1 Industrial Automation Headquarters Delta Electronics, Inc. Taoyuan Technology Center No.18, Xinglong Rd., Taoyuan District, Taoyuan City 33068, Taiwan TEL: / FAX: Asia Delta Electronics (Shanghai) Co., Ltd. No.182 Minyu Rd., Pudong Shanghai, P.R.C. Post code : TEL: / FAX: Customer Service: Delta Electronics (Japan), Inc. Tokyo Office Industrial Automation Sales Department Shibadaimon, Minato-ku Tokyo, Japan TEL: / FAX: Delta Electronics (Korea), Inc. Seoul Office 1511, 219, Gasan Digital 1-Ro., Geumcheon-gu, Seoul, South Korea TEL: / FAX: Delta Energy Systems (Singapore) Pte Ltd. 4 Kaki Bukit Avenue 1, #05-04, Singapore TEL: / FAX: Delta Electronics (India) Pvt. Ltd. Plot No.43, Sector 35, HSIIDC Gurgaon, PIN , Haryana, India TEL: / FAX : Delta Electronics (Thailand) PCL. 909 Soi 9, Moo 4, Bangpoo Industrial Estate (E.P.Z), Pattana 1 Rd., T.Phraksa, A.Muang, Samutprakarn 10280, Thailand TEL: / FAX : Delta Energy Systems (Australia) Pty Ltd. Unit 20-21/45 Normanby Rd., Notting Hill Vic 3168, Australia TEL: Americas Delta Electronics (Americas) Ltd. Raleigh Office P.O. Box 12173, 5101 Davis Drive, Research Triangle Park, NC 27709, U.S.A. TEL: / FAX: EMEA Delta Electronics (Netherlands) BV Eindhoven Office De Witbogt 20, 5652 AG Eindhoven, The Netherlands MAIL: Sales.IA.EMEA@deltaww.com MAIL: Sales.IA.Benelux@deltaww.com Delta Electronics (France) S.A. ZI du bois Chaland 2 15 rue des Pyrénées, Lisses Evry Cedex, France MAIL: Sales.IA.FR@deltaww.com Delta Electronics Solutions (Spain) S.L.U Ctra. De Villaverde a Vallecas, Dcha Ed. Hormigueras P.I. de Vallecas Madrid C/Llull, (Edifici CINC) 22@Barcrelona, Barcelona MAIL: Sales.IA.Iberia@deltaww.com Delta Electronics (Italy) Srl Ufficio di Milano Via Senigallia 18/ Milano (MI) Piazza Grazioli Roma, Italy MAIL: Sales.IA.Italy@deltaww.com Delta Electronics (Germany) GmbH Coesterweg 45, D Soest, Germany MAIL: Sales.IA.DACH@deltaww.com Delta Energy Systems LLC (CIS) Vereyskaya Plaza II, office 112 Vereyskaya str Moscow, Russia MAIL: Sales.IA.RU@deltaww.com Delta Greentech Elektronik San. Ltd. Sti. (Turkey) Serifali Mah. Hendem Cad. Kule Sok. No: 16-A Umraniye / Istanbul MAIL: Sales.IA.Turkey@deltaww.com Delta Energy Systems AG (Dubai BR) P.O. Box , Gate 7, 3rd Floor, Hamarain Centre, Dubai, United Arab Emirates MAIL: Sales.IA.MEA@deltaww.com Delta Greentech (Brasil) S/A São Paulo Office Rua Itapeva, 26 3 Andar - Bela Vista CEP: São Paulo SP - Brasil TEL: / Delta Electronics International Mexico S.A. de C.V. Mexico Office Vía Dr. Gustavo Baz No. 2160, Colonia La Loma, Tlalnepantla Estado de Mexico TEL: #3050/3052 *We reserve the right to change the information in this catalogue without prior notice. DPM-093AB /08/30

2

3

4 DPM-C501L Operation Manual Revision History Version Revision Date 1 st The first version was published. 2018/08/30

5 DPM-C501L Operation Manual Table of Contents Chapter 1 Product Introduction 1.1 Preface Overview Safety Precautions Chapter 2 Product Specifications 2.1 Electrical Characteristics Communications Operating the Display Menu Tree Dimensions Chapter 3 Installation 3.1 Installation Installation Environment Installation Notes Basic Checks Wiring Wiring Diagrams Communication Characteristics Chapter 4 Operation 4.1 General Operation Setting Menu Setups Set up the Password (PASS) Set up Communication (COM) Set up the System (SYS) Set up the Current Transformer (CT) Set up the Potential Transformer (PT) i

6 4.2.6 Set up Reset (RST) Digital Input (DI) Relay Output (RO) Edit the Password (PWD) Meter Information (INFO) Power Analysis Values Total Harmonic Distortion Measurement Chapter 5 Parameters and Funcitons 5.1 Overview of Parameters Chapter 6 Error Codes 6.1 Table of Error Codes Appendix A Accessories A.1 DCT1000 Series... A-2 A.2 DCT2000 Series... A-4 ii

7 1 Chapter 1 Product Introduction Table of Contents 1.1 Preface Overview Safety Precautions

8 DPM-C501L Operation Manual _1 1.1 Preface Thank you for choosing this product. This manual provides installation instructions for the DPM-C501L power meter. The multifunction power meter DPM-C501L is an obvious choice for any application in terms of power monitoring and control. It also can be used for measurement category CAT III. Before using the meter, read this manual carefully to ensure proper use of this meter. Before you finish reading this manual, observe the following notes. The installation environment must be free of water vapor, corrosive and flammable gas. Follow the instructions on the diagram in this manual for wiring the device. Grounding must be performed correctly and properly according to provisions for related electric work regulations currently effective in the country. Do not disassemble the meter or alter its wiring when the power is on. When the power is on, do not touch the terminal area to avoid electric shock. If you still experience issues when using the device, please contact your distributor or our customer service center. As the product is updated and improved, changes to the specifications will be included in the newest version of the manual which you can get by contacting your distributor or downloading it from the Delta Electronics website ( 1.2 Overview The DPM-C501L is equipped with a large, back-lit LCD display that displays up to four lines of information. 1-2

9 Chapter 1 Product Introduction 1.3 Safety Precautions Installation Notes 1_ Install the power meter according to instructions on the manual. Use appropriate personal protective equipment (PPE) and follow safe electrical work practices. Only qualified electrical workers should install this equipment. Such work should be performed only after reading the entire set of installation instructions. Operate the power meter according to instructions on the manual. Neglecting fundamental installation requirements may lead to personal injury as well as damage to electrical equipment or other property. This equipment should be installed in a suitable insulated and fireproof enclosure. Operation Notes DO NOT work alone. Before performing visual inspections, tests, or maintenance on this equipment, disconnect all electric power sources. Always use a properly rated sensing device to confirm that power is off. Replace all devices, doors and covers before turning on power to this equipment. Carefully inspect the work area for tools and objects that may have been left inside the equipment. Operation Notes Never short the secondary of a Power Transformer (PT). Never open circuit a Current Transformer (CT) Ensure that the CT secondary winding is fixed securely on the equipment. It may damage the equipment if the secondary winding becomes loose during operation. When used with CTs, make sure the CTs are UL2808 listed in America and Canada and meet or exceed the accuracy specifications for IEC class or accepted by authority having jurisdiction (AHJ) in other areas. Wiring Notes When the measured current is higher than the rated specification for the device, consider using an external current transformer (CT). When the measured is higher than the rated specification for the device, consider using an external potential transformer (PT) (line : 35 to 690V AC L-L or phase : 20 to 400V AC L-N). Connect only one cord to one plug on the quick connector. For the device is accidently unplugged, check the connecting cord and restart. Maintenance and Inspection Notes While cleaning the equipment, be sure to unplug all external power sources first. Use a dry cloth to clean the equipment s exterior. DO NOT open the equipment or touch the wiring inside to prevent personal injury as well as damage to electrical equipment or other property. DO NOT use aerosol sprays, solvents, or abrasives. 1-3

10 _1 DPM-C501L Operation Manual MEMO 1-4

11 2 Chapter 2 Product Specifications Table of Contents 2.1 Electrical Characteristics Communications Operating the Display Menu Tree Dimensions

12 DPM-C501L Operation Manual 2.1 Electrical Characteristics Measurement Accuracy _2 Electric quantities Voltage, current ± 0.5% Real power ± 0.5% Real power, reactive power, apparent power ± 0.5% Electric energy Reactive power ± 0.5% Power factor ± 0.5% Real power ± 0.5% Total Harmonic Distortion for Current Total Harmonic Distortion for Voltage ± 1% ± 1% Reactive power ± 0.5% Frequency ± 0.5% Apparent power ± 0.5% Harmonic ± 1% Input Voltage Connection Rated Voltage Rated Current Frequency Voltage Input 1PH2W, 1 CT 1PH3W, 2 CT 3PH3W, Δ connection, 3 CT, No PT 3PH3W, Δ connection, 2 CT, No PT Line : VAC (L-L) Phase : VAC (L-N) 1 A/5 A 50/60 Hz Measuring Category: CAT III 3PH3W, Δ connection, 3 CT, 2 PT 3PH4W, Y connection, 3 CT, No PT 3PH4W, Y connection, 3 CT, 3 PT 3PH4W, Y connection, 2 CT, 3 PT Alarm Set up multi-level alarms 10 multi-level alarms Maximum / Minimum 15/15 types With timestamp Power Operating range VAC (maximum power: 4.6 W) VDC Frequency Operating frequency 50/60 Hz Communication Mechanical Characteristics RS-485 port Dimension (W x H x D) IP Degree of Protection Modbus-RTU Baud rate 9600 / / bps 96 x 96 x 91.8 mm IP52 (front display), IP20 (meter body) 2-2

13 Chapter 2 Product Specification Environment Ambient operating temperature Storage temperature Relative Humidity C ( F) C ( F) 5 95% RH Altitude Display Below 2000 meters 2_ Screen Type Backlight LCD Blue LED Electromagnetic Compatibility Electrostatic Discharge IEC Immunity to Radiated Fields IEC Immunity to Fast Transients IEC Immunity to Impulse Waves IEC Conducted Immunity IEC Immunity to Magnetic Fields IEC Immunity to Voltage Dips IEC Radiated Emissions Conducted Emissions FCC Part 15 Class A, EN55011 Class A FCC Part 15 Class A, EN55011 Class A Harmonics IEC Flicker Emissions IEC Communications Specifications Communications RS-485 Baud rate Modbus-RTU 9600 / / bps 2-3

14 DPM-C501L Operation Manual 2.3 Operating the Display _2 A Enable / Disable H UP Key B Screen Title I DOWN Key C Load percentage J NEXT Key D Item K Operating status E Enable / disable L Unit digital input F INDEX Key M Value G BACK Key Button Basic Mode Setting Mode INDEX Key Return to the previous screen Return to the previous screen BACK Key Go to setting mode or return to the previous screen Return to the previous screen without saving the current setting UP Key Select item or page Increment the number DOWN Key Select item or page Decrement the number NEXT Key See more options Go to setting mode and go to the next setting 2-4

15 Chapter 2 Product Specification Menu Tree Display Menu Tree You can always use this button to return to HOME. PA SS HOME VLN VLL AMP P F 2_ VR VAR WATT POS + W H - W H + V A R H - V A H + V A H - V A R H THD I THD V Setting Menu Tree You can always use this button to return to HOME. PASS COM SYS CT PT RST IN FO PWD RO DI 2-5

16 DPM-C501L Operation Manual 2.4 Dimensions Front _2 Unit: mm Back: 2-6

17 3 Chapter 3 Installation Table of Contents 3.1 Installation Installation Environment Installation Notes Basic Checks Wiring Wiring Diagrams Communication Characteristics

18 DPM-C501L Operation Manual 3.1 Installation Installation Environment Keep the product in the shipping carton before installation. Store the product properly when it is not to be used for an extended period of time to retain the warranty coverage. Some storage suggestions are listed below. Store the power meter in a clean, dry, and controlled environment. Store in an ambient temperature range of C ( F). Store in a relative humidity range of 10 90%, non-condensing. _3 Do not store the product in a place subjected to corrosive gases or liquids. Place the product on a solid and durable surface. Do not mount the product near heat-radiating elements; or in a location subjected to corrosive gases, liquids, airborne dust or metallic particles; or where it can be subjected to high levels of electromagnetic radiation Installation Notes Follow the instruction when installing the product to prevent equipment breakdown. To increase the cooling efficiency, install the product with sufficient space between adjacent objects and baffles and walls to prevent poor heat dissipation. A. Voltage measurement B. Operating C. Current measurement D. RS-485 port E. Securing bracket F. DI/DO 3-2

19 Chapter 3 Installation Installation 1. This multi-functional power meter package comes with securing brackets for easier mounting and removing. 2. The mounting hole dimension is 92x92 mm (see the figure below) 3. Slide the securing bracket into the hole and then push the meter in. The maximum panel thickness should be 4.0 mm. Note: wall mount (The installation panel or cabinet surface should be flat and in good condition.) Mounting Hole Dimensions 3_ Unit: mm 3-3

20 DPM-C501L Operation Manual 3.2 Basic Checks _3 Items General Check Pre-operation Check (not supplied with power) Pre-running Check (supplied with power) Contents Regularly check for mounting looseness where the power meter and device are connected. Prevent foreign objects, such as oil, water, or metal powder entering the device through the ventilation holes. Prevent drill shavings or other debris entering the power meter. If the power meter is installed at a location with harmful gas or dust, prevent those materials from entering the power meter. Insulate the connections at the wiring terminals. Communications wiring should be done properly to prevent abnormal operations. Check for the presence of conducive and flammable objects, such as screws or metal pieces in the power meter. If electronic devices near to the power meter experience electromagnetic interference, take steps to reduce the electromagnetic interference. Check for the correct level for the power supplied to the power meter. Check if the power indicator light is lit. Check if communication between every device is normal. If there is any abnormal response from the power meter, contact your distributor or our customer service center. 3.3 Wiring Wiring Diagrams To avoid electric shock, do not change the wiring when the power is on. Install a breaker switch on the power cord for the meter because there is no power switch on the power meter. When the measured is higher than the rated specification for the device, it is necessary to use an external potential transformer (PT). When the measured current is higher than the rated specification for the device, it is necessary to use an external current transformer (CT). The following table shows the recommended wiring materials. Connecting Terminals Wire Diameters Screw Turning Torque Temperature rating Operating power Voltage Measurement Current Measurement RS-485 AWG kgf-cm (0.8 N m) above 70 C DI/DO 3-4

21 Chapter 3 Installation Connection 3PH3W, Δ connection, 3 CT, No PT 3PH3W, Δ connection, 2 CT, No PT 3_ 3PH3W, Δ connection, 3 CT, 2 PT 3PH4W, Y connection, 3 CT, No PT 3PH4W, Y connection, 3 CT, 3 PT 3PH4W, Y connection, 2 CT, 3 PT 1PH2W, 1 CT 1PH3W, 2 CT 3-5

22 DPM-C501L Operation Manual DI/DO Connection _3 The following table lists the symbols used in the diagram. Symbol Description Grounding Current transformer Terminal block Voltage transformer Fuse Communication Characteristics Communications Specifications: Max. Communication Distance Max. Connection Number Communication Protocols 1200 m Baud Rate 9600, 19200, Data Length 8 MODBUS RTU Parity None, Odd, Even Function Code 03, 06, 10 Stop Bit 1 Use shielded twisted-pair cables for RS485 communication. Connect the D+ communication terminal for all devices on the same twisted pair cable. Connect the D- terminals on the other twisted pair cable. Ground the cable shield. Install a terminal resistor on the terminal device. Use cables with a diameter of AWG. 3-6

23 4 Chapter 4 Operation Table of Contents 4.1 General Operation Setting Menu Setups Set up the Password (PASS) Set up Communication (COM) Set up the System (SYS) Set up the Current Transformer (CT) Set up the Potential Transformer (PT) Set up Reset (RST) Digital Input (DI) Relay Output (RO) Edit the Password (PWD) Meter Information (INFO) Power Analysis Values Total Harmonic Distortion Measurement

24 DPM-C501L Operation Manual 4.1 General Operation 1. Use the UP and DOWN keys to switch among setting pages. 2. Use the BACK or INDEX keys to go back to HOME page. Note 1: Use the BACK key in the HOME page to enter the setting page. Note 2: Press the NEXT key for 3 seconds in the HOME page to switch the language display between Chinese and English Setting Menu HOME page (HOME): Voltage values measured by the power meter, including THD (VT), THD current (IT), total potential transformer (PT), positive active energy (ET). Phase (VLN): Phase values measured by the power meter, including phase A _4 (AN), phase B (BN), phase C (CN) and average phase (T). Line (VLL): Line values measured by the power meter, including A-B line (AB), B-C line (BC), C-A line (CA), and average line (T). Electric current page (AMP): Electric current measured by the power meter, including phase A current (A), phase B current (B), phase C current (C) and average current (T). Power factor page (PF): Power factors measured by the power meter, including phase A (A), phase B (B), and phase C (C) power factors; and total power factor (T). Active power, reactive power, and apparent power page (PQS): Values measured by the power meter, including total active power (P), total reactive power (Q), total apparent power (S) and frequency (Hz). Active power page (WATT): Active power value measured by the power meter, including phase A (A), phase B (B), and phase C (C) active power; and total active power (T). Reactive power page (VAR): Reactive power value measured by the power meter, including phase A (A), phase B (B), and phase C (C) reactive power; and total reactive power (T). Apparent power page (VA): Apparent power value measured by the power meter, including phase A (A), phase B (B), and phase C (C) apparent power; and total apparent power (T). Positive active energy page (+WH): Positive active energy measured by the power meter, including positive active energy (PH). Reversed active energy page (-WH): Reversed active energy measured by the power meter, including reversed active energy (PH). Positive reactive energy page (+VARH): Positive reactive energy measured by the power meter, including positive reactive energy (QH). Reversed reactive energy page (-VARH): Reversed reactive energy measured by the power meter, including reserved reactive energy (QH). Positive apparent energy page (+VAH): Positive apparent energy measured by the power meter, including positive apparent energy (SH). 4-2

25 Chapter 4 Operation Reversed apparent energy page (-VAH): Reversed apparent energy measured by the power meter, including reversed apparent energy (SH). Total harmonic current distortion page (THD I): Current harmonic distortion measured by the power meter, including phase A current (A), phase B current (B), and phase C current (C) harmonic distortion; and total harmonic distortion for current (T). Total harmonic distortion page (THD I): Voltage harmonic distortion measured by the power meter, including phase A (A), phase B (B), and phase C (C) harmonic distortion; and total harmonic distortion for (T). 4.2 Setups Set up the Password (PASS) Password: You must enter the password (default 0000) before using power meter. Steps 1. Press NEXT until the first digit starts blinking. 4_ 2. Use UP and DOWN to select the first digit of the password. 3. Press ENTER to confirm the selected digit and move to set the next digit. 4. Repeat steps 2 3 to complete setting the 4-digit password. 5. After you set the 4-digit password, press ENTER to go to the parameter setting page. Note 1: If you need to edit the password setting, press BACK and the digit stops blinking. Press NEXT until the first digit starts blinking again and then follow steps 2 3 to set a new password. Note 2: Press BACK to exit the password page and go to HOME page Set up Communication (COM) Address (ID): Device ID; the address range is (default: 1); 255 is the broadcast ID. Baud Rate (BR): Transmission speed; options are 9600 kbps (default), bps, and bps. Parity setting (PA): Odd and even communication parity checking bit; options are None (8n1) (default), Even (8E1), and Odd (8o1). Steps 1. Press NEXT until the first digit starts blinking 2. Use UP and DOWN to select the device ID. 3. Press NEXT to save the setting and then set the next device ID. 4. Repeat steps 2 3 to complete setting the 3-digit device ID. Press NEXT to set the baud rate. 5. When the option starts blinking, use UP and DOWN to select the baud rate. 6. Press NEXT to save the setting and set the parity. 7. When the option starts blinking, use UP and DOWN to select the parity. 8. Press NEXT to save the setting. 4-3

26 DPM-C501L Operation Manual Note: You can go back to the previous setting item by pressing BACK anytime, whether you have completed or canceled the setting Set up the System (SYS) Wiring methods (WR): Options are one-phase two-wire (1PH2W), one-phase three-wire (1PH3W), three-phase three-wire (3PH3W), and three-phase four-wire (3PH4W); default: three-phase four-wire. Number of current transformers (CT): Options are 1, 2 and 3; default: 3. Number of potential transformers (PT): Options are 0, 2 and 3; default: 3. Steps 1. Press NEXT until the option starts blinking. 2. Use UP and DOWN to select the wiring method. _4 3. Press NEXT to save the setting and then set the number of current transformers (CT). 4. When the option starts blinking, use UP and DOWN to select the number of current transformers. 5. Press NEXT to save the setting and set the number of potential transformers (PT). 6. When the option starts blinking, use UP and DOWN to select the number of potential transformers. 7. Press NEXT to save the setting. Note: You can go back to the previous setting item by pressing BACK anytime, whether you have completed or canceled the setting Set up the Current Transformer (CT) Ampere for the primary-side current transformer; A, 5 A is default. Ampere for the secondary-side current transformer; options are 1 and 5 A; 5 A is default. Steps 1. Press NEXT until the first digit starts blinking 2. Use UP and DOWN to select the number for the primary-side current transformer. 3. Press NEXT to confirm the setting and then set the next number for the primary-side current transformer. 4. Repeat steps 2 3 to complete setting the 4-digit number for the primary-side current transformer. Press NEXT to set the secondary-side current transformer. 5. When the option starts blinking, use UP and DOWN to select the number of the secondary-side current transformer. 6. Press NEXT to save the setting. Note: You can go back to the previous setting item by pressing BACK anytime, whether you have completed or canceled the setting. 4-4

27 Chapter 4 Operation Set up the Potential Transformer (PT) Voltage for the primary-side potential transformer; V, 1 V is default. Voltage for the secondary-side potential transformer; V, 1 V is default. Steps 1. Press NEXT until the first digit starts blinking 2. Use UP and DOWN to select the number for the primary-side potential transformer. 3. Press NEXT to confirm the setting and then set the next number for the primary-side potential transformer. 4. Repeat steps 2 3 to complete setting the 5-digit number for the primary-side potential transformer. Press NEXT to set the secondary-side potential transformer. 5. When the option starts blinking, use UP and DOWN to select the number of the secondary-side potential transformer. 6. Press NEXT to confirm the setting and then set the next number for the primary-side potential transformer. 4_ 7. Repeat steps 5 6 to complete setting the 4-digit number for the primary-side potential transformer. 8. Press NEXT to save the setting. Note: You can go back to the previous setting item by pressing BACK anytime, whether you have completed or canceled the setting Set up Reset (RST) No action (none): Do not reset. Restore to defaults (def): Restore the power meter parameters to the default settings. Reset the accumulated value of electric energy (PH) on the meter to zero. Clear all detected alarm (ALA) logs on the meter. Steps 1. Press NEXT until the option starts blinking. 2. Use UP and DOWN to select the reset options. 3. Press NEXT to save the setting. Note: You can go back to the previous setting item by pressing BACK anytime, whether you have completed or canceled the setting Digital Input (DI) Digital input #1 (D1): Enable (on) or disable (off) the first digital input, default: disable (off) Digital input #2 (D2): Enable (on) or disable (off) the second digital input, default: disable (off) Digital input #3 (D3): Enable (on) or disable (off) the third digital input, default: disable (off) Digital input #4 (D4): Enable (on) or disable (off) the fourth digital input, default: disable (off) Steps 4-5

28 DPM-C501L Operation Manual 1. Press NEXT until the option starts blinking. 2. Use UP and DOWN to select ON or OFF. 3. Press NEXT to save the setting and then set the next digital input. 4. When the option starts blinking, use UP and DOWN to select ON or OFF. 5. Press NEXT to save the setting. 6. Repeat steps 4-5 to complete setting the last digital input. 7. Press NEXT to save the setting. Note: You can go back to the previous setting item by pressing BACK anytime, whether you have completed or canceled the setting Relay Output (RO) _4 Relay output#1 (R1): Enable (on) or disable (off) the first relay output; default: OFF (off) Relay output#1 (R2): Enable (on) or disable (off) the second relay output; default: OFF (off) The following table lists the relay output descriptions on the LCD. LCD display Item Description Disable This function is disabled. If the over current alarm is triggered, the Over current alarm corresponding relay closes. If the over current alarm is canceled, the corresponding relay opens. If the over line alarm is triggered, Over line alarm the corresponding relay closes. If the over line alarm is canceled, the corresponding relay open. If the under line alarm is Under line alarm triggered, the corresponding relay closes. If the under line alarm is canceled, the corresponding relay opens. If the over phase alarm is Over phase alarm triggered, the corresponding relay closes. If the over phase alarm is canceled, the corresponding relay opens. 4-6

29 Chapter 4 Operation If the under phase alarm is Under phase alarm triggered, the corresponding relay closes. If the under phase alarm is canceled, the corresponding relay opens. If the over active energy alarm is Over active energy alarm triggered, the corresponding relay closes. If the over active energy alarm is canceled, the corresponding relay Over reactive energy alarm Over apparent power alarm Over frequency alarm Under frequency alarm Digital input 1 Digital input 2 opens. If the over reactive energy alarm is triggered, the corresponding relay closes. If the over reactive energy alarm is canceled, the corresponding relay opens. If the over apparent power alarm is triggered, the corresponding relay closes. If the over apparent power alarm is canceled, the corresponding relay opens. If the over frequency alarm is triggered, the corresponding relay closes. If the over frequency alarm is canceled, the corresponding relay opens. If the under frequency alarm is triggered, the corresponding relay closes. If the under frequency alarm is canceled, the corresponding relay opens. If the digital input 1 receives a higher potential, the corresponding relay is closed. If the digital input 1 receives a lower potential, the corresponding relay is opened. If the digital input 2 receives a higher potential, the corresponding relay closes. If the digital input 1 receives a lower potential, the corresponding relay opens. 4_ 4-7

30 DPM-C501L Operation Manual If the digital input 3 receives a higher Digital input 3 potential, the corresponding relay closes. If the digital input 1 receives a lower potential, the corresponding relay opens. If the digital input 4 receives a higher Digital input 4 potential, the corresponding relay closes. If the digital input 1 receives a lower potential, the corresponding relay opens. Write 1 in Modbus register 0x594, the relay #1 closes. Write 0 in Modbus Communication register 0x594, the relay #1 opens. Write 1 in Modbus register 0x595, the _4 relay #2 closes. Write 0 in Modbus register 0x594, the relay #2 opens. Steps 1. Press NEXT until the option starts blinking. 2. Use UP and DOWN to select the setting options. 3. Press NEXT to save the setting and then set the next relay output. 4. When the option starts blinking, use UP and DOWN to select the setting options. 5. Press NEXT to save the setting. Note: You can go back to the previous setting item by pressing BACK anytime, whether you have completed or canceled the setting Edit the Password (PWD) Edit the password (default 0000) Steps 1. Press NEXT until the first digit starts blinking 2. Use UP and DOWN to select the first digit of the password 3. Press NEXT to confirm the setting and then set the next digit of the password. 4. Repeat steps 2 3 to complete setting the 4-digit password. 5. Press NEXT to save the setting. Note: You can go back to the previous setting item by pressing BACK key anytime, whether you have completed or canceled the setting. 4-8

31 Chapter 4 Operation Meter Information (INFO) Model: C501L Firmware version: 1XXXX Firmware release date: XXXXYYZZ (XXXX: year, YY: month, ZZ: day) 4.3 Power Analysis Values Total Harmonic Distortion Measurement The total harmonic distortion (THD) is a measurement of the harmonic distortion and is defined as the ratio between the power of the harmonic frequencies above the base frequency and the power of the base frequency. The total harmonic distortions for current and are calculated using the following formulas. Total Harmonic Distortion for Current 4_ Total Harmonic Distortion for Voltage 4-9

32 DPM-C501L Operation Manual MEMO _4 4-10

33 5 Chapter 5 Parameters and Functions Table of Contents 5.1 Overview of Parameters

34 DPM-C501L Operation Manual 5.1 Overview of Parameters MODBUS Address Hex Modicom Format Item Range Data Type Unit Data Size () Read (R) / Write (W) 0. System Parameters: FF Present date Date: 1 31 Week: Sun Sat Date, Week /W /W _ Present time /W Second: word Second /W Meter Constant 3200 uint P/kWh Meter Model 0: None 6: C501L word Day: uint Day Total running time of the meter Firmware version uint A Firmware release date B Date: 1 31 word Date C Reserved D Power system configuration 0: 3φ4W word /W 5-2

35 Chapter 5 Parameters and Functions 1: 3φ3W 2: 1φ2W 3: 1φ3W E Primary CT (A) uint A /W F Secondary CT (A) 0:1A 1:5A word A /W Primary PT uint V /W Secondary PT uint V /W 0: 3CT3PT 1: 3CT2PT 2: 3CT0PT 3: 2CT3PT 5_ Transformer quantities 4: 2CT2PT word /W 5: 2CT0PT 6: 1CT3PT 7: 1CT2PT 8: 1CT0PT Reserved Backlight delay 1 99 word Second /W eserved 0: Baud Rate 1: word bps /W 2: Communication mode 1: RTU word /W Data bit 0: 8 word bit /W 5-3

36 DPM-C501L Operation Manual 0: None Stop bit 1: Even word /W 2: Odd 1A Stop bit 0: 1 word bit /W 1B Modbus address word /W 0: None 1: Reset to factory default 1C Reset 2: Reset value of energy word 2 W 3: Reset alarm times 4: Reset max./min. value 1D Reserved _5 1E Reserved Alarm Over Current 1F Alarm enable 0: Disable 1: Enable word /W Pickup setpoint (current value exceeding this value triggers alarm) float A 4 R/W Reserved Dropout setpoint (current value below this value clears alarm) float A 4 R/W Alarm Over Voltage L-L Alarm enable 0: Disable 1: Enable word /W Pickup setpoint (line float V 4 R/W 5-4

37 Chapter 5 Parameters and Functions value exceeding this value triggers alarm) Reserved Dropout setpoint (line value below this value clears alarm) float V 4 R/W 3A Reserved Alarm Under Voltage L-L 3B Alarm enable 0: Disable 1: Enable word /W 3C Pickup setpoint (line value below this float V 4 R/W 3D value triggers alarm) 3E Reserved 5_ 3F Dropout setpoint (line value exceeding this value clears alarm) float V 4 R/W Reserved Alarm Over Voltage L-N Alarm enable 0: Disable 1: Enable word /W Pickup setpoint (phase value exceeding this value triggers alarm) float V 4 R/W Reserved Dropout setpoint (phase value below this value clears alarm) float V 4 R/W 5-5

38 DPM-C501L Operation Manual Reserved Alarm Under Voltage L-N Alarm enable 0: Disable 1: Enable word /W 4A Pickup setpoint (phase 4B value below this value triggers alarm) float V 4 R/W 4C Reserved 4D Dropout setpoint (phase 4E value exceeding this value clears alarm) float V 4 R/W Alarm Over Active Power _5 5E Alarm enable 0: Disable 1: Enable word /W 5F Pickup setpoint (total active power value exceeding this value triggers alarm) float kw 4 R/W Reserved Dropout setpoint (total active power value below this value clears alarm) float kw 4 R/W Reserved Over Reactive Power Alarm enable 0: Disable 1: Enable word /W Pickup setpoint (total reactive power value exceeding this value;alarm float kvar 4 R/W 5-6

39 Chapter 5 Parameters and Functions triggered) Reserved Dropout setpoint (total 6A reactive power value below this value clears alarm) float kvar 4 R/W 6B Reserved Alarm Over Apparent Power 6C Alarm enable 0: Disable 1: Enable word /W 6D Pickup setpoint (total apparent power value float kva 4 R/W exceeding this value 6E triggers alarm) 6F 4011eserved 5_ Dropout setpoint (total apparent power value below this value clears alarm) float kva 4 R/W Reserved Alarm Over Frequency AB Alarm enable 0: Disable 1: Enable word /W AC Pickup setpoint (frequency AD value exceeding this value triggers alarm) float Hz 4 R/W AE Reserved AF Dropout setpoint (frequency value below this value B clears alarm) float Hz 4 R/W 5-7

40 DPM-C501L Operation Manual B Reserved Alarm Under Frequency B Alarm enable 0: Disable 1: Enable word /W B Pickup setpoint (frequency B value below this value triggers alarm) float Hz 4 R/W B5 4018eserved B Dropout setpoint (frequency B value exceeding this value, alarm cleared) float Hz 4 R/W B Reserved _5 1. Meter Parameters: FF Phase A float V 4 R Phase B float V 4 R Phase C float V 4 R Average phase float V 4 R A B line float V 4 R 10A B B C line float V 4 R 10C C A line float V 4 R 5-8

41 Chapter 5 Parameters and Functions 10D E F Average line float V 4 R Phase A unbalance float % 4 R Phase B unbalance float % 4 R Phase C unbalance float % 4 R Phase unbalance float % 4 R A B line unbalance float % 4 R 5_ 11A B B C line unbalance float % 4 R 11C D C A line unbalance float % 4 R 11E F Line unbalance float % 4 R Phase A current float A 4 R Phase B current float A 4 R Phase C current float A 4 R 5-9

42 DPM-C501L Operation Manual Three phase average current float A 4 R Neutral line current float A 4 R 12A B Phase A current unbalance float % 4 R 12C D Phase B current unbalance float % 4 R _5 12E F Phase C current unbalance float % 4 R Current unbalance float % 4 R Total power factor (positive: lag; negative: lead) float 4 R Power factor of phase A (positive: lag; negative: lead) float 4 R Power factor of phase B (positive: lag; negative: lead) float 4 R Power factor of phase C (positive: lag; negative: lead) float 4 R 13A Total displacement power 13B factor (positive: lag; negative: lead) float 4 R 13C Total displacement power float 4 R 5-10

43 Chapter 5 Parameters and Functions 13D factor of phase A (positive: lag; negative: lead) 13E Total displacement power 13F factor of phase B (positive: lag; negative: lead) float 4 R Total displacement power factor of phase C (positive: lag; negative: lead) float 4 R Frequency float Hz 4 R Total instantaneous active power float kw 4 R Instantaneous active power 147 of phase A Instantaneous active power of phase B float kw 4 R float kw 4 R 5_ 14A Instantaneous active power of phase C 14B float kw 4 R 14C Total instantaneous 14D reactive power float kvar 4 R 14E Instantaneous reactive 14F power of phase A float kvar 4 R Instantaneous reactive power of phase B float kvar 4 R Instantaneous reactive power of phase C float kvar 4 R Instantaneous apparent float kva 4 R 5-11

44 DPM-C501L Operation Manual power Instantaneous apparent power of phase A float kva 4 R Instantaneous apparent power of phase B float kva 4 R 15A Instantaneous apparent 15B power of phase C float kva 4 R 15C Active energy of 15D three-phase delivered uint Wh 4 R _5 15E 15F Active energy of three-phase received Reactive energy of 161 three-phase delivered uint Wh 4 R uint VARh 4 R Reactive energy of three-phase received uint VARh 4 R Apparent energy of three-phase delivered uint VAh 4 R Apparent energy of three-phase received uint VAh 4 R Total harmonic distortion for float % 4 R phase A current Total harmonic distortion for float % 4 R phase B current Total harmonic distortion for float % 4 R 5-12

45 Chapter 5 Parameters and Functions phase C current 17A Total harmonic distortion for float % 4 R neutral line current 17B C Total harmonic distortion for float % 4 R phase A 17D E Total harmonic distortion for float % 4 R phase B 17F Total harmonic distortion for float % 4 R phase C Total harmonic distortion for float % 4 R 183 phase A B Total harmonic distortion for float % 4 R 185 phase B C _ Total harmonic distortion for float % 4 R phase C A Total harmonic distortion for float % 4 R current A Total harmonic distortion for float % 4 R 18B Maximum: FF Maximum A B line float V 4 R Date of maximum A B line 5-13

46 DPM-C501L Operation Manual Date: 1 31 word Date Time of maximum A B line Second: word Second Maximum B C line float V 4 R Date of maximum B C line Date: 1 31 word Date _5 20A Time of maximum B C line 20B Second: word Second 20C D Maximum C A line float V 4 R 20E Date of maximum C A line 20F Date: 1 31 word Date Time of maximum C A line Second: word Second Maximum phase A float V 4 R Date of maximum phase A Date: 1 31 word Date 5-14

47 Chapter 5 Parameters and Functions Time of maximum phase A Second: word Second Maximum phase B float V 4 R 21A Date of maximum phase B 21B Date: 1 31 word Date 21C Time of maximum phase B 21D Second: word Second 21E F Maximum phase C float V 4 R 5_ Date of maximum phase C Date: 1 31 word Date Time of maximum phase C Second: word Second Maximum phase A current float A 4 R Date of maximum phase A current Date: 1 31 word Date Time of maximum phase A 5-15

48 DPM-C501L Operation Manual current Second: word Second 22A B Maximum phase B current float A 4 R 22C Date of maximum phase B current 22D Date: 1 31 word Date 22E Time of maximum phase B current 22F Second: word Second _ Maximum phase C current float A 4 R Date of maximum phase C current Date: 1 31 word Date Time of maximum phase C current Second: word Second Maximum neutral line current float A 4 R Date of maximum neutral line current Date: 1 31 word Date 23A Time of maximum neutral line current 5-16

49 Chapter 5 Parameters and Functions 23B Second: word Second 23C D Maximum frequency value float Hz 4 R 23E Date of maximum frequency value 23F Date: 1 31 word Date Time of maximum frequency value Second: word Second Maximum total power factor float 4 R Date of maximum total power factor 5_ Date: 1 31 word Date Time of maximum total power factor Second: word Second Maximum total active power float kw 4 R 24A Date of maximum total active power 24B Date: 1 31 word Date 24C Time of maximum total active power 24D Second: word Second 5-17

50 DPM-C501L Operation Manual 24E Maximum total reactive 24F power float kvar 4 R Date of maximum total reactive power Date: 1 31 word Date Time of maximum total reactive power Second: word Second Maximum total apparent power float kva 4 R _ Date of maximum total apparent power Date: 1 31 word Date Time of maximum total apparent power Second: word Second 3. Minimum: FF Minimum A B line float V 4 R Date of minimum A B line Date: 1 31 word Date Time of minimum A B line Second: word Second 5-18

51 Chapter 5 Parameters and Functions Minimum B C line float V 4 R Date of minimum B C line Date: 1 31 word Date 30A Time of minimum B C line 30B Second: word Second 30C D Minimum C A line float V 4 R 30E Date of minimum C A line 5_ 30F Date: 1 31 word Date Time of minimum C A line Second: word Second Minimum phase A float V 4 R Date of minimum phase A Date: 1 31 word Date Time of minimum phase A Second: word Second Minimum phase B float V 4 R 5-19

52 DPM-C501L Operation Manual A Date of minimum phase B 31B Date: 1 31 word Date 31C Time of minimum phase B 31D Second: word Second 31E F Minimum phase C float V 4 R _ Date of minimum phase C Date: 1 31 word Date Time of minimum phase C Second: word Second Minimum phase A current float A 4 R Date of minimum phase A current Date: 1 31 word Date Time of minimum phase A current Second: word Second 32A Minimum phase B current float A 4 R 32B

53 Chapter 5 Parameters and Functions 32C Date of minimum phase B current 32D Date: 1 31 word Date 32E Time of minimum phase B current 32F Second: word Second Minimum phase C current float A 4 R Date of minimum phase C current Date: 1 31 word Date Time of minimum phase C current 5_ Second: word Second Minimum neutral line current float A 4 R Date of minimum neutral line current Date: 1 31 word Date 33A Time of minimum neutral line current 33B Second: word Second 33C D Minimum frequency value float Hz 4 R 33E Date of minimum frequency 5-21

54 DPM-C501L Operation Manual value 33F Date: 1 31 word Date Time of minimum frequency value Second: word Second Minimum total power factor float 4 R Date of minimum total power factor Date: 1 31 word Date _ Time of minimum total power factor Second: word Second Minimum total active power float kw 4 R 34A Date of minimum total active power 34B Date: 1 31 word Date 34C Time of minimum total active power 34D Second: word Second 34E Minimum total reactive 34F power float kvar 4 R Date of minimum total reactive power 5-22

55 Chapter 5 Parameters and Functions Date: 1 31 word Date Time of minimum total reactive power Second: word Second Minimum total apparent power float kva 4 R Date of minimum total apparent power Date: 1 31 word Date Time of minimum total apparent power Second: word Second 5_ 4. Alarm: FF 0: Cleared Alarm status of over current 1: Triggered word Alarm times of over current word times Alarm date of over current Date: 1 31 word Date Alarm time of over current Second: word Second Alarm status of over line 0: Cleared 1: Triggered word Alarm times of over line word times 5-23

56 DPM-C501L Operation Manual Alarm date of over line Date: 1 31 word Date Alarm time of over line Second: word Second Alarm status of under line 0: Cleared 1: Triggered word Alarm times of under line word times _5 41A Alarm date of under line 41B Date: 1 31 word Date 41C Alarm time of under line 41D Second: word Second 41E Alarm status of over phase 0: Cleared 1: Triggered word 41F Alarm times of over phase word times Alarm date of over phase Date: 1 31 word Date Alarm time of over phase 5-24

57 Chapter 5 Parameters and Functions Second: word Second Alarm status of under 0: Cleared 1: Triggered word Alarm times of under phase word times Alarm date of under phase Date: 1 31 word Date Alarm time of under phase Second: word Second 5_ Alarm status of over active energy 0: Cleared 1: Triggered word Alarm times of over active energy word times Alarm date of over active energy Date: 1 31 word Date 43A Alarm time of over active energy 43B Second: word Second 43C Alarm status of over reactive energy 0: Cleared 1: Triggered word 43D Alarm times of over reactive word times energy 5-25

58 DPM-C501L Operation Manual 43E Alarm date of over reactive energy 43F Date: 1 31 word Date Alarm time of over reactive energy Second: word Second Alarm status of over apparent power 0: Cleared 1: Triggered word Alarm times of over apparent power 1, 255 word times _ Alarm date of over apparent power Date: 1 31 word Date Alarm time of over apparent power Second: word Second Alarm status of power factor (lead) 0: Cleared 1: Triggered word Alarm times of power factor 1, 255 word times (lead) 47A Alarm date of power factor (lead) 47B Date: 1 31 word Date 47C Alarm time of power factor (lead) 5-26

59 Chapter 5 Parameters and Functions 47D Second: word Second 47E Alarm status of power factor (lag) 0: Cleared 1: Triggered word 47F Alarm times of power factor word times (lag) Alarm date of under frequency Date: 1 31 word Date Alarm time of under frequency Second: word Second 5. Advanced Settings: FF 5_ 50C Setting group 1 0x100 0x1E7 word /W 50D Setting group 2 0x100 0x1E7 word /W 0x100 0x1E7 word /W Setting group 10 0x100 0x1E7 word /W Reset energy date Reset energy date Date: 1 31 word Date Reset energy time Reset energy time Second: word Second Setting of digital input #1 0: Disable 1: Enable word /W Setting of digital input #2 0: Disable word /W 5-27

60 DPM-C501L Operation Manual 1: Enable 58A Setting of digital input #3 0: Disable 1: Enable word /W 58B Setting of digital input #4 0: Disable 1: Enable word /W Alarms: 0: Disable 1: Over current 2: Over line 58C Setting of relay output #1 3: Under line 4: Over phase word /W _5 5: Under phase 6: Over active energy 7: Over reactive energy 8: Over apparent power 9: Over frequency 10: Under frequency 11: Digital input #1 12: Digital input #2 13: Digital input #3 58D Setting of relay output #2 word /W 14: Digital input #4 15: Communication (when set for Relay Output #1, register 0x594 is writable) (when set for Relay Output #2, register 0x595 is writable) Status of digital input #1 0: Low word 5-28

61 Chapter 5 Parameters and Functions 1: High 255: Disable 0: Low Status of digital input #2 1: High word 255: Disable 0: Low Status of digital input #3 1: High word 255: Disable 0: Low Status of digital input #4 1: High word 255: Disable 0: Open 5_ Status of relay output #1 1: Closed Note: register 0x58C can only be written when the value is set to 15 word /W 0: Open Setting of relay output #2 1: Closed Note: register 0x58D can only be written when the value is set to 15 word /W 6. Parameter Group: FF Read data from group Read data from group Read data from group

62 DPM-C501L Operation Manual MEMO _5 5-30

63 6 Chapter 6 Error Codes Table of Contents 6.1 Error Codes

64 DPM-C501L Operation Manual 6.1 Error Codes When an error occurs during operation, the power monitor sends an error code through Modbus. The following table lists the error codes and causes. Error Code Name Description 0x01 Illegal function Incorrect function code 0x02 Illegal data address Incorrect data address to read or write 0x03 Illegal data value Incorrect data format (for example, data length) 0x04 Slave device failure Slave cannot execute the command

65 12 A Appendix A Accessories Table of Contents A.1 DCT1000 Series...A-2 A.2 DCT2000 Series...A-4 A-1

66 DPM-C501L Operation Manual When measured current is higher than the rated specification for the device, use of an external current transformer (CT) is necessary. A.1 DCT1000 Series Electromagnetic Compatibility: CE-marking, IEC Model Number Measurement Accuracy Primary Current Secondary Current Rated Burden (VA) External Dimension*1 (mm) Size of Opening*1 (mm) DCT-S301C 1.0% 100 A 5 A 1.5 DCT-S211C 0.5% 200 A 5 A 1 DCT-S221C 0.5% 300 A 5 A x 40 x x 32 DCT-S231C 0.5% 400 A 5 A 2.5 DCT-S241C 0.5% 500 A 5 A 2.5 DCT-S251C 0.5% 600 A 5 A 2.5 DCT-S261C 0.5% 750 A 5 A x 52 x x 80 DCT-S271C 0.5% 1000 A 5 A 5 _A DCT-S281C 0.5% 1500 A 5 A 7.5 DCT-S291C 0.5% 2000 A 5 A x 51.6 x x 122 DCT-S2A1C 0.5% 2500 A 5 A x 52 x x DCT-S2B1C 0.5% 3000 A 5 A 20 *1: See the following table for detailed information on the external dimensions and sizes of opening. A-2

67 Appendix A Accessories Model Number Dimension (mm) DCT-S301C DCT-S211C External Dimension: 90 x 40 x 111 Size of Opening: 21 x 32 DCT-S221C DCT-S231C DCT-S241C DCT-S251C External Dimension: x 52 x 147 Size of Opening: 50 x 80 DCT-S261C DCT-S271C External Dimension: A_ x 51.6 x 198 Size of Opening: 80 x 122 DCT-S281C A-3

68 DPM-C501L Operation Manual DCT-S291C External Dimension: x 52 x 252 Size of Opening: DCT-S2A1C 81 x DCT-S2B1C A.2 DCT2000 Series Electromagnetic Compatibility: UL, UL2808. Model Number Measurem ent Accuracy Primary Current Secondary Current Rated Burden (VA) External Dimension*1 (mm) Size of Opening*1 (mm) DCT-S201B 1.0% 100 A 5 A 1 DCT-S211B 0.5% 200 A 5 A 1 90 x 40 x x 30 _A DCT-S221B 0.5% 300 A 5 A 1.5 DCT-S231B 0.5% 400 A 5 A 1.5 DCT-S241B 0.5% 500 A 5 A 2.5 DCT-S251B 0.5% 600 A 5 A 2.5 DCT-S261B 0.5% 750 A 5 A x 57 x x 80 DCT-S2C1B 0.5% 800 A 5 A 3.75 DCT-S271B 0.5% 1000 A 5 A 5 *1: See the following table for detailed information on the external dimensions and sizes of opening. A-4

69 Appendix A Accessories Model Number Dimension (mm) External Dimension: DCT-S201B 90 x 40 x 110 Size of Opening: DCT-S211B 20 x 30 DCT-S221B DCT-S231B DCT-S241B DCT-S251B External Dimension: 115 x 57 x 158 Size of Opening: 50 x 80 DCT-S261B DCT-S2C1B DCT-S271B A_ A-5

Delta Electronics (France) S.A. ZI du bois Chaland 2 15 rue des Pyrénées, Lisses Evry Cedex, France MAIL:

Delta Electronics (France) S.A. ZI du bois Chaland 2 15 rue des Pyrénées, Lisses Evry Cedex, France MAIL: Industrial Automation Headquarters Delta Electronics, Inc. Taoyuan Technology Center No.18, Xinglong Rd., Taoyuan District, Taoyuan City 33068, Taiwan TEL: 886-3-362-6301 / FAX: 886-3-371-6301 Asia Delta

More information

Delta Din-rail Power Meter DPM-D520I User Manual.

Delta Din-rail Power Meter DPM-D520I User Manual. Delta Din-rail Power Meter DPM-D520I User Manual www.deltaww.com Table of Content 1. Preface 4 2. Notes 5 2.1 Safety Notes 5 2.2 Installation Environment 6 3. Descriptions of Parts 7 3.1 Operating Interface

More information

Multi-functional Power Meter DPM-C530A User Manual.

Multi-functional Power Meter DPM-C530A User Manual. Multi-functional Power Meter DPM-C530A User Manual www.deltaww.com Table of Contents 1. Preface 2 2. Notes 3 2.1 Safety Notes 3 2.2 Installation Environment 4 3. Descriptions of Parts 5 3.1 Operating Interface

More information

Delta Door Control Drive & Motor VFD-DD Series. Automation for a Changing World. Delta presents you with an ideal drive for door applications

Delta Door Control Drive & Motor VFD-DD Series. Automation for a Changing World. Delta presents you with an ideal drive for door applications Delta presents you with an ideal drive for door applications Automation for a Changing World Delta Door Control Drive & Motor VFD-DD Series www.deltaww.com Door Drive Functions and Features User Friendly

More information

Specifications of ASDA A2-E_220V Series

Specifications of ASDA A2-E_220V Series Specifications of ASDA A2-E_220V Series Power Supply 100W 200W 400W 750W 1kW 1.5kW 2kW 3kW ASDA A2-E Series 01 02 04 07 10 15 20 30 Phase / Voltage Three-phase / Single-phase 220VAC Three-phase 220VAC

More information

Delta Power Meter DPM Series

Delta Power Meter DPM Series utomation for a Changing World Delta Power Meter DPM Series www.deltaww.com Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power quality parameters, including

More information

Delta Elevator Drive ED Series

Delta Elevator Drive ED Series Automation for a Changing World Delta Elevator Drive ED Series www.deltaww.com Elevator Drive - ED Series Delta introduces its new elevator control solution: the Elevator Drive ED Series. Developed with

More information

Delta Power Meter DPM Series

Delta Power Meter DPM Series utomation for a hanging World Delta Power Meter DPM Series www.deltaww.com Product Introduction Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power quality

More information

Delta Power Meter DPM Series

Delta Power Meter DPM Series utomation for a hanging World Delta Power Meter DPM Series www.deltaww.com Product Introduction Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power quality

More information

ZHUHAI PILOT TECHNOLOGY CO., LTD.

ZHUHAI PILOT TECHNOLOGY CO., LTD. SPM32 Multifunctional Power Meter SPM32 Multifunction Power Meter Installation & Operation Manual V1.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals.

More information

Delta Power Meter DPM Series

Delta Power Meter DPM Series utomation for a hanging World Delta Power Meter DPM Series www.deltaww.com Product Introduction Delta's Multifunction Power Meter DPM Series precisely measures various electrical energy and power quality

More information

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required

More information

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet IMA 1000 Watts Power Supply Series for medical and industrial applications Product data sheet Features 1000 Watts Power Supply Series for medical and industrial applications Safety rated for Medical, Industrial

More information

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter SDM630MCT-RJV-333mV SDM630MCT-RJA-00mA Three phase multifunction din rail energy meter Plug-in solution; labor saving; wiring mistake free Measures kwh KVarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.

More information

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product data sheet IMA 600 Watts Power Supply Series for medical and industrial applications Product data sheet 600 Watts Power Supply Series for medical and industrial applications Features Safety rated for Medical, Industrial

More information

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet IMA 400 Watts Power Supply Series for medical and industrial applications Product data sheet 400 Watts Power Supply Series for medical and industrial applications Features Safety rated for Medical, Industrial

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

Delta IP55 Fan and Pump Drive CFP2000 Series

Delta IP55 Fan and Pump Drive CFP2000 Series Automation for a Changing World Delta IP55 Fan and Pump Drive CFP2000 Series www.deltaww.com CFP2000 Delta's CFP2000 series is an AC motor drive specially designed for HVAC, fans & pumps, a IP55 enclosure

More information

PEM353. Universal measuring device

PEM353. Universal measuring device 353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities

More information

Delta Smart Sensor

Delta Smart Sensor Automation for a Changing World Delta Smart Sensor www.deltaww.com Flat Type: easy to install in any conditions Rectangular Type: one-turn screw for distance setting High chemical resistance in all models

More information

Installation Instructions and Reference Handbook. Installation instructions

Installation Instructions and Reference Handbook. Installation instructions Installation Instructions and Reference Handbook Multi-instrument MIB 7000/7000C/7020 4189320016B (UK) DEIF A/S Product information Installation instructions Basic operation DEIF A/S, Frisenborgvej 33

More information

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output. Power analyzers and Energy Meters Multifunction indicator Type WM12-96 Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

Power Meter Series PM3200 Functions and characteristics

Power Meter Series PM3200 Functions and characteristics Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring

More information

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM] Feature Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High

More information

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Energy Meter Type EM21 72R Retro-Fit Energy Management Energy Meter Type EM21 72R Retro-Fit Including 3 miniature split-core current sensors 10mm (90A), 16mm (150A) and 24mm (250A) diameter holes Class A (kwh) according to EN50470-3 Class

More information

Operating Guide October 2006

Operating Guide October 2006 Operating Guide October 2006 Safety 1 Safety This manual represents your meter as manufactured at the time of publication. It assumes standard software. Special versions of software may be fitted, in which

More information

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID Professionally approved products. Datasheet Stock Number: 144-0527 3 Phase Multi-function Power Meter 1/5A MID 96mm² Panel Mounted Power Meter. MID UK Specifications The 144-0527 is a new generation modern

More information

Energy Management Energy Analyzer Type EM210 MID

Energy Management Energy Analyzer Type EM210 MID Energy Management Energy Analyzer Type Multi-use housing: for both DIN-rail and panel mounting applications MID annex MI-003 (Measuring Instruments Directive) compliant Class B (kwh) according to EN50470-3

More information

MU110-16R(K) Digital output module 16 channel. User guide

MU110-16R(K) Digital output module 16 channel. User guide MU110-16R(K) Digital output module 16 channel User guide MU110-16R(K)_2016.12_0220_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany

More information

Delta Temperature Controller DT Series

Delta Temperature Controller DT Series Automation for a Changing World Delta Temperature Controller DT Series www.deltaww.com Features Many Sizes Available: From 48x24 mm to 96x96 mm, all panel sizes comply with international standards Quality

More information

SUPPLY NETWORK ANALYZER CVM-96 SERIES

SUPPLY NETWORK ANALYZER CVM-96 SERIES SUPPLY NETWORK ANALYZER CVM-96 SERIES (Power Demand) INSTRUCTION MANUAL ( M 981 326 / 00B - GB) (c) CIRCUTOR S.A. ----- Supply network analyzer CVM-96 ------ User's manual --- Page No. 1 CVM-96 SUPPLY

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Power analyzers and Energy Meters Power Analyzer Type WM14-96 Power analyzers and Energy Meters Power Analyzer Type WM14-96 Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3 CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2

More information

ME432 Three-phase Power Meter

ME432 Three-phase Power Meter ME432 Three-phase Power Meter Connectivity advantages MODEL ME432 Support Extra sensor Programmable digital output I/O function 333mV CT Rogowski coil Relay 1*digital output Power 85~265V AC/DC 1 Feature

More information

3-phase meter with direct connection and pulse or Modbus RS485 output

3-phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 3-phase meter with direct connection and CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

ULTRA RAPID POWER QUALITY ANALYZER

ULTRA RAPID POWER QUALITY ANALYZER ULTRA RAPID POWER QUALITY ANALYZER Ultra rapid (cycle by cycle) advanced electrical network analysis Complete network harmonics analysis, up to 63 rd harmonic High visibility, 5 graphic LCD screen with

More information

Energy Management Energy Analyzer Type EM210

Energy Management Energy Analyzer Type EM210 Energy Management Energy Analyzer Type EM210 Multi-use housing: for both DIN-rail and panel mounting applications Current inputs AV option: CT 5A Current inputs MV option: current sensor 333 mv (CTV series)

More information

Delta Power Meter DPM Series

Delta Power Meter DPM Series utomation for a hanging World Delta Power Meter DPM Series www.deltaww.com Product Introduction Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power qual

More information

ASCO 5210 Digital Power Meter. Operator s Manual DANGER

ASCO 5210 Digital Power Meter. Operator s Manual DANGER Operator s Manual ASCO 5210 Digital Power Meter TABLE OF CONTENTS section-page INTRODUCTION General Information... 1-1 Measurements... 1-2 Specifications... 1-3 Device Ratings... 1-4 INSTALLATION Mounting...

More information

MU110-8R(K) Digital output module 8 channel. User guide

MU110-8R(K) Digital output module 8 channel. User guide MU110-8R(K) Digital output module 8 channel User guide MU110-8R(K)_2019.01_0296_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany

More information

Installation and Operating Instructions

Installation and Operating Instructions Energy Division Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Our commitment. Your advantage. Contents Page 1 Introduction 4 1.1 Measurement Capabilities 5 1.2

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN Energy Management Energy Meter Type EM33 DIN Easy connections management Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X):

More information

C u t l e r- H a m m e r. IQ Analyzer START Q U I C KS TA RT G U I D E

C u t l e r- H a m m e r. IQ Analyzer START Q U I C KS TA RT G U I D E C u t l e r- H a m m e r IQ Analyzer START Q U I C KS TA RT G U I D E C O N T E N T S Introduction 4 Mounting 9 IMPORTANT NOTICE Use this Guide to begin performing basic metering functions quickly, without

More information

Centrale de mesure Power Meter PM500 Merlin Gerin

Centrale de mesure Power Meter PM500 Merlin Gerin Notice d'installation et d'utilisation Installation and user manual Centrale de mesure Power Meter PM500 Merlin Gerin 059473_D Introduction and description Package contents c one PM500 power meter with

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Power analyzers and Energy Meters Multifunction indicator Type WM12-DIN Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

MultiCube Multi-Function Electricity Meter. Installation and Operation

MultiCube Multi-Function Electricity Meter. Installation and Operation MultiCube Multi-Function Electricity Meter Installation and Operation PREFACE MultiCube Operating Guide Revision 1.08 Jan 2007 This manual represents your meter as manufactured at the time of publication.

More information

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

SC-225/SC-250/SC-325/SC-350 STATIC CONTACTOR

SC-225/SC-250/SC-325/SC-350 STATIC CONTACTOR Safety Provisions Do not open the device enclosure. There are no user-servicable parts inside the device enclosure. Ensure that the earth connection of the device is done..!! Warning: Consider that there

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

Monitoring Electric Network Via Internet

Monitoring Electric Network Via Internet Monitoring Electric Network Via Internet NETWORK ANALYSER let "it" analyse! MPR63 Real time monitoring via internet / intranet Measurement of all electrical parameters Including Harmonics Automatic recording

More information

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

ENA33LCD. Power line analyzer. User and service manual.   Obrezija 5 SI-1411 Izlake ENA33LCD Power line analyzer User and service manual version 2.9 (FW version 6.8 and newer) ETI, d.o.o. Obrezija 5 SI-1411 Izlake www.etigroup.eu/products-services 1. Front control panel and terminal plate

More information

VIP Current & Power Multimeter

VIP Current & Power Multimeter VIP Current & Power Multimeter Rev 1.6 Table of Contents 1. Mechanical Installation... 3 2. Wiring diagram... 4 3. Specifications... 5 Technical Specifications... 5 3.2 Measuring Specifications... 5 4.

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

MANUAL PCE-UT232

MANUAL PCE-UT232 www.pce-group-europe.com PCE- Deutschland Gmb H & Co. KG Tel: +49 029 03 976 99-0 Fax: +49 029 03 976 99-29 info@warensortiment.de www.warensortiment.de PCE Group Ibérica S.L. Tel: +34 967 543 548 Fax:

More information

Delta Power Meter DPM Series

Delta Power Meter DPM Series utomation for a hanging World Delta Power Meter DPM Series www.deltaww.com Product Introduction Delta's Multifunction Power Meter DPM Series precisely measures various electrical energy and power quality

More information

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT

More information

User Guide for Tool Turrets

User Guide for Tool Turrets Industrial Automation Headquarters Delta Electronics, Inc. Taoyuan Technology Center No.18, Xinglong Rd., Taoyuan City, Taoyuan County 33068, Taiwan TEL: 886-3-362-6301 / FAX: 886-3-371-6301 Asia Delta

More information

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

UT232. Operating Manual. Digital Power Clamp Meter

UT232. Operating Manual. Digital Power Clamp Meter UT232 Operating Manual Digital Power Clamp Meter Model UT232 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical

More information

Phase-sequence Phase-loss Relay

Phase-sequence Phase-loss Relay Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Prevents reverse motor rotation due to incorrect wiring. Distinguishes between positive

More information

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads Fluke 345 Power Quality Clamp Meter Technical Data The ideal meter for commissioning and troubleshooting modern electrical loads With a bright color display to analyze the harmonic spectrum, a low-pass

More information

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse

More information

Energy Management Energy Analyzer Type EM270-72D

Energy Management Energy Analyzer Type EM270-72D Energy Management Energy Analyzer Type EM270-72D RS485 dual port for daisy chain connection (optional) 2 programmable pulsating outputs (optional) Easy connections management (selectable) disabled by default

More information

Energy Management Energy Meter GM3T E GM3T-RS485 E

Energy Management Energy Meter GM3T E GM3T-RS485 E Energy Management Energy Meter GM3T E09 814 96 GM3T-RS485 E09 816 65 Certified according to MID Directive Product Description Three-phase energy meter with removable front LCD display unit. The same unit

More information

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN Energy Management Energy Meter Type EM23 DIN Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X): see how to order on the next

More information

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port Viale Borri 231, 21100 Varese Italy Multifuncion Measuring Device, 4 mod. Contents Pages 1. Description Use... 2 2. Range... 2 3. Overall dimensions... 2 4. Preparation Connection... 2 5. General characteristics...

More information

Energy Management Energy Analyzer Type EM280-72D

Energy Management Energy Analyzer Type EM280-72D Energy Management Energy Analyzer Type EM280-72D Equivalent to Class 1 (kwh) of EN62053-21 (EM280 base only) Equivalent to Class 2 (kvarh) of EN62053-23 (EM280 base only) Virtual meter (sum of two 3-phase

More information

UMG 96RM Basic Device

UMG 96RM Basic Device Smart Energy & Power Quality Solutions Power Analyser Basic Device Data sheet Dok.-Nr. 2.040.172.0 02/2019 DEVICE VIEWS Front view Rear view Side view Bottom view max. 6 96 91,5 104 91,5 97 42 Cut-out

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

MV110-8AS. Analog input module 8 channel. User guide

MV110-8AS. Analog input module 8 channel. User guide MV110-8AS Analog input module 8 channel User guide MV110-8AS_2016.12_0226_EN All rights reserved Subject to technical changes and misprints Contents 1 Description... 2 1.1 Function... 2 1.2 RS485 network...

More information

HAWK5000 Operators Manual

HAWK5000 Operators Manual HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED

More information

Conzerv EM6400NG series

Conzerv EM6400NG series Conzerv EM6400NG series Multi-function power & energy meters Technical datasheet PB115131 Introducing EM6400NG, next generation power meters of iconic EM6400 series with innovative Accurate measurements

More information

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

Electrical network management. Schneider Electric. PM3200 Technical Datasheet Electrical network management Schneider Electric PM3200 Technical Datasheet Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact

More information

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Tyco Electronics UK Limited Crompton Instruments Freebournes Road, Witham, Essex, CM8 3AH, UK Tel: +44 1376 509 509

More information

Model UT233 OPERATING MANUAL

Model UT233 OPERATING MANUAL Model UT233 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure A. The Meter Front

More information

Multifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU

Multifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU Multifunction network analyzer Q15U2... - Q96U2L - Q96U4... Q15E2... - Q96E2... - MCU - MCUH Programmable transducer MCUU OPERATING MANUAL Ipm0163.8 - Edition 06.09 Langer Messtechnik GmbH Soyerhofstrasse

More information

AMIK 200 / 201 Technical Data Sheet

AMIK 200 / 201 Technical Data Sheet AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT

More information

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13 INSTALLATION MANUAL Model: Smart Analyzer Manufacturer: Smart Impulse Power meter with consumption breakdown by use 03/12/13 Table of contents Table of contents... 2 1. Introduction... 3 2. Installation

More information

Installation & Operation Manual ELNet VIP

Installation & Operation Manual ELNet VIP Installation & Operation Manual ELNet VIP Electrical Measurements Table of Contents 1. Mechanical Installation... 1-3 2. Wiring diagram... 2-5 3. Specifications... 3-6 Technical Specifications... 3-6 Measuring

More information

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications Energy Management Multifunction indicator Type WM12-DI Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase measurements:

More information

PLA 33. Power line analyzer. User and service manual. version 2.4

PLA 33. Power line analyzer. User and service manual. version 2.4 PLA 33 Power line analyzer User and service manual version 2.4 Content. Front control panel and terminal plate...3 7.2.2. System frequency setting...0 2. Device description...4 7.2.3. Password protection...0

More information

312, 316, 318. Clamp Meter. Users Manual

312, 316, 318. Clamp Meter. Users Manual 312, 316, 318 Clamp Meter Users Manual PN 1989445 July 2002 Rev.2, 2/06 2002, 2006 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies.

More information

PMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD.

PMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. PMAC770 Multifunction Power Meter Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals. The manufacturer shall not

More information

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A. SUPPLY NETWORK ANALYZER CVMk SERIES & CVMk-4C SERIES INSTRUCTION MANUAL ( M 981 171 / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A. ----- Supply network analyzer CVMk and CVMk-ITF ------ Manual 1 / 2 --- Page

More information

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming Energy Management Type WM14 DI version Protection degree (front): IP40 2 digital outputs 16 freely configurable alarms with OR/AD logic linkable with up to 2 digital outputs RS422/485 serial output (MODBUS-RTU),

More information

RCMS460 and RCMS490 Series

RCMS460 and RCMS490 Series 4 T M RCMS460 and RCMS490 Series Digital Multi-Channel Ground Fault Monitor / Ground Fault Relay Grounded and High-Resistance Grounded AC/DC Systems Technical Bulletin NAE1042060 / 04.2013 BENDER Inc.

More information

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

Contents. Instruction Leaflet IL E Effective March HMi VU Series Instruction Leaflet. Description... Page. Preface...

Contents. Instruction Leaflet IL E Effective March HMi VU Series Instruction Leaflet. Description... Page. Preface... Instruction Leaflet IL04801003E Effective March 2013 HMi VU Series Instruction Leaflet Contents Description... Page Preface... 1 Safety Precautions... 1 Installation... 3 Wiring... 4 asic Inspection...

More information

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering METERSUK LTD s a l e s @ m e t e r s. c o. u k 0 1 5 2 4 5 5 5 9 2 9 Series Smart Energy Meter KEY FEATURES Single Phase Metering Single phase metering 4 din modules, Standard DIN rail Format (DIN43880)

More information

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL 1 Contents 1. Application... 5 2. meter set... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETy... 6 4. installation... 10 4.1. Mounting... 10 4.2. External

More information

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support PM-311x Quick Start Ver. 1.1 1. PM-311x introduction ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for single-phase

More information

Polaris 2000 User s Manual

Polaris 2000 User s Manual Polaris 2000 User s Manual DAE Instrument Corp. 2016/10/24 Version : 2.1us http://www.daeinstrument.com/ Page 2 Polaris 2000 User s Manual Polaris 2000 User s Manual, 2016, Oct. Copyright 2016 DAE Instrument

More information

DIRIS. The multi-function multi-measurement range MADE TO MEASURE

DIRIS. The multi-function multi-measurement range MADE TO MEASURE DIRIS A The multi-function multi-measurement range for managing YOUR ELECTRICAL NETWORKS MADE TO MEASURE DIRIS system: the reference Measurement is the key link in managing an energy efficiency project.

More information

CompoNet Gateway Unit for CC-Link

CompoNet Gateway Unit for CC-Link CompoNet Gateway Unit for CC-Link Overview of Gateway Unit...2 CompoNet Settings...2 CompoNet Gateway Unit for CC-Link...3 1 CRT1-series Smart Slave Units 1 Overview of Gateway Unit The CompoNet Gateway

More information