Tsunami2 Digital Sound Decoder Electric Technical Reference Software Release 1.2 **
|
|
- Beverley Cobb
- 6 years ago
- Views:
Transcription
1 Tsunami2 Digital Sound Decoder Electric Technical Reference Software Release 12 ** ** Previous software version included Rev C 11/08/17
2 Notice The information in this document is subject to change without notice SoundTraxx (Throttle Up! Corp) shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damage resulting from the furnishing, performance or use of this material This document contains information protected by copyright No part of this document may be photocopied or reproduced in any form without the prior written consent of Throttle Up! Corp Product names mentioned herein may be trademarks and/or registered trademarks of their respective companies SoundTraxx, Econami, Tsunami, Tsunami2, SoundTraxx DCC, Dynamic Digital Exhaust, Auto-Exhaust, Hyperlight, Hyperdrive2, SoundCar, CurrentKeeper and Intelligent Consisting are trademarks of Throttle Up! Corp
3 Contents Primary CVs 6 CV 1: Primary Address 6 CV 2: Vstart 7 CV 3: Baseline Acceleration Rate 8 CV 4: Baseline Deceleration Rate 9 CV 5: Vhigh 10 CV 6: Vmid 11 CV 7: Manufacturer Version (Read-Only) 12 CV 8: Manufacturer ID 13 CV 10: EMF Feedback Cutout 14 CV 11: Packet Time-Out Value 15 CV 12: Alternate Power Source 16 CV 13: Analog Mode Function Enable 1 17 CV 14: Analog Mode Function Enable 2 18 CV 15: CV Unlock Code 19 CV 16: CV Lock ID 20 CVs 17-18: Extended Address 21 CV 19: Consist Address 22 CV 21: Consist Function Enable 1 23 CV 22: Consist Function Enable 2 24 CV 23: Consist Acceleration Rate 25 CV 24: Consist Deceleration Rate 26 CV 25: Speed Table Enable 27 CV 29: Configuration Data 1 28 CV 30: Error Information 29 CV 31: CV Index 1 30 CV 32: CV Index 2 31 CVs 33-46: Function Status CVs 32 CV 33: F0(f) Output Location 33 CV 34: F0(r) Output Location 34 CV 35: F1 Output Location 35 CV 36: F2 Output Location 36 CV 37: F3 Output Location 37 CV 38: F4 Output Location 38 CV 39: F5 Output Location 39 CV 40: F6 Output Location 40 CV 41: F7 Output Location 41 CV 42: F8 Output Location 42 CV 43: F9 Output Location 43 CV 44: F10 Output Location 44 CV 45: F11 Output Location 45 CV 46: F12 Output Location 46 Lighting Effect CVs 47 CVs 49-54: Hyperlight Effect Select 47 CV 57: Forward Direction Enable 51 CV 58: Reverse Direction Enable 52 CV 59: Hyperlight Flash Rate 53 CV 60: Grade-Crossing Hold Time 54 CV 61: Brightness Register 1 55 CV 62: Brightness Register 2 56 CV 63: Dimmer Level 57 CV 64: Master Brightness 58
4 Speed Table CVs 59 CV 66: Forward Motor Trim 59 CVs 67-94: Custom Speed Table 60 CV 95: Reverse Motor Trim 61 User Information CVs 62 CV 105: User Identifier 1 62 CV 106: User Identifier 2 63 Sound Control CVs 64 CV 113: Quiet Mode Time-Out Period 64 CV 114: Engine Exhaust Control 65 CV 117: Independent Brake Rate 66 CV 118: Train Brake Rate67 CV 119: Max Engine Recovery Speed68 CV 120: Airhorn Select 69 CV 121: Alternate Airhorn Select 70 CV 122: Bell Select71 CV 124: Air Compressor Select 72 CV 126: Coupler Select 73 CV 128: Master Volume 74 CVs : Primary Mixer Volume Levels75 CVs : Reverb Mixer 77 CV 193: Auto-Bell On Set Point 79 CV 194: Auto-Bell On Time 80 CV 195: Coach Door Count 81 CV 196: Brake Sensitivity 82 CV 197: Analog Mode Auto-Sound Enable 83 CV 198: DCC Mode Auto-Sound Enable 84 CV 200: Poppet Valve Release Rate 85 CVs : Motorman Omura Probability CVs 86 Advanced Motor Control CVs 87 CV 209: PID Kp Parameter 87 CV 210: PID Ki Parameter 88 CV 211: Low-Speed Compensation 89 CV 212: BEMF Feedback Intensity 90 CV 213: BEMF Sample Period 91 CV 214: BEMF Sample Aperture Time 92 CV 215: BEMF Reference Voltage 93 CV 216: Motor Speed Step Deadband 94 CV 217: Motor Control Register 95 CV 218: Analog Mode Motor Start Voltage 96 CV 220: Constant Brake Distance 97 Audio Control CVs 98 CV 224: High-Pass Filter Cutoff Frequency 98 CV 225: Equalizer Control Register 99 CVs : Cut/Boost Controls 100 CV 233: Reverb Control Register 101 CV 234: Reverb Output Level 102 CV 235: Reverb Delay Time 103 CV 236: Reverb Feedback Gain Level 104 Analog Function Enable CVs 105 CV 241: Analog Mode Function Enable CV 242: Analog Mode Function Enable 4 106
5 CV 243: Analog Mode Function Enable Consist Function Enable CVs 108 CV 245: Consist Function Enable CV 246: Consist Function Enable CV 247: Consist Function Enable Indexed CV Page CVs : Extended Function Mapping CVs 111 CVs : Effect Map Registers 113 CVs : Effect Auxiliary Map Registers 115 Indexed CV Page CVs : Alternate Mixer Volume Levels 116 CVs : DDE Control CVs 118 CV 2503: DDE Load Offset 118 CV 2504: DDE Load Slope 119 CV 2507: DDE Traction Motor Low Volume Limit 120 CV 2508: DDE Traction Motor High Volume Limit 121 CV 2509: DDE Attack Time Constant 122 CV 2510: DDE Release Time Constant 123 CV 2511: DDE Throttle Sensitivity 124 CV 2512: DDE Load Sensitivity 125 Indexed CV Page CVs : Clickety-Clack Effect CVs 126 CV 3257: Clickety-Clack Configuration 126 CV 3258: Clickety-Clack Sound Scalar 127
6 Primary CVs Primary CVs CV 1: Primary Address CV 1 is used to set the decoder s primary address from 1 to A6 A5 A4 A3 A2 A1 A0 A0-A6: Primary Address 0: Reserved Additional Information Entering values from 1 to 127 into CV 1 will set the primary address while in Service Mode The decoder will ignore commands that attempt to program this CV with values outside the range of 1 to 127 The decoder will process all valid instruction packets addressed with the value contained in CV 1 when bit 5 of CV 29 (Configuration Data 1) is set to 0 Entering a new value into CV 1 will: Set the value of CV 19 (Consist Address) to 0 Clear the Extended Address Mode Enable bit in CV 29 (bit 5) Bit 5 of CV 29 must be set to 1 in order for the value of CV 1 to be changed in Operations Mode Setting bit 5 of CV 29 back to 0 will then allow the decoder to recognize the new primary address Default Value: 3 Related CVs: CV (Extended Address) CV 19 (Consist Address) CV 29 (Configuration Data 1) Tsunami2 Electric Technical Reference 6
7 Primary CVs CV 2: Vstart CV 2 is used to set the voltage level applied to the motor at speed-step 1 D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Motor Start Voltage Additional Information The motor start voltage is calculated as a fraction of the available supply voltage Entering a value from 0 to 255 into CV 2 will adjust the starting voltage level Starting voltage is calculated as: Starting Voltage = Supply Voltage CV When CV 2 is set to a non-zero value, the decoder will offset all points of the speed table as speed increases CV 2 is used in conjunction with CV 5 (Vhigh) and CV 6 (Vmid) to configure the 3-point speed table The 3-point speed table is active when bit 4 (STE) of CV 29 is set to 0 and CVs 2, 5, and 6 are set to non-zero values Default Value: 0 Related CVs: CV 5 (Vhigh) CV 6 (Vmid) CV 29 (Configuration Data 1) Tsunami2 Electric Technical Reference 7
8 Primary CVs CV 3: Baseline Acceleration Rate CV 3 is used to set the decoder s acceleration rate D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Acceleration Rate Additional Information Entering a value from 0 to 255 into CV 3 will adjust the acceleration rate Acceleration is calculated as: Seconds/Speed Step = CV Number of Speed Steps When the value of CV 3 is 0, acceleration will respond instantly to increases in the throttle setting When the value of CV 3 is 255, the decoder will accelerate from a stop to full speed in approximately 38 minutes Setting CV 3 to a non-zero value in 14 or 28 speed-step mode will create a smoother acceleration response; the decoder is designed to interpolate between speed steps during acceleration when CV 3 is set to a non-zero value to eliminate erratic transitions Default Value: 0 Related CVs: CV 4 (Baseline Deceleration Rate) CV 23 (Consist Acceleration Rate) CV 24 (Consist Deceleration Rate) Tsunami2 Electric Technical Reference 8
9 Primary CVs CV 4: Baseline Deceleration Rate CV 4 is used to set the decoder s deceleration rate D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Deceleration Rate Additional Information Entering a value from 0 to 255 into CV 4 will adjust the deceleration rate Deceleration is calculated as: Seconds/Speed Step = CV Number of Speed Steps When the value of CV 4 is 0, deceleration will respond instantly to decreases in the throttle setting When the value of CV 4 is 255, the decoder will decelerate from full speed to a stop in approximately 38 minutes Setting CV 4 to a non-zero value in 14 or 28 speed-step mode will create a smoother deceleration response; the decoder is designed to interpolate between speed steps during deceleration when CV 4 is set to a non-zero value to eliminate erratic transitions Default Value: 0 Related CVs: CV 3 (Baseline Acceleration Rate) CV 23 (Consist Acceleration Rate) CV 24 (Consist Deceleration Rate) CV 117 (Independent Brake Rate) Tsunami2 Electric Technical Reference 9
10 Primary CVs CV 5: Vhigh CV 5 is used to set the voltage level applied to the motor at maximum speed and is active when the 3-point speed table is enabled D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Maximum Voltage Value Additional Information Maximum voltage is calculated as a fraction of the available supply voltage Entering a value from 0 to 255 into CV 5 will adjust the maximum speed voltage level Maximum voltage is calculated as: Maximum Voltage = Supply Voltage CV Values of 0 and 1 will disable the Vhigh speed table setting A value of 255 will set the Vhigh speed table setting to the maximum available voltage (100%) CV 5 is used in conjunction with CV 2 (Vstart) and CV 6 (Vmid) to configure the 3-point speed table The 3-point speed table is active when bit 4 (STE) of CV 29 is set to 0 and CVs 2, 5, and 6 are set to non-zero values Default Value: 0 Related CVs: CV 2 (Vstart) CV 6 (Vmid) CV 29 (Configuration Data 1) Tsunami2 Electric Technical Reference 10
11 Primary CVs CV 6: Vmid CV 6 is used to set the voltage level applied to the motor at the middle speed step and is active when the 3-point speed table is enabled D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Midpoint Voltage Value Additional Information Midpoint voltage is calculated as a fraction of the available supply voltage Entering a value from 0 to 255 into CV 6 will adjust the mid-speed voltage level Midpoint voltage is calculated as: Midpoint Voltage = Supply Voltage CV Values of 0 and 1 will disable the Vmid speed table setting A value of 255 will set the Vmid speed table setting to the maximum available voltage (100%) CV 6 is used in conjunction with CV 2 (Vstart) and CV 5 (Vhigh) to configure the 3-point speed table The 3-point speed table is active when bit 4 (STE) of CV 29 is set to 0 and CVs 2, 5, and 6 are set to non-zero values Default Value: 0 Related CVs: CV 2 (Vstart) CV 5 (Vhigh) CV 29 (Configuration Data 1) Tsunami2 Electric Technical Reference 11
12 Primary CVs CV 7: Manufacturer Version (Read-Only) CV 7 contains the 8-bit software version identifier CV 7 is read-only and cannot be modified D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Version Code 71 = Tsunami2 software version identifier Tsunami2 Electric Technical Reference 12
13 Primary CVs CV 8: Manufacturer ID CV 8 is used to reset CV settings to factory defaults and contains the NMRA-issued Manufacturer ID Code (141) assigned to SoundTraxx/Throttle Up! Entering a value from 8 to 13 into CV 8 will reset the CVs defined below Bits 0-7: CV Reset 8 = Full CV reset 9 = Reset CVs = Reset CVs = Reset CVs = Reset CVs = Reset CVs Manufacturer ID Code: 141 Tsunami2 Electric Technical Reference 13
14 Primary CVs CV 10: EMF Feedback Cutout CV 10 is used to gradually reduce back-emf control as locomotive speed increases D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: EMF Feedback Cutout Additional Information The BEMF intensity is defined as the amount of the BEMF signal that is fed back to the motor controller to stabilize the speed of the motor Reducing the intensity does not regulate the speed of the motor as effectively, but helps consisted locomotives from entering a push/pull scenario where one locomotive is doing all the work Per the equation below, this CV sets the speed step at which the intensity reaches zero When CV 10 is set to 0, only the value in CV 212 is used BEMF Intensity = CV 212 x (1 (speed step CV 10)) 255 Default Value: 0 Related CVs: CV 212 (BEMF Feedback Intensity) CV 213 (BEMF Sample Period) CV 214 (BEMF Sample Aperture Time) CV 215 (BEMF Reference Voltage) Tsunami2 Electric Technical Reference 14
15 Primary CVs CV 11: Packet Time-Out Value CV 11 is used to set duration in seconds that occurs from the time the decoder receives a valid packet to the time speed-related sound effects and motor processes are deactivated It can also be used to set the amount of time a CurrentKeeper equipped model is allowed to continue to operate after the decoder experiences a loss of power and DCC packets D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Packet Time-Out Value Additional Information Entering a value from 0 to 255 into CV 11 will set the packet time-out period The timeout period is calculated in seconds as follows: Time-Out Period = CV A value of 0 disables the time-out period A value of 255 sets the time-out period to approximately 1 minute The decoder maintains an internal timer that resets each time the decoder receives a valid packet In the event no valid packets are received during the time-out period, the decoder will deactivate motor processes and the locomotive will decelerate according to the value of CV 4 (Baseline Deceleration Rate) or CV 24 (Consist Deceleration Rate) Default Value: 0 Tsunami2 Electric Technical Reference 15
16 Primary CVs CV 12: Alternate Power Source CV 12 is used to allow the decoder to operate using an analog power supply when a DCC signal is not available Bit 3 (APS) of CV 29 (Configuration Data 1) must be set to 1 in order for an alternate power source to be used D0 D0: Alternate Power Source 0 = No alternate power source 1 = Analog power supply 0: Reserved Default Value: 1 Related CVs: CV 29 (Configuration Data 1) Tsunami2 Electric Technical Reference 16
17 Primary CVs CV 13: Analog Mode Function Enable 1 CV 13 is used to enable F1-F8 function assignments for analog mode operation Refer to CVs (Effect Map Registers) and/or CVs (Function Status CVs) for information regarding function mapping F8 F7 F6 F5 F4 F3 F2 F1 F1-F8: Analog Mode Function Enable 0 = Function disabled for analog operation 1 = Function enabled for analog operation Additional Information Setting bits 0-7 to 1 will enable the F1-F8 functions active in CVs and/or CVs for analog mode operation Default Value: 0 Related CVs: CV 14 (Analog Mode Function Enable 2) CV (Function Status CVs) CV (Analog Mode Function Enable 3-5) CV (Extended Function Mapping CVs) Tsunami2 Electric Technical Reference 17
18 Primary CVs CV 14: Analog Mode Function Enable 2 CV 14 is used to enable F0(f), F0(r), and F9-F12 function assignments for analog mode operation Refer to CVs (Effect Map Registers) and/or CVs (Function Status CVs) for information regarding function mapping 0 0 F12 F11 F10 F9 F0(r) F0(f) F0(f)-F0(r): Analog Mode F0 Enable 0 = Function disabled for analog operation 1 = Function enabled for analog operation F9-F12: Analog Mode Function Enable 0 = Function disabled for analog operation 1 = Function enabled for analog operation 0: Reserved Additional Information Setting bits 0-7 to 1 will enable the F0(f), F0(r), F9-F12 functions active in CVs and/or CVs for analog mode operation Default Value: 3 Related CVs: CV 13 (Analog Mode Function Enable 1) CV (Function Status CVs) CV (Analog Mode Function Enable 3-5) CV (Extended Function Mapping CVs) Tsunami2 Electric Technical Reference 18
19 Primary CVs CV 15: CV Unlock Code CV 15 is used for unlocking access to the decoder s CVs D2 D1 D0 D0-D2: CV Unlock Code 0: Reserved Additional Information Entering a value from 0 to 7 into CV 15 determines the decoder s lock status CV 15 can be accessed regardless of the decoder s lock status Locked State: If the value of CV 15 is not equal to the value of CV 16 (CV Lock ID), all CVs are locked Read and write operations will be ignored Unlocked State: The decoder s CVs can be accessed only when the value of CV 15 is equal to the value of CV 16 Note: Bit 0 (CV Lock Enable) of CV 30 (Error Information) must be set to 1 in order for the lock feature in CVs 15 and 16 to be used Default Value: 0 Related CVs: CV 16 (CV Lock ID) CV 30 (Error Information) Tsunami2 Electric Technical Reference 19
20 Primary CVs CV 16: CV Lock ID CV 16 is used in conjunction with CV 15 (CV Unlock Code) to determine the decoder s lock status CV 16 determines the lock code used to lock the decoder s CVs ID2 ID1 ID0 ID0-ID2: CV Lock Code 0: Reserved Additional Information Entering a value from 0 to 7 into CV 16 determines the decoder s lock status CV 16 can be accessed regardless of the decoder s lock status Locked State: If the value of CV 16 is not equal to the value of CV 15 (CV Unlock Code), all CVs are locked and all read and write operations will be ignored Unlocked State: The decoder s CVs will only be accessible when the value of CV 15 is equal to the value of CV 16 Note: Bit 0 (CV Lock Enable) of CV 30 (Error Information) must be set to 1 in order for the lock feature in CVs 15 and 16 to be used Default Value: 0 Related CVs: CV 15 (CV Unlock Code) CV 30 (Error Information) Tsunami2 Electric Technical Reference 20
21 Primary CVs CVs 17-18: Extended Address CVs 17 and 18 contain the decoder s 14-bit extended address and are merged as a paired CV CV 17: Extended Address MSB A15 A14 A13 A12 A11 A10 A9 A8 CV 18: Extended Address LSB A7 A6 A5 A4 A3 A2 A1 A0 A0-A15: Extended Address Value Additional Information Most command stations recognize from addresses Bit 5 of CV 29 (Configuration Data 1) must be set to 1 for the decoder to recognize commands sent to the extended address The decoder will ignore commands sent to the primary address when bit 5 of CV 29 is set to 1 Setting bit 5 of CV 29 to 0 will enable the primary address CV 17 contains the most significant bits of the two-byte address and can be set to values from 192 to 231 (0xC0-0xE7) CV 18 contains the least significant bits of the two-byte address and can be set to values from 0 to 255 CV 17 must be set before CV 18 The decoder will ignore attempts to adjust the values of CVs 17 and 18 out-of-order CV 17 and CV 18 can be modified in Service Mode at any time, but cannot be modified in Operations Mode unless bit 5 of CV 29 is set to 0 (ie, CV 1, Primary Address is enabled) Default Value: CV 17 = 192 CV 18 = 3 (Address 0003) Related CVs: CV 1 (Primary Address CV 19 (Consist Address) CV 29 (Configuration Data 1) Tsunami2 Electric Technical Reference 21
22 Primary CVs CV 19: Consist Address CV 19 is used to set the address and direction for advanced consist operation CDIR A6 A5 A4 A3 A2 A1 A0 A0-A6: Consist Address Value CDIR: Consist Direction 0 = Normal direction 1 = Inverted direction Additional Information Bits 0-6 (A0-A6) are used to assign the consist address from 1 to 127 Setting bit 7 (CDIR) to 1 will invert consist direction Entering a value from 1 to 127 will set the consist address from 1 to 127 for the normal direction Entering a value from 129 to 255 will set the consist address from 1 to 127 for the inverted direction Setting CV 19 to 0 or 128 will disable the consist address When CV 19 is set to a non-zero value, the decoder will ignore throttle commands sent to the decoder s primary or extended address The decoder will process valid commands sent to the consist address with the following exceptions: Long-form CV access instructions will be ignored The direction of a speed/direction command or an advanced operation command will be inverted when bit 7 (CDIR) is set to 1 Default Value: 0 Related CVs: CV 1 (Primary Address) CVs (Extended Address) CVs (Consist Function Enable 1-2) CV 23 (Consist Acceleration Rate) CV 24 (Consist Deceleration Rate) CVs (Consist Function Enable 3-5) Tsunami2 Electric Technical Reference 22
23 Primary CVs CV 21: Consist Function Enable 1 CV 21 is used to enable F1-F8 function assignments for advanced consist operation Refer to CVs (Effect Map Registers) and/or CVs (Function Status CVs) for more information regarding function mapping F8 F7 F6 F5 F4 F3 F2 F1 F1-F8: Consist Function Enable 0 = Function disabled for consist operation 1 = Function enabled for consist operation Additional Information CV 21 is commonly used to differentiate various engines and cars of the same consist Setting bits 0-7 to 1 will enable the F1-F8 functions active in CVs and/or CVs for advanced consist operation Default Value: 0 Related CVs: CV 19 (Consist Function Enable 2) CVs (Function Status CVs) CVs (Consist Function Enable 3-5) CVs (Extended Function Mapping CVs) Tsunami2 Electric Technical Reference 23
24 Primary CVs CV 22: Consist Function Enable 2 CV 22 is used to enable F0(f), F0(r), and F9-F12 function assignments for advanced consist operation Refer to CVs (Effect Map Registers) and/or CVs (Function Status CVs) for more information regarding function mapping 0 0 F12 F11 F10 F9 F0(r) F0(f) F0(f)-F0(r): Consist F0 Enable 0 = Function disabled for consist operation 1 = Function enabled for consist operation F9-F12: Consist Function Enable 0 = Function disabled for consist operation 1 = Function enabled for consist operation 0: Reserved Additional information CV 22 is commonly used to differentiate various engines and cars of the same consist Setting bits 0-7 to 1 will enable the F0(f), F0(r), and F9-F12 functions active in CVs and/or CVs for advanced consist operation Default Value: 0 Related CVs: CV 19 (Consist Address) CV 21 (Consist Function Enable 1) CVs (Function Status CVs) CVs (Consist Function Enable 3-5) CVs (Extended Function Mapping CVs) Tsunami2 Electric Technical Reference 24
25 Primary CVs CV 23: Consist Acceleration Rate CV 23 is used to set the consist acceleration rate CV 19 must contain a valid consist address for the consist acceleration rate to be active SIGN D6 D5 D4 D3 D2 D1 D0 D0-D6: Consist Acceleration Offset SIGN: Sign 0 = Positive value 1 = Negative value Additional Information The value of CV 23 determines the consist acceleration rate in relation to CV 3 (Baseline Acceleration Rate) When the consist address is active, the consist acceleration rate is added to or subtracted from the decoder s baseline acceleration rate depending on the sign bit Entering a value from 1 to 127 into CV 23 will increase the consist acceleration rate from the baseline acceleration rate in CV 3 Entering values from 129 to 255 into CV 23 will decrease the consist acceleration rate from the baseline acceleration rate in CV 3 Values of 0 and 128 will disable the consist acceleration rate and the decoder will use the value in CV3 When bit 7 (SIGN) of CV 23 is set to 0, the value added to CV 3 will be positive, where if bit 7 is set to 1, the value added to CV 3 will be negative: Acceleration is calculated as: = = 0 1 = = = = -127 Seconds/Speed Step = (CV 3 + CV 23) 0896 Number of Speed Steps Default Value: 0 Related CVs: CV 3 (Baseline Acceleration Rate) CV 4 (Baseline Deceleration Rate) CV 19 (Consist Address) CV 24 (Consist Deceleration Rate) Tsunami2 Electric Technical Reference 25
26 Primary CVs CV 24: Consist Deceleration Rate CV 24 is used to set the consist deceleration rate CV 19 must contain a valid consist address for the consist deceleration rate to be active SIGN D6 D5 D4 D3 D2 D1 D0 D0-D6: Consist Deceleration Offset SIGN: Sign 0 = Positive value 1 = Negative value Additional Information The value of CV 24 determines the consist deceleration rate in relation to CV 4 (Baseline Deceleration Rate) When the consist address is active, the consist deceleration rate is added to or subtracted from the decoder s baseline deceleration rate depending on the sign bit Entering a value from 1 to 127 into CV 24 will increase the consist deceleration rate from the baseline deceleration rate in CV 4 Entering values from 129 to 255 into CV 24 will decrease the consist deceleration rate from the baseline deceleration rate in CV 4 Values of 0 and 128 will disable the consist deceleration rate and the decoder will use the value in CV3 When bit 7 (SIGN) of CV 24 is set to 0, the value added to CV 4 will be positive, where if bit 7 is set to 1, the value added to CV 4 will be negative: Deceleration is calculated as: = = 0 1 = = = = -127 Seconds/Speed Step = (CV 4 + CV 24) 0896 Number of Speed Steps Default Value: 0 Related CVs: CV 3 (Baseline Acceleration Rate) CV 4 (Baseline Deceleration Rate) CV 19 (Consist Address) CV 23 (Consist Acceleration Rate) Tsunami2 Electric Technical Reference 26
27 Primary CVs CV 25: Speed Table Enable CV 25 is used in conjunction with CV 29 (Configuration Data 1) to enable the linear or 28-point speed table MIDSPD D6 D5 D4 D3 D2 D1 D0 D0-D6: Table Identifier 0 = Disabled, Speed Curves not used 1 = Disabled, Speed Curves not used 2 = Linear Speed Curve 3 = Reserved 4 = Reserved 5 = Reserved 6 = Reserved 7 = Reserved 8 = Reserved 9 = Reserved 10 = Reserved 11 = Reserved 12 = Reserved 13 = Reserved 14 = Reserved 15 = Reserved 16 = User Defined Speed Table defined by CVs MIDSPD: Reserved Additional Information Speed tables are disabled by default and voltage is directly proportional to the speed step Default Value: 0 Related CVs: CV 2 (Vmid) CV 5 (Vhigh) CV 6 (Vmid) CV 29 (Configuration Data 1) CVs (Custom Speed Table) Tsunami2 Electric Technical Reference 27
28 Primary CVs CV 29: Configuration Data 1 CV 29 contains miscellaneous configuration bits 0 0 EAM STE 0 APS F0 DIR DIR: Direction 0 = Normal direction 1 = Inverted direction F0: F0 Location 0 = 14 speed-step mode enabled 1 = 28/128 speed-step mode enabled APS: Alternate Power Source Enable 0 = NMRA-digital only 1 = Alternate power source enabled (CV 12) STE: Speed Table Enable 0 = 3-point speed table enabled 1 = Linear/28-point speed table (CV 25) EAM: Extended Address Mode Enable 0 = Primary address enabled (CV 1) 1 = Extended address enabled (CVs 17-18) 0: Reserved Note: Command stations that do not support the extended address can interfere with normal operation if bit 5 of CV 29 is programmed inadvertently In this situation, connect the decoder to a programming track and set bit 5 of CV 29 to 0 Default Value: 2 Related CVs: CV 1 (Primary Address) CV 2 (Vstart) CV 5 (Vhigh) CV 6 (Vmid) CV 12 (Alternate Power Source) CVs (Extended Address) CV 25 (Speed Table Enable) CVs (Custom Speed Table) Tsunami2 Electric Technical Reference 28
29 Primary CVs CV 30: Error Information CV 30 is used to allow the decoder s CVs to be locked and unlocked with CV 15 (CV Unlock Code) and CV 16 (CV Lock ID) LCK LCK: CV Lock/Unlock Enable 0 = CV lock/unlock feature disabled 1 = CV lock/unlock feature enabled (CVs 15-16) 0: Reserved Default Value: 0 Related CVs: CV 15 (CV Unlock Code) CV 16 (CV Lock ID) Tsunami2 Electric Technical Reference 29
30 Primary CVs CV 31: CV Index 1 CV 31 and CV 32 (CV Index 2) contain the indexed address used for accessing CVs exceeding CV 256 CV 31 contains the most significant bits of the two-byte address and enables indexed CV operation, as determined by CV 32 Note: Modifying the default value of CV 31 will disable indexed CV operation; CV 31 should never be programmed from its default value D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: CV Index MSB 16 = Indexed address Default Value: 16 Related CVs: CV 32 (CV Index 2) Tsunami2 Electric Technical Reference 30
31 Primary CVs CV 32: CV Index 2 CV 32 provides access to CVs exceeding CV 256 and is used to select the active indexed CV page Tsunami2 supports three indexed CV pages: 1 CVs : Indexed CV Page 1 2 CVs : Indexed CV Page 2 3 CVs : Indexed CV Page 3 The value of CV 32 indicates the active indexed CV page CVs allow access to indexed CVs when an indexed CV page is selected in CV 32 D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: CV Index LSB 1 = Indexed CV Page 1 2 = Indexed CV Page 2 3 = Indexed CV Page 3 Additional Information Entering a value of 1 into CV 32 will select Indexed CV Page 1 as the active indexed CV page Indexed CV Page 1 contains Flex-Map function mapping CVs: CVs : Effect Map Registers CVs : Effect Auxiliary Map Registers Entering a value of 2 into CV 32 will select Indexed CV Page 2 as the active indexed CV page Indexed CV Page 2 contains alternate mixer channel volume control CVs: CVs : Alternate Mixer Volume Levels CVs : DDE Control CVs Entering a value of 3 into CV 32 will select Indexed CV Page 3 as the active indexed CV page Indexed CV Page 3 contains clickety-clack effect CVs: CV : Clickety-Clack Effect CVs Entering a value of 0 or values from 4 to 255 into CV 32 will disable access to CVs exceeding CV 256 If your system does not allow access to CVs exceeding CV 256, contact the manufacturer for more information Default Value: 1 Related CVs: CV 31 (CV Index 1) CVs (Extended Function Mapping CVs) CVs (Alternate Mixer Volume Levels) CVs (DDE Control CVs) CVs (Clickety-Clack Effect CVs) Tsunami2 Electric Technical Reference 31
32 Primary CVs CVs 33-46: Function Status CVs Function Status CVs can be used to map a limited range of effects to functions F0-F12 and are included to remain consistent with NMRA Standards for DCC Configuration Variables (S-922, p7) Note: CVs are set to values of 0 by default, are a secondary method of function mapping for those wishing to use the Legacy Function Mapping associated with the prior generation of Tsunami products, and are not used to determine Tsunami2 s default function assignments CVs (Flex-Map Function Mapping CVs) provide function assignments for 28 function keys and offer comprehensive function mapping support for all of Tsunami2 s effects in an uncomplicated and versatile format However, mapping an effect to a function key (F0(f), F0(r), or F1-F12) using CVs will override the corresponding function assignment mapped within CVs Note: The use of Legacy Function Mapping and Flex-Map Function Mapping together may produce undesirable results and is not recommended Effects mapped to CV 33 (F0(f) Output Location) can be activated in the forward direction only and effects mapped to CV 34 (F0(r) Output Location) can be activated in the reverse direction only This output is bidirectional only when same effect has been mapped to both CVs The function mapping table provided below indicates the values used for mapping functions to effects All provided effects cannot be mapped to all F0-F12 functions keys Function Output Map Function Key CV HL Output BL Output Airhorn Bell FX3 Output FX4 Output Pneum Doors Short Airhorn Pantograph General Service Dimmer Mute Stop Req Bell Ind/Train Brake Coupler F0(f) F0(r) F F F F F F F F F F F F Tsunami2 Electric Technical Reference 32
33 Primary CVs CV 33: F0(f) Output Location CV 33 is used to map a given effect to the F0(f) function key The enabled effect will be activated when the F0(f) function is turned on Disabled effects will have no relation to the F0(f) function key SAH PD FX4 FX3 BEL AH BL HL HL: Headlight Output 0 = Headlight disabled 1 = Headlight enabled BL: Backup Light Output 0 = Backup light disabled 1 = Backup light enabled AH: Airhorn 0 = Airhorn disabled 1 = Airhorn enabled BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled PD: Pneumatic Doors 0 = Pneumatic doors disabled 1 = Pneumatic doors enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled Default Value: 0 Tsunami2 Electric Technical Reference 33
34 Primary CVs CV 34: F0(r) Output Location CV 34 is used to map a given effect to the F0(r) function key The enabled effect will be activated when the F0(r) function is turned on Disabled effects will have no relation to the F0(r) function key SAH PD FX4 FX3 BEL AH BL HL HL: Headlight Output 0 = Headlight disabled 1 = Headlight enabled BL: Backup Light Output 0 = Backup light disabled 1 = Backup light enabled AH: Airhorn 0 = Airhorn disabled 1 = Airhorn enabled BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled PD: Pneumatic Doors 0 = Pneumatic doors disabled 1 = Pneumatic doors enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled Default Value: 0 Tsunami2 Electric Technical Reference 34
35 Primary CVs CV 35: F1 Output Location CV 35 is used to map a given effect to the F1 function key The enabled effect will be activated when the F1 function is turned on Disabled effects will have no relation to the F1 function key SAH PD FX4 FX3 BEL AH BL HL HL: Headlight Output 0 = Headlight disabled 1 = Headlight enabled BL: Backup Light Output 0 = Backup light disabled 1 = Backup light enabled AH: Airhorn 0 = Airhorn disabled 1 = Airhorn enabled BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled PD: Pneumatic Doors 0 = Pneumatic doors disabled 1 = Pneumatic doors enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled Default Value: 0 Tsunami2 Electric Technical Reference 35
36 Primary CVs CV 36: F2 Output Location CV 36 is used to map a given effect to the F2 function key The enabled effect will be activated when the F2 function is turned on Disabled effects will have no relation to the F2 function key SAH PD FX4 FX3 BEL AH BL HL HL: Headlight Output 0 = Headlight disabled 1 = Headlight enabled BL: Backup Light Output 0 = Backup light disabled 1 = Backup light enabled AH: Airhorn 0 = Airhorn disabled 1 = Airhorn enabled BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled PD: Pneumatic Doors 0 = Pneumatic doors disabled 1 = Pneumatic doors enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled Default Value: 0 Tsunami2 Electric Technical Reference 36
37 Primary CVs CV 37: F3 Output Location CV 37 is used to map a given effect to the F3 function key The enabled effect will be activated when the F3 function is turned on Disabled effects will have no relation to the F3 function key DIM GS PAN SAH PD FX4 FX3 BEL BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled PD: Pneumatic Doors 0 = Pneumatic doors disabled 1 = Pneumatic doors enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled PAN: Pantograph 0 = Pantograph disabled 1 = Pantograph doors enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled GS: General Service 0 = General Service disabled 1 = General Service enabled Default Value: 0 Tsunami2 Electric Technical Reference 37
38 Primary CVs CV 38: F4 Output Location CV 38 is used to map a given effect to the F4 function key The enabled effect will be activated when the F4 function is turned on Disabled effects will have no relation to the F4 function key DIM GS PAN SAH PD FX4 FX3 BEL BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled PD: Pneumatic Doors 0 = Pneumatic doors disabled 1 = Pneumatic doors enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled PAN: Pantograph 0 = Pantograph disabled 1 = Pantograph doors enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled GS: General Service 0 = General Service disabled 1 = General Service enabled Default Value: 0 Tsunami2 Electric Technical Reference 38
39 Primary CVs CV 39: F5 Output Location CV 39 is used to map a given effect to the F5 function key The enabled effect will be activated when the F5 function is turned on Disabled effects will have no relation to the F5 function key DIM GS PAN SAH PD FX4 FX3 BEL BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled PD: Pneumatic Doors 0 = Pneumatic doors disabled 1 = Pneumatic doors enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled PAN: Pantograph 0 = Pantograph disabled 1 = Pantograph doors enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled GS: General Service 0 = General Service disabled 1 = General Service enabled Default Value: 0 Tsunami2 Electric Technical Reference 39
40 Primary CVs CV 40: F6 Output Location CV 40 is used to map a given effect to the F6 function key The enabled effect will be activated when the F6 function is turned on Disabled effects will have no relation to the F6 function key DIM GS PAN SAH PD FX4 FX3 BEL BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled PD: Pneumatic Doors 0 = Pneumatic doors disabled 1 = Pneumatic doors enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled PAN: Pantograph 0 = Pantograph disabled 1 = Pantograph doors enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled GS: General Service 0 = General Service disabled 1 = General Service enabled Default Value: 0 Tsunami2 Electric Technical Reference 40
41 Primary CVs CV 41: F7 Output Location CV 41 is used to map a given effect to the F7 function key The enabled effect will be activated when the F7 function is turned on Disabled effects will have no relation to the F7 function key BRK SRB MUT DIM GS PAN SAH PD PD: Pneumatic Doors 0 = Pneumatic doors disabled 1 = Pneumatic doors enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled PAN: Pantograph 0 = Pantograph disabled 1 = Pantograph enabled GS: General Service 0 = General Service disabled 1 = General Service enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled MUT: Mute 0 = Mute disabled 1 = Mute enabled SRB: Stop Request Bell 0 = Stop request bell disabled 1 = Stop request bell enabled BRK: Independent/Train Brake 0 = Independent/train brake disabled 1 = Independent/train brake enabled Default Value: 0 Tsunami2 Electric Technical Reference 41
42 Primary CVs CV 42: F8 Output Location CV 42 is used to map a given effect to the F8 function key The enabled effect will be activated when the F8 function is turned on Disabled effects will have no relation to the F8 function key BRK SRB MUT DIM GS PAN SAH PD PD: Pneumatic Doors 0 = Pneumatic doors disabled 1 = Pneumatic doors enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled PAN: Pantograph 0 = Pantograph disabled 1 = Pantograph enabled GS: General Service 0 = General Service disabled 1 = General Service enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled MUT: Mute 0 = Mute disabled 1 = Mute enabled SRB: Stop Request Bell 0 = Stop request bell disabled 1 = Stop request bell enabled BRK: Independent/Train Brake 0 = Independent/train brake disabled 1 = Independent/train brake enabled Default Value: 0 Tsunami2 Electric Technical Reference 42
43 Primary CVs CV 43: F9 Output Location CV 43 is used to map a given effect to the F9 function key The enabled effect will be activated when the F9 function is turned on Disabled effects will have no relation to the F9 function key BRK SRB MUT DIM GS PAN SAH PD PD: Pneumatic Doors 0 = Pneumatic doors disabled 1 = Pneumatic doors enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled PAN: Pantograph 0 = Pantograph disabled 1 = Pantograph enabled GS: General Service 0 = General Service disabled 1 = General Service enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled MUT: Mute 0 = Mute disabled 1 = Mute enabled SRB: Stop Request Bell 0 = Stop request bell disabled 1 = Stop request bell enabled BRK: Independent/Train Brake 0 = Independent/train brake disabled 1 = Independent/train brake enabled Default Value: 0 Tsunami2 Electric Technical Reference 43
44 Primary CVs CV 44: F10 Output Location CV 44 is used to map a given effect to the F10 function key The enabled effect will be activated when the F10 function is turned on Disabled effects will have no relation to the F10 function key CPL BRK SRB MUT DIM GS PAN SAH SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled PAN: Pantograph 0 = Pantograph disabled 1 = Pantograph doors enabled GS: General Service 0 = General Service disabled 1 = General Service enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled MUT: Mute 0 = Mute disabled 1 = Mute enabled SRB: Stop Request Bell 0 = Stop request bell disabled 1 = Stop request bell enabled BRK: Independent/Train Brake 0 = Independent/train brake disabled 1 = Independent/train brake enabled CPL: Coupler 0 = Coupler disabled 1 = Coupler enabled Default Value: 0 Tsunami2 Electric Technical Reference 44
45 Primary CVs CV 45: F11 Output Location CV 45 is used to map a given effect to the F11 function key The enabled effect will be activated when the F11 function is turned on Disabled effects will have no relation to the F11 function key CPL BRK SRB MUT DIM GS PAN SAH SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled PAN: Pantograph 0 = Pantograph disabled 1 = Pantograph doors enabled GS: General Service 0 = General Service disabled 1 = General Service enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled MUT: Mute 0 = Mute disabled 1 = Mute enabled SRB: Stop Request Bell 0 = Stop request bell disabled 1 = Stop request bell enabled BRK: Independent/Train Brake 0 = Independent/train brake disabled 1 = Independent/train brake enabled CPL: Coupler 0 = Coupler disabled 1 = Coupler enabled Default Value: 0 Tsunami2 Electric Technical Reference 45
46 Primary CVs CV 46: F12 Output Location CV 46 is used to map a given effect to the F12 function key The enabled effect will be activated when the F12 function is turned on Disabled effects will have no relation to the F12 function key CPL BRK SRB MUT DIM GS PAN SAH SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled PAN: Pantograph 0 = Pantograph disabled 1 = Pantograph doors enabled GS: General Service 0 = General Service disabled 1 = General Service enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled MUT: Mute 0 = Mute disabled 1 = Mute enabled SRB: Stop Request Bell 0 = Stop request bell disabled 1 = Stop request bell enabled BRK: Independent/Train Brake 0 = Independent/train brake disabled 1 = Independent/train brake enabled CPL: Coupler 0 = Coupler disabled 1 = Coupler enabled 0: Reserved Default Value: 0 Tsunami2 Electric Technical Reference 46
47 Lighting Effect CVs Lighting Effect CVs CVs 49-54: Hyperlight Effect Select CVs are used to configure up to six lighting outputs with Hyperlight lighting effects and other lighting features Bit definitions for CVs are identical CV 49: Headlight Configuration (F0(f) by default) CV 50: Backup Light Configuration (F0(r) by default) CV 51: FX3 Configuration (F24 by default) CV 52: FX4 Configuration (F25 by default) CV 53: FX5 Configuration (F26 by default) ** CV 54: FX6 Configuration (F27 by default) ** ** Available on select formats LED XING PHSE EF4 EF3 EF2 EF1 EF0 EF0-EF4: Hyperlight Effect Select 0 = On/off output 1 = Dimmable on/off headlight 2 = Mars Light 3 = Pyle-National Gyralite 4 = Oscillating headlight 5 = Single-flash strobe 1 6 = Double-flash strobe 7 = Western-Cullen D312 Rotary Beacon 8 = Prime Stratolite 9 = Ditch light type I 10 = Ditch light type II 11 = Flashing rear-end device (FRED) 12 = Engine exhaust flicker 13 = Firebox flicker 14 = Smart firebox flicker 15 = Dyno-light 16 = Auto-dim forward 17 = Auto-dim reverse 18 = Brake light 19 = On/off brightness 1 20 = On/off brightness 2 21 = Emergency Gyralite 22 = Electrical arcing 23 = Ash pan flicker 24 = Reserved 25 = Single-flash strobe 2 Tsunami2 Electric Technical Reference 47
48 Lighting Effect CVs PHSE: Phase Select 0 = Phase A 1 = Phase B XING: Grade-Crossing Logic Enable 0 = Grade-Crossing Logic disabled 1 = Grade-Crossing Logic enabled LED: LED Compensation Mode Enable 0 = Incandescent-compatible outputs enabled 1 = LED-compatible outputs enabled Additional Information On/Off Output The on/off lighting effect provides on/off control for the corresponding function Use this effect when the function output is being utilized to drive external electronics such as a low power relay to control a smoke generator or a servo motor Dimmable On/Off Headlight The output set to the dimmable headlight will be reduced to the brightness setting in CV 63 when you turn on the dimmer function (F7 by default) Mars Light The Mars light warning beacon follows the famous figure-eight sweep pattern and oscillates more rapidly than the Gyralite Pyle-National Gyralite The Pyle-National Gyralite is similar to the Mars Light, but oscillates in a circular or elliptical pattern Oscillating Headlight The dual-oscillating headlight generates two beams that follow each other in a tight, circular sweep pattern Single-Flash Strobes 1 and 2 The xenon single-flash strobe 1 effect flashes once during each flash rate timing cycle The xenon single-flash strobe 2 flashes once during each flash rate timing cycle, but at a slightly faster rate This effect allows you to mimic warning lights found on many Amtrak locomotives as well as remote control operated (or RCO ) locomotives Double-Flash Strobe The xenon double-flash strobe effect emits two rapid flashes of light during each flash rate timing cycle CV 59 is used to modify the flash rate timing cycle Western-Cullen D312 Rotary Beacon The Western-Cullen D312 Rotary Beacon effect follows a revolving reflector and bulb assembly flash-pattern Tsunami2 Electric Technical Reference 48
49 Lighting Effect CVs Prime Stratolite The Stratolite is made up of four individual lamps arranged in a circular pattern The Stratolite flashes in a clockwise direction in a mechanical stepped fashion, unlike the smooth motion of the rotary beacon Ditch Lights Type I and II Ditch lights type I and II flash together by default When Grade-Crossing Logic is enabled, ditch light I assumes a steady on state before and after the crossing hold timer countdown Conversely, ditch light II will remain off before and after the crossing hold timer countdown To configure alternating ditch lights, set one lighting output to ditch light I or II and enable Grade-Crossing Logic, and then set a second lighting output to the same ditch light and enable Grade-Crossing Logic and phase offset FRED (Flashing Rear End Device) The FRED effect is a flashing red taillight that indicates the rear of the train Dyno-Light In a diesel locomotive, the lights will fade on and fade off to simulate the heating and cooling of the bulb filaments Auto-Dim Forward and Reverse The auto-dim forward effect will automatically dim lighting outputs to the dimmer level in CV 63 when in the forward direction, and the auto-dim reverse effect will automatically dim lighting outputs to the dimmer level in CV 63 when in the reverse direction Brake Light The brake light effect is dimmed to the brightness setting in CV 63 when active The brake light brightness level will be automatically set to 100% when you turn on the independent or train brake function (F11 by default) On/Off Brightness 1 and 2 On/Off Brightness effects 1 and 2 allow you to independently adjust the level of up to 2 lighting outputs You can accurately recreate low brilliance lighting effects on your model such as class lights, lit number boards or marker lamps The on/off brightness 1 and 2 effects will set lighting outputs to the brightness levels of CVs 61 and 62, respectively Emergency Gyralite The emergency Gyralite follows the same oscillating sweep pattern as the Gyralite, and will automatically disable all active lighting effects Electrical Arcing The electrical arcing effect produces a simulated shower of sparks in time with the electrical arcing sound effect to simulate the pantograph breaking contact with the overhead wire This effect only works above speed step 10 in 128 speed step mode Phase Offset Add a value of 32 to the value of flashing Hyperlight effects to set the corresponding lighting output to Phase B from Phase A Flashing effects set to Phase B will flash opposite of flashing effects set to Phase A, ie, Phase A turns off when Phase B turns on, and Phase A turns on when Phase B turns off Tsunami2 Electric Technical Reference 49
50 Lighting Effect CVs Grade-Crossing Logic Grade-Crossing Logic allows you to set up lighting functions, the bell, and airhorn to automatically simulate encountering grade crossings Add a value of 64 to enable Grade-Crossing Logic Turning on the long airhorn function (F2 by default) or the gradecrossing signal function (F9 by default) will start the crossing hold timer countdown and allow lighting effects to assume a flashing state Shown in Table F, flashing Hyperlight effects will return to an on or off state after the countdown ends Practice activating Grade-Crossing Logic as your locomotive approaches a grade crossing You can adjust the crossing hold timer countdown from 0 to 15 seconds by entering a value from 0 to 15 into CV 60 (Grade-Crossing Hold Time) Refer to Table F located below for a list of Hyperlight effects commonly configured with Grade Crossing Logic (including alternating ditch lights) and corresponding CV values Table F Commonly Configured Hyperlight Effects CV Value Crossing Logic Crossing Logic Grade Crossing Effect Type Off On Logic Effect State Phase A Phase B Phase A Phase B Mars Light On Pyle-National Gyralite On Oscillating Headlight On Single-Flash Strobe Off Single-Flash Strobe Off Double-Flash Strobe Off D312 Rotary Beacon Off Prime Stratolite Off Ditch Light I On Ditch Light II Off FRED Off LED Compensation Mode The brightness of an incandescent bulb is determined by voltage, whereas an LED s brightness is determined by current LED Compensation Mode alters the method of sending current to the LED to balance the LED and incandescent brightness levels Add a value of 128 to enable LED Compensation Mode for the corresponding lighting output Note: Enabling LED Compensation Mode will not change the output voltage Resistors may still be necessary depending on the board format and drive voltage of the LED Default Value: CVs = 15 Tsunami2 Electric Technical Reference 50
Econami Digital Sound Decoder Diesel Technical Reference Software Release 1.6
Econami Digital Sound Decoder Diesel Technical Reference Software Release 16 Previous software versions included Rev E 11/14/17 Notice The information in this document is subject to change without notice
More informationEconami Digital Sound Decoder Steam Technical Reference Software Release 1.6
Econami Digital Sound Decoder Steam Technical Reference Software Release 16 Previous software versions included Rev H 11/14/17 Notice The information in this document is subject to change without notice
More informationTsunami2 Digital Sound Decoder Steam Technical Reference Software Release 1.2 **
Tsunami2 Digital Sound Decoder Steam Technical Reference Software Release 12 ** ** Previous software versions included Rev D 11/08/17 Notice The information in this document is subject to change without
More informationTsunami Digital Sound Decoder. Quick Start Guide for the Blackstone Models C-19
Tsunami Digital Sound Decoder Quick Start Guide for the Blackstone Models C-19 May 2011 Notice The information in this document is subject to change without notice. Neither Blackstone Models or SoundTraxx
More informationCopies of the NMRA DCC Standards and Recommended Practices may be obtained by contacting:
Scope This section of the manual is designed to provide the advanced user with additional insight into the operation and capabilities of the SoundTraxx Digital Sound Decoder. By necessity, it is somewhat
More informationNIMFT-B Decoder $ Plug and play decoder for Intermountain FT-B units
NIMFT-B Decoder Plug and play decoder for Intermountain FT-B units $29.95 This is an EPF (extended packet format) decoder supporting: Silent Running TM motor drive eliminates annoying motor hum or buzz
More informationPOWERHOUSE Digital Command Control
Technical Reference TM POWERHOUSE Digital Command Control SW9-SR Drop-In Decoder Dimensions:.95 x.83 x.2 inches 5 x 2 x 3. mm Version 3.2 $29.95 This decoder is designed for easy installation in Lifelike
More informationPOWER PRO. Digital Command Control. D14SRP Decoder. Decoder version 3.2 $29.95
Technical Reference for the TM POWER PRO Digital Command Control D4SRP Decoder Dimensions:.8 x.65 inches 27 x 6.5 mm Decoder version 3.2 $29.95 This decoder is designed specifically to fit decoders with
More informationN12SR Decoder. $29.95 Decoder version 3.3 Dimensions: 0.34 x 0.70 x.12 inches x 18 x 3.2 mm
N12SR Decoder $29.95 Decoder version 3.3 Dimensions: 0.34 x 0.70 x.12 inches - 8.6 x 18 x 3.2 mm This is an EPF (extended packet format) decoder supporting: Silent Running TM motor drive eliminates annoying
More informationPOWER PRO Digital Command Control
Technical Reference for the TM POWER PRO Digital Command Control D13SR Decoder Dimensions: 1.65 x 0.630 x.120 inches 42 x 16.5 x 3.2 mm Decoder version 3.2 $29.95 This is an EPF (extended packet format)
More informationPOWER PRO. Digital Command Control. DA-SR Decoder. Decoder version 3..2 $29.95
Technical Reference for the TM POWER PRO Digital Command Control DA-SR Decoder Dimensions: 2.85 x.66 x.2 inches 72 x 7 x 3.2 mm Decoder version 3..2 $29.95 Atlas GP38, GP, RS/2/3, C2/5, GP7, RSD/5/2, C3-7,
More informationWhen shipped from factory default operating mode is mobile(loco) decoder; "Loco address 3"
Light-it, Notes to self When shipped from factory default operating mode is mobile(loco) decoder; "Loco address 3" Factory rest set CV128 to value of 170; "sets decoder back to factory settings" Can be
More informationMulti-protocol decoder with Load Regulation for Locomotives with 21-way connector
Multi-protocol decoder with Load Regulation for Locomotives with 2-way connector Features Locomotive Decoder Multi-protocol decoder with load regulation for DCC and Motorola Suitable for DC and Bell armature
More informationCombi-Decoder SL51-4 for OO/HO
www.tran.at Combi-Decoder SL51-4 for OO/HO Translation to English and annotation by YouChoos (www.youchoos.co.uk) 3 rd edition, October 2011 Technical data and installation Track voltage DCC 7-24V Maximum
More informationMulti-protocol Decoder with load regulation for DC and Faulhaber Motors Features Description
Multi-protocol Decoder with load regulation for DC and Faulhaber Motors Features Regulated Multi-protocol decoder for DCC, Motorola Suitable for DC and Bell armature motors up to.7a Quiet motor running
More informationSRVODRV REV7 INSTALLATION NOTES
SRVODRV-8020 -REV7 INSTALLATION NOTES Thank you for purchasing the SRVODRV -8020 drive. The SRVODRV -8020 DC servo drive is warranted to be free of manufacturing defects for 1 year from the date of purchase.
More informationINDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual
INDEX A AC Drive Cover: 1 6 Dimensions: 2 4 External Parts and Labels: 1 6 Heat Sink Fins: 1 6 Input Mode Switch (Sink/Source): 1 6 Introduction to DuraPulse GS3 AC drive: 1 3 Keypad: 1 6 Model Number
More informationPololu TReX Jr Firmware Version 1.2: Configuration Parameter Documentation
Pololu TReX Jr Firmware Version 1.2: Configuration Parameter Documentation Quick Parameter List: 0x00: Device Number 0x01: Required Channels 0x02: Ignored Channels 0x03: Reversed Channels 0x04: Parabolic
More informationGS1 Parameter Summary Detailed Parameter Listings...4 9
CHAPTER AC DRIVE 4 PARAMETERS Contents of this Chapter... GS1 Parameter Summary...............................4 2 Detailed Parameter Listings..............................4 9 Motor Parameters.........................................4
More informationTEAM DIGITAL. Servette TM Single Servo Controller
12 7 Summary of Configuration Variables CV# Function/Default Value CV# Function/Default Value 1 Servo Address 1 43 reserved - 2 reserved - 44 Sec Input Control 26 3 Servo Move Range 15 45 reserved - 4
More information1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.
Fig. 1 Lock/ unlock 30 1000 Light 1 100 300 zone 1 Learn actual lux LED 600 2000 0,4 0,6 0,8 1,0 1,2 Time 1 Light 2 zone 2 1,4 1,6 Factor of lux zone 1 Pulse 2min 5min Time Time 2 10min 15min 30min 1 2
More informationCHAPTER AC DRIVE PARAMETERS. In This Chapter...
CHAPTER AC DRIVE 4 PARAMETERS In This Chapter... GS2 Parameter Summary....................4 2 Detailed Parameter Listings.................4 11 Motor Parameters........................4 11 Ramp Parameters.........................4
More informationTAM VALLEY DEPOT. Quad-LN User Manual. Gen2 Firmware v1.1
TAM VALLEY DEPOT Quad-LN User Manual Gen2 Firmware v1.1 N3IX Engineering 20 Aug 2013 Contents 1 Basics... 1 1.1 Overview... 1 1.2 Servos... 1 1.3 External Power Supply... 1 1.4 Onboard LED Indicators...
More informationINTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.
RYKO Manufacturing Company 116 N.W. 54th Ave. P.O.Box 38 Grimes, Iowa 5111 Phone (515) 986-37 www.ryko.com Fax (515) 986-3621 sales@ ryko.com INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+
More informationTEAM DIGITAL. SMC4 Servo & Motor Controller
16 CV# Function/Default Value CV# Function/Default Value 28 reserved - 73 Servo 3 Behavior 0 29 Decoder Configuration 0 74 Servo 4 Behavior 0 30 reserved - 75 Output Flash 0 31 Ops Mode Loco Address 1
More informationCV list expert s searching tool Version: October 2018
CV list expert s searching tool Version: October 2018 This CV list is an addition to the instruction manual for ZIMO driving decoders. The left column shows the chapters of the ZIMO instruction manual
More informationQuickBuilder PID Reference
QuickBuilder PID Reference Doc. No. 951-530031-006 2010 Control Technology Corp. 25 South Street Hopkinton, MA 01748 Phone: 508.435.9595 Fax: 508.435.2373 Thursday, March 18, 2010 2 QuickBuilder PID Reference
More informationRelease 0.3. Rolling Thunder Technical Reference Manual
Release 0.3 Rolling Thunder Technical Reference Manual INTRODUCTION Introduction Rolling Thunder consists of one transmitter in a Paragon 3 Rolling Thunder equipped locomotive and one Rolling Thunder receiver
More informationOperation Instruction Manual KAM-TC1000. Precision Temperature Controller
Kamweld Industries Inc. Operation Instruction Manual KAM-TC1000 Precision Temperature Controller Introduction Thank you for purchasing Kamweld's Percision temperature controller, KAM-TC1000. We sincerely
More informationCHAPTER 8 SUMMARY OF PARAMETER SETTINGS
CHAPTER 8 SUMMARY OF PARAMETER SETTINGS VFD-S Series!: The parameter can be set during operation, *: Twice the value for 460V class. Group 0 User Parameters Parameters Explanation s 0-00 Identity Code
More informationPush Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control
Installation Guide MMTM/PB Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control Programmable between 1 minute and 30 minutes, in 1 minute steps Suitable
More informationSignalist SC2. DCC servo point controller user manual
Signalist SC2 DCC servo point controller user manual 1 Contents Signalist SC2 user manual... 3 Overview... 3 Connections... 3 Power connection... 4 Accessory bus connection... 5 Track connection... 6 Frog
More informationWMX2 Parameter Manual
WMX2 Parameter Manual Revision 2.0030 2016 Soft Servo Systems, Inc. Warning / Important Notice Warning The product described herein has the potential through misuse, inattention, or lack of understanding
More informationPID-CONTROL FUNCTION AND APPLICATION
PID-CONTROL FUNCTION AND APPLICATION Hitachi Inverters SJ1 and L1 Series Deviation - P : Proportional operation I : Integral operation D : Differential operation Inverter Frequency command Fan, pump, etc.
More informationTEAM DIGITAL. SC82 Servo Controller
TEAM DIGITAL SC Servo Controller Improving the world of DCC > DCC compatible accessory decoder > Control servos motors > Output status LEDs > inputs for turnout control > 6 inputs for semaphore signaling
More informationMercury technical manual
v.1 Mercury technical manual September 2017 1 Mercury technical manual v.1 Mercury technical manual 1. Introduction 2. Connection details 2.1 Pin assignments 2.2 Connecting multiple units 2.3 Mercury Link
More informationDigital-Servo Analogue Operation. Charateristics. Description. Connection
Digital-Servo 8 3 Charateristics For Märklin oder DCC Digital systems and Analogue operation Integrated Digital decoder Switchable by locomotive functions, solenoid or proportional to speed setting Configurable
More informationHPVFP High Performance Full Function Vector Frequency Inverter
Advanced User Manual HPVFP High Performance Full Function Vector Frequency Inverter HP VER 1.00 1. HPVFP Parameter Set Overview...3 1.1. About this section...3 1.2. Parameter Structure Overview...3 1.3.
More informationSentido KNX Manual. Sentido KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium
basalte bvba hundelgemsesteenweg a 980 merelbeke belgium / 68 06 basalte Table of contents:. Introduction... 3. Installation... 4. 3. Identifying the parts... 5 General... 6 3. General functions... 7 3.
More informationAcceleration and Deceleration Control
Exercise 2 Acceleration and Deceleration Control EXERCISE OBJECTIVE To learn how to eliminate abrupt starting and stopping of an actuator with acceleration and deceleration control. DISCUSSION Acceleration
More informationVL1000 Software Version History VL1000 3/25/02 4/10/02 4/15/02 4/25/02 5/16/02 6/25/02 7/09/02 8/08/02
Page 1 of 5 SUBJECT: VL1000 Luminaire Software Version History SERIES: 1000 DISTRIBUTION: Service Centers, End Users STATUS: Routine Introduction VL1000 Software Version History This technical bulletin
More informationMX620 - MX623, MX630 - MX633
Decoder MX62 - MX623, MX63 - MX633 and Sound Decoder MX64 - MX648 Page 1 MX63 INSTRUCTION MANUAL MX621 MX642D MX621N MX63P16 PluX 16 MX632 MX632D 21-pin MTC MX642 PluX 22 MX643P22 SUBMINIATURE and MINIATURE
More information6.9 Jump frequency - Avoiding frequency resonance
E581595.9 Jump frequency - Avoiding frequency resonance : Jump frequency : Jumping width Function Resonance due to the natural frequency of the mechanical system can be avoided by jumping the resonant
More informationCT435. PC Board Mount Temperature Controller
CT435 PC Board Mount Temperature Controller Features Two RTD temperature sensor inputs: Pt100 or Pt1000. Wide temperature sensing range: -70 C to 650 C. All controller features are configurable through
More informationQuick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB
DF5-... Frequency Inverters 1 st published 22, edition 02/02 Moeller GmbH, 53105 Bonn Author: Holger Friedrich Editor: Michael Kämper Translator: Dominik Kreuzer All brand and product names are trademarks
More informationUSER S MANUAL. This manual must be considered an integral part of the projector. The user must read this manual before using the projector
575W HMI Scan light ZIPPER 575 USER S MANUAL This manual must be considered an integral part of the projector. The user must read this manual before using the projector AUTHORISED AND QUALIFIED PERSONNEL
More informationIntroduction to Servo Control & PID Tuning
Introduction to Servo Control & PID Tuning Presented to: Agenda Introduction to Servo Control Theory PID Algorithm Overview Tuning & General System Characterization Oscillation Characterization Feed-forward
More informationG320X MANUAL DC BRUSH SERVO MOTOR DRIVE
G320X MANUAL DC BRUSH SERVO MOTOR DRIVE Thank you for purchasing the G320X drive. The G320X DC servo drive is warranted to be free of manufacturing defects for 3 years from the date of purchase. Any customer
More informationTAM VALLEY DEPOT. QuadLN_S User Manual
TAM VALLEY DEPOT QuadLN_S User Manual Firmware v1.0 N3IX Engineering 25 August 2014 N3IX Engineering 2014 Contents 1 Basics... 1 1.1 Overview... 1 1.2 Servos... 2 1.3 External Power Supply... 2 1.4 Onboard
More informationRB-Rop-08 Scorpion XXL Dual 20A 6V to 28V R/C DC Motor Driver
RB-Rop-08 Scorpion XXL Dual 20A 6V to 28V R/C DC Motor Driver The Robot Power Scorpion XXL is a flexible high-performance two-channel motor controller for small to medium mobile robots such as firefighting
More informationMX620, MX62, MX63, MX64, MX64D, MX64P
Decoder MX62, MX62, MX63, MX64, MX64D, MX64P Page 1 INSTRUCTION MANUAL EDITION First common instruction manual for MX62 (SW version 3), MX62, MX63, MX64 (SW version 25) --- 26 8 1 26 9 2 26 12 1 RailCom
More informationEnhanced PID for Air Compressors F7 Drive Software Technical Manual
Software Number: VSF11020X, Drive Models: CIMR-F7UXXXXXX-096 Document Number: TM.F7SW.096, Date: 08/01/05, Rev: 05-08 Enhanced PID for Air Compressors F7 Drive Software Technical Manual This document is
More informationCHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS
CHAPTER DESCRIPTION OF PARAMETER SETTINGS.1 Group 0: User Parameters 0-00 Identity Code of AC Drive Factory setting: d# Settings None V HP 1/4 1/2 1 2 3 11V/230V d0 d2 d4 d6 d8 460V -- -- -- d3 d d7 d9
More information[ 4 ] Using pulse train input (F01 = 12)
[ 4 ] Using pulse train input (F01 = 12) Selecting the pulse train input format (d59) A pulse train in the format selected by the function code d59 can give a frequency command to the inverter. Three types
More informationIntroduction To Temperature Controllers
Introduction To Temperature Controllers The Miniature CN77000 is a full featured microprocessor-based controller in a 1/16 DIN package. How Can I Control My Process Temperature Accurately and Reliably?
More informationIntroduction. Purpose
Page 1 of 6 SUBJECT: VL1000 / VL2000 Luminaire Software SERIES: 1000/2000 DISTRIBUTION: Service Centers, End Users STATUS: Routine Introduction 10 minutes Purpose Software Version 4.8 containing updated
More informationContinental Hydraulics Installation Manual CEM-PA-A
CEMPAA Description: This closed loop PID amplifier drives a single solenoid proportional pressure or flow control valve coil up to 2.6A. It is suitable to provide precise closed loop control in pressure,
More informationProcidia Control Solutions Dead Time Compensation
APPLICATION DATA Procidia Control Solutions Dead Time Compensation AD353-127 Rev 2 April 2012 This application data sheet describes dead time compensation methods. A configuration can be developed within
More informationAppendix F: PID Control...F 1 PID Control...F 2
Appendix PID Control F Table of Contents Appendix F: PID Control........................................F 1 PID Control................................................F 2 PID Control Overview.............................................
More informationMulti-protocol decoder in Mini-format with 6 way NEM 651 plug
Multi-protocol decoder 73 51 in Mini-format with 6 way NEM 651 plug For locomotives from Arnold, Bemo, Brava, Fleischmann, Kato, Roco, Tillig, Minitrix. Features 73 51 Regulated Multi-protocol decoder
More informationAutomationdirect.com. D i r e c t L o g i c L o o p P I D C o p r o c e s s o r F P I D
Automationdirect.com D i r e c t L o g i c 4 0 5 1 6 L o o p P I D C o p r o c e s s o r F 4-1 6 P I D Order Number: F4-16PID-M TRADEMARKS Automationdirect.com is a Trademark of Automationdirect.com CoProcessor
More informationCHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3
CHAPTER MAINTENANCE AND 6 TROUBLESHOOTING In This Chapter... Maintenance and Inspection.................6 2 Monthly Inspection:..................................6 2 Annual Inspection....................................6
More informationDI 24 VDC. Stepper Axis. Dual Stepper Motion Module Applications Guide. 8 Digital Input +24 VDC Sourcing. Stepper. Contents. Programming a Stepper...
Dual Stepper Motion Module Applications Guide Stepper Stepper Axis DI 24 VDC 8 Digital Input +24 VDC Sourcing Contents Programming a Stepper...5 Setting Up Stepper Motor Operating Parameters...5 Setting
More information6.4 Adjusting PID Manually
Setting Display Parameter Setting Display Operation Display > PARAMETER or PARA key for 3 seconds (to [MODE] Menu Display) > Right arrow key (to [PID] Menu Display ) > SET/ENTER key (The setting parameter
More informationPID Control Technical Notes
PID Control Technical Notes General PID (Proportional-Integral-Derivative) control action allows the process control to accurately maintain setpoint by adjusting the control outputs. In this technical
More informationINSTRUCTION MANUAL. Non-Sound Decoder MX618 - MX634 and Sound Decoder MX640 - MX648 Page 1
Non-Sound Decoder MX618 - MX634 and Sound Decoder MX64 - MX648 Page 1 INSTRUCTION MANUAL MX618N18 Next 18 NEM 651 MX621N MX632 MX63 MTC 21 MX644C MX63P16 PluX 16 NEXT 18 DECODER SUBMINIATURE and MINIATURE
More informationMulti-function, Compact Inverters. 3G3MV Series
Multi-function, Compact Inverters 3G3MV Series There has been a great demand for inverters with more functions and easier motor control than conventional i OMRON's powerful, compact 3G3MV Series with versat
More informationGL102 Intelligent Temperature Controller User s Guide
GL102 Intelligent Temperature Controller User s Guide 1 Caution Abnormal operating conditions can lead to one or more undesirable events that, in turn, could lead to injury to personnel or damage to the
More informationCopley ASCII Interface Programmer s Guide
Copley ASCII Interface Programmer s Guide PN/95-00404-000 Revision 4 June 2008 Copley ASCII Interface Programmer s Guide TABLE OF CONTENTS About This Manual... 5 Overview and Scope... 5 Related Documentation...
More informationSpeed Feedback and Current Control in PWM DC Motor Drives
Exercise 3 Speed Feedback and Current Control in PWM DC Motor Drives EXERCISE OBJECTIVE When you have completed this exercise, you will know how to improve the regulation of speed in PWM dc motor drives.
More informationOperating Instructions
4XH35QB151210 Small General Frequency Converter Operating Instructions 220V 0.75KW 5.5KW 400V 0.75KW 15KW Please read the instruction carefully and understand the contents so that it can be installed and
More informationAL-DALI-010v 0-10v Dimmer 3-Way switch with DALI
ATX LED Consultants Inc 815-A Brazos #326 Austin Tx, 78701 512 377 6052 http://atx-led.com AL-DALI-010v 0-10v Dimmer 3-Way switch with DALI Product Description - AL-DALI wall switch with 0-10v output Combine
More informationLEDsmart + Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control
DIGINET CONTROL SYSTEMS DATA SHEET LEDsmart + Programmable between 1 minute and 30 minutes with built in multi-way control www.diginet.net.au Wall plate not included Range Overview MMTM / PB Designed in
More informationFinal Mini Project Report
Integrated System Analysis Team 1 Savath Lieng: Leader Jose Diaz: Certifier Shabuktagin Photon Khan: Rapporteur Abstract This mini project III shows an integrated system analysis. In this project, we built
More information40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR
40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR The BIDIR-340-DR is a fully solid-state motor controller that allows you to control the speed and direction of a
More informationrecognise that electronic systems are assembled from sensing, processing and out put sub-systems, including:
Electronic Systems Learners should be able to: (a) recognise that electronic systems are assembled from sensing, processing and out put sub-systems, including: sensing units: light, temperature, magnetic
More informationFibaro System Modules
Chapter 3 Fibaro System Modules 3.1 Fibaro Dimmer FGD211 Figure 3.1: Dimmer module, FGD-211 Radio controlled light dimming module, designed to work with light sources of any type. May be connected to two-wire
More informationCHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6
CHAPTER KEYPAD OPERATION 3 AND QUICKSTART In This Chapter... The GS2 Digital Keypad.....................3 2 LED Display.........................................3 2 LED Indicators.......................................3
More informationCHAPTER 8 PARAMETER SUMMARY
CHAPTER PARAMETER SUMMARY Group 0: System Parameter VFD-V Series 00-00 Identity Code Based on the model type 00-01 Rated Current Display 00-02 Parameter Reset 00-03 00-04 Star-up Display of the Drive Definitions
More informationAL-DALI-010v 0-10v Dimmer 3-Way switch with DALI
ATX LED Consultants Inc 815-A Brazos #326 Austin Tx, 78701 512 377 6052 http://atx-led.com AL-DALI-010v 0-10v Dimmer 3-Way switch with DALI Product Description - AL-DALI wall switch with 0-10v output Combine
More informationRailLinx 900 Control System. Operation Manual
RailLinx 900 Control System Operation Manual RCS America RailLinx 900 Control System Operation Manual This manual was written by RCS America Any questions, please don t hesitate to call. RCS America 2818
More informationDACPORT Low Cost, Complete P-Compatible 8-Bit DAC AD557*
a FEATURES Complete 8-Bit DAC Voltage Output 0 V to 2.56 V Internal Precision Band-Gap Reference Single-Supply Operation: 5 V ( 10%) Full Microprocessor Interface Fast: 1 s Voltage Settling to 1/2 LSB
More informationV&T Technologies Co., Ltd. Vectorque TM V6-H-M1 SERIES INVERTER ADDITIVE MANUAL (M1) V6-H Series ADDITIVE MANUAL V& T
Vectorque TM V6-H-M1 SERIES INVERTER ADDITIVE MANUAL (M1) V6-H Series ADDITIVE MANUAL V& T Change Scope Increase control function of vector control 2 with encoder speed feedback to support machine tool
More informationOVEN INDUSTRIES, INC. Model 5C7-362
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...
More informationContinental Hydraulics Installation Manual CEM-RA-A
CEM-RA-A Description: This ramp amplifier drives either single or dual solenoid proportional valve coils up to 2.6A. It is suitable to control current to either proportional directional, flow, or pressure
More informationIntroduction. Example. Table of Contents
May-17 Application Note #5532 Positioning a Stepper Motor Using Encoder Feedback on an Axis With Non-Linear Mechanics Table of Contents Introduction...1 Example...1 Open-loop operation as baseline...2
More informationVersaMax Mixed Discrete / High-Speed Counter Module
Product Description The VersaMax Mixed Discrete High-Speed Counter (HSC) module,, has twenty 24VDC positive-logic type inputs and twelve positive-logic 24VDC 0.5Amp outputs. In its default configuration,
More informationSeries 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual
THE HIGH PERFORMANCE COMPANY Series 70 Hold 1 sec. Hold 1 sec. FOR MORE INFORMATION ON THIS PRODUCT AND OTHER BRAY PRODUCTS PLEASE VISIT OUR WEBSITE www.bray.com Table of Contents 1. Definition of Terms.........................................2
More informationCompatible Products: LAC L12-SS-GG-VV-P L16-SS-GG-VV-P PQ12-GG-VV-P P16-SS-GG-VV-P T16-SS-GG-VV-P
USB Control and Configuration of the LAC (Linear Actuator Control Board) Compatible Products: LAC L12-SS-GG-VV-P L16-SS-GG-VV-P PQ12-GG-VV-P P16-SS-GG-VV-P T16-SS-GG-VV-P This note provides further information
More informationInvertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide
Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide The Invertek Optidrive E3 Frequency Inverter range is available to order from inverterdrive.com This guide is intended to complement
More informationSeries Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB
Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG 2 490 0 220 DME 2 490 0 221 DMB 2 490 0 222 Date: Aug-07 (subject to alterations) Page 1 of 36 Contents 1 FUNCTIONAL CHARACTERISTICS...
More informationHITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class
HITACHI L1-M Series Inverter Quick Reference Guide Single-phase Input 1V Class Hitachi Industrial Equipment Systems Co., Ltd. Manual No. NB5741XD December 23 Caution: Be sure to read the L1 Inverter Manual
More informationManual. ihss57-xx. Integrate Stepper Servo Motor.
ihss57-xx Integrate Stepper Servo Motor Manual Shenzhen Just Motion Control Electro-mechanics Co., Ltd TEL:+86-0755-26509689 FAX:+86-0755-26509289 www.jmc-motion.com Email:jmk@jmc-motion.com Address: Floor2,
More informationPSF-520 Instruction Manual
Communication software for HA-520/HA-680 Series PSF-520 Instruction Manual Thank you for implementing our AC servo driver HA-520, HA-680 series. The PSF-520 software sets various parameters and checks
More informationSTEPPING MOTOR EMULATION
OPERATING MANUAL SERIES SMTBD1 OPTIONAL FUNCTIONS (Version 2.0) European version 2.0 STEPPING MOTOR EMULATION OPTION C This manual describes the option "C" of the SMT-BD1 amplifier: Stepping motor emulation.
More informationChapter 2 Signal Conditioning, Propagation, and Conversion
09/0 PHY 4330 Instrumentation I Chapter Signal Conditioning, Propagation, and Conversion. Amplification (Review of Op-amps) Reference: D. A. Bell, Operational Amplifiers Applications, Troubleshooting,
More informationUser s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E
User s Manual Model US1000 Digital Indicating Controller Functions 2nd Edition Introduction This instruction manual describes the functions of the US1000 Digital Indicating Controller in detail. Read
More informationBefore you operate the inverter, the parameters that you must first program are the basic parameters.
. Main parameters Before you operate the inverter, the parameters that you must first program are the basic parameters..1 Searching for changes using the history function () : History function History
More informationTABLE OF CONTENTS. Keypad Programming Manual 1
TABLE OF CONTENTS How To Program Radios...2 Keypad Programming...2 A. Navigation...3 1. Group Parameters (CH 00)...4 2. Channel Parameters (CH 01 - CH20)...4 3. Global Parameters (GRP 00)...5 B. Group
More informationBulletin 1402 Line Synchronization Module (LSM)
Bulletin 1402 (LSM) Application Notes Table of Contents What is Synchronization?...................................... 2 Synchronization............................................. 3 1771 Modules and
More information