n Compliance with IEEE 519 and other Power Quality standards n Long-term savings in system operation and maintenance cost
|
|
- Earl Tucker
- 6 years ago
- Views:
Transcription
1 Harmonic ilters N 3410/11 / N3412/13 Osine dvanced Passive Harmonic ilters n fficient mitigation of harmonic currents n ompliance with I 519 and other Power Quality standards n Increased equipment service life and system reliability n More efficient utilization of electric system capacity n Long-term savings in system operation and maintenance cost pprovals Technical specifications Nominal operating voltage: 3x 380 to 500V ±10% (N 3410/11) 3x 380 to 480V ±10% (N 3412/13) Operating frequency: 50Hz ±1Hz (N 3410/11) 60Hz ±1Hz (N 3412/13) Nominal motor drive input power rating: 4 to 200kW (N 3410/11) 5 to 250HP (N 3412/13) Total harmonic current distortion THID**: <5 rated power Total demand distortion TDD: ccording to I-519, table 10-3 fficiency: 98.5 to nominal line voltage and power High potential test voltage: P > 2500V (1min) Protection category: IP20 / NM1 ooling: Internal fan cooling Overload capability: 1.6x rated current for 1 minute, once per hour mbient temperature range: 25 to +50 fully operational +50 to +70 derated operation*** 25 to +85 transport and storage lammability corresponding to: UL 94V-2 or better Design corresponding to: UL 508, N , (LVD 2006/95/) 50 /460V (Mil-H-217): 200,000 hours SR****: 100k * Osine filters reduce RMS input and peak current by reducing harmonic currents and improving true power factor. ** System requirements: THVD <2%, line voltage unbalance <1% Note: performance specifications in this brochure refer to six-pulse diode rectifiers. SR rectifier front-ends will produce different results, dependent upon the firing angle of the thyristors. *** I derated = I nominal * (85 -T amb )/35 **** xternal UL-rated fuses required. Please consult the user manual. Typical electrical schematic Line L1 L2 L3 P Power capacitors Trap choke In-Out choke Power supply an ontrol error cooling power on red yellow green LD L1' Load L2' L3' NO Disconnect Monitor eatures and benefits Schaffner Osine harmonic filters represent an economical solution to the challenge of load-applied harmonics mitigation in three-phase power systems. With a plug-and-play approach and more compact dimensions than comparable products, they can be quickly installed and easily commissioned. They increase the reliability and service life of electric installations, help utilize electric sytem capacity better, and are the key to meet Power Quality standards such as I 519. Osine filters calm your harmonic waves. Schaffner Osine filters can be applied to virtually any kind of power electronics with front-end six-pulse rectifiers, where harmonic current distortion needs to be reduced to defined limits. Typical applications, where the above-mentioned non-sinusoidal consumers of power can account for a significant portion of the load, include: Typical applications n quipment with front-end six-pulse rectifier n Motor drives n actory automation equipment n Water/wastewater treatment facilities n an and pump applications n HV installations n Mission-critical processes n D fast chargers
2 > omponents > N 3410/11 / N3412/13 ilter selection table N 3410/ V/50Hz Power 400V/500V Input/Output connections apacitor disconnections Weight NM1 covers*** [kw] [kw] [W] [kg] Order code N 341x / N 341x / N 341x / N 341x / N 341x / N 341x / N 341x / N 341x / N 341x / N 341x / N 341x / N 341x / N 341x / N 341x / N 341x / N 341x / * To compile a complete part number, please replace the x with a 0 for diode or 1 for SR rectifiers. ilter to be selected by system voltage and load (motor drive) power. Note: the harmonic filter will reduce the RMS input current. xample: the rated RMS input current of an unfiltered 400V/15kW/32 drive will be reduced to approximately 23. Therefore, filter selection by current rating, as it is common for M/MI filters, is not suitable. ** alculated power loss at rated load power. *** Please contact your local Schaffner partner to order the optional NM1 covers with the order code in the table above. ilter selection table N 3412/13 460V/60Hz Power 460V Input/Output connections apacitor disconnections Weight NM1 covers*** [HP] [W] [kg] Order code N 341x N 341x N 341x N 341x N 341x N 341x N 341x N 341x N 341x N 341x N 341x N 341x N 341x N 341x N 341x N 341x * To compile a complete part number, please replace the x with a 2 for diode or 3 for SR rectifiers. ilter to be selected by system voltage and load (motor drive) power. Note: the harmonic filter will reduce the RMS input current. xample: the rated RMS input current of an unfiltered 460V/20HP/28 drive will be reduced to approximately 20. Therefore, filter selection by current rating, as it is common for M/MI filters, is not suitable. ** alculated power loss at rated load power. *** Please contact your local Schaffner partner to order the optional NM1 covers with the order code in the table above. Osine Mains N (110kW/400V) Non-linear load 1: 30kW/400V Non-linear load 2: 75kW/400V
3 > omponents > N 3410/11 / N3412/13 Mechanical data N 3410/ N to -110 N 3410/ N to -210 N 3412/ N to -130 N 3412/ N and -190 N 3410/ N and -320 Installation. ll filters from N 341x-8 to -130 are wall N 3412/ N and -310 mountable and have to be operated vertically. The filters N 341x-150 and higher are designed for floor mounting. In order to allow for sufficient air flow all filters must be clear on top and bottom min. 150mm. Optional NM1 cover. ll filters can be optionally fitted with a NM1 cover. Please find order codes on previous pages. W Z V X Y
4 > omponents > N 3410/11 / N3412/13 Dimensions N 3410/ N N 3412/ N x30 14x30 14x30 14x30 14x30 M6 M6 M6 M6 M8 M8 M8 M8 M8 M10 M10 M10 M10 M10 M10 M10 M10 V W 6 6 X Y Z ll dimensions in mm; 1 inch = 25.4mm Tolerances according: ISO 2768-m / N m ilter connector cross sections Solid wire 16mm 2 35mm 2 50mm 2 95mm 2 10mm 2 lex wire 10mm 2 25mm 2 50mm 2 95mm 2 6mm 2 W type wire W 6 W 2 W 1/0 W 4/0 W 8 Recommended torque Nm Nm 7 8Nm 17 20Nm Nm Please visit to find more details on filter connectors. Your local partner: To find your local partner within Schaffner s global network, please go to May 2011
5 Headquarters and global innovation and development center Schaffner roup Nordstrasse Luterbach Switzerland T info@schaffner.ch Sales and application centers hina Schaffner M Ltd. Shanghai uilding 11, Lane 1365 ast Kangqiao Road Shanghai T cschina@schaffner.com ermany Schaffner Deutschland mbh Schoemperlenstrasse Karlsruhe T germanysales@schaffner.com inland Schaffner Oy Tynninkuja Lohja T finlandsales@schaffner.com rance Schaffner M S..S. 112, Quai de ezons rgenteuil T francesales@schaffner.com Italy Schaffner M S.r.l. Via alileo alilei, inisello alsamo (MI) T / italysales@schaffner.com apan Schaffner M K.K. Mitsui-Seimei Sangenjaya ldg , Kamiuma, Setagaya-ku Tokyo T japansales@schaffner.com Sweden Schaffner M Turebergstorg 1, Sollentuna T / swedensales@schaffner.com Switzerland Schaffner MV Nordstrasse Luterbach T sales@schaffner.ch Singapore Schaffner M Pte Ltd. lk 3015 Ubi Road Kampong Ubi Industrial state T singaporesales@schaffner.com Spain Schaffner M spaña alle aléndula 93, Miniparc III, dificio l Soto de la Moraleja, lcobendas Madrid T spainsales@schaffner.com Taiwan Schaffner MV Ltd. 6th loor, No 413 Rui uang Road Neihu District Taipei ity 114 T taiwansales@schaffner.com Thailand Schaffner M o. Ltd. Northern Region Industrial state 67 Moo 4 Tambon an Klang mphur Muang P.O. ox 14 Lamphun T thailandsales@schaffner.com UK Schaffner Ltd. 5 shville Way Molly Millars Lane Wokingham erkshire R41 2PL T uksales@schaffner.com US Schaffner M Inc. 52 Mayfield venue dison, New ersey T usasales@schaffner.com /us To find your local partner within Schaffner s global network, please go to May Schaffner M. Specifications subject to change without notice. ll trademarks recognized. Schaffner is an ISO-registered company. Its products are designed and manufactured under the strict quality and environmental requirements of the ISO 9001 and ISO standards. This document has been carefully checked. However, Schaffner does not assume any liability for errors or inaccuracies.
FN Ecosine evo, 60 Hz Passive Harmonic Filters
DATASHEET Ecosine Evo line (5% evo THID) FN 3452-300-118-E2FAJXX FN Ecosine evo, 60 Hz Passive Harmonic Filters The industry standard for 6-pulse rectifier and motor drives Filters for diode rectifier
More informationECOsine Passive. Advanced Passive Harmonic Filters.
ECOsine Passive 1 2013 ECOsine Passive Advanced Passive Harmonic Filters www.myecosine.com ECOsine Passive schaffner Group The Schaffner Group is the international leader in development and production
More informationPersonalized Product Catalog
PRODUCT CATALOG JULY 2015 Personalized Product Catalog Product Index FN 2020 1-4 FN 2060 5-8 FN 2070 9-12 FN 3258 13-14 FN 3268 15-16 FN 3270 17-19 FN 3256 20-21 FN 3280 22-23 DATASHEET Single-Stage Filters
More informationEMC/EMI Chokes CHOKES CATALOG MARCH How to select the right choke family
EMC/EMI Chokes CHOKES CATALOG MARCH 2018 EMC/EMI Chokes How to select the right choke family 1 2 EMC/EMI Chokes 1. Introduction and general comments Chokes No Common Yes Differential chokes Saturating
More informationECOsine Active Increased reliability in building technology
Application example ECOsine Active Increased reliability in building technology www.myecosine.com The show will go on thanks to ECOsine Active For a unique, internationally-esteemed concert hall like the
More informationCurrent-compensated Chokes
M/MI Products M/MI hokes R Series urrent-compensated hokes Rated currents from 16 to 50 Up to 0 V or 1000 V 2- and 3-wire configurations Horizontal and vertical P mounting types Ruggedized saturation and
More informationEMC/EMI Chokes How to select the right choke family
EMC/EMI Chokes 1 CHOKES CATALOG APRIL 2019 EMC/EMI Chokes How to select the right choke family 2 EMC/EMI Chokes 1. Introduction and general comments Chokes No Common Yes Differential chokes Saturating
More informationCurrent-compensated Chokes
M/MI Products M/MI hokes R Series urrent-compensated hokes I Rated currents from 16 to 50 I Up to 0 V or 1000 V I 2- and 3-wire configurations I Horizontal and vertical P mounting types I Ruggedized saturation
More informationProduct selection chart
Schaffner EMC Product selection chart 2009 DC EMC & output filters 1-phase China Schaffner EMC Ltd. Shanghai T +86 21 6813 9855 cschina@schaffner.com Spain Schaffner EMC España T +34 618 176 133 spainsales@schaffner.com
More informationTest Systems. VSQ 3000/3002 Reference Radiation Source up to 3GHz
Test Systems VSQ 3000/3002 Reference Radiation Source up to 3GHz VSQ 3000/3002. This new series enables the user to check measuring setup parameters of open area test sites, anechoic chambers and other
More informationHarmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions
Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE - 519 Solutions Harmonics Tutorial 1 Power Conversion Equipment can save energy and control motors, heaters,
More informationUser and Installation Manual
Ecosine evo Passive Harmonic Filters Ecosine evo FN 3440/FN 3441 (50 Hz) for 380 415 V AC FN 3450/FN 3451 (50 Hz) for 440 500 V AC FN 3452/FN 3453 (60 Hz) for 440 480 V AC Schaffner Group Nordstrasse 11
More informationInstallation Manual. Passive Harmonic Filters. ECOsine Economy Line & ECOsine Economy Line LV
Passive Harmonic Filters ECOsine Economy Line & ECOsine Economy Line LV Schaffner Group Nordstrasse 11 4542 Luterbach Switzerland T +41 32 681 66 26 F+ 41 32 681 66 30 www.schaffner.com 210/50 FN3416 (50Hz)
More informationECOsine Passive Harmonic Filters
Nordstrasse 11 4542 Luterbach Switzerland T +41 32 681 66 26 F +41 32 681 66 30 www.schaffner.com energy efficiency and reliability Application Note The field guide to harmonics mitigation and energy efficiency
More informationInstallation Manual. Passive Harmonic Filters. ECOsine Full Performance Line
Passive Harmonic Filters ECOsine Full Performance Line Schaffner Group Nordstrasse 11 4542 Luterbach Switzerland T +41 32 681 66 26 F+ 41 32 681 66 30 www.schaffner.com 22/48 The field guide to harmonics
More informationGE Energy. Matrix Harmonic Filter Series D
GE Energy Matrix Harmonic Filter Series D Matrix Harmonic Filter GE Matrix Harmonic Filters provide broadband reduction of harmonics. Matrix Harmonic Filters not only offer better performance over other
More informationRFI SUPPRESSION CHOKES. rod-cored, saturating and current compensated types SCHAFFNER. Your number one name for EMC
R SUPPRSSON OS rod-cored, saturating and current compensated types SNR Your number one name for M R suppression chokes ONTNTS eneral information hoke range... ntroduction to M & key standards... Types
More informationCBA 400M MHZ to 400 MHZ
1 CBA 400M-100 1 MHZ to 400 MHZ 100 watt amplifier user Manual 601-298A CBA 400M-100 1 MHZ to 400 MHZ 100 watt amplifier USER Manual CBA 400M-100 User Manual contents 1 Safety information 5 2 Introduction
More informationMD 200A High voltage differential probe
1 MD 200A High voltage differential probe User Manual 601-265B MD 200A High voltage differential probe User Manual MD 200A high voltage differential probe contents 1 Safety terms and symbols 5 2 Safety
More informationOctober ECOsine active Harmonic Filters Failure analysis 100A/120A 4-Wire
October 2018 ECOsine active Harmonic Filters Failure analysis 100A/120A 4-Wire Failure analysis 100A/120A 4-Wire 1. Intended use The ECOsine active harmonic filter is used for active compensation of reactive
More informationAdvanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS
Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS Highly Efficient, System-Designed Solutions for Harmonic Distortion Introducing Danfoss Advanced Harmonic Solutions (AHS) Danfoss
More informationAdvanced Test Equipment Rentals ATEC (2832) EMC Calibration ServiCES. Reliable fast worldwide
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) EMC Calibration ServiCES Reliable fast worldwide GLOBAL 6 accredited calibration and repair centers. NATIONAL Accredited
More informationPowerFlex Medium Voltage Drives with Direct-to-Drive Technology Eliminating the Isolation Transformer
PowerFlex Medium Voltage Drives with Direct-to-Drive Technology Eliminating the Isolation Transformer Transformerless drives help industry reduce the cost of motor control while using standard motors.
More informationOctober Ecosine active Harmonic Filters Failure analysis 30A/50A 3-Wire
October 2018 Ecosine active Harmonic Filters Failure analysis 30A/50A 3-Wire Failure analysis 30A/50A 3-Wire 1. Intended use The Ecosine active harmonic filter is used for active compensation of reactive
More informationHarmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017
Harmonics and Their Impact on Power Quality Wayne Walcott Application Engineering Manager June, 2017 Presentation Overview A little about harmonics What are harmonics What are NOT harmonics What creates
More informationEconomical Solutions to Meet Harmonic Distortion Limits[4]
Economical Solutions to Meet Harmonic Distortion Limits[4] Abstract: The widespread adoption of variable frequency drive technology is allowing electricity to be utilized more efficiently throughout most
More informationValue Unit I T(RMS) RMS on-state current A A Tj = 25 C I FSM current (Tj initial = 25 C)
MAIN FEATURES: DIODE / SCR MODULE Symbol Value Unit I T(RMS) 50-70-85 A V DRM /V RRM 800 and 1200 V I GT 50 and 100 ma DESCRIPTION Packaged in ISOTOP modules, the MDS Series is based on the half-bridge
More informationACPOWER. Profession Power Solution Provider R E G D E ISO 9001:2008
A POW Ground-Military Power Units AMF Series 500VA~400KVA 400Hz Solid State onverter Profession Power Solution Provider G IS T D UKAS 00 ISO 900:008 A POW AMF- put 060 F T apacity Outlook 60KVA Free Standing
More informationElectrical Specifications
usiness-ritical ontinuity L Watts onvection/onduction Mounting Rev. 1..1_11 L Series 1 of 7 Total Power: W # of Outputs: Single Output: 1,, 8 V Special Features W Full power at elevated temperatures Wide
More informationB2...VS Series, 2-way, Ball Valve Bronze Body, Stainless Steel Ball and Stem
2...VS Series, 2-way, all Valve ronze ody, Stainless Steel all and Stem Live-load packing set Stainless steel ball & stem low-out proof stem design Technical Data Media chilled or hot water, glycol, #
More informationOutput Current Efficiency (1)
HD5 eries C-DC ower upplies 5 Watts xxx eries High fficiency up to 9% High ower Density rogrammable Output oltage (-5%) rogrammable Output Current (-5%) arallel Operation Fully Featured ignals & Controls
More informationReduce harmonics in HVAC&R inverters through C-Less technology
Reduce harmonics in HVAC&R inverters through C-Less technology Karim Lamrabtine Global Product Manager VSD 14-15 SEPTEMBER 2011, MUNICH Agenda www.infoplc.net What are Harmonics? Standards Compliance How
More information120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240
Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to
More informationIRPT2062A IRPT2062A. Power Module for 3 hp Motor Drives. 3 hp (2.2 kw) power output
PRELIMINARY PD 6.122 3 hp (2.2 kw) power output Industrial rating at 150% overload for 1 minute 380-480V AC input, 50/60 Hz 3-phase rectifier bridge 3-phase, short circuit rated, ultrafast IGBT inverter
More informationMV1000 MEDIUM VOLTAGE AC DRIVE 175 HP TO 16,000 HP
MV1000 MEDIUM VOLTAGE AC DRIVE 175 HP TO 16,000 HP MV1000 MEDIUM VOLTAGE AC DRIVE Simple Robust Compact Reliable Safe Feature Packed Input Fused Disconnect with Contactor Cooling Fans Control Section Multi-Pulse
More informationIRPT3054A IRPT3054A. Power Module for 5 hp Motor Drives. 5 hp (3.7 kw) power output
PROVISIONAL IRPT3054A Power Module for 5 hp Motor Drives 5 hp (3.7 kw) power output Industrial rating at 150% overload for 1 minute 380-480V AC input, 50/60 Hz 3-phase rectifier bridge 3-phase, short circuit
More informationGeneral Purpose Drives
AC Variable Speed Drive General Purpose Drives Dedicated to Low Power Applications 0.37kW 11kW / 0.5HP 15HP 200 480V 3 Phase Input AC Variable Speed Drive 0.37kW 11kW / 0.5HP 15HP 110 480V Single & 3 Phase
More informationThis Chapter contains:
7 This Chapter contains: Table 7.1 Table 7-2 Table 7-3 Table 7-4 contains the general technical specifications for the MICROMASTER 430 inverter contains terminal tightening torques and the required cooling
More informationElectrical Specifications
usiness-ritical ontinuity L Watts onvection/onduction Mounting Rev. 1.31.11_11 L Series 1 of 7 Total Power: W # of Outputs: Single Output: 1,, 8 V Special Features 1 VD / W output power Wide Operating
More informationDelta Power Meter DPM Series
utomation for a hanging World Delta Power Meter DPM Series www.deltaww.com Product Introduction Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power quality
More informationDelta Power Meter DPM Series
utomation for a hanging World Delta Power Meter DPM Series www.deltaww.com Product Introduction Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power quality
More informationCWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ
CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC 61000-4-16, IEC 61000-4-19 ANNEX C, 0HZ (DC) TO 165KHZ FOR TESTS ACCORDING TO... > EN 61000-4-16 > IEC 60255-22-7 > IEC 60255-26
More informationIRPT1057A IRPT1057A. Power Module for 0.75 hp Motor Drives hp (0.56kW) power output
PRELIMINARY IRPT1057A PD 6.112 IRPT1057A 0.75 hp (0.56kW) power output Industrial rating at 150% overload for 1 minute 180-240V AC input, 50/60 Hz 3-phase rectifier bridge 3-phase, short circuit rated,
More informationProduct Catalog PRODUCT CATALOG. Power supply system & test equipment
Product Catalog PRODUCT CATALOG 2018 2018 Power supply system & test equipment. 138/79, Moo 2 Tambon Ban Klang, Amphoe Mueang Pathumthani, Pathumthani Province 12000, Thailand. Tel: +66 21475048-9 Fax:
More informationPower loss. Leakage current 400VAC/50Hz ma
Ultra-compact 3-phase filter FN 3258 7 to 18 current ratings xceptional attenuation from 1kHz to MHz xcellent saturation resistance to m cable length Very compact footprint and low weight Nennströme von
More informationTMdrive -XL Series Family Product Application Guide. solar inverters. power generation
TMdrive -XL Series Family Product Application Guide metals cranes mining testing oil & gas solar inverters power generation cement TMdrive-XL Series 8 MVA 15 MVA 20 MVA 30 MVA The TMdrive XL series family
More informationAPQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)
APQline Active Harmonic Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Power electronic equipment and AC-DC power conversion equipment contribute
More informationLiebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS
Liebert Hipulse-U Fully Digital Dual DSP Controlled Transformer Based UPS Addressing a Variety of Needs The Liebert Hipulse-U offers a reliable, scalable and user-friendly solution to ensure availability
More informationLow Pass Harmonic Filters
Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power
More informationP2075B100-P, 3/4, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends
P2075100-P, 3/4, Pressure Independent Valve hrome Plated rass all and rass Stem, NPT emale nds pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating
More informationSTTH3012. Ultrafast recovery V diode. Main product characteristics. Features and benefits. Description. Order codes DO-247 STTH3012W
STTH312 Ultrafast recovery - 1 V diode Main product characteristics I (V) V RRM T j V (typ) t rr (typ) eatures and benefits Ultrafast, soft recovery 3 1 V 175 C 1.3 V 57 ns Very low conduction and switching
More information2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives
.0 Volume 6 Solid-State Control CA0800007E March 05 www.eaton.com V6-T-47 .0 Adjustable Frequency Drives Overview What Are Harmonics? Take a perfect wave with a fundamental frequency of 60 Hz, which is
More informationIRPT1053A. POWIRTRAIN Power Module for 1 hp Motor Drives
1 hp (0.75kW) power output Industrial rating at 150% overload for 1 minute 180-240V AC input, 50/60Hz 3-phase rectifier bridge 3-phase ultrafast IGBT inverter HEXFRED ultrafast soft recovery freewheeling
More informationVFDs and Harmonics in HVAC Applications
VFDs and Harmonics in HVAC Applications Larry Gardner Product Marketing Manager Yaskawa America, Inc. Jeff Grant Senior Sales Engineer LONG Building Technologies October 20, 2016 2016 Yaskawa America,
More informationGreen Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500 US EDITION
Green Scan Laser PhotocoagulatorGYC-500 Vixi Green Laser PhotocoagulatorGYC-500 US EDITION The Small, Incredibly Versatile Green Laser Photocoagulator The GYC-500 Vixi / GYC-500 is a solid state green
More informationEffective Harmonic Mitigation with Active Filters
Advancing Power Quality White Paper Effective Harmonic Mitigation with Active Filters Written by: Ian Wallace Variable Speed Drive with no Harmonic Mitigation Industry standard variable speed drives, with
More informationResilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc
Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc Product Description The Resilient 3000 is a high Efficiency, single phase, general purpose and ruggedized fan cooled rectifier for stand alone
More informationATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW
Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device
More informationINA 703 MAgNetIc field coil
1 INA 703 MAgNetIc field coil User MANUAl 601-335B INA 703 Magnetic field coil User manual INA 703 Magnetic field coil contents 1 Explanation of symbols 5 2 Introduction 6 2.1 General description 6 2.2
More informationEMC and Power Quality Solutions for Industrial Power Systems 2011/12
EMC and Power Quality Solutions for Industrial Power Systems 2011/12 Product Selection Chart DC EMC & output filters 1-phase Number of phases 3-phase DC filters Feedthrough components 13A PCB filters IEC
More informationATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW
Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More information2.1.2 Abbreviations CE Conformity and Labelling EMC-Directive 2004/108/EG Warnings 5
Contents Contents 1 How to Read this Design Guide 3 2 Safety and Conformity 4 2.1.2 Abbreviations 4 2.1.3 CE Conformity and Labelling 4 2.1.4 EMC-Directive 2004/108/EG 5 2.1.5 Warnings 5 3 Introduction
More informationHarmonic Filtering in Variable Speed Drives
Harmonic Filtering in Variable Speed Drives Luca Dalessandro, Xiaoya Tan, Andrzej Pietkiewicz, Martin Wüthrich, Norbert Häberle Schaffner EMV AG, Nordstrasse 11, 4542 Luterbach, Switzerland luca.dalessandro@schaffner.com
More informationX Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters
Features RoHS lead-free-solder and lead-solder-exempted products are available Rugged 5 mm DIN-rail snap-fit design Class I equipment Universal AC-input with single stage conversion AC to DC or DC input
More informationPRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS
PRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS GAMATRONIC ELECTRONIC INDUSTRIES LTD. 1. Introduction Founded in 1970, Gamatronic
More informationP2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company
P2 Power Solutions Pvt. Ltd. An ISO 9001:2008 Company Quality Power within your Reach P2 Power Magnetics P2 Power Solutions Pvt. Ltd. P2 Power Solutions Pvt. Ltd. provides EMC and power quality solutions,
More informationCALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL A
1 CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL 601-339A CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL Calibration kit for EFT / Burst
More informationNew Servo Concept: Junma
New Servo Concept: Junma Junma uses the world s premier servo technology to provide unmatched performance with a quick and efficient setup. This totally new plug and play design concept requires no parameter
More information2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES
2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES Medium-voltage rack-mount power supplies Page 2 The MV2000 series high-performance, medium output
More informationSeries PCI + PIT PIT5738 U IN PIT5748 U IN PCI5748 PCI5738. Series PIT 19 - Cabinet G10
PCI + PIT PCI5728 U IN 20 32 PIT5738 U IN 40 64 PIT5748 U IN 50 80 PIT5658 U IN 80 160 PIT5678 3000VA 3000VA 3000VA 3000VA 3000VA Serie PCI5728 U IN 20 32 PCI5738 U IN 40 64 PCI5748 U IN 50 80 PCI5758
More informationCWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W
CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W FOR TESTS ACCORDING TO... > EN 300329 > EN 300340 > EN 300342-1 > EN 300386 V1.3.2 > EN 301489-1 > EN 301489-17 > EN 301489-24 > EN 301489-7 > EN 55024 > EN 61000-4-6
More informationATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW
Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationGutor PxW AC UPS Designed for North American Market
Gutor PxW AC UPS Designed for North American Market PEW 5 200 kva single phase PDW 10 220 kva three phase Higher ratings upon request schneider-electric.com 2 schneider-electric.com schneider-electric.com
More informationHarmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.
Harmonic Mitigation for Variable Frequency Drives HWEA Conference February 15, 2011 Kelvin J. Hurdle Rockwell Bus. Dev. Mgr. 1 OVERVIEW Linear vs. Non- Linear Load Definitions AC Drive Input Current Harmonics
More informationHarmonics White Paper
Harmonics White Paper New Breakthrough In PWM Drives Technology Reduces Input Line Harmonics Without the Use of Filtering Devices Harmonic Distortion Damages Equipment and Creates a Host of Other Problems
More informationObsolete Product(s) - Obsolete Product(s)
BYT 30P-1000 FAST RECOVERY RECTIFIER DIODE VERY HIGH REVERSE VOLTAGE CAPABILITY VERY LOW REVERSE RECOVERY TIME VERY LOW SWITCHING LOSSES LOW NOISE TURN-OFF SWITCHING SUITABLE APPLICATIONS FREE WHEELING
More informationB350L, 3-Way, Diverting Ball Valve Chrome Plated Brass Ball and Nickel Plated Brass Stem
B350L, 3-Way, Diverting Ball Valve hrome Plated Brass Ball and Nickel Plated Brass Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating
More informationSpecifications of ASDA A2-E_220V Series
Specifications of ASDA A2-E_220V Series Power Supply 100W 200W 400W 750W 1kW 1.5kW 2kW 3kW ASDA A2-E Series 01 02 04 07 10 15 20 30 Phase / Voltage Three-phase / Single-phase 220VAC Three-phase 220VAC
More information0.5kVA~300kVA AC POWER CORP. 400Hz Solid State Frequency Converter. Leading Test & Measurement Power Supply Provider ISO
AMF Series 00Hz Solid State Converter Ground Power Unit 0.kVA~00kVA Leading Test & Measurement Power Supply Provider R E G IS R TE D E UKAS 00 ISO 900 008 AC POWER CORP. Address: F., No.00, Gangqian Road,
More informationP2050B050, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends
pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications
More informationDale Power Solutions Ltd
DC SWITCH TRIPPER CHARGER DATASHEET Features Erskine STU 110W Range 24V, 30V, or 48VDC nominal Constant voltage current limited charger output Standard alarms LCD voltmeter LED indica ons Equipped with
More informationMeduim Voltage Drives
YANTRA HARVEST Meduim Voltage Drives YANTRA HARVEST ENERGY PVT. LTD. Office No. 101, 102, 103, Plot No. 84, Survey No. 40, Ambedkar Road, Sangamwadi, Near RTO Office, Pune - 411001 (India) Tel / Fax :
More informationB212, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem
, -Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some
More informationMD 103 ESD TargET SET USEr ManUal B
1 MD 103 ESD Target Set User Manual 601-266B MD 103 ESD Target Set User Manual MD 103 ESD target set contents 1 Safety terms and symbols 5 2 The ESD target set 6 3 Handling of the target set 7 4 Requirements
More informationDrives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)
Drives 101 Lesson 3 Parts of a Variable Frequency Drive (VFD) This lesson covers the parts that make up the Variable Frequency Drive (VFD) and describes the basic operation of each part. Here is the basics
More informationB2150VB-055, 1-1/2, V Ball Control Valve Hardened Chrome Plated Carbon Steel Body, Stainless Steel Ball and Stem
50V-055, -/, V all ontrol Valve Hardened hrome Plated arbon Steel ody, Stainless Steel all and Stem Product eatures ast quarter turn open or closed operation, Stainless steel ball and stem, Positive shut-off,
More informationP2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends
P2050005, 1/2, Pressure Independent Valve hrome Plated rass all and rass Stem, NPT emale nds pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating
More informationSHIMADEN THREE-PHASE POWER REGULATOR
SHIMADEN THREE-PHASE POWER REGULATOR SERIES PAC30Z Easy Wiring With 2-Phase Control Low-Noise Design Wide Capacity Selection (18~135A) Output Standard Feature SPECIFICATIONS Control input: Current capacity:
More informationFrequently Asked Questions (FAQs) MV1000 Drive
QUESTION 1. What is a conventional PWM Inverter? 2. What is a medium voltage inverter? 3. Are all MV inverters Voltage Source (VSI) design? 4. What is a Current Source Inverter (CSI)? 5. What output power
More informationM5028 Precision Tuned Magnetron
M5028 Precision Tuned Magnetron The data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Precision tuned pulse magnetron for linear accelerators. The tuning drive will mechanically
More informationV8 Vibration Test Systems
V8 V8 Vibration Test Systems V8-440 Shaker system: configuration and performance parameters V8-440 Metric American Armature diameter 440 mm 17.3 in Sine force peak (stabilised) 57,827 N 13,000 lbf Sine
More informationEC/AC axial fans - HyBlade Ø
E/ axial fans - Hylade Ø 00-0 version 0/0 The engineer s choice The new "little ones": axial fans with Hylade technology. The success of our Hylade series continues: xial fans with one-of-a-kind Hylade
More informationVP ELECTRONIQUE MASSY - Tel:
KEY FEATURES Switching Power Module for PCB Mountable Fully Encapsulated Plastic Case Universal Input Range 90-264VAC, 47-440 Hz Regulated Low Ripple and Noise Small Size But Higher Wattage Screw Terminal
More informationLD3985 SERIES ULTRA LOW DROP-LOW NOISE BICMOS VOLTAGE REGULATORS LOW ESR CAPACITORS COMPATIBLE
LD3985 SERIES ULTRA LOW DROP-LOW NOISE BICMOS VOLTAGE REGULATORS LOW ESR CAPACITORS COMPATIBLE INPUT VOLTAGE FROM 2.5V TO 6V STABLE WITH LOW ESR CERAMIC CAPACITORS ULTRA LOW DROPOUT VOLTAGE (100mV TYP.
More informationHIGH VOLTAGE POWER SCHOTTKY RECTIFIER
SPS817C HIGH VOLAGE POWER SCHOKY RECIFIER able 1: Main Product Characteristics I F(AV) V RRM 2 x 4 A 17 V j 175 C V F (max).74 V A1 A2 K FEAURES AND BENEFIS High junction temperature capability Low leakage
More informationAC Line EMI Suppression and RC Networks PMZ2035 Series Metallized Impregnated Paper, Class X1, 440 VAC/1,000 VDC. Applications
AC Line EMI Suppression and RC Networks PMZ2035 Series Metallized Impregnated Paper, Class X1, 440 VAC/1,000 VDC Overview The PMZ2035 Series is constructed of multilayer metallized paper encapsulated and
More informationIR Series 25TTS..FP PHASE CONTROL SCR TO-220 FULLPAK V T I TSM V RRM. 800 to 1600V < 16A = 300A. Bulletin I2135 rev.
IR Series 25TTS..FP PHASE CONTROL SCR TO-220 FULLPAK Description/Features The 25TTS..FP IR series of silicon controlled rectifiers are specifically designed for medium power switching and phase control
More informationGreen Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500
Green Scan Laser PhotocoagulatorGYC-500 Vixi Green Laser PhotocoagulatorGYC-500 The Small, Incredibly Versatile Green Laser Photocoagulator The GYC-500 Vixi / GYC-500 is a solid state green laser that
More informationHarmonic Distortion and Variable Frequency Drives
Harmonic Distortion and Variable Frequency Drives Definitions Variable Frequency Drives (VFDs); sometimes referred to as variable speed drives. Harmonic Distortion is a measure of the amount of deviation
More informationTURBO 2 ULTRAFAST HIGH VOLTAGE RECTIFIER
STTH22TV TURBO 2 ULTRAAST HIGH VOLTAGE RECTIIER MAIN PRODUCT CHARACTERISTICS I (AV) Up to 2 x 12 A V RRM 2 V T j 15 C V (typ).75 V t rr (typ) 41 ns EATURES AND BENEITS Suited for SMPS Very Low orward Losses
More information