1 XA01524D/06/EN/ Products Solutions Services Safety Instructions Proline Promag 500 Cl.I, II, III Div.1 for XP (Ex d Flameproofed version) C US Document: XA01524D Safety instructions for electrical apparatus for explosionhazardous areas classified according to the National Electrical Code (NEC) and Canadian Electrical Code (CEC) 3
2
3 Proline Promag 500 XA01524D Proline Promag 500 Table of contents Associated documentation... 4 Manufacturer's certificates... 4 Extended order code... 4 Safety instructions: General... 8 Safety instructions: Installation... 9 Temperature tables... 9 Connection data: Signal circuits Endress+Hauser 3
4 XA01524D Proline Promag 500 Associated documentation All documentation is available: On the CD-ROM supplied (not included in the delivery for all device versions). Available for all device versions via: Internet: Smart phone/tablet: Endress+Hauser Operations App In the Download Area of the Endress+Hauser web site: Download This document is an integral part of the following Operating Instructions: Measuring device Documentation code HART FOUNDATION Fieldbus PROFIBUS PA Modbus RS485 Promag H 500 BA01398D BA01479D BA01404D BA01401D Promag P 500 BA01399D BA01480D BA01405D BA01402D Promag W 500 BA01400D BA01481D BA01406D BA01403D Additional documentation: Document type Contents Documentation code Control drawing As wanted on the nameplate. Please note the documentation associated with the device. Manufacturer's certificates Certificate number CSA Notified body CSA: Canadian Standards Association Extended order code The extended order code is indicated on the nameplate, which is affixed to the device in such a way that it is clearly visible. Additional information about the nameplate is provided in the associated Operating Instructions. 4 Endress+Hauser
5 Proline Promag 500 XA01524D Structure of the extended order code * * * * * * _ * * * * * * * * * * + A*B*C*D*E*F*G* Device type Basic specifications Optional specifications * = Spaceholder: At this position, an option (number or letter) selected from the specification is displayed instead of the placeholders. Device type The device and the device design is defined in the "Device type" section (Product root). Basic specifications The features that are absolutely essential for the device (mandatory features) are specified in the basic specifications. The number of positions depends on the number of features available. The selected option of a feature can consist of several positions. Optional specifications The optional specifications describe additional features for the device (optional features). The number of positions depends on the number of features available. The features have a 2-digit structure to aid identification (e.g. JA). The first digit (ID) stands for the feature group and consists of a number or a letter (e.g. J = test, certificate). The second digit constitutes the value that stands for the feature within the group (e.g. A = 3.1 material (wetted parts), inspection certificate). More detailed information about the device is provided in the following tables. These tables describe the individual positions and IDs in the extended order code which are relevant to hazardous locations. Device type Position Order code for Option selected Description 1 Instrument family 5 Electromagnetic flowmeter 2 Sensor H, P, W Sensor type 3 Transmitter 5 Transmitter type: 4-wire, compact version 4 Generation index B Platform generation 5, 6 Nominal diameter H: DN 2 to 150 P: DN 15 to 600 W: DN 25 to 2000 Nominal diameter of sensor Endress+Hauser 5
6 XA01524D Proline Promag 500 Proline 500 digital Proline 500 Order code for "Integrated ISEM electronics", option A "Sensor" Order code for "Integrated ISEM electronics", option B "Transmitter" Transmitter 2 Connecting cable 3 Sensor connection housing with integrated ISEM Transmitter with integrated ISEM 2 Coil current cable 3 Signal cable 4 Sensor connection housing Basic specifications Position 1, 2 Order code for "Approval" Option selected Position 10 Order code for "Integrated ISEM electronics" Option selected Type of protection Transmitter Sensor CD B Cl.I, Div.1, Cl.II, III, Gps. A-G Cl.I, Div.1, Cl.II, III Gps. A-G CN A Cl.I, Div.2, Gps. A-D Cl.I, Div.1, Cl.II, III Gps. A-G Item Order code for Option selected Description 4, 5 Output; input 1 BA 4-20mA HART CA GA HA MA SA TA 4-20mA HART Ex-i PROFIBUS PA PROFIBUS PA Ex-i Modbus RS485 FOUNDATION Fieldbus FOUNDATION Fieldbus Ex-i 6 Output; input 2 A W/o; B C 4-20mA 4-20mA Ex-i 6 Endress+Hauser
7 Proline Promag 500 XA01524D Item Order code for Option selected Description D E F G H I J Configurable I/O initial setting off Pulse/freq./switch output Pulse output, phase-shifted Pulse/freq./switch output Ex-i Relay 4-20mA input Status input 7 Output; input 3 A W/o; B C D E F G H I J 4-20mA 4-20mA Ex-i Configurable I/O initial setting off Pulse/freq./switch output Pulse output, phase-shifted Pulse/freq./switch output Ex-i Relay 4-20mA input Status input 8 Output; input 4 1) A W/o; B C D E G H I J 4-20mA 4-20mA Ex-i Configurable I/O initial setting off Pulse/freq./switch output Pulse/freq./switch output Ex-i Relay 4-20mA input Status input 9 Display, Operation F 4-line, illuminated; touch control G 4-line, illuminated; touch control + WLAN 10 Integrated ISEM electronics A Sensor B Transmitter 21, 22 Device model A1 1 1) The order code "Output; input 4" is only available for the Proline 500 digital transmitter. Endress+Hauser 7
8 XA01524D Proline Promag 500 Optional specifications ID Order code for Option selected Description Jx Test, Certificate JN Ambient temperature of measuring device 50 C Safety instructions: General Staff must meet the following conditions for mounting, electrical installation, commissioning and maintenance of the device: Be suitably qualified for their role and the tasks they perform. Be trained in explosion protection. Be familiar with national regulations (e.g. CEC or NEC). Install the device according to the manufacturer's instructions and national regulations. Do not operate the device outside the specified electrical, thermal and mechanical parameters. Only use the device in media to which the wetted materials have sufficient durability. Refer to the temperature tables for the relationship between the permitted ambient temperature for the sensor and/or transmitter, depending on the range of application, and the temperature classes. Modifications to the device can affect the explosion protection and must be carried out by staff authorized to perform such work by Endress+Hauser. When using in hybrid mixtures (gas and dust occurring simultaneously), additional measures should be taken. Please see approval body. Open the device only if one of the following conditions is met: An explosive atmosphere is not present. A waiting time of 10 minutes is observed after switching off the power supply. Observe all the technical data of the device (see nameplate). Class II Group G: The surface temperature of the apparatus cannot exceed +165 C. For transmitter housing "Proline 500 digital" and plastic connection housing of the sensor Promag W, IP68: Avoid electrostatic charging of the housing (e.g. friction, cleaning, maintenance, strong medium flow). LWARNING Substitution of components is not permitted. Substitution of components may impair intrinsic safety. 8 Endress+Hauser
9 Proline Promag 500 XA01524D Safety instructions: Installation Continuous service temperature of the connecting cable: 40 to +80 C( 50 to +80 C for optional specification, ID Jx (Test, Certificate) = JN); but at least according to the service temperature range of the application taking into account additional influences of the process conditions (T a,min and T a,max + 20 K). Only use certified cable entries suitable for the application. Observe selection criteria as per CEC or NEC. When the measuring device is connected, attention must be paid to explosion protection at the transmitter. In potentially explosive atmospheres: Do not disconnect the electrical connection of the power supply circuit when energized. Do not open the connection compartment cover when energized. Install the transmitter circuit wiring according to Canadian Electrical Code (CEC) respective National Electrical Code (NEC) using threaded conduit or other wiring methods in accordance with articles 500 to 510. Transmitter enclosures with XP rating: Enclosures are factory sealed when using in ambient temperature of not lower than -40 C. Sensor enclosures with XP rating: Enclosures are factory sealed. Basic specification, Position 12, order code for "Sensor connection housing", option B, C To protect the housing of stainless steel housings ensure that the housing gasket is flat and not bent when closing the housing cover. Replace bent gaskets. Intrinsic safety Potential equalization Integrate the device into the local potential equalization. If the ground connection has been established via the pipe as specified, it is also possible to integrate the sensor into the potential equalization system via the pipe. Temperature tables Ambient temperature Minimum ambient temperature: T a = 40 C Optional specification, ID Jx (Test, Certificate) = JN Transmitter: T a = 50 C Maximum ambient temperature: T a = +60 C depending on the temperature class: Endress+Hauser 9
10 XA01524D Proline Promag 500 Transmitter Proline 500 digital Non-hazardous area, Zone 2 T a Material transmitter housing Non-hazardous area Aluminum Polycarbonat 60 Transmitter Proline 500 Zone 1 T a Zone 21 Maximum surface temperature at T a = 60 C 85 C Medium temperature Minimum medium temperature: T m = 40 to 0 C depending on the selected device version (see nameplate!) Maximum medium temperature: T m for depending on the maximum ambient temperature T a Proline 500 digital Basic specification, Position 10, order code for "Integrated ISEM electronics", option A 10 Endress+Hauser
11 Proline Promag 500 XA01524D Without thermal insulation Promag H T m PFA Promag P T m PTFE PFA Promag P High-temperature version T m PTFE PFA Promag W T m Hard rubber PU Endress+Hauser 11
12 XA01524D Proline Promag 500 Promag W High-temperature version T m Hard rubber PU Promag P High-temperature version With thermal insulation according to Endress+Hauser specifications For information on the thermal insulation of the device, see the "Thermal insulation" section of the Operating Instructions T m PTFE PFA Promag W High-temperature version T m Hard rubber PU Endress+Hauser
13 Proline Promag 500 XA01524D With thermal insulation without Endress+Hauser specifications 1 A B 1 Position of the reference point for temperature measurement A Standard version B High-temperature version 1 Reference point A Promag P High-temperature version T m, max T m PTFE PFA Promag W High-temperature version T m, max T m Hard rubber PU Proline 500 Basic specification, Position 10, order code for "Integrated ISEM electronics", option B Endress+Hauser 13
14 XA01524D Proline Promag 500 Promag H Without thermal insulation T m PFA Promag P T m PTFE PFA Promag P High-temperature version T m PTFE PFA Promag W T m Hard rubber PU Endress+Hauser
15 Proline Promag 500 XA01524D Promag W High-temperature version T m Hard rubber PU Promag P High-temperature version With thermal insulation according to Endress+Hauser specifications For information on the thermal insulation of the device, see the "Thermal insulation" section of the Operating Instructions T m PTFE PFA Promag W High-temperature version T m Hard rubber PU Endress+Hauser 15
16 XA01524D Proline Promag 500 With thermal insulation without Endress+Hauser specifications 1 A B 2 Position of the reference point for temperature measurement A Standard version B High-temperature version 1 Reference point A Promag P High-temperature version T m, max T m PTFE PFA Promag W High-temperature version T m, max T m Hard rubber PU Endress+Hauser
17 Proline Promag 500 XA01524D Connection data: Signal circuits The following tables contain specifications which are dependent on the transmitter type and its input and output assignment. Compare the following specifications with those on the nameplate of the transmitter. Terminal assignment Transmitter: supply voltage, input/outputs HART Supply voltage (+) 2 ( ) 26 (+) 27 ( ) 24 (+) 25 ( ) 22 (+) 23 ( ) 20 (+) 21 ( ) Device-specific terminal assignment: adhesive label in terminal cover. FOUNDATION Fieldbus Supply voltage (+) 2 ( ) 26 (A) 27 (B) 24 (+) 25 ( ) 22 (+) 23 ( ) 20 (+) 21 ( ) Device-specific terminal assignment: adhesive label in terminal cover. PROFIBUS PA Supply voltage (+) 2 ( ) 26 (B) 27 (A) 24 (+) 25 ( ) 22 (+) 23 ( ) 20 (+) 21 ( ) Device-specific terminal assignment: adhesive label in terminal cover. Modbus RS485 Supply voltage (+) 2 ( ) 26 (B) 27 (A) 24 (+) 25 ( ) 22 (+) 23 ( ) 20 (+) 21 ( ) Device-specific terminal assignment: adhesive label in terminal cover. Endress+Hauser 17
18 XA01524D Proline Promag 500 Safety-related values Order code for "Output; input 1" Option BA Output type Current output 4 to 20 ma HART U N = 30 V Safety-related values "Output; input 1" 26 (+) 27 ( ) Option GA PROFIBUS PA U N = 32 V Option MA Modbus RS485 U N = 30 V Option SA FOUNDATION Fieldbus U N = 32 V Order code for "Output; input 2"; "Output; input 3"; "Output; input 4" Option B Option D Option E Option F Output type Current output 4 to 20 ma User configurable input/output Pulse/frequency/ switch output Double pulse output Output; input 2 24 (+) 25 ( ) U N = 30 V U N = 30 V U N = 30 V U N = 30 V Safety-related values Output; input 3 22 (+) 23 ( ) Output; input 4 1) 20 (+) 21 ( ) Option H Relay output U N = 30 V I N = 100 ma DC/500 ma AC Option I Current input 4 to 20 ma U N = 30 V Option J Status input U N = 30 V 1) The order code "Output; input 4" is only available for the Proline 500 digital transmitter. 18 Endress+Hauser
19 Proline Promag 500 XA01524D Intrinsically safe values Order code for "Output; input 1" Output type Intrinsically safe values "Output; input 1" 26 (+) 27 ( ) Option CA Current output 4-20 ma HART Ex i U i = 30 V l i = 100 ma P i = 1.25 W L i = 0 C i = 0 Option HA PROFIBUS PA Ex i Ex ia 1) U i = 30 V l i = 570 ma P i = 8.5 W L i = 10 µh C i = 5 nf NIFW 2) U i = 32 V l i = 570 ma P i = 8.5 W L i = 10 µh C i = 5 nf Option TA FOUNDATION Fieldbus Ex i Ex ia U i = 30 V l i = 570 ma P i = 8.5 W L i = 10 µh C i = 5 nf NIFW U i = 32 V l i = 570 ma P i = 8.5 W L i = 10 µh C i = 5 nf 1) Only for order code "Approval", Option CD 2) Only for order code "Approval", Option CN Order code for "Output; input 2"; "Output; input 3" "Output; input 4" Option C Option G Output type Current output 4-20 ma Ex i Pulse/frequency/ switch output Ex i Output; input 2 24 (+) Intrinsically safe values 25 ( ) U i = 30 V l i = 100 ma P i = 1.25 W L i = 0 C i = 0 U i = 30 V l i = 100 ma P i = 1.25 W L i = 0 C i = 0 Output; input 3 22 (+) 23 ( ) Output; input 4 1) 20 (+) 21 ( ) 1) The order code "Output; input 4" is only available for the Proline 500 digital transmitter. Endress+Hauser 19
20
Safety Instructions Proline Promass 300
XA01507D/06/EN/01.16 71327925 Products Solutions Services Safety Instructions Proline Promass 300 Class I, Zone 2 AEx/Ex na ic IIC Class I, Zone 2, AEx/Ex na nc ic IIC Class I Division 2 C US Document:
More informationSafety Instructions Proline Promass 100
XA00160D/06/EN/03.14 71261250 Products Solutions Services Safety Instructions Proline Promass 100 Modbus RS485 Cl.I Div.1, Zone 1 for IS (Ex i Intrinsically safe version) C US Document: XA00160D Safety
More informationPROline promag 53 Division 1
XA 040D/06/en/05.01 50099923 FM+SGML 6.0 PROline promag 53 Division 1 Ex Ex documentation for the BA 053D and BA 054D operating instructions according to FACTORY MUTUAL standards documentation for the
More informationProline Promass 40. Safety Instructions. NEPSI Zone 1, Zone 21
Safety Instructions Proline Promass 40 NEPSI Zone 1, Zone 21 This document is an integral part of the following Operating Instructions: BA00061D, Proline Promass 40 HART Contents General warnings.......................................................................
More informationSafety Instructions Micropilot NMR81, NMR84
XA0436G-A/00/EN/0.6 733528 Products Solutions Services Safety Instructions NMR8, NMR84 CA: XP / I / / B,C,D / Tx Ta* IS / I / / A,B,C,D / Tx Ta* I / / Ex db IIC Tx Gb Ta* I / 0 / Ex ia IIC Tx Ga Ta* I
More informationPower supply. Calibration. Surface finishing. Seal. Process connection
Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst
More informationFM Control Drawing Class I Division 2 / Class I Zone 2. Compact version PROMAG 10
Hazardous Locations Class I Div. 2 Groups ABCD or Class I Zone 2 Groups IIC and Class II and III Division 1 Groups EFG W / P / E / H / D / L Notes: 1. Control room equipment shall not use or generate more
More informationProline Promass 83, 84
Safety Instructions Proline Promass 83, 84 NEPSI Zone 1, Zone 21 This document is an integral part of the following Operating Instructions: BA00059D, Proline Promass 83 BA00109D, Proline Promass 84 BA00063D,
More informationProcessMaster, HygienicMaster FEX300, FEX500
SM/FEX300/FEX500/FM/CSA-EN ProcessMaster, HygienicMaster FEX300, FEX500 FM / cfm Div. 1, Div. 2 Safety information for electrical equipment for potentially explosive areas in accordance with Factory Mutual
More informationProcessMaster / HygienicMaster
SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster FM / cfm Div. 1, Div. 2 Safety information for electrical equipment for potentially explosive areas in accordance with Factory Mutual Standards
More informationUser's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R
User's Manual ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 Table of contents Table of contents
More informationSafety Instructions Nivotester FTC625, FTC325
XA01351F-A/00/EN/01.14 71273077 Products Solutions Services Safety Instructions FTC625, FTC325 [Ex ia Ga] IIC/IIB TÜV 13.0903 X Segurança TÜV INMETRO OCP 0004 Document: XA01351F-A Safety instructions for
More informationOPTIWAVE 7300 C Supplementary instructions
OPTIWAVE 7300 C Supplementary instructions Radar (FMCW) Level Transmitter for agitated liquids in process applications Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE 7300 C General
More informationAttachment to Certificate IECEx PTB X
Applicant: Electrical Apparatus: KROHNE Ltd. Measuring converter, type MFC400F Description of equipment The measuring converter, type MFC400F is used as part of a mass flow measuring system to determine
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationFM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationEx instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,
Ex instruction manual Rotamass Coriolis mass flow meter IM 01U10X02-00EN-R_002, 2nd edition, 2016-09-22 Table of contents Table of contents 1 Introduction... 4 1.1 Scope of application... 4 1.2 Applicable
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationDPharp Differential Pressure and Pressure Transmitters
User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change
More informationFLEX Ex Power Supplies
Installation Instructions FLEX Ex Power Supplies (Cat. Nos. 1797-PS2N, -PS2E) About the Power Supplies The power supply is an essential component in the operation of an intrinsically safe system. It must
More informationFLEX Ex V ac In/Quad-Ex dc Out Power Supply
Installation Instructions FLEX Ex 85 250V ac In/Quad-Ex dc Out Power Supply Catalog Number 1797-PS1N Topic Important User Information 2 About the Power Supplies 3 Understand System Planning 4 Electrostatic
More informationATEX Installation Drawings and Instructions
Installation Instructions P/N 20004414, Rev. C September 2008 ATEX Installation Drawings and Instructions For ATEX-approved transmitter installations Note: For hazardous installations in Europe, refer
More informationCoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter
Operating Instruction OI/FCB100/FCH100-EN Rev. D CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter Measurement made easy Change from one to two columns Short product description Coriolis
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationBrief Operating Instructions Proline Promag 50
KA0006D/06/EN/8.6 73439 Products Solutions Services Brief Operating Instructions Proline Promag 50 Electromagnetic flowmeter These Brief Operating Instructions are not intended to replace the Operating
More informationEx instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,
Ex instruction manual Rotamass Coriolis mass flow meter ATEX IM 01U10X01-00EN-R_002, 2nd edition, 2016-09-22 Table of contents Table of contents 1 Language variants of ATEX documentation... 4 2 Introduction...
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More information2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes
More informationFM Safety Manual. Omni-ID UHF Tags
FM Safety Manual Omni-ID UHF Tags This page is intentionally left blank. Document Number 334169 (See Last Page for Revision Details) 2012 Extronics Limited. This document is Copyright Extronics limited.
More informationCompact Orifice Flow Meter
Data Sheet DS/OM Issue 2 Compact Orifice Flow Meter OriMaster Integrated DP Flow measurement system combines primary element with DP Transmitter in a single flowmeter assembly One-piece flowmeter, pressure
More informationSpecial Documentation Levelflex FMP51, FMP52, FMP55, FMP57
SD01328F/00/EN/02.14 71267123 Products Solutions Services Special Documentation Levelflex FMP51, FMP52, FMP55, FMP57 Guided Level Radar Installation and operating instructions for marine approval Levelflex
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationSITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview
Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers
Instruction Manual Supplement DVC6005 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Hazardous Area Approvals and Special Instructions
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT
More informationFlow Measurement SITRANS F M. Flow sensor MAG /49. Overview
Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical
More informationElectromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P
Technical Information TI 049D/06/en 50097005 Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P Flow rate measurement in chemical or process applications Features and benefits
More information4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits Easier commissioning of 5000, 6000, 6000 I All pulsed DC feature a unique SENSORPROM memory unit which stores
More informationATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier
Installation Instructions P/N MMI-20010152, Rev. A June 2007 for Micro Motion CMF400 Sensors with Booster Amplifier For ATEX-approved sensor installations Note: For hazardous installations in Europe, refer
More informationIECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationRosemount 5400 Series Radar Level Transmitter
Radar Level Transmitter Start Step 1: Mount the Transmitter Step 2: Connect the Wiring Step 3: Configure Confirm Configuration End HART 00825-0100-4026I www.rosemount.com 2007 Rosemount Inc. All rights
More informationIntrinsic Safety Control Drawing
s Intrinsic Safety Control Drawing A5E00455287 system in total "No revision to drawing without prior Approval by FM Approvals!" PLC PC Non hazardous area PROFIBUS DP RS 485-IS Coupler PROFIBUS RS 485-IS
More informationExpert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters
Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2411253 Issued to: Balluff Incorporated 8125 Holton Dr Florence, Kentucky 41042 USA Attention: Jim Ramler The products listed below are eligible to bear the CSA Mark
More informationFisher 4200 Series Electronic Position Transmitters
Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationIndumax CLS50/CLS50D. Technical Information
Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D
More informationTechnical Information Proline Prosonic Flow B 200
TI01018D/06/EN/04.15 71310541 Products Solutions Services Technical Information Proline Prosonic Flow B 200 Ultrasonic transit time flowmeter The device for accurate, reliable biogas measurement with loop-powered
More informationBAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description
BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits System information FLO Easier to commission for 5000, 6000, 6000 I All FLO pulsed DC feature a unique SENSORPROM
More informationLoop Powered Indicator
Instruction Manual Model PD686 Loop Powered Indicator M397 January 3, 2019 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Tel: 978-486-9800 Fax: 978-486-0170 PD686 I.S. and N.I. NEMA 4X, IP67
More informationOPTISONIC Ultrasonic flowmeter for liquids in all industrial applications
OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature
More informationProline Prosonic Flow B 200
Technical Information Proline Prosonic Flow B 200 Ultrasonic flow measuring system The device for accurate, reliable biogas measurement under variable process conditions Application Reliable measurement
More informationSITRANS LR 300: High Performance Radar for Level Measurement
SITRANS LR 300: High Performance Radar for Level Measurement Reliable Measurement In Extreme Conditions SITRANS LR 300 delivers high performance level measurement at an affordable price for the chemical,
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More information1-830 SERIES DISPLACEMENT TRANSMITTER
1-830 SERIES DISPLACEMENT TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationResistance Thermometers Model Series TR7X0, Sheathed Design
Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70163240 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, Bayern 63911 GERMANY Attention: Harald Gollas The products listed
More informationUser's Manual Model SE14 Magnetic Flow Converter
User's Manual Model SE14 Magnetic Flow Converter Manual Change No. 09-001-6E Please use attached sheets for the pages listed below in (7th). Page Page 10-2 EMC Conformity Standards Contents Changed the
More informationJM Enclosure Dimensions (in mm)
ub #0revB process networking solutions Junction Module (JM ) Enclosure with: FOUNDATION Fieldbus Input/Output Module (JMM9 ) These I/O Modules are designed to function as FOUNDATION Fieldbus nodes with
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationIP26 Series Current to Pneumatic Converter
Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear
More informationICARUS ELECTRONIC GAS VOLUME CONVERTER
ICARUS ELECTRONIC GAS VOLUME CONVERTER 1. INTRODUCTION 2. TECHNICAL DETAILS ICARUS is an electronic volume converter which, combined with a gas meter, provides the gas measurement in Sm3, calculated at
More informationPage 1 of 5 Attachment to IECEx TUN X Issue 0
Page 1 of 5 IECEx TR: File reference: DE/TUN/ExTR12.0022/00 12 217 098526 IECEx QAR: File reference: DE/QAR/TUN/06.0002/04 QAR TUN 04.0002 The microwave sensors type series VEGAFLEX FX8*(*).*D****A/H/B/I/U*****
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL
More informationTechnical Information CNGmass DCI
TI00098D/06/EN/14.16 71316735 Products Solutions Services Technical Information CNGmass DCI Coriolis flowmeter The refueling application flowmeter with seamless system integration Application Measuring
More informationWhite Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005
White Paper Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment March 24, 2005 up Königsberger Allee 87 68307 Mannheim Germany Tel. + 49 621 776-0 Fax +49
More informationDescription of equipment
Applicant: Electrical Apparatus: KROHNE Messtechnik GmbH & Co. KG Level Radar BM 70M-Ex Description of equipment The Types BM 70M-Ex Level Radar gauges serve to continuously measure the product level in
More informationFor use in Flammable Gas and Dust Atmospheres
ISTRUCTIO MAUA (ATEX) BExCBG0505D Flameproof Combined / For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExCBG0505D is a second generation flameproof combined beacon / beacon which is
More informationIsolators A3/1.
> Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]
More informationPressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751
060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationRosemount 5408 and 5408:SIS Level Transmitters
Quick Start Guide 00825-0100-4408, Rev AD March 2018 Rosemount 5408 and 5408:SIS Level Transmitters Cone Antenna Quick Start Guide March 2018 1 About this guide This Quick Start Guide provides basic guidelines
More informationCondumax CLS15 and CLS15D
Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationOriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple
Data sheet DS/FPD500 EN Rev. E OriMaster FPD500 Compact orifice flowmeter Orifice-based flow metering made simple Integrated DP flow measurement system, pressure tested as an assembly combines primary
More informationINTRINSIC SAFETY BASIC PRINCIPLES
INTRINSIC SAFETY BASIC PRINCIPLES IGNITION TRIANGLE Ignition Energy In many industrial processes, the presence of flammable materials (gases, vapours, liquids, dusts, fibres and flyings) requires the adoption
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationTransit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P
Technical Information TI 056D/24/ae Transit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P Volume flow measurement of liquids in chemical or process applications Features and benefits
More informationIntrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationArmstrong Intelligent Monitoring Installation and Operation Manual
Armstrong Intelligent Monitoring Installation and Operation Manual Models: AD5000, ST5700, TD5100 IOM-256-B Please read and save these instructions Installation and Set Up Overview Warning: Lithium Batteries
More informationIntroduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter
Field Intelligent Device Series Electromagnetic Flowmeter Converter LF620,LF622 Introduction Combined with a multi-functional converter LF620 (combined type) or LF622 (separate type) equipped with its
More informationIndustrial Pressure Transducers
Industrial Pressure Transducers User s Manual T Model T Model The Swagelok T model transducer is engineered for use in industrial pressure measurement applications where intrinsically safe ratings are
More informationInstruction. MI October I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams
Instruction MI 019-175 October 2000 I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams MI 019-175 October 2000 Intrinsically Safe Connection Diagrams If your Model 83.-D/-T
More informationTechnical Information LPGmass
TI00080D/06/EN/14.15 71240750 Products Solutions Services Technical Information LPGmass Coriolis flowmeter The refueling and distribution application flowmeter with easy system integration Application
More informationServo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.
Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell Enraf s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationSignal converter for electromagnetic flowmeters
IFC 100 Quick Start Signal converter for electromagnetic flowmeters Electronic revision: ER 3.1.2_ The documentation is only complete when used in combination with the relevant documentation for the flow
More informationModel 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet
Product Data Sheet 00813-0101-4796 Model 144H PC-Programmable Temperature Transmitter FEATURES Configurable using the Model 144C Configuration Interface hardware and software Programmable via standard
More informationSingle-Channel Safety Barriers Series 9001
Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More information3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.
Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More information