OFV-5000 Xtra Laser Vibrometer. Xtra sensitivity and versatility Datasheet. OFV-5000 Xtra Laser Vibrometer
|
|
- Angela Booker
- 5 years ago
- Views:
Transcription
1 OFV-5000 Xtra Laser Vibrometer The OFV-5000 Xtra Vibrometer Controller in combination with the new MLV-I-0 Sensor Head is designed to flexibly measure vibrational velocity, displacement and acceleration. The Xtra optical sensitivity gathers high-fidelity data from all surfaces even on dark, biological, rotating or moving sample objects. An alternative exchangeable fiber lens as an addon to the MLV-I-0 head enables a dual purpose use for small objects and facilitates overhead measurements. The compactness of this robust sensor with different lens options leads to a versatile use and an easy integration into test setups. This non-contact approach solves challenging applications like NDT, biomedical, long distance displacement measurements, quasi-static displacement measurement and shaker control. Highlights Non-contact vibration sensor with Xtra sensitivity High-fidelity data from all surfaces even on dark, biological or moving objects From µm-sized to large, distant objects High dynamic with wide bandwidth up to 4 MHz Remote operation keeps laser precisely focused OFV-5000 Xtra Laser Vibrometer Xtra sensitivity and versatility Datasheet
2 Technical data Models Version frequency velocity Best velocity resolution displacement Best displacement resolution Acceleration output Decoders M.5 MHz 5 m/s 0.04 µm s - / Hz O VX-09 R.5 MHz 5 m/s µm s - / Hz O VX-09, VX-08 V 4 MHz 5 m/s 0.04 µm s - / Hz ±88 nm 0. pm/ Hz VX-09, DX-300 MD.5 MHz 5 m/s 0.04 µm s - / Hz ±5 mm 0.75 pm/ Hz O VX-09, DX-900 O: Option; : Not available Best value of the typical resolution of the included decoders RD.5 MHz 5 m/s µm s - / Hz ±5 mm 0.75 pm/ Hz O VX-09, VX-08, DX-900 VD 4 MHz 5 m/s 0.04 µm s - / Hz ±5 mm 0. pm/ Hz VX-09, DX-900, DX-300 Metrological specifications Analog signal outputs BNC, ±0 V : Velocity signal Displacement signal AUX output 3 Digital signal output 4 velocity 4 S/PDIF, 4 bit, 48/96 ksa/s (available on request, only for VX-08 decoder) DC to 4 MHz ±5 m/s Depends on decoder configuration. 3 Displacement or acceleration signal, depends on decoder configuration (see table "Models"). 4 Notice: frequency, max. velocity and measurement depend on decoder configuration (see below). Filters Tracking filter Signal level PC interface High pass filter: 00 Hz, off Low pass filter: 5 khz, 0 khz, 00 khz, off 3 settings: slow, fast, off Bargraph on touchscreen and on sensor head Output as DC voltage signal (BNC, V) RS-3, remote control of the instrument settings Velocity decoders Decoder Description No. of s Typical resolution 5, 6 VX-08 Digital high-resolution velocity decoder velocity µm s - / Hz.5 m/s 0 Hz - 5 khz VX-09 Digital velocity decoder µm s - / Hz 5 m/s 0 Hz -.5 MHz Displacement decoders Decoder Description No. of s Resolution 5 displacement DX-300 DX-900 Analog displacement decoder for ultrasonic applications Broadband digital displacement decoder 0. pm/ Hz ±88 nm 30 khz - 4 MHz pm/ Hz ±5 mm 0 Hz -.5 MHz 5 Noise-limited resolution in the smallest measurement. The noise-limited resolution is defined as the signal amplitude (RMS) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, measured on a mirror. Acceleration decoder Decoder No. of s acceleration AX ,000 m/s 0.5 Hz - 0 khz 6 The attainable resolution is frequencydependent. The typical value refers to the center of the operating frequency.
3 General specifications Interface/display Dimensions OFV-5000 Xtra Controller 7" color touchscreen with interactive menu guidance 9" rack mounting, W x D x H: 450 x 360 x 50 mm (9", 84 HP/3U) without angle brackets MLV-I-0 Sensor Head Xtra W x H x L: 35 x 00 x 383 mm Weight 0 kg 4.55 kg Protection class IP0 IP40 Operating temperature Storage temperature Relative humidity Power supply Power consumption +5 C +40 C (4 F F) -0 C +65 C (4 F F) max. 80%, non-condensing VAC ±0%, 50/60 Hz max. 00 VA Optical specifications: MLV-I-0 Sensor Head Xtra Laser type Laser class Focus Maximum stand-off distance Measurement laser: invisible (IR), wavelength 550 nm, output power <0 mw Targeting laser: visible (green), wavelength nm, effective output power < mw Class, eye-safe, with both lasers in operation Auto focus, remote focus, manual focus Up to 00 m (with MLV-O-LRI long front lens, surface dependent) Working distance and laser spot size Front lenses MLV-O-SRI short MLV-O-LRI long Fiber heads for MLV-O-FMI-0 MLV-O-00 Mini Fiber Head MLV-O-0 Micro Spot Fiber Head Included with MLV- O-FMI-0 Fiber Lens (IR). Optional available for MLV-O-FMI-0 Fiber Lens (IR). Focal length [mm] Min. stand-off distance [mm] ± Exit beam diameter (/e ) [mm] Typical spot size in μm at 5 mm mm mm mm mm mm mm mm mm ,000 mm ,000 mm ,000 mm distance, Each additional meter add [μm] +83 3
4 Options and accessories Tripods VIB-A-T0 Standard Tripod Easy targeting on the object under test VIB-A-T05 Tripod with Geared Pan/Tilt Head For precise pointing of the sensor head. The geared pan/tilt head allows quick coarse adjustment and fine adjustment in 3 axes Optical accessories MLV-O-SRI SR Front Lens (IR) Short Range front lens for measuring at short working distances (highest depth of focus) MLV-O-LRI LR Front Lens (IR) Long Range front lens for measuring at long working distances MLV-O-FMI-0 Fiber Lens (IR) m Flexible measurements with m fiber cable on small objects or where space is restricted. Includes MLV-O-00 Mini Fiber Head and VIB-A-CAS08 Transportation Case MLV-O-00 Mini Fiber Head Small fiber head (0 mm diameter) with a laser spot size down to 8 µm for MLV-O-FMI-0 Fiber Lens (IR) m MLV-O-0 Micro Spot Fiber Head Small fiber head (4 mm diameter) with a laser spot size of 8 µm for MLV-O-FMI-0 Fiber Lens (IR) m 4
5 Positioning stages VIB-A-P35 Precision 4-Axes Stage XY-traverse stage featuring 8 mm travel with +/- 5 tip/tilt function for positioning a single 0 mm outer diameter Mini Fiber Head. OFV-036 Tip/Tilt Precision Stage For positioning a single 0 mm outer diameter Mini Fiber Head. Travel ±5. Transportation cases VIB-A-CAS07 Transportation Case for MLV-I-0 Sensor Head Xtra Robust transportation case for the sensor head (included with sensor head) VIB-A-CAS0 Transportation Case OFV-5xxx Robust transportation case for the OFV-5000 Xtra Controller Please contact Polytec s application and sales engineers who will help to choose the appropriate accessories like VibSoft data acquisition and analysis software. 5
6 Velocity decoders VX-09 digital velocity decoder Measurement Full scale output (peak) Typical resolution 3 acceleration linearity error mm/s/v m/s µm s - / Hz , , , ,00, ,400, ,000, , ,000, , ,000, Measurement s 50...,500 mm/s/v each feature an additional low pass with 50 khz frequency, higher resolution but reduced max. acceleration. The full scale values correspond to the maximum output voltage of 0 V peak. 3 The noise-limited resolution is defined as the signal amplitude (rms) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, for frequencies above khz measured on a mirror. The attainable resolution is frequency-dependent. The typical value refers to the center of the operating frequency. MHz g % V peak Range diagram Multi-purpose high frequency bandwidth digital decoder with high precision and high resolution True DC capability Well balanced properties regarding bandwidth, resolution and velocity limits make it the decoder of choice for most measurement applications Universal decoder, included in all models 00 m/s 5 m/s.5 m/s 0 m/s 5 m/s.5 m/s.5 m/s m/s 500 mm/s 50 mm/s 5 mm/s 00 mm/s 0 mm/s mm/s 00 µm/s 0 µm/s µm/s Lower Limit: 0 Hz.5 m/s/v.5 m/s/v 0.5 m/s/v 50 mm/s/v 5 mm/s/v 50 mm/s/v 5 mm/s/v.5 mm/s/v Ranges Detectable Acceleration: 4,000,000 g Vibrational :.5 MHz Min. Detectable Velocity: 0.04 µm/s 0. Hz Hz 0 Hz 00 Hz khz 0 khz 00 khz 50 khz MHz.5 MHz.5 MHz 0 MHz 6
7 VX-08 digital high-resolution velocity decoder Measurement Full scale output (peak) Typical resolution acceleration linearity error mm/s/v m/s µm s - / Hz , , , , The full scale values correspond to the maximum output voltage of 0 V peak. The noise-limited resolution is defined as the signal amplitude (rms) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, for frequencies above khz measured on a mirror. The attainable resolution is frequency-dependent. The typical value refers to the center of the operating frequency. khz g % Range diagram V peak Detectable Acceleration: 0,000 g 0 m/s.5 m/s m/s 500 mm/s 50 mm/s 5 mm/s 00 mm/s 50 mm/s 5 mm/s.5 mm/s 0 mm/s 5 mm/s mm/s 5 mm/s/v 50 mm/s/v 5 mm/s/v.5 mm/s/v 5 mm/s/v.5 mm/s/v.5 mm/s/v 0.5 mm/s/v Ranges Digital velocity decoder dedicated to low frequencies up to 5 khz with highest resolution Highest optical sensitivity for measurement on dark surfaces True DC capability Outstanding linearity and frequency response Included in models R and RD 00 µm/s 0 µm/s µm/s Lower Limit: 0 Hz Vibrational : 5 khz Min. Detectable Velocity: µm/s 0. Hz Hz 0 Hz 00 Hz khz 5 khz 0 khz 0 khz 5 khz 00 khz MHz 7
8 Displacement decoders DX-900 broadband digital displacement decoder Measurement Full scale output (peak-to-peak) Resolution 3 velocity µm/v µm nm khz m/s , , , , , , , , , , , , , , , ,500 5,50 5, ,500 5,500 50, , ,000 00, ,500 5,500 50, ,500 5 The full scale values correspond to ±0 V (peak-to-peak) maximum output voltage. The resolution corresponds to the quantization step of approx. 0.3 mv at the analog output. Noise-limited resolution: < 0.75 pm/ Hz in the smallest measurement. The noise-limited resolution is defined as the signal amplitude (rms) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, for frequenciey above khz measured on a mirror. 3 When a suitable measurement has been selected for the digital velocity decoder VX-09, which is required for using the DX-900. Range diagram Amplitude (peak) Broadband displacement decoder up to.5 MHz Supplements VX-09 velocity decoder for high precision displacement measurements with resolutions down to 40 pm 6 measurement s Included in models MD, RD and VD 5 mm 00 mm 50 mm 5 mm.5 mm 0 mm 5 mm.5 mm.5 mm mm 500 µm 50 µm 5 µm 00 µm 50 µm 5 µm.5 µm 0 µm 5 µm.5 µm.5 µm µm 00 nm 0 nm Displacement: 5 mm Lower Limit: 0 Hz.5 m/s/v.5 m/s/v 0.5 m/s/v 5 mm/s/v 50 mm/s/v 5 mm/s/v.5 mm/s/v 50 mm/s/v :.5 MHz Hz 0 Hz 00 Hz khz 0 khz 00 khz 50 khz MHz.5 MHz.5 MHz 0 MHz 8
9 DX-300 analog displacement decoder for ultrasonic applications Measurement nm/v Full scale output (peak) nm Resolution pm/ Hz 5 ±88 < ,000 ( 3dB) The full scale value corresponds to the output voltage swing of ±.5 V at load resistance 50 Ω. The noise-limited resolution is defined as the signal amplitude (rms) at which the signal-to-noise ratio is 0 db with Hz spectral resolution for frequencies above 30 khz measured on a mirror. khz Range diagram Amplitude (peak-peak) µm 375 nm 00 nm Displacement: 375 nm Displacement decoder for measuring smallest motions up to ± 88 nm with a large frequency bandwidth from 30 khz up to 4 MHz 0 nm nm For measurements on ultrasonic transducers, detection of ultrasonic pulses and to observe fast transient motions of MEMS devices 00 pm 0 pm pm < 0. pm khz 0 khz Lower Limit: 30 khz 30 khz 00 khz MHz 0 MHz 4 MHz : 4 MHz 00 MHz Special high-pass filter suppresses low frequency (acoustic) vibrations and allows the detection of smallest high-frequency vibrations even under noisy ambient conditions Additional MHz low-pass filter improves resolution performance in lower frequency Included in models V and VD 9
10 Acceleration decoder AX-00 acceleration decoder Measurement Measurement velocity accelaration Full scale accelaration output (peak) Signal frequency (switchable) mm/s/v m/s²/v m/s² Hz.5 5, ,000 / 0, , ,000 / 0, , ,000 / 0,000 5,50, ,000 / 0,000 50,500 5, ,000 / 0, ,000 50, ,000 / 0,000,50,500 5, ,000 / 0,000,500 5,000 50, ,000 / 0,000 The full scale values correspond to the maximum output voltage of 0 V peak. Value is valid, as long as the corresponding velocity measurement is not saturated. Acceleration Range diagram m/s 0.5Hz 0kHz bandwidth 50,000 m/s² maximum acceleration 8 measurement s (coupled to VX-09 velocity decoder s) Available as an option in models M, MD, R and RD m/s 5000 m/s m/s m/s 5000 m/s 500 m/s 0000 m/s 5000 m/s 500 m/s 50 m/s 000 m/s 00 m/s 0 m/s Velocity 5 m/s Velocity.5 m/s Velocity 5 m/s Velocity.5 m/s Velocity.5 m/s Velocity 500 mm/s Velocity 50 mm/s Velocity 5 mm/s m/s 00 mm/s 0 mm/s 5 mm/s mm/s 0. Hz 0.5 Hz Min. Limit: 0.5 Hz Hz 0 Hz 00 Hz khz.6 khz 0 khz : 0 khz 0 khz 00 khz 0
11 Compliance with standards Laser safety IEC Electrical safety IEC 600- EMC IEC 636- Emission: Limit class B IEC/EN and Immunity: IEC/EN to and IEC/EN Dimensions 3.8 A Ø M6 6 Ø4F8 5 /4-0 UNC Ø 4F M6 6 B B 00 Manufactured by: GmbH D Waldbronn, Germany Model No.: MLV Serial No.: x xx xxxx Mfg.-Date: mm.yyyy 53 All dimensions in mm if not marked otherwise A Stand-off distance B Beam
12 Measuring vibration non-contact and highly precise with Polytec laser Doppler vibrometers. The optional VibSoft data acquisition hardware and analysis software allows quick and intuitive analysis and visualization of your vibration measurement data. OM_DS_OFV-5000_Xtra_E_ /05 - Technical specifications are subject to change without notice. Polytec GmbH (Germany) Polytec-Platz Waldbronn Tel info@polytec.de Polytec GmbH (Germany) Vertriebs- und Beratungsbüro Schwarzschildstraße 489 Berlin Tel Polytec, Inc. (USA) North American Headquarters 6400 Bake Parkway Suites 50 & 00 Irvine, CA 968 Tel info@polytec.com Central Office 046 Baker Road Dexter, MI 4830 Tel East Coast Office Cabot Road Suites 0 & 0 Hudson, MA 0749 Tel Polytec Ltd. (Great Britain) Lambda House Batford Mill Harpenden, Herts AL5 5BZ Tel info@polytec-ltd.co.uk Polytec France S.A.S. Technosud II Bâtiment A 99, Rue Pierre Semard 930 Châtillon Tel info@polytec.fr Polytec Japan Arena Tower, 3th floor 3--9, Shinyokohama Kohoku-ku, Yokohama-shi Kanagawa Tel info@polytec.co.jp Polytec South-East Asia Pte. Ltd. Blk 400 Ang Mo Kio Ave 0 #06-06 TechPlace I Singapore Tel info@polytec-sea.com Polytec China Ltd. Room 40, Tower B Minmetals Plaza No. 5 Chaoyang North Ave Dongcheng District 0000 Beijing Tel info-cn@polytec.com
Aircraft Health Monitoring. Aircraft Health Monitoring Laser Vibrometry for Damage Detection Using Lamb Waves Application Note
Aircraft Health Monitoring Aircraft Health Monitoring Laser Vibrometry for Damage Detection Using Lamb Waves Application Note 2 Lamb Wave Inspection Uses Guided Ultrasonic Waves to Detect Damage in Structures.
More informationLaser-Based Evaluation of Cement Hydration. Laser-Based Evaluation of Cement Hydration Non-Contact Inspection of Curing Processes Application Note
Laser-Based Evaluation of Cement Hydration Laser-Based Evaluation of Cement Hydration Non-Contact Inspection of Curing Processes Application Note This Application Note Shows How to Inspect Cement-Based
More informationVDD PC-Based Digital Vibrometer
Data sheet VDD PC-Based Digital Vibrometer Modular Vibrometer System OFV-5000 Vibrometer Controller OFV-505/503 Standard Sensor Heads OFV-534 Compact Sensor Head OVF-551/552 Fiber Interferometers VDD PC-Based
More informationHSV-2000 High Speed Vibrometer
HSV-2000 High Speed Vibrometer Measurement of Vibration Velocity and Displacement at High Speeds Non-contact Single point or differential Velocities up to ± 30 m/s High Speed Capability The HSV-2000 High
More informationLSV Laser Surface Velocimeter. LSV Laser Surface Velocimeter Non-contact speed and length measurement Product brochure
LSV Laser Surface Velocimeter LSV Laser Surface Velocimeter Non-contact speed and length measurement Product brochure Your measurement task our solution Yield, quality, throughput Keep your process under
More informationHSV-2000 High Speed Vibrometer
HSV-2000 High Speed Vibrometer Measurement of Vibration Velocity and Displacement at High Speeds Non-contact Single point or differential Velocities up to ± 30 m/s High Speed Capability The HSV-2000 High
More informationVibroFlex Connect Configurable core of the modular vibration sensing system Preliminary datasheet. VibroFlex Connect
VibroFlex Connect The Polytec VibroFlex laser Doppler vibrometer is a modular high-performance solution for non-contact vibration measurement. It offers unrivalled measurement performance and versatility
More informationSurface Vibration Measurement on Rotating Components
Application Note Surface Vibration Measurement on Rotating Components Polytec Application Notes A Aerospace B Audio & Acoustics C Automotive D Data Storage G General Vibrometry M Microstructures & -systems
More informationVibSoft Data Acquisition Software
Data sheet VibSoft Data Acquisition Software Modular Vibrometer System OFV-5000 Vibrometer Controller OFV-505/503 Standard Sensor Heads OFV-534 Compact Sensor Head OVF-55/552 Fiber Interferometers PC-Based
More informationVibSoft Data Acquisition Software
Data sheet VibSoft Data Acquisition Software Modular Vibrometer System OFV-5000 Vibrometer Controller OFV-505/503 Standard Sensor Heads OFV-534 Compact Sensor Head OVF-55/552 Fiber Interferometers PC-Based
More informationLight Years Our Story, Chapter by Chapter
Polytec GmbH Polytec-Platz 1-7 76337 Waldbronn Tel. +49 7243 604-0 info@polytec.de Polytec GmbH Vertriebs- und Beratungsbüro Berlin Schwarzschildstraße 1 12489 Berlin Tel. +49 30 6392-5140 Polytec France
More informationVDD PC-Based Digital Vibrometer
VDD PC-Based Digital Vibrometer MODULAR VIBROMETER SYSTEM OFV-5000 Vibrometer Controller OFV-505/503 Standard Sensor Heads OFV-534 Compact Sensor Head OVF-551/552 Fiber Interferometers VDD PC-Based Digital
More informationVibSoft Data Acquisition Software
Data sheet VibSoft Data Acquisition Software Modular Vibrometer System OFV-5000 Vibrometer Controller OFV-505/503 Standard Sensor Heads OFV-534 Compact Sensor Head OVF-55/552 Fiber Interferometers PC-Based
More informationFiber Optic Cables for the TopSens Series
Fiber Optic Cables for the TopSens Series E2000 Push-Pull Connector Polytec GmbH (Germany) Polytec-Platz 1-7 76337 Waldbronn Tel. + 49 7243 604-0 Fax + 49 7243 69944 info@polytec.de Standard E2000 connector
More information3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn
3D Optical Motion Analysis of Micro Systems Heinrich Steger, Polytec GmbH, Waldbronn SEMICON Europe 2012 Outline Needs and Challenges of measuring Micro Structure and MEMS Tools and Applications for optical
More informationLaser Surface Velocimeter. LSV Series 6000
Laser Surface Velocimeter LSV Series 6000 Built Mill Tough 2 Increase Yield and Throughput Decrease Downtime Polytec s Industrial Laser Surface Velocimeter (LSV) is specifically designed to measure the
More informationMicroscopic Laser Doppler Vibrometer
Microscopic Laser Doppler Vibrometer System Configuration - 1 PC Controller (APU-Analog processing unit, DPU-Digital processing unit) Optic Head (MEMS Type, XS Type) Function Generator Power Supply Testing
More informationISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits
ISOBE5600 Isolated Probe Systems - ISOBE5600 Isolation system - ISOBE5600 Transient recorder Data sheet Features and Benefits ISOBE5600 Isolation system - Cost-effective - Fiber-optic isolation - Analogue-in
More informationSapphire FP. Fiber Pigtailed Lasers from Deep Blue to Orange FEATURES
Sapphire FP Fiber Pigtailed Lasers from Deep Blue to Orange Sapphire FP is a series of true fiber-pigtailed lasers based on Coherent s unique OPSL (Optically Pumped Semiconductor Laser) technology. OPSL
More information7600 Isolated Digitizer and Receiver
7600 Isolated Digitizer and Receiver Data sheet GEN series Features and Benefits - Complete single-channel isolated analog input subsystem - Rugged enclosure for use in EMI hostile environments - Shock
More informationPhotoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series
Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series All three beam types provide ample long-distance detection of 1,000 mm for Diffuse Reflective Models.
More informationModule 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry
The Lecture Contains: Laser Doppler Vibrometry Basics of Laser Doppler Vibrometry Components of the LDV system Working with the LDV system file:///d /neha%20backup%20courses%2019-09-2011/structural_health/lecture36/36_1.html
More informationM70LL Laser Distance Sensor
M7LL Laser Distance Sensor for automated manufacturing with Ethernet interface to connect with PLC The analog sensors of series M7LL use a PSD for their receiver optics. This assures a position measurement
More informationFLIR K2. FLIR-DIRECT.ca
Copyright All rights reserved worldwide. Names and marks appearing herein are either registered trademarks or trademarks of FLIR Systems and/or its subsidiaries. All other trademarks, trade names or company
More informationMLV12 Series Dura-Vue TM Sensors
MLV Series Dura-Vue TM Sensors Diffuse Mode with Background Evaluation See page 5 Reliable detection of all surfaces regardless of color or shape Cross-talk immunity Sensing Range: 5 mm Output: -in- Retro-Reflective
More informationMLV40 Series Miniature Sensors
MLV4 Series Miniature Sensors Diffuse Mode See page 54 Features: Adjustable sensitivity Complementary outputs Sensing Range: 5 mm Outputs: NPN, PNP Thru-Beam Mode See page 57 Rugged metal housing Compact
More informationRadiated Immunity Test System 6 GHz
The consist of an integrated RF signal generator, RF switch and interfaces. The unit is designed for various radiated EMC applications in the 80 MHz to 6 GHz frequency range. In addition to the generator,
More informationDistance Sensors BOD 26K.... with optional Master-Slave-Mode
Distance... with optional Master-Slave-Mode Laser Distance The Balluff distance sensor not only detects the presence of objects, but can also indicate their precise position or location. This means the
More informationRADIATED IMMUNITY TEST SYSTEM 6 GHz
Integrated signal generator 80 MHz to 6 GHz Integrated RF switch network Integrated freely configurable pulse modulators ( µs to 00 s) for radar pulse profiles Multiple options.5 TFT color display Safety
More informationAT500 AT0023 AT7500. Detects microvibration without contact. Sensor unit incorporated in the laser tube and demodulator
Detects microvibration without contact Sensor unit incorporated in the laser tube AT0023 Sensor unit incorporated in the laser tube and demodulator AT500 Scanning-Type Laser Doppler Vibrometer System AT7500
More information430. The Research System for Vibration Analysis in Domestic Installation Pipes
430. The Research System for Vibration Analysis in Domestic Installation Pipes R. Ramanauskas, D. Gailius, V. Augutis Kaunas University of Technology, Studentu str. 50, LT-51424, Kaunas, Lithuania e-mail:
More informationCOMPACT Diode Laser System (Water-Cooled)
COMPACT Diode Laser System (Water-Cooled) Easy-to-integrate CW system consists of a compact 19 (11HU including water-air-chiller), rack-mountable chassis and metal-armored fiber. Can be combined with DILAS
More informationMetis H311 / H322. Highly Advanced, Full Featured 2-Color High-Speed Pyrometers
Metis H311 / H322 Highly Advanced, Full Featured 2-Color High-Speed Pyrometers High-Speed 2-color pyrometer for non-contact temperature measurement in short wavelength spectral range, primarily for measurements
More informationCWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W
CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W FOR TESTS ACCORDING TO... > EN 300329 > EN 300340 > EN 300342-1 > EN 300386 V1.3.2 > EN 301489-1 > EN 301489-17 > EN 301489-24 > EN 301489-7 > EN 55024 > EN 61000-4-6
More informationLaser Displacement Sensor 3Z4M
Laser Sensor High Resolution to 1 µ or 5 µ, Gives Precise Linear Output and Displays Distance Distance is displayed in millimeters on controller Ready-to-use linearized output is both -1 to +1 VDC and
More informationGreen Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500 US EDITION
Green Scan Laser PhotocoagulatorGYC-500 Vixi Green Laser PhotocoagulatorGYC-500 US EDITION The Small, Incredibly Versatile Green Laser Photocoagulator The GYC-500 Vixi / GYC-500 is a solid state green
More informationNSG Hard keys for important functions. 5.7 color display, easy to use firmware. 3 power meter
The, successor of the NSG 070, is a multifunctional EMC immunity test system. Its large frequency range from to G and its modular set-up using internal or external amplifiers enable a large variety of
More informationI-SERIES. Excellent Cost-Performance High-Accuracy Measurement. CMOS Analog Laser Sensor. Intelligent Sensor. IA Series
NEW CMOS Analog Laser Sensor IA Series Excellent Cost-Performance High-Accuracy Measurement KEYENCE BRINGS YOU A GENERAL-PURPOSE ANALOG LASER SENSOR Intelligent Sensor I-SERIES NEW CMOS Analog Laser Sensor
More informationT22. Torque transducer. Special features. Data sheet
T22 Torque transducer Special features - Nominal (rated) torques 0.5 Nm, 1 Nm, 2 Nm, 5 Nm, Nm, Nm, 50 Nm, 0 Nm, 0 Nm, 500 Nm and 1 knm - Nominal (rated) rotational speed up to 000 rpm (depending on measuring
More informationMetis M311 / M Color Pyrometer Series
Metis M311 / M322 2-Color Pyrometer Series Self contained 2-color pyrometer for non-contact temperature measurement in short wavelength spectral range, primarily for measurements on metals and bright and
More informationVISOR object sensor In a class of its own.
VISOR object sensor In a class of its own. 1.3 Mpx Vision sensors and systems Optical sensors Ultrasonic sensors Inductive sensors Capacitive sensors It s set up! VISOR. The vision sensor with which you
More informationCWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W
CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W FOR TESTS ACCORDING TO... > BMW GS 95002 (2010) > DaimlerChrysler DC-10614 > DaimlerChrysler DC-11224 > EN 300329 > EN 300340 > EN 300342-1 > EN 300386 V1.3.2
More informationTesT system for ConduCTed and radiated immunity
nsg 070 TesT system for ConduCTed and radiated immunity The, successor of the NSG 070, is a multifunctional EMC immunity test system. Its large frequency range from to G and its modular set-up using internal
More informationIntegrated Diode Laser System DioPower
Integrated Diode Laser System DioPower PC with LETSoft program DioPower Integrated Components Applications Laser Diode from 15 to 120W Material processing Laser Diode driver up to 6V / 100A Laser soldering
More informationSapphire LP. CW Visible Lasers from Deep Blue to Orange. Superior Reliability & Performance. Sapphire LP Features:
Sapphire LP Features: Sapphire LP is a series of compact CW visible lasers based on Coherent s unique OPSL (Optically Pumped Semiconductor Laser) technology. OPSL technology not only provides established
More informationSENSORS S62 SERIES. Telephone: Visit Our Website: us: DISTRIBUTED & SUPPORTED by:
photoelectric compact sensors S6 SERIES S6 photoelectric sensor line offers compact dimensions and competitive prices for all basic and advanced models. All universal optic functions are available at best
More informationVibration amplifier Model 6634C
Key features Programmable full scale and sensitivity Acceleration, velocity and displacement outputs Setups stored in non-volatile memory Peak hold Optional RS-232 computer interface Optional 6 pole programmable
More informationPOLARIZATION EXTINCTION RATIO MEASUREMENT TEST SETFOR V-GROOVE ASSEMBLIES AND PM PATCHCORDS
219 Westbrook Rd, Ottawa, ON, Canada, K0A 1L0 Toll Free: 1-800-361-5415 Tel:(613) 831-0981 Fax:(613) 836-5089 E-mail: sales@ozoptics.com POLARIZATION EXTINCTION RATIO MEASUREMENT TEST SETFOR V-GROOVE ASSEMBLIES
More informationCharge Meter. Electronics & Software. Universally Applicable for Piezoelectric Measuring Technology. Type 5015A...
Electronics & Software Charge Meter Type 5015A... Universally Applicable for Piezoelectric Measuring Technology This instrument can be used wherever mechanical quantities are measured with piezoelectric
More informationLaser Speckle Reducer LSR-3000 Series
Laser Speckle Reducer LSR-3000 Series Speckle noise from a laser-based system is reduced by dynamically diffusing the laser beam. A diffuser is bonded to a thin elastic membrane, which includes four independent
More informationTutorial: 3D Scanning Vibrometry for. IMAC XXVII D. E. Oliver, Polytec, Inc.
Tutorial: 3D Scanning Vibrometry for Structural Dynamics Measurements IMAC XXVII D. E. Oliver, Polytec, Inc. Content Principles of Laser Doppler Vibrometry Scanning Laser Doppler Vibrometry (SLDV) Limitations
More informationPICO MASTER 200. UV direct laser writer for maskless lithography
PICO MASTER 200 UV direct laser writer for maskless lithography 4PICO B.V. Jan Tinbergenstraat 4b 5491 DC Sint-Oedenrode The Netherlands Tel: +31 413 490708 WWW.4PICO.NL 1. Introduction The PicoMaster
More informationTemposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet
Temposonics Magnetostrictive Linear Position Sensors ER Analog Compact sensor model Operating temperature up to +75 C (+167 F) Ideal for flexible mounting MEASURING TECHNOLOGY The absolute, linear position
More informationMetis M311 / M322. Highly Advanced, Full Featured 2-Color Pyrometer Series
Metis M311 / M322 Highly Advanced, Full Featured 2-Color Pyrometer Series Self contained 2-color pyrometer for non-contact temperature measurement in short wavelength spectral range, primarily for measurements
More informationCWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W
CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W FOR TESTS ACCORDING TO... > EN 300329 > EN 300340 > EN 300342-1 > EN 300386 V1.3.2 > EN 301489-1 > EN 301489-17 > EN 301489-24 > EN 301489-7 > EN 55024 > EN 61000-4-6
More informationOBIS CellX. The Universal Light Engine FEATURES
OBIS CellX The Universal Light Engine OBIS CellX is a multi-wavelength platform for use as the laser excitation Light Engine in applications requiring or laser wavelengths from a single module. CellX delivers
More information200 MHz Variable Gain Photoreceiver
The image shows model -FST with 1.035-40 threaded flange and coupler ring. Features Applications Adjustable transimpedance gain from 10 2 to 10 8 V/A Wide bandwidth up to 200 MHz Si-PIN photodiode covering
More informationSENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission
Compact Sensors - S6 S6 The most complete universal sensor in a compact x housing Sensors with red, infrared or LASER emission from 3 cm to m Polarized retroreflective up to 0 m Multivoltage 4-40Vac/4-60Vdc
More informationArbitrary/Function Generator AFG1000 Series Datasheet
Arbitrary/Function Generator AFG1000 Series Datasheet 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Compatible with TekSmartLab
More informationThe series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the
Programmable AC Power Source MODEL 61500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 61500 SERIES Chroma AC power source 61500 series sets waveform as well as measurements such as up the new
More informationStepping Motor Station
Stepping Motor Station PV-7300 System A single system can measure all seven of the characteristics important in a stepping motor, namely the -T characteristic, holding torque, detent torque, pull-in torque,
More informationimproved stability (compared with
Picosecond Tunable Systems Nanosecond Lasers NT230 SERIES NT230 series lasers deliver high up to 10 mj energy pulses at 100 Hz pulse repetition rate, tunable over a broad spectral range. Integrated into
More informationCompact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
More informationCompact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
More informationMore Precision. capancdt DTV // Measuring Disc Thickness Variation
More Precision capancdt DTV // Measuring Disc Thickness Variation Measuring Disc Thickness Variation capancdt DTV Non-contact measurement of Disc Thickness Variation Dynamic and precise measurements Robust
More informationUniversally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Instant value. Extreme values ors statistic measurements
Electronics & Software Charge Meter Universally Applicable for Piezoelectric Measuring Technology Type 5015A... This instrument can be used wherever mechanical quantities are measured with piezoelectric
More informationDATA SHEET. OD Precision. Displacement sensors for precise and comprehensive measurement tasks
DATA SHEET OD Precision Displacement sensors for precise and comprehensive measurement tasks OD Precision Displacement sensors for precise and comprehensive measurement tasks Displacement sensors from
More informationDigital Fiber-Optic Switches
CP-PC-2259E Digital Fiber-Optic Switches Model HPX-EG0 0/01 : Standard Model HPX-EG/ 51 : Long-dis tance Sensing Satisfaction Freedom from Frequent Adjustments Please read Terms and Conditions from the
More informationUniversally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Extreme values ors statistic measurements
Electronics & Software Charge Meter Type 5015A... Universally Applicable for Piezoelectric Measuring Technology This instrument can be used wherever mechanical quantities are measured with piezoelectric
More informationZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View
Product Information Version 1.0 ZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View ZEISS Axiocam 503 color Sensor Model
More information648. Measurement of trajectories of piezoelectric actuators with laser Doppler vibrometer
648. Measurement of trajectories of piezoelectric actuators with laser Doppler vibrometer V. Grigaliūnas, G. Balčiūnas, A.Vilkauskas Kaunas University of Technology, Kaunas, Lithuania E-mail: valdas.grigaliunas@ktu.lt
More informationTemposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet
Temposonics Magnetostrictive Linear Position Sensors ER SSI Compact sensor model Operating temperature up to +75 C (+167 F) Ideal for flexible mounting MEASURING TECHNOLOGY The absolute, linear position
More informationTIGER Femtosecond and Picosecond Ti:Sapphire Lasers. Customized systems with SESAM technology*
TIGER Femtosecond and Picosecond Ti:Sapphire Lasers Customized systems with SESAM technology* www.lumentum.com Data Sheet The TIGER femtosecond and picosecond lasers combine soliton mode-locking, a balance
More informationAngle Encoder Modules
Angle Encoder Modules May 2015 Angle encoder modules Angle encoder modules from HEIDENHAIN are combinations of angle encoders and high-precision bearings that are optimally adjusted to each other. They
More informationFARTHER THAN YOU CAN SEE OPTICAL DISTANCE MEASUREMENT WITH VDM100 FACTORY AUTOMATION
FARTHER THAN YOU CAN SEE OPTICAL DISTANCE MEASUREMENT WITH VDM100 FACTORY AUTOMATION VDM100 DISTANCE MEASUREMENT UP TO 300 METERS Farther than you can see Indeed! The new VDM100 works perfectly in distances
More informationAgilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet
Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Data Sheet DC CHARACTERISTICS [1] ACCURACY ± (% of reading + % of range) Temperature Cefficient
More informationRadiated immunity test system 6 GHz
its 6006 The consist of an integrated RF signal generator, RF switch and interfaces. The unit is designed for various radiated EMC applications in the 80 MHz to 6 GHz frequency range. In addition to the
More informationCWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ
CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC 61000-4-16, IEC 61000-4-19 ANNEX C, 0HZ (DC) TO 165KHZ FOR TESTS ACCORDING TO... > EN 61000-4-16 > IEC 60255-22-7 > IEC 60255-26
More informationVery High Frequency Calibration of Laser Vibrometer up to 350 khz
Very High Frequency Calibration of Laser Vibrometer up to 350 khz Requirements, Solutions and Traceability Dr. Martin Brucke, Frank Schulz There is simply no substitute for knowing what you re doing Jeff
More informationCoherent Laser Measurement and Control Beam Diagnostics
Coherent Laser Measurement and Control M 2 Propagation Analyzer Measurement and display of CW laser divergence, M 2 (or k) and astigmatism sizes 0.2 mm to 25 mm Wavelengths from 220 nm to 15 µm Determination
More informationZ500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System
Profile Measuring System High-Precision Sensor that Measures and Displays an Object's Profile. Features OMRON's original line beam method provides a complete solution to profile measurement problems. Conventional
More informationCUBE. Diode Laser System FEATURES
CUBE Diode Laser System The Coherent CUBE laser is a compact all-in-one laser system. CUBE lasers offer wavelengths from 75 nm to 70 nm with output power as high as 00 mw. Based on laser diode technologies
More informationKistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...
Electronics & Software Kistler LabAmp Charge Amplifier and Data Acquisition Unit for Dynamic Measurements This universal laboratory charge amplifier can be used wherever dynamic signals 1) of mechanical
More informationGFT Channel Digital Delay Generator
Features 20 independent delay Channels 100 ps resolution 25 ps rms jitter 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every channel Four triggers Three are repetitive from three
More informationTemposonics. Magnetostrictive Linear Position Sensors. EP / EL Start / Stop Data Sheet
Temposonics Magnetostrictive Linear Position Sensors EP / EL Start / Stop For standard applications Position measurement with more than one magnet Ideal for limited installation space MEASURING TECHNOLOGY
More informationTemposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet
Temposonics Magnetostrictive Linear Position Sensors EP2 Analog Optimal price- / performance ratio Position measurement with more than one magnet Smooth & compact Temposonics EP2 Analog MEASURING TECHNOLOGY
More informationContrast Sensors. SICK The pioneer in contrast sensors for more than 60 years
P r o d u c t i n f o r m at i o n Contrast Sensors SICK The pioneer in contrast sensors for more than 60 years Top products Contrast sensors They put registration marks into a proper light SICK contrast
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationTechnical Explanation for Displacement Sensors and Measurement Sensors
Technical Explanation for Sensors and Measurement Sensors CSM_e_LineWidth_TG_E_2_1 Introduction What Is a Sensor? A Sensor is a device that measures the distance between the sensor and an object by detecting
More informationTemposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet
Temposonics Magnetostrictive Linear Position Sensors EP / EL Analog For standard applications Position measurement with more than one magnet Ideal for limited installation space MEASURING TECHNOLOGY The
More informationSCANNING LASER VIBROMETRY FOR DETECTION NOISE SOURCES WITH HIGH SPATIAL RESOLUTION
SCANNING LASER VIBROMETRY FOR DETECTION NOISE SOURCES WITH HIGH SPATIAL RESOLUTION Dipl.-Ing (FH) Sven Frank, Dr. Jochen Schell, Dr. Reinhard Behrendt Polytec GmbH, Polytec-Platz 1-7, D-76337 Waldbronn,
More informationPRODUCT DATA. 16-channel DeltaTron Conditioning Amplifiers Types 2694-A/B/C/D. Features and Uses
PRODUCT DATA 16-channel DeltaTron Conditioning Amplifiers s -A/B/C/D The family of 16-channel DeltaTron conditioning amplifiers comprises of general signal- conditioning amplifiers for voltage and DeltaTron
More informationPortable Multi-Channel Recorder Model DAS240-BAT
Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes
More informationAdvanced Tachometer FT A digital tachometer that doesn't require. rotational pulse signals. FFT calculations performed by the device enable
Advanced Tachometer A digital tachometer that doesn't require rotational pulse signals FFT calculations performed by the device enable measurement of rotational speed by sensing fluctuations in rotation-synchronized
More informationRota-Sonde DC4500. Smart display with Signal level. Easy alignment with Laser Line. Design for the most difficult applications
Scanning HOT METAL DETECTOR Rota-Sonde DC4500 Smart display with Signal level Easy alignment with Laser Line Design for the most difficult applications Very High Sensitivity 360 F Lt 1445 1 Applications
More informationExample: ZX-BGS-DS300P-2M ZX Series - Diffuse Background Suppression Type - Distance Settable, 300mm Sensing Distance, PNP - 2m Cable
Laser Spot Sensor Background Suppression Type SALIENT FEATURES Ø1mm Spot size 250 µ sec Response External Laser Control Back Ground Suppression IP-67, Shock Resistant - 50G Measurement Class II LASER Product
More informationV8 Vibration Test Systems
V8 V8 Vibration Test Systems V8-440 Shaker system: configuration and performance parameters V8-440 Metric American Armature diameter 440 mm 17.3 in Sine force peak (stabilised) 57,827 N 13,000 lbf Sine
More informationDATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM
DATA SHEET 34450A Multimeter 5.5 Digit Dual Display, Benchtop DMM Features Fast reading speed of up to 190 readings/sec 0.015% DCV accuracy Multiple connectivity options USB 2.0, Serial Interface (RS-232)
More informationINTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection
Shantou Institute of Ultrasonic Instruments Co., Ltd. Add: 77 Jinsha Road, Shantou, Guangdong 515041, China Tel: 86-754-88250150 Fax: 86-754-88251499 Http://www.siui.com/ndt Product Data CTS-9009 Digital
More information[ tima-datasheet-en v11.1 ]
specifically designed for protection, automation and control applications in power systems 60 ns (99%) maximum time deviation single or dual 10/100Base-T Ethernet port(s) VLAN / IEEE 802.1Q support RS232
More information