CRoss stack LAseR GAs AnALYZeR
|
|
- Colin White
- 6 years ago
- Views:
Transcription
1 Ross stk LseR Gs nlyzer DT SHEET ross stack laser gas analyzer (ZSS) provides continuous measurement of density of Hl contained in fl ue gas in waste incineration plant and industrial waste disposal facility, NH3 in power plant and denitration equipment, O, O2, and O2 in iron and steel plant and chemical plant with high speed response. Since ZSS is installed directly on the fl ue(pipe) where objective gas fl ow to be measured, preparation is not required for measured gas to be introduced to the analyzer, which is required for sampling method. This analyzer can be used under high dust conditions, so it is possible to install upstream of the bagfi lter where gas sampling is normally diffi cult. This is the fi rst laser gas analyzer for environment and process in Japan produced by Fuji. Receiver unit ontrol unit ZSS FetuRes. Maintenance free thanks to using the long-term stable parts. 2. Running cost is minimized by no need of gas sampling devices and having few parts to replace. 3. Long and high stability due to almost no drift. 4. Since adopting the near-infrared semiconductor laser which emit light of the wavelength of measured component, hardly affected by interference of other gas.. It is suitable for injection control of slaked lime, measuring the residual ammonia gas and monitoring and control of converter furnace of combustible gas recovery due to high-speed response for to seconds.(high-speed response type: to 2 seconds) 6. It is measurable at high temperature and dust circumstance. In addition performance of dust resistance has been improved. 7. It is environment-friendly product. ecause power consumption is V or lower when V. speifitions Measurement principle: Non-dispersive infrared absorbance system (NDIR) Measuring method: ross-stack system (path system) use application: Waste incineration plant, industrial waste disposal facility, power plant iron and steel plant, paper plant, pulp mill, chemical plant and bioplant etc Light source: Near-infrared laser Laser class: lass (excluding some of O2 meters) outline (D W H) mm: Receiver unit (8 x approx.4 x approx.mm) Transmitter unit (24 x approx.4(432) x approx.6mm) ontrol unit (37 x2 x 44mm) Transmitter unit Mass: Receiver/Transmitter unit: pprox. kg ontrol unit: pprox. 8kg structure: Outdoor use type, dustproofi ng/rainproofi ng structure (IP6) ox finish color: Receiver/Transmitter box: gray ontrol unit cover: blue ontrol unit case: silver Measurable component and range: omponent Min. measuring Max. measuring range range Hl ppm ppm Hl+H2O (*) ppm (Hl) ppm (Hl) NH3 ppm ppm NH3+H2O (*) ppm (NH3) ppm (NH3) O2 (low output type) 4 vol% vol% O2 (For use in high dust) 4 vol% vol% O2 (For combustion control) 2 vol% 2 vol% O 2. vol% vol% O (For use in high temperature) vol% vol% O2 2. vol% vol% O2 (For use in high temperature) vol% vol% O+O2 2. vol% vol% O+O2 (For use in high temperature) vol% vol% H4 ppm vol% (*) Range for H2O is fi xed at vol% m. (Range in the case stack (optical path length) diameter is m) Max. and min. ranges for each stack diameter = (Max. and min. ranges when stack diameter is m) Stack diameter EDS3-3g Date Dec. 26, 22
2 ZSS * Stack diameter = Optical path length (Example: In case stack diameter is 2m for Hl measurement, Max.range: 2ppm and min. range: ppm). Material: Receiver unit / Transmitter unit: luminum, SUS36 ontrol unit: luminum Materials of gas-contacting parts: SUS36, K7, FKM, PTFE, glass-cloth, silicone ir purge connection diameter: R/4 (tube ø8 6) Power supply: Rated voltage to 24V ±% Rated frequency /6 Hz Power consumption: Max. rated power: pprox. 7V or less alibration interval: Once every six months (Maintenance cycle may vary depending on the operating environment.) Indicator (control unit): LD with back light ommunication functions: US (for loader), RS-48 (Modbus protocol) able length: Receiver unit to Transmitter unit: Standard 2m (Maximum 2m) Receiver unit to control unit: Standard m (Maximum m) nalog output: 4 to 2m D or to V D x 2 (4) Isolated output indicated in the parenthesis is optional. ( to V D, to V or to V is available.) llowable load: 4 to 2m D Ω or less, to V D kω or more (Output measurement value and O2 corresponding value. verage value and instantaneous value are switchable by the settings.) nalog input: 4 to 2m D x 2 (6) Note: Number in parenthesis is option. Measured gas pressure, measured gas temperature, measured gas velocity, O2 gas concentration, water concentration, air purge pressure (Measurement concentration correction, O2 correction or alarm output is performed according to the input signal.) ontact output: Relay contact output (contact capacity 24V D (V.)a or b (Standard: a, b: for power supply off only) Low light transmission, outside the range of upper/lower limits, device failure, during hold/during calibration, power supply off. ontact input (option): Photo coupler receiver contact input (operating voltage 2 to 24V D / to 2m) 3 verage value reset signal, switching instantaneous value/ moving average value and remote hold larm output (screen-displayed): LD failure, LD temperature error, high gas temperature, air purge (low pressure), box temperature warning, low light transmission, PD over range, connection error, I under, Range (H-Limit) or Range (L-Limit) Display contents: omponent, concentration (instantaneous value, average value O2 correction instantaneous value and O2 correction average value), alarm (fault status) contact output contents (a contact) Low light transmission: ontact output is performed (close) when the amount of light transmission is insufficient. Outside the range of upper/lower limits: ccording to the preset upper or lower limit alarm value, contact output is performed (close) when it becomes lower than alarm upper/lower limit. Device failure: ontact output is performed (close) when laser failure, laser temperature control failure, exceeding the amount of light transmission or communication error are occurred. During hold/during calibration: While O output is held by the hold setting, the values, output (close) of which is held, is the ones just before the holding or arbitrary set values. Output (close) during calibration Power supply off: Output (close) while power supply is off ontact Input ontents (option) verage value reset signal: Output of converted average value is started from the initial state by applying rectangular-wave voltage (pulse width 2 sec or more) to the input terminal of average value resetting. Output is reset by inputting and restarted by opening. Switching instantaneous value/moving average value: Switching to and from the instantaneous value and the average value of the analog output is performed by applying rectangular-wave voltage (pulse width 2 sec or more) to the input terminal for switching between the instantaneous value and the moving average values. Remote hold: The analog output is held by applying rectangular-wave voltage (pulse width 2 sec or more) to the remote hold input terminal, and restarted by applying it again. Functions O2 correction: onversion of measured Hl, NH3 and O gas concentrations into values at standard O2 concentration orrection formula: 2 On = s 2 Os : onverted concentration s:measured concentration of sample gas Os:Measured O2 concentration (Upper limit settable to 2% O2) On:Standard O2 concentration (value changeable by setting; to 9% O2) The result of calculation is indicated and output in an analog output signal. Installation Environment mbient temperature: 2 to (Receiver unit/transmitter unit), to 4 (control unit) mbient humidity: 9% R.H. or less Measurable optical path length (inner diameter of stack):. to m Standard flange: JISK flange (JIS 222) 2
3 Purge: Instrument air (compressor must be installed when power supply cannot be provided. Does not contain oil and mist). N2 for O2 meter except O2 for combustion control.pressure.mpa or more depending on measured gas velocity. Purge flow rate: 2L/min or more (depending on measured gas temperature, velocity, pressure, moisture and dust) One-side air purge flow rate: (L/min) = Gas flow rate (m/s) (in case of pipe) Measured gas condition: Temperature: 3 or less (H4, O,O2, O+O2, O2 for low output type) 4 or less (Hl) 3 to 4 (Hl+H2O) 4 or less (NH3) 3 to 4 (NH3+H2O) 2 or less (O2 for use in high dust, O for use in high temperature gas, O2 for use in high temperature gas, O+O2 for use in high temperature gas) 4 to 2 (O2 for combustion control) Pressure: ±kpa (O2 for combustion control is -kpa to kpa) Moisture: vol% or less (or Should not be saturated water vapor.) Velocity: Range of purge flow rate (gas flow rate (m/s) = one side flow rate (L/ min / ) Note) When measuring high-temperature gas at or higher, install a pressure sensor on the air-purge unit to monitor air purge. If measurement is taken while purge is not performed, the device may be damaged. Dust: to 4g/m 3 (N) (depending on environmental conditions such as measuring component, equipment specification, light path length and particle diameter). In case of high dust environment, consult with Fuji. Vibration:.G or less (.2G or less when the frequency range is 2 to 4Hz) (when optical path length is m) Mounting angle: Horizontally ± degrees or less (No dew condensation should accumulate on the window.) Performance (Except for H2O) Repeatability: ±.%FS (depending on measuring component and measuring range) Linearity: ±.%FS (depending on measuring component and measuring range) Zero drift: ±2.% FS (NH3 ±3.%, FS when range is 2ppm or less) Interference from other gas components: ±2.%FS (The gasses which have no absorption within the wavelength range of measured gas (several tens pm) do not interfere in principle). Minimum detectable limit: % of minimum detectable limit Response time (9% FS response): to seconds (high-speed type: approx. to 2seconds) Warm up time: 9 minutes or less (* Excluding influenced range with absorptive gases such as Hl and NH3) E directive compliance Low voltage safety: EN6-(2) Electromagnetic: "Installation ategory II" compatibility EN6326-(26) EN (26) EN6-3-2(26) EN6-3-3(99), (2), 2(2) asic principle Near-infrared semiconductor laser is adopted for the light source and photo-diode is adopted for photo-detection. Each measured gas component has its own wavelength range where the gas absorbs the light (see the figure below). The wavelength range consists of a set of many absorption lines, and one of these lines is used for measurement. s measurement is performed in this very narrow wavelength range, no other gas does not have an interference in principle. To detect the gas concentration, used is not a variation of light intensity, but intensity of modulated signal amplitude. 7nm nm 2nm nm 7nm 2nm 22nm Wavelength bsorption intensity O2 HF HF bsorption line used for measurement H2S NH3 H4 Hl H2S NH3 O2 NH3 bsorbing spectrum map of measuring gases 72nm 74nm 76nm 78nm 8nm 82nm 84nm bsorption lines of Hl Wavelength NO N2O N2O O 3
4 4 ZSS ODE SYMOLS When ordering, be sure to submit the order sheet on the last page of this Data Sheet. Digit Measurable components Unit Measuring range Modification No. Flange rating Number of analog output points Number of analog input points nalog output ontact output/input able length between receiver and control unit able length between receiver and transmitter Display and operation manual Measuring optical path length (unit: m) Measuring optical path length (unit:.m) Measuring optical path length (unit:.m) Dust proof specification High-speed/ G Specification O O (For use in high temperature) Hl Hl+H2O O2 O2 (For use in high temperature) O+O2 O+O2 (For use in high temperature) O2 (low output type) O2 (For use in high dust) O2 (For combustion control) H4 NH3 NH3+H2O ppm mg/m 3 vol% to 2 to 2. to 4 to to to to 2 to 2 to to to 2 to 2 to 4 to to to 2 to to 6 Others K (JIS 222) K DN/PN NSI # 2 2 points 4 points 2 points 6 points 4 to 2m D to 2m D to V D to V D to V D output points, No input output points, 3 input points m m 2m 3m 4m m 8m m Others 2m m m m 2m 2m Others Japanese English hinese ZSS Note Note Note, 2 Note Note Note 2 Note 3 Note 2, 3 Note 4 Note Note Note Note 6 Note 7 m Note 8 m 2m 3m 4m m 6m 7m 8m 9m.m Note 8.m.2m.3m.4m.m.6m.7m.8m.9m.m Note 8.m (Used only when m is specified) Standard Note 9 Dust proof Standard Note High-speed/G Y F G H K L P Q T R W X 3 K Q S L V T D J E F G H M X Y D D E F G H X D E F X J E N D N H Note ) When you order the Hl meter, O meter and NH3 meter, Specify the conversion basis of O2 concentration (settable within to 9vol% O2: Integer) Note 2) When gas temperature is or more, specify the the type for use in high temperature Note 3) Specify the same range for O and O2. If different range is desired for O and O2, specify the "X" at 6 digit and give a description of each range. Note 4) Only use where gas temperature is 4 or more Note ) Specify the range within the max/min range calculated from path length. If the range exceeds that "the measuring range x the stack length" (optical path length), consult Fuji. Note 6) Others of cable length between receiver and control unit. When specify the "X" at 4th digit, m or more is only selectable. Note 7) Others of cable length between receiver and transmitter. When specify the "X" at th digit, m or more is only selectable. Note 8) If it is m, specify the "9" at 8th digit, "9" at 9th digit and "9" at 2th digit. Note 9) Specify the "D" at 2st digit if "N" is specified at 22nd digit and use under circumstances dust is g/m 3 N) or more. Note )When "H" is specified at 22nd digit, specify the "N" at 2st digit. How to specify measuring optical path length Example: 2.2m 2 for 8th digit, 2 for 9th digit and for 2th digit m 9 for 8th digit, 9 for 9th digit and 9 for 2th digit
5 LIST FOR OMINTIONS OF MESURLE OMPONENTS, UNITS ND MESUREMENT RNGES Measurable component 4th digit Measurable range 6th digit Measurable range 6th digit (Unit: When th digit is or 3) (Unit: When th digit is ) O N/ K, Q, S, L, V,,, T,, X O (For use in high temperature) N/ V,,, T,, X H V,,, T,,,, D, J, E, F, G, H, X N/ H+H2O F,,, D, J, E, F N/ O2 G N/ K, Q, S, L, V,,, T,, X O2 (For use in high temperature) H N/ V,,, T,, X O+O2 K N/ Q, S, L, V,,, T,, X (O) N/ Q, S, L, V,,, T,, X (O2) O+O2 L N/ V,,, T,, X (O) (For use in high temperature) N/ V,,, T,, X (O2) O2(low output type) P N/ S, L, V,,, T,,, X O2(For use in high dust) Q N/ S, L, V,,, T,, X O2(For combustion control) T N/ T,,, X H4 R,, D, J, E, F, G, H, M, X K, Q, S, L, V,,, T,, X NH3 W,, T,,,, D, J, E, F, G, H, X N/ NH3+H2O X,,, D, J, E, F N/ Scope of Delivery Receiver box Transmitter box ontrol unit ngle adjustment mechanical section (required 2 units, one for receiver and the other for transmitter) able between receiver unit and transmitter unit (specified length) Optional Items Spare parts for one year (ZNSS2) alibration gas cell (*) (*2) able between receiver unit and transmitter unit (For calibration) (*) able between receiver unit and control unit (For calibration) (*) Standard gas (ZM), pressure regulator (ZD) able between receiver unit and control unit (specified length) Hexagon socket head cap screw ( onnecting bolt between angle adjustment mechanical section and receiver box) Standard accessory set, instruction manual Recorder (when necessary, Fuji's product type PHL/PHR, etc.) Others *: One set of the cables and calibration gas cell are necessary for installation and annual maintenance. *2: Standard length m (2mm or mm when the measuring range is low concentration) Standard accessories Name Quantity Specification olt 8 (6) M6 (7) SUS (*) Nut 8 (6) M6 SUS (*) Spring washer 8 (6) M6 SUS (*) Flat washer 8 (6) M6 SUS (*) ompanion flange packing or flange packing specified for use 2 ccording to flange specifications in high temperature olt for angle adjustment 6 Hex socket bolt M8 7 Power supply fuse 2 Instruction manual (*When "" or "" is specified in the 9th digit in a code symbol, quantity is 6 pieces. 8 pieces are attached in other cases.) (*When "", "" or "D" is specified in the 9th digit, olt length is 7mm. It is mm in other cases. Inch-sized bolts are not applicable.) Spare Parts for One Year (ZNSS2) Name Quantity Remarks Silicon packing 2 pieces For bellows (ZZP*ZSSTK7N38P) O-ring 2 pieces (ZZP*ZSSTK7P23P)
6 ZSS alibration/installation fixtures list (Option) Parts name Quantity Type () able between receiver unit and control unit (for calibration) ZZP*ZSSTK4J272 (2) able between receiver unit and transmitter unit (for calibration) ZZP*ZSSTK4J643 (3) alibration gas cell (*3) (Hl, NH3, O,O2, O+O2,H4) ZZP*ZSSTK4J3676 alibration gas cell (*3) (Hl+H2O, NH3+H2O, O2) ZZP*ZSSTK4J26 (4) Optical axis adjusting tool (laser pointer, target) ZZP*ZSSTK4J274 () IR card (for NH3) ZZP*ZSSTK7N4P (6) heck cell ZZP*ZSSTK4J26 (7) Filter regulator ZZP*ZSSTK7N7466P (8) Mist separator ZZP*ZSSTK7H849P (9) R/4 stopper (plug) for mist separator ZZP*ZSSTK7384P7 Flow meter (2 to L/min) (*4) ZZP*ZSSTK7N4624P () Flow meter (4 to L/min) (*4) ZZP*ZSSTK7N4624P2 Flow meter (3 to 3L/min) (*4) ZZP*ZSSTK7N8849P ir-set box (2 to L/min) ZZP*ZSSTK7N668 () ir-set box (4 to L/min) ZZP*ZSSTK7N6682 ir-set box (3 to 3L/min) ZZP*ZSSTK7N6683 ir purge mechanism (2 to L/ ZZP*ZSSTK7P433 min) (2) ir purge mechanism (4 to L/min) ZZP*ZSSTK7P4332 ir purge mechanism (3 to 3L/min) ZZP*ZSSTK7P4333 N cable for optical axis adjustment (3) ZZP*ZSSTK7P224 * 3: Standard length m (2mm or mm when the measuring range is low concentration) * 4: Usually, 2 units are required to adjust each air purge for receiver unit and transmitter unit. (3) alibration gas cell / about mm (2) able between receiver and transmitter (approx. 6mm) () able between receiver unit and control unit Stack (4) Optical axis adjusting tool (target) Parts used for calibration (4) Optical axis adjusting tool (laser pointer) Parts for adjusting the optical axis Transmitter unit () IR card IR RD Laser beam (visible) Invisible light Invisible light / visible fixtures(for NH3) Receiver unit (6) heck cell Transmitter unit Stack ontrol unit Laser gas analyzer with check cell (ZSS) SV3 tmospheric release SV SV2 (O) Sequencer Remote check input (I) N2 cylinder Standard gas cylinder Supplies for checking span value on site 6
7 () ir set box 4-φ (Mounting hole) (7) Filter regulator Parts for air purge (8) Mist separator Flow meter ox Mist separator Filter regulator Pipe with external diameter φ (out of supply scope) Receiver purge outlet Transmitter purge outlet measuring instrument air inlet Drain outlet (φ piping) (not supplied by us) () Flow meter Measuring instrument air inlet Rc/4 Piping system diagram Receiver purge outlet Rc/4 Transmitter purge outlet Rc/4 8 2 Drain outlet Piping retainer for φ (2) ir purge mechanical part total 2m m Piping material: φ8/6 Teflon pipe.m.m for φ8 tube (metallic tube recommendable) to Transmitter purge inlet to Receiver purge inlet to Receiver purge inlet Mist separator Filter regulator Measuring instrument air inlet (oupling joint) Piping system diagram (3) N cable for optical axis adjustment 7
8 ZSS OUTLINE DIGRM (Unit : mm) 2-Flowmeter (option) Or air-set box opper or SUS pipe (not supplied) Instrumentation airline joint (not supplied) φ8/6 Teflon pipe (not supplied) 2 to L/min Filter regulator (option) Instrumentation air inlet Receiver box (2 8 ) pprox. 4 Flange of angle adjustment Purging gas inlet (with bell-and-spigot joint for φ8/6) to 2 6 With bolt and nut to 2 (M6 ) Flange pipe to mount stack (not suppried) Stack Mist separator (option) pprox. 4 (432) Note Flange of angle Transmitter box adjustment (6 24 ) Purging gas inlet 2 φ. to m 6 φ34 (onnector) Receiver unit φ2 JISK FF (with packing) φ4 Transmitter unit able between receiver unit and transmitter unit (standard : 2m) 74 2-φ2 φ34 (onnector) φ ontrol unit Note : e sure to set the R/4 sealing plug (ZZP*ZSSTK7384P7) on the drain outlet of the mist separator. 42 φ3 Power supply 34 3 I7-Waterproof grand (Internal diameter φ2) able length (2mm) onnector able between receiver unit and control unit (standard : m) DI/OO74 2 Mounting diagram e sure to prepare instrument air (N2 for an O2 meter (for low output type/ high dust)). If mixed air such as oil and mist contained is used, contamination occurs in the pipe of flow meter and purge flow rate falls, which will affect the measurement. ccording to above, maintenance is required frequentlyand filter may be installed additionally depending on situation. Note) ir or nitrogen purge should be performed if the equipment is installed in a flue whether or not it is operated. n case operate the flue without performing purge, it may cause the fatal damage to the optical part. LSER GS NLYZER ZSS 8
9 EXTERNL ONNETION DIGRM (When number of analog output is 2 points) There are two types of output/input terminal. Power supply terminal 2 3 to 24 V (/6Hz) FG Screw diameter : M4 O terminal Screw diameter : M2 or the equivalent O+ 2 O- nalog output 2 O2+ 22 O2- nalog output 2 l terminal Screw diameter : M2 or the equivalent 3 I+ 4 I- nalog input 23 I4+ 24 I4- nalog input 4 (I extension board is required) I2+ 6 I2- nalog input 2 2 I+ 26 I- nalog input (I extension board is required) 7 I3+ 8 I3- nalog input 3 (I extension board is required) 27 I6+ 28 I6- nalog input 6 (I extension board is required) DI/DO terminal Screw diameter : M2 or the equivalent 9 DO DO Low light transmission 29 DO7 3 DO7 DO2 2 DO2 Device failure 3 DO8 32 DO8 Power supply off 3 DO3 4 DO3 During hold / during calibration 33 DI 34 DI verage value reset signal (option) DO4 6 DO4 Outside the range of upper / lower limits 3 DI2 36 DI2 Switching instantaneous value/moving average value (option) 7 DO 8 DO 37 DI3 38 DI3 Remote hold (option) 9 DO6 39 DI4 2 DO6 4 DI4 Note) Unassigned terminal may be connected to internal circuit. So they should not be used as repeating terminals. 9
10 ZSS External connection diagram (when number of analog output is 4 points) Power supply terminals 2 3 to 24V /6Hz FG Screws diameter: M4 O terminal O4 Unassigned Unassigned O+ 2 O- 3 O2+ 4 O2- nalog output nalog output 2 O3+ 6 O3-7 O4+ 8 O4- nalog output 3 O extension board is required) nalog output 4 O extension board is required) + - O O2 O3 I terminal I4 I I I I2 I3 I+ 2 I- 3 I2+ 4 I2- I3+ 6 I3- nalog input nalog input 2 nalog input 3 (I extension board is required) 7 I4+ 8 I4-9 I+ I- I6+ 2 I6- nalog input 4 (I extension board is required) nalog input (I extension board is required) nalog input 6 (I extension board is required) DI/DO terminal DI 2 DI 3 DI2 4 DI2 DI3 6 DI3 7 DI4 8 DI4 9 DI DI 3 DO 4 DO DO2 6 DO2 7 DO3 8 DO3 verage value reset signal (option) Switching instantaneous value/moving average value (option) Remote hold (option) Low light transmission Device failure During hold/during callibration 9 DO4 2 DO4 2 DO 22 DO 23 DO6 24 DO6 2 DO7 26 DO7 27 DO8 28 DO8 29 DO9 3 DO9 3 DO 32 DO 33 DO 34 DO Outside the range of upper/lowerlimits Power supply off Note) Unassigned terminals may be connected to internal circuit. So they should not be used as repeating terminals.
11 MOUNTING DIMENSIONS (Unit: mm) Do not install the device in a stack if air purge is not performed. It may become unusable because the window will get dirty. Stack c d a b Flange pipe to mount stack (*9) e a: Inner diameter of φmm or more b: 2 to 7mm (*) c: pproximately 2 to 2mm (*6) d: 4mm or more (*7) e: to mm (*7) Scaffold (*8) *: When used in an enviroment with high dust, reserve at least mm. *6: When internal gas temperature is high, reserve the distance of 2mm or more. Note that, adjustable angle range narrows down, so mounting angle of flange pipe to mount stack should be adjusted accurately. *7: Sufficiently secure a space for installation which permits easy operation. *8: Scaffold is required for the both side of receiver unit and transmitter unit. *9: Use a flange provided with a valve where there is a risk of gas injection or the operator may be exposed to dangerous situation. *: Tighten the flange with a torque of 8±4N-m. When tightening the flange, apply grease to the bolts (recommendable to use grease containing molybdenum). Rough guide to mount the companion flange When θ is larger than, mount it within the γ angle ( ) inside the circle with the radius. Y γ θ X Z X: Inner diameter of flange of receiver unit and transmitter unit Y: Length of flange of receiver uit and transmitter unit Z: Length of stack γ, θ = TN X 2 (Y + 2).87 (Z + Y + 2)
12 ZSS Please specify the following items when you contact us for inquiry.. ode symbol ZSS 2. Parameter of measured gas Item Min. value Typical value Max. value Measured gas concentration Temperature ( ) Pressure (kpa) Flow (m/s) Moisture (vol%) Dust (mg/m 3 (N)) Other gas component (vol%/ppm) Other gas component (vol%/ppm) Other gas component (vol%/ppm) 3. Stack diameter (Inner diameter) (measured optical path length) m 4. Length from stack (inner diameter) to flange m. Length from stack (inner diameter) to flange m 6. able between receiver unit and control unit. D m 7. able between receiver unit and transmitter unit. E m Instrumentation air Instrumentation air Stack Receiver unit Transmitter unit ontrol unit E D 8. Spares for -year measurement no need necessary 9. Optional items no need necessary.output of O2 correction value (for only Hl, NH3 and O meter) no need necessary.oxygen correction reference value (%) (When "necessary" is selected in 8) % 2.Vibration no need necessary ( G) aution on Safety *efore using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate ity Ohsaki, East Tower, -2, Osaki -chome, Shinagawa-ku, Tokyo 4-32, Japan Phone: , 728 Fax: Information in this catalog is subject to change without notice. Printed in Japan
CRoSS StACK LASeR gas ANALYZeR
DATA SHEET CRoSS StACK LASeR gas ANALYZeR (Dual beam version) Cross stack laser gas analyzer (ZSS) provides continuous measurement of CO and O2 gas concentration with fast response. Since ZSS is installed
More informationCROSS STACK LASER GAS ANALYZER
DATA SHEET CROSS STACK LASER GAS ANALYZER (Single beam version) ZSS-S Cross stack laser gas analyzer (ZSS) provides continuous measurement of density of HCl contained in fl ue gas in waste incineration
More informationCROSS STACK LASER GAS ANALYZER
DATA SHEET CROSS STACK LASER GAS ANALYZER (Single beam version) ZSS-S Cross stack laser gas analyzer (ZSS) provides continuous measurement of density of HCl contained in l ue gas in waste incineration
More informationCROSS STACK LASER GAS ANALYZER
DATA SHEET CROSS STACK LASER GAS ANALYZER (Single beam version) ZSS-S Cross stack laser gas analyzer (ZSS) provides continuous measurement of HCl contained in fl ue gas in waste incineration plants and
More informationINFRARED GAS ANALYZER
INFRRED GS NLYZER DT SHEET ZRE This gas analyzer (ZRE) is capable of measuring the concentration of NO,SO,O,O,H and O components in sample gas. NO,SO,O,O and H are measured by non-dispersion infrared method
More informationNDIR TYPE INFRARED GAS ANALYZER
DI T ID S DT ST This DI gas analyzer is used for measuring CO, CO, SO and C 4 and features a high accuracy, multiple functions and easy operation through use of a microprocessor. It is housed in a 19 inch
More informationeye in hell CD 3002 Sensor Manual
Your eye in hell CD 3002 Sensor Manual Siemens Laser Analytics AB Oct 2001 CD 3002 Sensor manual Document number: CID 3002-1102 Rev. 2A LDS 3000 Sensor manual Content Content 1. CD 3002 1 1.1 General 1
More informationOnline data sheet GM35 IN-SITU GAS ANALYZERS
Online data sheet GM35 C D E F Ordering information Type GM35 Part no. On request The exact device specifications and performance data of the product may deviate from the information provided here, and
More informationBATAILG TAIL GAS ANALYZER. Rev. 1.1
BATAILG TAIL GAS ANALYZER Rev. 1.1 The Tail Gas Analyzer is part of the BAGGI BASE Instruments Series. They are the result of combining the latest state-of-the-art-technology with over 60 years of industry
More informationINFRARED GAS ANALYZER
INFRRED GS NLYZER DT SHEET ZRE This gas (ZRE) is capable of measuring the concentration of NO,SO2,CO2,CO,CH4 and O2 components in sample gas. NO,SO2,CO2,CO and CH4 are measured by non-dispersion infrared
More informationFW100 Dust Measurement Device
product InForMAtIon FW100 Dust Measurement Device Preventing fine dust polluting the air by using scattered-light technology Analyzers and Process Instrumentation FW100 using Scattered Light Technology
More informationLA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS
SERIES Winding Wire Granular Flaw Detector Orders accepted till September, 2003 Production to be discontinued from April, 2004 Fast and reliable minute granular flaw detection in winding wires Slim Reliable
More informationIndustrial Conductivity (Electric Conductivity) Detector
Industrial Conductivity (Electric Conductivity) Detector / (General Multi-Purpose Use) R/R (Compact Ultra-Pure Water Use) S (Intrinsically Safe) The -electrode type industrial conductivity (electric conductivity)
More informationMICRO-CONTROLLER X (48mm 48mm)
PX series Digital temperature Controller DT SHEET Socket Type With front dimensions of 8 8mm, this socket type temperature controller enables OnOff control, PID control or 8step ramp/soak function, using
More informationMaxxFlow HTC Flow Measurement for Dry Bulk Solids
EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationDistance-setting Photoelectric Sensor
Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use and High Performance Hyper LED mounted. Finest pin-point beam in the industry allows detection
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationHigh Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance
1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationGeneral Specifications
General Specifications IR400 Infrared Gas Analyzer [Style : S4] The IR400 infrared gas analyzer is capable of measuring the concentrations of O, SO 2, CO 2, CO, CH 4 and O 2 components in sample gas. O,
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationHigh Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance
13 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F- Glossary of terms... P.139 Sensor selection guide... P.9~ General precautions... P.1 PHOTO PHOTO
More information} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).
ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,
More informationLED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.
99 PHOTO PHOTO LED Beam Sensor - SERIES Related Information General terms and conditions... P.1 Sensor selection guide...p.11~ / P.~ CA... P.79 ~ General precautions... P.7 Conforming to EMC Directive
More informationWDM-135A (2-wire type) WDM-136A (4-wire type) CONDUCTIVITY TRANSMITTER. Functions Features. Structure diagram. 10/ cm (note 3) 2-wire system
CONDUCTIVITY TRANSMITTR WDM-A (-wire type) WDM-6A (-wire type) It is a type of small firm aluminum -electrode site-installation CONDUCTIVITY TRANSMITTR (signal transmitter) and easy operate. The device
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationLED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.
99 PHOTO PHOTO LED Beam Sensor - SERIES Related Information General terms and conditions... P.1 Sensor selection guide...p.11~ / P.~ CA... P.79 ~ General precautions... P.7 Conforming to EMC Directive
More informationNew Developments in TDLAS NH3 Monitoring
New Developments in TDLAS NH3 Monitoring Presented by John Pisano CEMTEK Environmental UCR (University of California at Riverside) Unisearch Associates Inc Outline What is a tunable diode laser (TDL) The
More informationSPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION
ISO-400 ISO-900 SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER Model: ODM-36A FEATURES Microprocessor based 4-wire transmitter suitable for field installation. The unit features isolated inputs
More informationLOW PROFILE 2 FORM C RELAY mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.
TESTING LOW PROFILE 2 FORM RELY TQ-RELYS 9.34 26.7 +.4..2 +.6.8 4. 9.34 +.4.2 +.6.8 FETURES High sensitivity: 2 Form : 4 power consumption (single side stable type) 4 Form : 28 power consumption (single
More informationDigital batch controller
INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily
More information2 AMP. HIGH CAPACITY RELAY WITH HIGH SURGE VOLTAGE & HIGH BREAKDOWN VOLTAGE FEATURES. Characteristics. Initial breakdown voltage
TESTING 2 MP. HIGH PITY RELY WITH HIGH SURGE VOLTGE & HIGH REKDOWN VOLTGE TX-RELYS 8.4.33 FETURES reakdown voltage between contacts and coil: 2, V Surge withstand between contacts and coil: 2, V High contact
More informationOnline data sheet GMS800 EXTRACTIVE GAS ANALYZERS
Online data sheet GMS800 F H I J K L M N O P Q R S T 14181 certified US 15267 certified Ordering information Type GMS800 Part no. On request The exact device specifications and performance data of the
More informationUSER S MANUAL. EX-20 Series. Amplifier Built-in Ultra-compact Type Photoelectric Sensor
Amplifier Built-in Ultra-compact Type Photoelectric Sensor EX-20 Series USER S MANUAL WUME-EX20-3 Contens 1. Cautions 3 2. Part Description 4 3. Mounting 6 3-1 Mounting the sensor 6 3-2 Mounting to sensor
More informationInsertion Flow sensor for continuous flow measurement
Insertion Flow sensor for continuous flow measurement Economic integration into pipe systems 2 wire frequency coil (sinusoidal) version 3 wire frequency Hall effect (pulse) version to directly interface
More informationParallel Beam Linear Sensor
Parallel Beam Linear Sensor Visible Red Class II Laser Width/Profile Measurement Sensor Providing High-Speed Precision Measurement with Flexible Operation H FDA Class II IEC Class 2 visible red laser ensures
More informationULTRA LOW PROFILE 2 AMP. POLARIZED RELAY. mm inch. Initial breakdown voltage
TESTING ULTR LOW PROFILE MP. POLRIZED RELY TK-RELYS.6.47 9..34 4..7 FETURES Low profile 4 mm.7 inch height High contact capacity: Surge withstand voltage between contact and coil: V (ellcore rating) SPEIFITIS
More informationNA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation
497 Compact Size Sensor NA-PK SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.59~ Sensor selection guide... P.475~ General precautions...p.5 PHOTO PHOTO Conforming
More informationHG-C SERIES. Micro Laser Distance Sensor. Reliable detection in 10 μm precision. We offer three types of laser sensor heads for various applications
215 PHOTO PHOTO LIGHT CURTAINS / USE Micro Laser Distance Sensor SERIES Related Information General terms and conditions... F-7 Glossary of terms / General precautions.. P.1455~ / P.1458~ Sensor selection
More informationUltrasonic level transmitter, non-contact
Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:
More informationE3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features
bottle sensor Ideal for detecting transparent glass and plastic containers Features Stable operation even if container interval is shortened for higher productivity. Stable detection of 5 mm gaps that
More informationDistance-setting Photoelectric Sensor
Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use andhighperformance Hyper LED mounted. Finest pin-point beam in the industry allows detection
More informationOPTITEMP TT 20 Technical Datasheet
OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is
More informationSolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.
EN SolidFlow.0 Product Information Solid mass flow measurement SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.A Group Use SolidFlow.0 has been specially developed for measuring
More informationZ4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.
/ Length Micro Sensor LED-type Micro Sensor with Many Features in a Compact Body Compact body only /4th the volume of our previous product. % cost reduction over our previous product. High performance
More informationGS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit
High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis
More informationThermoPLUS Smart Temperature Transmitter
No. SS2-TT110-0100 ThermoPLUS Smart Temperature Transmitter Model TT61/71 (Integral Sensor type) OVERVIEW The models TT61/71 Smart Transmitter are temperature transmitters for the model TT90 integral temperature
More informationRota-Sonde DC4500. Smart display with Signal level. Easy alignment with Laser Line. Design for the most difficult applications
Scanning HOT METAL DETECTOR Rota-Sonde DC4500 Smart display with Signal level Easy alignment with Laser Line Design for the most difficult applications Very High Sensitivity 360 F Lt 1445 1 Applications
More informationLabel Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor
Ideal for Detecting Labels on Bottles Satisfies the requirements of IP67. Ensures a vibration resistance of 10 Hz to 2 khz and a shock resistance of 1,000 m/s 2 (approximately 100G). Incorporates an NPN
More informationNA DigiParts GmbH. Small / Slim Object Detection Area Sensor
953 PHOTO PHOTO MEASURE ITY Object Area Sensor General terms and conditions... F-7 Related Information Glossary of terms... P.1455~ Cross-beam scanning system to detect slim objects Letters or business
More informationRTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC
Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad
More informationUltra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor
473 PHOTO PHOTO Ultra-slim Sensor NA-PK5 SERIES SERIES General terms and conditions... F-7 Sensor selection guide... P.4~ Related Information Glossary of terms... P.455~ General precautions... P.458~ Conforming
More informationNA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects
929 PHOTO PHOTO MEASURE Object Area Sensor General terms and conditions... F-3 Related Information Glossary of terms... P.1549~ panasonic.net/id/pidsx/global guide...p.85~ General precautions... P.1552~
More informationNA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation
44 PHOTO PHOTO Compact Size Sensor NA-PK SERIES Related Information General terms and conditions... F- Glossary of terms... P.549~ guide... P.49~ General precautions...p.55~ Recognition Make sure to use
More informationSS-A5 SERIES SH SERIES
395 Manually Sensitivity Set Photoelectric Sensor SS-A5 SERIES SH SERIES Amplifi er-separated General terms and conditions... P.1 Sensor selection guide...p.11~ / P.9~ Related Information SH Specifications
More informationAbsolute Rotary Encoder EXAG Explosion Proof. Canopen
Main Features - Approval: II 2 G/D EEx d II C T6 - Heavy-duty industrial model - Interface: CAN - Protocol: - Max. 65536 steps per revolution (16 Bit) - Max. 16384 revolutions (14 Bit) - Code: Binary Programmable
More informationUFM 800 W, C Ultrasonic flowmeter for water and wastewater
KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters
More informationGeneral Specifications
General Specifications IR202 Infrared Gas Analyzer GS 11G02Q02-01EN GENERAL The IR202 infrared gas analyzer is capable of measuring concentration of CO 2, CO, CH 4, SO 2, and NO components in sample gas
More informationOVAL FLOWMETER. Meter Size: 52, 53, 55, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Magnetic coupling Outer Housing
OVAL FLOWMETER : 5, 53,, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Liquid GENERAL SPECIFICATION GS.No.GBB5E 7 GENERAL The OVAL flowmeter is a positive displacement type flowmeter
More informationE3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)
Distance-settable Photoelectric Sensor Switching between background and foreground suppression (BGS/FGS) enables detecting a variety of objects under various background/foreground conditions. Influence
More informationSF4-AH SERIES. Small Light Curtain Type 4. Compact size of mm in Type 4 light curtain ORDER GUIDE.
569 PHOTO PHOTO Small Curtain Type 4 SF4-AH SERIES Related Information General terms and conditions... P.1 SF-AC... P.588 Glossary of terms... P.983 ~ General precautions... P.986 ~ Conforming to Machine
More information6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES
6GHz Intelligent Radar Level Meter Product Manual Model:KRD520 SERIES Directory 1 Product Overview...1 2 Product Introduction...2 3 The Installation Requirements...4 4 The Electrical Connection...6 5 Instrument
More informationUltra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor
487 Ultra-slim Sensor NA-PK5 SERIES SERIES General terms and conditions... F-7 Sensor selection guide... P.475~ Related Information Glossary of terms... P.359~ General precautions... P.45 PHOTO PHOTO Conforming
More informationUltra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor
43 PHOTO PHOTO Ultra-slim Sensor NA-PK5 SERIES SERIES General terms and conditions... F-3 guide... P.49~ Related Information Glossary of terms... P.549~ General precautions... P.55~ Recognition Make sure
More informationDetector (FLS) Flow transmitter (FSV)
TIME DELT-C (FLS) transmitter (FSV) High accuracy measurement : 1.0% of rate Superior anti-bubble performance : Our dvanced M method is adopted. Maintenance free operation : Non-invasive setup with no
More informationUS-N300. Suitable for Detecting Transparent Films or Transparent Bottles ULTRASONIC SENSOR. Reliable Detection of Transparent Objects
AUDIN Composants & systèmes d'automatisme 7 bis rue de Tinqueux - 51 Reims - France Tel. +33()3264221 Fax +33()3264282 http://www.audin.fr e-mail info@audin.fr Ultrasonic Sensor Suitable for Detecting
More informationGeneral Specifications
General Specifications IR202 Infrared Gas Analyzer GS 11G02Q02-01EN GENERAL The IR202 infrared gas analyzer is capable of measuring concentration of CO 2, CO, CH 4, SO 2, and NO components in sample gas
More informationSeries 10-ZSE80/10-ISE80
Series 0-ZSE80/0-ISE80 RoHS -Color Display Digital Pressure Switch For General Fluids Directional Control Valves For positive 0 80 For vacuum/ compound 80 80F N P B R T S V Rated range Symbol -X50 Clean
More informationHBS-AP ASSEMBLING INSTRUCTIONS
ALUMINIUM PIPEWORK - ALUMINIUM PIPEWORK - ALUMINIUM PIPEWORK 97 HBS-AP ASSEMBLING INSTRUCTIONS 1. INTRODUCTION 1.1. This manual is very easy to consult and we recommend reading it before starting work,
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationM-DW1. Wafer Mapping Sensor. The safe LED beam reflective type wafer mapping sensor. Safe LEDs adopted. Sensing of nitride-coated wafers possible
915 PHOTO PHOTO OPTIS Mapping Sensor General terms and conditions... F3 Related Information General precautions... P.1552~ guide... P.865~ Recognition MEASURE CTROL panasonic.net/id/pidsx/global The safe
More informationAmplifier-separated Manual Sensitivity Setting Photoelectric Sensor
-separated Manual Sensitivity Setting Photoelectric Sensor Twin Adjuster Enables Delicate Sensitivity Setting Twin Adjuster Its twin adjuster enables easy optimum setting to suit the application. Twin
More informationManufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.
EN Manufactured by M-Sens 2 Online-Moisture Meter for Solids Product Information Moisture 13.47 % www.onthelevel.com Using M-Sens 2 is specifically designed for continuous moisture measurement of solids.
More informationNA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects. Letters or business cards detectable!
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationJUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values
JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values k For measured temperatures from -30... +260 C or -200... +600 C k For mobile or stationary temperature measurement
More informationSafety. Operating instructions Communications module ACM WAVE SYSTEM RF for gas meters with Absolute ENCODER AE2 with and without smart valve DANGER
Edition 02.10 D GB NL SK www.docuthek.com Operating instructions ommunications module AM WAVE SYSTEM RF for gas meters with Absolute ENODER AE2 with and without smart valve Translation from the German
More informationMaxxFlow HTC Flow measurement for dry bulk solids
Product Information EN MaxxFlow HTC Flow measurement for dry bulk solids SWR engineering Messtechnik GmbH envea TM a trademark of Environnement S.A Group MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Use The
More informationGC83 Digital Indicators & GC93 Digital Meter Relay
Cat.No. B- GC83 Digital Indicators & GC93 Digital Meter Relay OUTLINE Model GC83 has been designed exclusively for indication. Model GC93 is equipped with a comparator like a relay and is applied to a
More informationType PLC Fitting. Valve for Continuous control. Diaphragm valve. Output
Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationManostar Electronic Low Differential Pressure Measurement System
Manostar Electronic Low Differential Pressure Measurement System Manosys Presure Transmitter Intrinsically safe apparatus type Explosion-proof performance iag Intrinsically-safe apparatus is called by
More informationUSER S MANUAL. NX-5 Series. Power Supply Built-in Compact Multi-voltage Photoelectric Sensor
Power Supply Built-in Compact Multi-voltage Photoelectric Sensor NX-5 Series USER S MANUAL WUME-NX5-3 Contents 1. Cautions 3 2. Part description 4 3. Mounting 6 3-2 Mounting interval (thru-beam type NX5-M
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI
Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is
More informationQPM Series Indoor Air Quality Duct Sensors
Document No. CE1N1962 QPM Series Indoor Air Quality Duct Sensors Description The QPM Series Room Carbon Dioxide (CO 2 ) and Air Quality Duct Sensors are designed for applications where precise, stable
More informationGE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor
clear mode enter clear mode enter GE Sensing Introduction The GE Telaire Vaporstat 900 sensor measures in applications in the range of 0 to 0 F dew point. The sensor package is designed for wall mounting.
More informationSCHMIDT Flow Sensor SS SS FB
Product description Flow sensor with integrated microcontroller transducer for the measurement of air-flow velocity and for the determination of the flow rate and flow volume. The aerodynamically styled
More informationIS-3000 SERIES INFRARED SCANNER
IS-3000 SERIES INFRARED SCANNER NON-CONTACT, RELIABLE, PRECISE, LONG RANGE POSITIONING FOR HOT OR COLD PRODUCTS FEATURES ANALOG AND DIGITAL OUTPUTS INDICATIVE OF TARGET POSITION, WIDTH AND TEMPERATURE
More information1/16 DIN (48 48 mm) temperature controller PXR
/ DIN (8 8 mm) temperature controller PXR Features Large LED display and front waterproof structure Easy-to-see, large LED display (. times larger than current models) Easy-to-wire screw terminal design
More informationINSERTION paddle wheel flowmeter for continuous flow measurement
INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both
More informationSmart Electromagnetic Flowmeter Open channel Flowmeter Detector
No. SS2-MGN200-0200 MagneW3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIEW The MagneW3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter
More information40 mm Beam Pitch General Purpose Area Sensor. Failure monitoring
OTHER SUNX PRODUCTS NA0 SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Interference prevention Slim and intelligent Refer to p.9l for the light curtain. Slim body Failure monitoring
More informationHYBRID RECORDER OUTLINE
Specifications Sheet No.SPEC-33E (st Edition) RM0C HYRID RECORDER OUTLINE RM0C is 00mm calibrated hybrid recorder in a 44x44 DIN front panel and short depth of 50mm case housing. The recorder has versatility
More informationGeneral Specifications
General Specifications GS 11G001-01 IR400 DIR TYP IFRARD GAS AALYZR (5-MPOT AALYZR) The IR400 infrared gas analyzer is capable of measuring the concentrations of O, SO,,, C4 and O components in sample
More informationPD140FNT60QMU-02C. Through Beam. Main features. Description
Through eam Description The PD140 sensor consists of an emitter, which sends out invisible, infrared light, and a receiver, capable of detecting the light from the emitter. The sensor is encapsulated in
More informationDiode Laser Systems In Gas Measurement
Dr Roger Riley, Geotech Diode Laser Systems In Gas Measurement The application of laser diodes for improved biogas analysis Figure 2 Tuneable diode laser measurement technique Introduction The online analysis
More informationConnections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON
Heavy-duty Plug-in Photoelectric Sensor Water-resistive Photoelectric Sensor with Metal Housing & Plug-in Connector Ensuring Long Sensing Distance Satisfies the requirements of IP67, and NEMA6P. Ensures
More informationHIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES
HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE (60A type only) RELAYS A PC board type 80A Connector type 60A Screw terminal type A TM type 300A Connector type RoHS Directive compatibility
More information