8900 Multi-Parameter Controller
|
|
- Damian Goodwin
- 5 years ago
- Views:
Transcription
1 F L O W + GF + XX DN XX X XX SE N S OR IN PU TS COM M PO RT / O U T O UT RE LA Y 2 RE LA Y 1 RE LA Y RE LA Y S I G N E T L o o p 1 L o o p 2 D a t a N / C S I G N E T m A I n p u t Cu rre n t Input 1 L o o p 1 + V 7 2 L o o p 1 - D a ta 8 N /C GND 9 L o o p 2 + L o o p 2-6 N /C S L Ou t p u t NC C NC C NO NO RELAY A RELAY B Test A Signet -809 Relay Module COM Test B POWER LISTED E1719 INPUT PASS-THRU + S L - + S L - OUTPUT 2VDC + - Relay A Relay B AC INPUT L N Member of the ProcessPro Family of Instruments Features Measures, ph, ORP, Conductivity,, Level and Temperature Multi-language display 1/ DIN enclosure Up to analog outputs Up to 8 relays Description The Signet takes the concept of modularity to the extreme. Each is field commissioned with the users specified combination of inputs, outputs, and relays using simple-to-install modular boards into the base unit. To assemble a controller, there is a choice of two base units offered with a choice of back-lit LCD or vacuum fluorescent display. Then, continue building with a selection of plug-in modules for either two, four, or six input channels which accepts any of the Signet sensors listed below, and/or other manufacturer s sensors via a to 20mA signal converter (Signet Model 808). To complete your unit, choose a power module with universal AC line voltage or 12 to 2 VDC. If more features are needed, analog output and relay modules are available System Overview Panel Mount Signet Customize the unit to suit any process requirement. Select from a choice of boards Input/ Output Signet digital (S L) or frequency Sensors (sold separately) Use up to 6 inputs with one instrument from a choice of sensors and easily installed. Plus, the will support up to four additional relays via an external relay module. There are other notable features that the offers. For instance, digital input to the enables longer cable runs and simplified wiring with minimal noise interference. Advanced relay logic provides operators an and/or logic to produce high/low alarms. Derived measurements include difference, sum, ratio, percent recovery, percent rejection, and percent passage - and now with BTU. The menu system can be programmed to display in multi-languages including English, German, French, Spanish, Italian, and Portuguese. Power 2 Outputs Relay OUT 2 OUT 1 PO WE R Signet 808, 809 Signal converter/relay Module 12 to 2 VDC or 8 to 26 VAC Power Digital Communication for extended cable lengths and easy wiring Accepts to 20mA output devices when used with 808 signal converter Available with 2, or 6 channels Two BTU calculations Applications RO/DI System Control Media Filtration Pure Water Production Demineralizers Chemical Processing Metal & Plastics Finishing Fume Scrubbers Proportional Chemical Addition Cooling Tower & Boiler Protection Wastewater Treatment Aquatic Animal Life Support Systems Rinse Tank C US E1719 SIGNET X 276X 277X * Signet Fittings (sold separately) See individual sensor data sheets Other manufacturer's sensor with to 20 ma output * Check local Georg Fischer sales office for availability. 22
2 Relay 1 Relay 2 Relay 1 Relay 2 Relay 1 Relay 2 Relay 2 NC C NO NC C NO LISTED E1719 NC C NO NC C NO OUTPUT 2VDC AC INPUT SIG N ET Loop1 PWR Loop2 PWR S L DATA N/C ma Input S L Output N/C 6 Loop2 - Loop2+ N/C Loop1-2 Loop1 + 1 VDC MAX 7 +VDC 8 S L 9 GND B Example 1: input module: Two inputs Signet 20 flow (frequency) and 270 with 27 ph sensors Point-to-point System Overview (continued) There are hundreds of system types that can be set up with the. The examples below illustrate various sensors in different installation schemes. Wiring topology for point-to-point, daisy-chain, multi-drop, or a C1 2.0 µs/cm F2 8. GPM ph 20 combination of these are listed in each example. Digital sensor outputs allow for long cable runs with high noise immunity. See Wiring section for allowable cable lengths. Notes: 1. External relays can be used with any input module and does not consume a sensor input channel (Model 809) 2. Model 808 Signal Converter can be used with any input module. Choosing Multi- Parameter Instrument ph/orp Example 2: input module: Four inputs Signet 20 temp. sensor, 280 with 281 conductivity, and two 20 pressure sensors Daisy-chain Example : input module: Six inputs Signet 20 temp. sensor, 280 with 280 conductivity, 20 pressure, 270 with 27 ph, and 1 and 26 flow (frequency) sensors External Devices: Signet 809 external relay module Combination of Pointto-point and Multi-drop Example : input module: Four inputs Signet 207 flow (frequency) and 270 with 27 ph sensors; Other manufacturers dissolved oxygen and level sensors with to 20 ma output External Devices: Signet 808 signal converter - to 20 ma to digital (S L)) Combination of Pointto-point and Daisychain C1 F µs/cm 8. GPM 1 26 FLOW 20 Temperature C1 2.0 µs/cm F2 8. GPM C1 2.0 µs/cm F2 8. GPM ph Conductivity 809 External Relay RELAY A RELAY B Signet -809 Relay Module COM INPUT PASS-THRU + S L - + S L Signal Converter ma to S L Converter Wiring Options: Point-to-point wiring is direct wiring of individual devices into the controller. This wiring topology is applicable for all inputs. Daisy-chain wiring allows sequential connection from one device to the next by using junction boxes. This wiring topology is applicable for digital (S L) inputs only. POWER Test A Test B Test C Test D RELAY C + - Relay A Relay B Relay C Relay D RELAY D L N 20 Conductivity ph Temperature Generic to 20 ma output sensor (Fully configurable display for any units) Disolved oxygen sensor (example of other brand) 20 Multi-drop wiring allows drops from a single bus cable. Junction boxes can be used for the -way junctions that are formed with this wiring scheme. This wiring topology is applicable for digital (S L) inputs only. 2 Conductivity/ Resistivity Temperature,, Level Other Wiring & Installation Technical Reference Temperature/ Graphs Glossary Part No. of Terms Reference Index
3 Specifications General Configurability: Modular (completely field-commissionable) No. of input channels: 2,, or 6 Compatible sensors: See System Overview Input signal types: Digital (S L): Serial ASCII, TTL level 9600 bps Frequency: 0 to 100 Hz Accuracy: 0.% of reading Measurement types:, ph, ORP, Conductivity/Resistivity,, Temperature, Level, or any device with to 20mA output Derived measurements: Sum, Difference, Ratio, % Recovery, % Reject, % Passage, Power (BTU) No. of relays supported: Available in pairs: 2,, 6 or 8 (8 Dry- Contact and/or Solid State) No. of analog outputs: Available in pairs: 2 or (active and/or passive to 20mA; and/or 0 to /10 VDC) Enclosure and Display Enclosure Rating: NEMA X/IP6 (front face only) Case material: PBT Panel Gasket: Silicone Sponge Window: Self-healing polyurethane-coated polycarbonate Keypad: -buttons, highly tactile and audible Injection-molded silicone rubber seal Display: Alphanumeric 2 x 16 back-lit LCD or Vacuum Fluorescent (VF) versions Update rate: 1 second Accuracy: Sensor dependent VF Brightness: intensity levels LCD Contrast: settings Languages Available: English, French, Spanish, German Italian, and Portuguese Display ranges (see sensor specifications for actual measurement limits): ph: to 1.00 ph ph Temp.: -0 C to 10 C (-0 F to 02 F) ORP: to mv rate: to units per second, minute, hour or day Totalizer: 0.00 to units Conductivity: to μs, ms, PPM & PPB (TDS), kω, MΩ Cond. Temp.: C to 20 C (-18 F to 82 F) Temperature: C to C (-18 F to F) : to 9999 psi, kpa, bar Display ranges (continued) Level: to m, cm, ft, in., % Volume: to m, ft, in, cm, gal, L, kg, lb, % Other ( to 20mA): to user selectable units Environmental Ambient Operating Temperature: Back-lit LCD: -10 C to C (1 F to 11 F) VF Display: -10 C to 0 C (1 F to 122 F) Storage Temp.: -1 C to 80 C ( F to 176 F) Relative Humidity: 0 to 9%, non-condensing Maximum Altitude: 2,000m (6,60 ft.),000m (1,12 ft.); use only DC power supply and, if applicable, solid state relays to maintain UL safety standard up to this altitude. Electrical Power Requirements (AC or DC via Power Modules) Universal AC: 8 to 20 VAC, 0-60 Hz, 2 VA max. DC: 9.9 to 26. VDC unregulated, 7 Watts max. Output Power to Sensors: VDC up to 0mA total Terminal type: Screw-clamp, removable via plug-in modules. Analog Outputs (via I/O Modules and Output Modules) All analog outputs are freely assignable to any channel to 20mA Output: Endpoints are adjustable and reversible: Minimum default:.0 ma; user adjustable from.8 to.0 ma Maximum default: ma; user adjustable from 19.0 to 21.0 ma Test mode: Produces an adjustable to 20mA signal for functional verification of each output circuit Isolation: Up to 8 V AC/DC Error condition: 22.1 ma (default state when output source not configured) Update rate: 100ms Accuracy: ±2μA over entire operating temperature range Dimensions 96mm (.78 in.) 96mm (.78 in.) C1 F2 2.0 µs/cm 8. GPM Relay 1 Relay 2 12mm (.8 in.) 96mm (.78 in.) Optional Rear Cover 6mm (2.21 in.) 92mm (.6 in. 2
4 Specifications (continued) Analog Outputs (Continued) Passive to 20mA Voltage: 12 to 2VDC ±10% Max. Impedance: 12 VDC 18 VDC 2 VDC Active to 20mA Max. Impedance: 60Ω 0 to /10 VDC Output: Output range: 0 to VDC or 0 to 10 VDC, software selectable Endpoints are adjustable and reversible: Minimum default: 0 VDC; user programmable from 0 to 0. VDC Maximum default: VDC; user programmable from. to. VDC, or 9. to 10. VDC Output load: 10kΩ minimum Test mode: Produces an adjustable signal for functional verfication of each output circuit Isolation: Up to 8 V AC/DC Error condition: 0 VDC (default state when output source not configured) Update rate: 100mS Accuracy: ±20mV over entire operating temperature range Resolution: mv Power Supply Rejection: 0. mv/v Relay Modules All relays are freely assignable to any channel. Internal relay modes of operation: Off, Low, High, Window, Pulse, Pulse Width Modulation, USP, Volumetric, Pulse, Totalizer Volume, Advanced, % Rejection External relay modes of operation: Off, Low, High, Window, Pulse Width Modulation, USP, Totalizer Volume, Advanced, % Rejection Hysterisis: User adjustable Time Delay: 0 to 600 seconds Advanced relay: Use AND/OR logic along with relay sources to trigger a relay. High/Low modes available for each of the sources. Solid State Relays: (non-mechanical switches) Normally open/closed operation: Software selectable Maximum pulse rate: 600 pulses/min. (volumetric pulse & PWM modes) 00 pulses/min. (prop. pulse mode) Maximum voltage rating: 0 VDC or 2 VAC p-p Current rating: 0mA DC or 0mA AC RMS On-state impedance: 0Ω or less Off-state leakage: 00nA or less, AC or DC Isolation: Up to 8 V AC/DC Transient protection: Embedded, up to 8 V over-voltage Dry-contact Relays: (mechanical contacts) Type: SPDT Form: C Maximum pulse rate: 600 pulses/min. (volumetric pulse & PWM modes) 00 pulses/min. (prop. pulse mode) Maximum voltage rating: 0 VDC or 20 VAC Current rating: A Shipping Weights: Base unit: Power Module: I/O Module: Output Module: Relay Module: 1.0 kg (2.2 lb.) 0.12 kg (0.2 lb.) 0.12 kg ((0.2 lb.) 0.12 kg (0.2 lb.) 0.12 kg (0.2 lb.) Standards and Approvals CE, UL Manufactured under ISO 9001: 2000 for Quality and ISO 1001:200 for Environmental Management Choosing Multi- Parameter Instrument ph/orp Conductivity/ Resistivity Temperature,, Level Other Wiring & Installation Technical Reference Temperature/ Graphs Glossary Part No. of Terms Reference Index 2
5 POWER Installation of Modules with the base unit -/--VF One base unit is required to build a functional. It is offered with a backlit LCD or a Vacuum Fluorescent Display. Programming the unit is done simply via the push-button keypad. The unit can be tailored to display in English, German, French, Spanish, Italian, and Portuguese. The two line display allows for easy programming, navigation, and viewing of each channel. - --VF X X 1 OUT 2 OUT 1 SENSOR INPUTS COMM PORT/ OUT OUT X RELAY RELAY RELAY 2 RELAY I/O module One I/O module is required to build a functional. I/O modules are offered for 2,, or 6 sensor inputs, with or without 2 milliamp or voltage outputs. Users can select two additional outputs via the output module. 2. Power module One power module is required to build a functional. The power module is offered for universal 110/220 VAC or 12 to 2 VDC (This module can be powered by optional external relays (see ordering information for more details).. Output module Output modules are optional when building an. This module can be used in addition to other outputs that are availble in the I/O modules. Active current and voltage outputs are powered by the. Passive outputs require an outside 12-2 VDC power supply. All outputs are assignable to any input channel. &. Relay modules Relay modules are optional when building an. Relay modes of operation include off, low, high, window, USP, totalizer volume, advanced, pulse, pulse width modulation and volumetric pulse. The advanced relay option for AND/OR logic is used for up to conditions. For instance, a relay will go to high/low if a is true and b or c is false. One or two relay modules can be installed into the. One additional external relay module can also be used at the same time (See optional external relay ordering information.) All relays are assignable to any input channel. Installation of Modules: Modules simply plug in by sliding into the base unit on rails. They are held securely in place by the rear panel. Changes and upgrades can be made in the field at any time. 26
6 Model Ordering Notes: 1) Building a functional unit requires a base unit, I/O module, and power module. 2) Output options are available on I/O modules and additional output modules can be used. The can support up to four outputs. ) Up to two internal relay modules can be used simultaneously; additional external relays can also be used. The can support up to eight relays. ) A maximum total of two frequency sensors can be used with any input card. ) A total of six digital inputs or four digital with two frequency inputs can be used. 6) The boards can be removed or inserted at any time to add /remove inputs, outputs, and relays. 7) The can be reconfigured with new sensor types by simple reprogramming. Please refer to Wiring, Installation, and Accessories sections for more information. Ordering Information To build a functional controller, choose a base unit, power module, and input/output (I/O) module. Additional outputs and relays are available, if needed. Mfr. Part No. Code Description Base units, required; choose one Base unit with back-lit LCD --VF Base unit with Vacuum Fluorescent display I/O (input/output) modules, required; choose one Dual (2) Input (no outputs) Dual (2) Input with Two Passive* Loop Outputs Dual (2) Input with Two Active Loop Outputs Dual (2) Input with Two Voltage Outputs Quad () Input (no outputs) Quad () Input with Two Passive* Loop Outputs Quad () Input with Two Active Loop Outputs Quad () Input with Two Voltage Outputs Six Inputs (no outputs) Six Inputs with Two Passive* Loop Outputs Six Inputs with Two Active Loop Outputs Six Inputs with Two Voltage Outputs Power modules, required; choose one /220 VAC Power Module to 2 VDC Power Module Optional output modules - choose one Two Passive* Current Loop Outputs Two Active Current Loop Outputs Two 0 to and/or 0 to 10 VDC Outputs Optional relay modules - choose one or two Two Dry Contact Relays Two Solid State Relays Optional external relays - choose one** Two dry-contact relays; requires 12 to 2 VDC AC Two dry-contact relays; requires 100 to 20 VAC; supplies power to the 12 to 2 VDC power module Four dry-contact relays; requires 12 to 2 VDC -809-AC * Passive outputs require an outside power source ** See individual product page for the 809 External Relay Modules. Accessories and Replacement Parts Four dry-contact relays; requires 100 to 20 VAC; supplies power to the 12 to 2VDC power host device Mfr. Part No. Code Description Mounting Panel adapter, 1/2 DIN to 1/ DIN Splashproof rear cover / DIN wall mount bracket, 6. in. (use if no rear cover is installed) / DIN wall mount bracket, 9 in. (use if rear cover is installed) Panel adapter, x in. to 1/ DIN Surface mount bracket Power Supplies VDC Power Supply 7. W, 00mA VDC Power Supply 1 W, 600mA VDC Power Supply 0 W, 1. A VDC Power Supply 0 W, 2.1 A VDC Power Supply 100 W,.2 A Miscellaneous RC Filter kit (for relay use), 2 per kit 27 Choosing Multi- Parameter Instrument ph/orp Conductivity/ Resistivity Temperature,, Level Other Wiring & Installation Technical Reference Temperature/ Graphs Glossary Part No. of Terms Reference Index
Signet 8900 Multi-Parameter Controller
Signet 8900 Multi-Parameter Controller Member of the ProcessPro Family of Instruments Features Measures Flow, ph, ORP, Conductivity, Pressure, Level and Temperature Multi-language display ¼ DIN enclosure
More informationSignet 9950 Dual Channel Transmitter
Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,
More informationSignet 9950 Dual Channel Transmitter
Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for Simplified Chinese, English, French, German
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type digital
More informationDial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator
Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Multiple sensor types supported with one instrument Dial-type digital bar graph Modules are field installable and replaceable
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount NEW! Modbus Module supports RS485 Serial Modbus Communications Multiple sensor types supported with
More information+GF+ SIGNET Temperature Transmitter Instructions
GF SIGNET 80- Temperature Transmitter Instructions ENGLISH -80.090- B-/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal
More informationSIGNET 8860 Dual Channel Conductivity/Resistivity Controller
OUTPUT OPTION RELAY 3,4 OPEN COLL 3,4 SHLD ISO GND TEMP 1 SGNL 1 SHLD ISO GND TEMP 2 SGNL 2 - OPEN COLL 4 L N 3-8860.090 C 4/03 English CAUTION! Remove power to unit before wiring input and output connections.
More informationCAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.
SIGNET 8850 Conductivity/Resistivity Transmitter ENGLISH 8850.090 C/0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.
More informationSignet Flow Transmitter
Signet 80- Flow *-80.090-* English -80.090- Rev. L 0/ English WARNING! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.
More informationph/orp Transmitter SIGNET
SIGNET 8750- ph/orp Transmitter -8750.090- D-4/0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.
More informationContents 1. Installation
ENGLISH 880.090 D0/0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation. Specifications. Electrical
More informationConductivity/Resistivity Transmitter
88502 Conductivity/Resistivity Transmitter English *38850.0902* 38850.0902 Rev.H 8/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to
More informationSignet 2750 DryLoc ph/orp Sensor Electronics
Signet 2750 DryLoc ph/ Sensor Electronics Features In-line integral mount and submersible installation versions Automatic temperature compensation Auto configuration for ph or operation In-line 2750 Submersible
More informationSignet Conductivity/Resistivity Transmitter
Signet 88503 Conductivity/Resistivity Transmitter English *38850.0903* 38850.0903 Rev. G 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully
More informationSignet Conductivity/Resistivity Transmitter
Signet 8803 Conductivity/Resistivity Transmitter English *3880.0903* 3880.0903 Rev. K 11/1 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully
More informationSignet ph/orp Transmitter * *
Signet 8750-3 ph/orp *3-8750.090-3* 3-8750.090-3 Rev. G 0/06 English English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.
More informationSignet 2751 DryLoc ph/orp Smart Sensor Electronics
Signet 2751 DryLoc ph/ Smart Sensor Electronics Features Probe health monitoring, glass impedance and broken glass detection Memory chip interface that allows for transferable calibration, runtime data,
More informationAnalytical Transmitters
Analytical Transmitters THORNTON Leading Pure Water Analytics M300 Transmitters Conductivity / Resistivity ph / ORP Dissolved Oxygen Dissolved Ozone Flow / Total Flow M300 Transmitters for Comprehensive
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Protected Bulb Patented reference design for exceptional performance* Mounts in Signet standard fittings from
More informationSignet ph/orp Electrodes General Purpose
Signet 2724-2726 ph/orp Electrodes General Purpose Compatible with ALL Signet ph/orp instruments and SmartPro transmitters Features Patented reference design for exceptional performance and prolonged life
More informationCX105 Conductivity/Resistivity Transmitter
CX105 Conductivity/Resistivity Transmitter User Manual REV A.15 Sensorex Corporation, USA 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. www.sensorex.com IMPORTANT SAFETY INFORMATION Please read and
More informationModel Sono-Trak Transit Time
Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationSignet 9900 Transmitter
Signet 9900 Transmitter *3-9900.090* 3-9900.090 Rev. C 08/13 Operating Instructions English Quick Start Look for the Quick Start icon to quickly set up your new 9900. Your new Signet 9900 Transmitter needs
More informationEconomical Digital Indicators For Process and Electrical Measurement
Economical Digital Indicators For Process and Electrical Measurement DP18 Series Panel Punches Available DP18-P5, 4 to 20 ma input. DP18-EC, thermocouple input visit omega.com/thermocouple for thermocouples.
More informationSignet 9900 Transmitter
English Signet 9900 Transmitter *3-9900.090* 3-9900.090 Rev. E 06/14 Operating Instructions Quick Start Look for the Quick Start icon to quickly set up your new 9900. Your new Signet 9900 Transmitter needs
More informationSingle and Dual Input Analyzers for Low-level Conductivity
Data Sheet SS/AX4CO Issue 11 Single and Dual Input Analyzers for Low-level Conductivity AX410, AX411, AX416, AX450 and AX455 Cost effective select one or two conductivity inputs or combine conductivity
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationModel 332 Temperature Controller
94 Instruments Model 332 Temperature Controller Features Operates down to 500 mk with appropriate NTC RTD sensors Model 332 Temperature Controller Two sensor inputs Supports diode, RTD, and thermocouple
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationAdvanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched
EXL6 OCS Datasheet for HE- EXL1E0, HE- EXL1E2, HE- EXL1E3, HE- EXL1E4, HE- EXL1E5, HE- EXL1E6 HEXT371C100, HEXT371C112, HEXT371C113, HEXT371C114, HEXT371C115, HEXT371C116 1. Specifications Required Power
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationUltrasonic level transmitter, non-contact
Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationPROCESS & TEMPERATURE CONTROLLERS
PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs
More informationSignet 9900 Transmitter
Signet 9900 Transmitter *3-9900.090* 3-9900.090 Rev. A2 08/11 Operating Instructions English Quick Start Your new Signet 9900 Transmitter needs to be calibrated and the sensor needs to be initialized prior
More informationFLOMID FX Electromagnetic Flowmeter
FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics
More informationDP2000 ORDERING GUIDE To Order MODEL NO.
1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers for low level conductivity
ABB MEASUREMENT & ANALYTICS DATA SHEET AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers for low level conductivity 2 A X410, A X411, A X416, A X450 AND A X4 55 CONDU C TIV IT Y ANALY
More informationEXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X
KOBO-pH Transmitter for ph-value and ORP Model APM-X measuring monitoring analysing EXPERT-LINE Measuring range: ph value: 0 to 14 ORP: -1500 to +1500 mv (0-100%) For general-purpose use with: Analogue
More informationAnalyze IT Single and Dual Input Analyzers for ph/redox (ORP)
Data Sheet Analyze IT Single and Dual Input Analyzers for ph/redox (ORP) Cost effective select from two input ph/redox (ORP) or combined ph/redox (ORP) and conductivity in one analyzer High functionality
More informationAnalog outputs (option) Output 1 + 2: 0(4) 20 ma or 0 10 V
Page / JUMO AQUIS 500 CR Transmitter/Controller for conductivity, TDS, resistivity and temperature Compliant with USP Brief description The instrument is used for the conductive measurement/control
More informationModel FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter
Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------
More informationJUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature
Data Sheet 20272 Page /7 JUMO ecotrans Lf 0 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature Type 20272 Housing for DIN rail mounting (5 x 7.5 mm to DIN EN
More informationConductivity Analyzer
Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures
More informationDissolvedOxygenMonitor
Call 800.959.0299 to speak with a sales representative or visit us on the web at www.analyticaltechnology.com DissolvedOxygenMonitor Model Q46D Dissolved Oxygen Monitoring is critical to stable operation
More informationSignet 9950 Dual Channel Transmitter
English Signet 9950 Dual Channel Transmitter *3-9950.090* 3-9950.090 Rev. 7 02/19 Operating Instructions (see pg. 11) Description 3-9950-1, -2 NOTE: Prior to installation, Check www.gfsignet.com for software
More informationZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement Modbus ASCII /RTU Compatible Wide Operating Temperature Active Repeater Functionality 10 to 48 VDC & 24 VAC Input Power Zlinx Wireless Modbus I/O - flexible enough
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationNo mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.
Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital
More informationHigh Performance Process & Temperature Controllers
C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal
More informationDissolved Oxygen Measurement liquisys M COM 223 F / 253 F
Technical Information TI 246C/24/ae Dissolved Oxygen Measurement liquisys M COM 223 F / 253 F Oxygen Controller Benefits at a glance Liquisys M COM 223 F Liquisys M COM 253 F Due to the modularity of its
More informationAgilent Technologies 3000 Series Oscilloscopes
Agilent Technologies 3000 Series Oscilloscopes Data Sheet Full-featured oscilloscopes for the smallest budgets Features: 60 to 200 MHz bandwidths 1 GSa/s maximum sample rate Large 15-cm (5.7-in) color
More informationRI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA
More informationMODEL: KS. Plug-in Signal Conditioners K-UNIT
Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided
More informationUniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30
UniStream Built-in Technical Specifications US5-B5-RA28, US5-B10-RA28 US5-B5-TA30, US5-B10-TA30 US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30 Unitronics UniStream Built-in series are PLC+HMI All-in-One
More information* * Signet 2610 Process Optical Dissolved Oxygen Sensor. Operator's Manual. Introduction. English. System Description.
Signet 2610 Process Optical Dissolved Oxygen Sensor *32610.090* 32610.090 Rev. C 08/13 English Operator's Manual Introduction System Description Your new RDO Pro is a rugged, reliable sensor designed to
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationEffective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937
Effective: June, 2000 LevelPRO Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937 The information contained in this manual was accurate at the time of release. Specifications
More informationGE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor
clear mode enter clear mode enter GE Sensing Introduction The GE Telaire Vaporstat 900 sensor measures in applications in the range of 0 to 0 F dew point. The sensor package is designed for wall mounting.
More informationSIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier
Model 7265 DSP Lock-in Amplifier FEATURES 0.001 Hz to 250 khz operation Voltage and current mode inputs Direct digital demodulation without down-conversion 10 µs to 100 ks output time constants Quartz
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationAX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)
Data sheet DS/AX4PH EN Rev. K AX460, AX466 and AX416 More processing power, higher performance Cost effective select one or two ph/redox (ORP) inputs or combine ph/ Redox (ORP) and conductivity in one
More informationPortable Multi-Channel Recorder Model DAS240-BAT
Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes
More informationMODEL: JB2. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT ANALOG BACK STATION Functions & Features Enables manual loading providing hold/increase/ decrease signals to a device controlled by PID controller When the PID controller
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationWATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL
MicroChem Water Analysis System The MicroChem is a versatile multi-parameter instrument capable of being configured as a transmitter or PID controller. Specifically designed for drinking and wastewater
More informationCALYS channels High accuracy calibrator
CALYS 150 2 channels High accuracy calibrator Simultaneous IN and OUT 2 measurement channels Protected for on-site use Easy-Connect system Data acquisition HART protocol transmitter automatic calibration
More informationExcellent low-cost Process & Temperature Controllers
C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationUSB-TEMP and TC Series USB-Based Temperature Measurement Devices
USB-Based Temperature Measurement Devices Features Temperature and voltage measurement USB devices Thermocouple, RTD, thermistor, or semiconductor sensor measurements Eight analog inputs Up to ±10 V inputs*
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)
ABB MEASUREMENT & ANALYTICS DATA SHEET AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP) 2 A X460, A X466 AN D A X416 P H / RE DOX (ORP) ANALY ZE RS DS/A X4PH-E N RE V. M Measurement
More informationSILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets
SILVER SERIES Low Cost, Single-Wavelength (1λ) Industrial Infrared Thermometers SSDS2013 Reliable compact industrial infrared thermometers for Temperatures below 3632 F/2000 C Non-reflective target materials
More informationConductivity Transmitter
Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationAdvanced, accurate and intelligent monitoring for your transformer
QUALITROL 505 ITM Intelligent transformer monitor Advanced, accurate and intelligent monitoring for your transformer The power to know your transformer health immediately with TransLife Advanced thermal
More informationMULTIFUNCTION GRAPHICAL UNIT MGU 800
MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationElectro Controls. Input-Output Modules WattsIndustries.co.uk
Electro Controls Input-Output Modules - 2017 WattsIndustries.co.uk Input-Output Modules Section 08 B.M.S INPUT - OUTPUT MODULES SINGLE AND ADJUSTABLE RELAY ESRM.. Volt free contacts DIN RAIL mounted relay
More informationLST400 Ultrasonic level / open channel flow transmitter
Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting
More informationINTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:
Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:
More information- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION
ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS
More informationFuzzy Temperature Controllers E5AF
Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate
More informationHigh-precision process calibrator Model CED7000
Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry
More informationAdditel 875 Series Dry Well Calibrators
Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect
More informationDigital flow ELEMENT transmitter for continuous flow measurement
Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single
More informationcontrol & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS
S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip
More information7SD/7SH/7SM Temperature Controllers
7SD/7SH/7SM Temperature ADVANTAGE EZ Series 7SD, 7SH, 7SM 1/16 DIN Temperature 3Digit LED Display Thermocouple and RTD Input Autotuning NEMA 4X Field onfigurable 100 to 40 Vac Switching Power Supply Programmable
More informationDUAL-INPUT INTELLIGENT ANALYZER
Product Data Sheet PDS 71-1056/rev.D January 2008 Model 1056 DUAL-INPUT INTELLIGENT ANALYZER MULTI-PARAMETER INSTRUMENT single or dual input. Choose from any combination of ph/orp/ise, Resistivity/Conductivity,
More informationIndustrial Modbus I/O Modules
Industrial Modbus I/O Modules Modbus I/O Modules Introduction & Features Digital Input / Output Modules Analog Input / Output Modules Modbus I/O Modules The Best Choice For Your SCADA Applications Introduction
More informationADAM 4000/4100 Series
ADAM 4000/4100 Series Common Dimensions Communication RS-485 (2-wire) to host Speeds: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (ADAM-4080, ADAM-4080D only support up to 38400 bps) Max. communication
More informationDigital flow ELEMENT transmitter for continuous flow measurement
ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor
More informationCorporate Profile. needs and product demands. CON 08X /03 Rev 0
Corporate Profile A leader in the field of electrochemical instrumentation, Eutech Instruments is a dynamic company rapidly positioning itself globally as a leading manufacturer of electrochemical instrumentation
More informationOperation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.
Electronics & Software Type 5080A... Multichannel Laboratory This universal laboratory charge amplifier can be used for force and torque measurements with piezoelectric dynamometers or force plates. Piezoelectric
More informationTechnical Information RMS621
TI00092R/09/EN/14.16 71355039 Products Solutions Services Technical Information RMS621 Energy manager Steam and Heat Computer for Industrial Energy Calculation of Steam and Water Application Energy management
More information