IQxel-M TM Multi-DUT/Multicom Connectivity Test System

Size: px
Start display at page:

Download "IQxel-M TM Multi-DUT/Multicom Connectivity Test System"

Transcription

1 TECHNICAL SPECIFICATIONS IQxel-M TM Multi-DUT/Multicom Connectivity Test System 2017 LitePoint, A Teradyne Company. All rights reserved.

2 Overview of IQxel-M The IQxel-M is a manufacturing oriented, Multi-DUT, Multicom test system, designed to calibrate and verify performance of wireless connectivity devices in high-volume production environments. The IQxel-M makes use of non-signaling physical layer test methods to significantly increase test throughput when compared to signaling based methodologies typical of R&D and conformance testing. Enabled by LitePoint s fifth generation Packet Engine processor, the IQxel-M is capable of performing simultaneous testing on up to four devices using synchronous and/or asynchronous parallel test methods. This maximizes test efficiency and minimizes the total cost of test of wireless connectivity products. Highest Test Throughput for Multicom Wireless Connectivity Devices The IQxel-M supports multiple connectivity technologies with banded frequency coverage from 60 MHz to 6,000 MHz. It provides full Tx/Rx physical layer testing of a/b/g/n/j/p/ac, ah, Bluetooth , ZigBee, Z-Wave, WiSUN, LTE-U and DECT. It also provides receiver testing of GPS, GLONASS, COMPASS, Galileo, and FM. IQxel-M addresses the ever-increasing capabilities of smart connected devices with the ability to simultaneously test Wi-Fi/BT functionality on up to four (4) devices while concurrently performing navigation and broadcast tests further increases the throughput capabilities of the system. Multi-DUT/Multicom Connectivity Test System 2

3 General Technical Specifications RF Analyzer Parameter Ports Value Input frequency range 860 to 1000 MHz 1770 to 2660 MHz 3300 to 3800 MHz 4900 to 6000 MHz IF bandwidth 120 MHz Input power range +30 dbm peak (+25 dbm average) Input power accuracy 1 Specification: Typical: ± 0.75 db (+20 to -75 dbm) ± 0.50 db (+20 to -75 dbm) Quantization 16 bits Input return loss 1000 MHz, >10 db >1000 MHz, >12 db In band spurious < -55 dbc (50 khz RBW) (CW, +20 to -40 dbm) Spectral flatness Specification: Typical: ± 0.50 db (± 40 MHz) ± 0.25 db (± 40 MHz) Inherent spurious floor -80 dbm Noise figure Integrated phase noise Signal to noise ratio Sampling data rate 30 db at minimum input attenuation 0.3 degrees (100 Hz to 1 MHz) (860 to 1000 MHz) 0.3 degrees (100 Hz to 1 MHz) (1770 to 2660 MHz) 0.4 degrees (100 Hz to 1 MHz) (3300 to 3800 MHz) 0.4 degrees (100 Hz to 1 MHz) (4900 to 6000 MHz) 0.2 degrees (100 Hz to 1 MHz) typical, for all frequencies 55 db 100 khz RBW 10, 20, 40, 80, 160 MHz at 10 MHz sampling data rate at 20 MHz sampling data rate 3200 ms 1600 ms Waveform capture duration at 40 MHz sampling data rate 800 ms at 80 MHz sampling data rate 400 ms at 160 MHz sampling data rate 200 ms 1 Input power accuracy specification applies after a warm up period of 2 hours or more Multi-DUT/Multicom Connectivity Test System 3

4 RF Analyzer Signal Trigger Parameter Absolute minimum value Absolute maximum value Trigger relative threshold Level accuracy Range Wideband RF Video Limited by the maximum input power 30 db < +/- 1 db -30 dbm -40 dbm RF Generator Parameter Ports Range Output frequency range 860 to 1000 MHz 1770 to 2660 MHz 3300 to 3800 MHz 4900 to 6000 MHz IF bandwidth 120 MHz Output power range (CW) 1 port active: +10 to -95 dbm ( 2600 MHz) 0 to -95 dbm (> 2600 MHz) All ports active: +5 to -95 dbm ( 2600 MHz) -5 to -95 dbm (> 2600 MHz) Output power accuracy 1 Specification: ± 0.75 db ( 0 to -95 dbm) Typical: ± 0.50 db ( 0 to -95 dbm) Quantization 16 bits Output return loss 1000 MHz, >10 db >1000 MHz, >12 db Spurious (in channel) Specification: Typical: -40 dbc or -95 dbm (80 MHz) (CW) -50 dbc or -95 dbm (80 MHz) (CW) Spurious (out of channel) Out-of-band (>± 40 MHz from carrier): -45 dbc (CW, excluding harmonics distortions) Spectral flatness Specification: Typical: ± 0.50 db (± 40 MHz) ± 0.25 db (± 40 MHz) Integrated phase noise 0.3 degrees (100 Hz to 1 MHz) (860 to 1000 MHz) 0.3 degrees (100 Hz to 1 MHz) (1770 to 2660 MHz) 0.4 degrees (100 Hz to 1 MHz) (3300 to 3800 MHz) 0.4 degrees (100 Hz to 1 MHz) (4900 to 6000 MHz) 0.2 degrees (100 Hz to 1 MHz) typical 1 Output power accuracy specification applies after a warm up period of 2 hours or more Multi-DUT/Multicom Connectivity Test System 4

5 Signal to noise ratio Specification: Typical: 60 db (100 khz RBW), power level = -45 dbm 70 db (100 khz RBW), power level = -45 dbm Carrier leakage Gap power Sampling data rate -45 dbc (CW output) -90 dbm (between packets, when enhanced gap rejection enabled) -90 dbm/100 khz 10, 20, 40, 80, 160 MHz at 10 MHz sampling data rate 3200 ms Waveform playback duration (non-repeat) at 20 MHz sampling data rate 1600 ms at 40 MHz sampling data rate 800 ms at 80 MHz sampling data rate 400 ms at 160 MHz sampling data rate 200 ms Port Isolation VSA to VSG isolation 2.7 GHz, 100 db typical > 2.7 GHz, 90 db typical Timebase Oscillator type Frequency Initial accuracy (25 o C, after 60 minute warm-up) Maximum aging Temperature stability Warm-up time (to within +/-0.1 ppm at 25 o C) OCXO 10 MHz < +/ ppm < +/- 0.1 ppm per year < +/-0.05 ppm over 0 o C to 50 o C range, referenced to 25 o C < 30 minutes Multi-DUT/Multicom Connectivity Test System 5

6 Navigation Signal Generator (VSG2) Parameter Output frequency range Maximum Doppler offset Output power range Power resolution Level accuracy Output return loss Spurious Range GPS: MHz GLONASS: 1598 to 1606 MHz COMPASS: (+/ ) MHz Galileo: 1559 to 1593 MHz ±10 khz -60 to -145 dbm 0.1dB ±0.7dB (-60 to -100 dbm) ±1dB (-100 to -145 dbm) >15 db Harmonic: < -40 dbc Non-Harmonic: < -40 dbc (+/- 10 MHz) Low Frequency Communication (LFC) Signal Generator Parameter Output frequency range Output power range Frequency resolution Power resolution Level accuracy Output return loss Spurious Range 65 to 240 MHz 470 to 900 MHz +6 to -110 dbm 10 Hz 0.1 db ± 1.0 db >15 db Harmonic: <-65 dbc (in band), <-40dBc (out of band) Non harmonic: <-60 dbc (in band), <-40dBc (out of band) Multi-DUT/Multicom Connectivity Test System 6

7 Wireless LAN ( a/b/g/n/j/p/ac) Measurement Specifications Measurement Description Performance Residual VSA EVM (full packet channel estimation): -45 db (+20 to -20 dbm) -43 db (-20 to -25 dbm) -38 db (-25 to -30 dbm) Residual VSG EVM: -45 db (-5 to -45 dbm) EVM Peak power RMS power Max avg power I/Q amplitude error I/Q phase error Frequency error EVM averaged over payload based on standard requirements Peak power over all symbols (dbm) All: average power of complete data capture (dbm) No gap: average power over all symbols after removal of any gap between packets (dbm) Peak value of the amplitude as a moving average over 40 samples (dbm) I/Q amplitude imbalance (%) and approximate contribution to EVM (db) I/Q phase imbalance (degrees) and approximate contribution to EVM (db) Carrier frequency error (khz) Residual VSA EVM (preamble only channel estimation): -42 db (+20 to -20 dbm) -40 db (-20 to -25 dbm) -35 db (-25 to -30 dbm) Residual VSG EVM: -42 db (-5 to -45 dbm) Note: - Averaged over 20 packets, 16 data OFDM symbols long ac waveform, 80 MHz, MSC 9 (256QAM 5/6) - Measured in system loopback VSA power accuracy: ± 0.75 db (+20 to -35 dbm) Residual VSA I/Q imbalance: 1% (+20 to -35 dbm) Residual VSG I/Q imbalance: 1% (-5 to -70 dbm) Residual VSA I/Q imbalance: 0.5 degree (+20 to -35 dbm) Residual VSG I/Q imbalance: 0.5 degree (-5 to -70 dbm) (For n packet at 16 symbols, EVM better than -25 db) VSA measurement error: ± 0.2 ppm calibrated Multi-DUT/Multicom Connectivity Test System 7

8 Measurement Description Performance RMS phase noise PSD Spectral mask Spectral flatness Sidelobe analysis (spectral mask, LO leakage) CCDF (complementary cumulative distribution function) Power on / power down ramp Integrated phase noise (degrees) Power spectral density (dbm/hz) versus frequency offset center frequency ± 40 MHz Transmit spectrum mask Reflects variation of signal energy as a function of OFDM subcarrier number a/g/p/n/j/ac OFDM signals only Center peak and peaks of 1st and 2nd upper/lower sidelobes (db) b/g DSSS signals only Probability of peak signal power being greater than a given power level versus peak-to-average power ratio (db) On: relative power level (% of average) versus time (802.11b/g CCK signals only) Power-on time from 10% to 90% Power-on time from 90% power level to start of packet (Not provided for a/g/p/n/j/ac OFDM signals) VSA integrated phase noise: < 0.5 degrees (100 Hz to 1 MHz) Spectral mask view: ± 60 MHz VSA flatness over 80 MHz Ch BW: ± 0.5 db Eye diagram PSDU data Raw capture data General waveform analysis CW frequency analysis Off: relative power level (% of average) versus time (802.11b/g CCK signals only) Power-off time from 90% to 10% Power-off time from 90% power level to end of packet (Not provided for a/g/p/n/j/ac OFDM signals) I and Q channels versus time (802.11b/g DSSS signals only) Recovered binary data sequence, including the MAC header and Frame Check Sequence, if present I and Q signals versus time DC offset, RMS level, minimum/maximum amplitude, peak-to-peak amplitude, RMS I- and Q-channel levels Frequency of CW tone Multi-DUT/Multicom Connectivity Test System 8

9 Bluetooth (1.0, 2.0, 2.1, 3.0) Measurement Specifications Measurement Description Performance TX output power Transmit DUT output power (dbm) VSA power accuracy: ± 0.75 db (+20 to -35 dbm) TX output spectrum Transmit DUT power spectral density ± 0.50 db (+20 to -35 dbm) typical 20 db bandwidth In-band emissions (Adjacent channel) Modulation characteristics Carrier frequency tolerance Carrier frequency drift Relative transmit power (EDR) Carrier frequency stability (EDR) Receive sensitivity 1 Maximum input signal level Bandwidth between the +/- 20 db down points of the modulation waveform Spurious emission measured at +/- 5 MHz of DUT TX frequency only Average and peak frequency deviation (Hz) Carrier frequency offset (Hz) Carrier frequency change over the Bluetooth burst (Hz) Average power of complete data capture (dbm) Frequency drift over the Bluetooth EDR burst duration (Hz) Receive sensitivity test using LitePoint or usergenerated waveforms. Includes Dirty Packets. Assuming single-ended BER measurement VSA frequency accuracy: ± 0.2 ppm calibrated VSA spurious: < -50 dbc (50 khz RBW) (CW) (For EVM better than -25 db) VSA measurement error: ± 0.2 ppm calibrated VSA power accuracy: ± 0.75 db (+20 to -35 dbm) VSG power accuracy: ± 0.75 db (+ 5 to -95 dbm) RMS EVM (EDR) RMS EVM for Bluetooth EDR Residual VSA EVM: -35 db (+20 to -25 dbm) Peak EVM (EDR) Peak EVM for Bluetooth EDR Residual VSG EVM: -35 db (-5 to -70 dbm) 1 IQxel-M support testing sensitivity with Dirty Packets Multi-DUT/Multicom Connectivity Test System 9

10 Bluetooth (4.0, 4.1, 4.2) Measurement Specifications Measurement Description Performance Output power at NOC 1 Output power at EOC 1 In-band emissions at NOC 1 Spurious emission measured at +/- 5 In-band emissions at EOC 1 MHz of DUT TX frequency only VSA power accuracy: ± 0.75 db (+20 to -35 dbm) VSA spurious: < -50 dbc (50 khz RBW) (CW) Modulation characteristics Carrier frequency offset and drift at NOC 1 Carrier frequency offset and drift at EOC 1 Receiver sensitivity at NOC 1,2 Receiver sensitivity at EOC 1,2 C/I and receiver selectivity performance 3 Blocking performance 3 Intermodulation performance Maximum input signal level PER report integrity Average and peak frequency deviation (Hz) Carrier frequency offset (Hz) and change over the Bluetooth burst (Hz) Receive sensitivity test using LitePoint or user-generated waveforms Assuming single-ended BER measurement Verifies the DUT PER report mechanism VSA frequency accuracy: ± 0.2 ppm calibrated VSG power accuracy: ± 0.75 db (+ 5 to -95 dbm) VSA spurious: < -50 dbc (50 khz RBW) (CW) VSG maximum output power: +9 to -95 dbm CW 0 to -95 dbm modulated 1 NOC and EOC tests are the same except for the operating conditions which do not impact the test equipment requirements 2 External signal source required for these measurements (not LitePoint supplied) 3 IQxel-M provide the wanted signal only. No interfering signal is available Multi-DUT/Multicom Connectivity Test System 10

11 Bluetooth 5 Measurement Specifications Bluetooth 5 introduced a couple of new test requirements: Data Rate: New requirements for testing with 2 Mbps, 1 Mbps, 500 kbps, 125 kbps signal Stable Modulation: Optional requirement for device to support smaller variation in the frequency deviation during modulation (modulation index between ). This enhancement gives device stable and better range coverage and thus competitive advantage IQxel-M is capable of testing for these new requirements Measurement Description Performance In-band emissions Modulation Characteristics Carrier Frequency offset and drift Stable Modulation Characteristics Spurious emission measured at ± 5 MHz of DUT TX frequency only. Tested at 1 Mbps, 2 Mbps Average and peak frequency deviation (Hz). Tested at 1 Mbps, 2 Mbps, 125 kbps Carrier frequency offset (Hz) and change over the Bluetooth burst (Hz). Tested at 1 Mbps, 2 Mbps, 125 kbps Tested at 1 Mbps, 2 Mbps VSA spurious: < -50 dbc (50 khz RBW) (CW) VSA frequency accuracy: ± 0.2 ppm calibrated VSA frequency accuracy: ± 0.2 ppm calibrated Receiver Sensitivity Receiver Sensitivity Stable Modulation Index Receive sensitivity test using LitePoint or user-generated waveforms. Tested at 1 Mbps, 2 Mbps, 125 kbps VSG power accuracy: ± 0.75 db (+ 5 to -95 dbm) Tested at 1 Mbps, 2 Mbps, 500 kbps, 125 kbps Maximum Input signal level Maximum Input signal level Stable Modulation Index C/I and Receiver Selectivity Performance Blocking Performance Intermodulation Performance PER Report Integrity Assuming single-ended BER measurement. Tested at 1 Mbps, 2 Mbps Tested at 1 Mbps, 2 Mbps Tested at 1 Mbps, 2 Mbps, 500 kbps, 125 kbps Tested at 1 Mbps, 2 Mbps Tested at 1 Mbps, 2 Mbps Verifies the DUT PER report mechanism. Tested at 1 Mbps, 2 Mbps,500 kbps, 125 kbps VSG maximum output power: +9 to -95 dbm CW 0 to -95 dbm modulated VSA spurious: < -50 dbc (50 khz RBW) (CW) Multi-DUT/Multicom Connectivity Test System 11

12 ZigBee ( ) Measurement Description Performance Output power Transmit DUT output power (dbm) VSA power accuracy: ± 0.75 db (+20 to -35 dbm) Power spectral density Transmit DUT power spectral density ± 0.50 db (+20 to -35 dbm) typical Center Frequency Tolerance EVM Other modulation quality measurements CCDF (complementary cumulative distribution function) Tx center frequency tolerance Offset: compensate the I and Q offset in OQPSK Normal: no compensation applied LO leakage, clock error, phase error, symbol clock error Probability of peak signal power being greater than a given power level versus peak-to-average power ratio (db) VSA frequency accuracy: ± 0.2 ppm calibrated Z-Wave (ITU-T G.9959) Measurement Description Performance Output Power TX output power (dbm) VSA power accuracy: +/ db (+20 to -35 dbm) Power Spectral Density TX power spectral density +/ db (+20 to -35 dbm) typical Carrier Frequency Offset Frequency Deviation TX center frequency error RMS, Min, Max Frequency Deviation VSA frequency accuracy: <= +/- 0.2 ppm calibrated Symbol Clock Error Symbol Clock Error and Jitter VSG output power: +9 to -95 dbm CW RX Power Level RF Generator Output Level Range 0 to -95 dbm modulated WiSUN MR-FSK ( g) Measurement Description Performance Output Power TX output power (dbm) VSA power accuracy: +/ db (+20 to -35 dbm) Power Spectral Density TX power spectral density +/ db (+20 to -35 dbm) typical Carrier Frequency Offset Frequency Deviation Symbol Clock Error RX Power Level TX center frequency error RMS, Min, Max Frequency Deviation Symbol Clock Error and Jitter RF Generator Output Level Range VSA frequency accuracy: <= +/- 0.2 ppm calibrated VSG output power: +9 to -95 dbm CW 0 to -95 dbm modulated Multi-DUT/Multicom Connectivity Test System 12

13 DECT (ETSI EN ) Measurement Description Performance Power Normal Transmit Power VSA power accuracy: ± 0.75 db (+20 to -35 dbm) Power vs. time Power time template ± 0.50 db (+20 to -35 dbm) typical Frequency offset Frequency drift Frequency deviation Frequency offset Frequency drift during packet transmission S field, B field, whole packet VSA frequency accuracy: ± 0.2 ppm calibrated LET-U Small Cell Standard Test LTE Small Cell 3GPP TS Maximum Output Power Frequency Error Occupied Bandwidth Adjacent Channel Leakage Ratio Error Vector Magnitude Spectrum Emissions 6.2.6, 6.2.7, 6.6.3, Transmitter OFF power MIMO System Performance The additional specifications in the table below apply to the complete IQxel MIMO system. Parameter Port Designations Range VSA capture trigger accuracy VSA start trigger accuracy ± 3.5 ns ± 3.5 ns Multi-DUT/Multicom Connectivity Test System 13

14 Port Descriptions Front Panel I/O Function Type Power switch Power on/off Pushbutton switch RF1 RF4 VSA/VSG N female GNSS Global Navigation Satellite System Signal Out N female LFC Low frequency Communication (broadcast standard) Signal Out N female Power indicator Session active indicator Status indicator GNSS/LFC indicator RF port 1 indicator RF port 2 indicator RF port 3 indicator RF port 4 indicator LED off - AC switch on the back panel is turned off or the AC power cable is not connected LED solid red - test system is in standby mode LED blinking red - test system is powering off LED blinking green - test system is booting up LED solid green - test system is powered on LED green - remote session active LED red - remote session lock LED green - no faults/errors detected LED orange - Software error detected LED red - Hardware fault detected LED green - GNSS on LED orange - LFC on LED red - both GNSS and LFC on LED green - port is a VSA input LED red - port is a VSG output LED green - port is a VSA input LED red - port is a VSG output LED green - port is a VSA input LED red - port is a VSG output LED green - port is a VSA input LED red - port is a VSG output LED indicator LED indicator LED indicator LED indicator LED indicator LED indicator LED indicator LED indicator USB (2 ports) USB 2.0 compatible connection to external controller USB Type A Multi-DUT/Multicom Connectivity Test System 14

15 Rear Panel General I/O I/O Function Type 10 MHz ref input The 10 MHz reference input has a 200 ohm impedance and accepts a sine wave ranging in amplitude from 0.3 Vpp to 4 Vpp. BNC female 10 MHz ref output 10 MHz reference output BNC female Marker out / trigger in 1 TTL compatible BNC female Marker out / trigger in 2 TTL compatible BNC female Marker out / trigger in 3 TTL compatible BNC female Marker out / trigger In 4 TTL compatible BNC female USB (2 ports) USB 2.0 compatible connection to external controller USB Type A AC in AC power input 100 to 240VAC (automatically switched) 50 to 60 Hz Includes hard power switch DVI port Display LitePoint monitor DVI-D VGA port Display LitePoint monitor VGA-15 pin Communication I/O LAN 1000 Base-T LAN RJ-45 Multi-DUT/Multicom Connectivity Test System 15

16 General and Environmental Dimensions Weight Power requirements Power consumption Recommended PC Recommended browser for optimal performance Unit with handle: 15.5 W x 3.2 H x 20 D (370 mm W x 82 mm H x 508 mm D) Unit without handle: 14.7 W x 3.2 H x 17.1 D (373 mm W x 82 mm H x 434 mm D) kg (25.2 pounds), 6 port 100 to 240 VAC, < 300 W, 50 to 60 Hz <235 W (maximum), <10 W (standby) Intel Core i5 2.5 GHz with 1 GB of RAM or better Google Chrome R10 Release Operating temperature +10 C to +55 C (IEC EN , 2, 14) Storage temperature -20 C to +70 C (IEC EN , 2, 14) Specification validity temperature Operating humidity EMC +20 C to +30 C 15% to 95% relative humidity, non-condensing (IEC EN ) EN Immunity for industrial environment, Class A emissions Safety IEC , EN , UL3111-1, CAN/CSA-C22.2 No Mechanical vibration IEC 60068, IEC and MIL-T-28800D, class 5 Mechanical shock Recommended calibration cycle Warranty ASTM D , Method B 12 months 12 months hardware 12 months software updates Multi-DUT/Multicom Connectivity Test System 16

17 Copyright 2017 LitePoint, A Teradyne Company. All rights reserved RESTRICTED RIGHTS LEGEND No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written permission of LitePoint Corporation. DISCLAIMER LitePoint Corporation makes no representations or warranties with respect to the contents of this manual or of the associated LitePoint Corporation products, and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. LitePoint Corporation shall under no circumstances be liable for incidental or consequential damages or related expenses resulting from the use of this product, even if it has been notified of the possibility of such damages. If you find errors or problems with this documentation, please notify LitePoint Corporation at the address listed below. LitePoint Corporation does not guarantee that this document is errorfree. LitePoint Corporation reserves the right to make changes in specifications and other information contained in this document without prior notice. TRADEMARKS LitePoint and the LitePoint logo are registered trademarks of LitePoint Corporation. IQxel-M is a trademark of LitePoint Corporation. All other trademarks or registered trademarks are owned by their respective owners. CONTACT INFORMATION LitePoint Corporation 575 Maude Court Sunnyvale, CA United States of America LITEPOINT TECHNICAL SUPPORT Doc: June 2017 Rev 17

IQxel-M8 TM Multi-DUT Connectivity Test System

IQxel-M8 TM Multi-DUT Connectivity Test System TECHNICAL SPECIFICATIONS IQxel-M8 TM Multi-DUT Connectivity Test System 2017 LitePoint, A Teradyne Company. All rights reserved. Overview of IQxel-M8 The IQxel-M8 is a manufacturing oriented, Multi-DUT

More information

IQxel-M8 TM Multi-DUT Connectivity Test System

IQxel-M8 TM Multi-DUT Connectivity Test System TECHNICAL SPECIFICATIONS IQxel-M8 TM Multi-DUT Connectivity Test System 2015 LitePoint, A Teradyne Company. All rights reserved. Overview of IQxel-M8 The IQxel-M8 is a manufacturing oriented, Multi-DUTtest

More information

IQxel-M TM Multi-DUT/Multicom Connectivity Test System

IQxel-M TM Multi-DUT/Multicom Connectivity Test System TECHNICAL SPECIFICATIONS IQxel-M TM Multi-DUT/Multicom Connectivity Test System 2013 LitePoint, A Teradyne Company. All rights reserved. Overview of IQxel-M The IQxel-M is a manufacturing oriented, Multi-DUT,

More information

IQxel-M8W TM Multi-DUT Connectivity Test System

IQxel-M8W TM Multi-DUT Connectivity Test System TECHNICAL SPECIFICATIONS IQxel-M8W TM Multi-DUT Connectivity Test System 2018 LitePoint, A Teradyne Company. All rights reserved. General Technical Specifications RF Analyzer Parameter Ports (A/B) Value

More information

IQxel TM Next Generation Connectivity Test System

IQxel TM Next Generation Connectivity Test System TECHNICAL SPECIFICATIONS IQxel TM Next Generation Connectivity Test System 2017 LitePoint, A Teradyne Company. All rights reserved. General Technical Specifications RF Analyzer Parameter Ports Value Input

More information

IQgig-IF TM Technical Specifications

IQgig-IF TM Technical Specifications TECHNICAL SPECIFICATIONS IQgig-IF TM Technical Specifications 2018 LitePoint, A Teradyne Company. All rights reserved. Port Descriptions IQgig-IF Front Panel I/O Function Type Power Switch Power On/Off

More information

IQxel-M2W TM R&D Connectivity Test System for Next Generation of Wi-Fi

IQxel-M2W TM R&D Connectivity Test System for Next Generation of Wi-Fi TECHNICAL SPECIFICATIONS IQxel-M2W TM R&D Connectivity Test System for Next Generation of Wi-Fi 2019 LitePoint, A Teradyne Company. All rights reserved. General Technical Specifications RF Analyzer Parameter

More information

IQxel-M8W TM Multi-DUT Connectivity Test System

IQxel-M8W TM Multi-DUT Connectivity Test System TECHNICAL SPECIFICATIONS IQxel-M8W TM Multi-DUT Connectivity Test System 2019 LitePoint, A Teradyne Company. All rights reserved. General Technical Specifications RF Analyzer Parameter Ports (A/B) Value

More information

IQgig-RF TM Model B Technical Specifications

IQgig-RF TM Model B Technical Specifications TECHNICAL SPECIFICATIONS IQgig-RF TM Model B Technical Specifications 2018 LitePoint, A Teradyne Company. All rights reserved. Port Descriptions IQgig-RF Test Controller Front Panel I/O Function Type Power

More information

IQgig-RF TM Technical Specifications

IQgig-RF TM Technical Specifications TECHNICAL SPECIFICATIONS IQgig-RF TM Technical Specifications 2017 LitePoint, A Teradyne Company. All rights reserved. IQgig-RF is a scalable physical-layer test solution, tailored for 802.11ad (WiGig)

More information

LitePoint IQxstream-M

LitePoint IQxstream-M TECHNICAL SPECIFICATIONS LitePoint IQxstream-M 2017 LitePoint, A Teradyne Company. All rights reserved. IQxstream-M is a manufacturing-oriented, multi-device, physical layer communication system tester,

More information

IQ2015 TM Connectivity Test System

IQ2015 TM Connectivity Test System TECHNICAL SPECIFICATIONS IQ2015 TM Connectivity Test System 2014 LitePoint, A Teradyne Company. All rights reserved. General Technical Specifications Analyzer Parameter Port Designations Range Input frequency

More information

IQcell TM Technical Specifications

IQcell TM Technical Specifications TECHNICAL SPECIFICATIONS IQcell TM Technical Specifications 2017 LitePoint, A Teradyne Company. All rights reserved. IQcell is a highly-integrated, manufacturing optimized, multi-dut signaling test set,

More information

DATA SHEET. LitePoint IQflex LitePoint Corporation. All rights reserved.

DATA SHEET. LitePoint IQflex LitePoint Corporation. All rights reserved. DATA SHEET 2011 LitePoint Corporation. All rights reserved. Introduction The IQflex 802.11a/b/g/n WLAN and Bluetooth Test Solution is an all-in-one test instrument developed specifically for RF testing

More information

TECHNICAL SPECIFICATIONS. LitePoint IQxstream LitePoint, A Teradyne Company. All rights reserved.

TECHNICAL SPECIFICATIONS. LitePoint IQxstream LitePoint, A Teradyne Company. All rights reserved. TECHNICAL SPECIFICATIONS LitePoint IQxstream 2017 LitePoint, A Teradyne Company. All rights reserved. IQxstream is a manufacturing oriented, physical layer communication system tester, tailored to verifying

More information

LitePoint IQ201X Connectivity Test System

LitePoint IQ201X Connectivity Test System DATA SHEET LitePoint IQ201X Connectivity Test System 2011 LitePoint Corporation. All rights reserved. Table of Contents Introduction... 2 Features... 2 Basic Functional Description... 3 Typical Scenario

More information

IQ2015 Connectivity Test System

IQ2015 Connectivity Test System BROCHURE IQ2015 Connectivity Test System TM 2014 LitePoint, A Teradyne Company. All rights reserved. Introduction LitePoint s IQ2015 Connectivity Test System is the first product to specifically address

More information

z8801 Local Oscillator PXI

z8801 Local Oscillator PXI TECHNICAL SPECIFICATIONS z8801 Local Oscillator PXI 2014 LitePoint, A Teradyne Company. All rights reserved. Port Descriptions Front Panel Label Type Description REF OUT SMA Backplane reference clock output

More information

LitePoint IQnxn MIMO Test Solution

LitePoint IQnxn MIMO Test Solution DATA SHEET LitePoint IQnxn MIMO Test Solution 2011 LitePoint Corporation. All rights reserved. Revision History Release Date Revision Change Description Jan 20, 2006 1.0 First Release April 6, 2007 2.1

More information

Reconfigurable 6 GHz Vector Signal Transceiver with I/Q Interface

Reconfigurable 6 GHz Vector Signal Transceiver with I/Q Interface SPECIFICATIONS PXIe-5645 Reconfigurable 6 GHz Vector Signal Transceiver with I/Q Interface Contents Definitions...2 Conditions... 3 Frequency...4 Frequency Settling Time... 4 Internal Frequency Reference...

More information

PXIe Contents SPECIFICATIONS. 14 GHz and 26.5 GHz Vector Signal Analyzer

PXIe Contents SPECIFICATIONS. 14 GHz and 26.5 GHz Vector Signal Analyzer SPECIFICATIONS PXIe-5668 14 GHz and 26.5 GHz Vector Signal Analyzer These specifications apply to the PXIe-5668 (14 GHz) Vector Signal Analyzer and the PXIe-5668 (26.5 GHz) Vector Signal Analyzer with

More information

z48831 / z :1/ 16:1 6 GHz Multiplexer Module

z48831 / z :1/ 16:1 6 GHz Multiplexer Module TECHNICAL SPECIFICATIONS z48831 / z48832 8:1/ 16:1 6 GHz Multiplexer Module 2017 LitePoint, A Teradyne Company. All rights reserved. Port Descriptions Front Panel Label Type Description 1-16 SMA RF1 to

More information

z475 Remote DC Power Supply Preliminary

z475 Remote DC Power Supply Preliminary TECHNICAL SPECIFICATIONS z475 Remote DC Power Supply Preliminary 2018 LitePoint, A Teradyne Company. All rights reserved. Overview The z475 remote DC Power supply can provide a stable VCC voltage for PA/FEM/SW

More information

Vector Network Analyzers ZVB

Vector Network Analyzers ZVB Specifications Version 05.00 Vector Network Analyzers ZVB September 2005 Specifications MEASUREMENT RANGE...3 MEASUREMENT SPEED...5 MEASUREMENT ACCURACY...6 EFFECTIVE SYSTEM DATA...8 TEST PORT OUTPUT...8

More information

R&S ZVT Vector Network Analyzer Specifications

R&S ZVT Vector Network Analyzer Specifications R&S ZVT Vector Network Analyzer Specifications Test & Measurement Data Sheet 08.00 CONTENTS Definitions... 3 Specifications... 4 Measurement range...4 Measurement speed...5 Measurement accuracy...6 Effective

More information

Power Amplifier Testing For ac APPLICATION NOTE

Power Amplifier Testing For ac APPLICATION NOTE Power Amplifier Testing For 802.11ac APPLICATION NOTE Using z8201 RF Test Set & zprotocol WLAN Software Introduction The first Wireless LAN (WLAN) standards were used primarily to provide low data rate

More information

VIAVI VST. Data Sheet. 6 GHz RF Vector Signal Transceiver (VST)

VIAVI VST. Data Sheet. 6 GHz RF Vector Signal Transceiver (VST) Data Sheet VIAVI 6 GHz RF Vector Signal Transceiver () VIAVI Solutions The Vector Signal Transceiver () is an essential building block in RF communications test solutions supplied by VIAVI Solutions. Overview

More information

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc. SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter Datasheet Rev 1.2 2017 SignalCore, Inc. support@signalcore.com P R O D U C T S P E C I F I C A T I O N S Definition of Terms The following terms are used

More information

TC-3000C Bluetooth Tester

TC-3000C Bluetooth Tester TC-3000C Bluetooth Tester Product Instructions TC-3000C Bluetooth Tester is able to analyze the data of every packet that is transmitted to the upper application protocol layer using the protocol stack,

More information

z488xx RF Switches/Multiplexers PXI

z488xx RF Switches/Multiplexers PXI TECHNICAL SPECIFICATIONS z488xx RF Switches/Multiplexers PXI 2014 LitePoint, A Teradyne Company. All rights reserved. Port Descriptions z488xx includes the z48801 Dual Single Pole Double Throw (SPDT),

More information

z8551 I/Q Waveform Generator PXI, PXIe

z8551 I/Q Waveform Generator PXI, PXIe TECHNICAL SPECIFICATIONS z8551 I/Q Waveform Generator PXI, PXIe 2014 LitePoint, A Teradyne Company. All rights reserved. Port Descriptions Front Panel Label Type Description I OUT +,- SMA Differential

More information

VST 6 GHz RF Vector Signal Transceiver (VST)

VST 6 GHz RF Vector Signal Transceiver (VST) VST 6 GHz RF Vector Signal Transceiver (VST) 2016 Datasheet The most important thing we build is trust Key features Vector signal analyser and generator in a single 3U x 3 slot wide PXIe module 65 MHz

More information

MG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz

MG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz Data Sheet MG3740A Analog Signal Generator 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz Contents Definitions, Conditions of Specifications... 3 Frequency... 4 Output Level... 5 ATT Hold...

More information

z47524 PXI Quad SPDT RF Changeover Switch Module

z47524 PXI Quad SPDT RF Changeover Switch Module TECHNICAL SPECIFICATIONS z47524 PXI Quad SPDT RF Changeover Switch Module 2017 LitePoint, A Teradyne Company. All rights reserved. Overview The z47524 PXI RF switching module has a bank of four individual

More information

Keysight Technologies N9320B RF Spectrum Analyzer

Keysight Technologies N9320B RF Spectrum Analyzer Keysight Technologies N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has

More information

Agilent N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer Agilent N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has been turned

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent N4010A Wireless Connectivity Test Set and N4011A MIMO/Multi-port Adapter Data Sheet N4010A Introduction The

More information

2012 LitePoint Corp LitePoint, A Teradyne Company. All rights reserved.

2012 LitePoint Corp LitePoint, A Teradyne Company. All rights reserved. LTE TDD What to Test and Why 2012 LitePoint Corp. 2012 LitePoint, A Teradyne Company. All rights reserved. Agenda LTE Overview LTE Measurements Testing LTE TDD Where to Begin? Building a LTE TDD Verification

More information

Agilent N4010A Wireless Connectivity Test Set and N4011A MIMO/Multi-port Adapter

Agilent N4010A Wireless Connectivity Test Set and N4011A MIMO/Multi-port Adapter Agilent N4010A Wireless Connectivity Test Set and N4011A MIMO/Multi-port Adapter Data Sheet N4010A Introduction The Agilent N4010A Wireless Connectivity Test Set is a measurement solution that enables

More information

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC Model 845-HP Datasheet Model 745 Series Portable 20+ GHz Microwave Signal Generator High Power +23dBM Power Output 250 fs Digital Delay Generator BNC Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation

More information

PXI WLAN Measurement Suite Data Sheet

PXI WLAN Measurement Suite Data Sheet PXI WLAN Measurement Suite Data Sheet The most important thing we build is trust Bench-top R&D and production ready ATE RF performance verification tools Multi device parallel testing for higher production

More information

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved Data Sheet SC5317 & SC5318A 6 GHz to 26.5 GHz RF Downconverter www.signalcore.com 2018 SignalCore, Inc. All Rights Reserved Definition of Terms 1 Table of Contents 1. Definition of Terms... 2 2. Description...

More information

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc.

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc. SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module Datasheet 2015 SignalCore, Inc. support@signalcore.com SC5306B S PECIFICATIONS Definition of Terms The following terms are used throughout this datasheet

More information

TETRA Tx Test Solution

TETRA Tx Test Solution Product Introduction TETRA Tx Test Solution Signal Analyzer Reference Specifications ETSI EN 300 394-1 V3.3.1(2015-04) / Part1: Radio ETSI TS 100 392-2 V3.6.1(2013-05) / Part2: Air Interface May. 2016

More information

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc. SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter Datasheet 2017 SignalCore, Inc. support@signalcore.com P RODUCT S PECIFICATIONS Definition of Terms The following terms are used throughout this datasheet

More information

R&S ZNC Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement

More information

Full system level calibration (levels, s-parameters, noise) Full RF source and measure capability Applications Vector network analyzer capability

Full system level calibration (levels, s-parameters, noise) Full RF source and measure capability Applications Vector network analyzer capability Semiconductor Test AXRF - Multi-Port PXI RF Subsystem Modulated Vector Source and Measurement Data Sheet The most important thing we build is trust Functionality High speed, reliable solid state design

More information

Spectrum Analyzer R&S FS300

Spectrum Analyzer R&S FS300 Spectrum Analyzer R&S FS300 9 khz to 3 GHz The new product family from Rohde & Schwarz Professional test equipment for laboratory, service and production The R&S FS300 is a highly accurate spectrum analyzer

More information

PXI LTE/LTE-A Downlink (FDD and TDD) Measurement Suite Data Sheet

PXI LTE/LTE-A Downlink (FDD and TDD) Measurement Suite Data Sheet PXI LTE/LTE-A Downlink (FDD and TDD) Measurement Suite Data Sheet The most important thing we build is trust Designed for the production test of the base station RF, tailored for the evolving small cell

More information

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB SYNTHESIZED SIGNAL GENERATOR MG3633A GPIB For Evaluating of Quasi-Microwaves and Measuring High-Performance Receivers The MG3633A has excellent resolution, switching speed, signal purity, and a high output

More information

Spectrum Analyzers 2680 Series Features & benefits

Spectrum Analyzers 2680 Series Features & benefits Data Sheet Features & benefits n Frequency range: 9 khz to 2.1 or 3.2 GHz n High Sensitivity -161 dbm/hz displayed average noise level (DANL) n Low phase noise of -98 dbc/hz @ 10 khz offset n Low level

More information

R&S CMW500 Wideband Radio Communication Tester Specifications

R&S CMW500 Wideband Radio Communication Tester Specifications R&S CMW500 Wideband Radio Communication Tester Specifications Test & Measurement Data Sheet 06.00 CONTENTS General technical specifications... 6 RF generator...6 Modulation source: arbitrary waveform generator

More information

Agilent 8657A/8657B Signal Generators

Agilent 8657A/8657B Signal Generators Agilent / Signal Generators Profile Spectral performance for general-purpose test Overview The Agilent Technologies and signal generators are designed to test AM, FM, and pulsed receivers as well as components.

More information

R&S CMW100 Communications Manufacturing Test Set Specifications

R&S CMW100 Communications Manufacturing Test Set Specifications R&S CMW100 Communications Manufacturing Test Set Specifications Data Sheet Version 02.00 CONTENTS Definitions... 6 General technical specifications... 7 RF generator... 8 Modulation source: arbitrary waveform

More information

R&S CMW100 Communications Manufacturing Test Set Specifications

R&S CMW100 Communications Manufacturing Test Set Specifications R&S CMW100 Communications Manufacturing Test Set Specifications R&S CMW100 model.k06 Data Sheet Version 03.00 CONTENTS Definitions... 4 General technical specifications... 5 RF generator... 6 RF analyzer...

More information

R&S SMB100N SIGNAL GENERATOR

R&S SMB100N SIGNAL GENERATOR R&S SMB100N SIGNAL GENERATOR PERFORMANCE SPECIFICATIONS VERSION 02.00, SEPTEMBER 2009 CONTENTS Specifications...3 Definitions... 3 RF performance... 4 Frequency... 4 Frequency sweep... 4 Reference frequency...

More information

Agilent E6651A Mobile WiMAX Test Set

Agilent E6651A Mobile WiMAX Test Set Agilent E6651A Mobile WiMAX Test Set Preliminary Technical Overview Accelerate time-to-market for your IEEE802.16e subscriber station designs The E6651A represents a significant breakthrough in Mobile

More information

FREEDOM Communications System Analyzer R8100 DATA SHEET

FREEDOM Communications System Analyzer R8100 DATA SHEET FREEDOM Communications System Analyzer R8100 DATA SHEET Table of Contents Operating/Display Modes 3 General 3 Generator (Receiver Test) 4 Receiver (Transmitter Test) 5 Spectrum Analyzer 6 Oscilloscope

More information

R&S ZNB Vector Network Analyzer Specifications

R&S ZNB Vector Network Analyzer Specifications Umschlag_ZNB4-8_dat-sw_en_5214-5384-22.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNB Vector Network Analyzer Specifications 07.11.2011 10:03:35 CONTENTS Definitions... 3 Measurement range... 4 Measurement

More information

Chapter 6 Specifications

Chapter 6 Specifications RIGOL This chapter describes the specifications of RF signal generator. Specifications are valid under the following conditions: the instrument in the calibration cycle is stored at least two hours at

More information

PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet

PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet The most important thing we build is trust 250 MHz to 6 GHz RF signal conditioning module for multi- UE, MIMO and Smartphone testing Four full

More information

Chapter 6 Specifications

Chapter 6 Specifications RIGOL This chapter lists the technical specifications and general specifications of the RF signal generator. The technical specifications are valid when the instrument is within the calibration period,

More information

DSA700 Series Spectrum Analyzer

DSA700 Series Spectrum Analyzer DSA700 Series Spectrum Analyzer Product Features: All-Digital IF Technology Frequency Range from 100 khz up to 1 GHz Min. -155 dbm Displayed Average Noise Level (Typ.) Min.

More information

Chapter 5 Specifications

Chapter 5 Specifications RIGOL Specifications are valid under the following conditions: the instrument is within the calibration period, is stored for at least two hours at 0 to 50 temperature and is warmed up for 40 minutes.

More information

PXI Modules 3070A PXI High Performance RF Digitizer Data Sheet

PXI Modules 3070A PXI High Performance RF Digitizer Data Sheet PXI Modules 3070A PXI High Performance RF Digitizer Data Sheet The most important thing we build is trust Continuous frequency range 250 MHz to 3 GHz or 6 GHz Input levels to +30 dbm with 1 db RF step

More information

Model 855 RF / Microwave Signal Generator

Model 855 RF / Microwave Signal Generator Features Very low phase noise Fast switching Phase coherent switching option 2 to 8 phase coherent outputs USB, LAN, GPIB interfaces Applications Radar simulation Quantum computing High volume automated

More information

z8751 Vector Signal Generator PXI, PXIe

z8751 Vector Signal Generator PXI, PXIe TECHNICAL SPECIFICATIONS z8751 Vector Signal Generator PXI, PXIe 2014 LitePoint, A Teradyne Company. All rights reserved. Port Descriptions Front Panel Label Type Description I OUT +,- SMA Differential

More information

Preliminary. PXI PRELIMINARY 3041 Small Cell RF Tester Data Sheet. The most important thing we build is trust. Test up to 4 small cells in parallel

Preliminary. PXI PRELIMINARY 3041 Small Cell RF Tester Data Sheet. The most important thing we build is trust. Test up to 4 small cells in parallel PXI PRELIMINARY 3041 Small Cell RF Tester Data Sheet The most important thing we build is trust Turnkey production ATE solution for testing Small Cell base stations Automated Tx and Rx RF alignment and

More information

PXI WiMAX Measurement Suite Data Sheet

PXI WiMAX Measurement Suite Data Sheet PXI WiMAX Measurement Suite Data Sheet The most important thing we build is trust Transmit power Spectral mask Occupied bandwidth EVM (all, data only, pilots only) Frequency error Gain imbalance, Skew

More information

R&S ZVT Vector Network Analyzer Specifications

R&S ZVT Vector Network Analyzer Specifications ZVT_dat-sw_en_0758-065-22_v0900_cover.indd Data Sheet 09.00 Test & Measurement R&S ZVT Vector Network Analyzer Specifications 06.03.205 5:50:4 CONTENTS Definitions... 3 Specifications... 4 Measurement

More information

R3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation

R3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation R3477 Signal Analyzers Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation Frequency range: 9 khz to 13.5 GHz World

More information

FREEDOM Communications System Analyzer R8100 DATA SHEET

FREEDOM Communications System Analyzer R8100 DATA SHEET FREEDOM Communications System Analyzer R8100 DATA SHEET Table of Contents Operating/Display Modes 3 General 3 Generator (Receiver Test) 4 Receiver (Transmitter Test) 5 Spectrum Analyzer 6 Oscilloscope

More information

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Model 865 RF / Ultra Low Noise Microwave Signal Generator Model 865 RF / Ultra Low Noise Microwave Signal Generator Features Excellent signal purity: ultra-low phase noise and low spurious Combination of highest output power and fastest switching Powerful touch-display

More information

WaveStation Function/Arbitrary Waveform Generators

WaveStation Function/Arbitrary Waveform Generators WaveStation Function/Arbitrary Waveform Generators Key Features High performance with 14-bit, 125 MS/s and 16 kpts 2 channels on all models Large 3.5 color display for easy waveform preview Over 40 built-in

More information

Spectrum Analyzer FSL

Spectrum Analyzer FSL Specifications Version 02.00 Spectrum Analyzer FSL August 2005 Specifications Specifications Specifications apply under the following conditions: 15 minutes warm-up time at ambient temperature, specified

More information

PXI LTE FDD and LTE TDD Measurement Suites Data Sheet

PXI LTE FDD and LTE TDD Measurement Suites Data Sheet PXI LTE FDD and LTE TDD Measurement Suites Data Sheet The most important thing we build is trust A production ready ATE solution for RF alignment and performance verification UE Tx output power Transmit

More information

Specification RIGOL. 6 Specification

Specification RIGOL. 6 Specification Specification RIGOL 6 Specification This chapter lists the specifications and general specifications of the analyzer. All the specifications are guaranteed when the following conditions are met unless

More information

2026Q CDMA/GSM Interferer MultiSource Generator

2026Q CDMA/GSM Interferer MultiSource Generator Signal Sources 2026Q CDMA/GSM Interferer MultiSource Generator The 2026Q is designed to work with a radio test set to provide a fully integrated radio receiver test solution for cellular and PCS systems

More information

LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz

LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz Datasheet The LNS is an easy to use 18 GHz synthesizer that exhibits outstanding phase noise and jitter performance in a 3U rack mountable chassis.

More information

FREEDOM Communications System Analyzer R8600 DATA SHEET

FREEDOM Communications System Analyzer R8600 DATA SHEET FREEDOM Communications System Analyzer R8600 DATA SHEET Table of Contents Operating/Display Modes 3 General 3 Generator (Receiver Test) 4 Receiver (Transmitter Test) 5 Spectrum Analyzer 6 Oscilloscope

More information

R&S CBT/R&S CBT32 Bluetooth Tester Specifications

R&S CBT/R&S CBT32 Bluetooth Tester Specifications Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) R&S CBT/R&S CBT32 Bluetooth Tester Specifications Test & Measurement Data Sheet 06.00 CONTENTS Unit specifications...

More information

Model MHz Arbitrary Waveform Generator Specifications

Model MHz Arbitrary Waveform Generator Specifications 50MHz Arbitrary Waveform Generator s DISPLAY: Graph mode for visual verification of signal settings. CAPABILITY: Standard waveforms: Sine, Square, Ramp, Triangle, Pulse, Noise, DC Built-in arbitrary waveforms:

More information

FREEDOM Communications System Analyzer R8000C DATA SHEET

FREEDOM Communications System Analyzer R8000C DATA SHEET FREEDOM Communications System Analyzer R8000C DATA SHEET Table of Contents Operating/Display Modes 3 General 3 Generator (Receiver Test) 4 Receiver (Transmitter Test) 5 Spectrum Analyzer 6 Oscilloscope

More information

WaveStation Function/Arbitrary Waveform Generators

WaveStation Function/Arbitrary Waveform Generators WaveStation Function/Arbitrary Waveform Generators Key Features High performance with 14-bit, 125 MS/s and 16 kpts 2 channels on all models Large 3.5 color display for easy waveform preview Over 40 built-in

More information

3250 Series Spectrum Analyzer

3250 Series Spectrum Analyzer The most important thing we build is trust ADVANCED ELECTRONIC SOLUTIONS AVIATION SERVICES COMMUNICATIONS AND CONNECTIVITY MISSION SYSTEMS 3250 Series Spectrum Analyzer > Agenda Introduction

More information

khz to 2.9 GHz Spectrum Analyzer

khz to 2.9 GHz Spectrum Analyzer Spectrum Analyzers 2399 9 khz to 2.9 GHz Spectrum Analyzer A spectrum analyzer with outstanding performance and a user friendly visual interface simplifying many complex measurements. 9 khz to 2.9 GHz

More information

DMR Tx Test Solution. Signal Analyzer MS2830A. Reference Specifications

DMR Tx Test Solution. Signal Analyzer MS2830A. Reference Specifications Product Introduction DMR Tx Test Solution Signal Analyzer MS2830A Reference Specifications ETSI EN 300 113 Version 2.1.1 (2016-08) / Technical characteristics of the transmitter ETSI TS 102 361-1 Version

More information

DG5000 Series Specifications

DG5000 Series Specifications DG5000 Series Specifications All the specifications can be guaranteed if the following two conditions are met unless where noted. The generator is within the calibration period and has performed self-calibration.

More information

2.9GHz SPECTRUM ANALYZER

2.9GHz SPECTRUM ANALYZER 2.9GHz SPECTRUM ANALYZER Introducing a new 2.9GHz Spectrum Analyzer Manufacturing Research and Development Field Service Education Powerful capacity by advanced digital synthesizer Revolutionary features

More information

Frequency range 100 khz to 3 GHz 100 khz to 6 GHz 10 MHz to 18 GHz Reference frequency. 2 ppm in addition 2 ppm/10 C. 0 Hz, 100 Hz to 3 GHz

Frequency range 100 khz to 3 GHz 100 khz to 6 GHz 10 MHz to 18 GHz Reference frequency. 2 ppm in addition 2 ppm/10 C. 0 Hz, 100 Hz to 3 GHz Specifications Specifications apply under the following conditions: 15 minutes warm-up time at ambient temperature, specified environmental conditions met, and calibration cycle adhered to. Data without

More information

WaveStation Function/Arbitrary Waveform Generators

WaveStation Function/Arbitrary Waveform Generators Function/Arbitrary Waveform Generators Key Features High performance with 14-bit waveform generation, up to 500 MS/s sample rate and up to 512 kpts memory 2 channels on all models Large color display for

More information

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ZNBT8 Vector Network Analyzer Specifications E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer

More information

HD Radio FM Transmission System Specifications

HD Radio FM Transmission System Specifications HD Radio FM Transmission System Specifications Rev. D February 18, 2005 Doc. No. SY_SSS_1026s TRADEMARKS The ibiquity Digital logo and ibiquity Digital are registered trademarks of ibiquity Digital Corporation.

More information

Agilent E4428C ESG Analog Signal Generator

Agilent E4428C ESG Analog Signal Generator Migrate to the new Agilent MXG X-Series signal generator and generate true performance The new MXG exceeds the ESG s performance in every category - output power, phase noise, spurious, and low frequency

More information

PXI. TD-SCDMA Measurement Suite Data Sheet. The most important thing we build is trust. Total Average Power plus Midamble / Data Power

PXI. TD-SCDMA Measurement Suite Data Sheet. The most important thing we build is trust. Total Average Power plus Midamble / Data Power PXI TD-SCDMA Measurement Suite Data Sheet The most important thing we build is trust Total Average Power plus Midamble / Data Power Transmit On/Off Time Mask Transmit Closed Loop Power Control (CLPC) Spectrum

More information

Signal Forge 2500M Frequency Expansion Module. 1.5 GHz to 2.6 GHz. User Manual

Signal Forge 2500M Frequency Expansion Module. 1.5 GHz to 2.6 GHz. User Manual TM TM Signal Forge 2500M Frequency Expansion Module 1.5 GHz to 2.6 GHz User Manual Technical Support Email: Support@signalforge.com Phone: 512.275.3733 x2 Contact Information Web: www.signalforge.com Sales

More information

HD Radio FM Transmission. System Specifications

HD Radio FM Transmission. System Specifications HD Radio FM Transmission System Specifications Rev. G December 14, 2016 SY_SSS_1026s TRADEMARKS HD Radio and the HD, HD Radio, and Arc logos are proprietary trademarks of ibiquity Digital Corporation.

More information

TRANSCOM Manufacturing & Education

TRANSCOM Manufacturing & Education www.transcomwireless.com 1 G6 Vector Signal Generator Overview G6 Vector Signal Generator is a high performance vector signal generator. It can generate arbitrary wave signal, continuous wave signal, common

More information

Signal Sources. 2026Q CDMA Interferer Multisource Generator. Advanced Test Equipment Rentals ATEC (2832)

Signal Sources. 2026Q CDMA Interferer Multisource Generator. Advanced Test Equipment Rentals ATEC (2832) Signal Sources Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) 2026Q CDMA Interferer Multisource Generator The 2026Q is designed to work with a radio test set to provide

More information

Application Note. LTE Measurement. MT8820C Radio Communication Analyzer

Application Note. LTE Measurement. MT8820C Radio Communication Analyzer Application Note LTE Measurement MT8820C Radio Communication Analyzer Revision History Ver. No Date Contents Related product software version 1.00 2010/June First edition M882012C/42C Ver. 20.10 2.00 2010/August