(Geant4) Monte Carlo benchmarking. Harald Paganetti
|
|
- Clara Page
- 6 years ago
- Views:
Transcription
1 (Geant4) Monte Carlo benchmarking Harald Paganetti
2 Why benchmarking? 1. We are in Medical Physics! 2. Monte Carlo is considered to be the gold standard 3. There are various competing codes/algorithms 4. We want confidence in our code
3 Types of Monte Carlo benchmarking A Benchmarking based on basic data B Benchmarking based on complex data
4 Types of Monte Carlo benchmarking A Benchmarking based on basic data Benchmarking done by developers (and users)
5 Types of Monte Carlo benchmarking A Benchmarking based on basic data cross section data need to be accessible (MCNPX?)
6 Types of Monte Carlo benchmarking A Benchmarking based on basic data B Benchmarking based on complex data Benchmarking done by users only (!) We can all contribute (e.g., Poon, Paganetti)
7
8
9 Types of Monte Carlo benchmarking A Benchmarking based on basic data Often not sufficient! B Benchmarking based on complex data Often too user specific!
10 Types of Monte Carlo benchmarking A Benchmarking based on basic data B Benchmarking based on standard ( complex ) data Standard benchmarking problems should be simple (used by multiple users in various codes; easy error analysis)
11 Multi-Layer Faraday Cup (MLFC) Clean benchmark for nuclear models: p+ 80 % separated nuclear buildup region device has 100% acceptance for charged secondaries technique measures charge, not dose (no problems of dosimeter linearity and response to particle types) p+ p+.. charge A B C Cu Cu Cu e.g., (p,pn) charge : 0 (+p; -recoil) 1 (+p) p+.. n
12 7.6 cm x 7.6 cm
13 Multi-Layer Faraday Cup (MLFC) can be used for high and low-z! A B p+ p+ e.g., (p,pn) charge :.. p+ CH 2 CH 2 CH 2.. n charge 0 (+p -recoil) 1 (+p) A B C p+ p+.. Cu Cu Cu.. n e.g., (p,pn) charge : 0 (+p; -recoil) 1 (+p)
14
15 Types of Monte Carlo benchmarking A Benchmarking based on basic data B Benchmarking based on standard complex data We need standard benchmarking problems
16 The Computational Medical Physics Working Group (CMPWG) is an international group dedicated to the pursuit of better computational tools in medical and health physics applications. CMPWG consists of individuals from the American Nuclear Society (ANS), American Association of Physicists in Medicine (AAPM), Society of Nuclear Medicine (SNM), Health Physics Society (HPS) among others. CMPWG is hosted by two divisions within the American Nuclear Society. Mathematics and Computations Division (MCD) Biology and Medicine Upcoming Conferences April ANS RPSD Carlsbad, New Mexico June ANS Annual Meeting - Reno, Nevada July AAPM 48th Annual Meeting - Orlando, Florida October First European Workshop on Monte Carlo Treatment Pla
17 Benchmarks Contribute a benchmark problem Submitted problems Radiation Therapy Brachytherapy External Beam Therapy Proton Therapy Imaging Nuclear Medicine Health Physics Too complex!
18 Submit only successful simulations to CMPWG and report unsuccessful ones to Geant4-developers!
19 Discussion: We should compare cross section data used by various codes WHO? We need to design a set of (simple) benchmarking problems WHO?
Not only web. Computing methods and tools originating from high energy physics experiments
Not only web Computing methods and tools originating from high energy physics experiments Oxana Smirnova Particle Physics (www.hep.lu.se) COMPUTE kick-off, 2012-03-02 High Energies start here Science of
More informationFuture Perspectives. Maria Grazia Pia, INFN Genova in rappresentanza del gruppo Geant4-INFN.
Future Perspectives in rappresentanza del gruppo Geant4-INFN http://www.ge.infn.it/geant4/ Commissione Calcolo e Reti Roma, 21-22 febbraio 2005 Geant4: the present BaBar 2.2 billion events, 700 years,
More informationCalibration of KAP meters
Calibration of KAP meters Alexandr Malusek! Division of Radiological Sciences Department of Medical and Health Sciences Linköping University! 2014-04-15 1 Outline 1. KAP meter construction 2. Air kerma-area
More informationMonte Carlo Verification and Modeling of Lead- Bismuth Spallation Targets
Reactor Campaign (TRP) Transmutation Research Program Projects 1-2003 Monte Carlo Verification and Modeling of Lead- Bismuth Spallation Targets Daniel R. Lowe University of Nevada, Las Vegas Follow this
More informationescience/lhc-expts integrated t infrastructure
escience/lhc-expts integrated t infrastructure t 16 Oct. 2008 Partner; H F Hoffmann, CERN Jürgen Knobloch/CERN Slide 1 1 e-libraries Archives/Curation centres Large Data Repositories Facilities, Instruments
More informationSRS MapCHECK. SRS Patient QA, No Film. Your Most Valuable QA and Dosimetry Tools
SRS MapCHECK SRS Patient QA, No Film Your Most Valuable QA and Dosimetry Tools SRS Patient QA, No Film With improvements in targeting and localization, stereotactic treatments have become prevalent. To
More informationA novel and fast method for proton range verification using a step wedge and 2D scintillator
A novel and fast method for proton range verification using a step wedge and 2D scintillator Jiajian Shen, a) Bryce C. Allred, Daniel G. Robertson, Wei Liu, and Terence T. Sio Department of Radiation Oncology,
More informationA Generalized Strategy for 3D Dose Verification of IMRT/VMAT Using EPID-measured Transit Images
A Generalized Strategy for 3D Dose Verification of IMRT/VMAT Using EPID-measured Transit Images Aiping Ding, Bin Han, Lei Wang, Lei Xing Department of Radiation Oncology, Stanford University School of
More information200 MHz 350 MHz 750 MHz Linac2 RFQ2 202 MHz 0.5 MeV /m Weight : 1000 kg/m Ext. diameter : 45 cm
M. Vretenar, CERN for the HF-RFQ Working Group (V.A. Dimov, M. Garlasché, A. Grudiev, B. Koubek, A.M. Lombardi, S. Mathot, D. Mazur, E. Montesinos, M. Timmins, M. Vretenar) 1 1988-92 Linac2 RFQ2 202 MHz
More informationProduct Range Electronic Units
Pyramid Technical Consultants, Inc. 1050 Waltham Street Suite 200 Lexington, MA 02421 TEL: +1 781 402-1700 TEL (UK): +44 1273 492001 FAX: (781) 402-1750 EMAIL: SUPPORT@PTCUSA.COM Product Range Electronic
More informationDiagnostic X-Ray Shielding
Diagnostic X-Ray Shielding Multi-Slice CT Scanners Using NCRP 147 Methodology Melissa C. Martin, M.S., FAAPM, FACR Therapy Physics Inc., Bellflower, CA AAPM Annual Meeting, Orlando, FL FL Refresher Course
More informationOptimization of Energy Modulation Filter for Dual Energy CBCT Using Geant4 Monte-Carlo Simulation
Original Article PROGRESS in MEDICAL PHYSICS 27(3), Sept. 2016 http://dx.doi.org/10.14316/pmp.2016.27.3.125 pissn 2508-4445, eissn 2508-4453 Optimization of Energy Modulation Filter for Dual Energy CBCT
More informationMC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE
MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE A. Miceli ab, R. Thierry a, A. Flisch a, U. Sennhauser a, F. Casali b a Empa - Swiss Federal Laboratories for
More informationCommissioning and Calibrating a Linear Accelerator State-of-the-Art in 2010
Commissioning and Calibrating a Linear Accelerator State-of-the-Art in 2010 Indra J. Das, PhD, FACR Department of Radiation Oncology Indiana University of School of Medicine & Midwest Proton Radiation
More informationCylindrical Ion Chambers Victoreen Model 550 Series
Cylindrical Ion Chambers Victoreen Model 550 Series! Cylindrical Ion Chambers for use with Model 35040 and Model 530 electrometers! Wide range of applications in Diagnostic X-Ray and Radiation Oncology
More informationThe SIRAD irradiation facility at the INFN - Legnaro National Laboratory
The SIRAD irradiation facility at the INFN - Legnaro National Laboratory I. Introduction 2 The INFN - Legnaro National Laboratory (LNL) SIRAD beamline http://www.lnl.infn.it 3 What is SIRAD? SIRAD is the
More informationArcCHECK, ein neuartiger QS-Ansatz bei der Rotationsbestrahlung
ArcCHECK, ein neuartiger QS-Ansatz bei der Rotationsbestrahlung Treffen des Arbeitskreises IMRT der DGMP Würzburg, 26 + 27.03.2009 Salih Arican Sun Nuclear Corporation QA Challenge for Rotational Beams
More informationEvaluation of STPA in the Safety Analysis of the Gantry 2 Proton Radiation Therapy System Martin Rejzek, Paul Scherrer Institute, Switzerland
Evaluation of STPA in the Safety Analysis of the Gantry 2 Proton Radiation Therapy System Martin Rejzek, Paul Scherrer Institute, Switzerland 11.04.2012 STAMP/STPA Workshop - Massachusetts Institute of
More informationEvaluation of dosimetry parameters of photons and electron beams using a linear ionization chamber array
Evaluation of dosimetry parameters of photons and electron beams using a linear ionization chamber array José A. Bencomo, * Geoffrey Ibbott, Seungsoo Lee, and Joao A. Borges Department of Radiation Physics.
More informationMonte Carlo study on a new concept of a scanning photon beam system for IMRT
NUKLEONIKA 2011;56(4):291 297 ORIGINAL PAPER Monte Carlo study on a new concept of a scanning photon beam system for IMRT Anna M. Wysocka-Rabin, Günter H. Hartmann Abstract. Intensity-modulated radiation
More informationCylindrical Ion Chambers
Cylindrical Ion Chambers Radiation Oncology ON Victoreen Model 550T Series Cylindrical Ion Chambers for use with Model 35040 and Model 560 electrometers Wide range of applications in Diagnostic X-Ray and
More informationA Multichannel Dosimeter Based on Scintillating Fibers for Medical Applications
A Multichannel Dosimeter Based on Scintillating Fibers for Medical Applications K.-H. Becks 1, J. Drees 1, K. Goldmann 1, I.M. Gregor 1 2, M. Heintz, Arndt Roeser* 1 Fachbereich Physik, Bergische Universität-Gesamthochschule
More informationA new approach to measure dwell position inaccuracy in HDR ring applicators quantification and corrective QA
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 12, NUMBER 1, WINTER 2010 A new approach to measure dwell position inaccuracy in HDR ring applicators quantification and corrective QA Abdul Qadir Jangda,
More informationA Fast Monolithic System for Proton Imaging. Fritz DeJongh ProtonVDA Inc October 2017
A Fast Monolithic System for Proton Imaging Fritz DeJongh ProtonVDA Inc October 2017 Disclosures I am a cofounder and co-owner of ProtonVDA Inc We hold intellectual property rights on our proton imaging
More informationX3D in Radiation Therapy Procedure Planning. Felix G. Hamza-Lup, Ph.D. Computer Science Armstrong Atlantic State University Savannah, Georgia USA
X3D in Radiation Therapy Procedure Planning Felix G. Hamza-Lup, Ph.D. Computer Science Armstrong Atlantic State University Savannah, Georgia USA Outline 1. What is radiation therapy? 2. Treatment planning
More informationMuon detection in security applications and monolithic active pixel sensors
Muon detection in security applications and monolithic active pixel sensors Tracking in particle physics Gaseous detectors Silicon strips Silicon pixels Monolithic active pixel sensors Cosmic Muon tomography
More informationA feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer *
IOP PUBLISHING Phys. Med. Biol. 52 (7) 2147 2156 PHYSICS IN MEDICINE AND BIOLOGY doi:1.188/31-9155/52/8/7 A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate
More informationSCINTILLATION FIBER DETECTOR FOR DOSE VERIFICATION IN PROTON THERAPY
SCINTILLATION FIBER DETECTOR FOR DOSE VERIFICATION IN PROTON THERAPY Suhyun Lee Nuclear Physics Lab. Korea University CONTENTS Introduction Detector - Scintillation-fiber array - Electronics Beam Test
More informationSIMULATION OF A SIGNAL IN THE BEAM LOSS
RADIATION ASPECTS OF LHC SIMULATION OF A SIGNAL IN THE BEAM LOSS MONITORS OF THE MOMENTUM CLEANING INSERTION FOR THE NEW COLLIMATOR JAWS DESIGN IHEP, Protvino, Russia Summary of the presentation Page 1
More informationApplication of the HICAM Camera for Imaging of Prompt Gamma Rays in Measurements of Proton Beam Range
Application of the HICAM Camera for Imaging of Prompt Gamma Rays in Measurements of Proton Beam Range R. Peloso 1, P. Busca 1, A.Celani 2, C. Fiorini 1, I.Perali 1, M. Basilavecchia 2, T. Frizzi 2, J.
More informationWide beam CT dosimetry. Elly Castellano
Wide beam CT dosimetry Elly Castellano Outline revision: CT dose indices wide-beam CT: the end of the road for CTDI? the IEC rescue plan for CTDI 100 the american way AAPM report 111 better estimates of
More informationComparison of peripheral dose measurements using Ionization chamber and MOSFET detector
ORIGINAL ARTICLES Comparison of peripheral dose measurements using Ionization chamber and MOSFET detector Gopiraj ANNAMALAI 1, Ramasubramanian VELAYUDHAM 2 ABSTRACT Received: 7.07.2009 Accepted: 2.11.2009
More informationEnergy Monitoring Device for Electron Beam Facilities
1 SM/EB-18 Energy Monitoring Device for Electron Beam Facilities M. Lavalle 1, P.G. Fuochi 1, A. Martelli 1, U. Corda 1, A. Kovács 2, K. Mehta 3, F. Kuntz 4, S. Plumeri 4 1 CNR-ISOF, Via P. Gobetti 101,
More informationGas Electron Multiplier Detectors
Muon Tomography with compact Gas Electron Multiplier Detectors Dec. Sci. Muon Summit - April 22, 2010 Marcus Hohlmann, P.I. Florida Institute of Technology, Melbourne, FL 4/22/2010 M. Hohlmann, Florida
More informationDevelopment of Personal Dosimeter Using Electronic Dose Conversion Method
Proceedings of the Korean Nuclear Spring Meeting Gyeong ju, Korea, May 2003 Development of Personal Dosimeter Using Electronic Dose Conversion Method Wanno Lee, Bong Jae Lee, and Chang Woo Lee Korea Atomic
More informationEvaluation of a diode array for QA measurements on a helical tomotherapy unit
Evaluation of a diode array for QA measurements on a helical tomotherapy unit K. M. Langen, a S. L. Meeks, D. O. Poole, T. H. Wagner, T. R. Willoughby, O. A. Zeidan, and P. A. Kupelian Department of Radiation
More informationConsultation for the Formulation of the NMS IR Programme Dr Dave Rayner Formulator Business Leader, Radiation Dosimetry
Consultation for the Formulation of the NMS IR Programme 2007-10 Dr Dave Rayner Formulator Business Leader, Radiation Dosimetry 31 May 2006 The Timetable 24 May Orientation with MAC WG 5 Jun NPL staff
More informationGamma emission tomography of nuclear fuel; Objectives and status of the IAEA UGET project.
Gamma emission tomography of nuclear fuel; Objectives and status of the IAEA UGET project. Peter Jansson Staffan Jacobsson Svärd Sophie Grape Div. of Applied Nuclear Physics Dept. of Physics and Astronomy
More informationEstimation of signal transfer property for wireless digital detector in different measurement schemes
Estimation of signal transfer property for wireless digital detector in different measurement schemes Anatoli Vladimirov, Kalle Kepler Training Centre of Medical Physics, University of Tartu, Estonia 11
More informationAssessment of an Unshielded Electron Field Diode Dosimeter for Beam Scanning in Small- to Medium-Sized 6 MV Photon Fields
Iranian Journal of Medical Physics Vol. 10, No. 1-2, Winter & Spring 2013, 51-57 Received: November 22, 2012; Accepted: March 12, 2013 Original Article Assessment of an Unshielded Electron Field Diode
More informationTest of a Multilayer Dose-Verification Gaseous Detector with Raster Scan Mode Proton Beams
Test of a Multilayer Dose-Verification Gaseous Detector with Raster Scan Mode Proton Beams Kyong Sei Lee*, Byungsik Hong, Minho Kang, Seunkyung Lee, and Sung Keun Park Korea University, Seoul 136-713 Sung
More informationJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 5, 2015
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 5, 15 Evaluation of monitor unit calculation based on measurement and calculation with a simplified Monte Carlo method for passive beam delivery
More informationVISUAL INSPECTION OF A COPPER COLLIMATOR IRRADIATED BY 590 MeV PROTONS AT PSI
VISUAL INSPECTION OF A COPPER COLLIMATOR IRRADIATED BY 590 MeV PROTONS AT PSI Å Strinning*, P. Baumann, M. Gandel, D. Kiselev, Y.J. Lee, S. Adam, Paul Scherrer Institut,5232 Villigen PSI, Switzerland Abstract
More informationInternational Journal of Advance Engineering and Research Development
Scientific Journal of Impact Factor (SJIF): 5.71 International Journal of Advance Engineering and Research Development Volume 5, Issue 06, June -2018 e-issn (O): 2348-4470 p-issn (P): 2348-6406 STUDY OF
More informationInitial Certification
Initial Certification Nuclear Medical Physics (NMP) Study Guide Part 2 Content Guide and Sample Questions The content of all ABR exams is determined by a panel of experts who select the items based on
More informationTest Equipment for Radiology and CT Quality Control Contents
Test Equipment for Radiology and CT Quality Control Contents Quality Control Testing...2 Photometers for Digital Clinical Display QC...3 Primary Workstations...3 Secondary Workstations...3 Testing of workstations...3
More informationThe LUX Experiment - Background Model and Physics Goals. D. Malling April APS, Denver, CO
The X Experiment - Background Model and Physics Goals D. Malling April APS, Denver, CO 2013-04-13 X Background Goals Background goal:
More informationdiagnostic examination
RADIOLOGICAL PHYSICS 2011 Raphex diagnostic examination Adel A. Mustafa, Ph.D., Editor PUBLISHED FOR: RAMPS (Radiological and Medical Physics Society of New York) preface The RAPHEX Diagnostic exam 2011
More informationPrompt-Gamma Based Range Verification in Particle Therapy: New prospects (also) for 4D?
Prompt-Gamma Based Range Verification in Particle Therapy: New prospects (also) for 4D? Guntram Pausch 1-3 1 OncoRay National Center for Radiation Research in Oncology, Dresden 2 Technische Universität
More informationIQM Detector Characteristics: Signal reproducibility
The Integral Quality Monitor (IQM) System is a real-time beam verification system that monitors the accuracy of radiation delivery throughout each patient treatment without any user interaction. IQM continuously
More informationYasar Onel, University of Iowa; Dave Winn, Fairfield Univ. 1/20/2005
Project name R&D for luminosity monitor Classification (accelerator: subsystem) IPBI / Accelerator Institution(s) and personnel University of Iowa, Department of Physics and Astronomy: Yasar Onel (professor)
More informationEvaluation of X-Ray Beam Quality Based on Measurements and Estimations Using SpekCalc and Ipem78 Models
Original Article Evaluation of X-Ray Beam Quality Based on Measurements and Estimations Using SpekCalc and Ipem78 Models Suk Chiang Chen, Wei Loong Jong, Ahmad Zaky Harun Submitted: 20 Aug 2011 Accepted:
More informationStrategy and framework applicable to knowledge transfer by CERN for the benefit of medical applications
CERN/SPC/1091 Original: English 23 June 2017 ORGANISATION EUROPEENNE POUR LA RECHERCHE NUCLEAIRE CERN EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH Action to be taken Voting Procedure For information SCIENTIFIC
More informationGAFCHROMIC. Therapy Dosimetry Media Models to
GAFCHROMIC Therapy Dosimetry Media Models 37-040 to 37-045! Superior uniformity and sensitivity! Dose rate and fractionation independent! Maps dose distribution! Provides quantitative measurements (via
More informationTechnology Transfer at CERN
Technology Transfer at CERN Enrico Chesta Head of CERN Technology Transfer and Intellectual Property Management Section Knowledge Transfer Group, FP Department How can CERN have an impact beyond fundamental
More informationA STUDY OF THE RESPONSE OF DEPLETED TYPE p-mosfets TO PHOTON AND ELECTRON DOSE
A STUDY OF THE RESPONSE OF DEPLETED TYPE p-mosfets TO PHOTON AND ELECTRON DOSE M. Fragopoulou 1, S. Stoulos 1, and M. Zamani 1, 1 School of Physics, Nuclear and Elementary Particle Section Aristotle University
More informationDose conversion coefficients for electron exposure of the human eye lens
Physics in Medicine & Biology CORRIGENDUM Dose conversion coefficients for electron exposure of the human eye lens To cite this article: R Behrens et al 2010 Phys. Med. Biol. 55 3937 View the article online
More informationAPPENDIX K UNF RADIATION GENERATING DEVICE SAFETY PROCEDURES
APPENDIX K UNF RADIATION GENERATING DEVICE SAFETY PROCEDURES Policy and Purpose This policy provides administrative control over the use of radiation generating devices and is designed to ensure that such
More informationSRS MapCHECK. SRS Patient QA, No Film. Your Most Valuable QA and Dosimetry Tools
SRS MapCHECK SRS Patient QA, No Film Your Most Valuable QA and Dosimetry Tools SRS Patient QA, No Film As clinics strive to treat with the smallest field possible, the demand for SRS/SBRT QA grows as well.
More informationDevelopment of new dosimeter for measuring dose distribution in CT
Development of new dosimeter for measuring dose distribution in CT Poster No.: C-2925 Congress: ECR 2010 Type: Scientific Exhibit Topic: Physics in Radiology - Without Subtopic Authors: Y. Muramatsu, K.
More informationLinear electron accelerators for radiation processing MIKHAIL DEMSKY, CORAD LTD, ST. PETERSBURG, RUSSIA (
Linear electron accelerators for radiation processing MIKHAIL DEMSKY, CORAD LTD, ST. PETERSBURG, RUSSIA (WWW.CORAD.PRO) How linear electron accelerator (linac) accelerates electrons: A scheme of a linac
More informationQuality control of Gamma Camera. By Dr/ Ibrahim Elsayed Saad 242 NMT
Quality control of Gamma Camera By Dr/ Ibrahim Elsayed Saad 242 NMT WHAT IS QUALITY? The quality of a practice is to fulfill the expectations and demands from: Patient Clinicain Your self Quality assurance
More informationMonte Carlo Simulation of the PRad Experiment at JLab 1
Monte Carlo Simulation of the PRad Experiment at JLab 1 Li Ye Mississippi State University for the PRad collaboration 1.This work is supported in part by NSF MRI award PHY-1229153, the U.S. Department
More informationClick to edit Master title style
Greetings from Serpent Developer Team 5th International Serpent UGM, Knoxville, TN, Oct. 13-16, 2015 Jaakko Leppänen VTT Technical Research Center of Finland Click to edit Master title Background style
More informationThe Current State of EPID-Based Linear Accelerator Quality Assurance. Disclosures. Purpose of this First Talk 8/3/2017
The Current State of EPID-Based Linear Accelerator Quality Assurance Timothy Ritter, PhD, DABR, FAAPM 1 Disclosures Employed by the Veterans Health Administration Faculty appointment with the University
More informationCharacterization of an in vivo diode dosimetry system for clinical use
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 4, NUMBER 2, SPRING 2003 Characterization of an in vivo diode dosimetry system for clinical use Kai Huang, 1, * William S. Bice, Jr., 2, and Oscar Hidalgo-Salvatierra
More informationResponse characteristics of a tandem ionization chamber in standard X-ray beams
Applied Radiation and Isotopes 58 (2003) 495 500 Response characteristics of a tandem ionization chamber in standard X-ray beams Alessandro M. Costa*, Linda V.E. Caldas Instituto de Pesquisas Energ!eticas
More informationConcluding remarks. Makoto Asai (SLAC SD/EPP) April 19th, 2015 Geant4 MC2015
Concluding remarks Makoto Asai (SLAC SD/EPP) April 19th, 2015 Geant4 Workshop @ MC2015 Contents The SLAC Geant4 team sincerely hope you could enjoy our workshop and you found it informa=ve and useful.
More informationGATE users meeting Nuclear Science Symposium and Medical Imaging Conference. Organized by the OpenGATE collaboration
2011 Nuclear Science Symposium and Medical Imaging Conference GATE users meeting Organized by the OpenGATE collaboration 2011 Nuclear Science Symposium and Medical Imaging Conference - GATE users meeting,
More informationHow Gamma Camera s Head-Tilts Affect Image Quality of a Nuclear Scintigram?
November 2014, Volume 1, Number 4 How Gamma Camera s Head-Tilts Affect Image Quality of a Nuclear Scintigram? Hojjat Mahani 1,2, Alireza Kamali-Asl 3, *, Mohammad Reza Ay 2, 4 1. Radiation Application
More informationX-ray tube with needle-like anode
NUKLEONIKA 2002;47(3):101 105 ORIGINAL PAPER X-ray tube with needle-like anode Mieczys aw S apa, W odzimierz StraÊ, Marek Traczyk, Jerzy Dora, Miros aw Snopek, Ryszard Gutowski, Wojciech Drabik Abstract
More informationQA Considerations. QA for LGK Perfexion : : Follow NRC licensing guidelines (10( CFR ) Leksell Gamma Knife Perfexion
Leksell Gamma Knife Perfexion QA Considerations Paula L. Petti, Ph.D. Taylor McAdam Bell Neuroscience Institute Washington Hospital Healthcare System Fremont, CA 1 QA for LGK Perfexion : : Follow NRC licensing
More informationFailures of MOSFETs in Terrestrial Power Electronics Due to Single Event Burnout
Failures of MOSFETs in Terrestrial Power Electronics Due to Single Event Burnout C. Donovan Davidson P.Eng. V.P. of Research and Development Argus Technologies Ltd. 5700 Sidley St., Burnaby, B.C. V5J5E5
More informationAim. Images for this section: Page 2 of 13
Changes in CT number of high atomic number materials with field of view when using an extended CT number to electron density curve and a metal artifact reduction reconstruction algorithm Poster No.: R-0094
More information8/3/2017. Use of EPIDs for Non-Routine Linac QA. Disclosure. Learning Objectives. Parts of this project received support from Varian Medical System.
Use of EPIDs for Non-Routine Linac QA Bin Cai PhD Disclosure Parts of this project received support from Varian Medical System. Learning Objectives Learn the recent development of EPID based Non-routine
More informationSTEM School Chattanooga
STEM School Chattanooga 9th Grade PBL Unit Plan Template Unit 6: Medicine - Viral Outbreak Learning Target Topics Art Science Mathematics Art I: Choose and apply subject matter to communicate an idea;
More informationA study of GafChromic XR Type R film response with reflective-type densitometers and economical flatbed scanners
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 4, NUMBER 4, FALL 2003 A study of GafChromic XR Type R film response with reflective-type densitometers and economical scanners G. Thomas, 1, * R. Y.
More informationMonte Carlo simulations for the JEDI polarimeter at COSY
Monte Carlo simulations for the JEDI polarimeter at COSY Paul Maanen on behalf of the JEDI Collaboration JEDI Collaboration Physics Institute III B, RWTH Aachen University DPG Frühjahrstagung 216 Outline
More informationReport to the 49th Regular Session of the IAEA General Conference from the 8th Scientific Forum
Report to the 49th Regular Session of the IAEA General Conference from the 8th Scientific Forum Chairman Prof. Burton Richter, Director Emeritus at the Stanford Linear Accelerator Centre (SLAC) 29 September
More informationHISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD
CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging Shawn D. Teague, MD DISCLOSURES 3DR- advisory committee CT PHYSICS WITH AN EMPHASIS ON APPLICATION IN THORACIC AND CARDIAC IMAGING
More informationElectronic Brachytherapy Sources. Thomas W. Rusch
Electronic Brachytherapy Sources Thomas W. Rusch Educational Objectives Understand key elements of ebx source construction & operation Understand the rationale and methods for air kerma strength calibration
More informationAssessment of BLM Thresholds in Collimation Regions for the LHC startup
Assessment of BLM Thresholds in Collimation Regions for the LHC startup By Till Böhlen & BLM Team 1/11 Content Introduction to Protection of Collimators Approach & Work so far Experiment @ SPS & Simulations
More informationImaging Cerenkov emission as a quality assurance tool in electron radiotherapy
TB, VB, UK, PMB/484054, 11/03/2014 Phys. Med. Biol. 59 (2014) 1 16 Institute of Physics and Engineering in Medicine Physics in Medicine and Biology UNCORRECTED PROOF Imaging Cerenkov emission as a quality
More informationIONIZING RADIATION 2018 / 2019 DETECTORS. Including Codes of Practice
IONIZING RADIATION DETECTORS 2018 / 2019 Including Codes of Practice PTW History and General Remarks Looking back on a long history PTW-Freiburg is an internationally operating company, manufacturing and
More informationPolitecnico di Torino. Porto Institutional Repository
Politecnico di Torino Porto Institutional Repository [Proceeding] Development of a front-end electronics for an innovative monitor chamber for high-intensity charged particle beams Original Citation: Guarachi,
More information7/23/2014. Acknowledgements. Implementing a new digital medical accelerator. New Generation of Medical Accelerators
Implementing a new digital medical accelerator John Wong Johns Hopkins University AAPM, Austin, 2014 Acknowledgements Yin Zhang, Ken Wang, Kai Ding (Commissioning - JHU) Esteban Velarde, Joe Moore (QA
More informationDevelopment of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA
Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA Gena M.A.H 1, Ahmed L.El-Attar 2, Elbadry M. Zahran 3, Hany El-Gamal
More informationNuclear Associates
Nuclear Associates 07-706 Patient Phantom/Penetrometer System Users Manual March 2005 Manual No. 07-706-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are
More informationClinical Experiences with a Patient Skin Dose Monitoring and Tracking Program
Clinical Experiences with a Patient Skin Dose Monitoring and Tracking Program Allen R. Goode, MS, DABR Chief Diagnostic Medical Physicist Department of Radiology & Medical Imaging University of Virginia
More informationTitle Page US-Geant4 Consortium Multi-year Roadmap for Geant4 Development and Support
Title Page US-Geant4 Consortium Multi-year Roadmap for Geant4 Development and Support Makoto Asai, Tatsumi Koi, Richard Mount, Joseph Perl, Dennis Wright SLAC National Accelerator Laboratory Sunanda Banerjee,
More informationDetecting and Suppressing Background Signal
Detecting and Suppressing Background Signal Valerie Gray St. Norbert College Advisors: Dr. Michael Wiescher Freimann Professor Nuclear Physics University of Notre Dame Dr. Ed Stech Associate Professional
More informationPATIENT EFFECTIVE DOSES IN DIAGNOSTIC RADIOLOGY, NA
Title of Paper: Patient effective doses in diagnostic radiology Authors: N.A. Gkanatsios, and W. Huda * Corresponding Author: Department of Radiology, University of Florida, P.O. Box 100374, Gainesville,
More informationBeam Loss Monitoring (BLM) System for ESS
Beam Loss Monitoring (BLM) System for ESS Lali Tchelidze European Spallation Source ESS AB lali.tchelidze@esss.se March 2, 2011 Outline 1. BLM Types; 2. BLM Positioning and Calibration; 3. BLMs as part
More informationSimulation and evaluation of a cost-effective high-performance brain PET scanner.
Research Article http://www.alliedacademies.org/biomedical-imaging-and-bioengineering/ Simulation and evaluation of a cost-effective high-performance brain PET scanner. Musa S Musa *, Dilber U Ozsahin,
More informationThermoplastic Fixation Masks
Thermoplastic Fixation Masks Radiation Therapy Solutions 1.877.338.6857 www.ultraraymedical.com CANADA S TRUSTED SOURCE FOR IMAGING PRODUCTS Ultraray Medical is a trusted source for Diagnostic Imaging
More information3D Diode Array Commissioning: Building Confidence in 3D QA Technology
3D Diode Array Commissioning: Building Confidence in 3D QA Technology Caroline Yount, MS CANCER CENTER 3D QA The complex three-dimensional (3D) shapes of intensity modulated radiation therapy (IMRT) dose
More informationCalculation of Remanent Dose Rate Maps in the LHC Beam Dump Caverns
EDMS Document Number: 784972 ORGANISATION EUROPENNE POUR LA RECHERCHE NUCLEAIRE EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH Laboratoire Européen pour la Physique des Particules European Laboratory for Particle
More informationLDR Prostate Medical Event Definition. John Wochos, MS Gundersen Lutheran La Crosse, Wisconsin April 22, 2011
LDR Prostate Medical Event Definition John Wochos, MS Gundersen Lutheran La Crosse, Wisconsin April 22, 2011 Conflicts of Interest NONE Three LDR Medical Events at GLMC Outline Definition of Medical Event
More informationSpace&Environment&Technologies&ARMAS7Lite&FM2& &Proprietary& & ARMAS LITE FM2 SPECIFICATION SHEET REVISION&HISTORY&
SpaceEnvironmentTechnologiesARMAS7LiteFM2 Proprietary ARMAS LITE FM2 SPECIFICATION SHEET Product name Product purpose Product reference ARMAS Lite Flight Module 2 (FM2) Radiation Detection Instrumentation
More informationFeatures and Weaknesses of Phantoms for CR/DR System Testing
Physics testing of image detectors Parameters to test Features and Weaknesses of Phantoms for CR/DR System Testing Spatial resolution Contrast resolution Uniformity/geometric distortion Dose response/signal
More information