SPECIFICATION ITEM D-I Muldem (Drop/Insert Multiplexor/Demultiplexor)

1995 Metric CSJ , etc. SPECIAL SPECIFICATION ITEM D-I Muldem (Drop/Insert Multiplexor/Demultiplexor) 1995 Metric CSJ 0924-06-156, etc. SPECIAL SPECIFICATION ITEM 6588 D-I Muldem (Drop/Insert Multiplexor/Demultiplexor) 1. Description. This Item shall govern for the furnishing and installation of intelligent

More information

Part I: Requirements for Terminal Equipment (TE) and Related Access Arrangements Intended for Direct Connection to Analog Wireline Facilities

Part I: Requirements for Terminal Equipment (TE) and Related Access Arrangements Intended for Direct Connection to Analog Wireline Facilities Issue 9, Amendment 5 March 2016 Spectrum Management and Telecommunications Compliance Specification for Terminal Equipment, Terminal Systems, Network Protection Devices, Connection Arrangements and Hearing

More information

Series 3000 Model R-107A

Series 3000 Model R-107A Series 3000 Model R-107A DUAL TONE SENDER INSTRUCTION MANUAL Monroe Electronics 100 Housel Ave Lyndonville NY 14098 800-821-6001 585-765-2254 fax 585-765-9330 monroe-electronics.com Printed in USA Copyright

More information

CYG2020/CYG2021 RING HOOKSWITCH LOOPI OH RING RING RING R_LIM

CYG2020/CYG2021 RING HOOKSWITCH LOOPI OH RING RING RING R_LIM CYG0XX Cybergate TM Features Low distortion transformer signal coupling (0.0% max) Complete ring detector circuit Low power hookswitch Electronic inductor/gyrator circuit Surge protection Transient protection

More information

LCA. Loop Current Set. Impedance Network. External Signal Input RRD REVC ESI ESE Z900 Z600 Z1 Z2 GRX1 GRX0 RX GTX1 GTX0 TX

LCA. Loop Current Set. Impedance Network. External Signal Input RRD REVC ESI ESE Z900 Z600 Z1 Z2 GRX1 GRX0 RX GTX1 GTX0 TX DID/OPS SLIC Features Programmable gain, network balance and impedance Transformerless 2-4 wire conversion Constant current with constant voltage fallback for long loop capability Pin compatible with MH88632

More information

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA MBC10641 Bipolar Microstep Driver User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com

More information

Passive Component LCR Meter

Passive Component LCR Meter User's Guide Passive Component LCR Meter Model 380193 LCR M eter 380193 APO AUTO c PAL D 1kHz µ F -0 ENTER L/C/R Q/D/R 1 2 3 RANGE L/C/R Q/D/R 4 5 6 >2sec HOLD MIN MAX SET 7 8 9 REL Hi / Lo LIMITS TOL

More information

Keysight U9397A/C FET Solid State Switch (SPDT)

Keysight U9397A/C FET Solid State Switch (SPDT) Keysight U9397A/C FET Solid State Switch (SPDT) Operating and Service Manual Notices Copyright Notice Keysight Technologies 2007-2017 No part of this manual may be reproduced in any form or by any means

More information

User Guide. Digital AC/DC Clamp Meter Model 38394

User Guide. Digital AC/DC Clamp Meter Model 38394 User Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,

More information

Model Hz to 10MHz Precision Phasemeter. Operating Manual

Model Hz to 10MHz Precision Phasemeter. Operating Manual Model 6610 1Hz to 10MHz Precision Phasemeter Operating Manual Service and Warranty Krohn-Hite Instruments are designed and manufactured in accordance with sound engineering practices and should give long

More information

Part VI: Requirements for Integrated Services Digital Network Terminal Equipment

Part VI: Requirements for Integrated Services Digital Network Terminal Equipment Issue 9, Amendment 1 September 2012 Spectrum Management and Telecommunications Compliance Specification for Terminal Equipment, Terminal Systems, Network Protection Devices, Connection Arrangements and

More information

DATASHEET HC5503T. Features. Applications. Ordering Information. Block Diagram. Balanced PBX/Key System SLIC, Subscriber Line Interface Circuit

DATASHEET HC5503T. Features. Applications. Ordering Information. Block Diagram. Balanced PBX/Key System SLIC, Subscriber Line Interface Circuit NOT RECOMMENDED FOR NEW DESIGNS RECOMMENDED REPLACEMENT PART HC5503PRC Balanced PBX/Key System SLIC, Subscriber Line Interface Circuit DATASHEET FN4506 Rev 2.00 The Intersil HC5503T is a low cost Subscriber

More information

Loop Current Holding Circuit

Loop Current Holding Circuit XE1030 September 2004 SIP DAA Provides 3750 Volt Isolation Barrier Description Xecom s XE1030 is a complete DAA in a compact Singlein-Line package. It provides an ideal telephone interface for modem, audio

More information

User s Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394 User s Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,

More information

CYG2111. Cybergate TM DAA INTEGRATED CIRCUITS DIVISION. Description. Features. Applications. Approvals. Ordering Information. Typical Application

CYG2111. Cybergate TM DAA INTEGRATED CIRCUITS DIVISION. Description. Features. Applications. Approvals. Ordering Information. Typical Application Cybergate TM DAA Features Low Distortion Transformer Signal Coupling Complete Ringing Detector Circuit Low Power Hook Switch Electronic Inductor/Gyrator Circuit Surge Protection V.32 bis/v.34 Compatible

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-732 #61-736 400 AAC Clamp Meter Instruction Manual AC HOLD APO DC KMΩ mva WARNING Read First: Safety Information Understand

More information

Part VI: Requirements for ISDN Terminal Equipment

Part VI: Requirements for ISDN Terminal Equipment Issue 9 November 2004 Spectrum Management and Telecommunications Policy Compliance Specification for Terminal Equipment, Terminal Systems, Network Protection Devices, Connection Arrangements and Hearing

More information

CYG20xx. Cybergate TM DAA INTEGRATED CIRCUITS DIVISION. Description. Features. Approvals. Ordering Information. Applications.

CYG20xx. Cybergate TM DAA INTEGRATED CIRCUITS DIVISION. Description. Features. Approvals. Ordering Information. Applications. Cybergate TM DAA Features Low Distortion Transformer Signal Coupling (0.0% max) Complete Ring Detector Circuit Low Power Hook Switch Electronic Inductor/Gyrator Circuit Surge Protection Transient Protection

More information

VOICE AND VOICEBAND DATA CHANNELS

VOICE AND VOICEBAND DATA CHANNELS AT&T Standard PRACTICE SECTION 313-130-100 Issue 1, October 1983 Reprinted July 1984* VOICE AND VOICEBAND DATA CHANNELS CENTRAL OFFICE TRANSMISSION AND SIGNALING TEST S CONTENTS PAGE CONTENTS PAGE 1. GENERAL.......

More information

A Channel Amplifier

A Channel Amplifier Installation Manual A2150 2 Channel Amplifier Table of Contents Installation Requirements and Recommendations 1 What s included 1 Speaker Wire Recommendations 1 Setup 2 Rack Mounting 2 Individually Protected

More information

Far End Device II Model 1342

Far End Device II Model 1342 3 Far End Device II Model 1342 Operating Instructions Optimized for ADSL2+ May 2007 78-8130-0876-6-C Table of Contents Introduction...3 Power-up...4 Connecting the 3M Far End Device II...5 Installing,

More information

Intelligent peripheral equipment circuit cards for New Zealand

Intelligent peripheral equipment circuit cards for New Zealand Meridian 1 Intelligent peripheral equipment circuit cards for New Zealand Option 11 - Description and Installation Document Number: Supplement to 553-3011-210 Document Release: Provisional 1.3 Date: July

More information

AC 1000 Single-Slot T1 Mini Repeater Apparatus Case

AC 1000 Single-Slot T1 Mini Repeater Apparatus Case Telecommunications Group Section AC1 000 00 Equipment Issue Fourth Printing, August 200 AC 1000 Single-Slot T1 Mini Repeater Apparatus Case CLEI Code: T1RCVUFRA CPR: 100 CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

Ambient Level Controller

Ambient Level Controller Ambient Level Controller Installation and Use Manual Issue 1, October 1999 1999 Bogen Communications, Inc. All rights reserved. 54-2028-01 9910 Model: LUALC PEC Code: 5335-621 COM Code: 408184273 Select

More information

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130 User s Guide MultiView Series Digital MultiMeters Models: MV110 MV120 MV130 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year

More information

Distribution Amplifiers 1

Distribution Amplifiers 1 Distribution Amplifiers 1-30dB PUT 49-750 MHz 43 db GA POWER DOUBLED P/N: 1002705 REVERSE GA M MAX DESCRIPTION The R.L. DRAKE models DA8642, DA8632,, and DA7533, are broadband distribution amplifiers designed

More information

Part IV: Glossary of Terms

Part IV: Glossary of Terms Issue 9 November 2004 Spectrum Management and Telecommunications Policy Compliance Specification for Terminal Equipment, Terminal Systems, Network Protection Devices, Connection Arrangements and Hearing

More information

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle. INSTRUCTION MANUAL Model 403380 Autoranging DMM ProbeMeter TM Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle. Back lit LCD with Autorange and full function displays Audible

More information

MULTI-TONE GENERATOR V

MULTI-TONE GENERATOR V PagePac by Issue 1 V-5335500 INTRODUCTION The Multi-Tone Generator (MTG) is a compact, versatile multi-tone generator as well as a Night Bell for a Telephone System. Six different information tones plus

More information

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter USER MANUAL MODEL 2029 Parallel to Serial/ Serial to Parallel Interface Converter C E R T I F I E D An ISO-9001 Certified Company Part #07M2029-B, Rev. C Doc. #102011UB Revised 6/16/09 SALES OFFICE (301)

More information

POT Line to Remote Phone

POT Line to Remote Phone OPX PO Line to Remote Phone FXO In this application the customer uses the specified ADRAN equipment to extend a plain old analog telephone line to a remote location (Off Premise Extension). he customer

More information

Silvertel. Ag1110 LOW COST SLIC

Silvertel. Ag1110 LOW COST SLIC Silvertel V2.7 August 2009 Datasheet LOW COST SLIC FEATURES Single-in-line (SIL) PBX SLIC with integral lead frame. TIP RING PBX SLIC V IN V OUT Highly integrated, requiring a minimum of external components.

More information

Line Signalling Fundamentals

Line Signalling Fundamentals Line Signalling Fundamentals Introduction This document refers to the types of signalling provided by and large by the PRX in its various forms across the range of delivered systems. Some of the concepts

More information

LPF-100 Composite Low Pass Filter

LPF-100 Composite Low Pass Filter Broadcast Devices, Inc. LPF-00 Composite Low Pass Filter TECHNICAL REFERENCE MANUAL Broadcast Devices, Inc. 0 E. Main Street Cortlandt Manor, NY 07 Tel. (94) 77-0 Fax. (94) 7-9 REV: A 0/09 Table of Contents

More information

HydroLynx Systems, Inc.

HydroLynx Systems, Inc. Model 50386R-RP Receiver and Repeater Instruction Manual Document No: A102684 Document Revision Date: August, 2006 Receiving and Unpacking Carefully unpack all components and compare to the packing list.

More information

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz Page 1 of 10 INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK Model LI-4100 10 khz to 10 MHz Page 2 of 10 Table of Contents 1.0 Introduction... 3 2.0 Product Description... 4 3.0 Product Specifications...

More information

PA WATT PORTABLE PA SYSTEM PRODUCT MANUAL

PA WATT PORTABLE PA SYSTEM PRODUCT MANUAL PA-5150 5 150-WATT PORTABLE PA SYSTEM PRODUCT MANUAL THANK YOU FOR CHOOSING POLSEN. The Polsen PA-5150 is an active PA system that s ideal for solo performers or vocalists. It can be used as a PA system

More information

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 3042 (CTS TDM-V.24) Time Division Multiplexor, RS-232 Part #: 07M3042-A Doc #: 119001UA Revised 3/26/01 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION

More information

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH AC/DC LOW CURRENT CLAMP-ON METER CM605 ENGLISH User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments

More information

Model 7000 Low Noise Differential Preamplifier

Model 7000 Low Noise Differential Preamplifier Model 7000 Low Noise Differential Preamplifier Operating Manual Service and Warranty Krohn-Hite Instruments are designed and manufactured in accordance with sound engineering practices and should give

More information

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference Issue 3, October 2002 Electromagnetic Compatibility and Electrical Safety Contents Telcordia GR-1089 - Documentation Information Generic Requirements Notice Of Disclaimer................. iii Contents.......................................

More information

Installation and Operation Manual VC-6A. 6-Channel PCM/ADPCM Voice Module MEGAPLEX-2100 MODULE

Installation and Operation Manual VC-6A. 6-Channel PCM/ADPCM Voice Module MEGAPLEX-2100 MODULE Installation and Operation Manual VC-6A 6-Channel PCM/ADPCM Voice Module MEGAPLEX-2100 MODULE VC-6A 6-Channel PCM/ADPCM Voice Module Installation and Operation Manual Notice This manual contains information

More information

V-136RTHF 36 ZONE TALKBACK INTERCOM/ PAGE CONTROL UNIT

V-136RTHF 36 ZONE TALKBACK INTERCOM/ PAGE CONTROL UNIT VSP-V-13RTHF Issue V-13RTHF 3 ZONE TALKBACK INTERCOM/ PAGE CONTROL UNIT GENERAL The V-13RTHF is a single-path dial select microcomputer controlled intercom and page control unit used with a 1A2 key system

More information

FXO Evaluation Board Technical Brief TN-101

FXO Evaluation Board Technical Brief TN-101 Technical Brief TN-0 Features Provides best-in-class FXO evaluation platform for PBX/telephony gateway systems with fully programmable two-wire impedance capability A complete, integrated board-level solution

More information

Passive Component LCR Meter

Passive Component LCR Meter User's Guide Passive Component LCR Meter Model 380193 LCR M eter 380193 APO AUTO c PAL D 1kHz µ F -0 ENTER L/C/R Q/D/R 1 2 3 RANGE L/C/R Q/D/R 4 5 6 >2sec HOLD MIN MAX SET 7 8 9 REL Hi / Lo LIMITS TOL

More information

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. MANUAL PART NUMBER 180-0036 ORIGINAL: 1-17-83 REVISION: B (8-26-86) NOT TO BE CHANGED WITHOUT MSHA

More information

VC-4, VC-4A, VC-8, VC-8A, VC-16

VC-4, VC-4A, VC-8, VC-8A, VC-16 INSTALLATION AND OPERATION MANUAL VC-4, VC-4A, VC-8, VC-8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules Megaplex-2100/2104 Version 12.9, Megaplex-4100 Version 2.2 VC-4, VC-4A, VC-8, VC-8A, VC-16

More information

Random & Sinusoidal Jitter Injector. Main Unit Operation Manual

Random & Sinusoidal Jitter Injector. Main Unit Operation Manual Random & Sinusoidal Jitter Injector RJI12G Main Unit Operation Manual Rev 1.0 September 2012 Introduction... 2 Safety Instruction... 2 1. General... 4 1 1 Features... 4 1 2 Functions & Characteristics...

More information

AC/DC Current Oscilloscope Probe Model SL261

AC/DC Current Oscilloscope Probe Model SL261 AC/DC Current Oscilloscope Probe Model SL261 USER MANUAL I ZERO 100 mv/a 10 mv/a OFF Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated

More information

Amplified High Speed Photodetectors

Amplified High Speed Photodetectors Amplified High Speed Photodetectors User Guide 3340 Parkland Ct. Traverse City, MI 49686 USA Page 1 of 6 Thank you for purchasing your Amplified High Speed Photodetector from EOT. This user guide will

More information

Model 1791 VHF Radio User's Manual

Model 1791 VHF Radio User's Manual Model 79 VHF Radio User's Manual ALL WEATHER INC 65 NATIONAL DRIVE SACRAMENTO, CA 95834 WWW.ALWEATHERINC.COM 79 VHF RADIO USER'S MANUAL CONTENTS INTRODUCTION... Description... Transmitter Module... Power

More information

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz INSTRUCTION MANUAL CALIBRATED IMPULSE GENERATOR MODEL CIG-25 10 khz 1 GHz INSTRUCTION MANUAL THIS INSTRUCTION MANUAL AND ITS ASSOCIATED INFORMATION IS PROPRIETARY. UNAUTHORIZED REPRODUCTION IS FORBIDDEN.

More information

Active CCTV Receiver Balun Installation Guide

Active CCTV Receiver Balun Installation Guide Active CCTV Receiver Balun 500015 Installation Guide P/N: 94-000304-C SE-000266-C Copyright Notice: Copyright 2009 MuxLab Inc. All rights reserved. Printed in Canada. No part of this publication may be

More information

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual TETRIS 1000 High Impedance Active Probe Instruction Manual Copyright 2015 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL SPECTRADYNAMICS, INC PD5-RM-B PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2. Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 www.spectradynamics.com

More information