HP 4155B/4156B Semiconductor Parameter Analyzer Product Note-3 Prober Connection Guide. HP 4155B/4156B Semiconductor Parameter Analyzer

Size: px
Start display at page:

Download "HP 4155B/4156B Semiconductor Parameter Analyzer Product Note-3 Prober Connection Guide. HP 4155B/4156B Semiconductor Parameter Analyzer"

Transcription

1 HP 4155B/4156B Semiconduct Parameter Analyzer Product Note-3 Connection Guide HP 4155B/4156B Semiconduct Parameter Analyzer

2 - CONTENTS - 1. Introduction 2. General Infmation 2-1. Safety Precautions - - Interlock Circuit 2-2. Low Current Measurement - Guarding 2-3. Low Resistance Measurement - Kelvin Connections 2-4. Probe 3. Connecting to a 3-1. Installing the Connect Plate 3-2. Interlock Connections 3-3. GNDU Connections Safety Symbols The general definitions of safetysymbols used in this product note are listed below. WARNING The warning sign denotes a hazard. It calls attention to a procedure, practice, condition the like, which, if not crectly perfmed adhered to, could result in injury death to personnel. CAUTION The caution sign denotes a hazard. It calls attention to a procedure, practice, condition the like, which, if not crectly perfmed adhered to, could result in damage to destruction of part all of the product SMU Connections 3-5. VSU/VMU Connections 3-6. PGU Connections 3-7. Conclusion of Chapter 3 4. In Case Of Difficulty 4-1. SMU Oscillations due to Exceeding the Limits 4-2. Device Oscillations 4-3. Negative Resistance 4-4. Restrictions of Measurements Units 5. Appendix 5-1. Parts Infmation 2

3 1. Introduction This guide provides infmation on how to connect a prober to the HP 4155B/4156B Precision Semiconduct Parameter Analyzer. It also provides the necessary part numbers, and tips f making measurements. 2. General Infmation 2-1. Safety Precautions When you perfm measurements, always use a shielding box and an interlock circuit f safety Measurements should be perfmed in a shielding box in der: To prevent the operat from receiving an electric shock from the output voltage current of the HP 4155B/4156B. To minimize the effects of environmental noise and ambient light. Interlock circuit When you use a shielding box, you must install an interlock circuit. To prevent an operat from receiving an electric shock from high voltage (me than ± 40 V), connect the interlock (Intlk) terminal on the connect plate to a switch. The switch should turn on when the shielding box do is closed, and turn off when the shielding box access do is opened. (Refer to 3-2. Interlock Connections. ) 2-2. Low Current Measurement To reduce leakage current, you can use the guarding technique. Guarding Guarding reduces the leakage current between the measurement points and the instrument. This is imptant when you are measuring low current. Fig. 1 illustrates the they of guarding. The buffer amplifier (x1) keeps the potential of the GUARD conduct at the same potential as the FORCE conduct, so current does not flow between the FORCE and GUARD conducts. Therefe, the current measured by the SMU is the same as the current at the measurement point, because there is no leakage. F highly accurate measurements and minimal leakage, surround all FORCE lines from the SMU by a GUARD as far as possible. WARNING Do not touch the GUARD terminal with your bare hands, because of the danger of high voltage electrical shock. The potential of the GUARD terminal is equal to the output voltage. CAUTION Never connect the GUARD terminal to any other output, including CIRCUIT, FRAME GROUND, the GUARD terminal of any other unit. Doing so may damage the unit.. Use a grounded shielding box to minimize the effects of environmental noise and ambient light. To ground the shielding box, connect it to the chassis ground of the HP 4155B/4156B. Buffer GUARD FORCE Fig. 1 Guarding 3

4 2-3. Low Resistance Measurement To measure low resistance, connect the FORCE and SENSE terminals of the SMU to the using the shtest possible connection (F HRSMU and HPSMU only). When you measure a low resistance, high current flows through the. This high current increases the measurement err caused by the residual resistance of cables and contacts. To cancel the effect of this resistance, use Kelvin connections (4-wire) to extend the FORCE and SENSE lines separately to the. Kelvin connections Kelvin connections give good measurement results when you fce high current. Fig. 2 shows the equipment circuits f Kelvin and non-kelvin connections. of resistance R only. The impedance of the voltmeter is very high. Ideally, no current flows through rs1 and rs2, so the voltage drop across these resistances is negligible. Kelvin connections are effective even when fcing voltage. The voltage drop due to the residual resistance of the FORCE line wiring is fed back to the voltage source via a comparat in the SENSE line, thereby ensuring the specified voltage output at the sense point (where the FORCE and SENSE lines intersect). The input impedance of the comparat is high, so the current flow into the SENSE line is very low. Therefe, the output err is not significant if the SENSE line wiring has a residual resistance of 10 Ω less. With non-kelvin connections, the voltmeter measures the voltage drop of resistance rf1, R, and rf2. With Kelvin connections, the voltmeter measures the voltage drop rf1 rf1 rs1 rf2 R rs2 R rf2 (a) non-kelvin connection (b) Kelvin connection Fig. 2 Kelvin connection 4

5 2-4. Probe Usually, a prober will have probes consisting of a probe cable and needle. One side of the probe cable is connected to a probe needle. The other side is connected to the HP 4155B/4156B through the shielding box. HP recommends use of a full guarded needle, because nonguarded needles can cause leakage. Fig. 3 shows possible connections f a full guarded needle. The prober vend may let you select either triaxial coaxial connects. HP recommends using a triaxial connect to connect the SMU of the HP 4155B/4156B. To connect a triaxial connect to a coaxial connect of VSU/VMU/ PGU, use a triaxial - coaxial adapter ( ). (Refer to 5. Appendix.) If you have problems with these connections, you may want to solder them. HP provides two types of connect plates, a Connect Type and a Solder Type. Select the proper connection type f your prober. (Refer to 3-1. Installing the Connect Plate.) SMU Triaxial Cable VSU / VMU / PGU Coaxial Cable Direct FORCE (SENSE) GUARD If your probe doesn't have a probe cable, you may be able to use another recommended cable as a probe cable. (Refer to 5. Appendix.) When you use a probe card, these points are available. WARNING Be sure to use a shielding box and Intlk when you make a measurement. Do not use the adapters in Table 18 when the GUARD line connects to the outer conduct of the connect adapter. Because they connect GUARD line and outer conduct of the connect adapter, the potential of the GUARD terminal is equal to the output voltage and there is a potential f high voltage electrical shock at the adapter and connect. 3. Connecting to a This chapter provides infmation on connecting the prober. This infmation is f example only. If you need to know me about the connections between the connect plate and the prober, contact your prober vend. Probe Cable (triaxial) Probe WARNING Put inside a shielding box and use Intlk. The potential of this GUARD is equal to the output voltage. GUARD 3-1. Installing the Connect Plate Mount the HP 16495H/J connect plate on the side panel of your prober shielding box. One side of the plate is f connecting the cable from the HP 4155B/4156B. The other side of the plate is f connecting the cable to the prober. The HP 16495H/J have two options, Connect Type (opt. 001) and Solder Type (opt. 002). Use the Connect Type when the probe cable has a triaxial coaxial connect. Use the Solder Type when the probe cable has no connect, you have problems with the connection. Fig. 4 shows how to mount the connect plate. Table 1 and Fig. 5, Fig. 6, and Fig. 7 show me infmation about the connect plates. To install the connect plate, follow these steps. (1) Befe installing the connect plate, make sure that the HP 4155B/4156B and the HP 41501B are turned off. (2) Create the necessary openings and screw holes on your shielding box to match the connect plate. (3) Attach the connect plate with screws, nuts, and washers. (4) To prevent electric shock, make sure to install an interlock circuit. (Refer to 3-2. Interlock connections.) (5) Connect the cables between the HP 4155B/4156B and the connect plate. Use triaxial-coaxial adapter ( ) Recommended (full-guarded needle) FORCE Fig. 3 Probe Cable 5

6 The screws, nuts, and washers are not furnished. Each connect plate has four screw holes (3.2 mm in diameter). If you use a low noise probing system that has a built-in shield box, you may not need to install the connect plate and cables. This depends on the manufacturer. However, if the noise is not low enough, you will need to use a shielding box. If your prober has a connect assembly, you can connect cables to the connect plate of the shielding box through this connect assembly. When using this method, be aware of the limit of guard capacitance, and so on. (Refer to 4. In Case of Difficulty.) HP 4155B/4156B Option Opt. 301 Opt. 302 Opt. 311 Opt. 312 Table 1 Provided Connect Plates Stand-alone Product HP 16495H w / opt. 001 HP 16495H w / opt. 002 HP 16495J w / opt. 001 HP 16495J w / opt. 002 No. of Connects 6 x Triax / 6 x Coax / 1 x Intlk / 1 x GNDU 6 x Triax / 6 x Coax / 1 x Intlk / 1 x GNDU 8 x Triax / 4 x Coax / 1 x Intlk / 1 x GNDU 8 x Triax / 4 x Coax / 1 x Intlk / 1 x GNDU Connect Type (Front to Rear) Connect - Connect Connect - Solder Connect - Connect Connect - Solder Opening f Connect Plate Screw Washer Spring Washer Flat Screw Hole Nut Screw Connect Plate Screw Hole Nut Fig. 4 Mounting Connect Plate 6

7 GUARD FORCE (SENSE) Triaxial Connect (F SMU) Signal Line Coaxial Connect (F VS/VMU,PGU) SENSE Triaxial Connect (F GNDU) FORCE INTLK Terminal (a) Front View Triaxial Connect Ground Terminal Triaxial Connect Ground Terminal Common Terminal Common Terminal Coaxial Connect Coaxial Connect INTLK Terminal Triaxial Connect (F GNDU) INTLK Terminal Triaxial Connect (F GNDU) HP 16495H opt.001 HP 16495H opt.002 (The difference between the HP 16495H and J is the number of the Triax. and Coax. connects) (b) Rear View Fig. 5 Front View and Rear View of Connect Plate 7

8 Ø HP 16495H opt. 002 (Difference between the HP 16495H and J is the number of the Triax. and Coax. connects) Metal Cover Unit : mm Note : Metal cover is f preventing electrical shock. Metal cover is furnished with opt. 002 only. Fig. 6 Dimensions of the Connect Plate (HP 16495H/J) Triax. Coax. Triax. Coax. (a) Connect Type (opt. 001) (b) Solder Type (opt. 002) Fig. 7 Connection Type of Connect Plate ( Rear ) 8

9 3-2. Interlock Connections Fig. 8 (a) shows the interlock circuit needed f the shielding box, and Fig. 8 (b) and (c) show the pin assignments of the interlock connect on the connect plate. Interlock Cable Adapter If you already have an interlock circuit with a BNC coaxial connect, you can use an HP 16435A Interlock Cable Adapter. Switch and LED F dimensions of the switches and the LED, see Fig. 9, Fig. 10 and Fig. 11. F recommended parts, see table 2. First, install the switches to interlock the opening and closing of the do. F safety, use two switches in series. When me than ±40 V is fced from an SMU, the LED lights to indicate high voltage output. If the do of shielding box is open (the interlock terminals are open), the SMU cannot fce me than ±40 V. If the do is opened while the SMU output is me than ±40 V, the HP 4155B/4156B immediately drops the outputs of all units to 0 V. 12V HP 4155B/4156B 5V 10k Interlock Cable HP 16493J Opt m Opt.002 3m (a) Interlock circuit LED Interlock Switch Interlock open / close of the do Off : Do is open. On : Do is close. Conversely, if the do is closed (interlock terminals are shted), this function is disabled, and you can fce me than ±40 V. The connect plate and the HP 4155B/4156B have terminals f an interlock cable. To connect the interlock circuit, use an HP 16493J interlock cable. To prevent electric shock, make sure the interlock connection is as shown in Fig. 8. Interlock Switch LED (b) plug side view of Intlk terminal (c) wiring side view of Intlk terminal Fig. 8 Interlock Circuit Ø 6 WARNING Dangerous voltages of up to the maximum voltage of SMUs may be present at the FORCE, GUARD, and SENSE terminal when the interlock terminals are shted Cathode(-) Anode(+) 5 Ø 5 Ø 5.6 Units: mm Fig. 9 Dimensions of LED 9

10 Switch off Switch on 15.2 Max NC NC 2.8 Ø Units: mm Ø 3.1 COM Fig. 10 Dimensions of Interlock Switch ( ) Switch off Switch on Ø Units: mm Fig. 11 Dimensions of Interlock Switch ( ) Table 2 Parts Infmation Interlock Cable - 1.5m 1 - HP16493J 001 Interlock Cable - 3.0m 1 - HP16493J 002 Interlock Cable Adapter 1 - HP16435A - Switch Switch LED (VF ~= IF = 10mA)

11 3-3. GNDU Connections An SMU has FORCE (SENSE), GUARD, and, but a GNDU has SENSE, FORCE, and as shown in Fig. 12. A GNDU terminal has no GUARD line. When you connect it, pay attention to this connection. Triaxial Cable HP 16493H Opt m Opt m Apadter f GNDU Probe Cable (Triaxial) SENSE Connect Plate HP16495H Opt. 001 HP16495J Opt. 001 FORCE Fig. 12 GNDU Terminal CAUTION Do not use the HP 16493C triaxial cable f an SMU to connect the GNDU to a. The GNDU can sink up to 1.6 A, and the maximum current rating f that cable is 1 A. Use an HP 16493H triaxial cable f a GNDU. When you connect to the prober, be sure to connect the FORCE line to the probe. Current flows only in the FORCE line, not the SENSE line. (Connect Type) Connect the triaxial connect using an adapter f GNDU ( ) as shown in Fig. 13. F this part, see Table 18 in 5. Appendix. F parts infmation, see Table 3. (Solder Type) Solder the SENSE line, and sht SENSE and FORCE as shown in Fig. 14. To connect the GNDU quickly f measurements where accuracy is not imptant, connect to the prober without shting SENSE and FORCE. F parts infmation, see Table 4. Fig. 13 Example of a GNDU non-kelvin Connection (Connect Plate Type: connect) Table 3 Parts Infmation Triaxial Cable -1.5m 1 - HP16493H 001 Triaxial Cable -3.0m 1 - HP16493H 002 Connect Plate (Connect Type) 1 - HP16495H 001 Connect Plate (Connect Type) 1 - HP16495J 001 Adapter f GNDU (triaxial (m) - triaxial (f)) Triaxial Cable HP 16493H Opt m Opt m Connect Plate HP16495H Opt. 002 HP16495J Opt. 002 Insulat FORCE SENSE Probe Cable (Coaxial) FORCE Line SENSE Line Fig. 14 Example of a GNDU non-kelvin Connection (Connect Plate Type: solder) Table 4 Parts Infmation Triaxial Cable -1.5m 1 - HP16493H 001 Triaxial Cable -3.0m 1 - HP16493H 002 Connect Plate (Solder Type) 1 - HP16495H 002 Connect Plate (Solder Type) 1 - HP16495J

12 3-4. SMU Connections An SMU terminal is shown in Fig. 15. GUARD (1) Kelvin connections These instructions apply when all connections are Kelvin. Two probes must contact the wafer in this connection. Connect an HP 16493K Kelvin triaxial cable ( two HP 16493C triaxial cables) between the SMU and the connect plate. Connect the FORCE and SENSE lines to probes separately. (Only f HRSMU and HPSMU) (Connect Type) Connect the triaxial connect on the probe cable as shown in Fig. 16. To prevent oscillations, use sht cables. (Refer to 4. In Case of Difficulty.) F parts infmation, see Table 5. (Solder Type) Fig. 15 SMU Terminal FORCE (SENSE) Solder the FORCE line, SENSE line, and GUARD line as shown in Fig. 17. If the probe cable is triaxial, also solder the line. To prevent oscillations, use sht cables. (Refer to 4. In Case of Difficulty.) F parts infmation, see Table 6. Kelvin Triaxial Cable HP 16493K Opt m Opt.002 3m Connect Plate HP16495H Opt. 001 HP16495J Opt. 001 Probe Cable (Triaxial) Probe Cable (Triaxial) Fig. 16 Example of an SMU Kelvin Connection (Connect Plate Type: connect) Table 5 Parts Infmation Kelvin Triaxial Cable -1.5m 1 - HP16493K 001 Kelvin Triaxial Cable -3.0m 1 - HP16493K 002 Triaxial Cable -1.5m 1 - HP16493C 001 Triaxial Cable -3.0m 1 - HP16493C 002 Connect Plate (Connect Type) 1 - HP16495H 001 Connect Plate (Connect Type) 1 - HP16495J 001 Kelvin Triaxial Cable HP 16493K Opt m Opt.002 3m Connect Plate HP16495H Opt. 002 HP16495J Opt. 002 GUARD FORCE SENSE GUARD Insulat Probe Cable (Coaxial) Probe Cable (Coaxial) Fig. 17 Example of an SMU Kelvin Connection (Connect Plate Type: solder) Table 6 Parts Infmation GUARD Line FORCE,SENSE Line Kelvin Triaxial Cable -1.5m 1 - HP16493K 001 Kelvin Triaxial Cable -3.0m 1 - HP16493K 002 Triaxial Cable -1.5m 1 - HP16493C 001 Triaxial Cable -3.0m 1 - HP16493C 002 Connect Plate (Solder Type) 1 - HP16495H 002 Connect Plate (Solder Type) 1 - HP16495J

13 (2) Kelvin to non-kelvin These instructions apply when the connections up to the Connect Plate are Kelvin, but the probe is a non-kelvin connection. Connect an HP 16493K Kelvin triaxial cable ( two HP 16493C triaxial cables) between the SMU and the Connect plate. (Only f HRSMU and HPSMU) Kelvin Triaxial Cable HP 16493K Opt m Opt.002 3m Connect Plate HP16495H Opt. 001 HP16495J Opt. 001 Triaxial Cable m Probe Cable (Triaxial) Tee Triaxial BNC Unusable Note: Connect the cable and tee connect as shown. Due to space restrictions an adjacent connect is unusable. Since three connects are necessary f a Kelvin connection a connect plate must be used. Select the crect connect plate f your application. To make two Kelvin connections, use an HP 16495H. To make three Kelvin connections, use an HP 16495J. (Connect Type) Connect the triaxial connect on the probe cable as shown in Fig. 18. Connect the FORCE and SENSE lines on this side of the probe input terminal. A Tee Triaxial BNC adapter can be used. F parts infmation, see Table 7. Note: When connecting the cable and tee connect as shown in Fig 18, space restrictions make an adjacent connect unusable. Since three connects are necessary f a Kelvin connection a connect plate must be used. Select the crect connect plate f your application. To make two Kelvin connections, use an HP 16495H. To make three Kelvin connections, use an HP 16495J. (Solder Type) Connect the FORCE and SENSE lines on this side of the probe input terminal. Solder the FORCE line and the GUARD line, and sht FORCE and SENSE as shown in Fig. 19. If the probe cable is triaxial, also solder the line. F parts infmation, see Table 8. Fig. 18 Example of an SMU Kelvin - non-kelvin Connection (Connect Plate Type: connect) Table 7 Parts Infmation Kelvin Triaxial Cable -1.5m 1 - HP16493K 001 Kelvin Triaxial Cable -3.0m 1 - HP16493K 002 Triaxial Cable -0.4m Triaxial Cable -1.5m 1 - HP16493C 001 Triaxial Cable -3.0m 1 - HP16493C 002 Tee Triaxial BNC Connect Plate (Connect Type) 1 - HP16495H 001 Connect Plate (Connect Type) 1 - HP16495J 001 Connect Plate HP16495H Opt. 002 HP16495J Opt. 002 SENSE GUARD Insulat GUARD Line Kelvin Triaxial Cable FORCE,SENSE Line HP 16493K GUARD Opt m FORCE Opt.002 3m Probe Cable (Coaxial) Fig. 19 Example of an SMU Kelvin - non-kelvin Connection (Connect Plate Type: solder) Table 8 Parts Infmation Kelvin Triaxial Cable -1.5m 1 - HP16493K 001 Kelvin Triaxial Cable -3.0m 1 - HP16493K 002 Triaxial Cable -1.5m 1 - HP16493C 001 Triaxial Cable -3.0m 1 - HP16493C 002 Connect Plate (Solder Type) 1 - HP16495H 002 Connect Plate (Solder Type) 1 - HP16495J

14 (3) non-kelvin to non-kelvin These instructions apply when all connections are non-kelvin. Connect the HP 16493C triaxial cables between the SMU and the Connect plate. FORCE Triaxial Cable HP 16493C Opt m Opt.002 3m Probe Cable (Triaxial) (Connect Type) Connect the triaxial connect on the probe cable as shown in Fig. 20. F parts infmation, see Table 9. (Solder Type) Solder the FORCE line and the GUARD line as shown in Fig. 21. If the probe cable is triaxial, also solder the line. F parts infmation, see Table 10. SENSE Connect Plate HP16495H Opt. 001 HP16495J Opt. 001 Fig. 20 Example of an SMU non-kelvin - non-kelvin Connection (Connect Plate Type: connect) Table 9 Parts Infmation Triaxial Cable -1.5m 1 - HP16493C 001 Triaxial Cable -3.0m 1 - HP16493C 002 Connect Plate (Connect Type) 1 - HP16495H 001 Connect Plate (Connect Type) 1 - HP16495J 001 Triaxial Cable HP 16493C Opt m Opt.002 3m Insulat GUARD FORCE Probe Cable (Coaxial) GUARD Line FORCE,SENSE Line FORCE SENSE Connect Plate HP16495H Opt. 002 HP16495J Opt. 002 Fig. 21 Example of an SMU non-kelvin - non-kelvin Connection (Connect Plate Type: solder) Table 10 Parts Infmation Triaxial Cable -1.5m 1 - HP16493C 001 Triaxial Cable -3.0m 1 - HP16493C 002 Connect Plate (Solder Type) 1 - HP16495H 002 Connect Plate (Solder Type) 1 - HP16495J

15 3-5. VSU/VMU Connections A VSU/VMU terminal is shown in Fig. 22. Signal Line BNC Coaxia Cable HP 16493B Opt m Opt.002 3m Probe Cable (Coaxial) Fig. 22 VSU/VMU Terminal Connect Plate HP16495H Opt. 001 HP16495J Opt. 001 Connect the HP 16493B coaxial cable between the VSU/VMU and the connect plate. (Connect Type) Connect the coaxial connect on the probe cable as shown in Fig. 23. If the probe cable is triaxial, use a triaxial - coaxial adapter ( ). F parts infmation, see Table 11. (Solder Type) Fig. 23 Example of a VSU/VMU Connection (Connect Plate Type: connect) Table 11 Parts Infmation Coaxial Cable -1.5m 1 - HP16493B 001 Coaxial Cable -3.0m 1 - HP16493B 002 Connect Plate (Connect Type) 1 - HP16495H 001 Connect Plate (Connect Type) 1 - HP16495J 001 Triaxial(f) - Coaxial(m) Adapter BNC Coaxia Cable HP 16493B Opt m Opt.002 3m Insulat Signal Line Probe Cable (Coaxial) Solder the signal line as shown in Fig. 24. F parts infmation, see Table 12. Connect Plate HP16495H Opt. 002 HP16495J Opt. 002 Fig. 24 Example of a VSU/VMU Connection (Connect Plate Type: solder) Table 12 Parts Infmation Coaxial Cable -1.5m 1 - HP16493B 001 Coaxial Cable -3.0m 1 - HP16493B 002 Connect Plate (Solder Type) 1 - HP16495H 002 Connect Plate (Solder Type) 1 - HP16495J

16 3-6. PGU Connections A PGU terminal is shown in Fig. 25. BNC Coaxia Cable HP 16493B Opt m Opt.002 3m Probe Cable (Coaxial) Signal Line Fig. 25 PGU Terminal Connect the HP 16493B coaxial cable between the PGU and the Connect plate. Connect Plate HP16495H Opt. 001 HP16495J Opt. 001 Fig. 26 Example of a PGU Connection (Connect Plate Type: connect) Table 13 Parts Infmation (Connect Type) Connect the coaxial connect on the probe cable as shown in Fig. 26. If the probe cable is triaxial, use a triaxial - coaxial adapter ( ). F parts infmation, see Table 13. (Solder Type) Solder the Signal line and COM- MON as shown in Fig. 27. Coaxial Cable -1.5m 1 - HP16493B 001 Coaxial Cable -3.0m 1 - HP16493B 002 Connect Plate (Connect Type) 1 - HP16495H 001 Connect Plate (Connect Type) 1 - HP16495J 001 Triaxial(f) - Coaxial(m) Adapter BNC Coaxia Cable HP 16493B Opt m Opt.002 3m Insulat Signal Line Probe Cable (Coaxial) F parts infmation, see Table 14. Connect Plate HP16495H Opt. 002 HP16495J Opt. 002 Fig. 27 Example of a PGU Connection (Connect Plate Type: solder) Table 14 Parts Infmation Coaxial Cable -1.5m 1 - HP16493B 001 Coaxial Cable -3.0m 1 - HP16493B 002 Connect Plate (Solder Type) 1 - HP16495H 002 Connect Plate (Solder Type) 1 - HP16495J

17 3-7. Conclusion of Chapter 3 You can connect a prober to the HP 4155B/4156B using the previous instructions and examples. When making the connections, remember these points: (1) Befe making a measurement, confirm that the shielding box and interlock circuit are in place f safety and lowering noise effects. Mount connect plates in the shielding box as needed. (2) Use Kelvin connections when you measure low resistance (high current). (3) Use guarding (f example, a full guarded needle) when you measure low current. (4) Cables must be sht and stable f accurate measurement. The prober documentation may show different methods of connection. The connections described here are only examples. Fig. 28 shows the prober setup. Cables must be sht and stable f accurate measurement. To Measurement Unit Interlock Connect Plate Probe To Interlock Switches and LED Ground the shield box by connecting with the chassis of HP 4155B/4156B. (In Fig. 28, the shield box is connected to the ground through the connect plate.) Fig. 28 Example Cabling to 17

18 4. In Case Of Difficulty 4-1. SMU Oscillations due to Exceeding the Limits The HP 4155B/4156B have low current fcing and measurement capability through their SMUs. An SMU uses a feedback circuit to maintain very high stability of current / voltage sourcing. Therefe, the guard capacitance (a load f SMUs) of all connections to the SMU must be within certain limits to prevent SMU circuit oscillation. Select the proper cable type and length to keep guard capacitance low. F SMU limits, refer to 4-3. Restriction of Measurement Units Device Oscillations Ferrite Beads Test Device Fig. 29 Example of Ferrite 4-3. Negative Resistance If the has negative resistance characteristics as shown in Fig. 30 (b) and (d), the SMUs may oscillate, because SMUs operate as negative feedback amplifiers. To solve this problem: F a voltage-controlled negative resistance device: Connect G in parallel with the to cancel negative resistance as shown in Fig. 30 (a). To obtain an output I-V curve, use the following equation. Iy = I - G V F current-controlled negative resistance device: Connect R in series with the to cancel negative resistance as shown in Fig. 30 (c). To obtain an output I-V curve, use the following equation. Vz = V - R I If the resistance of the is less than 1 MΩ, you can use an R-Box. When measuring parameters of high-frequency devices, such as GaAs MESFETs high-frequency bipolar transists, oscillation may cause measurement problems. I V G Iy To solve this problem: F FETs, add resistive ferrite beads as close as possible to the gate. F bipolar transists, add resistive ferrite beads ( ) as close as possible to the base emitter, as shown in Fig. 29. I (a) F voltage-controlled negative Vz (b) Keep cables as sht as possible. Long cables cause oscillation because of their large inductance. (c) R (d) F current-controlled negative Fig. 30 Negative Resistance 18

19 4-4. Restrictions of Measurement Units The conditions in Table 15 are required f Measurement Units to measure accurately. (If the capacitance exceeds the limits, Measurements Units cannot measure accurately because of the SMU's oscillations.) Because high cable resistance causes an err in the feedback circuit of the SMUs, keep cables as sht as possible. This is especially imptant when making high current measurements. F me infmation on cables, see Table 16 and Table 17. Unit Maximum Capacitive Load Maximum GUARD Capacitance Maximum Shield Capacitance HRSMU 1000pF 900pF 5000pF Table 15 Restrictions of Measurement Units Cable Resistance Maximum allowable cable resistance when using Kelvin connections 10W (FORCE,SENSE) Typical Voltage Source Output Resistance FORCE line/ non-kelvin connection 0.2W MPSMU 1000pF 900pF 5000pF - Max. 0.3W Maximum allowable cable resistance when using Kelvin FORCE line/ non-kelvin connection HPSMU 1000pF 900pF 5000pF connections 0.2W FORCE: 0.7W (100mA to 1A) FORCE: 10W (<100mA) SENSE: 10W VSU 10uF GNDU <1uF - - FORCE: <1W - SENSE: <10W GUARD capacitance: Capacitance between FORCE (SENSE) and GUARD line Shield capacitance: Capacitance between GUARD and line 19

20 Table 16 Cable Reference Data PRODUCT OPT DESCRIPTION LENGTH CAPACITANCE RESISTANCE HP 16493B HP 16493C HP 16493H HP 16493K 001 BNC cable 1.5m 160pF 002 BNC cable 3.0m 330pF 001 SMU triaxial cable 1.5m 002 SMU triaxial cable 3.0m 001 GNDU triaxial cable 1.5m 002 GNDU triaxial cable 3.0m 001 Kelvin triaxial cable 1.5m 002 Kelvin triaxial cable 3.0m GUARD capacitance: 120pF Capacitance between GUARD and line: 900pF GUARD capacitance: 240pF Capacitance between GUARD and line: 1800pF Capacitance between FORCE and line: 550pF Capacitance between FORCE and SENSE line: 350pF Capacitance between FORCE and line: 1100pF Capacitance between FORCE and SENSE line: 700pF GUARD capacitance: 140pF GUARD capacitance: 260pF Resistance of FORCE line 220mW Resistance of FORCE line 400mW Resistance of FORCE line 160mW Resistance of FORCE line 320mW Resistance of FORCE line 80mW Resistance of FORCE line 150mW Resistance of FORCE line 170mW Resistance of FORCE line 340mW MAXIMUM CURRENT 1A 1A 1A 1A 1.6A 1.6A 1A 1A Table 17 Cable Reference Data PART-NUMBER DESCRIPTION CAPACITANCE RESISTANCE Coaxial cable 77pF/m Low-noise coaxial cable 130pF/m Coaxial cable 102pF/m Resistance of center conduct: 133mW/m maximum Resistance of center conduct: 114mW/m maximum Resistance of center conduct: 139mW/m maximum DIELECTRIC WITHSTAND VOLTAGE TEST JACKET EXTERNAL DIAMETER VOLTAGE RATING COLOR 500Vrms, 1minute 3.0mm Vrms, 1minute 2.7mm Vrms, 1minute 3.0mm AWG22 insulated wire (0.634mm in diameter) - 56mW/m V Black AWG24 insulated wire (0.511mm in diameter) - 89mW/m V Black AWG24 insulated wire (0.511mm in diameter) - 89mW/m V Brown AWG24 insulated wire (0.511mm in diameter) - 89mW/m V Red AWG24 insulated wire (0.511mm in diameter) - 89mW/m V Yellow 20

21 5. Appendix 5-1. Parts Infmation (1) Adapter Infmation If you need to make a connection between a triaxial connect and a coaxial connect, use a triaxial - coaxial adapter. Table 18 shows the adapter infmation provided by HP. If you need an adapter which is not provided, contact a local parts vend. WARNING Be sure to use a shielding box and Intlk when you make a measurement. Do not use the adapters in Table 18 when the GUARD line connects to the outer conduct of the connect adapter. Because they connect GUARD line and outer conduct of the connect adapter, the potential of the GUARD terminal is equal to the output voltage and there is a potential f high voltage electrical shock at the adapter and connect. Table 18 Adapter Infmation DESCRIPTION QTY PART-NUMBER ILLUSTRATION Triaxial(m) - Coaxial(f) Triaxial(f) - Coaxial(m) Triaxial(f) - Coaxial(f) Triaxial(m) - Coaxial(f) Triaxial(f) - Coaxial(m) Triaxial(f) - Coaxial(m) Triaxial(m) - Coaxial(f) Triaxial(m) - Triaxial(f) (f GNDU) Table 19 Cables Infmation Coaxial Cable f GNDU Low-noise Coaxial Cable f SMU and PGU (with select) Coaxial Cable f PGU AWG 22 Insulated Wire f GNDU (Black) AWG 24 Insulated Wire f VS/VMU (Black) AWG 24 Insulated Wire f VS/VMU (Red) AWG 24 Insulated Wire f VS/VMU (Yellow) AWG 24 Insulated Wire f VS/VMU (Brown) (2) Cable Infmation If your probe has no probe cable, you can use other recommended cables. Table 19 shows the recommended cables. If you use a PGU with an HP 16440A select, use a low-noise coaxial cable ( ). Table 20 Parts Infmation Screw Spring Washer Terminal Washer Nut (3) Other Parts If you need parts to fix a connect plate, see Table 20. Order the quantity you need. (The number of holes in a connect plate is four.) If you need ferrite beads f preventing oscillation, see Table 21. Table 21 Parts Infmation Ferrite Beads

22 F me infmation about Hewlett- Packard test and measurement products, applications, services, and f a current sales office listing, visit our web site: You can also contact one of the following centers and ask f a test and measurement sales representative. United States: Hewlett-Packard Company Test and Measurement Call Center P.O. Box 4026 Englewood, CO (tel) Canada: Hewlett-Packard Canada Ltd Spectrum Way Mississauga, Ontario L4W 5G1 (tel) (905) Europe: Hewlett-Packard Company European Marketing Centre P.O. Box AZ Amstelveen The Netherlands (tel) (31 20) Japan: Hewlett-Packard Japan Ltd. Measurement Assistance Center 9-1, Takakura-Cho, Hachioji-Shi, Tokyo 192, Japan (tel) (81) (fax) (81) Latin America: Hewlett-Packard Company Latin American Region Headquarters 5200 Blue Lagoon Drive 9th Flo Miami, Flida U.S.A. (tel) (305) /4220 (fax) (305) Australia/New Zealand: Hewlett-Packard Australia Ltd Joseph Street Blackburn, Victia 3130 Australia (tel) (Australia) (tel) (New Zealand) (fax) (61 3) Asia Pacific: Hewlett-Packard Asia Pacific Ltd 17-21/F Shell Tower, Times Square, 1 Matheson Street, Causeway Bay, Hong Kong (tel) (852) (fax) (852) Hewlett-Packard Company 1998 Data subject to change Printed in Japan 02/ E 22

Wide Range DC Current Biased Inductance Measurement. Application Note with HP 4284A Precision LCR Meter / HP 42841A Bias Current Source

Wide Range DC Current Biased Inductance Measurement. Application Note with HP 4284A Precision LCR Meter / HP 42841A Bias Current Source H Wide Range DC Current Biased Inductance Measurement Application Note 369-8 with HP 4284A Precision LCR Meter / HP 42841A Bias Current Source INTRODUCTION A large number of switching power supply inductors

More information

Permittivity Measurements of PC Board and Substrate Materials using the HP 4291B and HP 16453A

Permittivity Measurements of PC Board and Substrate Materials using the HP 4291B and HP 16453A This literature was published years prior to the establishment of Agilent Technologies as a company independent from Hewlett-Packard and describes products or services now available through Agilent. It

More information

Keysight Technologies Parametric Instrument Accessories

Keysight Technologies Parametric Instrument Accessories Keysight Technologies Parametric Instrument Accessies Accessies Guide Technical Overview Table of Contents 1. Introduction... 3 2. Connecting to Fixture... 4 2.1. Jumper cables... 4 2.2. ocket modules...

More information

HP 8491A/B, 8492A, 8493A/B/C, 11581A, 11582A and 11583A/C Coaxial Attenuators. Product Overview

HP 8491A/B, 8492A, 8493A/B/C, 11581A, 11582A and 11583A/C Coaxial Attenuators. Product Overview HP 8491A/B, 8492A, 8493A/B/C, 11581A, 11582A and 11583A/C Coaxial Attenuators Product Overview dc to 26.5 GHz HP 8491A/B HP 8492A HP 8493A/B HP 8493C High accuracy Low SWR Broadband frequency coverage

More information

6.5-Digit Multimeter, High- Accuracy, C-Size HP E1410A Technical Specifications

6.5-Digit Multimeter, High- Accuracy, C-Size HP E1410A Technical Specifications PDFINFO H 5 5 6 1-0 1 6.5-Digit Multimeter, High- Accuracy, C-Size Technical Specifications 1-Slot, C-size, message based Vdc/ac, 2- & 4-wire Ω Noise rejection with long integration times/ guarding Quality

More information

HP 8921A Cell Site Test Set. Product Note AMPS Base Station Testing

HP 8921A Cell Site Test Set. Product Note AMPS Base Station Testing HP 8921A Cell Site Test Set Product Note 8921-1 AMPS Base Station Testing AMPS Base Station Testing This product note describes manual operation of the HP 8921A Cell Site Test Set (or HP 8920A RF Communications

More information

Optimizing Electronic Component and Material Impedance Measurements

Optimizing Electronic Component and Material Impedance Measurements H Optimizing Electronic Component and Material Impedance Measurements Application Note 369-1 Taking Full Advantage of The HP 4284A Precision LCR Meter's Versatility & Deve lopment Production Research I

More information

HP 8560 E-Series Spectrum Analyzers Technical Specifications

HP 8560 E-Series Spectrum Analyzers Technical Specifications HP 8560 E-Series Spectrum Analyzers Technical Specifications HP 8560E 30 Hz to 2.9 GHz HP 8561E 30 Hz to 6.5 GHz HP 8562E 30 Hz to 13.2 GHz HP 8563E 30 Hz to 26.5 GHz HP 8564E 30 Hz to 40 GHz HP 8565E

More information

Hints. for making. Better. Spectrum Analyzer. Measurements. Application Note

Hints. for making. Better. Spectrum Analyzer. Measurements. Application Note Hints for making Better Spectrum Analyzer Measurements Application Note 1286-1 The Heterodyne Spectrum Analyzer The spectrum analyzer, like an oscilloscope, is a basic tool used for observing signals.

More information

HP 8509B Lightwave Polarization Analyzer. Product Overview. Optical polarization measurements of signal and components nm to 1600 nm

HP 8509B Lightwave Polarization Analyzer. Product Overview. Optical polarization measurements of signal and components nm to 1600 nm HP 8509B Lightwave Polarization Analyzer Product Overview polarization measurements of signal and components 1200 nm to 1600 nm 2 The HP 8509B Lightwave Polarization Analyzer The HP 8509B lightwave polarization

More information

profile New Generation Precision Impedance Analyzer for functionality and efficiency in engineering 40 Hz to 110 MHz 4294A

profile New Generation Precision Impedance Analyzer for functionality and efficiency in engineering 40 Hz to 110 MHz 4294A profile HP 4294A Precision Impedance Analyzer H New Generation Precision Impedance Analyzer for functionality and efficiency in engineering 40 Hz to 110 MHz 1 HP 4294A Precision Impedance Analyzer, NEW

More information

product note Using Power Leveling to Control Test Port Output Power Product Note 8510XF XF Network Analyzer

product note Using Power Leveling to Control Test Port Output Power Product Note 8510XF XF Network Analyzer This literature was published years prior to the establishment of Agilent Technologies as a company independent from Hewlett-Packard and describes products or services now available through Agilent. It

More information

HP 8901A Modulation Analyzer 150 khz to 1300 MHz Product Overview Measurements* Frequency Range: 150 khz to 1300 MHz Resolution: 10 Hz below 1000 MHz, 100 Hz above 1000 MHz Input Level: Automatic Mode:

More information

Introduction to BER testing of WDM systems

Introduction to BER testing of WDM systems Introduction to BER testing of WDM systems Application note 1299 Wavelength division multiplexing (WDM) is a new and exciting technology for migrating the core optical transmission network to higher bandwidths.

More information

Agilent 4072A Advanced Parametric Test System with Agilent SPECS

Agilent 4072A Advanced Parametric Test System with Agilent SPECS Agilent 4072A Advanced Parametric Test System with Agilent SPECS Technical Data 1. General Description The Agilent 4072A Advanced Parametric Test System is designed to perform precision DC measurement,

More information

HP 4286A RF LCR Meter. Technical Specifications. Specifications. Test Signal

HP 4286A RF LCR Meter. Technical Specifications. Specifications. Test Signal HP 4286A RF LCR Meter Technical Specifications Specifications Specifications describe the instrument's warranted performance over the temperature range of 0 C to 55 C (except as noted). Supplemental characteristics

More information

Better. Hints. Microwave Counter. for making. Measurements

Better. Hints. Microwave Counter. for making. Measurements This literature was published years prior to the establishment of Agilent Technologies as a company independent from Hewlett-Packard and describes products or services now available through Agilent. It

More information

Keysight 16440A SMU/Pulse Generator Selector

Keysight 16440A SMU/Pulse Generator Selector Keysight 16440A SMU/Pulse Generator Selector User s Guide Notices Keysight Technologies 1994-2014 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

E-series E9300 Average Power Sensor Specifications

E-series E9300 Average Power Sensor Specifications E-series E9300 Average Power Sensor Specifications The E-series E9300 wide dynamic range, average power sensors are designed for use with the EPM family of power meters. These specifications are valid

More information

Network, Spectrum, and Impedance Evaluation of Electronic Circuits and Components

Network, Spectrum, and Impedance Evaluation of Electronic Circuits and Components H Network, Spectrum, and Impedance Evaluation of Electronic Circuits and Components Application Note 1308-1 HP 4395A/HP 4396B Network/Spectrum/Impedance Analyzer 1 Introduction With the current trends

More information

product overview HP 8970 Series Noise Figure Measurement Products

product overview HP 8970 Series Noise Figure Measurement Products product overview HP 8970 Series Noise Figure Measurement Products Accurate and Complete Noise Figure Measurement Solutions 2 Whether measuring at RF or microwave frequencies, Hewlett Packard offers you

More information

Welcome! Device Characterization with the Keithley Model 4200-SCS Characterization System.

Welcome! Device Characterization with the Keithley Model 4200-SCS Characterization System. Welcome! Device Characterization with the Keithley Model 4200-SCS Characterization System Safety Precautions Working with Electricity Before starting, check cables for cracks or wear. Get new cables if

More information

HP 8647A and 8648A/B/C/D Signal Generators Technical Specifications

HP 8647A and 8648A/B/C/D Signal Generators Technical Specifications and 8648A/B/C/D Signal Generators Technical Specifications, 250 khz to 1 GHz HP 8648A, 100 khz to 1 GHz HP 8648B, 9 khz to 2 GHz HP 8648C, 9 khz to 3.2 GHz HP 8648D, 9 khz to 4 GHz FREQUENCY MODULATION

More information

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents Model 0-MMPC-L Keithley Instruments, Inc. Multi-measurement Prober Cable Kit 877 Aurora Road Quick Start Guide Cleveland, Ohio 9-888-KEITHLEY http://www.keithley.com Overview The Keithley Instruments Model

More information

User s Guide. Agilent 16441A R-Box. Agilent Part No Printed in Japan January Edition 4

User s Guide. Agilent 16441A R-Box. Agilent Part No Printed in Japan January Edition 4 User s Guide Agilent 16441A R-Box Agilent Part No. 16441-90000 Printed in Japan January 2000 Edition 4 Legal Notice The information contained in this document is subject to change without notice. Copyright

More information

Keysight 16065A EXT Voltage Bias Fixture

Keysight 16065A EXT Voltage Bias Fixture Keysight 16065A EXT Voltage Bias Fixture Operation and Service Manual 1 Notices The information contained in this document is subject to change without notice. This document contains proprietary information

More information

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview Model 4210-MMPC-W Keithley Instruments, Inc. Multi-measurement Prober Cable Kit 28775 urora Road Quick Start Guide Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Overview The Keithley Instruments

More information

Fundamentals of Microwave Frequency Counters. Application Note Electronic Counters Series

Fundamentals of Microwave Frequency Counters. Application Note Electronic Counters Series H Fundamentals of Microwave Frequency Counters Application Note 200-1 Electronic Counters Series 1 Table of Contents Down-Conversion Techniques for Automatic Microwave Frequency Counters... 3 Prescaling...

More information

Agilent 4070 Series Accurate Capacitance Characterization at the Wafer Level

Agilent 4070 Series Accurate Capacitance Characterization at the Wafer Level Agilent 4070 Series Accurate Capacitance Characterization at the Wafer Level Application Note 4070-2 Agilent 4070 Series Semiconductor Parametric Tester Introduction The continuing trend of decreasing

More information

ProBER 2 2 Mb/s Handheld Test Set. The handheld that takes 2 Mb/s testing beyond convention

ProBER 2 2 Mb/s Handheld Test Set. The handheld that takes 2 Mb/s testing beyond convention ProBER 2 2 Mb/s Handheld Test Set The handheld that takes 2 Mb/s testing beyond convention 1 2 Mb/s BER and signal quality measurements in a handheld The ProBER 2 test set provides a powerful handheld

More information

200 V channels 1-3 Common LO channel Maximum DCV Both 3030 V 202 V 40 V 42 V Maximum DCI 1. DC 122 ma A 4.5 A AC + DC 100 µa 100 µa

200 V channels 1-3 Common LO channel Maximum DCV Both 3030 V 202 V 40 V 42 V Maximum DCI 1. DC 122 ma A 4.5 A AC + DC 100 µa 100 µa Model 8020 Keithley Instruments High Power Interface Panel 28775 Aurora Road Instrument Specifications Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley SPECIFICATION CONDITIONS The Model

More information

MARTINDALE INSTRUCTIONS. E-ZeTest EZ2500 LOOP TESTER ELECTRIC. Trusted by professionals. Other products from Martindale:

MARTINDALE INSTRUCTIONS. E-ZeTest EZ2500 LOOP TESTER ELECTRIC. Trusted by professionals. Other products from Martindale: Other products from Martindale: 17th Edition Testers All-in-one s Calibration Equipment Continuity Testers Electrician s kits Full Calibration & Repair Service Fuse Finders Digital Clamp Meters Digital

More information

User s Guide Volume 2. Measurement and Analysis

User s Guide Volume 2. Measurement and Analysis User s Guide Volume 2 Measurement and Analysis Agilent 4155B Semiconductor Parameter Analyzer Agilent 4156B Precision Semiconductor Parameter Analyzer Agilent Part No. 04156-90200 Printed in Japan May

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OPERATING MANUAL 300 WATT ELECTRONIC LOAD MODULE Agilent Model 60502B FOR MODULES WITH SERIAL NUMBERS: 3118A-00101 AND

More information

CDPD Conceptual Overview. Product Note

CDPD Conceptual Overview. Product Note CDPD Conceptual Overview Product Note Cellular Digital Packet Data (CDPD) is a system in which a robust packet data service can be added to existing Advanced Mobile Phone System (AMPS) cellular voice systems

More information

Agilent 16193A Small Side Electrode SMD Test Fixture Operation and Service Manual

Agilent 16193A Small Side Electrode SMD Test Fixture Operation and Service Manual Agilent 16193A Small Side Electrode SMD Test Fixture Operation and Service Manual Agilent 16193A Small Side Electrode SMD Test Fixture Operation and Service Manual Agilent Part No. 16193-90040 Printed

More information

4082A Parametric Test System Keysight 4080 Series

4082A Parametric Test System Keysight 4080 Series 4082A Parametric Test System Keysight 4080 Series Leading-edge technologies demand high performance semiconductor devices available at the lower cost-of-test in high volume manufacturing. Keysight offers

More information

Measuring CNT FETs and CNT SETs Using the Agilent B1500A

Measuring CNT FETs and CNT SETs Using the Agilent B1500A Measuring CNT FETs and CNT SETs Using the Agilent B1500A Application Note B1500-1 Agilent B1500A Semiconductor Device Analyzer Introduction Exotic carbon nanotube (CNT) structures have generated a great

More information

WARNING. 5 Mounting. 1 CE marking. 2 Confirmation of packed content. 3 Safe use of laser product. 4 Part description. Instruction Manual

WARNING. 5 Mounting. 1 CE marking. 2 Confirmation of packed content. 3 Safe use of laser product. 4 Part description. Instruction Manual Instruction Manual Micro Laser Sens (CMOS) HG-C Series ME-HGC000VEN Thank you very much f purchasing Panasonic products. Please read this Instruction Manual carefully and thoughly f the crect and optimum

More information

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level Keysight Technologies Accurate Capacitance Characterization at the Wafer Level 4080 Series Parametric Test Systems Application Note Introduction The continuing trend of decreasing device geometries of

More information

PET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F

PET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F Water Cooled Triode For Industrial RF Heating Drop in equivalent of BW1606J2F Output Power: 30 kw Anode voltage: 10 kv max Anode dissipation: 15 kw max Frequency up to 30 MHz Manufactured in India, in

More information

CAUTION: To prevent damage to your equipment, thoroughly study all instructions and illustrations before you begin to install the extension.

CAUTION: To prevent damage to your equipment, thoroughly study all instructions and illustrations before you begin to install the extension. I N S T R U C T I O N M A N U A L The Christie Vivid extension is an easy to install option designed to provide quick height adjustment for your installation needs. This extension can be secured to ceilings

More information

Agilent 8703A Lightwave Component Analyzer Technical Specifications

Agilent 8703A Lightwave Component Analyzer Technical Specifications Agilent 8703A Lightwave Component Analyzer Technical Specifications 1300 nm or 1550 nm carrier 130 MHz to 20 GHz modulation bandwidth Single wavelength configuration Introduction 2 A powerful combination

More information

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual TETRIS 1000 High Impedance Active Probe Instruction Manual Copyright 2015 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

Agilent B1500A Semiconductor Device Analyzer

Agilent B1500A Semiconductor Device Analyzer Agilent B1500A Semiconductor Device Analyzer Self-paced Training Manual, 4 Agilent Technologies Notices Agilent Technologies 2005-2008 No part of this manual may be reproduced in any form or by any means

More information

Manual AMERITRON QSK-5PC T/R SWITCH PC BOARD INTRODUCTION

Manual AMERITRON QSK-5PC T/R SWITCH PC BOARD INTRODUCTION Manual Instruction AMERITRON QSK-5PC T/R SWITCH PC BOARD INTRODUCTION The Ameritron QSK-5PC is a PIN diode QSK circuit board designed for use in Ameritron's AL-80A, AL-80B, AL-82, AL-1500 and AL- 1200

More information

MFJ-249B HF/VHF SWR ANALYZER

MFJ-249B HF/VHF SWR ANALYZER TABLE OF CONTENTS MFJ-249B... 2 Introduction... 2 Powering The MFJ-249B... 3 Battery Installation... 3 Alkaline Batteries... 3 NiCd Batteries... 4 Power Saving Mode... 4 Operation Of The MFJ-249B...5 SWR

More information

LM2462 Monolithic Triple 3 ns CRT Driver

LM2462 Monolithic Triple 3 ns CRT Driver LM2462 Monolithic Triple 3 ns CRT Driver General Description The LM2462 is an integrated high voltage CRT driver circuit designed for use in color monitor applications. The IC contains three high input

More information

Keysight Technologies Capacitance Leakage Current Measurement Techniques Using the B2985A/87A

Keysight Technologies Capacitance Leakage Current Measurement Techniques Using the B2985A/87A Keysight Technologies Capacitance Leakage Current Measurement Techniques Using the B2985A/87A B2985A/B2987A Electrometer/High Resistance Meter Technical Overview Introduction Capacitor leakage current

More information

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V B1505A Power Device Analyzer/Curve Tracer Application Note Introduction The input, output and reverse transfer capacitance of

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance 1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

Application Note. Applying DC Bias to Inductors with the 1910 Inductance Analyzer

Application Note. Applying DC Bias to Inductors with the 1910 Inductance Analyzer Applying DC Bias to Inducts with the 1910 Inductance Analyzer The newest instrument in IET Labs. s LCR Product Line is the 1910 Inductance Analyzer. Designed primarily f production testing of inducts,

More information

CSM-S USER S MANUAL TRIGGER DISTRIBUTION MODULE Release April 7, VXI Technology, Inc.

CSM-S USER S MANUAL TRIGGER DISTRIBUTION MODULE Release April 7, VXI Technology, Inc. CSM-S-11056 TRIGGER DISTRIBUTION MODULE USER S MANUAL 82-0051-000 Release April 7, 2003 VXI Technology, Inc. 2031 Main Street Irvine, CA 92614-6509 (949) 955-1894 bus 2 VXI Technology, Inc. www.vxitech.com

More information

Solving Connection Challenges in On-Wafer Power Semiconductor Device Test. Application Note Series. Introduction

Solving Connection Challenges in On-Wafer Power Semiconductor Device Test. Application Note Series. Introduction Number 3276 pplication Note Series Solving Connection Challenges in On-Wafer Power Semiconductor Device Test Introduction Measuring DC and capacitance parameters for high power semiconductor devices requires

More information

MPI TS300-SE 300 mm Manual Probe System with ShielDEnvironment TM For accurate and reliable DC/CV, RF and mmw measurements

MPI TS300-SE 300 mm Manual Probe System with ShielDEnvironment TM For accurate and reliable DC/CV, RF and mmw measurements MPI TS300-SE 300 mm Manual Probe System with ShielDEnvironment TM For accurate and reliable DC/CV, RF and mmw measurements FEATURES / BENEFITS Universal Use Designed for wide variety of applications such

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance 13 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F- Glossary of terms... P.139 Sensor selection guide... P.9~ General precautions... P.1 PHOTO PHOTO

More information

Agilent E1345A 16-Channel Low-Offset Relay Multiplexer. Data Sheet. Description. Configuration. C-size Adapter

Agilent E1345A 16-Channel Low-Offset Relay Multiplexer. Data Sheet. Description. Configuration. C-size Adapter Agilent E1345A 16-Channel Low-Offset Relay Multiplexer Data Sheet 1-Slot, B-size, register based General purpose, low-offset relay multiplexer Low thermal offset reed relays,

More information

LM2412 Monolithic Triple 2.8 ns CRT Driver

LM2412 Monolithic Triple 2.8 ns CRT Driver Monolithic Triple 2.8 ns CRT Driver General Description The is an integrated high voltage CRT driver circuit designed for use in high resolution color monitor applications. The IC contains three high input

More information

2 POLES 5 A LOW PROFILE TYPE

2 POLES 5 A LOW PROFILE TYPE POWER RELAY POLES A LOW PROFILE TYPE FTR-F1 SERIES FEATURES Low profile power relay (height 1. mm) employing unique construction DPST/DPDT A, TV-3 rating available Higher isolation by employing reinforced

More information

Op Amp Booster Designs

Op Amp Booster Designs Op Amp Booster Designs Although modern integrated circuit operational amplifiers ease linear circuit design, IC processing limits amplifier output power. Many applications, however, require substantially

More information

What Is An SMU? SEP 2016

What Is An SMU? SEP 2016 What Is An SMU? SEP 2016 Agenda SMU Introduction Theory of Operation (Constant Current/Voltage Sourcing + Measure) Cabling : Triax vs Coax Advantages in Resistance Applications (vs. DMMs) Advantages in

More information

BIPOLAR ANALOG INTEGRATED CIRCUIT

BIPOLAR ANALOG INTEGRATED CIRCUIT DATA SHEET BIPOLAR ANALOG INTEGRATED CIRCUIT µpc3223tb V, SILICON MMIC MEDIUM OUTPUT POWER AMPLIFIER DESCRIPTION The µpc3223tb is a silicon monolithic IC designed as IF amplifier for DBS tuners. This IC

More information

Agilent U1231A/U1232A/U1233A Handheld Multimeter. Quick Start Guide

Agilent U1231A/U1232A/U1233A Handheld Multimeter. Quick Start Guide Agilent U3A/U3A/U33A Handheld Multimeter Quick Start Guide Verify that you received the following items in the shipment of your multimeter: One pair of red and black test leads Four.5 V AAA alkaline battery

More information

PET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F

PET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F Forced-Air Cooled Triode For Industrial RF Heating Drop in equivalent of BW1610F Output Power: 30 kw Anode voltage: 9 kv max Anode dissipation: 10 kw max Frequency up to 30 MHz Manufactured in India, in

More information

University of Pennsylvania Department of Electrical and Systems Engineering ESE319

University of Pennsylvania Department of Electrical and Systems Engineering ESE319 University of Pennsylvania Department of Electrical and Systems Engineering ESE39 Laboratory Experiment Parasitic Capacitance and Oscilloscope Loading This lab is designed to familiarize you with some

More information

Keysight Technologies Resistance Measurements Using the B2900A Series of SMUs

Keysight Technologies Resistance Measurements Using the B2900A Series of SMUs Keysight Technologies Resistance urements Using the B2900A Series of SMUs Application Note Keysight B2901A Precision SMU, 1ch, 100 fa resolution, 210, 3A DC/10.5 A pulse Keysight B2902A Precision SMU,

More information

CMOS Micro-Power Comparator plus Voltage Follower

CMOS Micro-Power Comparator plus Voltage Follower Freescale Semiconductor Technical Data Rev 2, 05/2005 CMOS Micro-Power Comparator plus Voltage Follower The is an analog building block consisting of a very-high input impedance comparator. The voltage

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Linear Proximity Sensor with High-accuracy Resolution Resolution is 0.05% of the maximum sensing distance. The model with a sensing distance of 1.2 mm ensures a resolution of

More information

Fast IC Power Transistor with Thermal Protection

Fast IC Power Transistor with Thermal Protection Fast IC Power Transistor with Thermal Protection Introduction Overload protection is perhaps most necessary in power circuitry. This is shown by recent trends in power transistor technology. Safe-area,

More information

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0 Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.

More information

Model 7000 Low Noise Differential Preamplifier

Model 7000 Low Noise Differential Preamplifier Model 7000 Low Noise Differential Preamplifier Operating Manual Service and Warranty Krohn-Hite Instruments are designed and manufactured in accordance with sound engineering practices and should give

More information

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight Technologies MEMS On-wafer Evaluation in Mass Production Keysight Technologies MEMS On-wafer Evaluation in Mass Production Testing at the Earliest Stage is the Key to Lowering Costs Application Note Introduction Recently, various devices using MEMS technology

More information

Voltage Sensors URV5-Z

Voltage Sensors URV5-Z Data sheet Version 05.00 Voltage Sensors URV5-Z May 2005 Universal voltage measurements from RF to microwaves The voltage sensors of the URV5-Z series are indispensable tools in RF and microwave laboratories,

More information

LM V Monolithic Triple Channel 15 MHz CRT DTV Driver

LM V Monolithic Triple Channel 15 MHz CRT DTV Driver 220V Monolithic Triple Channel 15 MHz CRT DTV Driver General Description The is a triple channel high voltage CRT driver circuit designed for use in DTV applications. The IC contains three high input impedance,

More information

Keysight 4082A Parametric Test System. Data Sheet

Keysight 4082A Parametric Test System. Data Sheet Keysight 4082A Parametric Test System Data Sheet 02 Keysight 4082A Parametric Test System - Data Sheet General Description Contents General Description... 2 Specification... 4 DC Measurement Subsystem

More information

Aries. CSP center probe socket. prepared by. Gert Hohenwarter. DC Measurement Results

Aries. CSP center probe socket. prepared by. Gert Hohenwarter. DC Measurement Results Aries CSP center probe socket DC Measurement Results prepared by Gert Hohenwarter 8/6/2004 1 Table of Contents TABLE OF CONTENTS... 2 OBJECTIVE... 3 METHODOLOGY... 3 Test procedures... 4 Setup... 4 MEASUREMENTS...

More information

Achieving 3000 V test at the wafer level

Achieving 3000 V test at the wafer level Achieving 3000 V test at the wafer level Bryan Root 1, Alex Pronin 2, Seng Yang 1,Bill Funk 1, K. Armendariz 1 1 Celadon Systems Inc., 2 Keithley September 2016 Outline Introduction Si, SiC and GaN Power

More information

DIGIT & POINTER MULTIMETER

DIGIT & POINTER MULTIMETER CONTENTS DIGIT & POINTER MULTIMETER OPERATOR S MANUAL 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DURING USE 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 3 2. DESCRIPTION 4 2.1 NAMES OF COMPONENTS 4 2.2 FUNCTION

More information

E2V Technologies M5187F X-Band Magnetron

E2V Technologies M5187F X-Band Magnetron E2V Technologies M5187F X-Band Magnetron The data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Fixed frequency pulse magnetron. It is a direct replacement for the M515 but offers

More information

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical DC - 5MHz High Voltage Amplifier WMA-320 www.falco-systems.com USER MANUAL -0V to +0V output DC to 5MHz @ -3dB large signal bandwidth 1300V/µs slew rate typical ±300mA Output current limit Stable with

More information

EMC Accessories Catalog

EMC Accessories Catalog EMC Accessories Catalog A fully equipped electromagnetic compatibility (EMC) laboratory requires a wide variety of instruments, equipment, and accessories to allow measurements to be made accurately and

More information

Accessories Selection Guide For Impedance Measurements. April 2005

Accessories Selection Guide For Impedance Measurements. April 2005 Accessories Selection Guide For Impedance Measurements April 2005 Table of Contents Introduction 1 1. What are Agilent Accessories? 1 2. Types of Accessories 1 3. The Benefits of Agilent Accessories 2

More information

Self-powered Tachometer

Self-powered Tachometer Self-powered Tachometer H7ER Revolutions displayed up to five digits. Dual revolution display accding to encoder resolution used; 1000 s 1 /1000 min 1 1000.0 s 1 /1000.0 min 1 Switchable dual revolution

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

Keysight U1461A Insulation Multimeter/ U1453A Insulation Tester

Keysight U1461A Insulation Multimeter/ U1453A Insulation Tester Keysight U46A Insulation Multimeter/ U453A Insulation Tester Quick Start Guide Standard Accessories Included In Your Purchase Standard Accessories Included In Your Purchase The following accessories are

More information

NCS3 Series Isolated 3W 4:1 Input Single Output DC-DC Converters

NCS3 Series Isolated 3W 4:1 Input Single Output DC-DC Converters FEATURES UL 9 recognised 4:1 Wide range voltage input Operating temperature range - C to 85 C with derating 1.5 kvdc Isolation Hi Pot Test 3.3V, 5V, & 15V outputs No electrolytic capacitors Continuous

More information

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL Model: PR-55 High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL 1 2017 All rights reserved. B&K Precision products are covered by US and foreign patents, issued and pending. Information is this

More information

IC-781: Installing the Inrad Roofing Filter Mod

IC-781: Installing the Inrad Roofing Filter Mod IC-781: Installing the Inrad Roofing Filter Mod The Icom IC-781 roofing filter mod consists of a 6-pole, 4 to 5 khz wide filter followed by a high dynamic range, feedback amplifier. The amplifier provides

More information

E2V Technologies MG5222 X-Band Magnetron

E2V Technologies MG5222 X-Band Magnetron E2V Technologies MG5222 X-Band Magnetron The data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Fixed frequency pulse magnetron. Direct replacement for the M5039, being mechanically

More information

411LA Broadband Power Amplifier

411LA Broadband Power Amplifier 411LA Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with

More information

Model SR554 Transformer Preamplifier

Model SR554 Transformer Preamplifier Model SR554 Transformer Preamplifier Model SR554 Transformer Preamplifier 1290-D Reamwood Avenue Sunnyvale, California 94089 Phone: (408) 744-9040 Fax: (408) 744-9049 email: info@thinksrs.com www.thinksrs.com

More information

TA MHz oscilloscope probe TA MHz oscilloscope probe

TA MHz oscilloscope probe TA MHz oscilloscope probe TA375 100 MHz oscilloscope probe TA386 200 MHz oscilloscope probe User's Guide X1 X10 TA386 X1/X10 Max. 600 Vp Introduction This passive high-impedance oscilloscope probe is suitable for most oscilloscopes

More information

INTERNATIONAL RADIO CORP

INTERNATIONAL RADIO CORP I N R A D INTERNATIONAL RADIO CORP 13620 Tyee Road Umpqua, OR 97486 (541) 459-5623 fax (541) 459 5632 E-mail: inrad@rosenet.net www.qth.com/inrad IC-775 ROOFING FILTER INSTALLATION INSTRUCTIONS The IC-775

More information

5700A/5720A Series II Multi-Function Calibrator

5700A/5720A Series II Multi-Function Calibrator 5700A/5720A Series II Multi-Function Calibrator Operator Guide PN 601648 May 1996 1996 Fluke Corporation, Inc. All rights reserved. Printed in U.S.A. Contents What is in this Guide?... 2 Safety Summary...

More information

TK 100 Probe Calibrator. Instruction Manual

TK 100 Probe Calibrator. Instruction Manual TK 100 Probe Calibrator Instruction Manual Copyright 2013 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications are subject

More information

Assembly Instructions for the 1.5 Watt Amplifier Kit

Assembly Instructions for the 1.5 Watt Amplifier Kit Assembly Instructions for the 1.5 Watt Amplifier Kit 1.) All of the small parts are attached to a sheet of paper indicating both their value and id. 2.) Leave the parts affixed to the paper until you are

More information

User s Manual Current Probe. IM E 2nd Edition IM E

User s Manual Current Probe. IM E 2nd Edition IM E User s Manual 700937 Current Probe 2nd Edition Introduction Thank you for purchasing the 700937 Current Probe. This Instruction Manual contains useful information about the instrument s functions and operating

More information

R-X SERIES. Decade Resistor

R-X SERIES. Decade Resistor PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT R-X SERIES Decade Resistor User and Service Manual Effectivity: Serial Numbers beginning with P2 RX im/august, 2002 Copyright 2002 IET Labs, Inc. IET LABS,

More information

5700A/5720A. Operator Guide. Series II Multi-Function Calibrator

5700A/5720A. Operator Guide. Series II Multi-Function Calibrator 5700A/5720A Series II Multi-Function Calibrator Operator Guide PN 3474006 May 1996, Rev. 1, 5/09 2009 Fluke Corporation. All rights reserved. Printed in USA. All product names are trademarks of their respective

More information

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2. TA046 800 MHz ±30 V Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2-031 CAT I, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING Warning

More information