M1 line User manual M.I.U.M1-3/03.01 Cod. J AM1 IE

Size: px
Start display at page:

Download "M1 line User manual M.I.U.M1-3/03.01 Cod. J AM1 IE"

Transcription

1 Temperature Controller / 6 DIN - 48 x 48 ASCON spa ISO 900 Certified M line c User manual M.I.U.M-3/03.0 Cod. J AM IE C UL US LISTED ASCON spa 00 Bollate (Milano) Italy via Falzarego, 9/ Tel Fax sales@ascon.it

2 Temperature Controller / 6 DIN - 48 x 48 M line c C UL LISTED US AT

3 information c NOTES ON ELECTRIC SAFETY AND ELECTROMAGNETIC COMPATIBILITY. Please, read carefully these instructions before proceeding with the installation of the controller. Class II instrument, real panel mounting. This controller has been designed with compliance to: Regulations on electrical apparatus (appliance, systems and installations) according to the European Community directive 73/3/EEC amended by the European Comunity directive 93/68/EEC and the Regulations on the essential protection requirements in electrical apparatus EN600- : 93 + A:95. Regulations on Electromagnetic Compatibility according to the European Community directive n089/336/eec, amended by the European Community directive n 9/3/EEC, 93/68/EEC, 98/3/EEC and the following regulations: Regulations on RF emissions EN : 00 residential environments EN : 00 industrial environments Regulation on RF immunity EN : 00 industrial equipment and system It is important to understand that it s responsibility of the installer to ensure the compliance of the regulations on safety requirements and EMC. The device has no user serviceable parts and requires special equipment and specialised engineers. Therefore, a repair can be hardly carried on directly by the user. For this purpose, the manufacturer provides technical assistance and the repair service for its Customers. Please, contact your nearest Agent for further information. All the information and warnings about safety and electromagnetic compatibility are marked with the B sign, at the side of the note.

4 Table of contents TABLE OF CONTENTS INSTALLATION...Page 4 ELECTRICAL CONNECTIONS...Page 8 3 PRODUCT CODING...Page 4 4 OPERATIONS...Page 8 5 AUTOMATIC TUNE...Page 8 6 TECHNICAL SPECIFICATIONS...Page 9 Resources Operating mode Control Alarms Retransmission Main universal input PV OP PV 0 Indication OP OP OP4 only OP Single OP OP OP4 action Single OP OP OP4 action M OP4 Setpoint (option) Modbus RS485 Parameterisation Supervision Fuzzy tuning with automatic selection One shot Auto tuning One shot Natural frequency 3

5 - Installation INSTALLATION. GENERAL DESCRIPTION Installation must only be carried out by qualified personnel. IP 0 Termination Unit EN600 - (IEC00 - ) Before proceeding with the installation of this controller, follow the instructions illustrated in this manual and, particularly the installation precautions marked with the B symbol, related to the European Community directive on electrical protection and electromagnetic compatibility. Panel surface B To prevent hands or metal touching parts that may be electrically live, the controllers must be installed in an enclosure and/or in a cubicle. Product code label Mounting clamps Sealing front panel gasket Front panel IP65 protection EN (IEC 59) 4

6 - Installation. DIMENSIONAL DETAILS.3 PANEL CUT-OUT 48 mm.89 in 65 mm min.56 in min 48 mm.89 in 0 mm max 0.79 in max mm in 65 mm min.56 in min mm in 0 mm 4.7 in 5

7 - Installation.4 ENVIRONMENTAL RATINGS B Operating conditions M T %Rh Altitude up to 000 m Temperature 0 50 C Relative humidity 5 95 % non-condensing Special conditions M T Altitude > 000 m Temperature >50 C %Rh Humidity > 95 % Suggestions Use 4V~ supply version Use forced air ventilation Warm up P Conducting atmosphere Use filter Forbidden Conditions D C E Corrosive atmosphere Explosive atmosphere 6

8 - Installation.5 PANEL MOUNTING [].5. INSERT THE INSTRUMENT Prepare panel cut-out Check front panel gasket position 3 Insert the instrument through the cut-out.5. INSTALLATION SECURING Position the mounting clamps Push the mounting clamps towards the panel surface to secure the instrument.5.3 CLAMPS REMOVING Insert the screwdriver in the clips of the clamps Rotate the screwdriver UL note [] For Use on a Flat Surface of a Type and Type 3 raintight Enclosure INSTRUMENT UNPLUGGING B Push and pull to remove the instrument Electrostatic discharges can damage the instrument Before removing the instrument the operator must discharge himself to ground MΩ 7

9 - Electrical connections ELECTRICAL CONNECTIONS L N OP TC ma mv NO C B b RTD A RS485 (OP4) OP - L 8V OUT F AM N/C N/C NO C N/C N/C OP - R. TERMINATION UNIT [] B ,5 Nm Rear terminal cover 5.7 mm 0. in Cable size mm 8 AWG UL note [] Use 60/70 C copper (Cu) conductor only. 4 screw terminals Option terminals Holding screw 0.5 Nm Positive screw driver PH Negative screw driver 0,8 x 4 mm Terminals Ø L Pin connector q.4 mm in max Fork-shape AMP Ø 5.5 mm - 0. in Stripped wire L 5.5 mm - 0. in 8

10 PRECAUTIONS B - Electrical wirings. PRECAUTIONS AND ADVISED CONDUCTOR COURSE B Despite the fact that the instrument has been designed to work in an harsh and noisy environmental (level IV of the industrial standard IEC 80-4), it is strongly recommended to follow the following suggestions. B A Conduit for supply and output cables B B A B A All the wiring must comply with the local regulations. L 7 L 7 N 8 N 8 The supply wiring should be routed away from the power cables. Avoid to use electromagnetic contactors, power relays and high power motors nearby. Avoid power units nearby, especially if controlled in phase angle Keep the low level sensor input wires away from the power lines and the output cables. If this is not achievable, use shielded cables on the sensor input, with the shield connected to earth. C E D C E D Conduit for low level sensor cables A = Supply B = Outputs C = Analog inputs D = Analogue output Serial communications E = SSR drive output 9

11 - Electrical connections.3 EXAMPLE OF WIRING DIAGRAM B.5 Ω external shunt resistor ma [3] Power supply switch mv Fuse A~T Fuse [5] Tc [6] Supply B V~ B V~ 3 OP 4 6 Supervision PTC [4] 5 Pt00 A RS485 8V OP RX/TX Retransmission 0P4 4 0mA 5 OP 6 [6] Notes: ] Make sure that the power supply voltage is the same indicated on the instrument. ] Switch on the power supply only after that all the electrical connections have been completed. 3] In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument. The power supply switch shall be easily accessible from the operator. 4] The instrument is is PTC protected. In case of failure it is suggested to return the instrument to the manufacturer for repair. 5] To protect the instrument internal circuits use: - A~ T fuses for Relay outputs - A~ T fuses for Triac outputs 6] Relay contacts are already protected with varistors. Only in case of 4 V ~ inductive loads, use model A D7 varistors (on request) PV wire transmitter 0

12 - Electrical connections.3. POWER SUPPLY B.3. OP OUTPUT B Switching power supply with multiple isolation and internal PTC Standard version: nominal voltage: 00-40V~ (- 5% + 0%) Frequency 50/60Hz Low Voltage version: Nominal voltage: 4V~ (- 5% + %) Frequency 50/60Hz or 4V (- 5% + 5%) Power consumption.6w max L N included PTC Supply A] Single relay output NO contact for resistive load of up to A / 50V~ max. Fuse A~ T (IEC 7) B] Triac Output NO contact for resistive load of up to A / 50V~ max. Fuse A~ T (IEC 7) Fuse Coil of the load contactor Fuse Coil of the load contactor 3 4 Varistor for inductive load 4V~ only 3 4 Varistor for inductive load 4V~ only.3.3 0P OUTPUT B A] SSR drive output, not isolated 0...5V, ±0%, 30mA max 0 Static relay Load B] Single relay output NO contact for resistive load of up to A / 50V~ max. Fuse A~ T (IEC 7) 5 6 Varistor for inductive load 4V~ only Fuse Coil of the load contactor

13 - Electrical connections OP OUTPUT B.3.4 OP4 OUTPUT (option) B OP output can be Relay (Std) or SSR drive. The jumper on the auxiliary board selects the output type: PV retransmission Galvanic isolation 500V~/ min. 0/4...0mA (750Ω or 5V max) ma 7 8 Load Link Pins - for OP-Relay Link Pins -3 for OP-SSR drive Jumper 3 Auxiliary board.3.5 SERIAL COMMUNICATIONS (option) B Galvanic isolation 500V~/ min Compliance to the EIA RS485 standard for Modbus/Jbus A Please, read: gammadue and deltadue controller series serial communication and configuration 7 8 RX TX

14 - Electrical connections.3.6 PV CONTROL INPUT B Connect the wires with the polarity as shown Use always compensation cable of the correct type for the thermocouple used The shield, if present, must be connected to a proper earth. For L J K S T thermocouple type 5 6 wire resistance 50Ω max For ma, mv and V mv ma External Shunt.5Ω 5 6 Rj >0MΩ If a 3 wires system is used, use always cables of the same diameter (mm min.) (line 0 Ω/lead maximum resistance) When using a wires system, use always cables of the same diameter (,5mm min.) and put a jumper between terminals 5 and 6 A When the distance between the controller and the sensor is 5 mt. using a cable of.5 mm diameter, produces an error on the measure of C. For PT00 resistance thermometer B 5 B A For 3 wires only. Maximum resistance/line 0 Ω For T ( x RTD Pt00) Special A R B R A 5 6 Use wires of the same length and.5 mm size. Maximum resistance/line 0 Ω R + R must be < 30Ω 6 With wire transducer PV Transducer With 3 wire transducer PV Transducer 4 0mA external shunt.5ω external shunt.5ω 8V 8V 3

15 3 - Product coding 3 PRODUCT CODING The complete code is shown on the instrument label. The informations about product coding are accessible from the front panel by mean of a particular procedure described at section 4.. page 9 AT 3000 Instrument label P/N ; M CONF : 00 S/N : A0A-9809/003 V~(L-N).85 64V 50/60 Hz -,6W B C D Basic product code (hardware) L M N Configuration code (software) 4

16 3 - Product coding 3. MODEL CODE The product code indicate the specific hardware configuration of the instrument, that can be modified by specialized engineers only. Line Basic Accessories Configur. Model: M A B C D - 0 F G 0 / I L M N Line M Power supply A 00-40V~ (- 5% + 0%) 3 4V~ (- 5% + %) or 4V (- 5% + 5%) 5 OP Output B Relay 0 Triac 3 Serial Communications Options C D None 0 0 Not fitted Transmitter Power Supply (P.S.) 0 6 Transmitter P.S. + Retransmission 0 7 RS485 None 5 0 Modbus/Jbus protocol Transmitter Power Supply 5 6 User manual F Italian/English (std) 0 French/English German/English Spanish/English 3 Front panel colour G Dark (std) 0 Beige 5

17 3 - Product coding 3. CONFIGURATION CODING The configuration code consists of 4 digits that identify the operating characteristic of the controller, as chosen by the user. Section 4.5 at pag. 6 reports the instructions how to set a new configuration code. I L M N 00 The configuration code can be displayed on the front panel, following the instructions at pag 9 section 4... Input type and range I TR Pt00 IEC C F 0 TR Pt00 IEC C -38 F TC L Fe-Const DIN C 3 F TC J Fe-Cu45% Ni IEC C 3 F 3 TC T Cu-CuNi C F 4 TC K Cromel -Alumel IEC C 3 9 F 5 TC S Pt0%Rh-Pt IEC C 3 9 F 6 DC input 0 50 mv, linear engineering units 7 DC input 0 50 mv, linear engineering units 8 Custom input and range 9 Control mode P.I.D. On - Off alarms indicator Output configuration Control OP / alarm AL on OP Control OP / alarm AL on OP Control OP / alarm AL on OP Control OP / alarm AL on OP Alarm AL on OP/ alarm AL on OP Alarm AL on OP/ alarm AL on OP Type of control and safety Reverse (AL active low) Safety 0% Direct (AL active high) Safety 0% Reverse (AL active low) Safety 00% Direct (AL active high) Safety 00% L M 0 3 6

18 A If, when the controller is powered up for the first time, the display shows the following message AT Conf it means that the controller has not been configured yet. The controller remains in stand-by until the configuration code is set correctly (see chapter 4.6 pag 6). 3 - Product coding Alarm type and function N Not active 0 Sensor break alarm Absolute active high active low 3 Deviation [] active high 4 active low 5 Deviation active out (of the band) 6 band [] active in (the band) 7 Note [] Choice not available when the controller has been configured as alarms indicator ( L digit assigned to 4 or 5) 7

19 4 - Operations 4 OPERATIONS 4. KEYPAD COMMANDS AND DISPLAY PV control input (operator mode) (in engineering units) when the measured value is greater than sensor high range Deviation indicator (SP-PV) Green led ON OK Green led ON + red led ON ±% ±% when the measured value is less than the sensor low range Code and/or value of the Parameter (programming mode) Only red led ON >% OP output ON (red) OP output ON (red) AT Tune running (green) Menu access Values modification Enter key for selection and value setting confirmation 8

20 4. DISPLAY When the display operation is selected, the controller presents automatically all the most important parameters and configuration information. During the operation, the parameters values cannot be modified by the user After sec from the end of the operation, the controller flashes the display and returns to the normal operating conditions. Note [] See page 7 [] This display is not presented if the instrument has been configured as an On - Off controller 4.. OF THE PROCESS VARIABLES Operator mode Engineering units [] Setpoint Control output [] 74.8 Unit s.p. Out after 0,5 sec. C Operations 4.. OF THE CONFIGURATION CODES Operator mode Engineering units [] Basic product code (see page 5) Configuration code (see page 6) Software release number 74.8 Unit Hard C 3000 Conf rel. after 0,5 sec A Example: M / Release 00A 9

21 4 - Operations 4.3 PARAMETER SETTING 4.3. NUMERIC ENTRY (i.e. the modification of the value of a stored Setpoint from 75.0 to 40.0) Press S or G momentarily to change the value of unit every push Continued pressing of S or G changes the value, at rate that doubles every second. Releasing the button the rate of change decreases. In any case the change of the value stops when it has reached the max/min limit set for the parameter lower 30.0 Operator mode Current setpoint display Setpoint modification raise 40.0 after sec Setpoint entry. The operation is acknowledged by one flash of the display.

22 4.3. MNEMONIC CODES SETTING (e.g. configuration see pages 6, 7) Press the S or G to display the next or previous mnemonic for the selected parameter. Continued pressing of S or G will display further mnemonics at a rate of one mnemonic every 0.5 sec. The mnemonic displayed at the time the next parameter is selected, is the one stored in the parameter. Unit C f 4 - Operations Engineering Units Degree Centigrade Degree Fahrenheit none no units defined f Degree Fahrenheit ph Ph

23 4 - Operations 4.4 PARAMETERIZATION AT 74.8 P 0 As.p st GROUP AL alarm threshold [] (see pag. 4) Parameter menu selection Values modification Modification/ Selection enter A The parameter setting procedure has a timeout. If no keys are pressed for, at least, 30 seconds, the controller switches back, automatically, to the operator mode. After having selected the parameter or the code, press S and G to display or modify the value (see pag. 0) The value is entered when the next parameter is selected, by pressing the R key. Pressing the Q key, the next group of parameters is presented on the display. PASS 5000 Back to the Operator mode OK Password entry only if Code value 5000 (see pages 6 7) Code entry from 5000 to 9999 Must be equal to the value of the parameter Code NO YES Note [] It is presented only if the controller has been configured with alarms. Digit L of the configuration code is assigned to 4 or 5 [] It is not presented if the controller has been configured with alarm n not active or of sensor break type. Digit N of the configuration code is assigned to 0 or. P 0 As.p P 5:0 p.b. P 5:0 t.i. P :00 t.d. P 0 t.c. AL alarm threshold [] (see pag. 4) Proportional band (PID algorithm only) % of span Integral time (PID algorithm only) 0ff / min. Derivative time (PID algorithm only) 0ff / min. Cycle time (Time proportioning only) sec.

24 4 - Operations PARAMETER MENÙ tune nd GROUP Tune run/stop (PID algorithm only) pass Password entry only if Code value <5000 (see pages 6 7) P :00 O.C. P00:0 Op. H P 0:5 hy. Back to the st parameter group Overshoot control (PID algorithm only) Control output high limit (PID algorithm only) % Control output hysteresis (On-Off control only) % of span P Off sl. u P Off sl. d PIn.sPcala PL. rpange s.p. l PF.sPcala PH. rpange s.p. H P 0:5 AIhy P 0:5 Ahy Setpoint ramp up (not available with alarms) 0ff/ digit/min Setpoint ramp down (not available with alarms) 0ff/ digit/min Setpoint low limit (not available with alarms) low range s.p. H Setpoint high limit (not available with alarms) s.p. l high range AL hysteresis % of the span [] AL hysteresis % of the span [] P Off t.fil P 0 In.sh P Addr PIn.sPcala PL. rpange rt.lo PF.sPcala PH. rpange rt.hi Back to the st parameter of the nd group Direct access to the configuration (pages 6 7) Filter time constant Off/...30 sec. Input shift Off/ digits Communication address (if option installed) 0ff/ 47 Retransmission low range (if option installed) full scale Retransmission high range (if option installed) full scale 3

25 4 - Operations 4.5 PARAMETER st GROUP The controller parameters have been organized in group, according to their functionality area. #AIs.p AL alarm threshold The threshold is presented only if the controller have been configured with alarms. ( Digit L of the configuration code assigned to 4 or 5) #As.p AL alarm threshold The alarm occurrences handle the OP and OP outputs, in different ways, according to the configured types of alarms, as illustrated. #p.b. Proportional band This parameter specifies the proportional band coefficient that multiplies the error (SP - PV) Integral #t.i. time It is the integral time value, that 4 Sensor break or input disconnection Sensor T Visualisation Absolute alarm (full scale) On Off hy low range Alarm threshold Deviation alarm SP On Off hy - low range Alarm threshold Band alarm SP On Off full scale hy hy alarm threshold On Off over-range under-range Active high Active low high range On Off Active high Active low + high range full scale On Off Active out Active in specifies the time required by the integral term to generate an output equivalent to the proportional term. When Off the integral term is not included in the control algorithm. #t.d. Derivative time It is the derivative term coefficient that specifies the time required by the proportional term P to reach the level of D. When Off the derivative term is not included in the control algorithm. #t.c. Control output cycle time It s the cycle time of the time proportioning control output. The PID control output is provided through the pulse width modulation of the digital waveform. #O.C. Overshoot control This parameter specifies the span of action of the overshoot control. Setting lower values (0.99 > 0.0) the overshoot generated by a Setpoint change is reduced. The overshoot control doesn t affect the

26 effectiveness of the PID algorithm. Setting, the overshoot control is disabled. #Op. H Control output high limit It specifies the maximum value the control output can be set #hy. Control output hysteresis Hysteresis of the threshold Off SP hy Control output hysteresis span, set in % of the full scale. nd GROUP #sl. u #sl. d On Setpoint ramp up Setpoint ramp down This parameter specifies the maximum rate of change of the Setpoint in digit/min. When the parameter is Off, this function is disabled. #s.p. l Setpoint low limit Low limit of the setpoint value. When the parameter is Off, this function is disabled. #s.p. H Setpoint high limit High limit of the setpoint value. When the parameter is Off, this function is disabled. #AIhy #Ahy AL alarm hysteresis AL alarm hysteresis Hysteresis of the threshold of both the alarms, that activate OP and OP control output. It is specified as a % of the full scale. #t.fil Input filter time constant Time constant, in seconds, of the RC input filter applied to the PV input. When this parameter is set to Off the filter is bypassed. Filter response 00% 63,% 0 t.fil #In.sh Input shift 4 - Operations This value is added to the measured PV input value. Its effect is to shift the whole PV scale of up to ± 60 digits. #Addr Controller address the address range is from to 47 and must be unique for each controller on the communication bus to the supervisor. When set to Off the controller is not communicating #rt.lo #rt.hi PV Time Retransmission low range Retransmission high range These parameters define the range of the OP4 retransmission output. Example: 4..0 ma output corresponding to 0 0 C. 5

27 4 - Operations 4.6 CONFIGURATION The configuration of the controller is specified through a 4 digit code that defines the type of input, of control output and of the alarms. (sect. 3. pag6) Other parameters specifie the type of auxiliary functions. AT Operator mode 74.8 PASS 5000 NO OK Password entry only if Code value 5000 Code entry from 5000 to 9999 Must be equal to the value of the parameter Code YES CONFIGURATION MENU st GROUP AIs.p Parameter menu selection Values modification Modification/ Selection enter Press S or G to display the next parameter or the next code and change its value. The new value entered is stored into the controller when the next parameter is selected by pressing R. baud retr Code Baude rate (only if comm. is installed) 00/ /9600 Retransmission range (only if present) 0=0 / 4=0 ma Password (33 default from factory) sc.lo sc.hi prot Low range [] (linear scale only) High range [] (linear scale only) Communication protocol (only if communication is installed) M.bu5 / jbus 6

28 I nd GROUP tune Entry of digits I-L-M-N of the configuration code (chapter 3. page 6) L M N 00 Engineering units (see table) N of decimals (linear scale only) 0 3 Conf Unit sc.d.d pass 33 YES OK Password entry only if Code value <5000 Code entry from 0 to 4999 (33 default from factory) The entered password must correspond to the one store in the Code parameter. NO A If the controller has not been configured Conf is shown on the front panel at the power up. In this situation, the controller has its outputs and inputs not active. This situation ends when a correct configuration code is entered. 4 - Operations Note Pressing the Q the next group of parameters is displayed. [] Table of the supported Engineering Units. Centigrade degrees * C Fahrenheit degrees * f none mv Volt ma Ampere Bar PSI Rh ph none nu U MA A bar psi rh ph * For inputs from thermocouple or resistance thermometer, the choice is between C and F only. [] Range of min 00 digits. 7

29 5 - Automatic tune 5 AUTOMATIC TUNE Start/stop of the Fuzzy Tuning The Tuning operation can be started or stopped any time tune stop strt Operator mode press until To start select strt To stop select stop The green led 3 goes on when the Fuzzy Tuning is in progress. At the end of this operation, the calculated PID terms parameter are stored and used by the control algorithm and the controller goes back to the operator mode. The green led 3 becomes off. This function allows the calculation of the optimal PID terms parameters, monitoring the response of the process to disturbances. The controller provides types of one shot tuning algorithm, that are selected automatically according to the process condition when the operation is started. Step response This type is selected when, at the start of the autotune operation, the PV is far from the Setpoint of more than 5% of the span. This method has the big advantage of fast calculation, with a reasonable accuracy in the term calculation. Natural frequency This type is selected when the PV is close to the SP setpoint. This method has the advantage of a better accuracy in the term calculation with a reasonable speed calculation. The Fuzzy Tuning determines automatically the best method to use to calculate the PID term, according the process conditions. Step response Setpoint change PV variable Control output SP Natural frequency tuning start PV variable Control output End of the tuning operating and setting of the new calculated terms. Start of autotune operation End of the tuning operating and setting of the new calculated terms.

30 6 TECHNICAL SPECIFICATIONS Features (at 5 C enviromental temp.) Total configurability see par. 3. pag. 6 par. 4.6 pag. 6 PV Input (see pag.3 and pag. 6) 6 - Technical specification Description From keypad or serial communication the user selects: the type of input - the associated functions and the corresponding outputs - the type of control algorithm - the type of output and the safe conditions - the type and functionality of the alarms - the values of all the control parameters. A/D converter with resolution of points Common Update measurement time: 0. seconds Sampling time: 0.5 seconds characteristics Input bias: digit Input filter with enable/disable: 30 seconds Accuracy Resistance thermometer Thermocouple DC input (current) DC input (voltage) 0.5% ± digits for temperature sensors 0.% ± digits (for mv and ma) Pt00Ω at 0 C (IEC 75) C/ Fselectable L,J,T,K,S (IEC 584) C/ F selectable 4 0mA,0-0mA with external shunt.5ω Rj >0MΩ 0 50mV, 0-50mV Rj >0MΩ or 3 wires connection Internal cold junction compensation in C/ F Engineering units Conf. decimal point position Init. Sc Full Sc (min. range of 00 digits) Between 00 40V~ the error is minimal Max. wire Res: 0Ω max (3 wires) Sensitivity: 0.35 C/0 Env. Temp. <0.35 C / 0Ω Wire Res. Max. wire Res.: 50Ω max Sensitivity: <µv/ C Env. Temp. <5µV / 0Ω Wire Res. Input drift: <0.% / 0 C Env. Temp. Error indicator By led with green led when error <% (see page 8) 9

31 6 - Technical specification Features (at 5 C enviromental temp.) Operating mode and Outputs Control mode OP output OP output AL alarm (indicator with alarms) AL alarm Description AL alarm AL alarm Indicator with alarms OP - Relay or Triac OP - SSR drive or Relay OP - SSR drive or Relay OP - Relay or Triac Control output AL alarm PID loop or ON-OFF OP - Relay or Triac OP - SSR drive or Relay loop with Alarm OP - SSR drive or Relay OP - Relay or Triac Algorithm PID with overshoot control or ON OFF Proportional band (P) % Integral time (I) min OFF = O Derivative time (D) min PID algorithm Cycle time 00 sec Overshoot control High limit % Hysteresis % ON-OFF algorithm SPST Relay N.O., A/50V~ for resistive load Triac, A/50V~ for resistive load SSR drive, not isolated: 5V, ± 0%, 30mA max SPST Relay N.O., A/50V~ for resistive load Hysteresis 0. 0,0% full scale Active high Active low Absolute threshold: full scale Hysteresis 0. 0,0% c.s. Active high Deviation threshold ±range Action Active low Action type band threshold 0 range Absolute threshold whole range Special function Sensor break 30

32 6 - Technical specification Features (at 5 C enviromental temp.) Setpoint OP4 PV retransmission (option) One shot Fuzzy-Tuning with automatic selection Serial comm. (option) Auxiliary Supply Operational safety General characteristics Description Ramp up and down. User inhibited Low limit High limit Galvanic isolation: 500 V~/ min Resolution bit (0.05%) Accuracy: 0. % The controller selects automatically the best method according to the process conditions digit/min (OFF = 0) From low range to the high limit From low limit to the high range Current output: 0/4 0mA 750Ω/5V max Step method Natural frequency method RS485 isolated, Modbus/Jbus protocol, 00, 400, 4800, 9600 bit/sec wires +8V ±0%, 30mA max for an external transmitter supply Measure input Control output Parameters Access protection Detection of out of range, short circuit or sensor break with automatic activation of the safety strategies and alerts on display Safety value: 0 +00%. (user enabled/disabled) parameter and configuration data are stored in a non volatile memory for an unlimited time Password to access the configuration and parameters data 00-40V~ (- 5% + 0%) 50/60Hz Power supply or 4V~ (- 5% + %) 50/60Hz and 4V (- 5% + 5%) Power consumption.6w max Electric safety Compliance to EN600, installation class (500V) pollution class Electromagnetic compatibility Compliance to the CE standards for industrial system and equipment UL and cul Omologation File 7645 IP0 termination unit Protection EN65059 IP65 front panel Dimensions / 6 DIN - 48 x 48, depth 0 mm, weight 30 gr. apx. 3

33 Guarantee WARRANTY We warrant that the products will be free from defects in material and workmanship for 3 years from the date of delivery. The warranty above shall not apply for any failure caused by the use of the product not in line with the instructions reported on this manual. G.&P. Grafica & Pubblicità Gazzaniga (BG) G&P@mail. csg-net. it 3

34 ASCON S WORLDWIDE SALES NETWORK SUBSIDIARY FRANCE ASCON FRANCE Phone Fax AGENCE SUD-EST Phone Fax AGENCE RÉGION-EST Phone Fax DISTRIBUTORS ARGENTINA MEDITECNA S.R.L. Phone Fax AUSTRALIA IPA INDUSTRIAL PYROMETER (AUST) PTY.LTD Phone Fax FINLAND & ESTONIA TIM-TOOL OY Phone Fax GERMANY MESA INDUSTRIE ELEKTRONIK GMBH Phone Fax GREECE CONTROL SYSTEM Phone Fax BRANCH OFFICE Phone Fax HOLLAND TEMPCONTROL I.EP. B.V. Phone Fax PORTUGAL REGIQUIPAMENTOS LDA Phone Fax SPAIN INTERBIL S.L. Phone Fax BRANCH OFFICES Phone Fax Phone Fax SWITZERLAND CONTROLTHERM GMBH Phone Fax TURKEY KONTROL SISTEMLERI LTD Phone Fax UNITED KINGDOM EUKERO CONTROLS LTD Phone Fax

C1 line User manual M.I.U.C1-3/03.01 Cod. J AC1 IE

C1 line User manual M.I.U.C1-3/03.01 Cod. J AC1 IE Controller Indicator Transmitter 1 / 32 DIN - 48 x 24 ASCON spa ISO 9001 Certified C1 line c User manual M.I.U.C1-3/03.01 Cod. J30-478-1AC1 IE C UL US LISTED ASCON spa 20021 Bollate (Milano) Italy via

More information

C10 line User manual M.I.U.C10-1/02.06 Cod. J AC1 SEA

C10 line User manual M.I.U.C10-1/02.06 Cod. J AC1 SEA Controller Indicator Transmitter 1 / 32 DIN - 48 x 24 C10 line c User manual M.I.U.C10-1/02.06 Cod. J30-478-1AC1 SEA C UL US LISTED ATHENA CONTROLS, INC. 5145 Campus Drive Plymouth Meeting PA 19462 U.S.A.

More information

C1 line User manual M.I.U.C1-4/04.05 Cod. J AC1 IE

C1 line User manual M.I.U.C1-4/04.05 Cod. J AC1 IE Controller Indicator Transmitter 1 / 32 DIN - 48 x 24 ASCON spa ISO 9001 Certified C1 line c User manual M.I.U.C1-4/04.05 Cod. J30-478-1AC1 IE C UL US LISTED ASCON spa via Falzarego, 9/11 20021 Bollate

More information

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

DIN rail mounting temperature controller with current transformer input deltadue series D1 line BT.. D/E S E R I E S DIN rail mounting temperature controller with current transformer input deltadue series D line The controller with load control The deltadue series includes a powerful DIN rail mounting

More information

Temperature Controller

Temperature Controller Temperature Controller 1/8 IN - 48 x 96mm Platinum Series X400 Line Cost Effective Solutions This 48x96mm size controller of the Platinum Series, provides a high degree of functionality and reliability

More information

M3 line User manual M.I.U.M3-4/03.01 Cod. J AM3 IE

M3 line User manual M.I.U.M3-4/03.01 Cod. J AM3 IE Temperature Controller 1 / 16 DIN - 48 x 48 ASCON spa ISO 9001 Certified M line c User manual M.I.U.M -4/0.01 Cod. J0-478-1AM IE C UL US LISTED ASCON spa 20021 Bollate (Milano) Italy via Falzarego, 9/11

More information

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line BT. 2.9 M/E Process controller programmer /6 DIN - 48 x 48 mm gammadue series M line Advanced features, customizable and process adaptable High speed data aquisition and signal management. Efficent information

More information

DIN rail mounting dual loop controller/ analogue acquisition module

DIN rail mounting dual loop controller/ analogue acquisition module E D2 line User manual Table of contents - Resources - Operating modes - Model code - Table and description of standard parameters - Technical specifications - Commands - Communications parameters reset

More information

Process controller with Modbus Master/Slave & PROFIBUS DP 1/8 DIN - 48 x 96 mm Platinum Series X5000 Line

Process controller with Modbus Master/Slave & PROFIBUS DP 1/8 DIN - 48 x 96 mm Platinum Series X5000 Line Process controller with Modbus Master/Slave & PROFIBUS DP /8 DIN - 8 x 96 mm Platinum Series X000 Line Sophisticated multifunction process controller with high level communications By its three different

More information

M3 line User manual M.I.U. M3-6/09.06 Cod. J AM3 FE

M3 line User manual M.I.U. M3-6/09.06 Cod. J AM3 FE Temperature Controller 1 / 16 DIN - 48 x 48 ISO 9001 Certified M line User manual M.I.U. M -6/09.06 Cod. J0-478-1AM FE c Ascon Tecnologic srl via Indipendenza 56, 27029 Vigevano (PV) Tel.: +9-081 69 871

More information

/1 IM-UK323-01

/1 IM-UK323-01 3231365/1 IM-UK323-01 UK-Issue 1 SX27 Series Process Controller Installation and Maintenance Instructions c 1 2 3 274.8 RUN SP2 MAN 275.0 Introduction Installation Electrical Connections Operations Displays

More information

Double action controller with analogue output 1/4 DIN - 96 x 96 mm gammadue series Q3 line

Double action controller with analogue output 1/4 DIN - 96 x 96 mm gammadue series Q3 line BT.. Q/E ouble action controller with analogue output / IN - 9 x 9 mm gammadue series Q line C UL LISTE US Analogue control within everyone s reach Including Auto/Man selection and digital inputs for external

More information

D1 line. D1 line User Manual M.I.U. D1-2/04.05 Cod. J AD1 IE OP1 OP2. (option) OP3. Model code. Configuration. Serial communications

D1 line. D1 line User Manual M.I.U. D1-2/04.05 Cod. J AD1 IE OP1 OP2. (option) OP3. Model code. Configuration. Serial communications E D line User manual ASCON spa ISO 9 certified DIN-rail mounting temperature controller with current transformer input D line S E R I E S User Manual M.I.U. D-2/. Cod. J3-78-AD IE C c UL LISTED US Table

More information

Process controller with PROFIBUS DP and Modbus Master/Slave 1/4 DIN - 96 x 96 mm gammadue series Q5 line

Process controller with PROFIBUS DP and Modbus Master/Slave 1/4 DIN - 96 x 96 mm gammadue series Q5 line BT. 2.3 Q/E Process controller with PROFIBUS DP and Modbus Master/Slave / DIN - 96 x 96 mm gammadue series Q line Sophisticated multifunction process controller with high level communications By its three

More information

X1 line User Manual M.I.U.X1-6/09.02 Cod. J AX1 IE

X1 line User Manual M.I.U.X1-6/09.02 Cod. J AX1 IE Heat / Cool temperature controller 1 / 8 DIN - 48 x 96 ISO 9001 Cer tifi e d X1 line User Manual M.I.U.X1-6/09.02 Cod. J30-478-1AX1 IE c Ascon Tecnologic srl viale Indipendenza 56, 27029 Vigevano (PV)

More information

Double action controller with analogue output 1/8 DIN - 48 x 96 mm gammadue series X3 line

Double action controller with analogue output 1/8 DIN - 48 x 96 mm gammadue series X3 line BT.. X/E ouble action controller with analogue output /8 IN - 8 x 9 mm gammadue series X line Analogue control within everyone s reach Including Auto/Man selection and digital inputs for external activation

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

N1040i Indicator. UNIVERSAL INDICATOR INSTRUCTIONS MANUAL V1.0x D PRESENTATION FEATURES

N1040i Indicator. UNIVERSAL INDICATOR INSTRUCTIONS MANUAL V1.0x D PRESENTATION FEATURES UNIVERSAL INDICATOR INSTRUCTIONS MANUAL V1.0x D PRESENTATION N1040i is a quite versatile process indicator. With a wide list of input types - thermocouples, thermo-resistance, voltage and current the N1040i

More information

DC1010/DC1020/DC1030/DC1040

DC1010/DC1020/DC1030/DC1040 05/0 0-10-10-0-EN Page 1 of DC1010/DC1020/DC100/DC1040 DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of functionality and

More information

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification 01 May 20 30-10-10--EN Page 1 of DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition UNICONT PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1 ST edition pmg4111a0600p_01 1 / 24 TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 3 2. ORDER CODE... 3 3. TECHNICAL DATA...

More information

Temperature Measurement

Temperature Measurement Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

MPS SERIES. INSTALLATION and TECHNICAL MANUAL MPS 4 MPS 5 MPS 9 4 PV

MPS SERIES. INSTALLATION and TECHNICAL MANUAL MPS 4 MPS 5 MPS 9 4 PV MPS SERIES INSTALLATION and TECHNICAL MANUAL PV AT M AL1 AL2 SP1 4 PV AT SV SV M SP1 SP2 AL1 AL2 AL3 P SP2 P MPS 4 MPS 5 PV M AL1 SV AT SP1 AL2 SP2 AL3 P MPS 9 ITALMEC ELETTRONICA P.O. Box 34 40069 ZOLA

More information

- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER

- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER MULTI - FUNTION ONTROLLERS - SMART TUNE - PID ONTROL - UNIVERSAL, 3 WIRE - T, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER WITH POTENTIOMETER FEEDBAK -

More information

Digital indicator for panel mounting With multi-function input Model DI25

Digital indicator for panel mounting With multi-function input Model DI25 Accessories Digital indicator for panel mounting With multi-function input Model DI25 WIKA data sheet AC 80.02 Applications Plant construction Machine tools Plastics technology and processing Ventilation

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

AK48 SPECIFICATIONS APPLICATIONS GENERALS FEATURES. 1/16 DIN Process controller

AK48 SPECIFICATIONS APPLICATIONS GENERALS FEATURES. 1/16 DIN Process controller /6 DIN Process controller AK48 Three control types The user can select among three different control actions: ON/OFF, PID or PID ( PI with automatic derivative action). PID and PID include two differente

More information

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R 170.ADD.LFS.RB0 0,8.011-98/B r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R INDEX ASSEMBLING... 1 Warning... 1 General assembling information... 1 Wall mounting... 1 Omega din rail mounting... 2 MECHANICAL

More information

Temperature measurement TMD 832 head transmitter

Temperature measurement TMD 832 head transmitter Technical information TI 062R/09/en Mat.-Nr. 510 00782 Temperature measurement TMD 832 head transmitter SMART head transmitter with HART protocol for RTD, Thermocouple and mv input signals Applications

More information

K3P ENG.qxd 23/10/ Pagina 1

K3P ENG.qxd 23/10/ Pagina 1 K3P ENG.qxd 23/10/2003 12.30 Pagina 1 - CLEAR PROGRAM STATUS DISPLAY - DIRECT PROGRAM PARAMETER ADJUSTMENT - 8 INDEPENDENT PROGRAMS - 10 SEGMENTS FOR EACH PROGRAM - "SET - POINT TRACKING " AND "GUARANTEED

More information

APPENDIX APPENDIX A 1

APPENDIX APPENDIX A 1 A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

8003 1/8 DIN Temperature Controller

8003 1/8 DIN Temperature Controller 8003 1/8 DIN Temperature Controller Issue Date April 1994 USER S MANUAL 0037-75212 Contents Model Identification... Page ii Dimensions and Panel Cutout...1 Wiring...2 Hardware Setup...3 Configuration Mode...4

More information

Excellent low-cost Process & Temperature Controllers

Excellent low-cost Process & Temperature Controllers C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200

More information

TEMPERATURE CONTROLLER. MOUNTED ON A 35 mm RAIL RE60 TYPE USER S MANUAL

TEMPERATURE CONTROLLER. MOUNTED ON A 35 mm RAIL RE60 TYPE USER S MANUAL TEMPERATURE CONTROLLER MOUNTED ON A 35 mm RAIL RE60 TYPE USER S MANUAL 1 2 Contents 1. Application... 5 2. Controller set... 5 3. Preparing the controller for opereation... 6 3.1. Security... 6 3.2. Controller

More information

TEMPERATURE CONTROLLER RE55 TYPE USER S MANUAL

TEMPERATURE CONTROLLER RE55 TYPE USER S MANUAL TEMPERATURE CONTROLLER RE55 TYPE USER S MANUAL CONTENTS 1. APPLICATION...5 2. CONTROLLER SET...5 3. CONTROLLER PREPARATION to WORK...5 3.1. Safety...5 3.2. Controller installation in the panel...6 3.3.

More information

TEMPERATURE CONTROLLER 48 x 48 mm RE70 TYPE USER S MANUAL

TEMPERATURE CONTROLLER 48 x 48 mm RE70 TYPE USER S MANUAL TEMPERATURE CONTROLLER 48 x 48 mm RE70 TYPE USER S MANUAL 1 RE70-09 User's Manual 2 Contents: 1. Application... 3 2. Controller set... 3 3. Basic requirements, operational safety... 3 4. Installation...

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

Temperature Transmitter ZTT series

Temperature Transmitter ZTT series BT.11.13 ZT/I ZTT series The ZTT series transmitter accepts the most commonly used temperature sensors (RTD, T/C) as well as mv and slide wire signals. All the models adopt a 2 wire 4...20mA output signal

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright

More information

7SD/7SH/7SM Temperature Controllers

7SD/7SH/7SM Temperature Controllers 7SD/7SH/7SM Temperature ADVANTAGE EZ Series 7SD, 7SH, 7SM 1/16 DIN Temperature 3Digit LED Display Thermocouple and RTD Input Autotuning NEMA 4X Field onfigurable 100 to 40 Vac Switching Power Supply Programmable

More information

ITP16. Temperature indicator. User guide

ITP16. Temperature indicator. User guide ITP16 Temperature indicator User guide ITP16_2018.05_0280_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany Tel.: +49 (0) 511

More information

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External

More information

MICRO-CONTROLLER X (48 48 mm)

MICRO-CONTROLLER X (48 48 mm) PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature

More information

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched EXL6 OCS Datasheet for HE- EXL1E0, HE- EXL1E2, HE- EXL1E3, HE- EXL1E4, HE- EXL1E5, HE- EXL1E6 HEXT371C100, HEXT371C112, HEXT371C113, HEXT371C114, HEXT371C115, HEXT371C116 1. Specifications Required Power

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

MCR-T-UI(/NC) MCR-T-UI-E(/NC) MCR-T-UI(/) MCR-T-UI-E(/) Programmable Temperature Transducers for Resistance Thermometers and Thermocouples INTERFACE ata Sheet 00_0_en PHOENIX CONTACT - 0/00 escription A universal temperature measuring

More information

TEMPERATURE CONTROLLER RE21 TYPE

TEMPERATURE CONTROLLER RE21 TYPE TEMPERATURE CONTROLLER RE21 TYPE USER S MANUAL 1 2 Contents 1. Application... 5 2. Controller set... 5 3. Preparation of the controller to work... 6 3.1. Safety... 6 3.2. Controller installation... 9 3.3.

More information

K Series. Controllers / mini-programmers with wattmeter function and independent timer

K Series. Controllers / mini-programmers with wattmeter function and independent timer USEFUL APPLICATIONS Shoemaking Machineries Glueing and binding machines (hot glue) Packaging and blister packing machines Paint booths T-shirt printing Climatic chambers and incubators Hot runner Glass

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Uni-Mux XQL Multi-Channel Data Acquisition Module

Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module * 8 channel differential inputs. * 16 channel single ended inputs. * User programmable via P.C. software.

More information

OVEN INDUSTRIES, INC. Model 5C7-362

OVEN INDUSTRIES, INC. Model 5C7-362 OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...

More information

Series Valve Temperature Controller. Instruction Sheet

Series Valve Temperature Controller. Instruction Sheet 2013/10/03 Series Valve Temperature Controller Instruction Sheet Thank you very much for choosing Delta DTV series valve temperature controller. Please read this instruction sheet before using your DTV

More information

High-precision process calibrator Model CED7000

High-precision process calibrator Model CED7000 Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry

More information

Instructions for Tempco Control Enclosure PCM10001 through PCM10004

Instructions for Tempco Control Enclosure PCM10001 through PCM10004 Visionary Solutions for Industry Since 1972 ISO 9001 Certified Temperature Controllers & Sensors Heating Elements Process Heating Systems Instructions for Tempco Control Enclosure PCM10001 through PCM10004

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

CompoBus/D-type Digital Controller

CompoBus/D-type Digital Controller CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

ControlMaster CM10, CM30, CM50 Universal process controllers, 1 /8, 1 /4 and 1 /2 DIN

ControlMaster CM10, CM30, CM50 Universal process controllers, 1 /8, 1 /4 and 1 /2 DIN User Guide Standard Functionality IM/CM/S-EN Rev. B ControlMaster CM10, CM30, CM50 Universal process controllers, 1 /8, 1 /4 and 1 /2 DIN The Company We are an established world force in the design and

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional) Temperature Controller with Built-in SSR SB SB General Description SB is a channel temperature controller with Built-in SSR (Solid state relay) designed for flexible heating solutions such as heat trace

More information

6.6 Analog input module SM 331; AI 8 x 13 Bit; (6ES7331-1KF02-0AB0)

6.6 Analog input module SM 331; AI 8 x 13 Bit; (6ES7331-1KF02-0AB0) Order number 6ES7331-1KF02-0AB0 Properties 8 inputs in 8 channel groups Programmable resolution at each channel group (12 bits + sign) Programmable measurement type per channel group: Voltage Current Resistance

More information

General Specifications

General Specifications General Specifications Model UT, UT Temperature Controller GS CE-E GENERAL UT series temperature controllers provide only the functions and size you require for your application. /6 DIN sizes is available.

More information

Z170REG. Universal converter module with galvanic insulation between 2 analog outputs

Z170REG. Universal converter module with galvanic insulation between 2 analog outputs USER MANUAL EN Z170REG Z Line Universal converter module with galvanic insulation between 2 analog outputs Chapter index Page 1. Identification data 1 2. Preliminary warnings 2 3. Description and characteristics

More information

I/A Series Model 718TC 1/8 DIN Temperature Controller with ma Output

I/A Series Model 718TC 1/8 DIN Temperature Controller with ma Output Instruction MI 018-573 February 1997 I/A Series Model 718TC 1/8 DIN Temperature Controller with ma Output Foxboro and I/A Series are trademarks of The Foxboro Company. Siebe is a registered trademark of

More information

DIGEM f 96 x 48 EK. Applications. Description

DIGEM f 96 x 48 EK. Applications. Description 3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

Temperature head transmitter itemp PCP TMT 181

Temperature head transmitter itemp PCP TMT 181 Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

Thermocouple - Transducer

Thermocouple - Transducer Thermocouple - Transducer TM3 Characteristics: Thermocouple type J, K, R, S, T, E, B, N Linearity error < 1% Measurement range configurable -210...+1820 C Built-in cold junction compensation Galvanic 3-way

More information

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual TE200S Solid State Relays Two-phase control of three-phase loads User manual Copyright Eurotherm Automation 1998 All rights reserved. All reproduction or transmission in any form or using any procedure

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information

TC1028 series. Thyristor units. Control of single-phase resistive or inductive loads. User manual (300A to 500A rated units)

TC1028 series. Thyristor units. Control of single-phase resistive or inductive loads. User manual (300A to 500A rated units) TC1028 series Thyristor units Control of single-phase resistive or inductive loads User manual (300A to 500A rated units) Copyright Eurotherm Automation 1998 All rights reserved. All reproduction or transmission

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

Analogue Temperature Transmitter

Analogue Temperature Transmitter TE 19.01 Electrical Temperature Measurement Analogue Temperature Transmitter Configurable Ranges, Head Mounting for Pt100 Resistance Thermometers for Thermocouples Applications Plant construction Power

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

Instruction Manual (1/8 DIN) Controller With ma output.

Instruction Manual (1/8 DIN) Controller With ma output. Instruction Manual 31081 (1/8 DIN) Controller With ma output. 31081-0-00.p65 1 31081-0-00.p65 2 INDEX GB OUTLINE AND CUT OUT DIMENSIONS... IV REAR TERMINAL BLOCK... VI MOUNTING REQUIREMENTS... 1 CONNECTION...

More information

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.

More information

170.IU0.LFS.0B /B r USER MANUAL LFS

170.IU0.LFS.0B /B r USER MANUAL LFS 170.IU0.LFS.0B0 4.4-98/B r USER MANUAL LFS INDEX MOUNTING REQUIREMENTS... 1 OUTLINE AND CUT OUT DIMENSIONS... 2 CONNECTION DIAGRAMS... 3 PRELIMINARY HARDWARE SETTINGS... 9 CONFIGURATION PROCEDURE... 10

More information

TxBlock-USB Transmitter

TxBlock-USB Transmitter Transmitter TEMPERATURE TRANSMITTER - OPERATING MANUAL V1.0x I INTRODUCTION The TxBlock-USB is a 4-20 ma 2-wire temperature transmitter for head mount, powered by the current loop. The output current is

More information

Description of functions Controller system VR660 / A200R

Description of functions Controller system VR660 / A200R Description of functions Controller system VR660 / A00R Local bus RS VR660/A00R e 56 76-0.07 Camille Bauer AG Aargauerstrasse 7 CH-560 Wohlen/Switzerland Phone + 56 68 Fax + 56 68 5 5 e-mail: info@camillebauer.com

More information

2002-ALM USER MANUAL

2002-ALM USER MANUAL 00 - ALM DUAL TRIP AMPLIFIER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting from errors or omissions,

More information

RMA42. Technical Information

RMA42. Technical Information Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and

More information

P5201 Universal Programmable Transmitters with Galvanic Isolation

P5201 Universal Programmable Transmitters with Galvanic Isolation Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to

More information

Passive TX, 2 wires, ma 0/ mv, 0/1... 5V, 0/ V ma (active) Pt1000 Pt100 TC. 2.2 Inputs

Passive TX, 2 wires, ma 0/ mv, 0/1... 5V, 0/ V ma (active) Pt1000 Pt100 TC. 2.2 Inputs KRD3 CONTROLLER AND MINI-PROGRAMMER Engineering Manual Code: ISTR-MKRD3ENG00 - Vr. 0.0 (ENG) Ascon Tecnologic S.r.l. Viale Indipendenza 56, 27029 Vigevano (PV) - ITALY Tel.: +39 0381 69871/FAX: +39 0381

More information

Temperature Measurement

Temperature Measurement Temperature Measurement SITANS T00 Overview Application SITANS T00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical specifications - Installation rules - Electrical connections - Modbus connection rules - DIP-switches settings -

More information

DIGITAL PROGRAM CONTROLLER

DIGITAL PROGRAM CONTROLLER KP1000 SERIES DIGITAL PROGRAM CONTROLLER The KP1000 series is a 96x96mm digital program controller with the indicating accuracy of ±0.1%, the control cycle of approximately 0.1 seconds and maximum 19 program

More information

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 o RMS AC current or frequency measurements o Current auto range measurements up to 12 A o Frequency measurement range 16 400 Hz

More information

HAWK5000 Operators Manual

HAWK5000 Operators Manual HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED

More information

ISOMETER IRDH575. Approvals

ISOMETER IRDH575. Approvals Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation

More information