Keysight Technologies Parametric Instrument Accessories
|
|
- George Dorsey
- 6 years ago
- Views:
Transcription
1 Keysight Technologies Parametric Instrument Accessies Accessies Guide Technical Overview
2 Table of Contents 1. Introduction Connecting to Fixture Jumper cables ocket modules Connecting to W GND FC Connecting to Prober GND connections /C connections Accessies C accessies B1500A peripherals Connect type Cables Connect plates Adapters & connects... 24
3 1. Introduction This guide provides infmation on how to connect a prober to Keysight Technologies, Inc. semiconduct parametric measurement instruments. This guide also provides infmation on accessies f a variety of Keysight Technologies semiconduct parametric measurement instruments, such as: Keysight B1500A emiconduct Device Analyzer Keysight 4155C/4156C emiconduct Parameter Analyzer Keysight E5270B 8 slot Precision easurement ainframe Keysight E5260A 8 slot High peed easurement ainframe Keysight B2200A fa Leakage witch ainframe Keysight B2201A 14ch Low Leakage witch ainframe Keysight E5250A Low Leakage witch ainframe Figure 1.1. B1500A with Cascade prober Figure 1.2. B1500A with Vect prober Figure 1.3, B1500A with uss prober Figure 1.4. As on the probe station
4 04 Keysight Parametric Instrument Accessies Guide Technical Overview 2. Connecting to Fixture The 16442A and 16442B test fixtures have 6 triaxial input pts. You can connect fce pts of to them by using Triaxial Cable 16494A as shown in Figure 2.1. Triaxial cable 16494A m 16494A m 1-6 Fixture 16442A 16442B 2.1. Jumper cables Table 2.1. Jumper cables ini banana Pin plug 2 mm Approximately 200 mm 11 mm 7 mm As option of 16442A/16442B 16442A-811/16442B-811 f Black (2ea), Blue (2ea), Red (2ea) Parts number f Black (1ea) f Red (1ea) f Blue (1ea) 1 mm Figure 2.1. Connecting s to fixture Pin plug Pin plug 1 mm 7 mm Approximately 200 mm 7 mm 1 mm As option of 16442A/16442B 16442A-812/16442B-812 f Black (2ea), Blue (2ea), Red (2ea) Parts number f Black (1ea) f Red (1ea) f Blue (1ea) ini banana ini clip 2 mm 11 mm Approximately 200 mm 40 mm As option of 16442A/16442B 16442A-813/16442B-813 f Black (2ea), Blue (2ea), Red (2ea) Parts number f Black (1ea) f Red (1ea) f Blue (1ea) ini banana ini banana 11 mm Approximately 200 mm 2 mm As option of 16442A/16442B 16442A-814/16442B-814 f Black (2ea), Blue (2ea), Red (2ea) Parts number f Black (1ea) f Red (1ea) f Blue (1ea)
5 05 Keysight Parametric Instrument Accessies Guide Technical Overview 2.2. ocket modules Table 2.2. ocket odules N1254A inch 16442A-801/16442B-801 N1254A inch inch 43 mm 43 mm 86 mm This socket module is f measurement of virtually any device component, DIPIC, small-scale circuit A-802/16442B inch 84 mm N1254A A-803/16442B inch 0.05 inch 1 mm 8 mm 17.2 mm 1.8 mm N1254A mm 5 mm 3 mm 86 mm This socket module has two transist sockets f measurement of three lead four lead bipolar transists and FETs A-821/16442B mm 5 mm 20 mm 84 mm 3 mm aximum voltage: 200 V N1254A mm mm This socket module has a 28-pin dual-in-line socket. aximum voltage: 230 V 16442A-823/16442B mm mm 84 mm mm N1254A mm mm This socket module has an 18-pin dual-in-line socket. aximum voltage: 230 V 16442A-822/16442B mm 9 mm 9 84 mm 2.54 mm N1254A mm 86 mm This insulation board has minimal leakage current, and so is good f extremely low current measurements A-800/16442B mm 84 mm
6 06 Keysight Parametric Instrument Accessies Guide Technical Overview 3. Connecting to W 3.1. GND An has FORCE (ENE), GARD, and COON, but a GND has ENE, FORCE, and COON as shown in Figure 3.1. You need some st of GND to Kelvin adapter when connecting the GND to standard triaxial connections. Common G N D Ground unit cable 16493L m 16493L m Triaxial triaxial adapter N1254A-107 W B2200A E5250A Figure 3.2. Examples of a GND non-kelvin connection to W Figure 3.1. GND terminal CATION You should use the Keysight 16493L GND cable to connect the GND to the W; do not use a standard triaxial cable. The GND cable can handle the maximum GND current of 4.2 A, but standard triaxial cables are only rated to 1 A. (Non-Kelvin connection) Connect the triaxial connect using an adapter f GND (N1254A-107) as shown in Figure 3.2. F this part, see Table 5.10 in ection 5.6 Adapters. F parts infmation, see Table 3.1. Kelvin connection Connect the dual triaxial connect using a GND to Kelvin Adapter (N1254A-100) as shown in Figure 3.3. F this part, see Table 5.10 in ection 5.6 Adapters. F parts infmation, see Table 3.2. aximum current is restricted when the Kelvin triaxial cable is used. ee Table 3.2. Table 3.1. Parts infmation Description Qty Part number Product Ground unit cable 1.5 m (ax 4.2 A) L-001 Ground unit cable 3.0 m (ax 4.2 A) L-002 Adapter f GND (triaxial (m) triaxial (f)) N1254A-107 G N D Kelvin triaxial cable 16493K m 16493K m GND to Kelvin adapter N1254A-100 Table 3.2. Parts infmation W B2200A Ground unit cable 16493N m Description Qty Part number Product Kelvin triaxial cable 1.5 m (ax 3.0 A) K-001 Kelvin triaxial cable 3.0 m (ax 2.6 A) K-001 Ground unit cable 1.5 m N-001 GND to Kelvin adapter 1 N1254A-100 G N D Figure 3.3. Examples of a GND Kelvin connection to W W B2200A
7 07 Keysight Parametric Instrument Accessies Guide Technical Overview 3.2. An terminal is shown in Figure 3.4. Guard Common () Kelvin triaxial cable 16493K m 16493K m W B2200A B2201A Kelvin triaxial cable 16494B m 16494B m 16494B m W E5250A Figure 3.4. terminal Kelvin connection When Kelvin connection is used, connect a Keysight 16493K Kelvin triaxial cable f B2200A/B2201A as shown in Figure 3.5. F E5250A, connect a Keysight 16494B Kelvin Triaxial Cable as shown in Figure 3.5. You can also use two Keysight 16494A triaxial cables in place of one Kelvin Triaxial Cable. Connect the FORCE and ENE lines to pts separately. Non-Kelvin connection When non-kelvin connection is used, connect the Keysight 16494A triaxial cable between the and W as shown in Figure FC FC of B1500A is connected to CH and CL pt of B2200A/ B2201A by using C input cable 16494F-001 as shown in Figure 3.7. Figure 3.5. Examples of a Kelvin connection to W F C Triaxial cable 16494A m 16494A m Hcur C input cable 16494F m Hpot Lpot Lcur CH CL W E5250A Figure 3.6. Examples of a non-kelvin connection to W W B2200A B2201A Figure 3.7. Examples of a FC connection to W
8 08 Keysight Parametric Instrument Accessies Guide Technical Overview 4. Connecting to Prober 4.1. GND connections An has FORCE (ENE), GARD, and COON, but a GND has ENE, FORCE, and COON as shown in Figure 4.1. You need some st of GND to Kelvin adapter when connecting the GND to standard triaxial connections. G N D Triaxial cable 16493L m 16493L m hielding box Adapter f GND N1254A-107 Prober Common Connect plate DT Figure 4.1. GND terminal Figure 4.2. Examples of a GND non-kelvin connection CATION You should use the Keysight 16493L GND cable to connect the GND to the connect plate; do not use a standard triaxial cable. The GND cable can handle the maximum GND current of 4.2 A, but standard triaxial cables are only rated to 1 A. Non-Kelvin connection Connect the triaxial connect using an adapter f GND (N1254A-107) as shown in Figure 4.2. F this part, see Table 5.10 in ection 5.6 Adapters. F parts infmation, see Table 4.1. Table 4.1. Parts infmation Description Qty Part number Product Ground unit cable 1.5 m (ax 4.2A) L-001 Ground unit cable 3.0 m (ax 4.2A) L-002 Adapter f GND (triaxial (m) triaxial (f)) N1254A-107 G N D Kelvin triaxial cable 16493K m 16493K m hielding box Prober Kelvin connection Connect the dual triaxial connect using a GND to Kelvin Adapter (N1254A-100) as shown in Figure 4.3. F this part, see Table 5.10 in ection 5.6 Adapters. F parts infmation, see Table 4.2. aximum current is restricted when the Kelvin triaxial cable is used. ee Table 4.2. GND to Kelvin adapter N1254A-100 Table 4.2. Parts infmation Connect plate Figure 4.3. Examples of a GND Kelvin connection Description Qty Part number Product Kelvin triaxial cable 1.5 m (ax 3.0 A) K-001 Kelvin triaxial cable 3.0 m (ax 2.6 A) K-002 GND to Kelvin adapter 1 N1254A-100 DT
9 09 Keysight Parametric Instrument Accessies Guide Technical Overview 4.2. /C connections An terminal is shown in Figure 4.4. Guard Common () Kelvin triaxial cable 16493K m 16493K m hielding box Prober Figure 4.4. terminal Kelvin connection These instructions apply when all connections are Kelvin. Two probes must contact the wafer in this connection. Connect a Keysight 16493K Kelvin triaxial cable ( two Keysight 16494A triaxial cables) between the and the connect plate. Connect the FORCE and ENE lines to probes separately. Connect the triaxial connect on the probe cable as shown in Figure 4.5. To prevent oscillations, use sht cables. F parts infmation, see Table 4.3. Non-Kelvin connection These instructions apply when all connections are non-kelvin. Connect the Keysight 16494A triaxial cables between the and the Connect plate. Connect the triaxial connect on the probe cable as shown in Figure 4.6. F parts infmation, see Table 4.4. Table 4.3. Parts infmation Description Qty Part number Product Kelvin triaxial cable 1.5 m (ax 3.0 A) K-001 Kelvin triaxial cable 3.0 m (ax 2.6 A) K-002 Triaxial cable 16494A m 16494A m Connect plate Figure 4.5. Examples of a Kelvin connection Connect plate Table 4.4. Parts infmation Figure 4.6. Examples of a non-kelvin connection hielding box Prober Description Qty Part number Product Triaxial cable 1.5 m A-001 Triaxial cable 3.0 m A-002 DT DT
10 10 Keysight Parametric Instrument Accessies Guide Technical Overview Kelvin to non-kelvin connection These instructions apply when the connections up to the Connect Plate are Kelvin, but the probe is a non-kelvin connection. Kelvin triaxial cable 16493K m 16493K m hielding box Prober Connect a Keysight 16493K Kelvin triaxial cable ( two Keysight 16494A triaxial cables) between the and the Connect plate. Tee triaxial BNC DT Connect the triaxial connect on the probe cable as shown in Figure 4.7. Connect plate Triaxial cable 16494A m Connect the FORCE and ENE lines on this side of the probe input terminal. A Tee Triaxial BNC adapter can be used. F parts infmation, see Table 4.5. Note: When connecting the cable and tee connect as shown in Figure 4.7, space restrictions make an adjacent connect unusable. ince three connects are necessary f a Kelvin connection a connect plate must be used. elect the crect connect plate f your application. To make two Kelvin connections, use a Keysight 16495H. To make three Kelvin connections, use a Keysight 16495J. Figure 4.7. Examples of a Kelvin to non-kelvin connection Table 4.5. Parts infmation Description Qty Part number Product Kelvin triaxial cable 1.5 m K-001 Kelvin triaxial cable 3.0 m K-002 Triaxial cable 0.4 m A-004 Triaxial tee-connect
11 11 Keysight Parametric Instrument Accessies Guide Technical Overview A connection Each A has one Dsub control cable, one triaxial cable, and (optionally) two coaxial cables connected to it. The cables can be connected to the A inside the shielding box through the 16495K plate. C cable N1300A m N1300A m Triaxial cable and Dsub cable m m hielding box The A outputs should be connected to the DT by using triaxial cables as shown in Figure 4.8. When making IV measurements with the s, all measurements are Kelvin. The ENE line infmation is fed back to the via the Dsub cable. When making CV measurements, the four-terminal pair (4TP) connections are crectly terminated inside of the As. The As also allow f a current return path between the outer conducts to stabilize the series inductance and improve accuracy. You must connect the furnished wire between the two As to enable this feature. H R F C H R Dsub Hcur Hpot Lpot Lcur Dsub Triaxial cable and Dsub cable m m Dsub C-cur/AX in C-pot C-pot C-cur/AX in Dsub A A Connect plate 16495K Wire furnished with A (both pin terminals Prober DT Figure 4.8. Examples of an A connection Table 4.5. Parts infmation Description Qty Part number Product Triaxial cable & Dsub cable f A 1.5 m Triaxial cable & Dsub cable f A 3.0 m C cable f B1500A 1.5 m 1 N1300A-001 C cable f B1500A 3.0 m 1 N1300A-002 Connect plate K
12 12 Keysight Parametric Instrument Accessies Guide Technical Overview C positioner-based probing mode The C should be connected to the DT by using triaxial cables as shown in Figure 4.9. C cable N1301A m hielding box When making IV measurements using the s, the outputs of the C function exactly the same as the Kelvin outputs of an (both FORCE and ENE lines are available). C N1301A-100 Note: In Figure 4.9 the ENE lines are not used. When making CV measurements using the FC, only the FORCE outputs of the C are used. C FORCE output1 cresponds to CH, and C FORCE output2 cresponds to CL. The C can be fixed on the prober by using C agnet tand (N1301A-110). F C Hcur H pot Lpot Lcur Prober DT Connect plate 16495K Figure 4.9. Examples of a C remote docking mode Table 4.9. Parts infmation Description Qty Part number Product C unify unit (C) 1 N1301A-100 C unify unit cable (3.0 m) 1 N1301A-102 Connect plate K
13 13 Keysight Parametric Instrument Accessies Guide Technical Overview 5. Accessies 5.1. C accessies B1500A has the multi frequency capacitance measurement unit (FC). There are two types of C connection as follows. tandard four terminal pair (4TP) connection C positioner-based probing mode Accding to your situation, you can select the type of connection. Figure 5.1. tandard four terminal pair (4TP) Figure 5.2. C positioner-based probing
14 14 Keysight Parametric Instrument Accessies Guide Technical Overview Table 5.1. C accessies overview N1300A-001/N1300A F-001 N1301A-100 N1301A-100 N1301A-100 N1301A-102 C w/c Cable, GW N1301A-110 C w/c magnet N1301A-200 N1301A-201 Pin cable f GW GW w/gw cable
15 15 Keysight Parametric Instrument Accessies Guide Technical Overview Table 5.2. C accessies item list Item Description OP instruction N1300A C cable f B1500A N1300A-001 C cable f B1500A (1.5 m) N1300A-002 C cable f B1500A (3.0 m) N1301A C accessies f B1500 N1301A-100 C unify unit (C) N1301A-102 C unify unit cable (3 m) N1301A-110 C magnet stand To fix C on prober top etc. N1301A-200 Guard switch unit (GW) Need to be specified with N1301A-201 N1301A-202. N1301A-201 Guard switch unit cable (1 m) Please specify N1301A-201 N1302A-202 when N1301A-200 is dered. N1301A-202 Guard switch unit cable (3 m) 16494F C input cable 16494F-001 C input cable (2 m) 5.2. B1500A peripherals Table 5.3. B1500A peripherals overview 16444A A A A-003 Table 5.4. B1500A peripherals item list Item Description OP instruction 16444A B1500A accessies 16444A-001 B keyboard Keyboard includes mouse pad and mouse pointer 16444A-002 B mouse B ouse 16444A-003 tylus pen F use with the B1500A touch screen
16 16 Keysight Parametric Instrument Accessies Guide Technical Overview 5.3. Connect type There are two main styles of Kelvin connections. When connecting instruments together, you need to make sure that you have the crect type of Kelvin triaxial cables. Table 5.5. Overview of instrument connect types B1500A Type A Type A connects have two screws, one guide pin, and two triaxial terminals. Type B connects have one screw and two triaxial terminals. These connects are also different in their width and thickness. 4156C+41501B Type A 4155C ingle triaxial E5260A/E5270B Type A B2200A/B2201A inputs Type A
17 17 Keysight Parametric Instrument Accessies Guide Technical Overview Table 5.5. Overview of instrument connect types, (continued) B2200A/B2201A outputs Type B E5250A inputs Type B E5250A outputs (E5252A cards) Type B 16442A/B Type A 16493K/16494B/16493N cables Type A 16494B cable Type B
18 18 Keysight Parametric Instrument Accessies Guide Technical Overview 5.4. Cables everal possibilities exist f connecting the ource onit nits (s) to the DT. The great variety of available cables can be categized into mainly three types: Table 5.6. cables overview 16493K 16494B Triaxial cables have three layers leads: a center conduct f the signal, a middle conduct that is actively driven to be at the same potential as the center conduct to eliminate leakage currents, and a grounded (Common) outer conduct. Kelvin triaxial cables are similar to triaxial cables, except that both the and lines from the run through the same cable. The and lines share a common driven guard and a common outer shield. Kelvin triaxial cables typically give better low-current measurement perfmance than you would get from using two separate triaxial cables f the and lines. The GND cable is a special triaxial cable designed to handle the large currents (up to 4.2 A) that the ground unit can sink. In the GND cable the center conduct is ENE, the middle conduct is FORCE, and the outer conduct is Common. Kelvin triaxial cable Kelvin triaxial cable Connect type Type A Type A Type B W input W output Length option B1500A E526X E527X 415X B220XA E5250A B220XA E5250A 0.4 m 0.8 m 1.5 m 3.0 m 4.0 m NG NG NG N/A N/A 16493K K-002 N/A NG NG NG N/A 16494B B B-002 N/A NG NG NG NG NG NG
19 19 Keysight Parametric Instrument Accessies Guide Technical Overview Table 5.6. cables overview, (continued) A 16493J Triaxial & Dsub cable F A Triaxial cable Interlock cable Connect type Triax B1500A E526X N/A E527X 415X N/A N/A N/A W input B220XA N/A N/A E5250A N/A N/A W output B220XA N/A N/A E5250A N/A N/A Length option 0.4 m N/A 16494A-004 N/A 0.8 m N/A 16494A-003 N/A 1.5 m A J m A J m N/A 16494A-005 N/A Table 5.7. GND cables overview 16493N 16493L Ground unit cable Ground unit cable Connect type Type A Triaxial Triaxial GND B1500A N/A E526X N/A E527X N/A 415X N/A N/A N/A N/A W input B220XA E5250A NG W output B220XA NG E5250A NG Length option 1.5 m 16493N L m N/A 16493L-002
20 20 Keysight Parametric Instrument Accessies Guide Technical Overview 5.5. Connect plates The following connect plates wk with a variety of Keysight semiconduct parametric measurement instruments, such as the B1500, B2200/B2201, E5250, E5260/E5270, 4155/4156 and Prober vend also provides connect plates. If you need the infmation of those connect plates, please kindly contact each prober vend. If you need parts to fix a connect plate, see Table 5.8. Order the quantity you need. (The number of holes in a connect plate is four.) Table 5.8. Parts infmation to fix connect plates Description Qty Part number Product crew pring washer Terminal washer Nut Table 5.9. Connect plates 16495F Half size connect plate f matrix 16495F-001 has 12 triaxial through connects (female to female), an Intlk connect, and a GND connect (triaxial through, female to female). The back of the Intlk connect is designed f soldering F-002 has 12 triaxial connects, an Intlk connect, and a GND connect. The back of each connect is designed f soldering G Full size connect plate f matrix 16495G-001 has 24 triaxial through connects (female to female), an Intlk connect, and a GND connect (triaxial through, female to female). The back of the Intlk connect is designed f soldering G-002 has 24 triaxial connects, an Intlk connect, and a GND connect. The back of each connect is designed f soldering H Half size connect plate f analyzer 16495H-001 has 6 triaxial through connects (female to female), 6 BNC through connects (female to female), an Intlk connect, and a GND connect (triaxial through, female to female). The back of the Intlk connect is designed f soldering H-002 has 6 triaxial connects, 6 BNC connects, an Intlk connect, and a GND connect. The back of each connect is designed f soldering J Half size connect plate f analyzer 16495J-001 has 8 triaxial through connects (female to female), 4 BNC through connects (female to female), an Intlk connect, and a GND connect (triaxial through, female to female). The back of the Intlk connect is designed f soldering J-002 has 8 triaxial connects, 4 BNC connects, an Intlk connect, and a GND connect. The back of each connect is designed f soldering K Half size connect plate with universal cable holder 16495K-001 does not have any connects. This plate provides the cable hole and the cover with rubber used to block the light from the cable hole. This plate will be used with the Keysight E5288A Atto /witch nit (A) the Keysight N1301A-200 Guard witch nit (GW) that will be installed in the shielding box. The cable hole is to pass the cables from the A GW to the instrument such as the Keysight B1500A, E5270B, and so on. And the cables will be fixed to the shielding box by using the cover with rubber that will close the opening of the cable hole.
21 21 Keysight Parametric Instrument Accessies Guide Technical Overview A. Front view Common INPT 1 1 Guard (sense) Triaxial connect (f ) ignal line 9 10 Common Coaxial connect (f FC) Common Triaxial connect (f GND) GND Intlk! INTLK terminal B. Rear view Triaxial connect Ground terminal Common terminal Triaxial connect Ground terminal Common terminal The difference between the Keysight 16495F, H and J is the number of the triaxial and coaxial connects. Coaxial connect Coaxial connect INTLK terminal Triaxial connect (f GND) INTLK terminal Keysight 16495H-001 Keysight 16495H-002 Triaxial connect (f GND) Figure 5.3. Front view and rear view of connect plate
22 22 Keysight Parametric Instrument Accessies Guide Technical Overview Ø 3.2 INPT etal cover GND Intlk! nit: mm etal cover Keysight 16495H-002 (The difference between the Keysight F, H and J is the number of the triaxial and coaxial connects.) Note: etal cover is f preventing electrical shock. etal cover is furnished with F/G/H/J-002 only Figure 5.4. Dimensions of the connect plate (Keysight 16495F/H/J) Triaxial Coaxial Triaxial Coaxial A. Connect type (16495F/G/H/J-001) B. older type (16495F/G/H/J-002) Figure 5.5. Connection type of connect plate (rear)
23 23 Keysight Parametric Instrument Accessies Guide Technical Overview Ø nit: mm Figure 5.6. Dimensions of the connect plate (Keysight 16495G)
24 24 Keysight Parametric Instrument Accessies Guide Technical Overview 5.6. Adapters and connects If you need to make a connection between a triaxial connect and a coaxial connect, use a triaxial-coaxial adapter. Table Parts infmation Item Description Qty Part number Illustration Table 5.10 shows the adapter infmation provided by Keysight. If you need an adapter which is not provided, contact a local parts vend. WARNING To avoid injury, always be sure to use a shielding box and Interlock when you make a measurement. N1254A-100 N1254A-101 N1254A-102 GND to Kelvin adapter Triaxial (m) Coaxial (f) Triaxial (f) Coaxial (m) m Common f f Do not use the adapters in Table 5.10 when the GARD line connects to the outer conduct of the connect adapter. Because they connect GARD line and outer conduct of the connect adapter, the potential of the GARD terminal is equal to the output voltage and there is a potential f high voltage electrical shock at the adapter and connect. N1254A-103 N1254A-104 N1254A-105 N1254A-106 N1254A-107 Triaxial (m) Coaxial (f) Triaxial (f) Coaxial (m) Triaxial (f) Coaxial (m) Triaxial (m) Coaxial (f) Triaxial (m) Triaxial (f)
25 25 Keysight Parametric Instrument Accessies Guide Technical Overview Keysight B2900A eries Precision ource/easure nit F me infmation on Keysight Technologies products, applications services, please contact your local Keysight office. The complete list is available at: Keysight B1500A emiconduct Device Analyzer Keysight B1505A Power Device Analyzer/Curve Tracer mykeysight A personalized view into the infmation most relevant to you. Three-Year Warranty Keysight s commitment to superi product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, wldwide. Keysight Assurance Plans p to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. Keysight Technologies, Inc. DEKRA Certified IO 9001:2008 Quality anagement ystem Keysight Channel Partners Get the best of both wlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. Americas Canada (877) Brazil exico nited tates (800) Asia Pacific Australia China Hong Kong India Japan 0120 (421) 345 Kea alaysia ingape Taiwan Other AP Countries (65) Europe & iddle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia pain weden witzerland Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) nited Kingdom F other unlisted countries: (BP ) This infmation is subject to change without notice. Keysight Technologies, Published in A, August 3, EN
Keysight Technologies Making Current-Voltage Measurement Using SMU
Keysight Technologies Making Current-Voltage Measurement Using SMU Keysight B2901A/02A/11A/12A Precision Source/Measure Unit Demonstration Guide Introduction The Keysight Technologies, Inc. B2901A/02A/11A/12A
More informationKeysight Technologies Making Field Effect Transistor Characterization Using SMU
Keysight Technologies Making Field Effect Transistor Characterization Using SMU B2900A Precision Source/Measure Unit Demo Guide Introduction The Keysight s B2900A Series Precision Source/Measure Unit (SMU)
More informationKeysight Technologies Using an External Trigger to Generate Pulses with the B2960A
Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A B2960A 6.5 Digit Low Noise Power Source Demo Guide 02 Keysight Using an External Trigger to Generate Pulses with the B2960A
More informationKeysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V
Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V B1505A Power Device Analyzer/Curve Tracer Application Note Introduction The input, output and reverse transfer capacitance of
More informationKeysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview
Keysight Technologies N9398C/F/G and N9399C/F DC Block Technical Overview Introduction Key Features Maximize your operating range - 26.5, 50 or 67 GHz Improve calibration accuracy with exceptional return
More informationKeysight E5063A ENA Series Network Analyzer
Keysight E5063A ENA Series Network Analyzer 100 khz to 500 M/1.5 G/3 G/4.5 G/6.5 G/8.5 G/14 G/18 GHz Configuration Guide 02 Keysight E5063A ENA Series Network Analyzer - Configuration Guide Ordering Guide
More informationKeysight Technologies Accurate Capacitance Characterization at the Wafer Level
Keysight Technologies Accurate Capacitance Characterization at the Wafer Level 4080 Series Parametric Test Systems Application Note Introduction The continuing trend of decreasing device geometries of
More informationKeysight Technologies Migrating Balanced Measurements from the
Keysight Technologies Migrating Balanced Measurements from the HP 8903B to the Keysight U8903A Audio Analyzer Application Note 02 Keysight Migrating Balanced Measurements from the HP 8903B to the U8903A
More informationKeysight Technologies
Keysight Technologies Internal ate Resistance Measurement Using the B1505A Application Note Introduction Power MOFET and IBT internal gate resistance is an important device paramteter, since it can limit
More informationKeysight Technologies
Keysight Technologies Easily Create Power Supply Output Sequences with Data Logging Application Brief 02 Keysight Easily Create Power Supply Output Sequences with Data Logging - Application Brief Why is
More informationKeysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.
Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer Application Note Introduction Excellent impedance measurement accuracy and repeatability
More informationKeysight Technologies Resistance Measurements Using the B2900A Series of SMUs
Keysight Technologies Resistance urements Using the B2900A Series of SMUs Application Note Keysight B2901A Precision SMU, 1ch, 100 fa resolution, 210, 3A DC/10.5 A pulse Keysight B2902A Precision SMU,
More informationKeysight Technologies RF & Microwave Attenuators. Performance you can count on
Keysight Technologies RF & Microwave Attenuators Performance you can count on Key Features High reliability and exceptional repeatability reduce downtime Excellent RF specifications optimize test system
More informationKeysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note
Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer Application Note Introduction Ultra-wideband (UWB) is a rapidly growing technology that is used to transmit
More informationKeysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet
Keysight Technologies N6850A Broadband Omnidirectional Antenna Data Sheet 02 Keysight N6850A Broadband Omnidirectional Antenna - Data Sheet Industries and Applications Spectrum monitoring and signal location,
More informationKeysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet
Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes Data Sheet Introduction The Keysight Technologies, Inc. N2792A/93A and N2818A/19A differential probes provide the
More informationKeysight Technologies
Keysight Technologies Easily Create Power Supply Output Sequences with Data Logging Application Brief 02 Keysight Easily Create Power Supply Output Sequences with Data Logging - Application Brief Why is
More informationKeysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview
Keysight Technologies 8745C 1 MHz to 18 GHz Preamplifier Technical Overview 2 Keysight 8745C 1 MHz to 18 GHz Preamplifier Technical Overview Introduction The Keysight Technologies, Inc. 8745C preamplifier
More informationKeysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A
Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A B2961A/B2962A 6.5 Digit Low Noise Power Source Application Note Introduction Resistance measurement is one of the most
More informationKeysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.
Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter Application Note Introduction Exceptional accuracy and repeatability DC bias function
More informationKeysight E5063A ENA Vector Network Analyzer
Keysight E5063A ENA Vector Network Analyzer 100 khz to 500 M/1.5 G/3 G/4.5 G/6.5 G/8.5 G/14 G/18 GHz Configuration Guide 02 Keysight E5063A ENA Vector Network Analyzer - Configuration Guide Ordering Guide
More informationKeysight Technologies 8490G Coaxial Attenuators. Technical Overview
Keysight Technologies 8490G Coaxial Attenuators Technical Overview Introduction Key Specifications Maximize your operating frequency range for DC to 67 GHz application Minimize your measurement uncertainty
More informationKeysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note
Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode Application Note Introduction Keysight B1500A Semiconductor Device Analyzer Controlled dynamic recovery with 100
More informationKeysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview
Keysight Technologies 8745C 1 MHz to 18 GHz Preamplifier Technical Overview 2 Keysight 8745C 1 MHz to 18 GHz Preamplifier Technical Overview Introduction The Keysight Technologies, Inc. 8745C preamplifier
More informationKeysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.
Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter Application Note Introduction Highly accurate and repeatable measurements DC bias function
More informationKeysight Technologies MEMS On-wafer Evaluation in Mass Production
Keysight Technologies MEMS On-wafer Evaluation in Mass Production Testing at the Earliest Stage is the Key to Lowering Costs Application Note Introduction Recently, various devices using MEMS technology
More informationHP 4155B/4156B Semiconductor Parameter Analyzer Product Note-3 Prober Connection Guide. HP 4155B/4156B Semiconductor Parameter Analyzer
HP 4155B/4156B Semiconduct Parameter Analyzer Product Note-3 Connection Guide HP 4155B/4156B Semiconduct Parameter Analyzer - CONTENTS - 1. Introduction 2. General Infmation 2-1. Safety Precautions - -
More informationKeysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option
Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option For Keysight 3000T, 4000A, and 6000A X-Series Oscilloscopes Data Sheet Introduction Frequency Response Analysis (FRA) is often
More informationKeysight Technologies Simultaneous Measurements with a Digital Multimeter
Keysight Technologies Simultaneous Measurements with a Digital Multimeter Application Brief Test Challenges: Making more confident measurements Making dual measurements in less time 02 Keysight Simultaneous
More informationKeysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview
Keysight Technologies N9398C/F/G and N9399C/F DC Block Technical Overview Introduction Key Features Maximize your operating range - 26.5, 50 or 67 GHz Improve calibration accuracy with exceptional return
More informationKeysight Technologies Power of Impedance Analyzer
Keysight Technologies Power of Impedance Analyzer - Comparison to Network Analyzer Application Note Uncover real characteristics Introduction Keysight s impedance analyzers are the only instruments on
More informationKeysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note
Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter Application Note Introduction This application note explains the application procedure for using the
More informationKeysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis
Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis Application Brief Introduction Keysight Technologies, Inc. announces a new 32 Gb/s pattern
More informationKeysight Technologies Waveguide Power Sensors. Data Sheet
Keysight Technologies Waveguide Power Sensors Data Sheet 02 Keysight Waveguide Power Sensors - Data Sheet Make accurate and reliable measurements in the 50 to 110 GHz frequency range with Keysight s family
More informationKeysight Technologies Achieving Accurate E-band Power Measurements with E8486A Waveguide Power Sensors. Application Note
Keysight Technologies Achieving Accurate E-band Power Measurements with Waveguide Power Sensors Application Note Introduction The 60 to 90 GHz spectrum, or E-band, has been gaining more millimeter wave
More informationKeysight 8762F Coaxial Switch 75 ohm
Keysight 8762F Coaxial Switch 75 ohm Technical Overview DC to 4 GHz Exceptional repeatability over 1 million cycle life Excellent isolation The 8762F brings a new standard of performance to 75 ohm coaxial
More informationKeysight Technologies 85072A 10-GHz Split Cylinder Resonator. Technical Overview
Keysight Technologies 85072A 10-GHz Split Cylinder Resonator Technical Overview 02 Keysight 85072A 10-GHz Split Cylinder Resonator - Technical Overview Part of the complete turn-key solution for the IPC
More informationKeysight Technologies Phase Noise X-Series Measurement Application
Keysight Technologies Phase Noise X-Series Measurement Application N9068C Technical Overview Phase noise measurements with log plot and spot frequency views Spectrum and IQ waveform monitoring for quick
More informationKeysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note
Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer Application Note Introduction This note details the input impedance of the U8903B Audio Analyzer, and shows that this needs to
More informationKeysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview
Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions Technical Overview 02 Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions
More informationKeysight HMMC-1002 DC 50 GHz Variable Attenuator
Keysight HMMC-1002 DC 50 GHz Variable Attenuator 1GG7-8001 Data Sheet Features Specified frequency range: DC to 26.5 GHz Return loss: 10 db Minimum attenuation: 2.0 db Maximum attenuation: 30.0 db 02 Keysight
More informationKeysight Technologies NFA Noise Figure Analyzer. Configuration Guide
Keysight Technologies NFA Noise Figure Analyzer Configuration Guide Noise Figure Analyzer Overview Over 50 years of noise figure leadership Dedicated Noise Figure Analyzer Hard specifications to 26.5 GHz
More informationKeysight Technologies P9400A/C Solid State PIN Diode Transfer Switches
Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches P9400A 100 MHz to 8 GHz PIN transfer switch P9400C 100 MHz to 18 GHz PIN transfer switch Technical Overview Key Features Minimize
More informationKeysight Technologies E1834E/G/J/M/Z Mounted Beam Delivery Optics. Preliminary Data Sheet
Keysight Technologies E1834E/G/J/M/Z Mounted Beam Delivery Optics Preliminary Data Sheet The Keysight Technologies, Inc. E1834 family of beam delivery optics uses high performance mounts to meet the pointing
More informationKeysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet
Keysight Technologies N4983A Multiplexer and Demultiplexer Data Sheet 02 Keysight N4983A Multiplexer and Demultiplexer - Data Sheet N4983A-M40 44 Gb/s multiplexer Features Wide operating range, 2 to 44
More informationKeysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note
Keysight Technologies Differences in Application Between Dividers and Splitters Application Note 02 Keysight Differences in Application Between Dividers and Splitters Application Note Introduction dividers
More informationKeysight Technologies Measuring Low Current Consumption with a Digital Multimeter
Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter Application Brief Test Challenges: Characterizing the power consumption of a battery powered device Testing the current
More informationKeysight Technologies N4985A System Amplifiers
Keysight Technologies N4985A System Amplifiers Data Sheet N4985A-P15 10 MHz to 50 GHz N4985A-P25 2 to 50 GHz N4985A-S30 100 khz to 30 GHz N4985A-S50 100 khz to 50 GHz Exceptional gain and power performance
More informationKeysight Technologies How to Easily Create an Arbitrary Waveform Without Programming. Application Note
Keysight Technologies How to Easily Create an Arbitrary Waveform Without Programming Application Note 02 Keysight How to Easily Create an Arbitrary Waveform Without Programming - Application Note Creating
More informationKeysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers
Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers N4690 Series, 2-port Microwave ECal 85090 Series, 2-port RF ECal N4430 Series, 4-port ECal N7550 Series, 2-port
More informationKeysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet
Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors.1 to 5 GHz Data Sheet Introduction Features and Description Exceptional flatness Broadband from.1 to 5 GHz Extremely temperature stable Environmentally
More informationKeysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note
Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently Application Note Introduction In many applications, such as radar, pulsed lasers, and applications that employ
More informationKeysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview
Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter Technical Overview E4981A Capacitance Meter The E4981A capacitance meter provides the best combination
More informationKeysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers
Keysight Technologies Using a Network and Impedance Analyzer to Evaluate 13.56 MHz RFID Tags and Readers/Writers Application Note L C R f 0 = 2 1 π L C Introduction RFIDs, also called non-contact IC cards
More informationKeysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors
Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors Keysight 423B Data Sheet Keysight 8470B Keysight 8472B Keysight 8473B Keysight 8473C Introduction Excellent broadband
More informationKeysight Technologies HMMC GHz High-Gain Amplifier
Keysight Technologies HMMC-5620 6-20 GHz High-Gain Amplifier Data Sheet Features Wide-frequency range: 6-20 GHz High gain: 17 db Gain flatness: ± 1.0 db Return loss: Input 15 db Output 15 db Single bias
More informationKeysight Technologies How to Read Your Power Supply s Data Sheet. Application Note
Keysight Technologies How to Read Your Power Supply s Data Sheet Application Note Introduction If you are designing electronic devices and you need to power up a design for the first time, there s a good
More informationKeysight Technologies Medalist i1000d Boundary Scan Debug
Keysight Technologies Medalist i1000d Boundary Scan Debug White Paper By William Xiao, ICT Technical Marketing Engineer Keysight Technologies Introduction With Boundary scan test technology being more
More informationKeysight Technologies PXI Vector Network Analyzer Series. Drive down the size of test
Keysight Technologies PXI Vector Network Analyzer Series Drive down the size of test 02 Keysight PXI Vector Network Analyzer Series - Brochure Full Two-Port VNA that Fits in Just One Slot When you need
More informationKeysight Technologies N9310A RF Signal Generator
Keysight Technologies N9310A RF Signal Generator 02 Keysight N9310A RF Signal Generator Brochure All the capability and reliability of a Keysight instrument you need at a price you ve always wanted Reliable
More informationKeysight Technologies USB Preamplifiers
Keysight Technologies USB Preamplifiers U77/A 1 MHz to 4 GHz U77/C 1 MHz to 6. GHz U77/F to GHz Technical Overview Keysight USB Preamplifiers U77A/C/F - Technical Overview Key Features and Benefits Automatic
More informationKeysight Technologies Pulsed-IV Parametric Test Solutions. Selection Guide
Keysight Technologies Pulsed-IV Parametric Test Solutions Selection Guide Introduction Pulsed-IV parametric testing is becoming an increasingly common requirement for the development of semiconductor process
More informationKeysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300. Application Brief
Keysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300 Application Brief Introduction New information technology, the Internet of Things (IoT) is changing
More informationKeysight Technologies Measuring Power BJT Electrical Characteristics using the B1505A
Keysight Technologies Measuring Power BJT Electrical Characteristics using the B1505A B1505A Power Device Analyzer/Curve Tracer Application Note Introduction The Keysight Technologies, Inc. B1505A Power
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationKeysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options
Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options Data Sheet For InfiniiVision 3000, 4000 and 6000 X-Series Oscilloscopes Achieve cost-effective analysis of your switching mode
More informationKeysight Technologies Measuring Insulating Material Resistivity Using the B2985A/87A
Keysight Technologies Measuring Insulating Material Resistivity Using the B2985A/87A Keysight B2985A/B2987A Electrometer/High Resistance Meter Technical Overview Introduction The Keysight B2985A and B2987A
More informationKeysight Technologies Measuring Insulating Material Resistivity Using the B2985A/87A
Keysight Technologies Measuring Insulating Material Resistivity Using the B2985A/87A Keysight B2985A/B2987A Electrometer/High Resistance Meter Application Note Introduction The Keysight B2985A and B2987A
More informationKeysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.
Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters Application Note 02 Keysight Understanding the Importance of Maximum Power Point Tracking
More informationIntroduction. Part 1. Introduction...2
Keysight Technologies Simple Scalar Network Analysis of Frequency Converter Devices using the U2000 USB Power Sensor Series with the ENA Network Analyzer Application Note Introduction This application
More informationKeysight Technologies Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note
Keysight Technologies Split Post Dielectric Resonators for Dielectric Measurements of Substrates Application Note Introduction The Keysight Technologies, Inc. split post dielectric resonator (SPDR) provides
More informationKeysight N9310A RF Signal Generator
Keysight N9310A RF Signal Generator 9 khz to 3.0 GHz Data Sheet 02 Keysight N9310A RF Signal Generator - Data Sheet Definitions and Conditions Specifications describe the performance of parameters that
More informationKeysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz. Technical Overview
Keysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz Technical Overview Introduction The Keysight Technologies, Inc. active differential probes provide high
More informationIntroduction. Part 1. Introduction...2
Keysight Technologies Simple Scalar Network Analysis of Frequency Converter Devices using the U2000 USB Power Sensor Series with the ENA Network Analyzer Application Note Introduction This application
More informationKeysight Technologies Measuring Dielectric Properties Using Keysight s Materials Measurement Solutions
Keysight Technologies Measuring Dielectric Properties Using Keysight s Materials Measurement Solutions 02 Keysight Measuring Dielectric Properties Using Keysight s Materials Measurement Solutions - Brochure
More informationKeysight Technologies Triggering on and Decoding the PSI5 Sensor Serial Bus
Keysight Technologies Triggering on and Decoding the PSI5 Sensor Serial Bus Using Keysight InfiniiVision X-Series Oscilloscopes Application Note Introduction The Peripheral Sensor Interface 5 (PSI5) serial
More informationKeysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.
Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer Application Note Introduction RF IN RF OUT Waveform Generator Pulse Power Amplifier
More informationKeysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes. Data Sheet
Keysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes Data Sheet 02 Keysight N2750A/51A/52A InfiniiMode Differential Active Probes Data Sheet Key Features Measurement versatility
More informationKeysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox
Keysight Redefines 50 GHz Portability Get a $30k Credit When You Move Up to FieldFox 02 Keysight Keysight Redefines 50 GHz Portability - Brochure For over 20 years, the 8565 has been the only 50 GHz portable
More informationKeysight Technologies Pulsed-IV Parametric Test Solutions. Selection Guide
Keysight Technologies Pulsed-IV Parametric Test Solutions Selection Guide Introduction Pulsed-IV parametric testing is becoming an increasingly common requirement for the development of semiconductor process
More informationKeysight Technologies VOR and ILS Radio Navigation Receiver Test Using Option 302 for Keysight Signal Sources. Application Note
Keysight Technologies VOR and ILS Radio Navigation Receiver Test Using Option 302 for Keysight Signal Sources Application Note Introduction The Keysight X-series (EXG and MXG) analog and vector signal
More informationKeysight Technologies Secondary Radar Transponder Testing Using the 8990B Peak Power Analyzer. Application Note
Keysight Technologies Secondary Radar Transponder Testing Using the 8990B Peak Power Analyzer Application Note Introduction After a brief review of radar systems and the role of transponders, this application
More informationKeysight Technologies x1149 Boundary Scan Analyzer. Data Sheet
Keysight Technologies x1149 Boundary Scan Analyzer Data Sheet 02 Keysight x1149 Boundary Scan Analyzer - Data Sheet Overview Product description The Keysight Technologies, Inc. x1149 boundary scan analyzer
More informationKeysight Technologies Improve the Accuracy and Efficiency for Organic-Thin Film Transistor (Organic-TFT) Characterization
Keysight Technologies Improve the Accuracy and Efficiency for Organic-Thin Film Transistor (Organic-TFT) Characterization B1500A Semiconductor Device Analyzer Application Note Introduction Organic materials
More informationKeysight Technologies 87222C/D/E Coaxial Transfer Switches
Keysight Technologies 87C/D/E Coaxial Transfer Switches dc to 6.5, 0, 50 GHz Technical Overview High Performance Transfer Switches for Micro wave and RF Instrumentation and Systems Exceptional repeatability
More informationKeysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors Demo Guide Introduction This demonstration guide helps you to get familiar with the basic setup and configuration
More informationKeysight Technologies U9391C/F/G Comb Generators. U9391C (10 MHz to 26.5 GHz) U9391F (10 MHz to 50 GHz) U9391G (10 MHz to 67 GHz) Technical Overview
Keysight Technologies U9391C/F/G Comb Generators U9391C (10 MHz to 26.5 GHz) U9391F (10 MHz to 50 GHz) U9391G (10 MHz to 67 GHz) Technical Overview Key Features Excellent amplitude and phase flatness enable
More informationKeysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet
Keysight M940xA PXIe Optical Extenders for Instrumentation Data Sheet Overview Introduction The Keysight Technologies, Inc. Optical Extenders for Instruments can transmit your RF or Microwave signal without
More informationKeysight Quickly Generate Power Transients for Testing Automotive Electronics. Application Note
Keysight Quickly Generate Power Transients for Testing Automotive Electronics Application Note Introduction Electronic control units (ECUs) and other automotive electronic devices must be immune to the
More informationKeysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes
Keysight N8836A PAM-4 Measurement Application For S-Series, 90000A, V-Series, 90000 X-Series, 90000 Q-Series, and Z-Series Oscilloscopes Characterize electrical pulse amplitude modulated (PAM) signals
More informationKeysight Technologies MATLAB Data Analysis Software Packages
Keysight Technologies MATLAB Data Analysis Software Packages For Keysight Oscilloscopes Data Sheet 02 Keysight MATLAB Data Analysis Software Packages - Data Sheet Enhance your InfiniiVision or Infiniium
More informationKeysight Technologies mm-wave Source Modules from OML, Inc. for PSG Signal Generators. Technical Overview
Keysight Technologies mm-wave Source Modules from OML, Inc. for PSG Signal Generators Technical Overview 02 Keysight mm-wave Source Modules from OML, Inc. for PSG Signal Generators - Technical Overview
More informationKeysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter
Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter Application Brief Test Challenges: Measuring DC voltage and current with a single digital multimeter Measuring watts
More informationKeysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet
Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes Data Sheet 02 Keysight N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes
More informationKeysight Technologies Maximizing the Life Span of Your Relays
Keysight Technologies Maximizing the Life Span of Your Relays Application Note This application note is for automated test engineers and engineers who use a datalogger for R&D or production testing. In
More informationKeysight Technologies Wide Range DC Current Biased Inductance Measurement
Keysight Technologies Wide Range DC Current Biased Inductance Measurement Application Note Keysight E4980A Precision LCR Meter Keysight 4284A Precision LCR Meter Keysight 42841A Bias Current Source Introduction
More informationKeysight Technologies E8257D PSG Microwave Analog Signal Generator. Configuration Guide
Keysight Technologies E8257D PSG Microwave Analog Signal Generat Configuration Guide This guide assists in the dering process of the E8257D PSG microwave analog signal generat. Standard product includes
More informationKeysight Technologies Reliable High-Resistance Measurements Using the B2985A/87A
Keysight Technologies eliable High-esistance Measurements Using the B2985A/87A Electrometer/High esistance Meter Application Note Introduction Previously, high resistance and resistivity measurements have
More informationKeysight Technologies Photodiode Test Using the Keysight B2980A Series
Keysight Technologies Photodiode Test Using the Keysight B2980A Series B2981A/83A Femto/Picoammeter B2985A/87A Electrometer/High Resistance Meter Application Note Introduction A photodiode (PD) is a semiconductor
More informationKeysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet
Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator Data Sheet Introduction Sub-7 ps fall time (90%-10%) Sub-9 ps rise time (10%-90%) Fully differential output
More information