BLACKBODY RADIATION PHYSICS 359E
|
|
- Edgar Little
- 6 years ago
- Views:
Transcription
1 BLACKBODY RADIATION PHYSICS 359E INTRODUCTION In this laboratory, you will make measurements intended to illustrate the Stefan-Boltzmann Law for the total radiated power per unit area I tot (in W m 2 ) emitted by a blackbody at temperature T to its surroundings I tot = σ SB T 4, (1) where σ SB is the Stefan-Boltzmann constant. The Planck blackbody radiation Law for the dependence of monochromatic emission I(λ) on wavelength and temperature (energy radiated per second per unit area per unit wavelength interval, radiated into one steradian of solid angle; W m 2 m 1 ster 1 )is 2c 2 h I(λ) = λ 5 [exp(hc/kt λ) 1]. (2) From the data you will obtain during this experiment, you should be able to estimate both the Stefan-Boltzmann constant σ SB, and the constant hc/k. You will also learn something about the detection of infrared radiation and the use of lock-in amplifiers. PRE-LABORATORY PREPARATION 1. Familiarize yourself with the Stefan-Boltzmann Law, the Wien Displacement Law, and the Blackbody Radiation Law (see Refs. 1 through 4; be sure to read at least one of these before class). 2. Look up the variation of the resistivity and emissivity of tungsten with temperature (see Ref. 5; the resistivity data are also available as a table and a graph from the course Web page). 3. Look over the manual for the lock-in amplifier to become familiar with the theory of its operation and how to use it. APPARATUS To carry out this experiment you will need a blackbody, a detection system, and some device to place between source and detector for wavelength selection. Blackbody Our approximation to a blackbody is a tungsten filament lamp powered by a stable current source. Temperatures as high as 2500 K can be readily reached with such a lamp. (In what sense does such a lamp differ from a true blackbody?). To obtain the temperature of the lamp, we measure both the current I l flowing through it and the voltage V l appearing across it. The resistance which can be calculated from these values can be used to obtain the filament temperature, provided that the resistivity of tungsten as a function of temperature is known, and provided that the value of 1
2 the resistance of the lamp at some independently known temperature (usually room temperature) is known. Measurement of V l and I l also allow one to calculate the electrical power being supplied to the filament. Since the electrical input power will be equal to the net power radiated per second from the filament (why?), we can use V l and I l to determine the radiated power I tot emitted by the lamp. Detection system If we make measurements in the spectral region from 500 nm to 2500 nm as the temperature of the lamp is increased to 2500 K, we will explore much of the blackbody curve. (You should verify this statement using Wien s displacement law). To do this may require two detectors: a silicon photodiode which is sensitive in the visible and the near infrared (to about 1060 nm) spectral regions, and a lead sulphide photoconductor which is sensitive to about 3000 nm. Use of the silicon photodiode is straightforward: we let the light fall on it and measure the current that flows through the diode. The lead sulphide detector is a bit more complicated. The conductivity γ of the detector varies with the amount of radiation I falling on it as γ = γ 1 + γ 2 I. (3) For low light intensity, the second term in this equation is small compared to the first, and the resistance of the lead sulphide detector will decrease linearly with I (convince yourself of this). Consequently, the simplest way to use the lead sulphide detector is shown below, where the load resistor R is chosen to be about equal to the dark resistance of the detector. The change in the voltage V measured across the load, relative to the value for I = 0, is directly proportional to the radiation intensity I (again, convince yourself). However, if one measures the noise (i.e. fluctuations in the measured voltage V ) from such a system as a function of frequency f, one finds that the noise grows dramatically towards low frequencies (as 1/f) as shown in the log log plot below: The presence of this characteristic 1/f noise at low frequency means that we could measure smaller changes in V if the signal were modulated at a frequency high enough to avoid the noise. We achieve this by putting a chopper in the beam to interrupt the light at a suitable frequency f. (The best place to put the chopper is as close to the lamp as possible. Why?) The voltage V across the load resistor will now be a tiny square wave at frequency f (superimposed on a DC offset). We want to measure the amplitude of this small square wave. For this we use a lock-in amplifier. This is a very useful instrument whose main purpose is to measure the amplitude of the fundamental component of a signal at frequency f within a bandwidth 2
3 df while rejecting any input (i.e. noise) outside this bandwidth. To do this it needs a reference signal at the required frequency, and the chopper just happens to provide such a signal. A valuable characteristic of the lock-in is that it will remain locked on to the reference frequency even if it drifts (slowly enough!) and will still measure the required amplitude. (See the manual for the lock-in for a more detailed description of how it works. It can also be used for phase measurements.) A noise source is provided to allow you to observe how the lock-in amplifier can significantly improve the signal-to-noise ratio (S/N) in the measurement of the amplitude of a periodic signal. You can choose between white noise, line frequency noise (predominantly 60 Hz), and noise generated by light sources in the lab such as fluorescent lights. PROCEDURE 1. You will start by learning about the lock-in amplifier using artificially generated signals. Signals are generated by a Wavetek function generator, which can make a wide range of calibrated waveforms for you at frequencies between mhz and MHz and with amplitudes down to mv. This signal source is supplemented by a noise source: as the signal from the Wavetek is passed through the noise source, noise is added to the signal. Use the oscilloscope to familiarize yourself with the outputs obtainable from these two devices. Now to explore the ability of the lock-in amplifier to detect weak signals buried in noise, we must provide the lock-in with a reference frequency. The reference input of the lock-in requires a periodic signal of amplitude between 0.2 and 5 V. The SYNC output on the back of the Wavetek function generator is suitable (check this on the oscilloscope!). A light on the front panel of the lock-in will go off, indicating that it has accepted the reference. Connect a sine wave output from the Wavetek at the same frequency as the reference to the noise source and observe the SUM output directly on the oscilloscope. Choose amplitudes such that the sum output will not exceed the maximum signal input for the lock-in. Connect the sum output to the signal input of the lock-in. Adjust the gain and phase as necessary and record the S/N of the output for various time constant settings. Repeat this exercise for different input S/N values. You can also experiment with different noise sources, such as the fluorescent lights, using the photodetector in the noise box. If you do this, try tuning the frequency generated by the Wavetek slowly around a noise frequency and its harmonics present in the source (e.g. 60Hz, 120 Hz,..) and observe the lock-in output. Tabulate the results of your experiments and explain them. 2. Measure the room temperature resistance of the filament of the tungsten lamp. This is an important measurement since any error will lead to a systematic error in the inferred lamp temperature. Since a digital multimeter puts very little current through the resistance, and thus heats it very 3
4 little above room temperature, it is safe to use one to measure the room temperature resistance. 3. Measure the intensity of the lamp for at least 3 4 different wavelengths, using the filters provided, at 8 or more different temperatures obtained by increasing the voltage and current to the lamp. Record your measurements of both V and I (why?). Do a series of temperatures with a single filter, then move on to the next filter. Be very careful not to move anything (the lamp, any lenses, the filter, the detector) in the optical path while you are doing one temperature series (why?). In setting up the apparatus you will have to decide how far to put the detectors from the lamp and whether to use a lens to image the lamp onto the detector. The basis for your decision should be whether you have enough signal at the lowest temperature without saturating the detector at the highest temperature. Do not exceed a voltage of 125 V on the bulb! 4. Estimate the area of the filament. You need this to get σ SB. Note that the filament is not a straight wire, but a tiny, tightly wound spiral coil. ANALYSIS 1. Find a value for hc/k from your data. (With care, your value could be within 5% of the accepted value aim for this.) Try plotting ln[λ 5 I(λ)] vs. 1/λT. (Should you use a series of data at one value of λ, oratonevalueoft? Why?) There should be a straight line whose slope will give you hc/k. Why is there a straight line region? Will the data for all filters lie on the same line? 2. Verify the Stefan-Boltzmann Law by plotting I tot vs T 4 and obtain an approximate value for σ SB. Note that since the tungsten filament is not a perfect blackbody, the Stefan-Boltzmann Law should be used in the modified form I tot = eσ SB (T 4 T 4 0 ) (4) where e is the emissivity (e depends on temperature; its variation can be found in Ref. 5) and T 0 is the room temperature (the T 0 term includes in the net power radiated [I tot ] the power absorbed by the lamp from the room). REPORT Include in your report: a summary of your experiments using the lock-in to detect weak periodic signals in the presence of noise. an example of one of your data sets of I(λ) vst, displayed graphically with suitable scales. your analysis leading to a value of hc/k (including a relevant graph as an example), with an estimate of uncertainty; include an explanation of why the graph you use enables you to determine hc/k. your analysis confirming the Stefan-Boltzmann Law (include a graph of I tot vs T 4 ), and a discussion of your value for σ SB, again with an error analysis. 4
5 REFERENCES 1. D. Halliday, R. Resnick and K. S. Krane, Physics, extended version (John Wiley & Sons, New York, 1992), Secs 49-1 and R. Eisberg and R. Resnick, Quantum Physics of Atoms, Molecules, Solids, Nuclei and Particles (John Wiley & Sons, New York, 1985), Ch P.A. Tipler, Modern Physics, (Worth, New York, 1978), S F.K. Richtmyer, E.H. Kennard, and J.N. Cooper, Introduction to Modern Physics, 6 ed. (McGraw-Hill, 1969), Ch Handbook of Chemistry and Physics (CRC Press). 5
Black Body Radiation. References: P.A. Tipler, Modern Physics, pp (Worth Publishers, Inc., NY, 1978).
Black Body Radiation References: P.A. Tipler, Modern Physics, pp. 102-107 (Worth Publishers, Inc., NY, 1978). Read carefully the material in this reference or any other Modern Physics text. The goal of
More informationPhysics 262. Lab #1: Lock-In Amplifier. John Yamrick
Physics 262 Lab #1: Lock-In Amplifier John Yamrick Abstract This lab studied the workings of a photodiode and lock-in amplifier. The linearity and frequency response of the photodiode were examined. Introduction
More informationUV-VIS-IR Spectral Responsivity Measurement System for Solar Cells
November 1998 NREL/CP-52-25654 UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells H. Field Presented at the National Center for Photovoltaics Program Review Meeting, September 8 11, 1998,
More informationECEN 4606, UNDERGRADUATE OPTICS LAB
ECEN 4606, UNDERGRADUATE OPTICS LAB Lab 10: Photodetectors Original: Professor McLeod SUMMARY: In this lab, you will characterize the fundamental low-frequency characteristics of photodiodes and the circuits
More informationThe 34th International Physics Olympiad
The 34th International Physics Olympiad Taipei, Taiwan Experimental Competition Wednesday, August 6, 2003 Time Available : 5 hours Please Read This First: 1. Use only the pen provided. 2. Use only the
More informationI = I 0 cos 2 θ (1.1)
Chapter 1 Faraday Rotation Experiment objectives: Observe the Faraday Effect, the rotation of a light wave s polarization vector in a material with a magnetic field directed along the wave s direction.
More informationBME 3512 Bioelectronics Laboratory Five - Operational Amplifiers
BME 351 Bioelectronics Laboratory Five - Operational Amplifiers Learning Objectives: Be familiar with the operation of a basic op-amp circuit. Be familiar with the characteristics of both ideal and real
More informationPhotoelectric effect
Photoelectric effect Objective Study photoelectric effect. Measuring and Calculating Planck s constant, h. Measuring Current-Voltage Characteristics of photoelectric Spectral Lines. Theory Experiments
More informationBME/ISE 3512 Bioelectronics. Laboratory Five - Operational Amplifiers
BME/ISE 3512 Bioelectronics Laboratory Five - Operational Amplifiers Learning Objectives: Be familiar with the operation of a basic op-amp circuit. Be familiar with the characteristics of both ideal and
More informationClass #9: Experiment Diodes Part II: LEDs
Class #9: Experiment Diodes Part II: LEDs Purpose: The objective of this experiment is to become familiar with the properties and uses of LEDs, particularly as a communication device. This is a continuation
More information1 Lock-in Amplifier Introduction
1 Lock-in Amplifier Introduction The purpose of this laboratory is to introduce the student to the lock-in amplifier. A lock-in amplifier is a nearly ubiquitous piece of laboratory equipment, and can serve
More informationCalibration of a High Dynamic Range, Low Light Level Visible Source
Calibration of a High Dynamic Range, Low Light Level Visible Source Joe LaVeigne a, Todd Szarlan a, Nate Radtke a a Santa Barbara Infrared, Inc., 30 S. Calle Cesar Chavez, #D, Santa Barbara, CA 93103 ABSTRACT
More informationJohnson Noise and the Boltzmann Constant
Johnson Noise and the Boltzmann Constant 1 Introduction The purpose of this laboratory is to study Johnson Noise and to measure the Boltzmann constant k. You will also get use a low-noise pre-amplifier,
More informationPh 3455 The Photoelectric Effect
Ph 3455 The Photoelectric Effect Required background reading Tipler, Llewellyn, section 3-3 Prelab Questions 1. In this experiment you will be using a mercury lamp as the source of photons. At the yellow
More informationMEASURING HUM MODULATION USING MATRIX MODEL HD-500 HUM DEMODULATOR
MEASURING HUM MODULATION USING MATRIX MODEL HD-500 HUM DEMODULATOR The SCTE defines hum modulation as, The amplitude distortion of a signal caused by the modulation of the signal by components of the power
More informationSECOND HARMONIC GENERATION AND Q-SWITCHING
SECOND HARMONIC GENERATION AND Q-SWITCHING INTRODUCTION In this experiment, the following learning subjects will be worked out: 1) Characteristics of a semiconductor diode laser. 2) Optical pumping on
More informationSpectrometer using a tunable diode laser
Spectrometer using a tunable diode laser Ricardo Vasquez Department of Physics, Purdue University, West Lafayette, IN April, 2000 In the following paper the construction of a simple spectrometer using
More informationModern Physics Laboratory MP4 Photoelectric Effect
Purpose MP4 Photoelectric Effect In this experiment, you will investigate the photoelectric effect and determine Planck s constant and the work function. Equipment and components Photoelectric Effect Apparatus
More informationSpring 2004 M2.1. Lab M2. Ultrasound: Interference, Wavelength, and Velocity
Spring 2004 M2.1 Lab M2. Ultrasound: Interference, Wavelength, and Velocity The purpose in this lab exercise is to become familiar with the properties of waves: frequency, wavelength, phase and velocity.
More informationEnergy in Photons. Light, Energy, and Electron Structure
elearning 2009 Introduction Energy in Photons Light, Energy, and Electron Structure Publication No. 95007 Students often confuse the concepts of intensity of light and energy of light. This demonstration
More informationOptical Modulation and Frequency of Operation
Optical Modulation and Frequency of Operation Developers AB Overby Objectives Preparation Background The objectives of this experiment are to describe and illustrate the differences between frequency of
More informationExperiment 1: Fraunhofer Diffraction of Light by a Single Slit
Experiment 1: Fraunhofer Diffraction of Light by a Single Slit Purpose 1. To understand the theory of Fraunhofer diffraction of light at a single slit and at a circular aperture; 2. To learn how to measure
More informationTSL267 HIGH-SENSITIVITY IR LIGHT-TO-VOLTAGE CONVERTER TAOS033E SEPTEMBER 2007
TSL267 Integral Visible Light Cutoff Filter Converts IR Light Intensity to Output Voltage Monolithic Silicon IC Containing Photodiode, Operational Amplifier, and Feedback Components High Sensitivity Single
More informationDESIGN OF AN ANALOG FIBER OPTIC TRANSMISSION SYSTEM
DESIGN OF AN ANALOG FIBER OPTIC TRANSMISSION SYSTEM OBJECTIVE To design and build a complete analog fiber optic transmission system, using light emitting diodes and photodiodes. INTRODUCTION A fiber optic
More informationPhysics Laboratory Scattering of Photons from Electrons: Compton Scattering
RR Oct 2001 SS Dec 2001 MJ Oct 2009 Physics 34000 Laboratory Scattering of Photons from Electrons: Compton Scattering Objective: To measure the energy of high energy photons scattered from electrons in
More informationWavelength Control and Locking with Sub-MHz Precision
Wavelength Control and Locking with Sub-MHz Precision A PZT actuator on one of the resonator mirrors enables the Verdi output wavelength to be rapidly tuned over a range of several GHz or tightly locked
More informationPHYSICS 330 LAB Operational Amplifier Frequency Response
PHYSICS 330 LAB Operational Amplifier Frequency Response Objectives: To measure and plot the frequency response of an operational amplifier circuit. History: Operational amplifiers are among the most widely
More informationPh 3455 The Franck-Hertz Experiment
Ph 3455 The Franck-Hertz Experiment Required background reading Tipler, Llewellyn, section 4-5 Prelab Questions 1. In this experiment, we will be using neon rather than mercury as described in the textbook.
More informationUltraviolet Visible Infrared Instrumentation
Ultraviolet Visible Infrared Instrumentation Focus our attention on measurements in the UV-vis region of the EM spectrum Good instrumentation available Very widely used techniques Longstanding and proven
More informationPCS-150 / PCI-200 High Speed Boxcar Modules
Becker & Hickl GmbH Kolonnenstr. 29 10829 Berlin Tel. 030 / 787 56 32 Fax. 030 / 787 57 34 email: info@becker-hickl.de http://www.becker-hickl.de PCSAPP.DOC PCS-150 / PCI-200 High Speed Boxcar Modules
More informationLab VIII Photodetectors ECE 476
Lab VIII Photodetectors ECE 476 I. Purpose The electrical and optical properties of various photodetectors will be investigated. II. Background Photodiode A photodiode is a standard diode packaged so that
More informationPHY 123/253 Shot Noise
PHY 123/253 Shot Noise HISTORY Complete Pre- Lab before starting this experiment In 1918, experimental physicist Walter Scottky working in the research lab at Siemens was investigating the origins of noise
More informationFirst and second order systems. Part 1: First order systems: RC low pass filter and Thermopile. Goals: Department of Physics
slide 1 Part 1: First order systems: RC low pass filter and Thermopile Goals: Understand the behavior and how to characterize first order measurement systems Learn how to operate: function generator, oscilloscope,
More informationOscilloscope Measurements
PC1143 Physics III Oscilloscope Measurements 1 Purpose Investigate the fundamental principles and practical operation of the oscilloscope using signals from a signal generator. Measure sine and other waveform
More informationPHY385H1F Introductory Optics Term Test 2 November 6, 2012 Duration: 50 minutes. NAME: Student Number:.
PHY385H1F Introductory Optics Term Test 2 November 6, 2012 Duration: 50 minutes NAME: Student Number:. Aids allowed: A pocket calculator with no communication ability. One 8.5x11 aid sheet, written on
More informationams AG TAOS Inc. is now The technical content of this TAOS datasheet is still valid. Contact information:
TAOS Inc. is now The technical content of this TAOS datasheet is still valid. Contact information: Headquarters: Tobelbaderstrasse 3 84 Unterpremstaetten, Austria Tel: +43 () 336 5 e-mail: ams_sales@ams.com
More informationOHM S LAW. Ohm s Law The relationship between potential difference (V) across a resistor of resistance (R) and the current (I) passing through it is
OHM S LAW Objectives: a. To find the unknown resistance of an ohmic resistor b. To investigate the series and parallel combination of resistors c. To investigate the non-ohmic resistors Apparatus Required:
More informationThe preferred Exercise is shown in Exercises 5B or 5C.
ECE 231 Laboratory Exercise 5A The preferred Exercise is shown in Exercises 5B or 5C. Laboratory Group (Names) OBJECTIVES Validate the Schottky diode equation. Calculate the dc and dynamic (ac) resistance
More informationThe Photoelectric Effect
The Photoelectric Effect 1 The Photoelectric Effect Overview: The photoelectric effect is the light-induced emission of electrons from an object, in this case from a metal electrode inside a vacuum tube.
More information... frequency, f speed, v......
PhysicsAndMathsTutor.com 1 1. Define the terms wavelength, frequency and speed used to describe a progressive wave. wavelength, λ... frequency, f... speed, v... Hence derive the wave equation v = fλ which
More informationLINEARPYROMETER LP4. Technical Documentation KE November TN
1 LINEARPYROMETER LP4 Technical Documentation KE 256-6.2007 November 2010 5-TN-1622-100 2 1. General Description With the Linearpyrometer Type LP4 a measuring instrument has been made available for pyrometric
More informationPHY203: General Physics III Lab page 1 of 5 PCC-Cascade. Lab: AC Circuits
PHY203: General Physics III Lab page 1 of 5 Lab: AC Circuits OBJECTIVES: EQUIPMENT: Universal Breadboard (Archer 276-169) 2 Simpson Digital Multimeters (464) Function Generator (Global Specialties 2001)*
More informationIntegrators, differentiators, and simple filters
BEE 233 Laboratory-4 Integrators, differentiators, and simple filters 1. Objectives Analyze and measure characteristics of circuits built with opamps. Design and test circuits with opamps. Plot gain vs.
More informationThermal Johnson Noise Generated by a Resistor
Thermal Johnson Noise Generated by a Resistor Complete Pre- Lab before starting this experiment HISTORY In 196, experimental physicist John Johnson working in the physics division at Bell Labs was researching
More informationME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION
Objectives: ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION The primary goal of this laboratory is to study the operation and limitations of several commonly used pieces of instrumentation:
More information8.5 Modulation of Signals
8.5 Modulation of Signals basic idea and goals measuring atomic absorption without modulation measuring atomic absorption with modulation the tuned amplifier, diode rectifier and low pass the lock-in amplifier
More informationLLS - Introduction to Equipment
Published on Advanced Lab (http://experimentationlab.berkeley.edu) Home > LLS - Introduction to Equipment LLS - Introduction to Equipment All pages in this lab 1. Low Light Signal Measurements [1] 2. Introduction
More informationWhen you have completed this exercise, you will be able to relate the gain and bandwidth of an op amp
Op Amp Fundamentals When you have completed this exercise, you will be able to relate the gain and bandwidth of an op amp In general, the parameters are interactive. However, in this unit, circuit input
More information225 Lock-in Amplifier
225 Lock-in Amplifier 225.02 Bentham Instruments Ltd 1 2 Bentham Instruments Ltd 225.02 1. WHAT IS A LOCK-IN? There are a number of ways of visualising the operation and significance of a lock-in amplifier.
More informationHomework Set 3.5 Sensitive optoelectronic detectors: seeing single photons
Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons Due by 12:00 noon (in class) on Tuesday, Nov. 7, 2006. This is another hybrid lab/homework; please see Section 3.4 for what you
More informationUniversity of Wisconsin Chemistry 524 Spectroscopic Components *
University of Wisconsin Chemistry 524 Spectroscopic Components * In journal articles, presentations, and textbooks, chemical instruments are often represented as block diagrams. These block diagrams highlight
More informationSolar Cell Parameters and Equivalent Circuit
9 Solar Cell Parameters and Equivalent Circuit 9.1 External solar cell parameters The main parameters that are used to characterise the performance of solar cells are the peak power P max, the short-circuit
More informationMulti-photon Absorption in Optical Pumping of Rubidium
Multi-photon Absorption in Optical Pumping of Rubidium Xinyi Xu (ID PIN:A51481739) Department of Physics and Astronomy Michigan State University Abstract: In optical pumping of rubidium, a new kind of
More informationCoherent Receivers Principles Downconversion
Coherent Receivers Principles Downconversion Heterodyne receivers mix signals of different frequency; if two such signals are added together, they beat against each other. The resulting signal contains
More informationDIODE LASER SPECTROSCOPY (160309)
DIODE LASER SPECTROSCOPY (160309) Introduction The purpose of this laboratory exercise is to illustrate how we may investigate tiny energy splittings in an atomic system using laser spectroscopy. As an
More informationTechnical Explanation for Displacement Sensors and Measurement Sensors
Technical Explanation for Sensors and Measurement Sensors CSM_e_LineWidth_TG_E_2_1 Introduction What Is a Sensor? A Sensor is a device that measures the distance between the sensor and an object by detecting
More informationPart 2: Second order systems: cantilever response
- cantilever response slide 1 Part 2: Second order systems: cantilever response Goals: Understand the behavior and how to characterize second order measurement systems Learn how to operate: function generator,
More informationMaltase cross tube. D. Senthilkumar P a g e 1
Thermionic Emission Maltase cross tube Definition: The emission of electrons when a metal is heated to a high temperature Explanation: In metals, there exist free electrons which are able to move around
More informationIt s Our Business to be EXACT
671 LASER WAVELENGTH METER It s Our Business to be EXACT For laser applications such as high-resolution laser spectroscopy, photo-chemistry, cooling/trapping, and optical remote sensing, wavelength information
More informationTSL253R LIGHT-TO-VOLTAGE OPTICAL SENSOR
Monolithic Silicon IC Containing Photodiode, Operational Amplifier, and Feedback Components Converts Light Intensity to a Voltage High Irradiance Responsivity, Typically 37 mv/(w/cm 2 ) at p = 635 nm ()
More informationDoppler-Free Spetroscopy of Rubidium
Doppler-Free Spetroscopy of Rubidium Pranjal Vachaspati, Sabrina Pasterski MIT Department of Physics (Dated: April 17, 2013) We present a technique for spectroscopy of rubidium that eliminates doppler
More informationReceiver Design for Passive Millimeter Wave (PMMW) Imaging
Introduction Receiver Design for Passive Millimeter Wave (PMMW) Imaging Millimeter Wave Systems, LLC Passive Millimeter Wave (PMMW) sensors are used for remote sensing and security applications. They rely
More informationLab M6: The Doppler Effect
M6.1 Lab M6: The Doppler Effect Introduction The purpose in this lab is to teach the basic properties of waves (amplitude, frequency, wavelength, and speed) using the Doppler effect. This effect causes
More informationExperiment 2: Transients and Oscillations in RLC Circuits
Experiment 2: Transients and Oscillations in RLC Circuits Will Chemelewski Partner: Brian Enders TA: Nielsen See laboratory book #1 pages 5-7, data taken September 1, 2009 September 7, 2009 Abstract Transient
More informationFriday 18 January 2013 Morning
Friday 18 January 2013 Morning AS GCE PHYSICS A G482/01 Electrons, Waves and Photons *G411580113* Candidates answer on the Question Paper. OCR supplied materials: Data, Formulae and Relationships Booklet
More informationApplication Notes Photoconductive Cells
APPLICATION NOTE #1 Light - Some Physical Basics Light is produced by the release of energy from the atoms of a material when they are excited by heat, chemical reaction or other means. Light travels through
More information2 AC and RMS. To pass this lab you must solve tasks 1-2. Tasks 3 and 4 are included in the grading of the course.
2 AC and RMS Purpose of the lab: to familiarize yourself with the oscilloscope to familiarize yourself with AC voltages and different waveforms to study RMS and average values In this lab, you have the
More informationInvestigate the characteristics of PIN Photodiodes and understand the usage of the Lightwave Analyzer component.
PIN Photodiode 1 OBJECTIVE Investigate the characteristics of PIN Photodiodes and understand the usage of the Lightwave Analyzer component. 2 PRE-LAB In a similar way photons can be generated in a semiconductor,
More informationExperiment 1: Instrument Familiarization (8/28/06)
Electrical Measurement Issues Experiment 1: Instrument Familiarization (8/28/06) Electrical measurements are only as meaningful as the quality of the measurement techniques and the instrumentation applied
More informationTechnical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration
Technical Notes Integrating Sphere Measurement Part II: Calibration This Technical Note is Part II in a three part series examining the proper maintenance and use of integrating sphere light measurement
More informationA Measurement of the Photon Detection Efficiency of Silicon Photomultipliers
A Measurement of the Photon Detection Efficiency of Silicon Photomultipliers A. N. Otte a,, J. Hose a,r.mirzoyan a, A. Romaszkiewicz a, M. Teshima a, A. Thea a,b a Max Planck Institute for Physics, Föhringer
More informationElectron Spin Resonance v2.0
Electron Spin Resonance v2.0 Background. This experiment measures the dimensionless g-factor (g s ) of an unpaired electron using the technique of Electron Spin Resonance, also known as Electron Paramagnetic
More informationUNIVERSITY OF NORTH CAROLINA AT CHARLOTTE Department of Electrical and Computer Engineering
UNIVERSITY OF NORTH CAROLINA AT CHARLOTTE Department of Electrical and Computer Engineering EXPERIMENT 5 GAIN-BANDWIDTH PRODUCT AND SLEW RATE OBJECTIVES In this experiment the student will explore two
More informationNAME SECTION PERFORMANCE TASK # 3. Part I. Qualitative Relationships
NAME SECTION PARTNERS DATE PERFORMANCE TASK # 3 You must work in teams of three or four (ask instructor) and will turn in ONE report. Answer all questions. Write in complete sentences. You must hand this
More informationLAB V. LIGHT EMITTING DIODES
LAB V. LIGHT EMITTING DIODES 1. OBJECTIVE In this lab you are to measure I-V characteristics of Infrared (IR), Red and Blue light emitting diodes (LEDs). The emission intensity as a function of the diode
More informationTSLB257, TSLG257, TSLR257 HIGH-SENSITIVITY COLOR LIGHT-TO-VOLTAGE CONVERTERS TAOS027C JUNE 2006
Converts Light Intensity to Output Voltage Integral Color Filter in Blue, Green, or Red Monolithic Silicon IC Containing Photodiode, Operational Amplifier, and Feedback Components High Sensitivity Single
More informationQuantum Efficiency Measurement System with Internal Quantum Efficiency Upgrade
Quantum Efficiency Measurement System with Internal Quantum Efficiency Upgrade QE / IPCE SYSTEM Upgraded with Advanced Features Includes IV Testing, Spectral Response, Quantum Efficiency System/ IPCE System
More informationPh 77 ADVANCED PHYSICS LABORATORY ATOMIC AND OPTICAL PHYSICS
Ph 77 ADVANCED PHYSICS LABORATORY ATOMIC AND OPTICAL PHYSICS Diode Laser Characteristics I. BACKGROUND Beginning in the mid 1960 s, before the development of semiconductor diode lasers, physicists mostly
More informationTO INVESTIGATE THE VARIATION OF CURRENT (I) WITH P.D. (V) FOR (a) A METALLIC CONDUCTOR
FOR (a) A METALLIC CONDUCTOR Low voltage power supply, rheostat, voltmeter, ammeter, length of nichrome wire. 6 A - Nichrome wire 1. Set up the circuit as shown and set the voltage supply at 6 d.c. 2.
More informationams AG TAOS Inc. is now The technical content of this TAOS datasheet is still valid. Contact information:
TAOS Inc. is now The technical content of this TAOS datasheet is still valid. Contact information: Headquarters: Tobelbaderstrasse 3 84 Unterpremstaetten, Austria Tel: +43 () 336 5 e-mail: ams_sales@ams.com
More informationLaboratory #2 Guide: Measuring the Lamp/Monochromator Output Spectrum
September 3, 2014 Laboratory #2 Guide: Measuring the Lamp/Monochromator Output Spectrum Introduction In the last lab we did a simple exercise to introduce students to the major components in our optical
More informationImproved Radiometry for LED Arrays
RadTech Europe 2017 Prague, Czech Republic Oct. 18, 2017 Improved Radiometry for LED Arrays Dr. Robin E. Wright 3M Corporate Research Process Laboratory, retired 3M 2017 All Rights Reserved. 1 Personal
More informationSDP Low Light Rejection Phototransistor
FEATURES Side-looking plastic package Low light level immunity 50 (nominal) acceptance angle Mechanically and spectrally matched to SEP8506 and SEP8706 infrared emitting diodes INFRA-21.TIF DESCRIPTION
More information[4] (b) Fig. 6.1 shows a loudspeaker fixed near the end of a tube of length 0.6 m. tube m 0.4 m 0.6 m. Fig. 6.
1 (a) Describe, in terms of vibrations, the difference between a longitudinal and a transverse wave. Give one example of each wave.................... [4] (b) Fig. 6.1 shows a loudspeaker fixed near the
More informationNON-AMPLIFIED PHOTODETECTOR USER S GUIDE
NON-AMPLIFIED PHOTODETECTOR USER S GUIDE Thank you for purchasing your Non-amplified Photodetector. This user s guide will help answer any questions you may have regarding the safe use and optimal operation
More informationUndulator K-Parameter Measurements at LCLS
Undulator K-Parameter Measurements at LCLS J. Welch, A. Brachmann, F-J. Decker, Y. Ding, P. Emma, A. Fisher, J. Frisch, Z. Huang, R. Iverson, H. Loos, H-D. Nuhn, P. Stefan, D. Ratner, J. Turner, J. Wu,
More informationBrown University Department of Physics. Physics 6 Spring 2006 A SIMPLE FLUXGATE MAGNETOMETER
Brown University Department of Physics Physics 6 Spring 2006 1 Introduction A SIMPLE FLUXGATE MAGNETOMETER A simple fluxgate magnetometer can be constructed out available equipment in the lab. It can easily
More informationEffect of frequency modulation amplitude on Iodine stabilized He-Ne Laser, at λ 633nm
Egypt. J. Sol., Vol. (26), No. (1), (2003) 103 Effect of frequency modulation amplitude on Iodine stabilized He-Ne Laser, at λ 633nm M. Amer and F. Abdel Aziz National institute for standards, Giza, Egypt.
More informationLEP Optical pumping
Related topics Spontaeous emission, induced emission, mean lifetime of a metastable state, relaxation, inversion, diode laser. Principle and task The visible light of a semiconductor diode laser is used
More informationEXP 9 ESR (Electron Spin Resonance)
EXP 9 ESR (Electron Spin Resonance) Introduction ESR in Theory The basic setup for electron spin resonance is shown in Fig 1. A test sample is placed in a uniform magnetic field. The sample is also wrapped
More informationTest No. 2. Advanced Scope Measurements. History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 2
University of Applied Sciences Hamburg Group No : DEPARTMENT OF INFORMATION ENGINEERING Laboratory for Instrumentation and Measurement L1: in charge of the report Test No. 2 Date: Assistant A2: Professor:
More informationLab 2: Linear and Nonlinear Circuit Elements and Networks
OPTI 380B Intermediate Optics Laboratory Lab 2: Linear and Nonlinear Circuit Elements and Networks Objectives: Lean how to use: Function of an oscilloscope probe. Characterization of capacitors and inductors
More informationR. J. Jones Optical Sciences OPTI 511L Fall 2017
R. J. Jones Optical Sciences OPTI 511L Fall 2017 Semiconductor Lasers (2 weeks) Semiconductor (diode) lasers are by far the most widely used lasers today. Their small size and properties of the light output
More informationSpectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018
1 Spectroscopy of Ruby Fluorescence Physics 3600 - Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018 I. INTRODUCTION The laser was invented in May 1960 by Theodor Maiman.
More informationEE 368 Electronics Lab. Experiment 10 Operational Amplifier Applications (2)
EE 368 Electronics Lab Experiment 10 Operational Amplifier Applications (2) 1 Experiment 10 Operational Amplifier Applications (2) Objectives To gain experience with Operational Amplifier (Op-Amp). To
More informationThe equipment used share any common features regardless of the! being measured. Electronic detection was not always available.
The equipment used share any common features regardless of the! being measured. Each will have a light source sample cell! selector We ll now look at various equipment types. Electronic detection was not
More informationTHE BENEFITS OF DSP LOCK-IN AMPLIFIERS
THE BENEFITS OF DSP LOCK-IN AMPLIFIERS If you never heard of or don t understand the term lock-in amplifier, you re in good company. With the exception of the optics industry where virtually every major
More informationThe FTNIR Myths... Misinformation or Truth
The FTNIR Myths... Misinformation or Truth Recently we have heard from potential customers that they have been told that FTNIR instruments are inferior to dispersive or monochromator based NIR instruments.
More informationINSTRUMENTATION BREADBOARDING (VERSION 1.3)
Instrumentation Breadboarding, Page 1 INSTRUMENTATION BREADBOARDING (VERSION 1.3) I. BACKGROUND The purpose of this experiment is to provide you with practical experience in building electronic circuits
More informationMASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science
Student Name Date MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science 6.161 Modern Optics Project Laboratory Laboratory Exercise No. 6 Fall 2010 Solid-State
More information