W7070A2000 ZAPP WIRELESS RECEIVER

Size: px
Start display at page:

Download "W7070A2000 ZAPP WIRELESS RECEIVER"

Transcription

1 HONEYWELL EXCEL 000 OPEN SYSTEM BEFORE INSTALLATION The Wireless Receiver (including the External Antenna) is capable of exchanging data with the following four types of room units: The RT00A00 Wireless Handheld Remote Control the T0A00 Wireless Wall Module with temperature sensor and setpoint; the T0A0 Wireless Wall Module with temperature sensor; and the T0B00 Wireless Wall Module for HAVC, light, and sunblind applications. The is suitable for use with up to eight rooms in which the aforementioned room units are in operation. The Wireless Receiver receives data from the room units at. MHz. WIRELESS RECEIVER INSTALLATION INSTRUCTIONS Communications The utilizes a free-topology transceiver (FTT0A) Link Power compatible LONWORKS network that allows daisy-chain, loop, and star network configurations or any combination thereof. Depending upon the LONWORKS network configuration used, one or two termination modules may be required (see Fig. 4). Different connections to the termination module are necessary, depending upon whether it is used in a single- or double-terminated network configuration. For more information, please see Mechanisms (ENB- 00GE). NOTE: The LONWORKS network is insensitive to polarity, eliminating installation errors due to miswiring STANDARDS AND NORMS The System complies with CE and EN and EN 0 4- as well as LONMARK Application Layer Guidelines Version.. IMPORTANT! It is recommended that devices be kept at room temperature for at least 4 hours before applying power to allow any condensation resulting from low shipping/storage temperatures to evaporate. Use in Combination with Legacy Devices The Wireless Receiver is suitable for use only with the T0A00, T0A0, T0B00 Wireless Wall Modules and the RT00A00 Wireless Handheld Remote Control. It cannot communicate with (but is likewise unaffected by) legacy devices (e.g. the T0A00, T0A0, T0B00, or the RT00A00). Set-Up Because of interference from other devices and the building structure, it is not possible to exactly define the wireless transmission range. For further details, see section "Installation of Wireless Systems" on page. Wire the 's communications network using level IV AWG or plenum-rated level IV AWG non-shielded, twisted pair, solid conductor wire. INSTALLATION See Fig. for outside dimensions and Fig. for sub-base mounting dimensions. The can be mounted in any orientation desired on a panel, wall, or onto a standard wall outlet box (see Fig. ). Power Input power provided must be 4 Vac (±0%), 0 or 0 Hz. The power consumption of the (including the connected active antenna) is VA. CAUTION Avoid electrical shock or equipment damage. Turn power OFF prior to connecting to or removing connections from any terminals. Use the heaviest gauge wire available, up to 4 AWG (. mm ), with a minimum of AWG (.0 mm ) for all power wiring. U.S. Registered Trademark Copyright 00 Honeywell Inc. All Rights Reserved

2 WIRELESS RECEIVER 4 Wiring Details Fig. illustrates the terminal assignments of the. Refer to job drawings for specific wiring diagrams. Connections to the are made at an internal terminal block accessible beneath the front cover. No tools are required to remove the front cover.. Simply pull away the cover from the sub-base as shown in Fig.. Fig.., outside dimensions (in mm) 0 0 Use a minimum wire size of 0 AWG (0. mm ) for all input / output connections. The maximum length of all input / output cables is 0 m. Wire to the terminal blocks as follows:. Strip mm insulation from the conductor.. Insert the wire in the required terminal location and tighten the screw to complete the termination. 4. Ensure that the wire entering the terminal block does not extend above the numbered face of the terminal block to avoid contact between the wires and the printed circuit board on the underside of the front cover (see Fig. ). Fig.. Sub-base mounting dimensions (in mm) ORANGE BROWN TERMINATION MODULE (04B) Fig. 4. Termination module connection (daisy-chain network configuration) VAC 0/40 VAC 4 VAC COM LONWORKS NETWORK IN LONWORKS NETWORK OUT External Antenna VAC 4 VAC 4 VAC 4 VAC EXTERNAL BUS- EXTERNAL BUS+ Fig.. terminal assignments Fig.. Mounting on wall outlet box

3 WIRELESS RECEIVER EXTERNAL Each is delivered together with a corresponding External Antenna, to which it must be connected before it can receive signals from the devices. Install the External Antenna only outside of metal housings (e.g. control cabinets). Fig.. Terminal cover removal 4 0 Fig.. External Antenna, dimensions (mm) Install the External Antenna at a suitable location near (i.e. within 0 m) of the. External Antenna Fig.. Terminal box connections Environmental Ratings Operating Temperature (0 0 C). Shipping/Storage Temperature (-0 0 C). Relative Humidity % non-condensing Receiver Class The External Antenna (Receiver Class ) is an active electronic element. It broadcasts no electromagnetic energy. Communication between the External Antenna and the is via bus (see also Fig. ). Housing IP0 max. 0 m Fig.. Max. distance The External Antenna may be connected to only a single. See also section " External Antenna Installation and Wiring" on page. Installation of Wireless Systems Due to the use of wireless technology for sending signals from transmitters i.e. room units to evaluation units (receivers) and the discontinuation of the use of electrical cable connections, there are some basic guidelines that must be followed during planning and installation. This information is intended to help both the planner with configuring the radio path and the system integrator/engineer or service technician with installation and troubleshooting.

4 WIRELESS RECEIVER Basics for Radio Signals in Buildings Radio signals are electromagnetic waves and as such diminish in strength on their way from the transmitter to the receiver, even when unobstructed. This drop in signal strength is inversely proportional to the square of the distance between the transmitter and the receiver. Table. Evaluating installation environment pathway unobstructed direct line of sight gypsum wall/wood brick wall/gas concrete reinforced concrete walls/ceilings typical range 0 m in passages, corridors, up to 00 m in halls m through max. 4 walls m through max. walls 0 m through max. wall/ceiling SIGNAL STRENGTH NOTE: Storage areas and elevator shafts should be regarded as obstructions. X DISTANCE SHEET METAL Fig. 0. Attenuation of signal strength with distance Physical Obstructions Beside this natural (distance-dependent) drop in signal strength, the presence of physical obstructions (e.g. walls, metallic objects, reinforcements in walls, metallized foils of thermal insulations or metallized heat-absorbent glass) located between the transmitter and the receiver can further weaken signal strength. This is referred to as "damping attenuation." It is true that radio waves can penetrate walls to an extent, but the resultant drop in signal strength is greater than with unobstructed propagation in the free field. Here are some examples of the blocking effect of different types of walls: Fig.. Obstruction of signal Likewise, avoid mounting the antenna and transmitter such that the radio waves travel along walls (see Fig. ). Table. Blocking effect of different wall materials material penetration wood, gypsum, uncoated glass without metal % brick, pressboard...% reinforced concrete with iron reinforcement 0...0% metal, aluminum pasting 0...0% In actual practice, this means that the building material used in a building is of paramount importance for the evaluation of the transmitting range. For an evaluation of the environment, some standard values are listed: X Fig.. Attenuation of signal strength at walls 4

5 WIRELESS RECEIVER Distance to Other Interference Sources A distance between the room units and other (thirdparty) transmitters (e.g. GSM / DECT / wireless LAN) of at least m should be maintained. RD-PARTY TRANSMITTER X MIN. m XRD-PARTY TRANSMITTER Fig.. Distance to interference sources Further, a minimum distance of cm should be maintained between different components (i.e. External Antennas, Wall modules, and Handhelds; it is, of course, no problem if a External Antenna and a Wireless Receiver are closer together). Mounting Of Receiving Antenna Ideally, an external receiving antenna should be mounted at a central location in the room. If possible, the antenna should have a distance of min. 0. m (min. λ/4, example: at MHz cm) to the wall and 0. m to the ceiling. CEILING Troubleshooting Table. Possible causes of trouble and measures error possible cause measure Ext. Antenna never receiving signal. Ext. Antenna sometimes not receiving signal. Receiver displays invalid values on LONWORKS interface. room unit not transmitting. Distance between room unit and Ext. Antenna beyond limit. Improper connection of Ext. Antenna. room unit not taught-in. Wrong room unit taught-in. room unit removed. Mounting place of the room unit has been changed. Change of ambient conditions (metal cabinets, door, equipment, people, jamming). Distance between room unit and Ext. Antenna at limit. room units have been taught in and, afterwards, Receiver has been recommissioned. Check room unit as described above. Decrease distance. Check routing of cable between Ext. Antenna and Receiver. Renewed teaching-in of room unit to Receiver. Renewed teaching-in of room unit to Receiver. Renewed teaching-in of room unit to Receiver. Shift room unit or Ext. Antenna. Ensure min. distance to interference source; remove obstructions. Shift room unit or Ext. Antenna. Decrease distance. Force updating by operating adjustment wheel of every taughtin Wall Module or pushing setpoint key of every taught-in Handheld. MIN. 0. m Fig. 4. Positioning antenna in ceiling area

6 WIRELESS RECEIVER External Antenna Installation and Wiring 4 External Antenna 0 /0 / JE-LiYCY xx0. mm² or JE-Y(St)Y xx0.mm² or JE-Y(St)Y x0.mm² Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce, Switzerland by its Authorized Representative: Honeywell GmbH Böblinger Strasse 0 Schönaich, Germany Tel.: (++4) (0) 0 0 Fax: (++4) (0) Subject to change without notice. Printed in Germany This document is definitive for the enclosed product and replaces all previous publications. Honeywell Inc. hereby declares that this device complies with the basic requirements and other relevant regulations of guideline //EC. The declaration of conformity of the product can be requested from the manufacturer. Note to non-e.u. countries: This product may only be used if operation in the MHz frequency band is permissible.

STC65 RS485 Modbus. EnOcean Receiver/Transmitter with RS485 Modbus Interface. Data Sheet. Application. Security Advice Caution.

STC65 RS485 Modbus. EnOcean Receiver/Transmitter with RS485 Modbus Interface. Data Sheet. Application. Security Advice Caution. STC65 RS485 Modbus EnOcean Receiver/Transmitter with RS485 Modbus Interface Data Sheet Subject to technical alteration Issue date: 27.06.2014 Application Bidirectional gateway for EnOcean-based sensors

More information

Excel 800 / Excel Web II CABLE SPECIFICATIONS

Excel 800 / Excel Web II CABLE SPECIFICATIONS HONEYWELL EXCEL 5000 OPEN SYSTEM Excel 800 / Excel Web II CABLE SPECIFICATIONS PRODUCT INFORMATION U.S. Registered Trademark Copyright 2014 Honeywell Inc. All Rights Reserved EN0B-0689GE51 R0114 Excel

More information

SR65 TF Series Wireless Cable Temperature Sensors

SR65 TF Series Wireless Cable Temperature Sensors Applications SR65 TF Series Wireless Cable Temperature Sensors Wireless and battery-less air-duct sensors for temperature control. Features Integrated 868.3 MHz transmitter (transmissions conform to the

More information

SR04 rh Series Wireless Room Temperature/Humidity Sensors

SR04 rh Series Wireless Room Temperature/Humidity Sensors Applications Series Wireless Room Temperature/Humidity Sensors Wireless and battery-less 868MHz room sensors for temperature, humidity and ventilation control. Features Integrated 868.3 MHz transmitter

More information

thanos SR Multifunction Room Operating Unit Data Sheet Application Functions

thanos SR Multifunction Room Operating Unit Data Sheet Application Functions thanos SR Multifunction Room Operating Unit Data Sheet Subject to technical alteration Issue date: 05.06.2014 Application The touch room operating panel thanos is designed for temperature and humidity

More information

ERM-DA. Installation Guide

ERM-DA. Installation Guide ERM-DA Installation Guide ERM-DA Product Overview Echoflex s ERM-DA is an active circuit transmitter that provides a low cost method of using a live electrical circuit as a switch. When the circuit is

More information

Echo Installer Guide. 90th A N NIV ERS A RY

Echo Installer Guide. 90th A N NIV ERS A RY 1919-2009 90th A N NIV ERS A RY MANUFACTURING IN THE UK FOR 90 YEARS 1. Introduction The MK echo range of products are different from all other products in MK s Wiring Devices portfolio in so far as the

More information

Excel 15 S7760A COMMAND DISPLAY

Excel 15 S7760A COMMAND DISPLAY Excel 15 S7760A MAND DISPLAY INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The S7760A Command can be used to monitor and control H equipment, lighting, and other miscellaneous loads in a distributed network.

More information

Battery-Free Wireless Pushbutton Useful Tips for Reliable Range Planning

Battery-Free Wireless Pushbutton Useful Tips for Reliable Range Planning Battery-Free Wireless Pushbutton Useful Tips for Reliable Range Planning,, 2010-11-12,, leipzig@schlegel.biz, www.schlegel.biz 1. INTRODUCTION Compared to wireline systems, wireless solutions enable convenient

More information

radio controlled, battery-powered radiator valve actuator SAB05 with M30x1,5 connection

radio controlled, battery-powered radiator valve actuator SAB05 with M30x1,5 connection SAB05 868 MHz EasySens wireless radiator valve actuator for room temperature control Data Sheet Subject to technical alteration Issue date: 18.07.2014 Application Small, radio controlled, battery-powered

More information

Excel 10 W7761A Remote Input/Output Device

Excel 10 W7761A Remote Input/Output Device Excel 0 W776A Remote Input/Output Device INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The W776A Remote Input/Output (RIO) Device is a Free Topology Transceiver (FTT) LonMark compliant device in the Excel

More information

Technical data lumina MS4/RC

Technical data lumina MS4/RC Technical data 1. Product description The LON multisensor lumina MS4/RC is a combination of occupancy sensor, two light sensor, external temperature sensors, infrared remote control receiver and EnOcean

More information

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual Active Transmitter Combiner 8:1 AC 3200-II Instruction manual Contents Contents Important safety instructions... 2 The AC 3200-II active transmitter combiner 8:1... 4 Delivery includes... 4 Connection

More information

M7061 ROTARY VALVE ACTUATORS

M7061 ROTARY VALVE ACTUATORS M0 ROTARY VALVE ACTUATORS PRODUCT DATA FEATURES Protected against overload and blocking Maintenance-free electrical actuator for rotary valves Clear position indicator Direct mounting on rotary valves

More information

Wireless and battery-less room units with EnOcean interface

Wireless and battery-less room units with EnOcean interface s 1 663 QAX95.4 QAX96.4 QAX97.4 QAX98.4 Wireless and battery-less room units with EnOcean interface Usable with devices from the following ranges: RXC (together with gateway EnOcean/LONWORKS, RXZ95.1/LON)

More information

Excel 10 W7751B,D,F VAV Controllers

Excel 10 W7751B,D,F VAV Controllers Excel 0 W77B,D,F VAV Controllers INSTALLATION INSTRUCTIONS BEFORE INSTALLATION The Excel 0 VAV Controller is a Free Topology Transceiver (FTT) LonMark compliant device that is available in three versions:

More information

Allure ECW-Sensor Series

Allure ECW-Sensor Series Datasheet Room Temperature Sensors Overview The Allure ECW-Sensor series are wireless and battery-less room temperature sensors specifically designed to communicate with Distech Controls Open-to- Wireless

More information

EnOcean Wireless Systems RANGE PLANNING GUIDE

EnOcean Wireless Systems RANGE PLANNING GUIDE Wireless systems provide much simpler installation as well as the flexibility to relocate or add to a system, compared to installing wired systems. The easy recommendations in this planning guide are provided

More information

User Manual EnOcean V 0.1

User Manual EnOcean V 0.1 & User Manual EnOcean V 0.1 Last update: July 2012 All software-related descriptions refer to the software V1279. We recommend to update older versions of the system. Small deviations in the description

More information

Measuring current transformers of the W, W series

Measuring current transformers of the W, W series Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000

More information

EnOcean Wireless Systems RANGE PLANNING GUIDE

EnOcean Wireless Systems RANGE PLANNING GUIDE Wireless systems provide much simpler installation as well as the flexibility to relocate or add to a system, compared to installing wired systems. The easy recommendations in this planning guide are provided

More information

Range Planning Guide for Systmes usind EnOcean Radio Standard

Range Planning Guide for Systmes usind EnOcean Radio Standard Range Planning Guide for Systmes usind EnOcean Radio Standard Wireless systems provide much simpler installation as well as the flexibility to relocate or add to a system, compared to wired systems. The

More information

Current Loop Interface Module M 2025D

Current Loop Interface Module M 2025D CONTROLS Current Loop Interface Module M 2025D Current-to-Voltage Analog Converter used with the M 2001 Series Digital Tapchanger Control and M-2948 Tap Position Sensors to provide positive tap position

More information

Planning Guide For Wireless Sensors

Planning Guide For Wireless Sensors Planning Guide For Wireless Sensors C o n t e n t s Contents 1 Section 1: Introduction 3 Who should read this guide? 3 Basic sensor network 4 Compatibility with other systems 4 Section 2: Principles of

More information

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02 Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02 Installation Guide WirelessSet485-IEN091511 98-0009411 Version 1.1 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes

More information

basicdim Wireless Casambi Ready

basicdim Wireless Casambi Ready Passive Module wireless module Product description Wireless controllable with a Android / ios smart device No need for an external gateway device Forms automatically a wireless communication network with

More information

Air damper actuators

Air damper actuators 4 656 OpenAir TM Air damper actuators GBB...2 Electronic motor-driven linear actuators for three-position and modulating control AC 24 V / AC 230 V Nominal force 550 N Travel 75 mm, mechanical adjustable

More information

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description Voltage transducer for AC voltages TERFACE Data sheet 006_en_0 PHOENIX CONTACT 00-0- Description The MCR voltage transducer measures AC voltages in several signal ranges from 0... ±4 V AC to 0... ±30 V

More information

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions DT1100 E xx xx (PS) Galvanic Isolators Operating Instructions Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized

More information

Page 1 of Release 2.2. LON Transponder Reader. Technical Reports

Page 1 of Release 2.2. LON Transponder Reader. Technical Reports Page 1 of 22 2000-01-11 Release 2.2 LON Transponder Reader Technical Reports Release 2.1 Page 2 of 22 1 SYSTEM DESCRIPTION 3 2 IMPORTANT NOTES: 4 3 HARDWARE 5 3.1 CONSTRUCTION 5 3.2 STANDARD HOUSING 7

More information

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions Isolators, Isolator / Power Supplies Operating Instructions EN Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized

More information

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O DATASHEET NI REM-11120 Temperature Input Module for Remote I/O 4 thermocouple channels with input range of ±100 mv 1 voltage input channel with range of ±5V 24-bit resolution Optional external CJC or additional

More information

SER8300 Series Terminal Equipment Controller with Optional PIR sensor Installation Guide

SER8300 Series Terminal Equipment Controller with Optional PIR sensor Installation Guide Room Controllers Terminal Equipment Controller with Optional PIR sensor Installation Guide Commercial and Hotel/Lodging HVAC Fan Coil Applications 1 CONTENTS Installation 2 Location 2 Installation 2 Terminal,

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Product and Applications Description

Product and Applications Description Product and pplications Description Diagram The transmitter 230V wave UP 110 (Diagram ) is a flushmounted device with radio communication for the wireless operation of room functions. It is possible to

More information

Gateway EnOcean/LonWorks

Gateway EnOcean/LonWorks s 1 661 1661P01, 1661P02 DESIGO RXC Gateway EnOcean/LonWorks For use with: DESIGO RXC Devices / systems with LONWORKS communication RXZ95.1/LON Wireless receiver with LONWORKS interface FTT10A Evaluation

More information

C-Bus 8 Channel Low Voltage Relay

C-Bus 8 Channel Low Voltage Relay SLC5108RELVP Instruction Bulletin Retain for future use. 63249-420-325A1 Instruction Bulletin 07/2009 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment to

More information

FTT-10A Free Topology Twisted Pair Transceiver Model 50051

FTT-10A Free Topology Twisted Pair Transceiver Model 50051 FTT-10A Free Topology Twisted Pair Transceiver Model 50051 Description The FTT-10A Free Topology Twisted Pair Transceiver provides a simple, cost-effective method of adding a LONWORKS transceiver to any

More information

Astra-R Kit Wireless Alarm System Operation Manual

Astra-R Kit Wireless Alarm System Operation Manual Astra-R Kit Wireless Alarm System Operation Manual This operation manual describes principles of functioning, proper use, maintenance and service for the wireless alarm system Astra- R Kit (Figure 1).

More information

TOP VIEW. 6.75" (171.5mm) Network ID Selector. Input Voltage Selection Jumper 7.285" (185mm) Battery Positive Terminal SIDE VIEW. 6.12" (155.

TOP VIEW. 6.75 (171.5mm) Network ID Selector. Input Voltage Selection Jumper 7.285 (185mm) Battery Positive Terminal SIDE VIEW. 6.12 (155. Installation and Operation Instructions RR2552 Spread Spectrum Repeater TOP VIEW 6.75" (171.5mm) Network ID Selector Ø0.190 (4 PLCS.) Data Link LED 3.5" 4.72" (88.9mm) (119.89mm) Active LED Battery Positive

More information

NV-WA40W. Installation and User Guide

NV-WA40W. Installation and User Guide NV-WA40W Installation and User Guide Introduction The NV-WA40W-AMP is a versatile 40-watt in wall zone amplifier perfectly suited to a variety of tasks. Its design allows two line level sources to be permanently

More information

Precipition Sensor with analogue Intensity Output ,

Precipition Sensor with analogue Intensity Output , THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021335/11/09 Precipition Sensor with analogue Intensity Output 5.4103.20.041, 5.4103.20.741 ADOLF THIES

More information

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION Installation and Operation Manual MSI Multi-Sensor Interface Hub Interface Module for all Sensors Network and Wireless CAUTION This equipment complies with the limits for a Class B digital device, pursuant

More information

Wind Transmitter - with frequency output xx.xxx

Wind Transmitter - with frequency output xx.xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021531/11/09 Wind Transmitter - with frequency output 4.3303.xx.xxx ADOLF THIES GmbH & Co. KG Hauptstraße

More information

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

ECB-103 BACnet B-ASC 10-Point Programmable Controllers D a t a s h e e t BACnet B-ASC 10-Point Programmable Controllers Overview The is a microprocessor-based programmable controller designed to control terminal units such as fan coil unit, heat pump unit,

More information

Wireless multizone receiver RDE-MZ6

Wireless multizone receiver RDE-MZ6 s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output

More information

Precipitation Monitor ,

Precipitation Monitor , THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021197/11/09 Precipitation Monitor 5.4103.10.000, 5.4103.10.700 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Heavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e

Heavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e Sendix H00 (shaft) The Sendix encoder H00 is an extremely rugged available in 3 versions: encoder with or without speed switch and double encoder. Thanks to the special HD-Safety-Lock construction it is

More information

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values).

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values). Operating Instructions Communication Interfaces 1 Interfaces and Options 1.1 Optical (infrared) interface For communication with the optical interface an optocoupler and the Device Monitor software are

More information

Wind Transmitter First Class Advanced Classified according to IEC ( )

Wind Transmitter First Class Advanced Classified according to IEC ( ) THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021519/01/09 Wind Transmitter First Class Advanced Classified according to IEC 61400-12-1 (2005-12)

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires. FEATURES - Extends wiring distance of FTT-10 LonWorks Networks. - Up to 5 repeaters can be daisy chained together to create a multi-segment repeater of up to 10 channels. - Low cost alternative to routers

More information

Universal 1-channel switching receiver EnOcean Easyfit RCM 250

Universal 1-channel switching receiver EnOcean Easyfit RCM 250 Universal 1-channel switching receiver EnOcean Easyfit RCM 250 User Manual V1.14 May 2007 Revision History The following major modifications and improvements have been made to the initial version of the

More information

Instruction manual for STA 1 sectional door operator

Instruction manual for STA 1 sectional door operator Instruction manual for STA 1 sectional door operator Sectional door operator STA 1 / Rev. 0.3 1 GB 1. Contents 3. General safety instructions 1. Contents 2 2. Key to symbols 2 3. General safety instructions

More information

Installation guide 971 SmartRadar LTi

Installation guide 971 SmartRadar LTi Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl

More information

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL MD-45 AC MD-45 LV/HV INSTALLATI MANUAL 6157-2213 Westermo Teleindustri A 2003 REV.A Galvanic Isolation Transient Protection alanced Transmission CE Approved Converter RS-232 RS-422/485 www.westermo.us

More information

Table of Contents. Mounting Diagram.. Wiring Information.. Setting the STR 1000 as a Repeater or a Transmitter. STR 1000 Frequently Asked Questions..

Table of Contents. Mounting Diagram.. Wiring Information.. Setting the STR 1000 as a Repeater or a Transmitter. STR 1000 Frequently Asked Questions.. STR 1000 Series Repeater Installation Manual (V 3.0) Table of Contents MOUNTING Mounting Diagram.. Page 2 WIRING INFORMATION Wiring Information.. Page 3 Setting the STR 1000 as a Repeater or a Transmitter.

More information

Wireless 900 MHz Receiver

Wireless 900 MHz Receiver Overview and Identification The 900 MHz unit receives a repeated or re-transmitted RF signal from one or more wireless temperature or humidity transmitters. The signal from the transmitter (418 MHz) is

More information

Wind Transmitter First Class

Wind Transmitter First Class THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021310/07/06 Wind Transmitter First Class 4.3350.00.000 4.3350.10.000 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Planning Guidelines. Lightcloud. Best Practices for Installing Lightcloud

Planning Guidelines. Lightcloud. Best Practices for Installing Lightcloud Best Practices for Installing Lightcloud Planning Guidelines Lightcloud Network Wireless Networking Considerations Wireless Mesh Network Placement of Devices Powering Devices Placing the Gateway Installation

More information

1 Safety instructions. 2 Device components. 3 Function. Radio Management Repeater. Operationsmanual

1 Safety instructions. 2 Device components. 3 Function. Radio Management Repeater. Operationsmanual Art.-No.: 100 FR Operationsmanual 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to the

More information

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany 522 WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany WAGO Products: WAGO-I/O-SYSTEM with ETHERNET Controllers, DALI and EnOcean Components Wireless Technologie System Overview 524

More information

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type) Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type) ECY-SD Proximity Sensor with Separate Amplifier Unit for Detection of Non-ferrous Metals with Simple Adjustment Detects aluminum,

More information

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building

More information

Wind Transmitter compact xx

Wind Transmitter compact xx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021075/08/11 Wind Transmitter compact 4.3519.xx.140... 961 ADOLF THIES GmbH & Co. KG Hauptstraße 76

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Model: RMR183 & RMR183U User Manual

Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Model: RMR183 & RMR183U User Manual Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Model: RMR183 & RMR183U User Manual RMR183-e Cover R2 OP 1 Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

HLV Instruction & Operations Manual. Content

HLV Instruction & Operations Manual. Content HLV-800-3 Instruction & Operations Manual Content 1 Chapter page 1. Certificate of conformity 3 2. Introduction 4 3. Safety instructions 5 4. Electrical connections 6 5. Warranty 7 6. Front panel operation

More information

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing

More information

EC 45 flat with integrated electronics Document ID: en Operating Manual

EC 45 flat with integrated electronics Document ID: en Operating Manual EC 45 flat with integrated electronics Document ID: 919801en Operating Manual Edition June 2017 The EC 45 flat with integrated electronics is a brushless, speed-controlled 1-quadrant drive. It is available

More information

FSW-1650 FSW User Manual. 16/24-Port 10/100 Rackmount Switch

FSW-1650 FSW User Manual. 16/24-Port 10/100 Rackmount Switch FSW-1650 FSW-2450 User Manual 16/24-Port 10/100 Rackmount Switch V1.0.0.0810 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. LevelOne is a registered trademark of Digital Data

More information

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4..

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4.. Installation instructions Angle position transmitter Type RT-2 Marine bridge instrumentation DEIF A/S Analogue output for direct connection of one or more indicators Measuring output: DC current signal

More information

Gateway EnOcean/LonWorks

Gateway EnOcean/LonWorks s 1 661 1661P01, 1661P02 DESIGO RXC Gateway EnOcean/LonWorks For use with: DESIGO RXC Devices / systems with LONWORKS communication RXZ95.1/LON Wireless receiver with LONWORKS interface FTT10A Evaluation

More information

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control s OpenAir Air damper actuators GDB..1E Electronic motor driven actuators for open-close, three-position and modulating control Nominal torque 5 Nm Operating voltage AC 24 V ~ / DC 24 48 V or AC 100 240

More information

2-/4-Channel flush-mounted transmitter FS20 S4U

2-/4-Channel flush-mounted transmitter FS20 S4U OPERATING INSTRUCTIONS Version 12/06 2-/4-Channel flush-mounted transmitter FS20 S4U Item no. 62 02 95 Introduction Dear customer, Thank you for purchasing this product. This product meets the requirements

More information

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description RAD-IN/OUT-D Digital extension modules for the bidirectional wireless system INTERFACE Data sheet 102122_en_0 PHOENIX CONTACT 2010-02-2 1 Description The RAD-ISM-...-SET-BD-BUS-ANT bidirectional wireless

More information

High power radio transmission module MR03 type

High power radio transmission module MR03 type High power radio transmission module MR03 type User s manual CONTENTS 1. APPLICATION...3 2. MR03 MODULE SET...4 3. INSTALLATION...4 3.1 Module assembly...4 3.2 Connection diagrams...5 3.3 Connection way

More information

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at Connevans.info Solutions to improve the quality of life Offering you choice Helping you choose This product may be purchased from Connevans Limited secure online store at www.deafequipment.co.uk DeafEquipment.co.uk

More information

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons. enet Server Order No. : 5301 00 Power adapter enet Server 12 V DC Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious

More information

Electromotoric actuators for stroke valves

Electromotoric actuators for stroke valves s ACVATIX Electromotoric actuators for stroke valves SAS.. Electromotoric actuators with 5.5 mm stroke and 400 N positioning force SAS31.. Operating voltage AC 230 V, 3-position control signal Operating

More information

Operating Instructions. EnOcean radio wall transmitter

Operating Instructions. EnOcean radio wall transmitter Operating Instructions 1. Safety instructions Electrical devices may only be installed and fitted by electrically skilled persons. Non-compliance with the instructions could cause damage to the device,

More information

EY-EM 527: Remote I/O module, ecolink527

EY-EM 527: Remote I/O module, ecolink527 Product data sheet 94.078 EY-EM 527: Remote I/O module, ecolink527 How energy efficiency is improved Regulation, control, monitoring and optimisation of operational systems, e.g. room automation or HVAC

More information

1 Safety instructions. 2 Device components. 3 Function. Radio bus system. Radio socket-outlet adapter for switching Order No. :

1 Safety instructions. 2 Device components. 3 Function. Radio bus system. Radio socket-outlet adapter for switching Order No. : Order No. : 0401.. Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible.

More information

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601 Operating Instructions for Pressure Sensor with Ceramic Sensor Element Model: SEN-9601 We don t accept warranty and liability claims neither upon this publication nor in case of improper treatment of the

More information

Wind Transmitter - compact

Wind Transmitter - compact THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021194/02/07 Wind Transmitter - compact 4.3518.03.000 4.3519.03.000 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

IntesisBox ME-AC-ENO-1 / 1C v.1.0.9

IntesisBox ME-AC-ENO-1 / 1C v.1.0.9 IntesisBox ME-AC-ENO-1 / 1C v109 EnOcean Interface for Mitsubishi Electric air conditioners ME-AC-ENO-1 and ME-AC-ENO-1C devices allow a complete and natural integration of Mitsubishi Electric air conditioners

More information

MINI-PS AC/2X15DC/1

MINI-PS AC/2X15DC/1 MII-PS-100-240AC/2X15DC/1 Power supply unit ITERFACE Data sheet 100299_en_04 1 Description PHOEIX COTACT - 2010-10-20 Features MII POWER is the extremely slim power supply unit with constructional widths

More information

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions Order No. : 1185.. Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible.

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver C 5W 35-6mA flexc SC advanced series Product description Can be either used build-in or independent with clip-on strain-relief (see accessory) Constant current Adjustable output current between

More information

Current Loop Interface Module M-2025C

Current Loop Interface Module M-2025C CONTROLS Interface Module M-2025C Current-to-Voltage Analog Converter used with the M-2001 Series Digital Tapchanger Control and M-2948/M-2949 Tap Position Sensors to provide positive tap position knowledge

More information

Frequently Asked Questions

Frequently Asked Questions Frequently Asked Questions This document provides a non-exhaustive collection of some of the questions frequently asked by our customers. What is your system s wireless range? 1 What are the risks of interference

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Transducer transmitter BILT 4 II 2(1) G. Technical Manual GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical

More information

TWS One Vocal UHF wireless system. user manual

TWS One Vocal UHF wireless system. user manual TWS One Vocal UHF wireless system user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

H LONTalk Integration Node For Use With H704 and H663 Branch Current Monitors (BCM) H NOTICE DANGER INSTALLATION GUIDE DIMENSIONS

H LONTalk Integration Node For Use With H704 and H663 Branch Current Monitors (BCM) H NOTICE DANGER INSTALLATION GUIDE DIMENSIONS POWER MONITORING INSTALLATION GUIDE H8920-4 H8920-4 LONTalk Integration Node For Use With H704 and H663 Branch Current Monitors (BCM) Installer s Specifications LonWorks Network Network Variable Type Input

More information

Technical Description. Wireless Automation Input/Output Module WDIO100

Technical Description. Wireless Automation Input/Output Module WDIO100 Technical Description Wireless Automation Input/Output Module Please note the following Target group This description is intended for the use of trained specialists in electrical installation and control

More information

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operational Instructions for ROBA -switch Type 017._00.2 OBA -switch Type 017._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EC Low Voltage Directive 2014/35/ EC and the EMC Directive

More information

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Configured air damper actuators 6FU11xx-xDxxx-xxxx s OpenAir Configured air damper actuators 6FU11xx-xDxxx-xxxx Electronic motor driven actuators for open-close, three-position and modulating control Nominal torque 5 Nm Operating voltage AC 24 V ~ / DC

More information