AnySensor (1.0 /1.5)

Size: px
Start display at page:

Download "AnySensor (1.0 /1.5)"

Transcription

1 HQ MM-kcg Dental Digital Imaging Radiography System AnySensor (1.0 /1.5)

2 Cutting-edge CMOS Technology

3 CMOS? CCD? CCD CMOS Past - Particular Process -High Quality & High Cost - General Process - Noise Problem Present - Fit to TDI System (Time Delay Integration) - Fit to Panoramic X-ray - High Quality & Low Cost (By the advance in technology) - e.g. Canon 12Milion pixels Digital Camera (No.1 company in digital camera) -e.g. Schick Intra-Oral Sensor (CDR) Vatch Intra-Oral Sensor (AnySensor)

4 FOS? FOP? FOS FOP FOS Product Image

5 AnySensor Technology Area Sensor For Medical CT Sensor Panoramic & Cephalometric Sensor Intra-Oral Sensor Cephalometric Image from Oneshot

6 AnySensor Technology Wafer & Manufacturing Facilities

7 AnySensor Feature How to get an image

8 AnySensor Feature Excellent Image Quality based on advanced CMOS Technology Optimized Sensor Dimension for human oral structure [1.5 size for Adult / 1.0 size for Children USB 2.0 interface No need extra power supply Model AnySensor100 AnySensor150 Detector FOS on CMOS External Dimension 34 * 23 mm 36 * 27mm Acquisition Area 30*20mm 32*24mm 24 External Thickness Data Cable Length 4.8 mm 16 bit 3 m

9 AnySensor Feature User friendly S/W User friendly S/W ; Upgradeable + Free of charge

10 AnySensor Feature Cone-indicator Paralleling radiography Bisecting angle radiography

11 Provided Accessory Easy for AnySensor Positioning Flexible holder for AnySensor

12 FAQ

13 1. Pixel Size and Image Quality 1-1. Factors of effecting Image Quality Sensor Sensitivity, Sensor Pixel Size, Screen Resolution, Image Processing SW, X-Ray Quality, Accuracy of Focal Layer, Patient positioning, ect Sensor Structure and Image Quality 1) General Recognition : Small Pixel Size -> Good Sensor -> Good Image??? 2) Structure of Image Sensor Module X-ray -- CsI (transferring X-ray to Visible Light) FOP (FOS) -- Detector The important thing in the sensor design is for increasing the life time of the sensor module and reducing the scattered light

14 2. CCD & CMOS Image Sensor 2-1. Structure CCD Charge Coupled Device Each pixel can transfer its electric charge to one or other of its neighbors. The last pixel converts the accumulated electronic charge so that the chip outputs digital bits. CMOS Complementary Metal Oxide Semiconductor Each pixel has its own charge-to-voltage conversion so that the chip outputs digital bits. Intra oral sensor, CT = CMOS (area sensor) Panoramic X-ray = CCD (liner sensor)

15 Which is better? CCD or CMOS Old-fashioned Issue CCD CMOS Past - Particular Process - High Quality & High Cost - Fit to TDI System (Time Delay Integration) - General Process - Noise Problem - High Quality & Low Cost (By the advance in technology) Now - Fit to Panoramic X-ray - e.g. Canon 12Milion pixels Digital it Camera (No.1 company in digital camera) - e.g. Schick : Intra-Oral Sensor

16 3. Sensor Resolution Line Pair - Unit of sensor resolution : Line Pair Per mm (lp/mm) - Theoretical formula = 1mm / (2 x Pixel Size) - e.g. Pixel Size 25μm : 1000 / (2 x 25) = 20 lp/mm 3-2. Line Phantom Real Measurement by Line Phantom Difference between theoretical ti Line Pair and real Line Pair - The other factors are not perfect : X-ray Scattering, Noise, Image processing, etc. - Manufacturers do not calculate the effect of Pixel Binning on purpose - Have no Standard Method to evaluate Line Pair by using Line Phantom (Under discussion at American Radiology Association)

17 4. Number of bit (Gray scale) and Image Quality 12 bit (2 12 = 4,096 ) data provides 16 times higher image quality than that of 8 bit data(256). A B A B Image quality of A is different from that of B in 12 bit data, But same in 8 bit data

18 5. Wireless Intra Oral Sensor Do you have the wireless intra-oral sensor? 1) Common Technology - The wireless communication is already commercialized - e.g. Mobile, Intra Oral Camera, etc. 2) The Problems & The Issues - Insufficient Power Supply Only few shots on full charge (Charge time is around 3 hours) - Unstable Telecommunication 3) The Failure of Example : Schick

19 6. Life time of Sensor 6-1) Life time (Experimental Data in our R&D Center) - 40,000 times continuative photographing for Panoramic sensor - 70,000 times continuative photographing for AnySensor (on going) 6-2) Term of Guarantee - Guaranteed for 1 year. - In case that customer wants longer terms of guarantee, the price condition could be variable. 6-3) How to operate the sensor for using longer time? - Prevent from the shock. - Sensor is designed to withstand high temperature and sudden changed in temperature. However we strongly recommend to keep our sensor from -5 to 25.

20 Recommended Exposure Time X-ray Device ESX (Vatech) AnyRay (Vatech) Other A (DC Type) Other B (DC Type) Kvp, ma 65Kvp, 5 ma 60Kvp, 2 ma 70Kvp, 7 ma 65Kvp, 7 ma FDD 28cm 18cm 28cm 18cm Upper Jaw/Anterior 0.25sec 0.25sec 0.20sec 0.16sec Upper Jaw/Canine 0.25sec 0.25sec 0.20sec 0.16sec Upper Jaw/Posterior 0.40sec 0.40sec 0.30sec 0.20sec Lower Jaw/Anterior 0.25sec 0.25sec 0.16sec 0.12sec Lower Jaw/Canine 0.25sec 0.25sec 0.16sec 0.14sec Lower Jaw/Posterior 0.30sec 0.30sec 0.25sec 0.20sec

21 Thank You

PRODUCT CATALOGUE 20 17

PRODUCT CATALOGUE 20 17 PRODUCT CATALOGUE 20 17 I-View CMOS Intraoral sensor Trident uses the best of CMOS technology to create I-View: an innovative sensor to get better diagnosis with outstanding images, saving both valuable

More information

Panoura 18S. 3-In-1 Panoramic System. ImageWorks. Autofocus Imaging. Multifocal layer technology

Panoura 18S. 3-In-1 Panoramic System.   ImageWorks. Autofocus Imaging. Multifocal layer technology Panoura 18S 3-In-1 Panoramic System P A N O R A M I C 3 D I M A G I N G C E P H A L O M E T R I C T M J V I E W S I N U S E X A M Autofocus Imaging Multifocal layer technology 4,500 images in a single

More information

make it easy, with Ray

make it easy, with Ray Lower dose - Quick scan times - Pulsed X-ray technology - Multiple scan modes 3 Dedicated detectors - Reliable performance - No damage - Long life span Easy upgrade - Ready to upgrade CBCT & Cephalometric

More information

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX. The premium intraoral X-ray unit... ProX Intraoral X-ray PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX. This advanced unit provides

More information

Comprehensive product portfolio. FONA, the most exciting new brand in dental. ALL THE ADVANTAGES OF DIGITAL Intraoral Imaging

Comprehensive product portfolio. FONA, the most exciting new brand in dental. ALL THE ADVANTAGES OF DIGITAL Intraoral Imaging Comprehensive product portfolio Treatment centers Instruments Laser Hygiene 3D and Panoramic x-rays Intraoral x-rays Intraoral sensors Phosphor plate scanner FONA, the most exciting new brand in dental

More information

X-Ray/ Digital Imaging

X-Ray/ Digital Imaging Chapter 20 X-Ray/ Digital Imaging Carestream - Intraoral Cameras 852 Intraoral X-Rays 855 Digital Sensors 857 Intraoral Imaging Plate System 860 Extraoral Imaging System 862 Intraoral Scanners 868 CBCT

More information

ALL THE ADVANTAGES OF DIGITAL Intraoral Imaging

ALL THE ADVANTAGES OF DIGITAL Intraoral Imaging ALL THE ADVANTAGES OF DIGITAL Intraoral Imaging FONA Intraoral Imaging PATIENT COMFORT AND EASE OF USE Plate sizes and positioning just as with traditional film allowing ease of use, patient comfort and

More information

One standard. Two solutions.

One standard. Two solutions. One standard. Two solutions. 6100 KODAK RVG 6100 Digital Radiography System 5100 KODAK RVG 5100 Digital Radiography System 6100 5100 KODAK RVG 6100 Digital Radiography System KODAK RVG 5100 Digital Radiography

More information

ART Plus CdTe-Sensor Technology

ART Plus CdTe-Sensor Technology ART Plus CdTe-Sensor Technology Best Sensor Technology for Great Diagnostic Value The AJAT sensor provides the unique opportunity among panoramic systems to adjust the focal layer to the ideal for the

More information

Cutting-edge image quality

Cutting-edge image quality ENGLISH Cutting-edge image quality The innovative Planmeca ProSensor intraoral sensor sets new standards for imaging in dental practice. Planmeca ProSensor is a unique combination of high-end patient-centred

More information

INTRAORAL X-RAY THE INTRAORAL X-RAY UNIT FAMILY A FLEXIBLE START IN THE WORLD OF IMAGE QUALITY. SIRONA.COM

INTRAORAL X-RAY THE INTRAORAL X-RAY UNIT FAMILY A FLEXIBLE START IN THE WORLD OF IMAGE QUALITY. SIRONA.COM INTRAORAL X-RAY THE INTRAORAL X-RAY UNIT FAMILY A FLEXIBLE START IN THE WORLD OF IMAGE QUALITY. SIRONA.COM THE PERFECT X-RAY PLATFORM FOR EVERY PRACTICE. Intraoral x-rays are a part of the every - day

More information

DIGITAL IMAGING Recognise the importance of quality assurance

DIGITAL IMAGING Recognise the importance of quality assurance DIGITAL IMAGING Recognise the importance of quality assurance There are two types of digital image receptor both of which capture a two dimensional image of the three dimensional patient. These are Computed

More information

Time Delay Integration (TDI), The Answer to Demands for Increasing Frame Rate/Sensitivity? Craige Palmer Assistant Sales Manager

Time Delay Integration (TDI), The Answer to Demands for Increasing Frame Rate/Sensitivity? Craige Palmer Assistant Sales Manager Time Delay Integration (TDI), The Answer to Demands for Increasing Frame Rate/Sensitivity? Craige Palmer Assistant Sales Manager Laser Scanning Microscope High Speed Gated PMT Module High Speed Gating

More information

DENTAL LINE. Dental Panoramic - Digital & Film

DENTAL LINE. Dental Panoramic - Digital & Film DENTAL LINE Dental Panoramic - Digital & Film Evolution comes from experience Rotograph Evo takes the experience of five decades of dedication to X-ray diagnostic imaging to the next level. You can rely

More information

AeroDR 2S. Wireless Digital Radiography System

AeroDR 2S. Wireless Digital Radiography System AeroDR 2S Wireless Digital Radiography System AERODR 2S 2 DIGITIZE YOUR WORKFLOW Upgrade your existing analog X-ray room in just a few simple steps with Konica Minolta s lightest 14x17 CsI Digital Detector

More information

Your Partner in Digital Success 2013/02

Your Partner in Digital Success 2013/02 Your Partner in Digital Success 2013/02 Your Partner in Digital Success, PaX-i Superior Image Quality - Optimal image for accurate diagnosis Two Built-In Sensors - Specialized sensors for Pano & Ceph -

More information

CS The Ideal Solution for the Transition to Digital

CS The Ideal Solution for the Transition to Digital CS 7400 The Ideal Solution for the Transition to Digital Larger, high quality images An affordable, cost-effective digital option While many digital radiography systems may require purchasing new equipment,

More information

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR This presentation is a professional collaboration of development time prepared by: Rex Christensen Terri Jurkiewicz and Diane Kawamura New Technology https://www.youtube.com/watch?v=ptkzznazb 7U COMPUTED

More information

Digital Panoramic X- Ray unit. Product Data

Digital Panoramic X- Ray unit. Product Data Digital Panoramic X- Ray unit Product Data Standard examination programs Standard panoramic: adult/child panoramic exam TMJ open/close mouth: 4 slices are taken in the same image (left/right condyle, open/close

More information

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

Unit thickness. Unit area. σ = NΔX = ΔI / I 0 Unit thickness I 0 ΔI I σ = ΔI I 0 NΔX = ΔI / I 0 NΔX Unit area Δx Average probability of reaction with atom for the incident photons at unit area with the thickness of Delta-X Atom number at unit area

More information

Shad-o-Box HS Product Family

Shad-o-Box HS Product Family Shad-o-Box HS Product Family DATASHEET Overview Key Features Large active area up to 10x15 cm Up to 10 lp/mm resolution Gigabit Ethernet interface (Camera Link optional) 14-bit digital video output Energy

More information

Photostimulable phosphor plates (PSPs)

Photostimulable phosphor plates (PSPs) DIGITAL IMAGING Digital imaging Photostimulable phosphor plates (PSPs) Indirect digital PSPs are composed of a polyester base with a phosphor layer (europium activated barium fluorohalide) on one side.

More information

Picasso-Trio 3-D Dental Imaging

Picasso-Trio 3-D Dental Imaging Picasso-Trio 3-D Dental Imaging Digital Panoramic & Cephalometric, CBCT X-ray Imaging System 3 in 1 System Product Data Model Picasso-Trio - NP Panoramic only [CT upgradeable] Picasso-Trio - NC Panoramic

More information

Topic 9 - Sensors Within

Topic 9 - Sensors Within Topic 9 - Sensors Within Learning Outcomes In this topic, we will take a closer look at sensor sizes in digital cameras. By the end of this video you will have a better understanding of what the various

More information

DIGITAL IMAGING WITHOUT LIMITS. Your Complete Digital X-Ray Solution. Wireless. Flexible. Every image SIZE.

DIGITAL IMAGING WITHOUT LIMITS. Your Complete Digital X-Ray Solution. Wireless. Flexible. Every image SIZE. DIGITAL IMAGING WITHOUT LIMITS. Your Complete Digital X-Ray Solution. Wireless. Flexible. Every image SIZE. C l a s s i c D u o I n t r a o r a l Digital Imaging Without Limits ScanX digital radiography

More information

Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced Radiation

Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced Radiation Diagnostic and Imaging Equipment Treatment Units Handpieces and Instruments Endodontic Systems Laser Equipment Laboratory Devices Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced

More information

Charge-Coupled Device (CCD) Detectors pixel silicon chip electronics cryogenics

Charge-Coupled Device (CCD) Detectors pixel silicon chip electronics cryogenics Charge-Coupled Device (CCD) Detectors As revolutionary in astronomy as the invention of the telescope and photography semiconductor detectors a collection of miniature photodiodes, each called a picture

More information

Digital imaging à la carte

Digital imaging à la carte I-Max Plus Digital imaging à la carte Digital imaging à la carte I-Max Plus offers a wide selection of programs. The first Dual System, I-Max Plus provides unmatched advantages that will enhance your standing

More information

I AM CONFIDENT SOPIX SERIES TECHNICAL SPECIFICATIONS. A successful X-ray every time with minimal exposure to radiation

I AM CONFIDENT SOPIX SERIES TECHNICAL SPECIFICATIONS. A successful X-ray every time with minimal exposure to radiation TECHNICAL SPECIFICATIONS Size 1 External dimensions... 25 x 39mm Active surface area...600mm2 (20 x 30mm) Number of pixels... 1.50million SOPIX / SOPIX inside system Technology...CMOS + scintillator+ optic

More information

TDI Imaging: An Efficient AOI and AXI Tool

TDI Imaging: An Efficient AOI and AXI Tool TDI Imaging: An Efficient AOI and AXI Tool Yakov Bulayev Hamamatsu Corporation Bridgewater, New Jersey Abstract As a result of heightened requirements for quality, integrity and reliability of electronic

More information

DELWORKS DR MEDICAL. take the next step

DELWORKS DR MEDICAL. take the next step DELWORKS DR MEDICAL take the next step DELWORKS MEDICAL DR If you are thinking of taking the next step to digital radiography, consider a DelWorks Medical DR Retrofit Package, the easy and affordable way

More information

Dedicated Veterinary Imaging Solutions Digital, CR and Analog Imaging Solutions for any size patient and any size budget.

Dedicated Veterinary Imaging Solutions Digital, CR and Analog Imaging Solutions for any size patient and any size budget. by Dedicated Veterinary Imaging Solutions Digital, CR and Analog Imaging Solutions for any size patient and any size budget. Serving the Veterinary Profession for Over 75 Years. ... We See Things Differently

More information

you can Portable DR with High Sensitivity. Less is more. CXDI-501C DIGITAL RADIOGRAPHY SYSTEM

you can Portable DR with High Sensitivity. Less is more. CXDI-501C DIGITAL RADIOGRAPHY SYSTEM you can Portable DR with High Sensitivity. Less is more. CXDI-501C DIGITAL RADIOGRAPHY SYSTEM High quality DR technology from a dose-efficient, thin and lightweight portable Flat Panel Detector Time Reduction

More information

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp Dose Reduction and Image Preservation After the Introduction of a into the LODOX Statscan unit above 110 kvp Abstract: CJ Trauernicht 1, C Rall 1, T Perks 2, G Maree 1, E Hering 1, S Steiner 3 1) Division

More information

VistaCam camera systems for successful diagnostics and communication

VistaCam camera systems for successful diagnostics and communication VistaCam camera systems for successful diagnostics and communication COMPRESSED AIR SUCTION IMAGING DENTAL CARE HYGIENE Win your patients trust with great images Intraoral camera systems from Dürr Dental

More information

Medical Imaging. Digital R/F remote controlled table. radiology ahead

Medical Imaging. Digital R/F remote controlled table. radiology ahead Medical Imaging Digital R/F remote controlled table radiology ahead the evolution of the digital remote controlled table Apollo DRF is Villa s reference product in the panorama of digital remote controlled

More information

VATECH IMAGING SYSTEMS

VATECH IMAGING SYSTEMS VATECH IMAGING SYSTEMS 2 About Vatech America 3 Vatech Assurance 4 PaX-i 5 PaX-i Insight 10 i3d Smart 14 i3d Smart 8x8 18 Green CT 22 Green CT 2 27 i3d Premium 31 Ez3D-i 35 EzDent-i 38 EzRay Air Wall 39

More information

Colorado School of Mines. Computer Vision. Professor William Hoff Dept of Electrical Engineering &Computer Science.

Colorado School of Mines. Computer Vision. Professor William Hoff Dept of Electrical Engineering &Computer Science. Professor William Hoff Dept of Electrical Engineering &Computer Science http://inside.mines.edu/~whoff/ 1 Sensors and Image Formation Imaging sensors and models of image formation Coordinate systems Digital

More information

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC R. Bellazzini a,b, G. Spandre a*, A. Brez a, M. Minuti a, M. Pinchera a and P. Mozzo b a INFN Pisa

More information

Breast Tomosynthesis. Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School

Breast Tomosynthesis. Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School Breast Tomosynthesis Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School Outline Physics aspects of breast tomosynthesis Quality control of breast tomosynthesis

More information

TESTING FLAT-PANEL IMAGING SYSTEMS: What the Medical Physicist Needs to Know. JAMES A. TOMLINSON, M.S., D.A.B.R. Diagnostic Radiological Physicist

TESTING FLAT-PANEL IMAGING SYSTEMS: What the Medical Physicist Needs to Know. JAMES A. TOMLINSON, M.S., D.A.B.R. Diagnostic Radiological Physicist TESTING FLAT-PANEL IMAGING SYSTEMS: What the Medical Physicist Needs to Know JAMES A. TOMLINSON, M.S., D.A.B.R. Diagnostic Radiological Physicist Topics Image Uniformity and Artifacts Image Quality - Detail

More information

Digital radiography. bucky table and wall stand as a dual detector or wireless system. Amadeo DR Systems

Digital radiography. bucky table and wall stand as a dual detector or wireless system. Amadeo DR Systems Amadeo DR Systems with dicom PACS DX-R Software X-ray Systems for the Future Digital radiography with Amadeo R-DR including bucky table and wall stand as a dual detector or wireless system High contrast

More information

The DR system in a suitcase for mobile X-ray

The DR system in a suitcase for mobile X-ray Leonardo DR 1417 The DR system in a suitcase for mobile X-ray total weight only ca. 22kg The portable DR system for mobile X-ray OR Technology Digital X-ray and Imaging Solutions OR Technology has been

More information

Mammography: Physics of Imaging

Mammography: Physics of Imaging Mammography: Physics of Imaging Robert G. Gould, Sc.D. Professor and Vice Chair Department of Radiology and Biomedical Imaging University of California San Francisco, California Mammographic Imaging: Uniqueness

More information

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development Teaching Radiographic Technique in a Digital Imaging Paradigm Objectives 1. Discuss the historical development of digital imaging. Dawn Couch Moore, M.M.Sc., RT(R) Assistant Professor and Director Emory

More information

RaySafe X2. Effortless measurements of X-ray

RaySafe X2. Effortless measurements of X-ray RaySafe X2 Effortless measurements of X-ray At your fingertips We ve grown accustomed to intuitive interactions with our devices. After all, it s not the device that s most important, but what you can

More information

DV420 SPECTROSCOPY. issue 2 rev 1 page 1 of 5m. associated with LN2

DV420 SPECTROSCOPY.   issue 2 rev 1 page 1 of 5m. associated with LN2 SPECTROSCOPY Andor s DV420 CCD cameras offer the best price/performance for a wide range of spectroscopy applications. The 1024 x 256 array with 26µm 2 pixels offers the best dynamic range versus resolution.

More information

SAMSUNG SMART DIGITAL RADIOGRAPHY. XGEO GU60A series REDEFINING ERGONOMICS

SAMSUNG SMART DIGITAL RADIOGRAPHY. XGEO GU60A series REDEFINING ERGONOMICS SAMSUNG SMART DIGITAL RADIOGRAPHY XGEO GU60A series REDEFINING ERGONOMICS U-arm Positioner (Fully Automated) The XGEO GU60A/60A-65 is a universal, fully motorized system. Its unique U-arm rotates +120

More information

Test Equipment for Radiology and CT Quality Control Contents

Test Equipment for Radiology and CT Quality Control Contents Test Equipment for Radiology and CT Quality Control Contents Quality Control Testing...2 Photometers for Digital Clinical Display QC...3 Primary Workstations...3 Secondary Workstations...3 Testing of workstations...3

More information

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA EDWARD L. NICKOLOFF DEPARTMENT OF RADIOLOGY COLUMBIA UNIVERSITY NEW YORK, NY ACCEPTANCE TESTING GOALS PRIOR TO 1st CLINICAL USAGE

More information

Ray Detection Digital Image Quality and Influential Factors

Ray Detection Digital Image Quality and Influential Factors 7th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Ray Detection Digital Image Quality and Influential Factors Xiangzhao ZENG (Qingyuan, Guangdong, China Guangdong Yingquan

More information

Amorphous Selenium Direct Radiography for Industrial Imaging

Amorphous Selenium Direct Radiography for Industrial Imaging DGZfP Proceedings BB 67-CD Paper 22 Computerized Tomography for Industrial Applications and Image Processing in Radiology March 15-17, 1999, Berlin, Germany Amorphous Selenium Direct Radiography for Industrial

More information

Digital Radiography using High Dynamic Range Technique

Digital Radiography using High Dynamic Range Technique Digital Radiography using High Dynamic Range Technique DAN CIURESCU 1, SORIN BARABAS 2, LIVIA SANGEORZAN 3, LIGIA NEICA 1 1 Department of Medicine, 2 Department of Materials Science, 3 Department of Computer

More information

Dosepix Detector as kvp-meter in Radiology and Mammography: First steps

Dosepix Detector as kvp-meter in Radiology and Mammography: First steps Dosepix Detector as kvp-meter in Radiology and Mammography: First steps F.Bisello, I.Ritter, F.Tennert, A.Zang MediPix Collaboration Meeting, 19th February 2014, CERN Protect, Enhance, and Save Lives -

More information

X-RAYS - NO UNAUTHORISED ENTRY

X-RAYS - NO UNAUTHORISED ENTRY Licencing of premises Premises Refer Guidelines A radiation warning sign and warning notice, X-RAYS - NO UNAUTHORISED ENTRY must be displayed at all entrances leading to the rooms where x-ray units are

More information

VATECH IMAGING SYSTEMS

VATECH IMAGING SYSTEMS VATECH IMAGING SYSTEMS About Vatech America Vatech Assurance PaX-i PaX-i Insight i3d Smart Green CT Green CT 2 i3d Premium Ez3D-i EzDent-i EzRay Air Wall HD Sensor 3 4 5 10 14 18 23 27 31 34 35 38 2 Contents

More information

LOW DOSE X-RAY DETECTORS for Dental Applications

LOW DOSE X-RAY DETECTORS for Dental Applications IMAGE SENSORS X-RAY DETECTORS IMAGE PROCESSING CUSTOM SOLUTIONS LOW DOSE X-RAY DETECTORS for Dental Applications COMMITTED TO PEOPLE. DRIVEN BY INNOVATION. IMAGE SENSORS X-RAY DETECTORS IMAGE PROCESSING

More information

TEP Optimization of the CT scan quality. Related topics Number of projections, stop angle, exposure time, image statistics, binning

TEP Optimization of the CT scan quality. Related topics Number of projections, stop angle, exposure time, image statistics, binning Optimization of the CT scan quality TEP Related topics Number of projections, stop angle, exposure time, image statistics, binning Principle The quality of the image will improve with a number of parameters.

More information

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images. DIGITAL RADIOGRAPHY Digital radiography is a film-less technology used to record radiographic images. 1 The purpose of digital imaging is to generate images that can be used in the diagnosis and assessment

More information

Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities

Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities Journal of Physics: Conference Series PAPER OPEN ACCESS Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities Recent citations - Resolution Properties of a

More information

Beam-Restricting Devices

Beam-Restricting Devices Beam-Restricting Devices Three factors contribute to an increase in scatter radiation: Increased kvp Increased Field Size Increased Patient or Body Part Size. X-ray Interactions a some interact with the

More information

VistaScan Combi View - efficiency without compromise

VistaScan Combi View - efficiency without compromise VistaScan Combi View - efficiency without compromise The image plate scanner with a touchscreen for all formats COMPRESSED AIR SUCTION IMAGING DENTAL CARE HYGIENE Image plate technology - a With the versatile

More information

CMOS X-RAY DETECTORS. for Industrial Non-Destructive Testing COMMITTED TO PEOPLE. DRIVEN BY INNOVATION.

CMOS X-RAY DETECTORS. for Industrial Non-Destructive Testing COMMITTED TO PEOPLE. DRIVEN BY INNOVATION. IMAGE SENSORS X-RAY DETECTORS IMAGE PROCESSING CUSTOM SOLUTIONS CMOS X-RAY DETECTORS for Industrial Non-Destructive Testing COMMITTED TO PEOPLE. DRIVEN BY INNOVATION. IMAGE SENSORS X-RAY DETECTORS IMAGE

More information

Chapter 2-Digital Components

Chapter 2-Digital Components Chapter 2-Digital Components What Makes Digital Cameras Work? This is how the D-SLR (Digital Single Lens Reflex) Camera works. The sensor This is the light sensitive part of your camera There are two basic

More information

CXDI-70C WIRELESS SPECIFICATIONS

CXDI-70C WIRELESS SPECIFICATIONS CXDI-70C WIRELESS SPECIFICATIONS Purpose Method Sensor Scintillator Pixel Pitch Pixels Image Size A/D Grayscale Wireless Standard Preview Image Access Time High Resolution Image Display Time Cycle Time

More information

Investigation of Effective DQE (edqe) parameters for a flat panel detector

Investigation of Effective DQE (edqe) parameters for a flat panel detector Investigation of Effective DQE (edqe) parameters for a flat panel detector Poster No.: C-1892 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Exhibit D. Bor 1, S. Cubukcu 1, A. Yalcin 1, O.

More information

Dental Radiography. One of the problems of dental radiography is having different dimensions than normal.

Dental Radiography. One of the problems of dental radiography is having different dimensions than normal. The prototype receptor (the recording medium) most commonly used in dental radiography is the radiographic film. However, there are many other new more efficient receptors than the formed one that can

More information

Large-Area CdTe Photon-Counting Pixel Detectors

Large-Area CdTe Photon-Counting Pixel Detectors Large-Area CdTe Photon-Counting Pixel Detectors Tilman Donath, Application Scientist 22.6.2015, DIR2015, Ghent DECTRIS Ltd. 5400 Baden Switzerland www.dectris.com Agenda 1. Introduction Hybrid Photon Counting

More information

VistaScan Plus Image Plate Scanners The most comprehensive dental scanners

VistaScan Plus Image Plate Scanners The most comprehensive dental scanners VistaScan Plus Image Plate Scanners The most comprehensive dental scanners COMPRESSED AIR SUCTION IMAGING DENTAL CARE HYGIENE Make your surgery routines more efficient Intraoral and extraoral images in

More information

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

Digital Radiographic Inspection replacing traditional RT and 3D RT Development Digital Radiographic Inspection replacing traditional RT and 3D RT Development Iploca Novel Construction Meeting 27&28 March 2014 Geneva By Jan van der Ent Technical Authority International Contents Introduction

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Size 1 External dimensions...25 x 39mm Active surface area...600mm2 (20 x 30mm) Number of pixels...1.50million SOPIX inside system Technology...CMOS + scintillator+ optic fibre

More information

Photographic Exposure Colin Legg

Photographic Exposure Colin Legg Why does Auto sometimes get it wrong? Photographic Exposure Colin Legg Correct exposure is subjective judgement Predominantly white subject camera will tend to under-expose Predominantly dark subject camera

More information

Exposure in Dental Radiology: A Comparison Between Intra-oral, Panoramic and Tomographic Examinations

Exposure in Dental Radiology: A Comparison Between Intra-oral, Panoramic and Tomographic Examinations Exposure in Dental Radiology: A Comparison Between Intra-oral, Panoramic and Tomographic Examinations S. Baechler 1, P. Monnin 1, A. Aroua 1, J.F. Valley 1, M. Perrier, P. Trueb 3, F.R. Verdun 1 1 University

More information

The intraoral X-ray family. dentsplysirona.com

The intraoral X-ray family. dentsplysirona.com The intraoral X-ray family dentsplysirona.com 02 I 03 Dentists trust in Dentsply Sirona Imaging systems by Dentsply Sirona are the epitome of quality and supreme diagnostics, providing an array of options

More information

NEWTOM GO 2D GREAT.VISION

NEWTOM GO 2D GREAT.VISION CEFLA s.c. Via Selice Provinciale 23/a 40026 Imola Italy t. +39 045 8202727 045 583500 info@newtom.it newtom.it 05/2018 NGO2GB181S00 According to the standards in force, in extra-eu areas the availability

More information

Introduction. Chapter 1

Introduction. Chapter 1 1 Chapter 1 Introduction During the last decade, imaging with semiconductor devices has been continuously replacing conventional photography in many areas. Among all the image sensors, the charge-coupled-device

More information

TEP Principles of Digital X-ray Imaging

TEP Principles of Digital X-ray Imaging Related topics exposure time, detector saturation, full well capacity, detector calibration, beam intensity, detector offset, pixel specific gain, attenuation and transmission, image processing. Principle

More information

High Energy Digital Radiography & 3D-CT for Industrial Systems

High Energy Digital Radiography & 3D-CT for Industrial Systems DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France High Energy Digital Radiography & 3D-CT for Industrial Systems Non-Destructive

More information

Digital Cameras vs Film: the Collapse of Film Photography Can Your Digital Camera reach Film Photography Performance? Film photography started in

Digital Cameras vs Film: the Collapse of Film Photography Can Your Digital Camera reach Film Photography Performance? Film photography started in Digital Cameras vs Film: the Collapse of Film Photography Can Your Digital Camera reach Film Photography Performance? Film photography started in early 1800 s almost 200 years Commercial Digital Cameras

More information

Last class. This class. CCDs Fancy CCDs. Camera specs scmos

Last class. This class. CCDs Fancy CCDs. Camera specs scmos CCDs and scmos Last class CCDs Fancy CCDs This class Camera specs scmos Fancy CCD cameras: -Back thinned -> higher QE -Unexposed chip -> frame transfer -Electron multiplying -> higher SNR -Fancy ADC ->

More information

Improving the Collection Efficiency of Raman Scattering

Improving the Collection Efficiency of Raman Scattering PERFORMANCE Unparalleled signal-to-noise ratio with diffraction-limited spectral and imaging resolution Deep-cooled CCD with excelon sensor technology Aberration-free optical design for uniform high resolution

More information

Simplifying Digital X-RAY FOR Chiropractic DIGITAL X-RAY RETROFIT COMPLETE DIGITAL X-RAY ACQUISITION & IMAGE MANAGEMENT

Simplifying Digital X-RAY FOR Chiropractic DIGITAL X-RAY RETROFIT COMPLETE DIGITAL X-RAY ACQUISITION & IMAGE MANAGEMENT Simplifying Digital X-RAY FOR Chiropractic DIGITAL X-RAY RETROFIT COMPLETE DIGITAL X-RAY ACQUISITION & IMAGE MANAGEMENT Fusion dr uniqueness The difference between fusion and all the others UNLIKE ALL

More information

Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation

Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation Beam hardening and metal artefacts TEP Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation Principle X-ray sources produce a polychromatic spectrum

More information

Digital Cameras vs Film: the Collapse of Film Photography Can Your Digital Camera reach Film Photography Performance? Film photography started in

Digital Cameras vs Film: the Collapse of Film Photography Can Your Digital Camera reach Film Photography Performance? Film photography started in Digital Cameras vs Film: the Collapse of Film Photography Can Your Digital Camera reach Film Photography Performance? Film photography started in early 1800 s almost 200 years Commercial Digital Cameras

More information

AeroDR X60. Motorized X-ray System

AeroDR X60. Motorized X-ray System AeroDR X60 Motorized X-ray System AeroDR X60 2 MOTORIZED X-RAY SYSTEM The AeroDR X60 is a high quality, cost effective, compact motorized floor mounted X-ray system, built around Konica Minolta s renowned

More information

User Manual. FlashRay Sensor. 100 E. Granada Blvd. Suite 219 Ormond Beach, FL Ph: Manual Date pg.

User Manual. FlashRay Sensor. 100 E. Granada Blvd. Suite 219 Ormond Beach, FL Ph: Manual Date pg. User Manual FlashRay Sensor 100 E. Granada Blvd. Suite 219 Ormond Beach, FL 32176 Ph: 386-672-0450 800-323-2690 Manual Date 20181010 pg. 1 Table of Contents 1 Introduction... 4 1.1 Indication for Use...

More information

Digital Dental Quality Assurance Manual Initial Baseline and Longitudinal Assessment

Digital Dental Quality Assurance Manual Initial Baseline and Longitudinal Assessment Digital Dental Quality Assurance Manual Initial Baseline and Longitudinal Assessment Initial Baseline Assessment 1. Place the detector to be evaluated directly under the central portion of the Digital

More information

NOT FOR DISTRIBUTION JINST_128P_1010 v2

NOT FOR DISTRIBUTION JINST_128P_1010 v2 Pixel sensitivity variations in a CdTe-Medipix2 detector using poly-energetic x-rays R Aamir a, S P Lansley a, b,*, R Zainon a, M Fiederle c, A. Fauler c, D. Greiffenberg c, P H Butler a, d d, e, f, A

More information

Phase Contrast Imaging with X-ray tube

Phase Contrast Imaging with X-ray tube Phase Contrast Imaging with X-ray tube Institute for Roentgen Optics /IRO/, Moscow Vladimir Shovkun and Muradin Kumakhov Proc. SPIE v.5943, 2005 Institute for Roentgen Optics. Vladimir Ya. Shovkun. E-mail:

More information

2012 :15th SESSION of ESMP

2012 :15th SESSION of ESMP 2012 :15th SESSION of ESMP Lecture presented in Archamps (Salève Building) by : Elly CASTELLANO (London) Patient dosimetry in x-ray imaging and CT Elly Castellano Objectives measurable dose quantities

More information

Applied Sciences at Winterthur)

Applied Sciences at Winterthur) Comparison of image quality between a digital panorama X-ray unit with a CdTe-CMOS detector and panorama X- ray units with other types of digital detectors Stephan Scheidegger 1 1 Zürcher Hochschule für

More information

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE A. Miceli ab, R. Thierry a, A. Flisch a, U. Sennhauser a, F. Casali b a Empa - Swiss Federal Laboratories for

More information

BASICS OF FLUOROSCOPY

BASICS OF FLUOROSCOPY Medical Physics Residents Training Program BASICS OF FLUOROSCOPY Dr. Khalid Alyousef, PhD Department of Medical Imaging King Abdulaziz Medical City- Riyadh Edison examining the hand of Clarence Dally with

More information

Welcome to the smiling world of SOREDEX CRANEX. Novus e. Easy as a breeze. soredex.com

Welcome to the smiling world of SOREDEX CRANEX. Novus e. Easy as a breeze. soredex.com Welcome to the smiling world of SOREDEX CRANEX Novus e Easy as a breeze soredex.com Benefits at a glance Essential part of your daily patient care Excellent Fast scanning times are convenient for the patient

More information

FMT18 FLOOR MOUNTED SYSTEM

FMT18 FLOOR MOUNTED SYSTEM mas Time AEC 320 kvp 64 mas 320 ma 320 ma 320 DEN 0.0 mm Cu 17 in X 17 in 72.0 in FMT18 FLOOR MOUNTED SYSTEM with Synchronized Tracking System Overview Clinical Efficiency The FMT18 System was designed

More information

Dental Line. Digital Panoramic System. radiology ahead

Dental Line. Digital Panoramic System. radiology ahead Dental Line Digital Panoramic System radiology ahead next generation digital panoramic unit Cutting-edge technology and design Rotograph Prime is the first in a new generation of digital panoramic units,

More information

Digital Radiography for the Inspection of Small Defects

Digital Radiography for the Inspection of Small Defects ECNDT 2006 - Th.3.2.3 Digital Radiography for the Inspection of Small Defects Bruce Blakeley, TWI, Cambridge, UK Konstantinos Spartiotis, Ajat, Espoo, Finland Abstract. Digital Radiography offers several

More information

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893 Digital Radiography D. J. Hall, Ph.D. x20893 djhall@ucsd.edu Background Common Digital Modalities Digital Chest Radiograph - 4096 x 4096 x 12 bit CT - 512 x 512 x 12 bit SPECT - 128 x 128 x 8 bit MRI -

More information

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image Introduction Chapter 16 Diagnostic Radiology Radiation Dosimetry I Text: H.E Johns and J.R. Cunningham, The physics of radiology, 4 th ed. http://www.utoledo.edu/med/depts/radther In diagnostic radiology

More information

Version 1.0. TechnicVR. Student Guide

Version 1.0. TechnicVR. Student Guide Version 1.0 TechnicVR s h a d e r w a r e. c o m Student Guide TechnicVR s h a d e r w a r e. c o m Student Guide shaderware 2008 PO Box 103 Saltburn Cleveland TS12 1WP w w w. s h a d e r w a r e. c o

More information