1 Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement
2 MODEL 31 Function Description of Product The 31 Smart Pressure Transmitter is a micro processor-based high performance transmitter, which has flexible pressure calibration and output, automatic compensation of ambient temperature and process variable, configuration of various parameters, communication with HART protocol. The application is very various, as measuring liquid, gas or steam flow as well as pressure and liquid level by application method. All data of sensor is to be input, modified and storedin EEPROM.» Flexible Sensor Input : DP, GP, AP, HP» Various Output : ~0mA, Digital Signals»Setting Various Parameters : Zero/Span, Trim, Unit, Fail-mode, etc.»self Diagnostic Function : Sensor, Memory A/D Converter, Power, etc» Digital Communication with HART protocol» Explosion-proof Approval & Intrinsic Safety Approval : ATE, FM, FMCanada, GOST, KOSHA, KTL, etc.» Marine Certificate: ABS, LR, BR, DNV Functional Block Diagram MCU Part Sensor Part A/D Conversion EEPROM sensor High Pressure User-Selectable Input DP/GP/HP/ AP Measuring Range Microprocessor Input Sensor Value Engineering Units Re-range (Zero / Span) Sensor Trimming Zero Point Adjustment DA Trimming Damping / Filtering Transfer function LCD Engineering Mode Diagnostics Self Compensation Communications LCD Display Configuration Data -0mA DAC HART HART Protocol with Host
3 Features» Superior Performance High Reference Accuracy : ±0.075% of Calibrated Span (The option : ±0.0% of Calibrated Span) for range ±0.5% of Span for 0.1URL Span URL ±[0. + (0.00 x (URL/span))]% of Span for 0.05URL Span < 0.1URL for range 3 ±0.075% of Span for 0.1URL Span URL ±[ (0.005 x (URL/span))]% of Span for 0.0URL Span < 0.1URL for ranges to 0 ±0.075% of Span for 0.1URL Span URL ±[0.05+(0.005 x (URL/span))]% of Span for 0.01URL Span 0.1URL Long-Term Stability (0.15% URL for 3year) High Rangeability (100 : 1)(for the range -0)» Flexibility Data Configuration with HART Configurator Zero Point Adjustment» Reliability Continuous Self-Diagnostic Function Automatic Ambient Temperature Compensation Fail-mode Process Function EEPROM Write Protection CE EMC Conformity Standards (EN5001-, EN500-) Transmitter Description 31 Pressure transmitter can be easily configured from any host that support the HART protocol.» Basic Setup Operational Parameters. ~0mA Points (Zero/Span) Engineering Units Damping Time : 0.5 ~ 60 sec Tag : alphanumeric characters Descriptor : 16 characters Message : 3 characters. Date : day/month/year» Calibration and Trimming Lower/Upper Range (zero/span) Sensor Zero Trimming Zero Point Adjustment DAC Output Trimming Transfer Function Self-Compensation» Self-Diagnosis and Others CPU & Analog Module Fault Detection Communication Error Fail-mode Handling LCD Indication Temperature Measurement of Sensor Module Function» Range and Sensor Limits Refer to Table 1.» Zero and Span Adjustment Limits Zero and span values can be set anywhere within the range limits stated in Table 1.(Page 9) Span must be greater than or equal to the minimum span stated in Table 1.(Page 9)» Output (Analog Current and Digital Data) LCD Display & ENG Mode Two wire ~0mA user-configurable for linear or square root output, digital process value superimposed on ~0mA signal, available to any host that conforms to the HART protocol» Power Supply & Load Requirement External power supply required. * 50 ohm load Vdc * up to a 550 ohm load -- Vdc Max. Loop Resistance = ( E - 1 ) / 0.0 (E = Power Supply Voltage) Voltage Range : 1 to 5 Vdc Voltage Rating : Vdc ±30% Loop Load 0 ~ 1500 ohm -- Operation 50 ~ 550 ohm -- HART Communications» EMC Conformity Standards EMI (Emission) EN5001-:1993 EMS (Immunity) EN500-:1995» Failure Mode Fail High : Current 1.1 ma Fail Low : Current 3.7 ma» Storage Temperature -0 to 5 (without condensing)» Process Temperature Limits (Range codes and approval codes may effect limits) -0 to 10 ( -10 to )
4 Function» Isolation Input/output isolated to 500Vrms (707 Vdc)» Working Pressure Limits (silicone oil) Model D & G 0 ~ MPa - # 3 ~ Model G 0 ~ 0.00 MPa - # 9 0 ~ MPa - # 0 Model H 0 ~ 31.0 MPa - # ~ 7 Model A 0 ~ 55 KPa - # 0 ~ 3000 KPa - # 5 0 ~ 550 KPa - # 6» Change main parameter by Button Change Unit Change Upper range value Change Lower range value Change the Damping Second Select the Decimal Place Zero Trim Zero Adjustment» Hydrostatic Test Pressure Model D 3000 psi (0.7 MPa) Model H 6750 psi (6.5 MPa) Model G 000 psi (13. MPa) - # 3 ~ psi (0 MPa) - # psi (0 MPa) - # 0 Model A psi (700 KPa) - # 50 psi (000 KPa) - # psi (7000 KPa) - # 6» Burst Pressure Model D, G, H 6.9 MPa G~9 50 MPa G0 0 MPa Model A 1050 KPa A5 000 KPa A KPa Moving within Menu : Zero Moving to below Menu : Span Moving Top Menu : Zero+Span» Button Manu Tree» 5 Digit LCD Express all pressure unit and flow unit. Use 5 digit. Select decimal place (0 to )» User define unit function
5 Physical Specifications» Wetted Materials Isolating Diaphragms, Monel, Tantalum, HAST-C Drain/Vent Valves, HAST-C Flanges and Adapters (ASTMCFM), HAST-C O-ring Viton, PTFE» Non-wetted materials Fill Fluid Silicone oil or Inert fill Bolts 30 SST Electronics Housing Aluminum or (Option) Flameproof and Waterproof (IP67) Cover O-ring Buna-N Paint Epoxy-Polyester or Polyuret Mounting Bracket 30SST with U-bolt (30SST) for -inch pipe Nameplate 30SST Exploded drawing of Model 31» Electrical connections 1/-1 NPT conduit with M Screw Terminals» Process Connections 1/-1 NPT on.16 inch (5.0 mm) centers on flanges for Standard 1/-1 NPT on Process Adapter (option) * Refer to drawing in the last page» Weight 3.9 kg ( Standard - excluding options ) 5.35kg (SST Housing- excluding options) 30 SST
6 Hazardous Location Certifications (option)» KOSHA Approvals K1 Code : * KOSHA: Korea Occupational Safety & Health Agency Flameproof for Class I, Zone 1 : Ex d ⅡC T6, IP67 Ambient Temperature : -0 to 60 C Max. Process Temperature : 0 C Power Supply : Max. 5 Vdc Output : to 0 ma + HART, Max. ma» ATE ApprovalsE1 Code : CE 03 II G Ex d IIC T6, T5 or T Operating Temperature: -00C Tamb +6 0 C T6 for process 50C ; T5 for process 100 C T 1300C APT3100 ATE Certification is according to the below standards : EN : 006 EN : 007» KTL Certification K Code : * Intrinsic Safety: Ex ia IIC T6 Ambient Temperature : -0 to 600C Ui=30Vdc, Ii=00mA, Pi=0.9W, Ci=7nF, Li=9μH» FM and FM Canada Approvals F1 Code : * FM: Factory Mutual explosion proof * FM Canada: Canadian requirements Explosion proof for Class I, Division 1 Groups A, B, C and D Dust-ignition proof for Class II/III, Division 1, Groups E, F and G Nonincendive for Class I, Division, Groups A, B, C & D; Class II, Division, Groups E, F & G; and Class III, Division 1, Enclosure: indoors and outdoors, NEMA Type Connection Diagram of Signal, Power, HHT for Transmitter HHT (HART Communicator) or PC Configurator may connected at any termination point in the signal loop. HART Communication requires a loop resistance between 50 and 550 Vdc Power Supply Voltage Range: 1 to 5 Vdc Voltage Rating: Vdc ± 30%
7 MODEL 31 MP Option Easy installation regarless fluid line conditions Advantage Conventionally, in the case where the pressure transmitter should be vertically installed irrespective of the orientation of the fluid inflow lines, modified flanges are required in addition to the basic flanges. As a result, the modified flanges must be additionally provided. Multi-planar pressure transmitter has been made in an effort to solve the problems occurring in the related art, and an object of this multi planar is to provide a pressure transmitter, capable of being vertically installed without separate adaptor or various types of brackets regardless of the position of each fluid inflow line. Dimension
8 MODEL 31F Description Wiring 31F is added the totalizing function in 31 transmitter. So it is available to check the flow rate and total flow.» Measuring & Express Flow rate and Total flow» Pulse output by accumulation of total flow» 31F measures the flow rate by using differential pressure so it is not compensated the temperature and static pressure In the case of connecting with Relay or Counter External Appearance Pulse Specification 31F is same shape with 31 but the terminal block is different.» Scaled Pulse : A Single pulse is output for a specified flow amount.» Pulse Width : 10ms, 50ms, 100ms selectable (Negative going pulse)» Duty Cycle : 9 Pulse/sec. Max.» Output Type : Open Collector, 30V, 500mA Max. 1: Pulse out + : Pulse out
9 GENERAL SPECIFICATIONS Pressure Sensor Range & URL Range Code DP/GP/HP/F Calibrated Span (KPa) Upper Range (URL) (KPa) ~ D.P -1.5 AP Lower Range (LRL) (KPa) G.P -1.5 H.P Calibrated Span (KPa) Range(KPa) ~ ~ ~ 50 0 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ inho@0c mmho@0c Range Code KPa Kg/cm bar psi Electrical Specifications Power Supply HART loop resistance 1 to 5 Vdc 50 ~ 550 ohm Output Signal Isolation inhg@0 C ~ 0 ma dc / HART 500 Vrms (707 Vdc) 3. Performance Specifications Reference Accuracy Ambient Temp. Effect Stability Static Pressure Effects ± 0.075% of Span (0.1URL Span URL) ±[ x(URL/Span)]% of Span (0.01URL Span<0.1URL) ±[0.019%URL+0.15% Span] / C ±0.15% URL for 36 Months ±0.1% of URL per 7MPa (Zero Error) ±0.% of Reading per 7Mpa(Span Error) Ambient Temperature -0 ~ +50C LCD Meter Ambient Temp Humidity Limits -30 ~ +00C 5% ~ 100% RH Process Temperature Limits Power Supply Effects -00C ~ +100C ±0.005% of Span per Volt Zero Shift up to 350Pa No Span Effect Mounting Position Effects. Physical Specifications Isolating Diaphragm Drain & Vent Valve Flange & Adapter O-ring Viton, PTFE Electronic Housing Bolts & Bolting Flange Aluminum (Option:) 30 SST Process Connection Size (Adapter Option) Electrical Connections Weight (excluding Option Items) Pipe Stanchion Type bracket Housing Class 1/ - 1 NPT 1/ 1 NPT 1/ 1 NPT with M 3.9 Kg (Standard) 5.35Kg(SST Housing) Angle or Flat type Waterproof (IP67),
10 ORDERING INFORMATION MODEL 31 Code Description -D Differential Pressure Transmitter (Static Pressure MPa / 000psi) -F Flow Transmitter (on the principle of Differential Pressure Use and only for Head) -G Gauge Pressure Transmitter -H Differential Pressure Transmitter for High Line Pressure (Static Pressure 31.0MPa / 500psi ) -A Absolute Pressure Transmitter DP/GP/HP Calibrated Span Min. to Max Ranges Mounting Flange/ Material Hazardous Location Certifications Electrical Connection Option APT3100-D APT3100-G APT3100-H Upper Range Limits Range APT3100-A ~ 1.5 KPa -1.5 KPa -1.5 KPa 1.5 KPa (6.0 inho) ~ 7.5 KPa -7.5 KPa -7.5 KPa 7.5 KPa (30 inho) ~ 37.3 KPa KPa KPa KPa 37.3 KPa (150 inho) 0~50 KPa ~ 16.5 KPa KPa -100KPa KPa 16.5 KPa (750 inho) 0~1500 KPa ~ 690 KPa -690 KPa -100KPa -690 KPa 690 KPa (100 psi) 0~500 KPa ~ 06 KPa -06 KPa -100KPa -06 KPa 06 KPa (300 psi) 6.95 ~ 695 KPa -695 KPa -100KPa 695 KPa (1000 psi) ~ 060 KPa -100KPa 060 KPa (3000 psi) ~ 1370 KPa -100KPa 1370 KPa (6000 psi) Body Vent Plug M11 M1 HAST - C M13 Monel M1 Tantalum M1 HAST - C HAST - C HAST - C M HAST - C HAST - C Monel M3 HAST - C HAST - C Tantalum Diaphragm K0 Maker Standard (Waterproof : IP67 ) K1 KOSHA Flameproof Approval K KTL Intrinsic Safety Approval E1 ATE(KEMA) Flameproof E ATE(KEMA) Intrinsic Safety FM & FM Canada Explosion proof F FM & FM Canada Intrinsic Safety F1 Fill Fluid Process Connection *AP Lower Range Limit 1 Silicone (DC00) Inert fill fluid (Halocarbon oil) S 1/ - 1 NPT (Standard) 0 1/ - 1 NPT Female (Adapter) 1 1/-1NPT Epoxy-Polyester Painted Aluminum G1/ Epoxy- Polyester Painted Aluminum(Adapter) LPE Lightening Protector (External) M1 LCD Indicator(5digit) MP Multi-Planar LPI Lightening Protector (Internal) K Oil Free Finish F1 Side Vent / Drain Top F Side Vent / Drain Bottom W Way Manifold (SST) : Remote type type WF Flange Type Flange Type Flange Type 3W 3 Way Manifold (SST) : Remote type type 3WF 5W 5 Way Manifold (SST) : Remote type type 6WF BA Stainless Steel Bracket (Angle type) with SST BF Stainless Steel Bracket (Flat type) with SST ST Stainless Steel Housing T Teflon O-Ring (Wetted Part)
11 Installation With Mounting Bracket Pipe Mounting Bracket Model Angle Type Standard Model MP Model Pipe Mounting Bracket Model Flat Type Standard Model MP Model
12 Dimensions of Transmitter (mm) Standard Model Intrinsically Safe Model
13 Smart Pressure Transmitter with Diaphragm Seal MODEL 31L
14 Smart Pressure Transmitter with Diaphragm Seal MODEL 31L Description of Product The 31L Smart Pressure Transmitter is a micro processor-based high performance transmitter, which has flexible pressure calibration and output, automatic compensation of ambient temperature and process variable, configuration of various parameters, communication with HART protocol. All Data of Sensor(Tag No., Type, Range) is to be input, modified and stored in EEPROM. Features Superior Performance High Reference Accuracy : ±0.075% of Calibrated Span (without seal) Long-Term Stability High Rangeability ( 0 : 1 ) Flexibility Data Configuration with HART Configurator Zero Point Adjustment Reliability Continuous Self-Diagnostic Function Automatic Ambient Temperature Compensation Fail-mode Process Function EEPROM Write Protection CE EMC Conformity Standards (EN5001-, EN500-) Function» Flexible Sensor input : Measuring hydrostatic pressure head and transmitting liquid level»various output: ~0mA(Analog),Digital Signals» Automatic Compensation of Ambient Temperature» Setting Various Parameters : Zero/Span, Fail-mode, Unit, Trim, etc.» Self Diagnostic Function : Sensor, A/D Converter, Memory, Power, etc» Digital Communication with HART protocol, Command.» Explosion-proof Approval & Intrinsic Safety Approval : KOSHA, KTL,CSA, FM & ATE Functional Block Diagram Sensor Part A/D Conversion EEPROM Sensor High Pressure Low Pressure Level Type of Sensor & Configure Tools Selection of Various Pressure - Using Capacitive Pressure Sensor - Screw type. Diaphragm Seal as to process connection method. - User can select measuring sensor for DP, GP. MCU Part Microcomputer o Input Sensor Value o Engineering Units o Rerangement o Filtering / Damping o Diagnostics o Self Compensation o Communications o LCD Display o Configuration Data o LinearizationTable o LinearizationTable o Trimming Constants o Range Value DAC ~0mA HART HART Protocol with Host Transmitter Output - Analog : ~ 0mA DC -Digital : HART Digital Data. Configure Tools - Hand-Held Terminal : portable use in job-site, convenient input, change, review, up-down loading - The Configurator Software Package can be loaded on PC for users convenience
15 General Specificatons 1. Diaphragm Sealed Sensor Range (Rangeability : 0 : 1) Class Low Level Medium Level High Level Code 5 6 mmho 0 ~ 19 to 0~ ~ 960 to 0 ~ ~ 351 to 0 ~ KPa 0 ~ 1.9 to 0 ~ ~ 9. to 0 ~ ~ 3.5 to 0 ~ ~ 5 V dc 50 ~550 ohm 0.5 Sec. Output Signal Isolation Turn-on Time ~ 0 ma dc /HART 500 Vrms (707V DC) 5 Sec.. Electrical Specifications Power Supply HART loop resistance Update Time 3. Performance Specifications (without seal) Operating Temp. LCD Meter Operating Temp. -0 ~ +5 C Humidity Limits 5% ~ 9% RH Ambient Temp. Effect ± 0.075% of Span (0.URLFSpan FURL) ± [ x(URL/Span)]% of Span (0.05URLFSpan<0.URL) ± [0.05%URL+0.15% Span]/ C Process Temp. Limit -0 ~ +05 C Stability ± 0.1% URL for 1 Months Power Supply Effects ± 0.005% of Span per Volt Static Pressure Effects ± 0.1% of URL per 7MPa (Zero Error) ± 0.% of Reading per 7Mpa (Span Error) Mounting Position Effects Zero Shift up to 350Pa No Span Effect Reference Accuracy -30 ~ +0 C. Physical Specifications Isolating Diaphragm Drain & Vent Valve Flange & Adapter O-ring Electronic Housing Bolts & Bolting Flange Viton, PTFE Aluminum 30 SST Process Connection Size Diaphragm Seal(Flush/Extended) Electrical Connections Weight (only transmitter) Pipe Stanchion Type bracket Housing Class 1/ - 1 NPT or 3 / 3 or 1/ 1 NPT with M 3.9 Kg Angle or Flat type Waterproof (IP67) 5. Hazardous Location Certifications Option Korea Standards Approval Flameproof Approval : Ex d IIC T6 (KOSHA) Intrinsic Safety Approval : Ex ia IIC T5 (KTL) Overseas Standards Approval CSA Explosion proof Approval FM Explosion proof Approval ATE Flame proof Approval
16 Dimensional Drawing (mm) MODEL 31LFD For Flush Diaphragm Seal and Direct Mount Type Transmitter Flange Size : 0mm (3 inch) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb D b d k b d k f D x 13 f d x Flange Size : 50mm ( inch) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb 59 D
17 Ordering Information MODEL NO. 31 Ranges Mounting Flange Size/Material Mounting Flange Rating Wetted Parts Material Diaphragm/Others Fill Fluid Materials of Construction Low Side Electrical Connection Hazardous Locations Certifications Option Code LFD 5 6 C S C3 S3 A1 A J1 J D1 D S PT H T 7 CS SS W N 1 K0 K1 K E1 *E C1 *C F1 *F M1 W C6 K Description Flush Diaphragm Seal and Direct Mount Type Transmitter 0-19 to 0-300mmHO (0-1.9 to KPa) to mmHO (0-9. to KPa) to mmHO (0-3.5 to KPa) -inch (50mm) C.Steel -inch (50mm) SST 3-inch (0mm) C.Steel 3-inch (0mm) SST ANSI Class 150 ANSI Class 300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 DIAPHRAGM OTHERS PTFE + Hastelloy C-76 Tantalum FILL FLUID TEMPERATURE LIMITS D.C Silicone 00-0 to 05 (-0 to 00 ) D.C Silicone 70 0 to 315 (3 to 600 ) FLANGE VENT/DRAIN VALVE C.Steel without Process Adapter (1/-1 NPT on the cover flange) with 1/-1 NPT Process Adapter () ELECTRICAL CONNECTION MATERIAL 1/-1NPT Epoxy Coated-Aluminum G1/ Epoxy Coated-Aluminum Maker Standard (Waterproof : IP67) KOSHA Flameproof Approval : Ex d IIC T6. KTL Intrinsic Safety Approval : Ex ia IIC ATE(KEMA) Flameproof ATE(KEMA) Intrinsic Safety CSA Explosion proof CSA Intrinsic Safety FM Explosion proof FM Intrinsic Safety LCD Indicator LP Lighting Protector SUS 30 Bolts and Nuts ET External Terminal Block Engineering Unit ST Stainless Steel Housing Oil Free Finish Order Note 1: Request to manufacturer for Draft Range, Absolute(small pressure and vacuum) ans items marked * before order.
18 MODEL 31LED Dimensional Drawing (mm) For Extended Diaphragm Seal and Direct Mount Type Transmitter Flange Size : 0mm (3 inch ) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb b d k D 150 b 0 d D f 1.6 D 17 D k 10.5 f D D Flange Size : 50mm ( inch ) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb 7 Diaphragm Extension Length Code R 50mm ( inch) 100mm ( inch) 150mm (6 inch)
19 Ordering Information MODEL NO. 31 Range Mounting Flange Size/Material Mounting Flange Rating Extension Length Wetted Parts Material Diaphragm/Others Fill Fluid Materials of Construction Low Side Electrical Connection Hazardous Locations Certifications Option Code -LED 5 6 x C S C3 S3 A1 A J1 J D1 D S PT H T 7 CS SS W N 1 K0 K1 K E1 *E C1 *C F1 *F M1 W C6 K Description Extended Diaphragm Seal and Direct Mount Type Transmitter 0-19 to 0-300mmHO (0-1.9 to KPa) to mmHO (0-9. to KPa) to mmHO (0-3.5 to KPa) -inch (50mm) C.Steel -inch (50mm) SST 3-inch (0mm) C.Steel 3-inch (0mm) SST ANSI Class 150 ANSI Class 300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 50mm (in.) 100mm (in.) 150mm (6in.) DIAPHRAGM OTHERS PTFE + Hastelloy C-76 Tantalum FILL FLUID TEMPERATURE LIMITS D.C Silicone 00-0 to 05 (-0 to 00 ) D.C Silicone 70 0 to 315 (3 to 600 ) FLANGE VENT/DRAIN VALVE Plated C.Steel without Process Adapter (1/-1 NPT on the cover flange) with 1/-1 NPT Process Adapter () ELECTRICAL CONNECTION MATERIAL 1/-1NPT Epoxy Coated-Aluminum G1/ Epoxy Coated-Aluminum Maker Standard (Waterproof : IP67) KOSHA Flameproof Approval : Ex d IIC T6. KTL Intrinsic Safety Approval : Ex ia IIC ATE(KEMA) Flameproof ATE(KEMA) Intrinsic Safety CSA Explosion proof CSA Intrinsic Safety FM Explosion proof FM Intrinsic Safety LCD Indicator LP Lighting Protector SUS 30 Bolts and Nuts ET External Terminal Block Engineering Unit ST Stainless Steel Housing Oil Free Finish Order
20 MODEL 31LFC Dimensional Drawing (mm) For Flush Diaphragm Seal and Capillary Type Transmitter Flange Size : 0mm (3 inch) Flange Rating Mb D b d k ANSI Class150 9 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 f d 17 x k f d x 9 DIN PN 5/0 Flange Size : 50mm ( inch) Flange Rating Mb ANSI Class150 D b ANSI Class300 d JIS 10K JIS 0K DIN PN 10/16 59 DIN PN 5/
21 Ordering Information MODEL NO. 31 Ranges Mounting Flange Size/Material Mounting Flange Rating Wetted Parts Material Diaphragm/Others Fill Fluid Code -LFC 5 6 x C S C3 S3 A1 A J1 J D1 D S PT H T 7 Capillary Length (m) Materials of Construction Electrical Connection Hazardous Locations Certifications Option CS SS 1 K0 K1 K E1 *E C1 *C F1 *F M1 W C6 K P BA BF CA CF Description Flush Diaphragm Seal and Capillary Type Transmitter (Two remote Seal) 0-19 to 0-300mmHO (0-1.9 to KPa) to mmHO (0-9. to KPa) to mmHO (0-3.5 to KPa) 50mm (-inch) C.Steel 50mm (-inch) SST 0mm (3-inch) C.Steel 0mm (3-inch) SST ANSI Class 150 ANSI Class 300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 DIAPHRAGM OTHERS PTFE + Hastelloy C-76 Tantalum FILL FLUID TEMPERATURE LIMITS D.C Silicone 00-0 to 05 (-0 to 00 ) D.C Silicone 70 0 to 315 (3 to 600 ) Capillary Length from 1 to 1mm (Example for 3m : 03) FLANGE VENT/DRAIN VALVE Plated C.Steel ELECTRICAL CONNECTION MATERIAL 1/-1NPT Epoxy Coated-Aluminum G1/ Epoxy Coated-Aluminum Maker Standard (Waterproof : IP67) KOSHA Flameproof Approval : Ex d IIC T6. KTL Intrinsic Safety Approval : Ex ia IIC ATE(KEMA) Flameproof ATE(KEMA) Intrinsic Safety CSA Explosion proof CSA Intrinsic Safety FM Explosion proof FM Intrinsic Safety LCD Indicator LP Lighting Protector SUS 30 Bolts and Nuts ET External Terminal Block Engineering Unit ST Stainless Steel Housing Oil Free Finish PVC Coating on SST Armored Stainless Steel Bracket (Angle type) with SST Bolts Stainless Steel Bracket (Flat type) with SST Bolts Painted Steel Mounting Bracket (Angle Type) with SST Bolts Painted Steel Mounting Bracket (Flat Type) with SST Bolts Order
22 Dimensional Drawing (mm) MODEL 31LEC For Extended Diaphragm Seal and Capillary Type Transmitter Flange Size : 0mm (3 inch ) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb D b d k b d k f 1.6 d 17 d5 76 x d5 x Flange Size : 50mm ( inch ) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb 7 D Diaphragm Extension Length Code f d R 50mm ( inch) 100mm ( inch) 150mm (6 inch)
23 Ordering Information MODEL NO. 31 Ranges Mounting Flange Size/Material Mounting Flange Rating Extension Length Wetted Parts Material Diaphragm/Others Fill Fluid Code -LEC 5 6 x C S C3 S3 A1 A J1 J D1 D S PT H T 7 Capillary Length (m) Materials of Construction Electrical Connection Hazardous Locations Certifications Option CS SS 1 K0 K1 K E1 *E C1 *C F1 *F M1 W C6 K P BA BF CA CF Description Extended Diaphragm Seal and Capillary Type Transmitter (Two Remote Seal) 0-19 to 0-300mmHO (0-1.9 to KPa) to mmHO (0-9. to KPa) to mmHO (0-3.5 to KPa) 50mm (-inch) C.Steel 50mm (-inch) SST 50mm (-inch) C.Steel 50mm (-inch) SST ANSI Class 150 ANSI Class 300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 50mm (in.) 100mm (in.) 150mm (6in.) DIAPHRAGM OTHERS PTFE + Hastelloy C-76 Tantalum FILL FLUID TEMPERATURE LIMITS D.C Silicone 00-0 to 05 (-0 to 00 ) D.C Silicone 70 0 to 315 (3 to 600 ) Capillary Length from 1 to 1mm (Example for 3m : 03) FLANGE VENT/DRAIN VALVE Plated C.Steel ELECTRICAL CONNECTION MATERIAL 1/-1NPT Epoxy Coated-Aluminum G1/ Epoxy Coated-Aluminum Maker Standard (Waterproof : IP67) KOSHA Flameproof Approval : Ex d IIC T6. KTL Intrinsic Safety Approval : Ex ia IIC ATE(KEMA) Flameproof ATE(KEMA) Intrinsic Safety CSA Explosion proof CSA Intrinsic Safety FM Explosion proof FM Intrinsic Safety LCD Indicator LP Lighting Protector SUS 30 Bolts and Nuts ET External Terminal Block Engineering Unit ST Stainless Steel Housing Oil Free Finish PVC Coating on SST Armored Stainless Steel Bracket (Angle type) with SST Bolts Stainless Steel Bracket (Flat type) with SST Bolts Painted Steel Mounting Bracket (Angle Type) with SST Bolts Painted Steel Mounting Bracket (Flat Type) with SST Bolts Order
24 Dimensional Drawing (mm) MODEL 31LFS For Flush Diaphragm Seal and Capillary Type Transmitter Flange Size : 0mm (3 inch) Flange Rating Mb D b d k ANSI Class150 f 9 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 d x Dimensional Drawing (mm) Flange Rating ANSI Class150 Mb b DIN PN 5/0 k f d x JIS 0K DIN PN 10/16 d ANSI Class300 JIS 10K D
25 Ordering Information MODEL NO. Code 31 -LFS Ranges Mounting Flange Size/Material Mounting Flange Rating Wetted Parts Material Diaphragm/Others Fill Fluid 6 7 x C S C3 S3 A1 A J1 J D1 D S PT H T 7 Capillary Length (m) Materials of Construction Electrical Connection Hazardous Locations Certifications Option CS SS 1 K0 K1 K E1 *E C1 *C F1 *F M1 W C6 K P BA BF CA CF Description Flush Diaphragm Seal and Capillary Type Transmitter (One Remote Seal) to mmHO (0-3.5 to KPa) to mmHO ( to 0-06 KPa) to mmHO (0-3. to KPa) 50mm (-inch) C.Steel 50mm (-inch) SST 0mm (3-inch) C.Steel 0mm (3-inch) SST ANSI Class 150 ANSI Class 300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 DIAPHRAGM OTHERS PTFE + Hastelloy C-76 Tantalum FILL FLUID TEMPERATURE LIMITS D.C Silicone 00-0 to 05 (-0 to 00 ) D.C Silicone 70 0 to 315 (3 to 600 ) Capillary Length from 1 to 1mm (Example for 3m : 03) FLANGE VENT/DRAIN VALVE Plated C.Steel ELECTRICAL CONNECTION MATERIAL 1/-1NPT Epoxy Coated-Aluminum G1/ Epoxy Coated-Aluminum Maker Standard (Waterproof : IP67) KOSHA Flameproof Approval : Ex d IIC T6. KTL Intrinsic Safety Approval : Ex ia IIC ATE(KEMA) Flameproof ATE(KEMA) Intrinsic Safety CSA Explosion proof CSA Intrinsic Safety FM Explosion proof FM Intrinsic Safety LCD Indicator LP Lighting Protector SUS 30 Bolts and Nuts ET External Terminal Block Engineering Unit ST Stainless Steel Housing Oil Free Finish PVC Coating on SST Armored Stainless Steel Bracket (Angle type) with SST Bolts Stainless Steel Bracket (Flat type) with SST Bolts Painted Steel Mounting Bracket (Angle Type) with SST Bolts Painted Steel Mounting Bracket (Flat Type) with SST Bolts Order
26 Dimensional Drawing (mm) MODEL 31LES For Extended Diaphragm Seal and Capillary Type Transmitter Flange Size : 0mm (3 inch ) Flange Rating Mb ANSI Class150 D b d k DIN PN 10/ d 17 d5 x b d k f d d x ANSI Class300 JIS 10K JIS 0K f 0 DIN PN 5/0 Flange Size : 50mm ( inch ) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb 7 D Diaphragm Extension Length Code R 50mm ( inch) 100mm ( inch) 150mm (6 inch)
27 Ordering Information MODEL NO. Code 31 -LES Ranges Mounting Flange Size/Material Mounting Flange Rating Extension Length Wetted Parts Material Diaphragm/Others Fill Fluid 6 7 x C S C3 S3 A1 A J1 J D1 D S PT H T 7 Capillary Length (m) Materials of Construction Electrical Connection Hazardous Locations Certifications Option CS SS 1 K0 K1 K E1 *E C1 *C F1 *F M1 W C6 K P BA BF CA CF Description Extended Diaphragm Seal and Capillary Type Transmitter (One Remote Seal) to mmHO (0-3.5 to KPa) to mmHO ( to 0-06 KPa) to mmHO (0-3. to KPa) 50mm (-inch) C.Steel 50mm (-inch) SST 50mm (-inch) C.Steel 50mm (-inch) SST ANSI Class 150 ANSI Class 300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 50mm (in.) 100mm (in.) 150mm (6in.) DIAPHRAGM OTHERS PTFE + Hastelloy C-76 Tantalum FILL FLUID TEMPERATURE LIMITS D.C Silicone 00-0 to 05 (-0 to 00 ) D.C Silicone 70 0 to 315 (3 to 600 ) Capillary Length from 1 to 1mm (Example for 3m : 03) FLANGE VENT/DRAIN VALVE Plated C.Steel ELECTRICAL CONNECTION MATERIAL 1/-1NPT Epoxy Coated-Aluminum G1/ Epoxy Coated-Aluminum Maker Standard (Waterproof : IP67) KOSHA Flameproof Approval : Ex d IIC T6. KTL Intrinsic Safety Approval : Ex ia IIC ATE(KEMA) Flameproof ATE(KEMA) Intrinsic Safety CSA Explosion proof CSA Intrinsic Safety FM Explosion proof FM Intrinsic Safety LCD Indicator LP Lighting Protector SUS 30 Bolts and Nuts ET External Terminal Block Engineering Unit ST Stainless Steel Housing Oil Free Finish PVC Coating on SST Armored Stainless Steel Bracket (Angle type) with SST Bolts Stainless Steel Bracket (Flat type) with SST Bolts Painted Steel Mounting Bracket (Angle Type) with SST Bolts Painted Steel Mounting Bracket (Flat Type) with SST Bolts Order
28 Smart Transmitter with Diaphragm Seal Direct Mount MODELType 31LFD/LED Two Remote MODELType 31LFC/LEC One Remote MODELType 31LFS/LES
29 Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL 300
30 Standard Flush Mount SST Housing Description of Product Function The 3 Smart Pressure Transmitter is a micro processorbased high performance transmitter, which has flexible pressure calibration and output, automatic compensation of ambient temperature and process variable, configuration of various parameters, communication with HART protocol. All Data of Sensor (Tag No., type, range etc.) is to be input, modified and stored in EEPROM.» Flexible Sensor Input : GP, AP, Flush Mount» Various Output : ~ 0mA, Digital Signals» Setting Various Parameters : Zero/Span, Trim, Unit, Fail-mode, etc.» Self Diagnostic Function : Sensor, Memory A/D Converter, Power, etc.» Digital Communication with HART protocol» Explosion-proof Approval & Intrinsic Safety Approval : ATE,FM, FM Canada, GOST, KOSHA, KTL, etc.» Marine Certificate : ABS, LR, BV, DNV Functional Block Diagram Sensor Part A/D Conversion EEPROM Piezoelectric Sensor * Gauge Pressure * Absolute Pressure MCU Part Microprocessor Input Sensor Value Engineering Units Re-range (Zero / Span) Zero Point Adjustment DA Trimming Damping / Filtering LCD Engineering Mode Diagnostics Self Compensation Communications LCD Display Configuration Data ~0m A DAC HART HART Protocol with Host
31 Features Function» Superior Performance High Accuracy : ±0.075% of Calibrated Span (option : ±0.0% of Calibrated Span) Long-Term Stability High Rangeability (100:1)» Range and Sensor Limits Refer to Table 1.» Zero and Span Adjustment Limits Zero and span values can be set anywhere within the range limits stated in Table 1. Span must be greater than or equal to the minimum span stated in Table 1.» Flexibility Measuring GP, AP Data Configuration with HART configurator» Reliability Continuous Self-Diagnostic Function Automatic Ambient Temperature Compensation Fail-mode Process Function EEPROM Write Protection CE EMC Conformity Standards (EN5001-, EN500-) Transmitter Description 3 Pressure transmitter can be easily configured from any host that support the HART protocol.» Basic Setup Operational Parameters. ~0mA Points (Zero/Span) Damping Time : 0.5 ~ 60 sec Tag : alphanumeric characters Descriptor : 16 characters Message : 3 characters. Date : day/month/year» Calibration and Trimming Lower/Upper Range (zero/span) Sensor Zero Trimming Zero Point Adjustment DAC Output Trimming Transfer Function Self-Compensation» Self-Diagnosis and Others CPU & Analog Module Fault Detection Communication Error Fail-mode Handling LCD Indication Temperature Measurement of Sensor Module» Output (Analog Current and Digital Data) Two wire ~0mA user-configurable for linear. digital process value superimposed on ~0mA signal, available to any host that conforms to the HART protocol» Power Supply & Load Requirement External power supply required. Transmitters operate on 1 to 5Vdc * 50 ohm load Vdc * up to a 550 ohm load -- Vdc Max. Loop Resistance = ( E - 1 ) / 0.0 (E = Power Supply Voltage) Voltage Range : 1 to 5 Vdc Voltage Rating : Vdc ±30% Loop Load 0 ~ 1500 ohm -- Operation 50 ~ 550 ohm -- HART Communications» EMC Conformity Standards EMI (Emission) EN5001-:1993 EMS (Immunity) EN500-:1995» Failure Mode Fail High : Current 1.1 ma Fail Low : Current 3.7 ma» Storage Temperature -0 C to 5 C (without condensing)» Process Temperature Limits (Range codes and approval codes may effect limits) -0 C to 10 C ( -10 to )» Isolation Input/output isolated to 500Vrms (707 Vdc)» Working Pressure Limits (silicone oil) Model G -100 ~ 300KPa - # ~ 3000 KPa - # 0 ~ 10,500KPa - # 5 0 ~ 0,000 KPa - # 6 0 ~ 75,000 KPa - # 7 Model A 0 ~ 55 KPa - # 0 ~ 3000 KPa - # 5 0 ~ 550 KPa - # 6
32 Physical Specifications Function» Wetted Materials Isolating Diaphragms :, Tantalum, HAST-C» Non-wetted materials Fill Fluid : Silicone oil (DC00) Electronics Housing : Aluminum, SST316L(option) Flameproof and Waterproof (IP67) Cover O-ring : Buna-N Paint : Epoxy-Polyester or Polyurethane Mounting Bracket : 30SST with U-bolt (30SST) for -inch pipe Nameplate : 30 SST» Process Connections 1/-1 NPT Female 1/-1 NPT (option)» Electrical connections 1/-1 NPT conduit with M Screw Terminals» Change main parameter by Button Change Unit Change Upper range value Change Lower range value Change the Damping Second Select the Decimal Place Zero Trim Zero Adjustment» 5 Digit LCD Express all pressure unit. Use 5 digit. Select decimal place (0 to ) User define unit function Hazardous Location Certifications» KOSHA Approvals K1 Code : * KOSHA: Korea Occupational Safety & Health Agency Flameproof for Class I, Zone 1 : Ex d IIC T6, IP67 Ambient Temperature : -0 to 60 C Max. Process Temperature : 0 C Power Supply : Max. 5 Vdc Output : to 0 ma + HART, Max. ma» ATE Approvals E1 Code : CE 03 II G Ex d IIC T6, T5 or T Operating Temperature: -0 C Tamb +60 C T6 for process 5 C ; T5 for process 100 C T 130 C 3 ATE Certification is according to the below standards : EN : 006 EN : 007» KTL Certification K Code : * KTL: Korea Testing Laboratory Intrinsic Safety: Ex ia IIC T6 Ambient Temperature : -0 to 60 C Ui=30Vdc, Ii=00mA, Pi=0.9W, Ci=7nF, Li=9μH» FM & FM Canada Approvals F1 Code : * FM: Factory Mutual explosion proof * FM Canada: Canadian requirements Explosion proof for Class I, Division 1 Groups A, B, C and D Dust-ignition proof for Class II, Division 1, Groups E, F and G Dust-ignition proof for Class II, Division 1 T6, see instruction for temperature code if process temperature above 5 C Ambient Temperature : -0 to 60 C Enclosure: indoors and outdoors, NEMA Type Conduit seal required within 1 for Group A only. Nonincendive for Class I, Division, Groups A, B, C & D; Class II, Division, Groups E, F & G; and Class III, Division 1, Temperature Code T Ambient Temperature : -0 to 60 C Enclosure: indoors and outdoors, NEMA Type Moving within Menu : Zero Moving to below Menu : Span Moving Top Menu : Zero+Span
33 Connection Diagram of Signal, Power, HHT for Transmitter Exploded Drawing of Model 3
34 General Specification 1. Model 3 G/APressure Sensor Range (Rangeability = 100 : 1) Range (KPa) -100~ ~ 1,500 0 ~ 5,000 0 ~ 5,000 0 ~ 60,000 3 G Calibrated Span (KPa) 1.5~ ~ 1, ~ 5, ~ 5, ~ 60, A Range 0 ~ 50 0 ~ 1,500 0 ~,500.5 ~ ~ 1,500 5 ~,500. Electrical Specifications 1 to 5 Vdc 50 ~ 550 ohm Power Supply HART Loop Resistance Output Signal Isolation ~ 0 ma dc / HART 500 Vrms (707 Vdc) 3. Performance Specifications Reference Accuracy Ambient Temp. Effect ± 0.075% of Span (0.1URL Span URL) ± [ x(URL/Span)]% of Span (0.01URL Span<0.1URL) ± [0.019%URL+0.15% Span] / 0C Ambient Temperature -0 C ~ +5 C LCD Meter Ambient Temp -30 C ~ + 0 C Humidity Limits 5% ~ 100% RH Process Temp. Limit -0C ~ +10 C Power Supply Effect ± % of Span per Volt Stability ± [0.15%URL for 36 months. Physical Specifications Isolating Diaphragm Electronic Housing Aluminum Housing Class Waterproof (IP67) Process Connection Size Electrical Connections Pipe Stanchion Type Bracket Weight (excluding options) 1/ 1 NPT Female 1/ 1 NPT with M Angle or Flat type 1.7 kg (standard).3kg(sst Housing)
35 Ordering Information MODEL 300 Range Mounting Flange Material Hazardous Location Certifications Fill Fluid Process Connection Electrical Connection Option Code -G -F -H M11 *M1 *M13 *M1 K0 K1 E1 F1 1 * S O 1 M1 LPI K W BA BF ST Description Gauge Pressure Transmitter (reference accuracy : % of span ) Flush Mount Pressure Transmitter Absolute Pressure Transmitter (reference accuracy : % of span) G/F A Range (KPa) Min.Span (KPa) Range (KPa) Min. Span (KPa) -100~ ~ 1, ~ ~ 5, ~ ~ 5, ~ ~ 60, DIAPHRAGM OTHER HAST-C Tantalum HAST - C HAST-C Maker Standard (Waterproof : IP67 ) KOSHA Flameproof Approval KTL Intrinsic Safety Approval K ATE (KEMA) Exposion proof ATE(KEMA) Intrinsic Safety E FM & FM Canada Explosion proof FM & FM Canada Intrinsic Safety F Silicone (DC 00) Inert fill (Halocarbon Oil) 1/ 1 NPT Female (standard) 1/ - 1 NPT Female (adapter) 1/-1NPT Epoxy-Polyester Painted Aluminum G1/ Epoxy-Polyester Painted Aluminum (Adapter) LCD Indicator Lightening Protector (Internal) Lightening Protector (External) LPE Oil Free Finish way manifold Remote type Stainless Steel Bracket (Angle type) with SST Bolts Stainless Steel Bracket (Flat type) with SST Bolts Stainless Steel Housing Example : 3-G5-M11-K0-1-S-1-M1 Note 1 : Request to manufacturer for Draft Range, Absolute (small pressure and vacuum) and Items marked * before order.
36 Dimension of Transmitter (mm) Standard Model Flush Mount Model Intrinsically Safe Model
37 Smart Temperature Transmitter MODEL 1 &
38 Model 1 Model Description of Product Function The Smart Temperature Transmitter is a microprocessor-based high performance transmitter, which has flexible sensor input and output, automatic compensation of ambient temperature and process parameters, configuration of various parameters, communication with HART protocol. All Data of Sensor (Tag No., type, range etc.) is to be input, modified and stored in EEPROM.»Flexible Sensor input: RTD, T/C, mv, Ohm»Various output: ~0mA(Analog), Digital Signals»Automatic Compensation by Linearization table in which user can modify the various necessary values»automatic Compensation of Ambient Temperature»Setting Various Parameters: Zero/Span, Unit, Fail-mode, Trim, etc.»self Diagnostic Function: Sensor, A/D Converter, Memory, Power, etc.»digital Communication with HART protocol»flameproof Approval and Intrinsic Safety Approval: KOSHA, KTL,ATE,FM, GOST(1)»Marine Certificate: ABS, LR, DNV, BV FUNCTIOL BLOCK DIAGRAM SensorADC Part Sensor Cold Junction Compensation User-Selectable Temperature Sensor RTD (W, 3W, W) T/C (Thermocouple) mv Ohm Isolation MCU Part Microprocessor Range Value (Zero/Span) Input Sensor Value Engineering Units Damping / Filtering Linearization Table Zero Point Adjustment DA Trimming Self Compensation Configuration Data Diagnostics LCD Display HART Communications ~0mA DAC HART HART Protocol with Host
39 Features» Superior Performance Excellent Accuracy (Refer to Page ) Long-Term Stability (Refer to Page )» Flexibility Selection of various T/C, RTD, mv, Ohm Data Configuration with HART configurator Transmitter Description» Sensor Inputs The model 1 and are compatible with a variety of temperature sensors, including W, 3W and Wire RTDs, thermocouples, and other resistance and millivolt inputs (see Page 6). The sensor part module converts the temperature sensor into the digital value. The MCU module calculates the process temperature value based on the digital value. The sensor type and configurationare software-selectable using the Hand-Heldterminal and PC configurator. The sensor modules include the following features The software of the transmitter compensates for the thermal effects, improving performance. Precise input compensation during operation Is achieved with temperature and voltage or resistance correction coefficients that are characterized over the range of temperature sensor and stored in the EEPROM memory. Input sensor type - RTD (Pt-100 ohm): W, 3W, Wire - Thermocouple: B, E, J, K, N, R, S, T type - mv: -10 ~ 75mV - Ohm: 0 ~ 30 Ω» Reliability Automatic Compensation: Linearization of sensor input, Ambient temperature compensation Continuous Self Diagnostic Fail-mode Process function EEPROM Write Protection I/O Isolation: Grounded Thermocouple CE EMC Conformity Standards (EN5001-,EN500-)» Basic Setup Temperature Transmitter can be easily configured from any host that support the HART protocol. Configuration consists of setting the following transmitter operational parameters. Sensor Type Number of sensor input wires and 0mA Points (Zero/Span) Engineering Units Damping Time Tag: alphanumeric characters Descriptor: 16 characters Message: 3 characters Date: day / month / year» Calibration and Trimming Lower/Upper Range (zero/span) Sensor Linearization Zero Point Adjustment DAC Output Trimming Self-Compensation» Self-Diagnosis and Others CPU & Analog Module Fault Detection Communication Error Fail-mode Handling LCD Indication (for model 1) Model 1 Transmitter Field Wiring and Sensor Wiring Diagrams
40 Performance Specifications Function Specifications» Reference Accuracy (Refer to Table 1)» Range and Sensor Limits (Refer to Table 1)» Stability RTDs. ±0.1% of Reading or 0.15 C, whichever is greater, for months Thermocouples ±0.1% of Reading or 0.15 C, whichever is greater, for 1 months» Zero and Span Adjustment Limits Zero and span values can be set anywhere within the range limits stated in Table 1. Span must be greater than or equal to the minimum span stated in Table 1» Output (Analog Current and Digital Data) Two wire ~0mA, Digital process value superimposed on ~0mA signal, available to any host that conforms to the HART protocol» Repeatability ±0.05% of span» Ambient Temperature Effect (per 1 C change in ambient temperature. Sensor Type Pt 100(a=0.0035) Pt 100(a= ) NIST Type B NIST Type E, J, K, N NIST Type R, S, T Digital Accuracy W, 3W, Wire RTD C Thermocouple 0.06 C C % of reading D/A effect 0.00% of Span 0.00% of Span C If reading 00 C 0.01 C % of reading if not» Power Supply Effect Less than ±0.005% of Span per Volt» Update Time and Turn-On Time Update Time: 0.5 seconds Turn-On Time: 5 seconds» Failure Mode The value to which the transmitter drives its output in failure is as follows Fail High: Current 1.75 ma Fail Low: Current 3.75 ma» Power Supply & Load Requirement External power supply required. * 50 ohm load Vdc * up to a 550 ohm load -- Vdc Max. Loop Resistance = (E-1) / 0.0 (E = Power Supply Voltage) Voltage Range: 1 to 5 Vdc Voltage Rating: Vdc ±30%» Loop Load 0 to 1500 Ω for Operation 50 to 550 Ω for HART Communications» Ambient Humidity Limits 5% ~ 100%RH (Relative Humidity)» Ambient Temperature Limits -0 C ~ 5 C (without condensing for model 1) -0 C ~ 5 C (without condensing for model ) -30 C ~ 0 C (with LCD module)» Storage Temperature -0 C ~ 5 C (without condensing) -0 C ~ 5 C (without condensing for model )» Isolation Input / output isolated to 500Vrms (707 Vdc)
41 Physical Specifications Hazardous Location Certifications» Electrical connections 1/-1 NPT conduit with M3.5 Screw Terminals» KOSHA Approvals K1 Code : * KOSHA: Korea Occupational Safety & Health Agency Flameproof for Class I, Zone 1 : Ex d IIC T6, IP67 Ambient Temperature: -0 to 60 C Power Supply: Max. 5 Vdc Output: to 0 ma + HART, Max. ma» Materials of Construction Electronics Housing: Low-copper aluminum Flameproof and waterproof (IP67) Paint: Epoxy-Polyester or Polyurethane Cover O-ring: Buna-N Mounting Bracket: 30SST with U-bolt (30SST) for -inch pipe Nameplate: 30 SST» Weight 1. kg below (Standard-excluding options).6kg (SST Housing-excluding options)» ATE Approvals E1 Code : CE 03 II G Ex d IIC T6, T5 or T Operating Temperature: -0 C Tamb +60 C T6 for process 5 C; T5 for process 100 C T for process 130 C FM & FM Canada Approvals F1 Code : * FM: Factory Mutual explosion proof * FM Canada: Canadian requirements Explosion proof for Class I, Division 1 Groups A, B, C and D Dust-ignition proof for Class II, Division 1, Groups E, F and G Dust-ignition proof for Class II, Division 1 T6, see instruction for temperature code if process temperature above 5 C Ambient Temperature: -0 to 60 C Enclosure: indoors and outdoors, NEMA Type Conduit seal required within 1 for Group A only. Nonincendive for Class I, Division, Groups A, B, C & D; Class II, Division, Groups E, F & G; and Class III, Division 1, Temperature Code T Ambient Temperature: -0 to 60 C Enclosure: indoors and outdoors, NEMA Type Supply Voltage:11.9~Vdc Model Transmitter Field Wiring and Sensor Wiring Diagrams
42 General Specifications 1. Temperature Sensor Range & Accuracy Sensor Type Sensor Reference Input Range Minimum Span Digital Accuracy D/A Accuracy Of Span RTD KSC (a=0.0035) DIN JISC (a= ) Pt-100 Pt ~ 650 C ±0.17 C 15 C -00 ~ 650 C ±0.03% ±0.16 C Thermocouple NIST Type B 100 ~ 1,0 C ±0.77 C NIST Type E 00 ~ 1,000 C ±0.0 C NIST Type J 00 ~ 1,00 C ±0.5 C NIST Type K 00 ~ 1,350 C ±0.35 C KSC C NIST Type N 00 ~ 1,300 C ±0.0 C NIST Type R 0 ~ 1,760 C ±0.60 C NIST Type S 0 ~ 1,70 C ±0.50 C NIST Type T -00 ~ 00 C ±0.5 C Millivolt Input -10 ~ 75 mv mv ± 0.01 mv Ohm Input 0 ~ 30 Ω 0 Ω ± 0.35 Ω < Note > 1) RTD input: a= : KS, JIS, DIN, IEC, a= : US. ) Thermocouple input: KSC , JISC , ANSI MC ) Digital accuracy for Type B is ± 3.0 C from 100 to 300 C ) Digital accuracy for Type K is ± 0.50 C from -10 to -90 C ±0.03% Ambient Temperature Effects ( per 1 C change in Ambient temperature) Sensor Type Digital Accuracy D/A effect per Pt 100 (a=0.0035) C RTD w, 3w, -Wire Pt 100 (a= ) NIST Type B 0.06 C 0.00% of Span NIST Type E, J, K, N C % of reading Thermocouple C If reading NIST Type R, S, T 0.01 C % of reading if not. Electrical Specifications Power Supply HART Loop Resistance Voltage Range : 1 to 5 Vdc Voltage Rating : Vdc ±30% 50 ~ 550 ohm( Vdc) Output Signal ~ 0 ma dc / HART Isolation 500 Vrms (707 Vdc) 3. Performance Specifications Accuracy Stability for year Ambient Temp. Effect Repeatability Refer to item No.1 ±0.1% of Reading or 0.1 C whichever is greater ±0.05% of Span/10 C ±0.05% of Span Operating Temp LCD Meter Operating Tem -0 ~ +5 C -30 ~ +0 C Humidity Limits Power Supply Effect 5% ~ 100% RH(1) ±0.005% of Span/V Weight (excluding Option Items) Pipe Stanchion Type bracket Housing Class 1.Kg below (standard).6kg (SST Housing) Angle or Flat Type Waterproof (IP67). Physical Specifications (for model 1) Electrical Connections 1/-1NPT(w/M3.5) Electronics Housing O-rings Aluminum Buna-N
43 Ordering Information MODEL NO. Code -S Single Element Model 1 -D* Dual Elements Housing Materials and Electrical Connection 1 1/ - 1 NPT G1/ (Adapter) 1 1/ - 1 NPT Epoxy Coated-Aluminum G1/ (Adapter) Epoxy Coated-Aluminum H Horizontal Type V Vertical Type Process Connection Sensor Position Sensor Type Hazardous Locations Certifications Option R M Mili-volt K0 Maker Standard (Waterproof : IP67) K1 KOSHA Flameproof Approval : Ex d IIC T6. K KTL Intrinsic Safety Approval : Ex ia IIC T5 E1 ATE Flameproof F1 FM & FM Canada Explosion proof *F M1 FM & FM Canada Intrinsic safety LCD Indicator BA Stainless Steel Bracket (Angle type) with SST Bolts BF Stainless Steel Bracket (Flat type) with SST Bolts ST Stainless Steel Housing Code -S -D* Housing Materials Hazardous Locations Certifications Sensor Type Sensor Fail Mode Ex) : -S-1-K0-A3-D Note : * before order. Epoxy Coated-Aluminum Epoxy Coated-Aluminum RTD (PT100[Ω]) / (with Wires) Thermocouple / (with Type) Resistor A T 1 LPE Example : 1-S-K1-1-1-H-A3-M1-BA Note 1 : * before order. MODEL NO. Model Description Assembly Option (Element/Well) Lightening Protector (External) Description Single Element Dual Element ( Order, Request to manufacturer if necessary) 1 Plastic KO Maker Standard A RTD (PT100[Ω]) / (with Wires) T Thermocouple / (with Type) R Resistor M Mili-volt D Downscale U Upscale
44 Connection Diagram of Signal, Power, HHT for Transmitter Dimension Dimensions of Transmitter (mm) Model 1 Model
45 Distributor: Bont Technologies GmbH Salzstr: Lüneburg info@bont-tech.com
APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A
Doc. No. : C3100-E05A Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com Smart Pressure Transmitter APT3100 Standard Description
More informationDOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200
DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The
More informationSmart Pressure Transmitter
DOC. NO. : C3200-E05A Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of smart transmitter brand series
More informationSmart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement
Doc. No. : C3100-E05A FM APPROVED Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of
More informationAPT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL
WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America
More informationSeries Smart Pressure Transmitter
www.tek-trol.com TEK-BAR 3100 Series Smart Pressure Transmitter www.tek-trol.com 2 Introduction The Tek-Bar series of smart transmitters have excellent stability, high accuracy and include features that
More informationPAD - Heavy Duty Differential Pressure Trasmitter
Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:
More informationAPT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement
For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationATT2100/2200 SMART TEMPERATURE TRANSMITTER. Application Areas: ATT 2200 ATT2100
SMRT TEMPERTURE TRNSMITTER TT 2200 pplication reas: Nuclear Water & Wastewater Chemical Petrochemical Oil & Gas Pulp & Paper Food & Beverage Pharmaceutical Power Renewable Energy lternate Fuel utrol merica
More informationRosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS
Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process
More informationGeneral Specifications
General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC
More informationMODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
More informationSMART TEMPERATURE TRANSMITTERS. smar
SMART TEMPERATURE TRANSMITTERS FEATURES Single unit accepts signal from: - Standart RTDs and Thermocouples - Single ended or differential sensing - mv signals from radiation pyrometers, load cells, etc.
More informationMonocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS
DRS 300 1 Monocrystalline silicon smart differential pressure transmitter DRS300 High stability Detailed Information application the flow of gas, vapor and liquid measurement with device (volume or mass
More informationABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)
ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) DATA SHEET FKH...5 The FCX AIII absolute pressure transmitter (Direct mount type) accurately measures absolute pressure and transmits proportional 4 to
More informationThe Rosemount 848T Wireless Temperature Transmitter
Rosemount 88T Family February 0 The Rosemount 88T Wireless Temperature Transmitter The Rosemount 88T is the premier choice for Wireless High Density measurements. Four independently configurable inputs
More informationGeneral Specifications
General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure
More informationField IT 2600T Series Pressure Transmitters
Data Sheet Field IT 2600T Series Pressure Transmitters Model 364GS Gauge Model 364AS Absolute standard overload Best in class total performance long term stability of 0.25% for 10 years base accuracy of
More informationAlphaline Temperature Transmitters
Alphaline Temperature Transmitters Accepts RTD and thermocouple inputs Available with an integral meter Dual compartment housing provides the highest reliability in harsh industrial environments Offers
More information2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor
INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter Features Include Base accuracy : ±0.075% Span limits 0.134 to
More informationDRS390 High stability, flange mounting
DRS 390 1 Monocrystalline silicon smart differential pressure transmitter DRS390 High stability, flange mounting Detailed Information Application the flow of gas, vapor and liquid measurement with device
More informationGeneral Specifications
General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to
More informationAT9000 Advanced Transmitter Differential Pressure Transmitters
AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable
More informationA New Generation of Pressure Transmitters
Fuji Electric Instrumentation & Control A New Generation of Transmitters ECNO : 610d A New addition to the FCX Family at the edge of Technology As a leader in the field of pressure measurement, Fuji Electric
More informationGeneral Specifications
General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC
More informationGeneral Specifications
General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal
More informationModel 3244MV MultiVariable Temperature Transmitter with Profibus-PA
Easy integration to a Profibus DP network 5-year stability reduces maintenance costs Dual-compartment housing provides the highest reliability in harsh industrial environments 18-bit analog-to-digital
More informationAT9000 Advanced Transmitter Gauge Pressure Transmitters
AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable
More informationThe SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.
The SFC 1000 P2DAAA is a dual meter run bidirectional flow computer with a built in Rosemount 205 Multivariable Transmitter (DP, P, and TEMP) for the measurement of liquid & Gas products. Using orifice
More information600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)
Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically
More informationGeneral Specifications
General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus
More informationA New Generation of Pressure Transmitters
e-front runners A New Generation of Transmitters SeriesAII/CII ECNO : 610d A New addition to the FCX Family at the edge of Technology As a leader in the field of pressure measurement, Fuji Electric has
More informationA New Generation Of Pressure Transmitters -AII V5. ECNO : 610e
A New Generation Of Pressure Transmitters -AII V5 ECNO : 610e A New Transmitter at the edge of Technology As a leader in the field of measurement, Fuji Electric has an installed base of more than 1 000
More informationFlow Level Temperature Pressure Valves Analyzers Accessories TekValSys
Technology Solutions www.tek-trol.com 796 Tek Drive Crystal Lake, IL 60014 USA Tel: +1 847 857 6076, +1 847 655 7428 Fax: +1 847 655 6147 Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys
More informationFUNCTIONAL SPECIFICATIONS
DATA SHEET The ProcessX differential pressure (flow) transmitter accurately measures differential pressure, liquid leel, gauge pressure or fl ow rate and transmits a proportional 4 to 20mA signal. The
More informationAT9000 Advanced Transmitter Gauge Pressure Transmitters
AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable
More informationSpecifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span
PERFORMANCE SPECIFICATIONS Reference Accuracy (1) Specifications Total Performance is based on combined errors of reference accuracy, ambient temperature effect, and static pressure effect. This product
More informationDifferential Pressure Transmitters
AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable
More informationGeneral Specifications
General Specifications YTA0, YTA0 Temperature Transmitter [Style: S] The YTA0 and YTA0 are the highly accurate temperature transmitters that accept Thermocouple, RTD, ohms or DC milivolts inputs and converts
More informationURV LRV. Smart Field Communicator. Can be ordered separately see specification 34-ST-03-55
ST 3000 Smart Transmitter Series 900 Differential Pressure Models STD924 0 to 400 inh 2 O 0 to 1,000 mbar STD930 0 to 100 psi 0 to 7,000 mbar STD974 0 to 3000 psi 0 to 210,000 mbar Function 34-ST-03-65
More informationA New Generation Of Pressure Transmitters -AII V5. ECNO : 610f
A New Generation Of Pressure Transmitters -AII V5 ECNO : 610f A New Transmitter at the edge of Technology - - - - - -AII V5 2 - Approvals Fieldbus (FF) Protocols TM Hart /Fuji (bilingual) PROFIBUS The
More informationLGP Design. Can be ordered separately see specification 34-ST-03-55
ST 3000 Smart Transmitter Series 900 Gauge Pressure Models STG944 0 to 500 psi 0 to 35 STG94L 0 to 500 psi 0 to 35 STG974 0 to 3000 psi 0 to 210 STG97L 0 to 3000 psi 0 to 210 STG98L 0 to 6000 psi 0 to
More informationPTG series Smart Pressure Transmitter
No. SS2-PTG300-0100 PTG series Smart Pressure Transmitter Model PTG71 / PTG72 OVERVIEW The Smart Pressure Transmitter model PTG is a high- performance, highly reliable gauge pressure transmitter. Based
More informationGeneral Specifications
General Specifications EJA440E Gauge Pressure Transmitter The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam.
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationABSOLUTE PRESSURE TRANSMITTER
ABSOLUTE PRESSURE TRANSMITTER DATA SHEET FKA...5 The FCX -AIII absolute pressure transmitter accurately measures absolute pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes
More informationCompact Orifice Flow Meter
Data Sheet DS/OM Issue 2 Compact Orifice Flow Meter OriMaster Integrated DP Flow measurement system combines primary element with DP Transmitter in a single flowmeter assembly One-piece flowmeter, pressure
More informationRosemount 2088 Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS
Product Data Sheet Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS Absolute and gage pressure ranges from 0 1.5 psi to 0 4,000 psi (0 0.1 to 0
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationModel 3244MV. MultiVariable Temperature Transmitter with Profibus PA. Product Data Sheet
Product Data Sheet 00813-0100-4799 Model 3244MV MultiVariable Temperature Transmitter with Profibus PA PROFIBUS PA CAPABILITIES CanbeintegratedtoaProfibusDPnetwork Reduces wiring costs and installation
More informationGeneral Specifications
General Specifications EJA310E Absolute Pressure Transmitter The high performance absolute transmitter EJA310E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or
More informationGeneral Specifications
General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to
More information3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.
Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationGeneral Specifications
General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC
More informationAT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model
AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability.
More information600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet
Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration
More informationModel 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet
Product Data Sheet 00813-0101-4796 Model 144H PC-Programmable Temperature Transmitter FEATURES Configurable using the Model 144C Configuration Interface hardware and software Programmable via standard
More informationGeneral Specifications
General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationPRODUCT SPECIFICATION AND MODEL SELECTION GUIDE
XYR 5000 Wireless Temperature Transmitters WT530 34-XY-03-02 09/2006 PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The WT530 Temperature Transmitter is part of the XYR 5000 family of wireless
More informationGeneral Specifications
General Specifications Model YTA110 Temperature Transmitter GS 01C0B01-00E [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs
More informationLGP Design. Can be ordered separately see specification 34-ST-03-55
ST 3000 Smart Transmitter Series 900 Gauge Pressure Models STG944 0 to 500 psi 0 to 35 STG94L 0 to 500 psi 0 to 35 STG974 0 to 3000 psi 0 to 210 STG97L 0 to 3000 psi 0 to 210 STG98L 0 to 6000 psi 0 to
More informationAbsolute Pressure Transmitters
AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable
More informationPROGRAMMABLE FIELD TEMPERATURE TRANSMITTER
Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance
More informationAT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model
No. SS2-GTX00G-0600 AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance
More informationRosemount 248 Wireless Temperature Transmitter
Rosemount 248 Wireless Temperature Transmitter Product Data Sheet November 2014 00813-0100-4248, Rev CC Standard temperature transmitter offers a wireless solution for process monitoring Optimize plant
More informationED701 General Industry Pressure Transmitter
ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationGeneral Specifications
General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,
More informationGeneral Specifications
General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationMagnetic Flowmeter Systems
Series 8700 Magnetic Flowmeter Systems THE 8700 SERIES... Model 8712 C/U - Easiest to use local operator interface and works with any manufacturer s flowtubes Model 8712H/8707 High-Signal System - Pulsed
More informationAT9000 Advanced Transmitter Gauge Pressure Transmitters
AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable of
More informationTIY Programmable, Isolated Thermocouple Transmitter combines
April 2016 Description Moore Industries unique digital/analog hybrid the combines smart digital technology with advanced analog operation to deliver superior reliability, accuracy and ease of use. Microprocessor-based,
More informationPressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11
Electronic pressure measurement Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 WIKA data sheet PE 81.27 for further approvals see page
More informationGeneral Specifications
General Specifications GS 01F06F01-01EN Model DY Vortex Flowmeter Model DYA Vortex Flow Converter FOUNDATION Fieldbus Communication Type General FOUNDATION Fieldbus is the digital communication line for
More informationAbsolute Pressure Transmitters
No. SS2-GTX00A-0100 AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent
More informationGeneral Specifications
General Specifications EJA440E Gauge Pressure Transmitter The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam.
More informationURV. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023
ST 3000 Smart Transmitter Series 100 Differential Pressure Models STD110 0 to 10 inh2o 0 to 25 mbar STD120 0 to 400 inh2o 0 to 1,000 mbar STD125 0 to 600 inh2o 0 to 1,500 mbar STD130 0 to 100 psi 0 to
More informationGeneral Specifications
General Specifications EJX110A Differential Pressure Transmitter GS 01C25B01-01E The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to
More informationFKG... 5 PRESSURE TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications
FKG... 5 PRESSURE TRANSMITTER The FCX AIII pressure transmitter accurately measures gauge pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance
More informationAT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model
AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability.
More informationSTT 3000 Smart Temperature Transmitter
STT 3000 Smart Temperature Transmitter Foundation TM Fieldbus Model STT35F Introduction EN0I-6083 April 2009 Specification and Model Selection Guide Honeywell s microprocessor based STT35F Smart Temperature
More informationGeneral Specifications
General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,
More informationGeneral Specifications
General Specifications EJA120E Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJA120E features single crystal silicon resonant sensor and is suitable
More informationOriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple
Data sheet DS/FPD500 EN Rev. E OriMaster FPD500 Compact orifice flowmeter Orifice-based flow metering made simple Integrated DP flow measurement system, pressure tested as an assembly combines primary
More informationRCM DIRECT READING FLOWMETER
RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:
More informationSmart Displacer Level (Interface) Transmitter DLT100 Series
Smart Displacer Level (Interface) Transmitter DLT100 Series Equipped with FISHER FIELDVUE DLC3010 1 Introduction DLT100 series is Smart Displacer Level (Interface) Transmitter equipped with the original
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationSATRON VB Pressure Transmitter
SATRON VB pressure transmitter belongs to the series V transmitters. SATRON VB is userfriendly, through the ball valve mounted transmitter which is used for 04 kpa... 03 MPa ranges. The transmitter communicates
More informationGeneral Specifications
General Specifications EJX120A Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJX120A features single crystal silicon resonant sensor and is suitable
More informationGeneral Specifications
General Specifications EJA130E Differential Pressure Transmitter The high performance differential transmitter EJA130E features single crystal silicon resonant sensor and is suitable to measure liquid,
More informationMODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT
Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer
More informationMicro MV P2DAAA. Custody transfer accuracy Built-in multivariable 3-in-1 transmitter. Daily. Zigbee wireless radio. Extended length battery backup
The Micro MV P2DAAA is a four meter bi-directional field mounted flow computer with a built in Rosemount 205 Multivariable Transmitter (DP, P, and TEMP) which can be used for all liquid and gas applications,
More informationGeneral Specifications
General Specifications Model EJA120A Differential Pressure Transmitter GS 01C21B03-00E The high performance draft range differential transmitter model EJA120A outputs a 4 to 20 ma DC signal corresponding
More informationSITRANS T measuring instruments for temperature
Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.
More information3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.
Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationAccessories for EST4 Series
Accessories for EST4 Series Metallic Capacitance Sensor Capacitance sensor is a passive transducer, which converts the non-electric physical quantity into corresponding capacitance. The capacitance is
More information600T EN Series Pressure Transmitters. Specification sheet. Model 624ES gauge/absolute with direct mount seal for pulp & paper application
Specification sheet 6T EN Series Pressure Transmitters Model 6ES gauge/absolute with direct mount seal for pulp & paper application Base accuracy : ±.7% Reliable inductive sensing system coupled with the
More informationSITRANS P. Transmitters for level. Introduction 1/42. Application
Introduction HK series S series Fig. / transmitters for level, with built-in analog indicator or digital display Application The transmitter with mounting flange measures the level of corrosive and non-corrosive