Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter

Size: px
Start display at page:

Download "Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter"

Transcription

1 Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter D E S C R I P T I O N The Eclipse Model 706 High Performance Transmitter is a loop-powered, 24 VDC level transmitter that is based upon the proven and accepted technology of Guided Wave Radar (GWR). Encompassing a number of significant engineering accomplishments, this leading edge level transmitter is designed to provide measurement performance well beyond that of many of the more traditional technologies. Measures Level, Interface, Volume, and Flow Utilizing diode switching technology, along with the most comprehensive probe offering on the market, this single transmitter can be used in a wide variety of applications ranging from very light hydrocarbons to waterbased media. The innovative angled, dual compartment enclosure is now a common sight in the industry. This enclosure, first brought to the industry by Magnetrol in 1998, is angled to maximize ease of wiring, configuration, and viewing of the versatile graphic LCD display. One universal Model 706 transmitter can be used and interchanged with all probe types, and offers enhanced reliability as it is certified for use in critical SIL 2 hardware safety loops. The ECLIPSE Model 706 supports both the FDT/DTM and Enhanced DD (EDDL) standards, which allow viewing of valuable configuration and diagnostic information such as the echo curve in tools such as PACTware, AMS Device Manager, and various HART Field Communicators. A P P L I C A T I O N S MEDIA: Liquids, solids, or slurries; hydrocarbons to waterbased media (Dielectric Constant ε r = ) VESSELS: Most process or storage vessels up to rated probe temperature and pressure. Eclipse Model 706 DTM CONDITIONS: All level measurement and control applications including process conditions exhibiting visible vapors, foam, surface agitation, bubbling or boiling, high fill/empty rates, low level and varying dielectric media or specific gravity.

2 F E A T U R E S Multivariable, two-wire, 24 VDC loop-powered transmitter for level, interface, volume, or flow. Diode switching technology offers best-in-class signal strength and signal-to-noise ratio (SNR) resulting in enhanced capability in difficult low dielectric applications. Level measurement not affected by changing media characteristics. No need to move levels for calibration. Overfill Capable probes allow for true level measurement all the way up to the process seal, without the need for special algorithms. 4-button keypad and graphic LCD display allow for convenient viewing of configuration parameters and echo curve. Proactive diagnostics advise not only what is wrong, but also offer troubleshooting tips. Nine common tank shapes for volumetric output. 30-point custom strapping table for uncommonlyshaped tanks. Two standard flumes and four standard weirs of various sizes for flow measurement. Generic flow equation for non-standard channels. 360 rotatable housing can be separated from probe without depressurizing the vessel. Probe designs up to +850 F/6250 psi (+450 C/431 bar). Saturated steam applications up to 3000 psi (207 bar), +750 F (+400 C) when installed in side-mounted chamber. Cryogenic applications down to -320 F (-196 C). Transmitter can be remote-mounted up to 12 feet (3.6 m) away from the probe. FMEDA certification allows use in SIL 2 Loops No moving parts. FOUNDATION fieldbus and Modbus digital outputs. T E C H N O L O G Y P R I N C I P L E O F O P E R A T I O N ECLIPSE Guided Wave Radar is based upon the technology of TDR (Time Domain Reflectometry). TDR utilizes pulses of electromagnetic energy transmitted down a wave guide (probe). When a pulse reaches a surface that has a higher dielectric constant than the air (ε r = 1) in which it is traveling, a portion of the pulse is reflected. The transit time of the pulse is then measured via high speed timing circuitry that provides an accurate measure of the liquid (or solids) level. The amplitude of the reflection depends on the dielectric constant of the product. The higher the dielectric constant, the larger is the reflection. Reflected Pulse Initial Pulse Air ε r = 1 Liquid ε r > 1.2 Transmitted Pulse Overall Liquid Level Reflected Pulse Initial Pulse Air ε r = 1 ε r > 1.2 Transmitted Pulse Bulk Solid Level I N T E R F A C E M E A S U R E M E N T The ECLIPSE Model 706 is capable of measuring both an upper liquid level and an interface liquid level. As only a portion of the pulse is reflected from a low dielectric upper surface, some of the transmitted energy continues down the GWR probe through the upper liquid. The remaining initial pulse is again reflected when it reaches the higher dielectric lower liquid. It is required that the upper liquid has a dielectric constant less than 10, and the lower liquid has a dielectric constant greater than 15. A typical interface application would be oil over water, with the upper layer of oil being non-conductive (ε r 2.0), and the lower layer of water being very conductive (ε r 80). The thickness of the upper layer could be as small as 2" (50 mm) while the maximum upper layer is limited to the length of the GWR probe. 2 Upper level signal Interface level signal Time Reference Signal Interface Level Air ε r = 1 Low dielectric medium (e.g. oil, ε r = 2) Emulsion High dielectric medium (e.g. water, ε r = 80)

3 S P E C I A L A P P L I C A T I O N S E M U L S I O N L A Y E R S As emulsion layers, also called rag layers, can decrease the strength of the reflected signal in an interface application, GWR transmitters are typically recommended for applications that have clean, distinct layers. However, the ECLIPSE Model 706, with its powerful internal measurement algorithms, will tend to detect the top of an emulsion layer. Contact the factory for application assistance regarding emulsion layers in your specific application. SATURATED STEAM APPLICATIONS ( B o i l e r s, F e e d w a t e r H e a t e r s, e t c. ) As the temperature of a saturated steam application increases, the dielectric constant of the steam vapor space also increases. This increase in vapor space dielectric causes a delay in the GWR signal propagation as it travels down the probe, causing the liquid level to appear lower than actual. The ECLIPSE Model 706 transmitter and Model 7yS Coaxial Steam probe provide a unique solution to this application. The effects of the changing steam conditions can be compensated for by utilizing a mechanical steam target placed inside and near the top of the Model 7yS coaxial probe. NOTE: The measurement error associated with this propagation delay does depend on temperature and is a function of the square root of the vapor space dielectric constant. For example, with no compensation, a +450 F (+230 C) application would show a level error of about 5.5%, while a +600 F (+315 C) application would show an error approaching 20%! O V E R F I L L C A P A B I L I T Y Although agencies like WHG or VLAREM certify Overfill proof protection, defined as the tested, reliable operation when the transmitter is used as overfill alarm, it is assumed in their analysis that the installation is designed in such a way that the vessel or side mounted cage cannot physically overfill. However, there are practical applications where a GWR probe can be completely flooded with level all the way up to the process connection (face of the flange). Although the affected areas are application dependent, typical GWR probes have a transition zone (or possibly dead zone) at the top of the probe where interacting signals can either affect the linearity of the measurement or, more dramatically, result in a complete loss of signal. While some manufacturers of GWR transmitters may use special algorithms to infer level measurement when this undesirable signal interaction occurs and the actual level signal is lost, the ECLIPSE Model 706 offers a unique solution by utilizing a concept called Overfill Safe Operation. An Overfill safe probe is defined by the fact that it has a predictable and uniform characteristic impedance all the way down the entire length of the waveguide (probe). These probes allow the ECLIPSE Model 706 to measure accurate levels up to the process flange without any nonmeasurable zone at the top of the GWR probe. Overfill safe GWR probes are unique to ECLIPSE GWR, and coaxial probes can be installed at any location on the vessel. Overfill safe probes are offered in a variety of Coaxial and Caged designs. Knowing exactly where the target is located at room temperature, and then continuously monitoring its apparent location, the vapor space dielectric can be back-calculated. Knowing the vapor space dielectric, accurate compensation of the actual liquid level reading is accomplished. This is a patented technique with two US Patents (US and US ) issued for both the mechanical target concept and the associated software algorithm. Contact the factory for additional information relating to saturated steam applications. 3

4 P R O B E O V E R V I E W T H R E E S T Y L E S O F G W R P R O B E S With one basic ECLIPSE Model 706 transmitter that operates with all probes, choosing the proper Guided Wave Radar (GWR) probe is the most important decision in the application process. The probe configuration establishes fundamental performance characteristics. All ECLIPSE Model 706 probes can be described by three basic configurations: Coaxial Twin flexible cable Single element (rigid rod or flexible cable) Each of these probe configurations has specific strengths and weaknesses. Although there can be overlap, and different probes can certainly be used in similar applications, it is important to understand their basic differences so that one can choose the probe type that will offer optimal performance. The descriptions below are facts relating to the physics of GWR technology and are not specific to the ECLIPSE Model 706. C O A X I A L P R O B E S The coaxial probe is the most efficient of all GWR probe configurations and should be the first consideration in all applications. Analogous to the efficiency of coaxial cable, a coaxial probe allows almost unimpeded movement of the high frequency pulses throughout its length. The electromagnetic field that develops between the inner rod and outer tube is completely contained and uniform down the entire length of the probe. See Figure 1. This means that the coaxial probe is immune to any proximity affects from other objects in the vessel, and therefore, in essence, it can be used anywhere that it can mechanically fit. The efficiency and overall sensitivity of a coaxial configuration yields robust signal strength, even in extremely low dielectric (ε r 1.4) applications. The sensitivity of this closed design, however, also makes it more susceptible to measurement error in applications that can have coating and buildup. All ECLIPSE Model 706 coaxial probes are Overfill Safe as standard, by design. Figure 1 Coaxial Probe B A S I C F O R C L E A N L I Q U I D S The basic 0.875" (22.5 mm) diameter coaxial GWR probe is only recommended for use in clean applications or special applications such as saturated steam. Teflon, PEEK, or alumina spacers centering the inner rod within the outer tube are located at 24" (60 cm) intervals, resulting in a perfect characteristic impedance along the entire length of the probe. This probe is recommended in applications with viscosities up to 500 cp (mpa.s) maximum. ENLARGED FOR DIFFICULT LIQUIDS The standard Enlarged 1.75" (45 mm) or 1.93 (49mm) diameter coaxial GWR probes can be generally used for most applications. They can be installed directly into the tank as well as into bypass cages, stillwells or bridles. The robust construction reduces the number of spacers required, allowing the probe to be used in applications where higher risk of buildup exists. To further reduce the possibility of media buildup, the use of a single bottom spacer is recommended up to probe lengths of 100 inches (2.54 meters). The overall sensitivity and performance of an enlarged coaxial GWR probe is identical to a standard coaxial GWR probe, but it offers the very important advantage that it can be used in applications with viscosities up to 2,000 cp (mpa.s). 4

5 P R O B E O V E R V I E W C O N T I N U E D T H R E E S T Y L E S O F G W R P R O B E S O P T I O N A L F L U S H I N G C O N N E C T I O N The maintenance of coaxial GWR probes in applications suffering from buildup or crystallization can be significantly improved by using an optional flushing connection. This flushing connection is a metal extension with a port welded above the process connection. The port allows the user to purge the inside of the coaxial GWR probe during routine maintenance. Note: The best approach to eliminate the effects of condensation or crystallization is to install adequate insulation or heat tracing (steam or electrical). A flushing connection is no substitute for proper maintenance, but will help to reduce the frequency of the intervention. Flushing Port Shown Plugged ( 1 4" NPT-F) C A G E D F O R D I R T Y L I Q U I D S Unique to MAGNETROL, the Caged GWR probe is a single rod probe which uses an existing or new cage, bridle, or stillwell as the second conductor to re-create the same signal propagation as a coaxial GWR probe. Caged GWR probes are designed for 2" (DN50), 3" (DN80) or 4" (DN100) diameter metal chambers, and utilize a specially designed impedance matching section that results in the same overall characteristic impedance of a coaxial style GWR probe. Caged GWR probes offer the same sensitivity and performance as coaxial GWR probes, but the single conductor design allows it to be used in applications with viscosities up to 10,000 cp (mpa.s). O P T I O N A L A N N U N C I A T O R F I T T I N G High Pressure and High Temperature High Pressure ECLIPSE Model 706 probes containing a glass ceramic alloy process seal (Models 7yD, P, J, L, M and N) are available with an optional annunciator fitting. The use of this fitting complies with the Dual Seal requirements of ANSI/ISA , titled Requirements for Process Sealing between Electrical Systems and Flammable or Combustible Process Fluids, which require the incorporation of a method that indicates or annunciates a primary seal failure (e.g., visible leakage, an audible whistle, or other means of monitoring). 5

6 P R O B E O V E R V I E W C O N T I N U E D T H R E E S T Y L E S O F G W R P R O B E S T W I N C A B L E F L E X I B L E P R O B E S The relationship of the Twin Cable probe design to a coaxial probe design is similar to that of older, twin-lead, antenna lead-in to modern, coaxial cable. 300-ohm twinlead cable simply does not have the efficiency of 75-ohm coaxial cable, making the parallel conductor design less sensitive than the concentric coaxial. See Figure 2. This translates into Twin Cable GWR probes having the ability to measure dielectrics down to ε r 1.7. Heavy bridging of material between the cables across the FEP coating can cause improper measurement and should be avoided. Figure 2 also shows that, although most of the electromagnetic field develops between the two cables, there is also some peripheral energy that expands outward, making the Twin Cable probe more sensitive to proximity effects of objects located immediately around it. For that reason, it is recommended to keep the active element of the Twin Cable probe at least 1 inch (25 mm) away from metal objects. Figure 2 Twin Flexible Probe S I N G L E R O D P R O B E S Single element GWR probes act quite differently than both coaxial and twin cable designs. With only one conductor to work with, the pulses of energy develop between the single rod probe and the mounting nut or flange. In other words, the pulse propagates down and around the rod as it references its ground at the top of the tank. The energy and efficiency of the pulse are directly related to how much metallic surface exists around it at the top of the vessel. This metallic surface at the top of the probe is called the launch plate. The larger the launch plate, the more efficient the signal propagation down the probe. Figure 3 shows the single element design and how the electromagnetic pulse effectively expands into a teardrop shape as it propagates away from the top of the tank (the inherent ground reference). This single element configuration (rod or cable) is the least efficient of the three probe types, but can still operate with a minimum dielectric detection of approximately ε r > 1.7 in an open, nonmetallic vessel. However, this dielectric constant performance improves considerably (ε r > 1.4) when the single rod probe is installed in a metal cage/bridle, or mounted 2 6" ( mm) away from a metal tank wall. Because the design is open, it exhibits two strong tendencies: It is the most forgiving of coating and buildup. (The PFA-insulated probe is the best choice for severe buildup and coating). It is most affected by proximity issues. It is important to note that a parallel metal wall INCREASES the performance of a single rod probe while a singular, metal object protruding out near the probe may be improperly detected as a liquid level. These tendencies are application/installation dependent. Therefore, by properly matching the single rod probe to a cage/chamber, the ECLIPSE Model 706 broad offering of caged probes combines the performance/sensitivity advantages of a coaxial probe and the viscosity immunity of a single rod probe. The Caged Probes are Overfill Safe by design, can be used in interface and other difficult, low dielectric applications, and are unique to MAGNETROL and the ECLIPSE Model 706. Contact the factory for additional support and questions. Figure 3 Single Rod Probe Launch Plate 6

7 P R O B E S E L E C T I O N G U I D E COAXIAL/CAGED GWR PROBE TWIN CABLE GWR PROBE SINGLE ROD/CABLE PROBE signal propagation signal propagation signal propagation end view end view La GWR Probe Description Application Installation Dielectric Range Temperature Range Max. Overfill Vacuum ƒ Pressure Safe Viscosity cp (mpa.s) 7yT 7yP 7yD 7yS 7yG 7yL 7yJ Coaxial GWR Probes Liquids Standard Temperature Level/Interface Tank/Chamber ε r to +400 F 1000 psi (-40 to +200 C) (70 bar) High Pressure Level/Interface Tank/Chamber ε r to +400 F (-196 to +200 C) 6250 psi (431 bar) High Temp./ High Press. Level/Interface Tank/Chamber ε r to +850 F (-196 to +450 C) 6250 psi (431 bar) Steam Probe Saturated Steam Tank/Chamber ε r to +750 F (-40 to +400 C) 3000 psi (207 bar) Caged GWR Probes Liquids Standard Temperature Level/Interface Chamber ε r to +400 F 1000 psi (-40 to +200 C) (70 bar) High Pressure Level/Interface Chamber ε r to +400 F (-196 to +200 C) 6250 psi (431 bar) High Temp./ High Press. Level/Interface Chamber ε r to +850 F (-196 to +450 C) 6250 psi (431 bar) Yes Yes 500/2000 Full Yes 500/2000 Full Yes 500/2000 Full No 500 Yes Yes Full Yes Full Yes yF 7yM 7yN Standard Temperature High Pressure High Temp./ High Press. Single Rod Rigid GWR Probes Liquids Level Tank ε r to +400 F 1000 psi (-40 to +200 C) (70 bar) Level Tank ε r to +400 F (-196 to +200 C) 6250 psi (431 bar) Level Tank ε r to +850 F (-196 to +450 C) 6250 psi (431 bar) Yes No «10000 Full No «10000 Full No « y1 7y3 7y4➈ 7y6 7y7 Single Cable Flexible GWR Probes Liquids Standard Temperature Level Tank ε r to +400 F 1000 psi (-40 to +200 C) (70 bar) High Pressure Level Tank ε r to +400 F 6250 psi (-196 to +200 C) (431 bar) Standard Temperature Level/Interface Chamber ε r to +400 F 1000 psi (-40 to +200 C) (70 bar) High Temp./ High Press Level/Interface Chamber ε r to +850 F 6250 psi (-196 to +450 C) (431 bar) Twin Cable Flexible GWR Probes Liquids Standard Temperature Level/Interface Tank ε r to +400 F 1000 psi (-40 to +200 C) (70 bar) Yes No «10000 Full No «10000 Yes No «10000 Full No «10000 Yes No «1500 7y2 Bulk Solids Probe Single Cable Flexible GWR Probes Solids Level Tank ε r to +150 F (-40 to +65 C) Atmos. No No « y5 Bulk Solids Probe Twin Cable Flexible GWR Probes Solids Level Tank ε r to +150 F (-40 to +65 C) Atmos. No No « nd digit A=English, C=Metric Minimum ε r 1.2 with end of probe analysis enabled. Single rod probes mounted directly into the vessel must be within 3 6 inches of metal tank wall to obtain minimum dielectric of 1.4, otherwise ε r min = 1.7. Depends on the probe spacer material. Refer to Model Selection for spacer options. ƒ ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seals are hermetically sealed to < atmosphere helium. When installed in side-mounted chamber. Consult factory for overfill applications. «Overfill capability can be achieved with software. ➈ Scheduled for future release. 7

8 T R A N S M I T T E R S P E C I F I C A T I O N S F U N C T I O N A L / P H Y S I C A L System Design Measurement Principle Guided Wave Radar based on Time Domain Reflectometry (TDR) Input Measured Variable Level, as determined by GWR time of flight Span 6 inches to 100 feet (15 cm to 30 m); Model 7yS Probe 20 feet (610 cm) max. Output Type 4 to 20 ma with HART: 3.8 ma to 20.5 ma useable (per NAMUR NE43) FOUNDATION fieldbus : H1 (ITK Ver ) Modbus Resolution Analog:.003 ma Digital Display: 1 mm Loop Resistance VDC and 22 ma Diagnostic Alarm Selectable: 3.6 ma, 22 ma (meets requirements of NAMUR NE 43), or HOLD last output Diagnostic Indication Meets requirements of NAMUR NE107 Damping Adjustable 0 10 seconds User Interface Keypad 4-button menu-driven data entry Display Graphic liquid crystal display Digital Communication/Systems HART Version 7 with Field Communicator, FOUNDATION fieldbus, AMS, or FDT DTM (PACTware ), EDDL Menu Languages Transmitter LCD: English, French, German, Spanish, Russian HART DD: English, French, German, Spanish, Russian, Chinese, Portuguese FOUNDATION fieldbus and Modbus Host System: English Power (at transmitter terminals) HART: General Purpose (Weatherproof)/Intrinsically Safe/Explosion-proof: 16 to 36 VDC 11 VDC minimum under certain conditions (refer to I&O Manual ) FOUNDATION fieldbus: 9 to 17.5 VDC FISCO ia / FNICO ic, Explosion Proof, General Purpose and Weatherproof Modbus: 8 to 30 VDC Explosion Proof, General Purpose, and Weatherproof Housing Material IP67/die-cast aluminum A413 (<0.4% copper); optional stainless steel Net/Gross Weight Aluminum: 4.5 lbs. (2.0 kg) Stainless Steel: 10.0 lbs. (4.50 kg) Overall Dimensions H 8.34" (212 mm) x W 4.03" (102 mm) x D 7.56" (192 mm) Cable Entry 1 2" NPT or M20 SIL 2 Hardware (Safety Integrity Level) Safe Failure Fraction = 93% (HART only) Functional Safety to SIL 2 as 1oo1 in accordance with IEC

9 T R A N S M I T T E R S P E C I F I C A T I O N S F U N C T I O N A L / P H Y S I C A L C O N T I N U E D Environment Operating Temperature -40 to +175 F (-40 to +80 C); LCD viewable -5 to +160 F (-20 to +70 C) Storage Temperature -50 to +185 F (-45 to +85 C) Humidity 0 to 99%, non-condensing Electromagnetic Compatibility Meets CE requirement (EN 61326) and NAMUR NE 21 NOTE: Single Rod and Twin Cable probes must be used in metallic vessel or stillwell to maintain CE noise immunity Surge Protection Meets CE EN (1000V) Shock/Vibration ANSI/ISA-S71.03 Class SA1 (Shock); ANSI/ISA-S71.03 Class VC2 (Vibration) Performance Reference Conditions Reflection from liquid, with dielectric constant in center of selected range, with a 72" (1.8 m) coaxial probe at +70 F (+20 C), in Auto Threshold Mode Linearity Coaxial/Caged Probes: <0.1% of probe length or 0.1 inch (2.5 mm), whichever is greater Single Rod in Tanks/Twin Cable: <0.3% of probe length or 0.3 inch (7.5 mm), whichever is greater Accuracy Coaxial/Caged Probes: ±0.1% of probe length or ±0.1 inch (2.5 mm), whichever is greater Single Rod in Tanks/Twin Cable: ±0.5% of probe length or ±0.5 inch (13 mm), whichever is greater Interface Operation: Coaxial/Caged probes: ±1 inch (25 mm) for an interface thickness greater than 2 inches (50 mm) Twin Flexible probes: ±2 inch (50 mm) for an interface thickness greater than 8 inches (200 mm) Resolution ±0.1 inch or 1 mm Repeatability <0.1 inch (2.5 mm) Hysteresis <0.1 inch (2.5 mm) Response Time Approximately 1 second Initialization Time Less than 10 seconds Ambient Temperature Effect Approx. ±0.02% of probe length/degree C (for probes greater than 8 feet (2.5 m)) Process Dielectric <0.3 inch (7.5 mm) within selected range FOUNDATION fieldbus ITK Version H1 Device Class Link Master (LAS) selectable ON/OFF H1 Profile Class 31PS, 32L Function Blocks (8) Al, (3) Transducer, (1) Resource, (1) Arithmetic, (1) Input Selector, (1) Signal Characterizer, (2) PID, (1) Integrator Quiescent Current 15 ma Execution Time 15 ms (40 ms PID Block) Device Revision 02 DD Version 0x01 Modbus Power Consumption <0.5W Signal Wiring Two-wire half duplex RS-485 Modbus Ground (common mode) Voltage ±7V Bus Termination Per EIA-485 Specifications will degrade in Fixed Threshold mode. Linearity in top 18 inches (46 cm) of Twin Cable and Single Rod probes in tanks will be application dependent. Accuracy may degrade when using manual or automatic compensation. 9

10 C O A X I A L P R O B E M A T R I X 7yT 7yP Description Standard Temperature High Pressure Application Level/Interface Level/Interface Installation Tank/Chamber Tank/Chamber Overfill Safe Yes Yes Materials Probe 316/316L (1.4401/1.4404) Hastelloy C (2.4819) Monel (2.4360) 316/316L (1.4401/1.4404) Hastelloy C (2.4819) Monel (2.4360) Process Seal Teflon TFE with Viton o-rings Hermetic Glass Ceramic, Inconel Spacers Teflon TFE Teflon TFE Probe Outside Diameter Enlarged Basic 316 SS: 1.75" (45 mm) Hastelloy: 1.90" (49 mm) Monel: 1.90" (49 mm) 0.87" (22.5 mm) 316 SS: 1.75" (45 mm) Hastelloy: 1.90" (49 mm) Monel: 1.90" (49 mm) 0.87" (22.5 mm) Process Connection Threaded Flanged Available Probe Length Standard Enlarged Enlarged 2" NPT ( 3 4" NPT or 1" BSP) Various ANSI, EN1092, and proprietary flanges 12 to 240 inches (30 to 610 cm) 30 feet (9 m) max. segmented Enlarged 2" NPT ( 3 4" NPT or 1" BSP) Various ANSI, EN1092, and proprietary flanges 12 to 240 inches (30 to 610 cm) 30 feet (9 m) max. segmented Transition Zones Top Bottom 0 inches (0 mm) ε r = 1.4: 6 inches (150 mm) ƒ, ε r = 80: 2 inches (50 mm) 0 inches (0 mm) ε r = 1.4: 6 inches (150 mm) ƒ, ε r = 80: 2 inches (50 mm) Process Temperature -40 to +400 F (-40 to +200 C) -320 to +400 F (-196 to +200 C) Max. Process Pressure F ( C) F ( C) Dielectric Range 1.4 to to 100 Vacuum Service Negative Pressure, Full Vacuum but no hermetic seal Viscosity Enlarged Basic 2000cP (mpa.s) 500cP (mpa.s) 2000cP (mpa.s) 500cP (mpa.s) Media Coating Filming Filming Other o-ring materials available upon request. Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. Refer to chart on page 16. ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed to < atmosphere helium. ƒ Can be reduced to 3" (75 mm) when lower accuracy is acceptable. 1.2 minimum dielectric when end of probe analysis is enabled. 10

11 C O A X I A L P R O B E M A T R I X C O N T I N U E D 7yD 7yS Description High Temp./High Pressure Steam Probe Application Level/Interface Saturated Steam Installation Tank/Chamber Tank/Chamber Overfill Safe Yes No Materials Probe 316/316L (1.4401/1.4404) Hastelloy C (2.4819) Monel (2.4360) 316/316L (1.4401/1.4404) Hastelloy C (2.4819) Process Seal Hermetic Glass Ceramic, Inconel Hermetic Glass Ceramic, PEEK HT, Inconel Spacers PEEK HT/Ceramic PEEK HT/Ceramic Probe Outside Diameter Enlarged Basic HIgh-Temp Model 7YS 316 SS: 1.75" (45 mm) Hastelloy: 1.92" (49 mm) Monel: 1.92" (49 mm) 0.87" (22.5 mm) N/A N/A 0.87" (22.5 mm) 1.25" (31.8 mm) Process Connection Threaded Flanged 2" NPT or 2" BSP Various ANSI, EN1092, and proprietary flanges 3 4" NPT or 1" BSP Various ANSI, EN1092, and proprietary flanges Available Probe Length Standard Enlarged 12 to 240 inches (30 to 610 cm) 30 feet (9 m) max. segmented 24 to 240 inches (60 to 610 cm) N/A Transition Zones Top Bottom 0 inches (0 mm) ε r = 1.4: 6 inches (150 mm), ε r = 80: 2 inches (50 mm) 8 inches (200 mm) ε r = 80: 2 inches (50 mm) Process Temperature -320 to +850 F (-196 to 450 C) -58 to +750 F (-50 to +400 C) «Max. Process Pressure F ( C) 3000 psi (207 bar) Dielectric Range 1.4 to 100 ƒ 10 to 100 Vacuum Service Full Vacuum Full Vacuum Viscosity Enlarged Basic 2000cP (mpa.s) 500cP (mpa.s) N/A 500cP (mpa.s) Media Coating Filming Filming Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. Refer to chart on page 16. ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed to < atmosphere helium. Can be reduced to 3" (75 mm) when lower accuracy is acceptable. ƒ 1.2 minimum dielectric when end of probe analysis is enabled. Consult factory for overfill applications. Not available with +650 F (+345 C) version of the 7yS probe. «When installed in side-mounted chamber. 11

12 C A G E D P R O B E M A T R I X 7yG 7yL 7yJ Description Standard Temperature High Pressure High Temp./High Pressure Application Level/Interface Level/Interface Level/Interface Installation Chamber Chamber Chamber Overfill Safe Yes Yes Yes Materials Probe 316/316L (1.4401/1.4404) Hastelloy C (2.4819) Monel (2.4360) 316/316L (1.4401/1.4404) Hastelloy C (2.4819) Monel (2.4360) 316/316L (1.4401/1.4404) Hastelloy C (2.4819) Monel (2.4360) Process Seal Teflon TFE with Viton o-rings Hermetic Glass Ceramic, Inconel Hermetic Glass Ceramic, Inconel Spacers PEEK PEEK PEEK HT/Celazole Probe Outside Diameter 2" Chamber 3" Chamber 4" Chamber Process Connection Flanged.5" (13 mm) to.75" (19 mm).75" (19 mm) to 1.13" (29 mm) 1.05" (27 mm) to 1.50" (38 mm) Various ANSI, EN1092, and proprietary flanges.5" (13 mm) to.75" (19 mm).75" (19 mm) to 1.13" (29 mm) 1.05" (27 mm) to 1.50" (38 mm) Various ANSI, EN1092, and proprietary flanges.5" (13 mm) to.75" (19 mm).75" (19 mm) to 1.13" (29 mm) 1.05" (27 mm) to 1.50" (38 mm) Various ANSI, EN1092, and proprietary flanges Available Probe Length 12 to 240 inches (30 to 610 cm) 12 to 240 inches (30 to 610 cm) 12 to 240 inches (30 to 610 cm) Transition Zones Top Bottom 0 inches (0 mm) ε r = 1.4: 6 inches (150 mm) ƒ, ε r = 80: 2 inches (50 mm) 0 inches (0 mm) ε r = 1.4: 6 inches (150 mm) ƒ, ε r = 80: 2 inches (50 mm) 0 inches (0 mm) ε r = 1.4: 6 inches (150 mm) ƒ, ε r = 80: 2 inches (50 mm) Process Temperature -40 to +400 F (-40 to +200 C) -320 to +400 F (-196 to +200 C) -320 to +850 F (-196 to +450 C) Max. Process Pressure F ( C) F ( C) F ( C) Dielectric Range 1.4 to to to 100 Vacuum Service Negative Pressure, but no hermetic seal Full Vacuum Full Vacuum Viscosity 10,000cP (mpa.s) 10,000cP (mpa.s) 10,000cP (mpa.s) Media Coating Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Other o-ring materials available upon request. Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. Refer to chart on page 16. ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed to < atmosphere helium. ƒ Can be reduced to 3" (75 mm) when lower accuracy is acceptable. 1.2 minimum dielectric when end of probe analysis is enabled. When installed in the proper chamber/cage/stilling well. Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) 12

13 S I N G L E R O D R I G I D P R O B E M A T R I X 7yF 7yM 7yN Description Standard Temperature High Pressure High Temp./High Pressure Application Level Level Level Installation Tank Tank Tank Overfill Safe No No No Materials Probe 316/316L (1.4401/1.4404) Hastelloy C (2.4819) Monel (2.4360) PFA Insulated 316/316L rod 316/316L (1.4401/1.4404) Hastelloy C (2.4819) Monel (2.4360) 316/316L (1.4401/1.4404) Hastelloy C (2.4819) Monel (2.4360) Process Seal Teflon TFE with Viton o-rings Hermetic Glass Ceramic, Inconel Hermetic Glass Ceramic, Inconel Spacers None None PEEK HT/Celazole Probe Outside Diameter Bare: 0.38" (10 mm) rod Bare: 0.38" (10 mm) rod Bare: 0.50" (13 mm) rod Coated: 0.625" (16 mm) rod Process Connection Threaded Flanged Available Probe Length 1" or 2 (NPT or BSP) Various ANSI, EN1092, and proprietary flanges 24 to 288 inches (60 to 732 cm) 240 inches (610 cm) maximum for PFA coated probes 1" or 2 (NPT or BSP) Various ANSI, EN1092, and proprietary flanges 2 (NPT or BSP) Various ANSI, EN1092, and proprietary flanges 24 to 288 inches (60 to 732 cm) 24 to 288 inches (60 to 732 cm) Transition Zones Top Bottom Application Dependent ε r = 1.4: 6 inches (150 mm) ƒ, ε r = 80: 2 inches (50 mm) Application Dependent ε r = 1.4: 6 inches (150 mm) ƒ, ε r = 80: 2 inches (50 mm) Application Dependent ε r = 1.4: 6 inches (150 mm) ƒ, ε r = 80: 2 inches (50 mm) Process Temperature -40 to +400 F (-40 to +200 C) -320 to +400 F (-196 to +200 C) -320 to +850 F (-196 to +450 C) Max. Process Pressure F ( C) F ( C) F ( C) Dielectric Range 1.7 to to to 100 Vacuum Service Negative Pressure, Full Vacuum Full Vacuum but no hermetic seal Viscosity 10,000cP (mpa.s) 10,000cP (mpa.s) 10,000cP (mpa.s) Media Coating Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Other o-ring materials available upon request. Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. Refer to chart on page 16. ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed to < atmosphere helium. ƒ Can be reduced to 3" (75 mm) when lower accuracy is acceptable. 1.2 minimum dielectric when end of probe analysis is enabled. Overfill capability can be achieved with software. Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) 13

14 F L E X I B L E P R O B E S F O R L I Q U I D S M A T R I X 7y1 7y3 Description Single Flexible Standard Temperature Single Flexible High Pressure Application Level Level Installation Tank Tank Overfill Safe No No Materials Cable 316 (1.4401) (optional PFA coating) 316 (1.4401) Process Seal Teflon TFE with Viton o-rings Hermetic Glass Ceramic Probe Outside Diameter 0.19 inches (5 mm) 0.19 inches (5 mm) Process Connection Threaded Flanged 2" NPT or 2" BSP Various ANSI, EN1092, and proprietary flanges 2" NPT or 2" BSP Various ANSI, EN1092, and proprietary flanges Available Probe Length 3 to 100 feet (1 to 30 meters) 3 to 100 feet (1 to 30 meters) Transition Zones Top Bottom 18 inches (45 cm) 12 inches (30 cm) 18 inches (45 cm) 12 inches (30 cm) Process Temperature -40 to +400 F (-40 to +200 C) -320 to +400 F (-196 to +200 C) Max. Process Pressure F ( C) F ( C) Dielectric Range ƒ 1.7 to to 100 Vacuum Service Negative Pressure, but no hermetic seal Full Vacuum Viscosity 10,000 (mpa.s) 10,000 (mpa.s) Media Coating Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Other o-ring materials available upon request. Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. Refer to chart on page 16. ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed to < atmosphere helium. ƒ 1.2 minimum dielectric when end of probe analysis is enabled. Overfill capability can be achieved with software. 14

15 F L E X I B L E P R O B E S F O R L I Q U I D S M A T R I X C O N T I N U E D 7y4 (Future) 7y6 7y7 Description Single Flexible Standard Temperature Single Flexible HTHP Twin Flexible Standard Temperature Application Level Level Level/Interface Installation Chamber Tank/Chamber Tank/Chamber Overfill Safe No No No Materials Cable 316 (1.4401) 316 (1.4401) 316 SS (1.4401) Cables with FEP Webbing Process Seal Teflon TFE with Viton o-rings Hermetic Glass Ceramic Teflon TFE with Viton o-rings Cable Outside Diameter 0.19 inches (5 mm) 0.19 inches (5 mm) (2) 0.25 inches (6 mm) Process Connection Threaded Flanged 2" NPT or 2" BSP Various ANSI, EN, and proprietary flanges 2" NPT or 2" BSP Various ANSI, EN, and proprietary flanges 2" NPT or 2" BSP Various ANSI, EN, and proprietary flanges Available Probe Length 3 to 100 feet (1 to 30 meters) 3 to 100 feet (1 to 30 meters) 3 to 100 feet (1 to 30 meters) Transition Zones Top Bottom 18 inches (45 cm) 12 inches (30 cm) 18 inches (45 cm) 12 inches (30 cm) 18 inches (45 cm) 12 inches (30 cm) Process Temperature -40 to +400 F (-40 to +200 C) -320 to +850 F (-196 to +450 C) -40 to +400 F (-40 to +200 C) Max. Process Pressure F ( C) F ( C) F ( C) Dielectric Range ƒ 1.7 to to to 100 Vacuum Service Negative Pressure, but no hermetic seal Full Vacuum Negative Pressure, but no hermetic seal Viscosity 10,000 (mpa.s) 10,000 (mpa.s) 1500 (mpa.s) Media Coating Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Other o-ring materials available upon request. Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. Refer to chart on page 16. ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed to < atmosphere helium. ƒ 1.2 minimum dielectric when end of probe analysis is enabled. 15

16 F L E X I B L E P R O B E S F O R S O L I D S M A T R I X 7y2 7y5 Description Single Flexible Standard Temp. Twin Flexible Standard Temp. Application Level Level Installation Tank Tank Overfill Safe No No Pull Down Force 3000 lbs. (1360 Kg) 3000 lbs (1360 Kg) Materials Cable 316 (1.4401) 316 (1.4401) Probe Outside Diameter 0.19 inches (5 mm) (2) 0.25 inches (6 mm) Process Connection Threaded Flanged 2" NPT or 2" BSP Various ANSI, EN1092, and proprietary flanges 2" NPT or 2" BSP Various ANSI, EN1092, and proprietary flanges Available Probe Length 3 to 100 feet (1 to 30 meters) 3 to 100 feet (1 to 30 meters) Transition Zones Top Bottom 18 inches (45 cm) 12 inches (30 cm) 18 inches (45 cm) 12 inches (30 cm) Dielectric Range 4 to to 100 Vacuum Service Negative Pressure, but no hermetic seal Negative Pressure, but no hermetic seal Viscosity 10,000 (mpa.s) 10,000 (mpa.s) Media Coating Max. Error 10% of coated length (% Error is dependent on dielectric & thickness) Max. Error 10% of coated length (% Error is dependent on dielectric & thickness) Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. 1.2 minimum dielectric when end of probe analysis is enabled. ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed (helium leak < atmos.). Maximum Pressure (PSI) yL, 7yM and 7yP Temperature/Pressure Ratings /316L SST 3500 Hastelloy C276 Monel Temperature ( F) Maximum Pressure (PSI) yD, 7yJ, 7yN, 7y3 and 7y6 Temperature/Pressure Ratings Temperature ( F) 316/316L SST Hastelloy C276 Monel 400 High Pressure Probes Low Pressure High Pressure Probes Low Pressure Temp. SST Hastelloy Monel All Materials Temp. SST Hastelloy Monel All Materials NOTES: 7yS steam probes are rated to 2200 psi (155 bar) up to +650 F (+345 C) 7y3, 7y6 flexible probes: Pressure is limited by the chamber 7y2, 7y5 bulk solids probes: 50 psi (3.45 bar) to +150 F (+65 C) High pressure probes with threaded fittings are rated as follows: 7yD, 7yN, 7yP and 7y3 probes with threaded fittings have 3600 psi (248 bar) rating. 7yM probes with threaded fittings have 2016 psi (139 bar) rating. Maximum Pressure (PSI) 7yF, 7yG, 7yT, 7y1, 7y4, 7y Temperature ( F)

17 O - R I N G ( S E A L ) S E L E C T I O N C H A R T O-RING/SEAL SPECIFICATIONS Code O -Ring Material Max. Process Temperature Min. Process Temperature Max. Process Pressure Not Recommended For Applications Recommended for Applications 0 Viton GFLT psi ( bar) -40 F (-40 C) 1000 psi 70 F (70 20 C) Ketones (MEK, acetone), skydrol fluids, amines, anhydrous ammonia, low molecular weight esters and ethers, hot hydrofluoric or chlorosulfuric acids, sour HCs General purpose, ethylene 1 EPDM psi (125 bar) -60 F (-50 C) 1000 psi 70 F (70 20 C) Petroleum oils, di-ester base lubricant, steam Acetone, MEK, skydrol fluids 2 Kalrez psi ( bar) -40 F (-40 C) 1000 psi 70 F (70 20 C) Hot water/steam, hot aliphatic amines, ethylene oxide, propylene oxide Inorganic and organic acids (including hydro fluids and nitric), aldehydes, ethylene, organic oils, glycols, silicone oils, vinegar, sour HCs 3 HSN (Highly Saturated Nitrile) psi ( bar) -4 F (-20 C) 1000 psi 70 F (70 20 C) Halogenated HCs, nitro HCs, phosphate ester hydraulic fluids, ketones (MEK, acetone), strong acids, ozone, automotive brake fluid, steam NACE applications 4 Buna-N psi ( bar) -4 F (-20 C) 1000 psi 70 F (70 20 C) Halogenated HCs, nitro HCs, phosphate ester hydraulic fluids, ketones (MEK, acetone), strong acids, ozone, automotive brake fluid General purpose sealing, petroleum oils and fluids, cold water, silicone greases and oils, di-ester base lubricants, ethylene glycol base fluids 5 Neoprene psi ( bar) -65 F (-55 C) 1000 psi 70 F (70 20 C) Phosphate ester fluids, ketones (MEK, acetone) Refrigerants, high anline point petroleum oils, silicate ester lubricants 6 Chemraz psi ( bar) -20 F (-30 C) 1000 psi 70 F (70 20 C) Acetaldehyde, ammonia + lithium metal solution, butyraldehyde, di-water, freon, ethylene oxide, liquors, isobutyraldehyde Inorganic and organic acids, alkalines, ketones, esters, aldehydes, fuels 7 Polyurethane psi (95 bar) -65 F (-55 C) 1000 psi 70 F (70 20 C) Acids, Ketones, chlorinated HCs, Hydraulic systems, petroleum oils, HC fuel, oxygen, ozone 8 Aegis PF psi ( bar) -4 F (-20 C) 1000 psi 70 F (70 20 C) Black liquor, freon 43, freon 75, galden, KEL-F liquid, molten potassium, molten sodium Inorganic and organic acids (including hydro fluids and nitric), aldehydes, ethylene, organic oils, glycols, silicone oils, vinegar, sour HCs, steam, amines, ethylene oxide, propylene oxide, NACE applications A Kalrez psi ( bar) -40 F (-40 C) 1000 psi 70 F (70 20 C) Hot water/steam, hot aliphatic amines, ethylene oxide, propylene oxide Inorganic and organic acids (including hydro fluids and nitric), aldehydes, ethylene, organic oils, glycols, silicone oils, vinegar, sour HCs B Kalrez psi ( bar) -40 F (-40 C) 1000 psi 70 F (70 20 C) Hot water/steam, hot aliphatic amines, ethylene oxide, propylene oxide Hydrofluoric Acid D or N Glass Ceramic Alloy psi ( bar) -320 F (-195 C) 6250 psi 70 F ( C) Hot alkaline solutions HF acid, media with ph>12, direct exposure to saturated steam General high temperature/high pressure applications, hydrocarbons, full vacuum (hermetic), ammonia, chlorine Maximum +300 F (+150 C) for use on steam. 17

18 R E P L A C E M E N T O F D I S P L A C E R T R A N S M I T T E R S ECLIPSE has proven to be the ideal replacement for existing torque tube transmitters. In numerous applications worldwide, customers have found the performance of ECLIPSE Guided Wave Radar transmitters to be superior to that of antiquated torque tube transmitters. There are several benefits to using the ECLIPSE Model 706 as a replacement for torque tube transmitters: Cost: The cost of a new Model 706 transmitter cost is comparable to rebuilding an aging torque tube. Installation: No field calibration is necessary. The Model 706 transmitter can be configured in minutes with no level movement. (Complete factory pre-configuration is available, which can further decrease the installation effort). Performance: The ECLIPSE Model 706 is unaffected by changes in specific gravity and has no moving parts that can wear and lose tolerance. Ease of replacement: Proprietary and standard ANSI flanges are offered on all ECLIPSE Model 706 probes so existing chamber/cages can be used. In order to match the proper ECLIPSE transmitter with the proper external cage, consider the following: Type of application: Use the proper GWR probe for the application, see pages 7 and 10 through 16. Overfill proof: For optimum performance, use an Overfill-safe probe in all chamber applications. Note: Overfill occurs when the level rises above the maximum range of operation. Some GWR probes may provide erroneous output in this zone unless an optimal, impedancematched design is used. Minimum Cage Size: Coaxial or Caged Coaxial probes: 2" minimum Enlarged Coaxial probes: 3" minimum Twin Cable probes: 4" minimum Before Body connection E 20 ma / 100 % H Displacer Length Measuring range: min 12 (30 cm) max 224" (570) P Probe Insertion Length = E + measuring range + F After 4 ma / 0 % F min 1" (2.5cm) Recommended probe length for replacing displacer transmitters The table below helps to define the GWR probe length for the most common displacer transmitters. Refer to the proprietary flange selection guide. 18 Manufacturer Type Process Connection Displacer Length inches (mm) Probe Length inches (mm) MAGNETROL EZ & PN Modulevel ANSI/EN flange 14" (356) Displacer + 7 (178) Masoneilan Series 1200 Proprietary flange 14" (356) Displacer + 8 (203) ANSI/EN flange 16" (406) Displacer + 8 (203) Fisher series 249B, 259B, 249C cages Proprietary flange 14" (356) Displacer + 10 (254) 2300 & 2500 other cages ANSI flange 14" (356) consult factory Eckardt Series 134, 144 ANSI/EN flange 14" (356) consult factory Tokyo Keiso FST-3000 ANSI/EN flange H = 11.8" (300) Displacer + 9 (229) ANSI/EN flange H = 19.7" (500) Displacer + 9 (229) Round down resulting calculation to the nearest inch.

19 P R O P R I E T A R Y F L A N G E S I N C H E S ( m m ) 9.00 (229) 7.25 (184) 5.62 (143) 4.75 (121) 7.50 (191) (149) (22) 1.25 (32) 0.43 (11) 1.12 (29) 0.87 (22) 1.25 (32) 5.23 (133) 0.22 (6) Fisher 249B/259B (600 lb.), carbon steel 3.37 (86).188 (5) Fisher 249C (600 lb.), 316 stainless steel 4.00 (102) 0.25 (6) Masoneilan (600 lb.), carbon steel M A G N E T R O L C H A M B E R S A brief description of the MAGNETROL chamber offering follows. For more details, refer to MAGNETROL Sales Bulletin MAGNETROL has a long tradition in offering cost-effective chambers. The MAGNETROL external chamber is a self-contained cage designed for use with our top mounting level transmitters or switches. Quality construction and a wide selection of configurations make this cage an ideal means of utilizing the power of Guided Wave Radar without mounting directly into the process vessel. MAGNETROL chambers are available with a wide variety of options, and can be manufactured to comply with various regulations such as: Commercial Design ASME B31.1 Design Code ASME B31.3 Design Code NACE Design Code PED Some Model 706 probes can be installed into chambers as small as 2". When a new chamber is required, it can be ordered together with a factory pre-configured Model 706 for a true plug and play installation. For example: A standard Model A-310 explosion-proof transmitter with a Model 7AG-4300-A Caged probe can be used in a 2" chamber. A typical chamber Model Number would be: F21-4A2D-014 Refer to MAGNETROL Sales Bulletin for details on chamber Model Numbers and additional options. Measuring Range Measuring Range Measuring Range 1" NPT drain 1" NPT drain Sealed Chamber Slip-on head flange Weld neck head flange 19

20 A G E N C Y A P P R O V A L S These units are in compliance with the EMC-directive 2014/30/EU, the PED-directive 2014/68/EU and the ATEX directive 2014/34/EU. Explosion Proof (with intrinsically Safe Probe) US/Canada: Class I, Div 1, Group B, C and D, T4 Class I, Zone 1 AEx d/ia [ia IIC Ga] IIB + H2 T4 Gb/Ga Class I, Zone 1 Ex d/ia [ia IIC Ga] IIB + H2 T4 Gb/Ga Ta = -40ºC to +70ºC Type 4X, IP67 Flame Proof ATEX FM14ATEX0041X: II 2/1 G Ex d/ia [ia IIC Ga] IIB + H2 T6 to T1 Gb/Ga Ta = -40ºC to +70ºC IP67 IEC- IECEx FMG X: Ex d/ia [ia IIC Ga] IIB + H2 T6 to T1 Gb/Ga Ta = -40ºC to +70ºC IP66/67 Non- Incendive US/Canada: Class I, II, III, Division 2, Group A, B, C, D, E, F, G, T4 Class I, Zone 2 AEx ia/na [ia Ga] IIC T4 Ga/Gc Class I, Zone 2 Ex ia/na [ia Ga] IIC T4 Ga/Gc Ta = -40ºC to +70ºC Type 4X, IP67 ATEX FM14ATEX0042X: II 1/3 G Ex ia/na [ia Ga] IIC T4 Ga/Gc Ta = -15ºC to +70ºC IP67 IEC IECEx FMG X: Ex ia/na [ia Ga] IIC T4 Ga/Gc Ta = -15ºC to + 70ºC IP66/67 Intrinsically Safe US/Canada: Class I, II, III, Div 1, Group A, B, C, D, E, F, G, T4, Class I, Zone 0 AEx ia IIC T4 Ga Class I, Zone 0 Ex ia IIC T4 Ga Ta =-40ºC to + 70ºC Type 4X, IP67 ATEX FM14ATEX0041X: II 1 G Ex ia IIC T4 Ga Ta = -40ºC to +70ºC IP67 IEC IECEx FMG X: Ex ia IIC T4 Ga Ta = -40ºC to +70ºC IP66/67 Dust Ignition Proof US/Canada: Class II, III, Division 1, Group E, F and G, T4 Ta = -40ºC to +70ºC Type 4X, IP67 ATEX FM14ATEX0041X: II 1/2 D Ex ia/tb [ia Da] IIIC T85ºC to T450ºC Da/Db Ta = -15ºC to +70ºC IP67 IEC IECEx FMG X: Ex ia tb [ia Da] IIIC T75ºC to T435ºC Db Ex ia IIIC T75ºC to T435ºC Da Ta = -15ºC to +70ºC IP66/67 The following approval standards are applicable: FM3600:2011, FM3610:2010, FM3611:2004, FM3615:2006, FM3616:2011, FM3810:2005, ANSI/ISA :2013, ANSI/ISA :2009, ANSI/ISA :2013, ANSI/ISA :2012, ANSI/ISA :2011, NEMA 250:2003, ANSI/IEC 60529:2004, C22.2 No. 0.4:2009, C22.2 No. 0.5:2008, C22.2 No. 30:2007, C22.2 No. 94:2001, C22.2 No. 157:2012, C22.2 No. 213:2012, C22.2 No :2009, CAN/CSA :2011, CAN/CSA :2011, CAN/CSA :2011, CAN/CSA :2012, C22.2 No :2005, EN :2012, EN :2007, EN :2012, EN :2010, EN :2007, EN :2009, EN60529+A1: , IEC :2011, IEC :2007, IEC :2011, IEC :2010, IEC :2006, IEC :

Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter

Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter D E S C R I P T I O N The new Eclipse Model 706 High Performance Transmitter is a loop-powered, 24 VDC level transmitter that is based

More information

Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter

Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter DESCRIPTION The Eclipse Model 706 High Performance Transmitter is a loop-powered, 24 VDC level transmitter that is based upon the

More information

Horizon Model 704 Guided Wave Radar Level Transmitter

Horizon Model 704 Guided Wave Radar Level Transmitter Horizon Model 704 Guided Wave Radar Level Transmitter D E S C R I P T I O N The Horizon Model 704 Transmitter is an intermediately priced 24 VDC, loop-powered, liquid level transmitter based upon Guided

More information

Advanced Guided Wave Radar Transmitter for Level Measurement and Control

Advanced Guided Wave Radar Transmitter for Level Measurement and Control Advanced Guided Wave Radar Transmitter for Level Measurement and Control ECLIPSE Guided Wave Radar Magnetrol pioneered guided wave radar (GWR) by introducing the ECLIPSE Model 705 two-wire, loop-powered

More information

Guided Wave Radar Bulk Solids Level Transmitter

Guided Wave Radar Bulk Solids Level Transmitter www.ktekcorp.com Guided Wave Radar Bulk Solids Level Transmitter FEATURES Radar Signal Travels Along the Waveguide Eliminates False Echoes and Minimizes Signal Loss No Moving Parts 2 Wire Loop Powered

More information

Pulsar Model R86 26 GHz Pulse Burst Radar Level Transmitter

Pulsar Model R86 26 GHz Pulse Burst Radar Level Transmitter Pulsar Model R86 26 GHz Pulse Burst Radar Level Transmitter D E S C R I P T I O N The Pulsar Model R86 radar transmitter is the latest generation of Magnetrol 24 VDC, loop-powered, noncontact radar transmitters.

More information

Pulsar Model R96 Pulse Burst Radar Level Transmitter

Pulsar Model R96 Pulse Burst Radar Level Transmitter Pulsar Model R96 Pulse Burst Radar Level Transmitter D E S C R I P T I O N The Pulsar R96 Radar transmitter is the latest generation of Magnetrol 24 VDC, loop-powered, noncontact radar transmitters. Enhanced

More information

Guided Wave Radar Level Transmitter

Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter 705 D E S C R I P T I O N The Eclipse 705 Transmitter is a loop-powered, 24 V DC liquid-level transmitter based on the revolutionary Guided Wave Radar (GWR) technology.

More information

Guided Wave Radar Level and Interface Transmitter

Guided Wave Radar Level and Interface Transmitter www.ktekcorp.com Guided Wave Radar Level and Interface Transmitter FEATURES Total and Interface Level Measurement with One Transmitter Graphic Display with Waveform Screen All Digital Electronics Weak

More information

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter D E S C R I P T I O N The Enhanced Eclipse Model 705 is a loop-powered, 24 VDC, level transmitter based upon the revolutionary Guided Wave

More information

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter D E S C R I P T I O N The Enhanced Eclipse Model 705 Transmitter is a looppowered, 24 VDC liquid-level transmitter based on the revolutionary

More information

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter D E S C R I P T I O N The Enhanced Eclipse Model 705 Transmitter is a looppowered, 24 VDC liquid-level transmitter based on the revolutionary

More information

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter D E S C R I P T I O N The Enhanced Eclipse Model 705 is a loop-powered, 24 VDC, level transmitter based upon the revolutionary Guided Wave

More information

H O R I Z O N G U I D E D W A V E R A D A R

H O R I Z O N G U I D E D W A V E R A D A R H O R I Z O N G U I D E D W A V E R A D A R An Introduction To Horizon Guided Wave Radar H orizon transmitters utilize Guided Wave Radar (GWR) technology for unsurpassed accuracy and reliability in monitoring

More information

Guided Wave Radar Level Transmitter

Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter www.eclipse.magnetrol.com 705 D E S C R I P T I O N The Eclipse 705 Transmitter is a loop-powered, 24 V DC liquid-level transmitter based on the revolutionary Guided

More information

Guided Wave Radar Liquid-Liquid Interface Transmitter

Guided Wave Radar Liquid-Liquid Interface Transmitter Guided Wave Radar Liquid-Liquid Interface Transmitter TM 707 DESCRIPTION The Eclipse 707 Transmitter is a loop-powered, 24 V DC liquid-level transmitter based on the revolutionary Guided Wave Radar (GWR)

More information

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement

More information

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) and Volumetric for Total Level Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement

More information

Your needs are always on our Radar

Your needs are always on our Radar Your needs are always on our Radar MAGNETROL is recognized as the global leader in level and flow solutions. But in many process control industries, the name MAGNETROL has become another word for radar

More information

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET t DREXELBROOK DATA SHEET DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy

More information

E C L I P S E G U I D E D W A V E R A D A R

E C L I P S E G U I D E D W A V E R A D A R E C L I P S E G U I D E D W A V E R A D A R The Total Spectrum of Solutions Magnetrol s products employ a number of technologies to meet the challenges of level and flow control. Eclipse transmitters utilize

More information

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S ECHOTEL 961/962 Ultrasonic level switches D E S C R I P T I O N The Echotel 961/962 series utilizes pulse signal technology to detect high or low level alarm(s) in a broad range of viscous to light liquids.

More information

Guided Wave Radar Level and Interface Transmitter

Guided Wave Radar Level and Interface Transmitter Product Data Sheet Online Only The Rosemount 3300 Series consists of smart, loop-powered level and interface transmitters based on guided wave radar technology. These instruments provide outstanding reliable

More information

ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch

ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch ECHOTEL 915 series 2 Wire, current shift Ultrasonic level switch DESCRIPTION Echotel 915 series ultrasonic level controls are 2 wire (24 V DC) integral units which utilize pulsed wave technology to detect

More information

K-COM Communications Software Loop Indicator

K-COM Communications Software Loop Indicator FEATURES Graphic Display with Waveform Screens All Digital Electronics Radar Signal Travels Along the Waveguide Eliminates False Echoes and Minimizes Signal Loss No Moving Parts 2 Wire Loop Powered Linearization

More information

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter Magnetostrictive Transmitters D E S C R I P T I O N The Enhanced Jupiter Magnetostrictive level transmitter provides a 4 20 ma output proportional to the level being measured or FOUNDATION fieldbus output.

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

HORIZON 704. Guided Wave Radar Level Transmitter. Worldwide level and flow solutions

HORIZON 704. Guided Wave Radar Level Transmitter. Worldwide level and flow solutions HORIZON 704 Guided Wave Radar Level Transmitter DESCRIPTION The Horizon 704 is a loop-powered, 24 V DC liquid-level transmitter based on the revolutionary Guided Wave Radar (GWR) technology. The electronics

More information

Technologies, Solutions, and Applications. Guided Wave Radar for Level

Technologies, Solutions, and Applications. Guided Wave Radar for Level Technologies, Solutions, and Applications Guided Wave Radar for Level Contents Leadership in Guided Wave Radar 3 Principles of Operation 4 Models and Versions 5 Guided Wave Radar in the plics System 8

More information

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter.   LEVEL. Technology Solutions Technology Solutions TEK-F LEX 4100A Guided Wave Radar Level Transmitter LEVEL www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Featuring TDR (Time Domain

More information

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications D E S C R I P T I O N The Enhanced Eclipse Model 705 is a loop-powered, 24 VDC, level transmitter based upon the revolutionary

More information

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications D E S C R I P T I O N The Enhanced Eclipse Model 705 is a loop-powered, 24 VDC, level transmitter based upon the revolutionary

More information

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below BLISSFLEX 1100 The characters of the order code have been described below BA25 4 BLISSFLEX 1100 C 2-wire loop-powered 4...20 ma Guided Radar (TDR) level meter: -50...+100 C and -1...16 barg / -58...212

More information

Rosemount 3300 Series Guided Wave Radar Level and Interface Transmitter

Rosemount 3300 Series Guided Wave Radar Level and Interface Transmitter Product Data Sheet Guided Wave Radar Level and Interface Transmitter comprises smart, loop-powered level and interface transmitters based on the guided wave radar technology. These instruments provide

More information

Technologies, Solutions, and Applications. Magnetic Level Indication and Bridle Measurements

Technologies, Solutions, and Applications. Magnetic Level Indication and Bridle Measurements Technologies, Solutions, and Applications Magnetic Level Indication and Bridle Measurements Contents Leadership in Magnetic Level Indicators and Bridles 3 How We Earn Your Business 4 Magnetic Level Indictor

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:

More information

Rosemount 3101, 3102, and 3105

Rosemount 3101, 3102, and 3105 Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as

More information

LEVEL Transmitters. SAP-300 display. Mono cable / Mono rod Mono segmented rod. Twin cable Twin rod Coaxial Pipe

LEVEL Transmitters. SAP-300 display. Mono cable / Mono rod Mono segmented rod. Twin cable Twin rod Coaxial Pipe Guided microwave level transmitters GENERAL DESCRITION The Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids, pulps and solids. level

More information

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology RefineME 4-IN-1 Measurement Inherent Accuracy ±1 mm API Temperature Corrected Volumes No Scheduled Maintenance or Recalibration

More information

FOSTEN AUTOMATION SÉRIE F500-RD

FOSTEN AUTOMATION SÉRIE F500-RD FOSTEN AUTOMATION SÉRIE Guided Wave Radar Level Transmitter Guided wave radar level transmitter. Low maintenance, auto calibrated references. Easy installation, directly in tanks or auxiliary vessels.

More information

PRODUCT LINE CATALOGUE

PRODUCT LINE CATALOGUE PRODUCT LINE CATALOGUE Worldwide Level and Flow Solutions SM VISION STATEMENT To be the customers preferred partner in the global supply of level and flow control solutions 2 COMPANY COMPANY Industry leader

More information

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level measurement independent of changing process conditions (density, conductivity, temperature, pressure, ) Innovative

More information

TGF2200 Micro Pulse Level Meter

TGF2200 Micro Pulse Level Meter Guided Radar with 2-wire system TGF2200 Micro Pulse Level Meter OUTLINE The TGF2200 series is a unique 2-wire continuous level-measuring instrument using TDR technology. The simple and compact design suitable

More information

High Performance, 4th Generation Guided Wave Radar Level Transmitter

High Performance, 4th Generation Guided Wave Radar Level Transmitter Hart Installation and Operating Manual for Eclipse Model 706 Software Version 1.x High Performance, 4th Generation Guided Wave Radar Level Transmitter Read this Manual Before Installing This manual provides

More information

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products Data sheet DS/-EN Rev. T Magnetostrictive Level Transmitter External mounted magnetostrictive level transmitter K-TEK Products Features SIL2 Certified IEC 61508* Designed to mount externally to K-TEK KM26

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Overview Söm-Tek TM The SKMT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass

More information

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output. Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision K FEATURES 4 to 20

More information

OEM radar transmitter, for aggressive media level measurement

OEM radar transmitter, for aggressive media level measurement OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type

More information

THE NEXT GENERATION IN MAGNETIC LEVEL INDICATION

THE NEXT GENERATION IN MAGNETIC LEVEL INDICATION FEATURING: THE NEXT GENERATION IN MAGNETIC LEVEL INDICATION 2. Aurora MLI: Operating Principles True Redundancy in a Single Chamber The Aurora Magnetic Level Indicator (MLI) combines Eclipse Guided Wave

More information

JUPITER 200. Magnetostrictive Level Transmitter. Worldwide level and flow solutions. Measures «LEVEL» and «INTERFACE» D E S C R I P T I O N

JUPITER 200. Magnetostrictive Level Transmitter. Worldwide level and flow solutions. Measures «LEVEL» and «INTERFACE» D E S C R I P T I O N JUPITER 200 Magnetostrictive Level Transmitter D E S C R I P T I O N The Jupiter 200 transmitter is a loop-powered, 24 V DC liquid-level transmitter and utilises the effect of a magnetic field on the magnetostrictive

More information

High Performance Guided Wave Radar

High Performance Guided Wave Radar High Performance Guided Wave Radar The is our premium 2-wire guided wave radar for challenging level and interface measurements on liquids, slurries and solids. It delivers everything you would expect

More information

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS 3 YEARS WARRANTY PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS MAIN FEATURES 2-wire K-band Pulse Burst Radar 25 GHz frequency

More information

SITRANS LR 300: High Performance Radar for Level Measurement

SITRANS LR 300: High Performance Radar for Level Measurement SITRANS LR 300: High Performance Radar for Level Measurement Reliable Measurement In Extreme Conditions SITRANS LR 300 delivers high performance level measurement at an affordable price for the chemical,

More information

SMARTLINE LEVEL SLG700

SMARTLINE LEVEL SLG700 Tom Brans Date SMARTLINE LEVEL SLG700 Guided Wave Radar Update Honeywell ENRAF legacy 1 1 Insert Text Here - Secondary Bullet Tertiary Bullet Over 60 years of tradition Winning Terminal Inventory Solutions

More information

Guided Wave Radar TODAY S VANGUARD IN LEVEL MEASUREMENT

Guided Wave Radar TODAY S VANGUARD IN LEVEL MEASUREMENT Guided Wave Radar TODAY S VANGUARD IN LEVEL MEASUREMENT Today s Vanguard in Level Measurement Guided Wave Radar (GWR), the increasingly popular, industrial, loop-powered transmitter we know today, burst

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

Echotel Trident 91S/92S Ultrasonic Level Switches

Echotel Trident 91S/92S Ultrasonic Level Switches Echotel Trident 91S/92S Ultrasonic Level Switches D E S C R I P T I O N The Trident 91S/92S detects single or dual point level in a wide variety of liquid applications. It is available with either an ma

More information

Technical Datasheet. Guided Radar (TDR) Level Transmitter for heavy-duty and interface applications

Technical Datasheet. Guided Radar (TDR) Level Transmitter for heavy-duty and interface applications OPTIFLEX 1300 C Technical Datasheet Guided Radar (TDR) Level Transmitter for heavy-duty and interface applications Universal device that can measure level of liquids, pastes, granulates, powders, and liquid

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature

More information

Level Measurement With REFLEX RADAR

Level Measurement With REFLEX RADAR Reflex Radar & TDR HYC-RR03 Elect. Iss. 03 Level Measurement With REFLEX RADAR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam

More information

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging. ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging. Technical Specifications Data Communication Honeywell Bi-phase mark (Pos 2 = E and I) 1200 / 2400 bps > 1,500 V Full galvanic separation via isolating

More information

FOR LIQUIDS AND SOLIDS

FOR LIQUIDS AND SOLIDS FOR LIQUIDS AND SOLIDS LEVEL TRANSMITTERS GUIDED MICROWAVE LEVEL TRANSMITTERS O U R P R O F E S S I O N MicroTREK LEVEL TRANSMITTERS FOR LIQUIDS AND SOLIDS MAIN FEATURES Measuring range up to 24 m (80

More information

TGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE

TGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE 2-wire System Guided Radar Gauge TGR3000 MICRO-PULSE level meter GENERAL TGR3000 series is the 2-wire system Guided Radar Gauge which can continuously measure the level using micro-pulse. The micropulse

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter The Model KMD is an advanced, state-of-the-art, two-wire, Magnetostrictive-based level transmitter suitable for a wide range of process applications. The latest in microprocessor

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Level Plus. SoCLEAN Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Level Plus. SoCLEAN Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology SoCLEAN Sanitary and Electropolished Finish Inherent Accuracy ±1 mm No Scheduled Maintenance or Recalibration Hazardous

More information

Superior Performance Two-Wire Non-Contacting Radar Level Transmitter

Superior Performance Two-Wire Non-Contacting Radar Level Transmitter Accurate and reliable, direct level measurement, virtually unaffected by process conditions Best performance and uptime provided by dual port technology, advanced surface tracking capability, and condensation-

More information

GUIDED WAVE RADAR TRANSMITTER

GUIDED WAVE RADAR TRANSMITTER GUIDED WAVE RADAR TRANSMITTER FOR CONTINUOUS LEVEL MEASUREMENT Based on Time Domain Reflectometry (TRD) principle Not affected by density and/or temperature variations Not affected by viscosity, gravity,

More information

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration Siemens G 200 Overview onfiguration Installation uild up of material in active shield area does not affect switch operation. Mounting on a bypass is an inverse frequency shift capacitance continuous level

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high

More information

Technologies, Solutions and Applications. Magnetic Level Indication and Bridle Measurements

Technologies, Solutions and Applications. Magnetic Level Indication and Bridle Measurements Technologies, Solutions and Applications Magnetic Level Indication and Bridle Measurements Magnetic Level Indicators and Bridles VEGA is dedicated to offering complete magnetic level indication and engineered

More information

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical

More information

Smart Displacer Level (Interface) Transmitter DLT100 Series

Smart Displacer Level (Interface) Transmitter DLT100 Series Smart Displacer Level (Interface) Transmitter DLT100 Series Equipped with FISHER FIELDVUE DLC3010 1 Introduction DLT100 series is Smart Displacer Level (Interface) Transmitter equipped with the original

More information

Radar Level Measurement micropilot FMR 130 for stilling wells

Radar Level Measurement micropilot FMR 130 for stilling wells Technical Information TI 258F/24/ae Radar Level Measurement micropilot FMR 130 for stilling wells Smart transmitter for non-contact measurement in metallic by-pass pipes and stilling wells Suitable for

More information

Accutech DP20. Wireless differential pressure field unit

Accutech DP20. Wireless differential pressure field unit Accutech DP20 Wireless differential pressure field unit 1 The Accutech DP20 differential pressure field unit provides differential pressure data in a variety of ranges up to +/-300in H 2 0. Both traditional

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

REFLEX RADAR INDICATOR

REFLEX RADAR INDICATOR REFLEX RADAR INDICATOR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam Temperature THE ADVANTAGES ARE Measuring ranges up to

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Data Sheet

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Data Sheet Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology Tank SLAYER 3-IN-1 Measurement Inherent Accuracy ±1 mm API Temperature Corrected Volumes No Scheduled Maintenance or Recalibration

More information

AT200 External Mount Magnetostrictive Level Transmitter

AT200 External Mount Magnetostrictive Level Transmitter Data sheet DS/AT200-EN Rev. W AT200 External Mount Magnetostrictive Level Transmitter High accuracy liquid level and interface level detection K-TEK Level Products Measurement made easy Features Certified

More information

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in: oxy.iq Panametrics Oxygen Transmitter Applications An oxygen transmitter for use in: Glove box purge and leak detection Natural gas Semiconductor wafer machines Coating process machines Membrane air separators

More information

E3 Modulevel. Displacer operated level transmitter A G E N C Y A P P R O VA L S. For continuous level, density or liquid-liquid interface

E3 Modulevel. Displacer operated level transmitter A G E N C Y A P P R O VA L S. For continuous level, density or liquid-liquid interface E3 Modulevel Displacer operated level transmitter D E S C R I P T I O N E3 Modulevels are 2 wire, loop powered level transmitters utilising buoyancy principle to detect and convert liquid level changes

More information

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

Rosemount 5300 Series

Rosemount 5300 Series Rosemount 5300 Series High Performance Guided Wave Radar Designed To Make The Difference Innovative Design. Real Results. The Rosemount 5300 Series is the next generation of Guided Wave Radar (GWR) from

More information

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES 6GHz Intelligent Radar Level Meter Product Manual Model:KRD520 SERIES Directory 1 Product Overview...1 2 Product Introduction...2 3 The Installation Requirements...4 4 The Electrical Connection...6 5 Instrument

More information

General Specifications

General Specifications General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

General Specifications

General Specifications General Specifications GS 01F06F01-01EN Model DY Vortex Flowmeter Model DYA Vortex Flow Converter FOUNDATION Fieldbus Communication Type General FOUNDATION Fieldbus is the digital communication line for

More information

OPTIWAVE 1010 Technical Datasheet

OPTIWAVE 1010 Technical Datasheet OPTIWAVE 1010 Technical Datasheet Radar (FMCW) Level Transmitter for bypass chambers and magnetic level indicators (BM 26 Advanced) Device welded to a bypass chamber with an optional IP68 level indicator

More information

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement Technical Data Sheet Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin measurement device that detects irregular surfaces in powder or solid materials and

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers

Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers 84-3-424, Rev BA May 29 Rosemount Radar Transmitters Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers INTRODUCTION This document provides a guideline for choosing and

More information

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products Data sheet DS/AT100S-EN Rev. N AT100S Magnetostrictive Level Transmitter Sanitary magnetostrictive level transmitter K-TEK Products Features SIL2 Certified IEC 61508* High Accuracy:.01% of Full Scale Superior

More information

Micro Motion Fork Density Meters

Micro Motion Fork Density Meters Micro Motion Fork Density Meters Direct insertion density meter Product Data Sheet PS-001485, Rev F November 2018 Rugged, accurate density and concentration measurement Continuous, real-time measurement

More information

MicroTREK GUIDED MICROWAVE LEVEL TRANSMITTERS

MicroTREK GUIDED MICROWAVE LEVEL TRANSMITTERS For liquids and solids MicroTREK GUIDED MICROWAVE LEVEL TRANSMITTERS O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL TRANSMITTERS MicroTREK TRANSMITTERS FOR LIQUIDS AND SOLIDS FEATURES Measuring

More information

Rosemount 3300 Series Guided Wave Radar Level & Interface Transmitter

Rosemount 3300 Series Guided Wave Radar Level & Interface Transmitter Rosemount 3300 Series Guided Wave Radar Level & Interface Transmitter Reliable and effortless measurement in demanding applications High reliability increases uptime Efficient digital sampling, advanced

More information