IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 1, FEBRUARY

Size: px
Start display at page:

Download "IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 1, FEBRUARY"

Transcription

1 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 1, FEBRUARY Optimization of Dual Layer Phoswich Detector Consisting of LSO and LuYAP for Small Animal PET Yong Hyun Chung, Yong Choi, Member, IEEE, Gyuseong Cho, Member, IEEE, Yearn Seong Choe, Kyung-Han Lee, and Byung-Tae Kim Abstract Phoswich detectors for small animal PET have been developed to measure the depth of interaction and to improve resolution performances. The aim of this study was to perform simulations to design the optimum lengths of crystals composing a dual layer phoswich detector. A simulation tool, the Geant4 Application for Tomographic Emission (GATE), was used and validated against a commercially available small animal PET using a dual layer phoswich detector. The newly designed small PET system employed cerium doped lutetium oxyorthosilicate (LSO) cerium doped lutetium-yttrium aluminum perovskite (LuYAP) phoswich detector modules, which consisted of 8 8 arrays of dual layer crystals, with a 2 2 mm sensitive area, coupled to a Hamamatsu R M64 position sensitive photomultiplier tube (PSPMT). The sensitivities and variations of the radial resolutions were simulated by varying the length of the LSO front layer from 0 to 10 mm, while the total length (LSO+LuYAP) was fixed to 20 mm for 10 and 19 cm diameter ring scanners. The results support the validity of the simulation tool. The radial resolution uniformity was markedly improved using the depth of interaction (DOI) information, and the optimal lengths of the crystal layers for minimizing the variation of the radial resolutions also existed. In the 10 cm ring scanner configuration, the radial resolution was kept below 3.4 mm, over 8 cm field of view (FOV), while the sensitivity was higher than 7.4% for the LSO 5 mm : LuYAP 15 mm phoswich detector. The resolution variations were minimized to less than 3.6 mm, over 16 cm FOV, using a LSO 6 mm : LuYAP 14 mm phoswich detector for the 19 cm ring scanner. In this study, the optimal length of the dual layer phoswich detector was derived to achieve a high and uniform radial resolution. Index Terms Depth-of-interaction, phoswich detector, small animal PET. I. INTRODUCTION AS AN EFFECTIVE imaging probe in the area of animal models of human disease, gene expression and therapy, and drug discovery and development, small animal PET imaging is being used increasingly [1] [3]. An ideal small animal PET should have a high sensitivity and uniform resolution Manuscript received March 4, 2004; revised May 27, This work was supported by the Korea Institute of Science and Technology Evaluation and Planning (KISTEP) and the Ministry of Science and Technology, through the National Nuclear Technology Program, and by a grant from the Korea Health 21 R&D Project (02-PJ3-PG6-EV ), Ministry of Health and Welfare, Republic of Korea. Y. H. Chung, Y. Choi, Y. S. Choe, K.-H. Lee, and B.-T. Kim are with Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University, School of Medicine, Seoul, , Korea ( dryong.choi@samsung.com). Y. H. Chung and G. Cho are with Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Taejon , Korea. Digital Object Identifier /TNS across the field of view to achieve high image quality. However, the combination of a long narrow pixellated crystal array and the small ring diameter of small animal PET leads to degradation of the spatial resolution of the imaging object located off-center. The annihilation event that originates off-center might be registered to an inaccurate line of response (LOR) and blur image resolution, because obliquely incident gamma rays in a PET might penetrate several pixellated crystals before interacting in a crystal, presenting only the information of the crystal of interaction. This degradation of resolution can be improved by determining DOI in the crystal, and by taking into account the information when sorting the coincident events [4]. A number of DOI determination schemes have been proposed. These include the use of a phoswich detector constructed of several different scintillators with different decay times [5] [7], stacking scintilltors with different concentrations of doping material [8] and coupling photosensitive detectors, such as PSPMT, photodiodes and avalanche photodiodes, to opposite ends of the crystals [9], [10]. Other approaches have employed controlling light sharing between crystals using various surface treatments [11] and a multistage rectangular block of crystals segmented along the depth to extract DOI information from the light distribution property in crystals [12]. Among those DOI identification schemes, the dual layer phoswich detector has been widely investigated by many research groups, due to its practicability and effectiveness of extracting DOI information. In a commercially available small animal PET scanner, ATLAS (Advanced Technology Laboratory Animal Scanner) [13], which was developed at the National Institute of Health (NIH), Bethesda, MD, has a DOI measurement capability by employing this technique. However, the effects of each crystal length composing the dual layer phoswich detector on the DOI measurement capabilities and image qualities have not been fully characterized. In order to minimize the DOI effect, the length of each layer of the phoswich detector should be optimized. The goal of this work was to perform simulation studies to characterize and optimize the lengths of two different crystal layers of a phoswich detector for a small PET to achieve a high and uniform resolution. For this purpose, a Monte Carlo simulation tool, GATE [14], a simulation platform developed for PET and SPECT, was used. A validation study of the simulation method for the dual layer crystal performances was performed against ATLAS [13]. The radial resolution and sensitivity of a PET scanner being designed in our laboratory were simulated for the combined LSO front layer and LuYAP back layer phoswich detector /$ IEEE

2 218 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 1, FEBRUARY 2005 II. MATERIALS AND METHODS A. Monte Carlo Simulation Tool, GATE The Monte Carlo simulation tool used in this study was GATE, an object oriented simulation platform for a versatile solution dedicated to PET and SPECT [14]. GATE was built on top of the well-proved simulation tool GEANT4 [15], and a user can model various aspects of a PET experiment to simulate most of the phenomena encountered in PET using a scripting language. One may specify the ring-type PET geometry, and any number of radioactive sources with different properties. The scanner geometry, such as the number of rings, detector modules arranged in those rings, number of crystals in a detector module and lengths and materials composing the crystal layers can be parameterized. Movements, such as rotations of the scanner and translations of the phantom as a function of time can be scripted. Radioisotope decays can be specified, and the decay time and interactions with scanner materials (photoelectric effect, Compton scattering, Rayleigh scattering and gamma ray conversion) are computed from the activity, the radioisotope half-lives and the properties of the materials. Single and coincident detections of gamma rays by the crystals can be stored on an event-by-event basis into multiple output files with different file formats. B. Validation of Monte Carlo Simulation Tool With ATLAS A small animal PET scanner, ATLAS, using a dual layer phoswich detector, having DOI measurement capability for imaging animals up to 6 cm in diameter [13], was chosen for validation purposes. ATLAS is based on the cerium doped lutetium gadolinium oxyorthosilicate (LGSO) cerium doped gadolinium oxyorthosilicate (GSO) phoswich detector module, which consisted of a 9 9 array of mm phoswich elements, with a 2.25 mm pitch. Each element consisted of a 7 mm long LGSO front layer and an 8 mm long GSO back layer. The end of the GSO was optically coupled to a Hamamatsu R7600-C8 PSPMT, with 18 modules arranged around a ring with an 11.8 cm diameter. The layer of interaction was identified by measuring the decay time difference between the LGSO (40 ns) and GSO (60 ns) of each event. The variation in the resolution across the field of view and the sensitivity of the ATLAS were simulated, and compared to the measured data of Seidel et al The spatial resolutions of the ATLAS were simulated by moving a 0.5 mm diameter point source, with 4 mm increments in the radial direction, from 1.3 out to 31.3 mm from the scanner center. Images of the source at each position were reconstructed using 2 D filtered backprojection and a Ramp filter. The radial profiles of the point source images were fitted to a Gaussian function to measure the spatial resolution. The simulated sensitivity, the fraction of annihilation yielding detected coincidence events, was measured using a point source located at the center of the scanner for low energy thresholds of 100 and 250 kev. C. Design Parameters of Our Small PET Two small PET systems were designed, one with a 10 cm ring diameter for rodents, and the other with a 19 cm ring diameter for primates. These two designs were simulated to characterize Fig. 1. Geometrical illustration of the spatial broadening for various front and back layer lengths of a phoswich detector. Thick arrow: the direction and mean free path of a 511 kev photon obliquely incident on the LSO-LuYAP crystals. Dashed line: the possible LORs from the front layer, dotted line: the possible LORs from the back layer, of the phoswich detector. Fig. 2. Simulated and measured radial resolutions obtained by stepping a point source at 4 mm increments in the radial direction from the center to the 31.3 mm radial offset for the ATLAS scanner. Fig. 3. Simulated sensitivities of 10 and 19 cm diameter ring scanners as a function of the front layer length. the effects of the phoswich detector lengths on correcting parallax errors as a function of the ring diameters.

3 CHUNG et al.: OPTIMIZATION OF DUAL LAYER PHOSWICH DETECTOR CONSISTING OF LSO AND LuYAP FOR SMALL ANIMAL PET 219 Fig. 4. Reconstructed images of the point source obtained by moving a source from the center to the radial offset of the scanner s FOV, at 10 mm intervals, and their profiles for the 10 cm scanner. (a) 20 mm LSO single layer detector, without DOI information, (b) LSO 5 mm : LuYAP 15 mm phoswich detector, with DOI information. The simulated small PET system employed phoswich detector modules arranged in a ring, comprising of a LSO front layer and a LuYAP back layer with DOI capability. LSO was chosen for the detector due to its high stopping power, high light output and fast decay time [16]. LuYAP has almost the same density as LSO, while the decay time is about 2 times faster [17]. A detector module, consisting of 8 8 arrays of dual layer crystals, with a 2 2 mm sensitive area (2.3 mm pitch), was coupled to a 64 channel Hamamatsu R M64 PSPMT. Two small PET systems, with diameters of 10 and 19 cm, had 4 rings with 16 and 32 modules per ring, respectively. The total crystal length (LSO LuYAP) was fixed at 20 mm to allow sufficient sensitivity, with the lengths of the front and back layers varied to evaluate the effects of the DOI measurement for the improvement of the parallax errors. D. Simulation for Characterization of Phoswich Detector Lengths Fig. 1 illustrates the geometrical representation of the spatial broadening for various phoswich detector layer lengths. The thick arrows represent the direction and mean free path (1.15 cm at 511 kev for LSO, [18]) of 511 kev photons obliquely incident on the LSO-LuYAP crystals. The dashed and dotted lines illustrate the possible LORs from the front and back layers of the phoswich detector, respectively. Off-center events incident on the single layer crystals resulted in blurred images, due to inaccurate LORs, as shown in Fig. 1(a). As the front layer length in dual layer phoswich detector was increased, the spatial broadening of the LORs decreased and reached the minimum [Fig. 1(b) (d)]. Then, the spatial broadening of the LORs were further increased [Fig. 1(e) (f)]. Therefore, optimum lengths of the dual layers existed to minimize image blurring and preserve the spatial resolution. The effects of each crystal length, consisting of the dual layer phoswich detector, on a blurred image were investigated by the Monte Carlo simulation. The length of the front layer was varied from 0 to 10 mm, with 1 mm intervals, while the total length (LSO LuYAP) was fixed at 20 mm. For each combination of front and back layer lengths of the phoswich detector, the radial resolutions and sensitivities of the proposed scanners were estimated. A 0.1 mm diameter point source was placed at the center of the field of view to measure the sensitivity, which was defined as a fraction of the annihilations yielding valid coincidences. The energy window was set between 250 and 650 kev. To calculate the spatial resolutions of PET systems consisting of various phoswich detectors, a 0.1 mm diameter point source was positioned out to 40 and to 80 mm, in 10 mm steps, starting at the center of the 10 and 19 cm diameter scanners, respectively. The simulated events were stored in a list mode format (LMF) that recorded the interacting positions, deposited energies and time stamps of each event. After images of the source at each position had been reconstructed, using 2 D filtered backprojection with a ramp filter, the full-width at half-maximums (FWHMs) of the radial profiles were estimated by Gaussian fitting.

4 220 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 1, FEBRUARY 2005 Fig. 5. Simulated radial resolution obtained by moving a source from the center to the radial offset of the scanner s FOV, as a function of the source position (a) for the 10 cm diameter ring scanner with a LSO front layer (F) and a LuYAP back layer (B), and (b) for the 19 cm diameter ring scanner. III. RESULTS A. Validation of Monte Carlo Simulation Tool With ATLAS The simulated sensitivities were 2.8% and 2.0%, with lower level discriminator (LLD) values of 100 and 250 kev, respectively. The measured sensitivities were 2.7% and 1.8%, with 100 and 250 kev LLD thresholds, respectively. The simulated and measured sensitivities closely agreed with the 4% discrepancies. Fig. 2 shows the simulated and measured radial resolutions obtained by stepping a point source at 4 mm increments in the radial direction from the center to a 31.3 mm radial offset for the ATLAS scanner. The FWHMs obtained by the simulations and measurements ranged from 2.0 mm to 2.5 mm and 1.9 mm to 2.6 mm, with mean values of 2.2 mm and 2.2 mm, respectively. The discrepancies between the simulated and measured resolutions were under 5% over the entire FOV of the ATLAS. B. Optimization of Phoswich Detector Lengths Fig. 3 shows the simulated sensitivities of the 10 and 19 cm diameter ring scanners as a function of the front layer length. Fig. 6. Simulated radial resolution as a function of front layer length (a) for the 10 cm diameter ring scanner and (b) for the 19 cm diameter ring scanner. These curves were obtained with a 250 to 650 kev energy window. The simulated sensitivities increased from 7.1 to 8.6% and from 5.4 to 6.5%, proportional to the front layer (LSO) length, for the 10 and 19 cm diameter scanners, respectively. The effects of the crystal layer lengths of the phoswich detector on the DOI measurements and the image qualities were demonstrated as a function of the front layer length of the phoswich detector. Fig. 4 illustrates reconstructed images, and the profiles of their point sources obtained by moving the source from the center to the radial offset of the scanner sfov, at 10 mm intervals for the 10 cm diameter scanner with a LSO single layer of 20 mm and with a LSO 5 mm : LuYAP 15 mm phoswich detector. This figure demonstrates the effects of the DOI measurements on correcting the parallax error and the marked, especially at off-center, improvement in resolution. The variations in the radial resolution for each combination of phoswich detector lengths, as a function of the source position for two different scanner ring diameters, are shown in Fig. 5. Fig. 6 shows the variations in the radial resolution as a function of the front layer length. As described in Fig. 1, the radial resolution initially decreased, but then increased, after reaching the

5 CHUNG et al.: OPTIMIZATION OF DUAL LAYER PHOSWICH DETECTOR CONSISTING OF LSO AND LuYAP FOR SMALL ANIMAL PET 221 minimum value, as the length of front layer increased. As illustrated in Figs. 5 and 6, the radial resolutions at 40 mm off-center were 5.6, 3.4, 4.1, and 7.9 mm when the ring diameter was 10 cm and the front layer lengths were 2, 5, 10, and 20 mm, respectively. For the 19 cm diameter scanner, the radial resolutions at 80 mm off-center were 6.2, 3.6, 4.6, and 9.6 mm when the front layer lengths were 2, 6, 10, and 20 mm, respectively. The minimum radial resolution was achieved when the front layer lengths were 5 and 6 mm for the 10 and 19 cm diameter scanners, respectively. IV. DISCUSSION AND CONCLUSION The simulated sensitivity and radial resolution variation of the ATLAS scanner were in good agreement with those measured. These results support the validity of the Monte Carlo simulation tool, GATE, for the sensitivity and resolution estimation of the small animal PET using a phoswich detector. The radial resolution uniformity was considerably improved using the DOI information. When a dual layer phoswich crystal is employed, optimum lengths of layers exist, which can minimize the radial resolution variations, as shown in Fig. 6. Fig. 6 demonstrates that better spatial resolution can be obtained when the front layer is shorter than the back layer. In the 10 cm diameter ring type PET scanner configuration, radial resolutions less than 4 mm were provided over an 8 cm FOV when the length of the front layer ranged from 4 to 8 mm, and the best resolution uniformity was achieved when the front layer length of the phoswich detector was 5 mm. Using the LSO 5 mm : LuYAP 15 mm phoswich detector, the radial resolution was markedly improved, from 8.0 to 3.4 mm, at a 40 mm offcenter, compared to the 20 mm LSO single layer detector. When the ring diameter was 19 cm, the minimum variation of the radial resolution was achieved with a 6 mm front layer length for the phoswich detector, and the radial resolutions were kept below 3.0 and 3.6 mm over 12 and 16 cm FOVs, respectively. The sensitivities increased proportionally to the front layer length, LSO has a higher stopping power than LuYAP, as shown in Fig. 3. Since the optimum front layer length was relatively short compared to that of the back layer in the proposed phoswich detector, the sensitivity of the proposed system was low. It may be possible to improve the sensitivity without decreasing the resolution by changing the sequence of crystals in phoswich detector and by using a longer LSO crystal. In order to increase the sensitivity, an optimization study for a phoswich detector composed of LuYAP front and LSO back layers is in progress. However, the light output of LuYAP is about 3 times less than that of LSO. An experimental approach to evaluate the possibility of measuring the light outputs from a LuYAP front layer is required for the application of the crystal identification methods for distinguishing the LSO and LuYAP layers, such as decay time measuring and light pulse shape discrimination schemes [19]. In this study, the effects of the crystal lengths in a dual layer phoswich detector on the DOI capability were characterized, with the optimal crystal lengths derived for small animal PET, with 10 and 19 cm diameters, to achieve high and uniform radial resolutions. REFERENCES [1] R. S. Balaban and V. A. Hampshire, Challenges in small animal noninvasive imaging, ILAR J., vol. 42, pp , [2] A. F. Chatziioannou, S. R. Cherry, Y. Shao, R. W. Silverman, K. Meadors, T. H. Farquhar, M. Pedarsani, and M. E. Phelps, Performance evaluation of micropet: A high-resolution Lutetium oxyorthosilicate PET scanner for animal imaging, J. Nucl. Med., pp , [3] S. R. Cherry and S. S. Gambhir, Use of positron emission tomography in animal research, ILAR Journal, vol. 42, pp , [4] P. Bartzakos and C. L. Thompson, A depth-encoded PET detector, IEEE Trans. Nucl. Sci., vol. 38, pp , [5] J. Seidel, J. J. Vaquero, S. Siegel, W. R. Gandler, and M. V. Green, Depth identification accuracy of a three layer phoswich PET detector module, IEEE Trans. Nucl. Sci., vol. 46, pp , [6] M. Dahlbom, L. R. MacDonald, L. Eriksson, M. Paulus, M. Andreaco, M. E. Casey, and C. Moyers, Performance of a YSO/LSO phoswich detector for use in a PET/SPECT system, IEEE Trans. Nucl. Sci., vol. 44, pp , [7] U. Heinrichs, U. Pietrzyk, and K. Ziomons, Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3, IEEE MIC Rec., vol. M3-26, [8] S. Yamamoto and H. Ishibashi, A GSO depth of interaction detector for PET, IEEE Trans. Nucl. Sci., vol. 45, pp , [9] W. W. Moses, S. E. Derenzo, C. L. Melcher, and R. A. Manente, A room temperature LSO/Pin photodiode PET detector module that measures depth of interaction, IEEE Trans. Nucl. Sci., vol. 42, pp , [10] Y. Shao, R. W. Silverman, R. Farrell, L. Cirignano, R. Grazioso, K. S. Shah, G. Vissel, M. Clajus, T. O. Tumer, and S. R. Cherry, Design studies of a high resolution PET detector using APD arrays, IEEE Trans. Nucl. Sci., vol. 47, pp , [11] C. Moisan, M. S. Andreaco, J. G. Rogers, S. Paquet, and D. Vozza, Segmented LSO crystals for depth of interaction encoding in PET, IEEE Trans. Nucl. Sci., vol. 45, pp , [12] H. Murayama, H. Ishibashi, H. Uchida, T. Omura, and T. Yamashita, Depth encoding multicrystal detectors for PET, IEEE Trans. Nucl. Sci., vol. 45, pp , [13] J. Seidel, J. J. Vaquero, and M. V. Green, Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: Comparison to simulated LSO scanner without depth-of-interaction capability, IEEE MIC Rec., vol. M9A-5, [14] G. Santin, D. Strul, D. Lazaro, L. Simon, M. Krieguer, M. M. Vieira, V. Breton, and C. Morel, GATE: A Geant4-based simulation platform for PET and SPECT integrating movement and time management, IEEE Trans. Nucl. Sci., vol. 50, pp , [15] GEANT4: A Simulation Toolkit,, SLAC Report SLAC-PUB-9350, Aug GEANT4 Collaboration. [16] C. L. Melcher and J. S. Schweitzer, Cerium-doped lutetium oxyorthosilicate: A fast, efficient new scintillator, IEEE Trans. Nucl. Sci., vol. 39, pp , [17] M. Moszynski, D. Wolski, and T. Ludziejewski, Properties of the new LuAP:Ce scintillator, Nucl. Instrum. Methods, vol. A(385), pp , [18] H. Zaidi, Relevance of accurate Monte Carlo modeling in nuclear medical imaging, Med. Phys., vol. 26, pp , [19] M. Streun, G. Brandenburg, H. Larue, H. Saleh, E. Zimmermann, K. Ziemons, and H. Halling, Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET, IEEE Trans. Nucl. Sci., vol. 50, pp , 2003.

976 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 57, NO. 3, JUNE /$ IEEE

976 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 57, NO. 3, JUNE /$ IEEE 976 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 57, NO. 3, JUNE 2010 A Four-Layer DOI Detector With a Relative Offset for Use in an Animal PET System Mikiko Ito, Jae Sung Lee, Sun Il Kwon, Geon Song Lee,

More information

Conceptual Study of Brain Dedicated PET Improving Sensitivity

Conceptual Study of Brain Dedicated PET Improving Sensitivity Original Article PROGRESS in MEDICAL PHYSICS 27(4), Dec. 2016 https://doi.org/10.14316/pmp.2016.27.4.236 pissn 2508-4445, eissn 2508-4453 Conceptual Study of Brain Dedicated PET Improving Sensitivity Han-Back

More information

Performance characterization of a novel thin position-sensitive avalanche photodiode-based detector for high resolution PET

Performance characterization of a novel thin position-sensitive avalanche photodiode-based detector for high resolution PET 2005 IEEE Nuclear Science Symposium Conference Record M11-126 Performance characterization of a novel thin position-sensitive avalanche photodiode-based detector for high resolution PET Jin Zhang, Member,

More information

Performance measurements of a depth-encoding PET detector module based on positionsensitive

Performance measurements of a depth-encoding PET detector module based on positionsensitive Home Search Collections Journals About Contact us My IOPscience Performance measurements of a depth-encoding PET detector module based on positionsensitive avalanche photodiode read-out This article has

More information

Design of a High-Resolution and High-Sensitivity Scintillation Crystal Array for PET With Nearly Complete Light Collection

Design of a High-Resolution and High-Sensitivity Scintillation Crystal Array for PET With Nearly Complete Light Collection 2236 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 49, NO. 5, OCTOBER 2002 Design of a High-Resolution and High-Sensitivity Scintillation Crystal Array for PET With Nearly Complete Light Collection Craig

More information

Characterization of a 64 Channel PET Detector Using Photodiodes for Crystal Identification *

Characterization of a 64 Channel PET Detector Using Photodiodes for Crystal Identification * Characterization of a 64 Channel PET Detector Using Photodiodes for Crystal Identification * J. S. Huber, Member, IEEE, W.W. Moses, Senior Member, IEEE, S.E. Derenzo, Senior Member, IEEE, M.H. Ho, M.S.

More information

Lawrence Berkeley National Laboratory Recent Work

Lawrence Berkeley National Laboratory Recent Work Lawrence Berkeley National Laboratory Recent Work Title Trends in PET imaging Permalink https://escholarship.org/uc/item/21m4690s Journal Nuclear Instruments and Methods in Physics Research A, 471(1/2/2008)

More information

Development of the LBNL Positron Emission Mammography Camera

Development of the LBNL Positron Emission Mammography Camera Development of the LBNL Positron Emission Mammography Camera J.S. Huber, Member, IEEE, W.S. Choong, Member, IEEE, J. Wang, Member, IEEE, J.S. Maltz, Member, IEEE, J. Qi, Member, IEEE, E. Mandelli, Member,

More information

Investigation of low noise, low cost readout electronics for high sensitivity PET systems based on Avalanche Photodiode arrays

Investigation of low noise, low cost readout electronics for high sensitivity PET systems based on Avalanche Photodiode arrays Investigation of low noise, low cost readout electronics for high sensitivity PET systems based on Avalanche Photodiode arrays Frezghi Habte, Member, IEEE and Craig S.Levin, Member, IEEE Abstract A compact,

More information

Performance Assessment of Pixelated LaBr 3 Detector Modules for TOF PET

Performance Assessment of Pixelated LaBr 3 Detector Modules for TOF PET Performance Assessment of Pixelated LaBr 3 Detector Modules for TOF PET A. Kuhn, S. Surti, Member, IEEE, J. S. Karp, Senior Member, IEEE, G. Muehllehner, Fellow, IEEE, F.M. Newcomer, R. VanBerg Abstract--

More information

Simulation and evaluation of a cost-effective high-performance brain PET scanner.

Simulation and evaluation of a cost-effective high-performance brain PET scanner. Research Article http://www.alliedacademies.org/biomedical-imaging-and-bioengineering/ Simulation and evaluation of a cost-effective high-performance brain PET scanner. Musa S Musa *, Dilber U Ozsahin,

More information

Design of a High Resolution and High Sensitivity Scintillation Crystal Array with Nearly Perfect Light Collection

Design of a High Resolution and High Sensitivity Scintillation Crystal Array with Nearly Perfect Light Collection Design of a High Resolution and High Sensitivity Scintillation Crystal Array with Nearly Perfect Light Collection Craig S. Levin, Member, IEEE Abstract-- Spatial resolution improvements in Positron Emission

More information

Development of PET using 4 4 Array of Large Size Geiger-mode Avalanche Photodiode

Development of PET using 4 4 Array of Large Size Geiger-mode Avalanche Photodiode 2009 IEEE Nuclear Science Symposium Conference Record M09-8 Development of PET using 4 4 Array of Large Size Geiger-mode Avalanche Photodiode K. J. Hong, Y. Choi, J. H. Kang, W. Hu, J. H. Jung, B. J. Min,

More information

2594 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 56, NO. 5, OCTOBER /$ IEEE

2594 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 56, NO. 5, OCTOBER /$ IEEE 2594 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 56, NO. 5, OCTOBER 2009 Investigation of Depth of Interaction Encoding for a Pixelated LSO Array With a Single Multi-Channel PMT Yongfeng Yang, Member, IEEE,

More information

764 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 3, JUNE 2004

764 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 3, JUNE 2004 764 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 3, JUNE 2004 Study of Low Noise Multichannel Readout Electronics for High Sensitivity PET Systems Based on Avalanche Photodiode Arrays Frezghi Habte,

More information

Design Studies of A High-Performance Onboard Positron Emission Tomography For Integrated Small Animal PET/CT/RT Radiation Research Systems

Design Studies of A High-Performance Onboard Positron Emission Tomography For Integrated Small Animal PET/CT/RT Radiation Research Systems Proceedings of the International MultiConference of Engineers and Computer Scientists 2018 Vol II Design Studies of A High-Performance Onboard Positron Emission Tomography For Integrated Small Animal PET/CT/RT

More information

60 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 54, NO. 1, FEBRUARY /$ IEEE

60 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 54, NO. 1, FEBRUARY /$ IEEE 60 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 54, NO. 1, FEBRUARY 2007 Prototype Parallel Readout System for Position Sensitive PMT Based Gamma Ray Imaging Systems Frezghi Habte, Member, IEEE, Peter D.

More information

Study of a Prototype VP-PET Imaging System Based on highly. Pixelated CdZnTe Detectors

Study of a Prototype VP-PET Imaging System Based on highly. Pixelated CdZnTe Detectors Study of a Prototype VP-PET Imaging System Based on highly Pixelated CdZnTe Detectors Zheng-Qian Ye 1, Ying-Guo Li 1, Tian-Quan Wang 1, Ya-Ming Fan 1, Yong-Zhi Yin 1,*, Xi-Meng Chen 1 Affiliations: 1 School

More information

First Applications of the YAPPET Small Animal Scanner

First Applications of the YAPPET Small Animal Scanner First Applications of the YAPPET Small Animal Scanner Guido Zavattini Università di Ferrara CALOR2 Congress, Annecy - FRANCE YAP-PET scanner Scintillator: YAP:Ce Size: matrix of 2x2 match like crystals

More information

A High-Resolution GSO-based Brain PET Camera

A High-Resolution GSO-based Brain PET Camera A High-Resolution GSO-based Brain PET Camera J.S. Karp', Senior Member IEEE, L.E. Adam', R.Freifelder', Member IEEE, G. Muehllehner3 Senior Member IEEE, F. Liu"', Student Member IEEE, S. Surti"', Student

More information

CHAPTER 8 GENERIC PERFORMANCE MEASURES

CHAPTER 8 GENERIC PERFORMANCE MEASURES GENERIC PERFORMANCE MEASURES M.E. DAUBE-WITHERSPOON Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America 8.1. INTRINSIC AND EXTRINSIC MEASURES 8.1.1.

More information

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002 PET Detectors William W. Moses Lawrence Berkeley National Laboratory March 26, 2002 Step 1: Inject Patient with Radioactive Drug Drug is labeled with positron (β + ) emitting radionuclide. Drug localizes

More information

Design Optimization of a Small-animal SPECT System Using LGSO Continuous Crystals and Micro Parallel-hole Collimators

Design Optimization of a Small-animal SPECT System Using LGSO Continuous Crystals and Micro Parallel-hole Collimators Journal of the Korean Physical Society, Vol. 67, No. 1, July 2015, pp. 224 231 Design Optimization of a Small-animal SPECT System Using LGSO Continuous Crystals and Micro Parallel-hole Collimators Joong

More information

DISCRETE crystal detector modules have traditionally been

DISCRETE crystal detector modules have traditionally been IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 53, NO. 5, OCTOBER 2006 2513 Performance Comparisons of Continuous Miniature Crystal Element (cmice) Detectors Tao Ling, Student Member, IEEE, Kisung Lee, and

More information

Monte Carlo Simulation Study of a Dual-Plate PET Camera Dedicated to Breast Cancer Imaging

Monte Carlo Simulation Study of a Dual-Plate PET Camera Dedicated to Breast Cancer Imaging IEEE Nuclear Science Symposium Conference Record M-9 Monte Carlo Simulation Study of a Dual-Plate PET Camera Dedicated to Breast Cancer Imaging Jin Zhang, Member, IEEE, Peter D. Olcott, Member, IEEE, Angela

More information

Design Optimization of a Small-animal SPECT System Using LGSO Continuous. Crystal and a Micro Parallel-hole Collimator

Design Optimization of a Small-animal SPECT System Using LGSO Continuous. Crystal and a Micro Parallel-hole Collimator 1 Design Optimization of a Small-animal SPECT System Using LGSO Continuous Crystal and a Micro Parallel-hole Collimator 1 Joong Hyun Kim, 2 Mikiko Ito, 2 Soo Mee Kim, 3 Seong Jong Hong, 2,4 Jae Sung Lee,

More information

Over the past decade, many small-animal PET scanners

Over the past decade, many small-animal PET scanners A Prototype PET Scanner with DOI-Encoding Detectors Yongfeng Yang 1, Yibao Wu 1, Jinyi Qi 1, Sara St. James 1, Huini Du 1, Purushottam A. Dokhale 2, Kanai S. Shah 2, Richard Farrell 2, and Simon R. Cherry

More information

SOLID state photodiode and avalanche photodiode scintillation

SOLID state photodiode and avalanche photodiode scintillation 2007 IEEE Nuclear Science Symposium Conference Record M14-1 Data acquisition system design for a 1 mm 3 resolution PSAPD-based PET system Peter D. Olcott,,Student Member, IEEE, Frances W. Y. Lau, Student

More information

Evaluation of Scatter Fraction and Count Rate Performance of Two Smallanimal PET scanners using dedicated phantoms

Evaluation of Scatter Fraction and Count Rate Performance of Two Smallanimal PET scanners using dedicated phantoms 2011 IEEE Nuclear Science Symposium Conference Record MIC18.M-36 Evaluation of Scatter Fraction and Count Rate Performance of Two Smallanimal PET scanners using dedicated phantoms Rameshwar Prasad, Student

More information

Simulations of the J-PET detector response with the GATE package

Simulations of the J-PET detector response with the GATE package Simulations of the J-PET detector response with the GATE package Author: pawel.kowalski@ncbj.gov.pl 22nd to 24th September 2014 II Symposium on Positron Emission Tomography Outline 1. Introduction 2. Simulation

More information

Investigation of a New Readout Scheme for High Resolution Scintillation Crystal Arrays Using Photodiodes

Investigation of a New Readout Scheme for High Resolution Scintillation Crystal Arrays Using Photodiodes 120s IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 44, NO. 3, JUNE 1997 Investigation of a New Readout Scheme for High Resolution Scintillation Crystal Arrays Using Photodiodes Craig S. Levin, Member, IEEE,

More information

Design Evaluation of A-PET: A High Sensitivity Animal PET Camera

Design Evaluation of A-PET: A High Sensitivity Animal PET Camera IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 50, NO. 5, OCTOBER 2003 1357 Design Evaluation of A-PET: A High Sensitivity Animal PET Camera S. Surti, Member, IEEE, J. S. Karp, Senior Member, IEEE, A. E. Perkins,

More information

Investigation of Solid-State Photomultipliers for Positron Emission Tomography Scanners

Investigation of Solid-State Photomultipliers for Positron Emission Tomography Scanners Journal of the Korean Physical Society, Vol. 50, No. 5, May 2007, pp. 1332 1339 Investigation of Solid-State Photomultipliers for Positron Emission Tomography Scanners Jae Sung Lee Department of Nuclear

More information

Pinhole collimator design for nuclear survey system

Pinhole collimator design for nuclear survey system Annals of Nuclear Energy 29 (2002) 2029 2040 www.elsevier.com/locate/anucene Pinhole collimator design for nuclear survey system Wanno Lee*, Gyuseong Cho Department of Nuclear Engineering, Korea Advanced

More information

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 3, JUNE Investigation of the Block Effect on Spatial Resolution in PET Detectors

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 3, JUNE Investigation of the Block Effect on Spatial Resolution in PET Detectors IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 3, JUNE 2005 599 Investigation of the Block Effect on Spatial Resolution in PET Detectors Nada Tomic, Student Member, IEEE, Christopher J. Thompson, Member,

More information

Development of an innovative LSO-SiPM detector module for high-performance Positron Emission Tomography

Development of an innovative LSO-SiPM detector module for high-performance Positron Emission Tomography Development of an innovative LSO-SiPM detector module for high-performance Positron Emission Tomography Maria Leonor Trigo Franco Frazão leonorfrazao@ist.utl.pt Instituto Superior Técnico, Lisboa, Portugal

More information

APD Quantum Efficiency

APD Quantum Efficiency APD Quantum Efficiency Development of a 64-channel APD Detector Module with Individual Pixel Readout for Submillimeter Spatial Resolution in PET Philippe Bérard a, Mélanie Bergeron a, Catherine M. Pepin

More information

LSO PET/CT Pico Performance Improvements with Ultra Hi-Rez Option

LSO PET/CT Pico Performance Improvements with Ultra Hi-Rez Option LSO PET/CT Pico Performance Improvements with Ultra Hi-Rez Option Y. Bercier, Member, IEEE, M. Casey, Member, IEEE, J. Young, Member, IEEE, T. Wheelock, Member, IEEE, T. Gremillion Abstract-- Factors which

More information

Study of Silicon Photomultipliers for Positron Emission Tomography (PET) Application

Study of Silicon Photomultipliers for Positron Emission Tomography (PET) Application Study of Silicon Photomultipliers for Positron Emission Tomography (PET) Application Eric Oberla 5 June 29 Abstract A relatively new photodetector, the silicon photomultiplier (SiPM), is well suited for

More information

Development of a Pixelated Detector for Clinical Positron and Single-photon Molecular Imaging

Development of a Pixelated Detector for Clinical Positron and Single-photon Molecular Imaging Journal of Medical and Biological Engineering, 32(5): 373-380 373 Development of a Pixelated Detector for Clinical Positron and Single-photon Molecular Imaging Hsin-Ching Liang 1,2 Meei-Ling Jan 1,* Jenn-Lung

More information

Electronic Instrumentation for Radiation Detection Systems

Electronic Instrumentation for Radiation Detection Systems Electronic Instrumentation for Radiation Detection Systems January 23, 2018 Joshua W. Cates, Ph.D. and Craig S. Levin, Ph.D. Course Outline Lecture Overview Brief Review of Radiation Detectors Detector

More information

A NOVEL CONCEPT FOR A POSITRON EMISSION TOMOGRAPHY SCANNER

A NOVEL CONCEPT FOR A POSITRON EMISSION TOMOGRAPHY SCANNER A NOVEL CONCEPT FOR A POSITRON EMISSION TOMOGRAPHY SCANNER An Undergraduate Research Scholars Thesis by BRIAN KELLY, MATTHEW LEE ELLIOT LEVIN and JEENA KHATRI Submitted to Honors and Undergraduate Research

More information

Celesteion Time-of-Flight Technology

Celesteion Time-of-Flight Technology Celesteion Time-of-Flight Technology Bing Bai, PhD Clinical Sciences Manager, PET/CT Canon Medical Systems USA Introduction Improving the care for every patient while providing a high standard care to

More information

Positron Emission Tomography (PET) Detectors with Depth-of- Interaction (DOI) Capability

Positron Emission Tomography (PET) Detectors with Depth-of- Interaction (DOI) Capability Biomed Eng Lett (2011) 1:70-81 DOI 10.1007/s13534-011-0019-6 REVIEW ARTICLE Positron Emission Tomography (PET) Detectors with Depth-of- Interaction (DOI) Capability Mikiko Ito, Seong Jong Hong and Jae

More information

Design and development of compact readout electronics with silicon photomultiplier array for a compact imaging detector *

Design and development of compact readout electronics with silicon photomultiplier array for a compact imaging detector * CPC(HEP & NP), 2012, 36(10): 973 978 Chinese Physics C Vol. 36, No. 10, Oct., 2012 Design and development of compact readout electronics with silicon photomultiplier array for a compact imaging detector

More information

NM Module Section 2 6 th Edition Christian, Ch. 3

NM Module Section 2 6 th Edition Christian, Ch. 3 NM 4303 Module Section 2 6 th Edition Christian, Ch. 3 Gas Filled Chamber Voltage Gas filled chamber uses Hand held detectors cutie pie Geiger counter Dose calibrators Cutie pie Chamber voltage in Ionization

More information

Combined micropet /MR System: Performance Assessment of the Full PET Ring with Split Gradients 4.8

Combined micropet /MR System: Performance Assessment of the Full PET Ring with Split Gradients 4.8 Combined micropet /MR System: Performance Assessment of the Full PET Ring with Split Gradients 4.8 UNIVERSITY OF CAMBRIDGE 1.2 Rob C. Hawkes 1, Tim D. Fryer 1, Alun J. Lucas 1,2, Stefan B. Siegel 3, Richard

More information

Initial evaluation of the Indiana small animal PET scanner

Initial evaluation of the Indiana small animal PET scanner Initial evaluation of the Indiana small animal PET scanner Ned C. Rouze, Member, IEEE, Victor C. Soon, John W. Young, Member, IEEE, Stefan Siegel, Member, IEEE, and Gary D. Hutchins, Member, IEEE Abstract

More information

An innovative detector concept for hybrid 4D-PET/MRI Imaging

An innovative detector concept for hybrid 4D-PET/MRI Imaging Piergiorgio Cerello (INFN - Torino) on behalf of the 4D-MPET* project *4 Dimensions Magnetic compatible module for Positron Emission Tomography INFN Perugia, Pisa, Torino; Polytechnic of Bari; University

More information

Solid-State Photomultiplier in CMOS Technology for Gamma-Ray Detection and Imaging Applications

Solid-State Photomultiplier in CMOS Technology for Gamma-Ray Detection and Imaging Applications Solid-State Photomultiplier in CMOS Technology for Gamma-Ray Detection and Imaging Applications Christopher Stapels, Member, IEEE, William G. Lawrence, James Christian, Member, IEEE, Michael R. Squillante,

More information

Simulation of Algorithms for Pulse Timing in FPGAs

Simulation of Algorithms for Pulse Timing in FPGAs 2007 IEEE Nuclear Science Symposium Conference Record M13-369 Simulation of Algorithms for Pulse Timing in FPGAs Michael D. Haselman, Member IEEE, Scott Hauck, Senior Member IEEE, Thomas K. Lewellen, Senior

More information

A high energy gamma camera using a multiple hole collimator

A high energy gamma camera using a multiple hole collimator ELSEVIER Nuclear Instruments and Methods in Physics Research A 353 (1994) 328-333 A high energy gamma camera using a multiple hole collimator and PSPMT SV Guru *, Z He, JC Ferreria, DK Wehe, G F Knoll

More information

LaBr 3 :Ce, the latest crystal for nuclear medicine

LaBr 3 :Ce, the latest crystal for nuclear medicine 10th Topical Seminar on Innovative Particle and Radiation Detectors 1-5 October 2006 Siena, Italy LaBr 3 :Ce, the latest crystal for nuclear medicine Roberto Pani On behalf of SCINTIRAD Collaboration INFN

More information

NIH Public Access Author Manuscript Nucl Instrum Methods Phys Res A. Author manuscript; available in PMC 2007 December 14.

NIH Public Access Author Manuscript Nucl Instrum Methods Phys Res A. Author manuscript; available in PMC 2007 December 14. NIH Public Access Author Manuscript Published in final edited form as: Nucl Instrum Methods Phys Res A. 2007 January 21; 570(3): 543 555. A prototype of very high resolution small animal PET scanner using

More information

Performance Evaluation of SiPM Detectors for PET Imaging in the Presence of Magnetic Fields

Performance Evaluation of SiPM Detectors for PET Imaging in the Presence of Magnetic Fields 2008 IEEE Nuclear Science Symposium Conference Record M02-4 Performance Evaluation of SiPM Detectors for PET Imaging in the Presence of Magnetic Fields Samuel España, Student Member, IEEE, Gustavo Tapias,

More information

LaBr 3 :Ce scintillation gamma camera prototype for X and gamma ray imaging

LaBr 3 :Ce scintillation gamma camera prototype for X and gamma ray imaging 8th International Workshop on Radiation Imaging Detectors Pisa 2-6 July 2006 LaBr 3 :Ce scintillation gamma camera prototype for X and gamma ray imaging Roberto Pani On behalf of SCINTIRAD Collaboration

More information

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 614 (2010) 308 312 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

Design and development of compact readout electronics with silicon photomultiplier array for a compact imaging detector

Design and development of compact readout electronics with silicon photomultiplier array for a compact imaging detector University of Wollongong Research Online Faculty of Engineering and Information Sciences - Papers: Part A Faculty of Engineering and Information Sciences 2012 Design and development of compact readout

More information

New Technology in Nuclear Medicine

New Technology in Nuclear Medicine New Technology in Nuclear Medicine Reed G. Selwyn, PhD, DABR Vice Chair of Research & Imaging Sciences Associate Professor and Chief, Medical Physics Dept. of Radiology, University of New Mexico Objectives

More information

How Gamma Camera s Head-Tilts Affect Image Quality of a Nuclear Scintigram?

How Gamma Camera s Head-Tilts Affect Image Quality of a Nuclear Scintigram? November 2014, Volume 1, Number 4 How Gamma Camera s Head-Tilts Affect Image Quality of a Nuclear Scintigram? Hojjat Mahani 1,2, Alireza Kamali-Asl 3, *, Mohammad Reza Ay 2, 4 1. Radiation Application

More information

PET is a noninvasive, diagnostic imaging technique that

PET is a noninvasive, diagnostic imaging technique that Performance Measurement of the micropet Focus 120 Scanner Jin Su Kim 1,2, Jae Sung Lee 1,2, Ki Chun Im 3, Su Jin Kim 1,2, Seog-Young Kim 3, Dong Soo Lee 1,2, and Dae Hyuk Moon 3 1 Department of Nuclear

More information

MPPC and Liquid Xenon technologies from particle physics to medical imaging

MPPC and Liquid Xenon technologies from particle physics to medical imaging CANADA S NATIONAL LABORATORY FOR PARTICLE AND NUCLEAR PHYSICS Owned and operated as a joint venture by a consortium of Canadian universities via a contribution through the National Research Council Canada

More information

Noise Characteristics of the FORE+OSEM(DB) Reconstruction Method for the MiCES PET Scanner

Noise Characteristics of the FORE+OSEM(DB) Reconstruction Method for the MiCES PET Scanner Noise Characteristics of the FORE+OSEM(DB) Reconstruction Method for the MiCES PET Scanner Kisung Lee, Member, IEEE, Paul E. Kinahan, Senior Member, Robert S. Miyaoka, Member, IEEE, Jeffrey A. Fessler,

More information

1396 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 5, OCTOBER 2005

1396 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 5, OCTOBER 2005 1396 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 5, OCTOBER 2005 Performance Amelioration for Small Animal SPECT Using Optimized Pinhole Collimator and Image Correction Technique Tae Yong Song,

More information

Development of Personal Dosimeter Using Electronic Dose Conversion Method

Development of Personal Dosimeter Using Electronic Dose Conversion Method Proceedings of the Korean Nuclear Spring Meeting Gyeong ju, Korea, May 2003 Development of Personal Dosimeter Using Electronic Dose Conversion Method Wanno Lee, Bong Jae Lee, and Chang Woo Lee Korea Atomic

More information

PET has evolved from a research tool for studying

PET has evolved from a research tool for studying Virtual-Pinhole PET Yuan-Chuan Tai 1,2, Heyu Wu 1, Debashish Pal 3, and Joseph A. O Sullivan 4 1 Department of Radiology, Washington University, St. Louis, Missouri; 2 Alvin J. Siteman Cancer Center, Washington

More information

Development of an amplifier module for measuring X-ray spectra using a photomultiplier tube

Development of an amplifier module for measuring X-ray spectra using a photomultiplier tube Annual Report of Iwate Medical University Center for Liberal Arts and Sciences No. 53(2018), 1-6. 1 Development of an amplifier module for measuring X-ray spectra using a photomultiplier tube Eiichi SATO

More information

Importance of Precise Timing for Medical Diagnostic Devices

Importance of Precise Timing for Medical Diagnostic Devices Importance of Precise Timing for Medical Diagnostic Devices M.C.S. Williams a,b, A. Zichichi a,b,c and the CERN-Bologna group. a CERN Geneva, Switzerland b INFN and Dipartimento di Fisica e Astronomia,

More information

THE increasing interest on pinhole collimation of gamma

THE increasing interest on pinhole collimation of gamma IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 54, NO. 3, JUNE 2007 469 CsI(Tl) Micro-Pixel Scintillation Array for Ultra-high Resolution Gamma-ray Imaging M. N. Cinti, R. Scafè, R. Pellegrini, C. Trotta,

More information

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE A. Miceli ab, R. Thierry a, A. Flisch a, U. Sennhauser a, F. Casali b a Empa - Swiss Federal Laboratories for

More information

Development of FPGA-based Coincidence Units with Veto Function

Development of FPGA-based Coincidence Units with Veto Function Biomed Eng Lett (2011) 1:27-31 DOI 10.1007/s13534-011-0001-3 ORIGINAL ARTICLE Development of FPGA-based Coincidence Units with Veto Function Guen Bae Ko, Hyun Suk Yoon, Sun Il Kwon, Seong Jong Hong, Dong

More information

Detector technology challenges for nuclear medicine and PET

Detector technology challenges for nuclear medicine and PET Nuclear Instruments and Methods in Physics Research A 513 (2003) 1 7 Detector technology challenges for nuclear medicine and PET Paul K. Marsden Guy s and St. Thomas Clinical PET Centre, King s College

More information

Primer on molecular imaging technology

Primer on molecular imaging technology Primer on molecular imaging technology Craig S. Levin Division of Nuclear Medicine, Department of Radiology and Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, 300

More information

Solid State Photomultiplier: Noise Parameters of Photodetectors with Internal Discrete Amplification

Solid State Photomultiplier: Noise Parameters of Photodetectors with Internal Discrete Amplification Solid State Photomultiplier: Noise Parameters of Photodetectors with Internal Discrete Amplification K. Linga, E. Godik, J. Krutov, D. Shushakov, L. Shubin, S.L. Vinogradov, and E.V. Levin Amplification

More information

A Continuous Crystal Detector for TOF PET

A Continuous Crystal Detector for TOF PET 1 A Continuous Crystal Detector for TOF PET T. Szczęśniak, Member, IEEE, M. Moszyński, Fellow, IEEE, Ł. Świderski, Member, IEEE, A. Nassalski, Member, IEEE, A. Syntfeld-KaŜuch, Member, IEEE, P. Ojala,

More information

A new operative gamma camera for Sentinel Lymph Node procedure

A new operative gamma camera for Sentinel Lymph Node procedure A new operative gamma camera for Sentinel Lymph Node procedure A physicist device for physicians Samuel Salvador, Virgile Bekaert, Carole Mathelin and Jean-Louis Guyonnet 12/06/2007 e-mail: samuel.salvador@ires.in2p3.fr

More information

Study of the performance of a novel 1 mm resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation

Study of the performance of a novel 1 mm resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation Study of the performance of a novel 1 mm resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation Jin Zhang, a Peter D. Olcott, b Garry Chinn, c Angela M.

More information

Development of Solid-State Detector for X-ray Computed Tomography

Development of Solid-State Detector for X-ray Computed Tomography Proceedings of the Korea Nuclear Society Autumn Meeting Seoul, Korea, October 2001 Development of Solid-State Detector for X-ray Computed Tomography S.W Kwak 1), H.K Kim 1), Y. S Kim 1), S.C Jeon 1), G.

More information

Highlights of Poster Session I: SiPMs

Highlights of Poster Session I: SiPMs Highlights of Poster Session I: SiPMs Yuri Musienko* FNAL(USA)/INR(Moscow) NDIP 2011, Lyon, 5.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 1 Poster Session I 21 contributions on SiPM characterization and

More information

2448 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 57, NO. 5, OCTOBER 2010

2448 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 57, NO. 5, OCTOBER 2010 2448 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 57, NO. 5, OCTOBER 2010 Development of an APD-Based PET Module and Preliminary Resolution Performance of an Experimental Prototype Gantry Jun Kataoka, Hidenori

More information

Currently, the spatial resolution of most dedicated smallanimal

Currently, the spatial resolution of most dedicated smallanimal A Prototype High-Resolution Small-Animal PET Scanner Dedicated to Mouse Brain Imaging Yongfeng Yang 1,2, Julien Bec 1, Jian Zhou 1, Mengxi Zhang 1, Martin S. Judenhofer 1, Xiaowei Bai 1, Kun Di 1, Yibao

More information

Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud

Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud University of Groningen Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you

More information

Exprerimental Evaluation of a Dedicated Pinhole SPECT System for Small Animal Imaging and Scintimammography

Exprerimental Evaluation of a Dedicated Pinhole SPECT System for Small Animal Imaging and Scintimammography ETASR - Engineering, Technology & Applied Science Research Vol. 1, o. 1, 211, 17-22 17 Exprerimental Evaluation of a Dedicated Pinhole SPECT System for Small Animal Imaging and Scintimammography S. David

More information

PET Performance Evaluation of MADPET4: A Small Animal PET Insert for a 7-T MRI Scanner

PET Performance Evaluation of MADPET4: A Small Animal PET Insert for a 7-T MRI Scanner PET Performance Evaluation of MADPET4: A Small Animal PET Insert for a 7-T MRI Scanner September, 2017 Results submitted to Physics in Medicine & Biology Negar Omidvari 1, Jorge Cabello 1, Geoffrey Topping

More information

Journal of Radiation Protection and Research

Journal of Radiation Protection and Research 1) WOO JIN JO et al: CZT BASED PET SYSTEM IN KAERI Journal of Radiation Protection and Research pissn 2508-1888 eissn 2466-2461 http://dx.doi.org/10.14407/jrpr.2016.41.2.081 Paper Received July 17, 2015

More information

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM Preamplifiers and amplifiers The current from PMT must be further amplified before it can be processed and counted (the number of electrons yielded

More information

Future directions in Nuclear Medicine Instrumentation

Future directions in Nuclear Medicine Instrumentation Future directions in Nuclear Medicine Instrumentation Where are we going - and why? First, the disclosure list My group at the University of Washington has research support from: NIH DOE General Electric

More information

Thomas Frach, Member, IEEE, Walter Ruetten, Member, IEEE, Klaus Fiedler, Gunnar Maehlum, Member, IEEE, Torsten Solf, and Andreas Thon

Thomas Frach, Member, IEEE, Walter Ruetten, Member, IEEE, Klaus Fiedler, Gunnar Maehlum, Member, IEEE, Torsten Solf, and Andreas Thon Assessment of Photodiodes as a Light Detector for PET Scanners Thomas Frach, Member, IEEE, Walter Ruetten, Member, IEEE, Klaus Fiedler, Gunnar Maehlum, Member, IEEE, Torsten Solf, and Andreas Thon Abstract

More information

Design Studies for a PET Detector Module Using a PIN Photodiode to Measure Depth of Interaction

Design Studies for a PET Detector Module Using a PIN Photodiode to Measure Depth of Interaction r.- v;» 4-5; +6 1*; LBL-3487 3 UC-406. Preprint SW 3 UNIVERSITY OF CALIFORNIA Submitted to IEEE Transactions 0n Nuclear Science Design Studies for a PET Detector Module Using a PIN Photodiode to Measure

More information

Design, Calibration, and Evaluation of Depth-of- Interaction-Capable PET Detector Modules

Design, Calibration, and Evaluation of Depth-of- Interaction-Capable PET Detector Modules Texas Medical Center Library DigitalCommons@TMC UT GSBS Dissertations and Theses (Open Access) Graduate School of Biomedical Sciences 12-2012 Design, Calibration, and Evaluation of Depth-of- Interaction-Capable

More information

Development of a simplified readout for a compact gamma camera based on 2 2 H8500 multi-anode PSPMT array

Development of a simplified readout for a compact gamma camera based on 2 2 H8500 multi-anode PSPMT array University of Wollongong Research Online Faculty of Engineering and Information Sciences - Papers: Part A Faculty of Engineering and Information Sciences 2010 Development of a simplified readout for a

More information

POSITRON emission tomography (PET) scanners, which

POSITRON emission tomography (PET) scanners, which 882 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 3, JUNE 2008 An Investigation Into the Use of Geiger-Mode Solid-State Photomultipliers for Simultaneous PET and MRI Acquisition Seong Jong Hong, In

More information

A PET detector module using FPGA-only MVT digitizers

A PET detector module using FPGA-only MVT digitizers A PET detector module using FPGA-only MVT digitizers Daoming Xi, Student Member, IEEE, Chen Zeng, Wei Liu, Student Member, IEEE, Xiang Liu, Lu Wan, Student Member, IEEE, Heejong Kim, Member, IEEE, Luyao

More information

Development of a High-Resolution and Depth-of- Interaction Capable Detector for Time-of-Flight PET

Development of a High-Resolution and Depth-of- Interaction Capable Detector for Time-of-Flight PET Development of a High-Resolution and Depth-of- Interaction Capable Detector for Time-of-Flight PET Srilalan Krishnamoorthy, Member, IEEE, Rony I. Wiener, Madhuri Kaul, Joseph Panetta, Joel S. Karp, Senior

More information

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image Introduction Chapter 16 Diagnostic Radiology Radiation Dosimetry I Text: H.E Johns and J.R. Cunningham, The physics of radiology, 4 th ed. http://www.utoledo.edu/med/depts/radther In diagnostic radiology

More information

CURRENT AND FUTURE TRENDS IN PET INSTRUMENTATION

CURRENT AND FUTURE TRENDS IN PET INSTRUMENTATION ANALELE ŞTIINŢIFICE ALE UNIVERSITĂŢII AL. I. CUZA IAŞI Tomul III, s. Biofizică, Fizică medicală şi Fizica mediului 2007 CURRENT AND FUTURE TRENDS IN PET INSTRUMENTATION D. Mihăilescu 1, C. Borcia 1 KEYWORDS:

More information

Defense Technical Information Center Compilation Part Notice

Defense Technical Information Center Compilation Part Notice UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADPO 11245 TITLE: An Analysis System for PET Detector DISTRIBUTION: Approved for public release, distribution unlimited This paper

More information

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland)

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland) Danube School on Instrumentation in Elementary Particle & Nuclear Physics University of Novi Sad, Serbia, September 8 th 13 th, 2014 Lab Experiment: Characterization of Silicon Photomultipliers Dominik

More information

Under-sampling in PET scanners as a source of image blurring

Under-sampling in PET scanners as a source of image blurring Nuclear Instruments and Methods in Physics Research A 545 (2005) 436 445 www.elsevier.com/locate/nima Under-sampling in PET scanners as a source of image blurring C.J. Thompson, S.St. James, N. Tomic Montreal

More information

Photomultiplier Tube

Photomultiplier Tube Nuclear Medicine Uses a device known as a Gamma Camera. Also known as a Scintillation or Anger Camera. Detects the release of gamma rays from Radionuclide. The radionuclide can be injected, inhaled or

More information