Conductivity. Handheld conductivity meters
|
|
- Abel Buddy Bailey
- 5 years ago
- Views:
Transcription
1 Electrical Meters Meters Handheld conductivity meters cells Portable conductivity meters Accessories conductivity meters The conductivity is a cumulative parameter for the ionic concentration of a solution. The more salt, acid or alkali in a solution, the greater its conductivity. The unit of conductivity is S/cm. The scale for aqueous solutions begins with pure water at a conductivity of 0.05 µs/cm (25 C). Naturally occurring waters such as drinking water or surface water have a conductivity in the range µs/cm. The upper end of the scale is reached by some bases such as potassium hydroxide solutions with a conductivity of just over 1000 ms/cm. In practice conductivity measurements are used for applications such as monitoring plants in which ultrapure water is produced and determining the salinity of sea water. of aqueous solutions µs/cm ms/cm 0, Feedwater for high-pressure boilers Fully deionized water (ion exchanger) Deionized water Drinking water Wastewater Surface water Brackish water, sea water Industrial process water Concentrated acids and bases is measured by making a measurement of the electrical resistance. The simplest kind of measuring cell used consists of two similar electrodes. An alternating voltage applied to one of the electrodes causes the ions in the solution to migrate towards the electrodes. The more ions in the solution, the greater the current which flows between the electrodes. The instrument measures the current and uses Ohm's law to calculate first the conductance of the solution and then - by taken the cell data into account - the conductivity. Literature 76 Further information on this subject can be requested from WTW: Application reports Offprints
2 Meters & Field General Handheld conductivity meters Portable conductivity meters meters for every application Model from page Handheld Quality in a set of three 78 conductivity meters - Simple to use - Proven with memory function - All-rounder with interface Portable Classic 82 conductivity meters robust, shockproof, waterproof, portable, conductivity measurement at depths down to 100 m inolab top quality in 3 stages 84 conductivity meters - Simple and reliable - Compact and communicative - Flexible and powerful cells 88 Standard cells 89 Special cells 89 meter accessories Flow-thru cells 94 Stands and cell holders 94 Calibration and testing agents 95 For documentation Software, printer and accessories 180 ISE ORP ph Oxygen (D.O.) Respiration BOD Multi- Parameter Sample Preparation Colony Counter Further instruments for conductivity measurement from page Multi-parameter instruments 96 Photometry Turbidity Software, Printers conductivity meters Customer Service 77
3 General Information about handheld conductivity meters can be found on pages Meters Handheld Meters Cond 315i, Cond 330i and Cond 340i NEW Handy Dust- and waterproof Easy to use GLP-conform Low-power system allows continuous operation for up to 2500 h Long usability Complete in SET Pocket-size precision Universal conductivity meters with large multifunction display for measurement of conductivity, temperature, salinity and total dissolved solids. With the proven dirt-insensitive Tetracon 4-electrode system they offer the highest degree of precision and operating comfort. 78
4 Cond 315i, Cond 330i, Cond 340i handy waterproof GLP-conform Handheld Meters & Field ISE ORP ph General Cond 315i: The simple conductivity meter for meeting higher demands. With only 5 keys for error-free measurement with parallel temperature measurement, automatic temperature compensation, 4-electrode measuring technology Oxygen (D.O.) Cond 330i: Robust and waterproof handheld conductivity meter for battery operation; with parallel temperature display, integrated datalogger, GLP supporting functions, automatic and manual temperature compensation with linear temperature function and non-linear function for ultrapure water and natural waters according to DIN and EN The temperature compensation can be switched off; either 20 C or 25 C can be selected as the reference temperature Cond 340i: As Cond 330i, but with additional analog and digital RS 232 output and optional mains power supply Respiration BOD Multi- Parameter Sample Preparation Software, Printers Colony Counter Turbidity Photometry Cond 315i IP 66 IP 67 Customer Service Year 3 Warranty 79
5 SET Equipment Each handheld conductivity meter is available in a complete equipment set SET equipment for Cond 315i, Cond 330i and Cond 340i Professional case with built-in measuring set-up and separate compartment for measuring cell and accessories meter with batteries Measuring cell as chosen KCl solution 0.01 mol/l for system checks Stand and measuring beaker Plug-in power supply (only Cond 340i) Operating instructions Technical Data Model Cond 315i Cond 330i Cond 340i Measuring range/ 0.0 µs/cm 500 ms/cm 0.0 µs/cm 500 ms/cm resolution with 5 ranges in 5 ranges or AutoRange in AutoRange 0.00 µs/cm µs/cm (for K=0.1 cm -1 ) 0.00 µs/cm µs/cm µs/cm µs/cm (for K=0.01 cm -1 ) (for K=0.1 cm -1 ) Temperature -5.0 C C -5.0 C C Salinity TDS mg/l Resistivity MΩcm MΩcm 80 Accuracy ±0,5 % of value ±0.5 % of value (±1 digit) Temperature ±0.1 K ±0.1 K Ref. temperature T ref 25 C 20 or 25 C, selectable Cell constant Fixed cm -1, 0.1 cm cm cm -1 and 0.01 cm -1 fixed and cm -1 and cm -1 adjustable Temperature Automatic, can be switched off Automatic, can be switched off compensation Temperature- Non-linear function for natural waters (nlf) Non-linear function for natural waters (nlf) coefficient to EN (DIN ) and to EN (DIN ) and ultrapure water function ultrapure water function Linear compensation from %/K No compensation No compensation Display LCD display 60 x 45 mm visible area, simultaneous display of measurement, temperature and special characters Data storage 500 data sets (measurement, temperature, date/time, identity no.); time-controlled storage at 7 intervals 5 s min, non-volatile data storage Data output Via display Via display or interface Interface Self-configuring analog output V corresponding to display, or RS 232 bi-directional interface Operating time Mains operation Continuous operation from mains supply Battery operation = h* with 4 x 1.5 V batteries with AutoSwitchOff after 1 h (except logger operation) *depending on conductivity Protection type IP 66 and IP 67 to IEC 529 Dimensions 172 x 80 x 37 mm (H x B x D) Weight Approx. 300 g Certified to CE, TÜV/GS, UL and/or cetlus, CUL Warranty 3 years for the instrument
6 Handheld Meters & Field measuring kit according to USP 24, with stainless steel flow-thru vessel for pharmaceutical water (see page 95). General Oxygen (D.O.) ISE ORP ph Ordering Information Handheld Meters Cond 315i Robust and waterproof battery-operated handheld conductivity meter 2C Cond 330i Robust and waterproof battery-operated handheld conductivity meter with datalogger 2C Cond 340i Robust and waterproof battery-operated handheld conductivity meter with datalogger 2C and serial interface Cond 340i Robust and waterproof handheld conductivity meter with datalogger and serial interface, 2C for mains operation Respiration BOD Multi- Parameter Ordering Information SETs Handheld Meters SETs Cond 315i Handheld conductivity meter, including conductivity cell, professional case and accessories 2C Cond 330i Handheld conductivity meter, including conductivity cell, professional case and accessories 2C Cond 340i Handheld conductivity meter, including conductivity cell, professional case and accessories 2C Cond 340i Handheld conductivity meter with mains power supply, including conductivity cell, professional case and accessories2c cells please select one TetraCon electrode conductivity measuring cell 1 TetraCon electrode conductivity measuring cell with 3 m cable 2 LR 325/01 Ultrapure water conductivity cell 4 Sample Preparation Colony Counter Photometry Turbidity SET ordering example Cond 330i + TetraCon conductivity cell 2C Note: Other conductivity cells in SET and instrument versions for 120 VAC/60 Hz are available on request 2 Software, Printers Please refer to page 88 for conductivity cells and page 94 ff. for other accessories Customer Service 81
7 General Information about portable conductivity meters can be found on pages Meters Portable Meters ProfiLine LF 197 and ProfiLine LF 197-S Robust Shockproof Waterproof Portable Reliable Standard conductivity measurement and conductivity measurement at depths down to 100 m WTW portable conductivity meters The WTW conductivity meters of the ProfiLine LF 197 series are both hose-proof (IP 66) and submersible (IP 67). They convince because of their high degree of operator comfort and foolproof operator guidance via the large multifunctional display. They are equipped with a carrying/support handle and carrying strap as standard. The portable conductivity meters are available in 2 versions: ProfiLine LF 197: ProfiLine conductivity meter, extremely robust, hose-proof (IP 66) and submersible (IP 67), for connection of TetraCon electrode measuring cells and depth armature TA 197 LF with up to 100 m cable, with large multifunctional display for temperature and measurement, automatic temperature compensation, selectable reference temperature of 20 C or 25 C, built-in memory, TDS and salinity measurements, RS 232 digital output, integrated carrying and support handle, built-in electrode storage sleeve, for rechargeable battery and mains operation, and including plug-in power supply and carrying strap ProfiLine LF 197-S: As ProfiLine LF 197 but with 2 analog outputs corresponding to display for conductivity and temperature values 82 IP 66 IP 67 Year 3 Warranty
8 Portable Meters & Field Accessories for conductivity measurement at depths down to 100 m depth armature TA 197 LF with built-in temperature sensor, up to 100 m cable with waterproof plug (IP 67), pressure-resistant steel armoring (material VA ) with screw-off protective hood, pressure-resistant to max. 10 bar, fits into 2" boreholes Technical Data Model ProfiLine LF 197 ProfiLine LF 197-S Measuring range/ 0.0 µs/cm ms/cm in 5 ranges, additional µs/cm (at K=0.1 cm -1 ) resolution Temperature C/ ±0.1 K Salinity TDS mg/l Accuracy ±0.5% of value (± 1 digit) Temperature ±0.1 K Ref. temperature 20 C or 25 C, selectable Cell constant 0.1 cm -1 fixed and cm -1, adjustable Temperature Automatic or manual compensation Temperature Non-linear function for natural waters to EN (DIN ) coefficient Linear compensation from %/K No compensation Display LCD display 60 x 35 mm visible area, simultaneous display of measurement, temperature, special characters Data storage Ring memory for 50 pairs of measurements (measurement, temperature) with data protection Data output Via display or interface Interface Unidirectional RS 232 interface Unidirectional RS 232 interface 2 analog recorder outputs for measurement and temperature output corresponding to display Operating time Continuous operation from plug-in mains supply; or hours with rechargeable batteries (depends on conductivity) with AutoSwitchOff after 1 h Protection type IP 66 and IP 67 to IEC 529 Dimensions 230 x 185 x 90 mm (B x D x H) Weight Approx. 1.5 kg Certified to CE, TÜV/GS, UL, CUL Warranty 3 years for the instrument Ordering Information Portable conductivity meters ProfiLine LF 197 Robust, waterproof, submersible conductivity meter ProfiLine LF 197-S As ProfiLine LF 197, but additionally with 2 analog recorder outputs Note: 120 VAC / 60 Hz versions on request Depth armatures for conductivity measurements with ProfiLine LF 197 and ProfiLine LF 197-S 4-electrode conductivity depth armatures with built-in temperature sensors, cable (length optional) with waterproof plug (IP 67), VA steel armoring and screw-off protective hood, pressure resistant to max. 10 bar, fits into 2 boreholes Cable length Cable length TA 197 LF m TA 197 LF m TA 197 LF m TA 197 LF m Please refer to page 88 for conductivity cells and page 94 ff. for other accessories General ISE ORP ph Oxygen (D.O.) Respiration BOD Multi- Parameter Sample Preparation Colony Counter Photometry Turbidity Software, Printers Customer Service 83
9 84 General Information about inolab laboratory instruments can be found on pages Performance-oriented instrument range Simplified operator convenience Mainsindependent Suitable as bench and wall-mounted models Country-specific units ISO-conform documentation Application-oriented displays Meters Meters inolab Cond Level 1, inolab Cond Level 2, inolab Cond Level 3 inolab Level 1 inolab Cond Level 1: simple and reliable Routine laboratory conductivity meter with large multifunctional display, parallel temperature display and automatic temperature compensation. 20 C or 25 C can be set as reference temperature. Both TDS and salinity measurements are possible as well as conductivity and temperature. The ability to set different cell constants means that other special conductivity cells can be connected as well as the TetraCon electrode conductivity cell and LR 325/01 ultrapure water conductivity cell (see page 93). inolab Level 2 inolab Cond Level 2: compact and communicative Standard laboratory conductivity meter with large multifunctional display, parallel temperature display and automatic temperature compensation. An integral measurement store with logger function and a real-time clock allow QA-conform data acquisition. The optional built-in printer allows data printout on thermal paper accepted for use in official documents. 20 C or 25 C can be set as reference temperature. Both TDS and salinity measurements are possible as well as conductivity and temperature. The ability to set different cell constants means that other special conductivity cells can be connected as well as the TetraCon electrode conductivity cell and LR 325/01 ultrapure water conductivity cell (see page 93). Think innovative MultiCal automatic calibration AutoRead automatic drift control for stable and reproducible measurements See innovative Feed and on/off keys keys for controlling the built-in printer Year IP 43 3 Warranty
10 inolab Level 3 inolab Cond Level 3 with Teminal Level 3 or PC software: flexible and powerful Touch innovative High-performance laboratory conductivity meter with graphics display and digital recorder function, parallel display of temperature and automatic temperature compensation. An integral measurement store with logger function and a real-time clock allow QA-conform data acquisition. The optional built-in printer allows data printout on thermal paper accepted for use in official documents. 20 C or 25 C can be set as reference temperature. Both TDS and salinity measurements are possible as well as conductivity and temperature. The ability to set different cell constants means that other special conductivity cells can be connected as well as the TetraCon electrode conductivity cell and LR 325/01 ultrapure water conductivity cell (see page 93). An PC keyboard interface allows an external keyboard or a barcode reader to be connected. Meters & Field General ISE ORP ph Oxygen (D.O.) AutoRead automatic drift control for stable and reproducible measurements RUN/ENTER triggers the measuring process Year IP 43 3 Warranty Terminal Level 3 Built-in digital plotter Graphic evaluation possible Connection of bar-code reader or PC keyboard Automatic memory function if bar-code reader is used Selectable instrument language Extended GLP functions Limit input with acoustic alarm Meets all the requirements of USP 24 Free-of-charge software downloads for inolab pilot or terminal Respiration BOD Multi- Parameter Sample Preparation Colony Counter Photometry Turbidity Software, Printers Customer Service 85
11 Technical Data for laboratory conductivity meters Modelle Cond Level 1 Cond Level 2 Cond Level 3 Range/ 0.0 µs/cm ms/cm Resolution in 5 measuring ranges or AutoRange additionally for K = 0.1 cm -1 : 0.00 µs/cm µs/cm K = 0.01 cm -1 : µs/cm µs/cm Temperature C Salinity TDS: mg/l Resistivity: MΩcm Accuracy ±0.5% of value (±1 digit) Temperature ±0.1 K Reference 20 C or 25 C, selectable temperature Cell constants cm -1, 0.1 cm -1 and 0.01 cm -1 fixed, freely selectable cm -1 and cm -1 Temperature Automatic, manual or switched off compensation Temperature Non-linear function for natural water to EN (DIN ) coefficient Linear compensation from %/K No compensation Calibration With 0.01 mol KCl Real-time clock Non-volatile Data memory 200 records 2000 records (measurement, temperature) (measurement, temperature) date/time, ident. no., time-controlled date/time, ident. no., time-controlled storage interval 5 s min storage interval 1 s days Data output Display Display or interface Display, PC or interface Analog interface Self-configuring as analog output corresponding to display or as RS 232 bidirectional interface Digital interface RS 232 bidirectional interface Operating time/ 2500 h with 4 x 1.5 V standard batteries With terminal: universal plug-in power Energy supply or mains supply supply 230 VAC or 120 VAC Without terminal: via PC interface Protection type IEC 529 / IP 43 without built-in printer Dimensions 230 x 210 x x 250 x x 250 x 70 (B x D x H in mm) Weight Approx. 1.3 kg Approx. 1.6 kg Approx. 1.6 kg Certified to CE, TÜV/GS, UL, CUL Warranty 3 years for the instrument 86
12 Meters General & Field Ordering Information for inolab conductivity meters inolab laboratory conductometers inolab Cond Level 1 Simple and reliable conductometer for routine work 1C inolab Cond Level 2 Compact precision conductometer with serial interface 1C inolab Cond Level 2 Compact precision conductometer with additional 1C built-in printer for GLP-conform documentation inolab Cond Level 3 Flexible and powerful precision the intelligent conductivity measuring place 1C consisting of multifunction box and universal terminal, with PC software/connection cable inolab Cond Level 3 The intelligent conductivity measuring place with additional built-in printer 1C inolab Cond Level 3 The integrated conductivity measuring place with PC software/connection cable; without printer/terminal 1C ISE ORP ph Oxygen (D.O.) Ordering Information for inolab conductivity meters SETs ready to go inolab Cond SETs inolab Cond Level 1 Including cell, passive multifunction box and accessories 1C inolab Cond Level 2 Including cell, passive multifunction box and accessories 1C inolab Cond Level 2 Including built-in printer, cell, passive multifunction box and accessories 1C inolab Cond Level 3 Including terminal, cell and accessories 1C inolab Cond Level 3 With built-in printer, including terminal, cell and accessories 1C inolab Cond Level 3 Without printer/terminal, with PC software/connection cable, cell and accessories 1C Respiration BOD Multi- Parameter cells please select one TetraCon electrode conductivity measuring cell TetraCon electrode conductivity measuring cell with 3 m cable LR 325/01 Ultrapure water conductivity cell Sample Preparation SET ordering example inolab Cond Level 1 + conductivity measuring cell LR 325/01 1C Note: Other measuring cells in SET and instrument versions for 120 VAC/60 Hz are available on request Colony Counter Please refer to page 88 for conductivity cells and page 94 ff. for other accessories Photometry Customer Service Software, Printers Turbidity 87
13 cells Meters TetraCon TetraCon conductivity cells For more than 50 years WTW has been one of the leading manufacturers worldwide of precision conductivity meters and cells. The TetraCon 4-electrode system is the perfect result of a logical, practice-oriented further development and sets a new standard for professional conductivity measurements. In comparison with conventional measuring cells with 2 electrodes, the TetraCon conductivity cell offers numerous technical advantages: Highest degree of precision and linearity by optimized cell geometry Extremely large measuring range with just one cell Long-term cell constant stability with high-quality abrasion-resistant graphite electrodes With built-in temperature sensor as standard Smallest immersion depth possible Ideal sample exchange no dead volume No measuring errors even with very dirty electrode contact resistance on the electrode surface is automatically compensated No measuring errors from cable influences No measuring errors from primary or secondary polarization effects No measuring errors from alteration to the electrical marginal field during contact with base or side walls No danger of breakage owing to robust epoxy casting technique Special conductivity depth armatures for ProfiLine LF 197 and ProfiLine LF 197-S can be found on page 83 88
14 Cells & Field Oxygen (D.O.) General ISE ORP ph Standard conductivity cell TetraCon 325 Special conductivity cell TetraCon 325/Pt Special conductivity cell TetraCon 325/S Ultrapure water conductivity cell LR 325/01 Respiration BOD Multi- Parameter 4-electrode cell with built-in temperature sensor Electrode material graphite Shaft material epoxy Shaft length 120 mm Cell constant K = cm -1 Diameter 15.3 mm Cable length 1.5 m Measuring range 1 µs/cm... 2 S/cm* Temperature range C 4-electrode cell made of glass with built-in temperature sensor. For universal use, even in partially aqueous or highly aggressive media. Electrode material platinum Shaft length 120 mm Cell constant K approx. 1 cm -1 Diameter 20 mm Cable length 1.5 m Measuring range 1 µs/cm... 1 S/cm* 4-electrode cell with built-in temperature sensor for measurements in pastes, creams and emulsions Electrode material graphite Shaft material epoxy Shaft length 120 mm Cell constant K = cm -1 Diameter 15.3 mm Cable length 1.5 m Measuring range 1 µs/cm... 2 S/cm* Sample Preparation Colony Counter Photometry Turbidity Software, Printers Customer Service With built-in temperature sensor and flow-thru vessel D 01/T for the measurement of small conductivities (<1 µs/cm), e.g. boiler feed water or deionized water. Electrode material V4A steel Shaft material V4A steel Shaft length 120 mm Cell constant K = 0.1 cm -1 Diameter 12 mm Cable length 1.5 m Min./max. immersion depth 35/110 mm and flow-thru measurements Measuring range µs/cm µs/cm * Measuring range depends on particular instrument 89
15 flow-thru cell TetraCon DU/T measuring cell LDM 4-electrode cell with built-in temperature sensor for standard applications in laboratories and production. Connection via 10 mm dia. hose nozzles. For small sample volumes with injection syringe for sampling Cell constant K approx. 150 cm -1 Trace conductivity cell LR 325/001 With built-in temperature sensor and flow-thru vessel for the measurement of conductivity and resistance in boiler feed water or deionized water as well as in partially aqueous and nonaqueous media. Flow-thru vessel Electrode material Shaft material Shaft length V4A steel V4A steel V4A steel 120 mm Electrode material graphite Shaft material epoxy Length 155 mm Filling volume 7 ml Cell constant K = cm -1 Measuring range 1 µs/cm... 2 S/cm* Adapter cable KKDU 325, length 1 m, is necessary for the connection. Dialysis conductivity cell TetraCon DU/TH As TetraCon DU/T, but for dialyzers with connectors to DIN (Hansen connectors). Adapter cable KKDU 325, length 1 m, is necessary for the connection. flow-thru cell LDM/S For column chromatography or minute sample volumes. Cell constant K approx. 15 cm -1 Adapter cable K-LDM with built-in 30 kω fixed resistor is necessary for the connection. Volume approx. 4 ml Temperature C Cell constant K = 0.01 cm -1 Diameter 20 mm Cable length 1.5 m Min./max. immersion depth 35/110 mm and flow-thru measurements Measuring range µs/cm µs/cm 90 * Measuring range depends on particular instrument
16 Selection Guide & Field General Selection Guide Measuring cell LF 90 LF 95 LF 96 LTA LTA LTA LTA LTA LTA/S LTA/KS LR 01/T LR 001/T LDM 3 LDM/S 3 KLE 1 KLE 1/T KLE 315 TetraCon 96 TetraCon 96-1,5 TetraCon 96-A- TetraCon 96 A-4 TetraCon 96-T-100 m TetraCon 325 TA 197 LF TetraCon L TetraCon 325/Pt TetraCon DU/T TetraCon DU/TH KDU 1/T KDU 1/TH LR 325/01 LR 325/001 * TetraCon 325/S Adapter (possible conversion with cell constants) is required: 1 Adapter cable KLF 10 2 Adapter cable K/LTA together with temperature sensor TFK 325 or TFK Adapter cable K/LDM 4 Connection cable KKDU 5 Connection cable KKDU 325 * not for Cond 315i Customer Service LF 315 LF 318 LF 320/323/325 LF 330/340A Cond 315i/330i/340i ISE ORP ph Oxygen (D.O.) Respiration BOD Multi- Parameter Sample Preparation Colony Counter Photometry Software, Printers inolab Cond, ph/cond, Multi Turbidity LF 537 LF 538 LF 539 LF 3000 MultiLab 540 MultiLab P4/P5 MultiLine P4, Multi 340i MultiLine P3 ph/lf, ph/cond 340i LF 196 LF 197 LF
17 Ordering Information Standard conductivity cells KLE electrode conductivity cell with 1.5 m cable and waterproof plug TetraCon electrode conductivity cell with built-in temperature sensor, K = cm with waterproof plug (IP 68) and 1.5 m cable TetraCon As TetraCon 325, but cable length 3 m LTA 1 Glass/platinum 2-electrode conductivity cell, K approx. 1 cm (adapter cable K/LTA required) LTA 100 Glass/platinum 2-electrode conductivity cell with adjustable cell constant, K = 1 cm (adapter cable K/LTA required) TetraCon 96 4-electrode conductivity cell with built-in temperature sensor, K = cm -1, 1 m cable TetraCon L Glass/platinum 4-electrode conductivity cell with built-in temperature sensor, K approx. 1.0 cm -1, for universal use, even in partially aqueous or highly aggressive inorganic media. TetraCon 325/Pt Glass/platinum 4-electrode conductivity cell with built-in temperature sensor; can also be used in partially aqueous or highly aggressive solutions, K approx. 1 cm -1 For conductivity measurements at depths down to 20 m TetraCon As TetraCon 325, but cable length 6 m TetraCon As TetraCon 325, but cable length 10 m TetraCon As TetraCon 325, but cable length 15 m TetraCon As TetraCon 325, but cable length 20 m Suitable accessories A 325/K Plastic armoring with protective hood A 325/S Steel armoring with stainless steel protective hood, material no For conductivity measurements at depths down to 100 m TA 197 LF-25 4-electrode conductivity depth cell with built-in temperature sensor, 25 m cable with waterproof plug (IP 68), pressure resistant steel armoring and screw-off protective hood, fits into 2 boreholes TA 197 LF-40 As TA 197 LF-25, but with 40 m cable TA 197 LF-60 As TA 197 LF-25, but with 60 m cable TA 197 LF-100 As TA 197 LF-25, but with 100 m cable Ordering Information Flow-thru conductivity cells TetraCon DU/T Flow-thru cell with built-in temperature sensor for all standard applications in laboratories and production, connection via 10 mm dia. hose nozzles, K = cm -1, without cable TetraCon DU/TH Flow-thru cell with built-in temperature sensor for checking dialyzers, connection via DIN Hansen connectors, K = cm -1, without cable LDM/S flow-thru cell for column chromatography or minute sample volumes, K = approx. 15 cm -1 KDU 1/T flow-thru cell with built-in temperature sensor, for all standard applications in laboratories and production, connection via 10 mm dia. hose nozzles, K approx cm -1, without cable KDU 1/TH Flow-thru cell with built-in temperature sensor for checking dialyzers, connection via DIN Hansen connectors, K approx cm -1, without cable 92
18 Ordering Information cells for special applications Pure and ultrapure water measurements Cells LR 325/01 Ultrapure water cell with built-in temperature sensor, K = cm -1, with flow-thru vessel D 01/T and waterproof plug LTA 01 Glass/platinum 2-electrode conductivity cell for ultrapure water, K approx. 0.1 cm LR 01/T Ultrapure water cell with built-in temperature sensor, with flow-thru vessel D 01/T as standard, K = cm -1, with 1.5 m cable and waterproof plug LR 001/T Trace conductivity cell with built-in temperature sensor and flow-thru vessel for the measurement of conductivity in boiler feed water or deionized water as well as in partially aqueous and non-aqueous media, K = cm -1, with 1.5 m cable LR 325/001 Trace conductivity cell with built-in temperature sensor and flow-thru vessel for the measurement of conductivity in boiler feed water or deionized water as well as in partially aqueous and non-aqueous media, K = cm -1, cable with waterproof plug measurements in pastes and emulsions TetraCon 325/S 4-electrode conductivity cell for pastes and emulsions with built-in temperature sensor, K = cm -1, with waterproof plug and 1.5 m cable LTA/KS 2-electrode conductivity cell for pastes, K = cm Special applications LDM measuring cell for small sample volumes with injection syringe for sampling, K = approx. 150 cm -1, without cable LTA 10 Glass/platinum 2-electrode conductivity cell for extremely high conductivity values, K approx. 10 cm LTA Glass/platinum 2-electrode conductivity cell with special length, suitable for measurements in test tubes (13 mm dia.), K = approx. 1 cm -1 Connection cables and accessories KLF 10 Adapter cable for connection of 2-electrode conductivity cell and TFK K/LTA Adapter cable for connection of 2-electrode conductivity cell and TFK or TFK 150 K-LDM Adapter cable with built-in 30 kohm fixed resistor, length 1 m KKDU Connection cable with 1 m cable KKDU 325 Connection cable with waterproof plug and 1 m cable TH 340 Telescopic extension for TetraCon , m, with sensor holder Protective armoring for safe on-site use 1 SM 325 Shock-absorbing, rubber protective armoring with folding support and sensor cable clamping device 2 TG/Oxi-LF Sleeve set, suitable for SM 325 protective armoring, consisting of electrode sleeve, holding device and additional carrying strap for field use. Can also be used for storing the sensor. 3 FM 325/Oxi-LF Field armoring, specially designed for rough use on-site and in industry, extremely robust and shock-resistant thanks to protective armoring with integrated electrode sleeve, carrying handle and additional carrying strap with holding device, sensor cable clamping device and folding support for laboratory measurements & Field General ISE ORP ph Oxygen (D.O.) Respiration BOD Multi- Parameter Sample Preparation Colony Counter Photometry Turbidity Ordering Information Protective armoring SM 325 Shock-absorbing, rubber protective armoring TG/Oxi-LF Sleeve set, suitable for protective armoring SM FM 325/Oxi-LF Field armoring, specially for rough conditions Software, Printers Customer Service 93
19 Software and printers Information is given on pages Meter Meters Accessories page Protective armoring 93 Flow-thru vessels 94 Stands and cell holders 94 Calibration and testing agents 95 Flow-thru vessels Ordering Information for LTA 1, LTA, LTA 01 and TFK 530 D 530 Flow-thru vessel of transparent PVC, suitable for conductivity cells and temperature sensors, I.D. 44 mm, V*=97 ml for TetraCon 325 D 201 Flow-thru vessel of transparent PVC, I.D. 18 mm, V*=13 ml for TetraCon 96-1,5, TetraCon 96 and KLE 1 D 1/T Flow-thru vessel, glass I.D. 24 mm, V*=36 ml for LR 01/T and LTA 01 D 01/T Flow-thru vessel, glass I.D. 18 mm, V*=17 ml for LTA 100 D 100 Flow-thru vessel I.D. 27 mm, V*=40 ml V*: filling volume without sensor Stand and cell holder Stand STH 650 Benchtop stand with flexible electrode holder for measuring cells and temperature sensors 94 Ordering Information Benchtop stand and cell holder STH 650 Benchtop stand with flexible electrode holder for ph electrodes, ion sensitive electrodes, reference electrodes, temperature sensors, oxygen sensors and TetraCon 325 conductivity cells
20 Meter Accessories & Field Calibration and testing agents General Kit for measuring the conductivity according to USP 24 This kit contains LR 325/01 Ultrapure water cell, D01/T Flow-thru vessel made of glass (USP-KIT 1) or stainless steel (USP-KIT 2), NIST traceable 15 µs standard with accuracy ±2% and 6R/SET/LabTesting set NEW ISE ORP ph Calibration standard 100 µs/cm Shelf life 2 years, NIST traceable with accuracy ±3% Calibration standard 15 µs/cm Shelf life 1 year, NIST traceable with accuracy ±2% Ordering Information Kit for measuring the conductivity according to USP 24 USP Kit 1 Kit for measuring the conductivity according to USP 24, consisting of LR 325/01 Ultrapure water cell, D01/T Glass flow-thru vessel, NIST traceable 15 µs standard with accuracy ±2% and 6R/SET/LabTesting set USP Kit 2 As USP Kit 1, but flow-thru vessel made of stainless steel instead of D01/T Calibration agents KS 100µS Calibration standard 100 µs/cm, shelf life 2 years, NIST traceable with accuracy ±3% (300 ml) KS 15µS Calibration standard 15 µs/cm, shelf life 1 year, NIST traceable with accuracy ±2% (300 ml) EP/SET Calibration and platinization set (6 x 50 ml bottles calibration and control standard, KCl 0.01 mol/l, 30 ml platinizing solution, 1 calibration vessel), only for platinized cells E/SET Calibration set (6 x 50 ml bottles calibration and control standard, KCl 0.01 mol/l) Testing agents for conductivity meters 6R/SET/LAB 1 Testing set for checking the conductivity meters according to ISO Allows the measured values to be traced back to national standards. Only for LF 3000, LF 539, LF 537 and MultiLab P4/P5 6R/SET/LAB 2 Testing set for checking the conductivity meters according to ISO Allows the measured values to be traced back to national standards. Oxygen (D.O.) Respiration BOD Multi- Parameter Sample Preparation Colony Counter Photometry Turbidity Software, Printers Customer Service 95
Conductivity measurement
Conductivity measurement Content 95 Applications and meters overview 96 Benchtop conductivity meters 96 inolab Multi IDS digital 97 inolab analogue 100 Portable conductivity meters 100 MultiLine IDS digital
More informationMulti-parameter measurement
LAB & FIELD INSTRUMENTATION > Parameter > Multi-parameter measurement Multi-parameter measurement Content 23 Applications and meters overview 24 The IDS World 26 IDS goes wireless - freely connected 28
More informationinolab Multi IDS ph, ISE, CONDUCTIVITY AND DISSOLVED OXYGEN MEASUREMENT ACCURATE, COMPLIANT, SECURE
inolab Multi IDS ph, ISE, CONDUCTIVITY AND DISSOLVED OXYGEN MEASUREMENT ACCURATE, COMPLIANT, SECURE Redefined IDS The IDS concept from WTW. Intelligent, digital sensors for standard parameters ph, conductivity,
More informationHD HD HD HD HD
HD2205.2 - HD2206.2 - HD2256.2 - HD2259.2 - HD22569.2 Introduction The instrument series HD2205.2, HD2206.2, HD2256.2, HD2259.2, and HD2569.2 is made up of bench top instruments for electrochemical measures:
More informationThermo Scientific Orion Star A111 ph Benchtop Meter
Orion Star A Meters Thermo Scientific Orion Star A111 Benchtop Meter Thermo Scientific Orion Star A111 Benchtop Meters combine simplicity with accuracy for dedicated applications. A large LCD displays
More informationJUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor
sales@jumo.co.uk info.us@jumo.net Vorläufig V Page 1/8 JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor Cell constants K = 0.01 1.0 202922 Series for universal application, e.g.
More informationDrinking water monitoring
Drinking water monitoring Ready-to-use systems for monitoring of quality relevant parameters in drinking water Pre-assembled Ready for use Flexible and multi-purpose Single-parameter Systems Single-parameter
More informationContents. Publisher. Contents. page. Publisher 1. New Instruments 2 7. MultiLine IDS General Description of Meters 16 21
Contents Contents page Publisher 1 New Instruments 2 7 MultiLine IDS 8 15 General Description of Meters 16 21 Laboratory Meters inolab 16 17 Portable Field Meters ProfiLine 18 Portable Meters 19 20 VARIO
More informationBedienungsanleitung Operating manual Mode d emploi Instrucciones de operación
Bedienungsanleitung Operating manual Mode d emploi Instrucciones de operación ba7542defs M PRT CAL STO O ESC Universal-Taschenmessgerät Seite 3 Universal Pocket Meter Page 7 Instrument de poche universel
More informationCOND 200. Conductivity/TDS/Salinity Meter Operating instructions. Meas Cal. Hold Rcl Store. On Off Menu
COND 200 Conductivity/TDS/Salinity Meter Operating instructions Meas Cal Hold Rcl Store On Off Menu 2 Table of Contents Page 1. Scope of delivery...4 2. System description...4 3. Connections...6 4. Display...6
More informationINSTRUCTION MANUAL DISSOLVED OXYGEN-METER MODEL CDO-01
INSTRUCTION MANUAL DISSOLVED OXYGEN-METER MODEL CDO-01 EL-221, MIDC Electronic Zone, Mhape, Navi Mumbai-400710. Tel: 022- 61393000 CHAPTER 1 INTRODUCTION Contech CDO-01 measures Dissolved Oxygen and temperature
More informationHandheld meter Cond 330i/340i
Operating manual Handheld meter Cond 330i/340i 5 3 0 M Tref25 nlf 2 5 0 AR S/cm C TP CAL STO O AR Conductivity measuring instrument ba52302e04 03/2008 Cond 330i/340i Accuracy when going to press The use
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationAnalytical Transmitters
Analytical Transmitters THORNTON Leading Pure Water Analytics M300 Transmitters Conductivity / Resistivity ph / ORP Dissolved Oxygen Dissolved Ozone Flow / Total Flow M300 Transmitters for Comprehensive
More informationOperating manual. Multi 340i. mg/l. ARng. ph/dissolved Oxygen/Conductivity Measuring Instrument. ba52318e02 03/2004
Operating manual Multi 340i O 7 9 2 M 1 7 6 ARng C TP mg/l STO CAL O AR ph/dissolved Oxygen/Conductivity Measuring Instrument ba52318e02 03/2004 Accuracy when going to press The use of advanced technology
More informationConductivity Transmitter
Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationMeasuring and Controlling Unit Multronic OC
Measuring and Controlling Unit Multronic OC One channel measuring and controlling unit for ph / conductivity / Chlorine measuring Automatic temperature compensation Measuring and control behaviour simultaneously
More informationOperating manual handylab multi 12 g/l ARng ph/dissolved Oxygen/Conductivity Measuring Instrument
Operating manual ba75371e handylab multi 12 O 7 9 2 M 1 7 6 ARng C TP mg/l STO CAL O AR ph/dissolved Oxygen/Conductivity Measuring Instrument ba75371e01 11/2002 Accuracy when going to press The use of
More informationConductivity-Converter
Conductivity-Converter compact version separate version Condutec-LF / e Technical Information Operating Instructions Hengesbach GmbH & Co. KG * Schimmelbuschstr. 17 * D-40699 Erkrath * Tel.: +49 (0) 21
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationCondumax W CLS15 and CLS15D
Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationBlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells
D-42607 Solingen Postfach 10 07 08 D-42659 Solingen Ritterstr. 87-89 Phone +49 212 81 40 45-46 Fax +49 212815500 e-mail: mail@juchheim-solingen.de Internet: www.juchheim-solingen.de Data Sheet 20.2922
More informationB Operating Instructions V1.00/EN/
Conductive conductivity/ultra-pure water sensors with a 2-electrode system, types 202922, 202923, 202924, 202925 Glass conductivity sensors, type 202922/30 Diaphragm tubes, type 201083 Compensation thermometer,
More informationOperating manual. ph/oxi 3400i. mg/l. ARng. ph/oxygen measuring instrument. ba75686e01 01/2007
Operating manual ph/oxi 3400i O 7 9 2 M 1 7 6 ng C TP mg/l STO CAL O ph/oxygen measuring instrument ba75686e01 01/2007 Accuracy when going to press The use of advanced technology and the high quality standard
More informationWATERPROOF CONDUCTIVITY METER CC- 411 USER S MANUAL
WATERPROOF CONDUCTIVITY METER CC- 411 USER S MANUAL USER S MANUAL WATERPROOF CONDUCTIVITY METER CC-411 Before use please read the instruction carefully. CONTENTS I. INTRODUCTION 1 1. Exploitation notices
More informationHandheld meter Oxi 3300i/3400i
Operating manual Handheld meter Oxi 3300i/3400i O 7 9 2 M 1 7 6 ARng C TP mg/l STO CAL RCL O AR Oxygen measuring instrument ba75683e02 03/2008 3300i/3400i Accuracy when going to press The use of advanced
More informationType PLC Fitting. Valve for Continuous control. Diaphragm valve. Output
Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationMeasuring and Controlling Unit Multronic
Measuring and Controlling Unit Multronic Modular system Up to 3 measurement variables with control functions in one housing Free combination of the measurement variables ph / Redox / temperature / conductivity
More informationHandheld meter Cond 3150i
Operating manual Handheld meter Cond 3150i 5 3 0 Tref25 nlf 2 5 0 S/cm C TP AR O Conductivity measuring instrument ba75681e01 01/2007 Accuracy when going to press The use of advanced technology and the
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationOperating manual. handylab LF 12. Tref25 nlf C TP STO O RCL. Conductivity Meter. ba75367d04 01/2011
Operating manual handylab LF 12 5 3 0 M Tref25 nlf 2 5 0 AR S/cm C TP STO CAL O AR Conductivity Meter ba75367d04 01/2011 handylab LF 12 Accuracy when going to press The use of advanced technology and the
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationDN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)
Products Handheld Measuring Instruments Digital PIEZOVAC Sensor PV 101 Digital THERMOVAC Sensor TM 101 The digital compact PIEZOVAC PV 101 and THERMOVAC TM 101 combine high-quality sensor technology with
More informationCondumax CLS15 and CLS15D
Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationProcess ph/orp Analysis Systems
Process ph/orp Analysis Systems A SAMPLER OF SAMPLERS The HORIBA K-8 process ph (ORP) analysis system features a systematic combination of functional component units which offers the versatility needed
More informationCondumax CLS21 and CLS21D
Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:
More informationConductivity Analyzer
Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures
More informationTechnical Information Smartec CLD18
TI01080C/07/EN/02.14 71264779 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring
More informationCondumax CLS15 and CLS15D
Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More information( F L O W I Z F A M I L Y )
THE MOST ACCURATE BATTERY POWERED SYSTEM ( F L O W I Z F A M I L Y ) E l e c t r o m a g n e t i c c o n v e r t e r p o w e r e d b y b a t t e r i e s, s o l a r p a n e l o r D C p o w e r w i t h 4
More informationSignet 9950 Dual Channel Transmitter
Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationParts Per Million Dissolved Oxygen Systems
Parts Per Million Dissolved Oxygen Systems Model 900 Portable s Model 9100 Model 9200 Model 9300 The Royce line of PPM level dissolved oxygen (DO) analyzers is the largest, most varied line in the world.
More informationC4E NUMERICAL SENSOR User manual
C4E NUMERICAL SENSOR User manual Distributed & Supported By: Edaphic Scientific Pty Ltd www.edaphic.com.au info@edaphic.com.au Ph: 1300 430 928 1 Version 1.0 CONTENTS 1. GENERAL...3 2. CHARACTERISTICS...4
More informationAnalog outputs (option) Output 1 + 2: 0(4) 20 ma or 0 10 V
Page / JUMO AQUIS 500 CR Transmitter/Controller for conductivity, TDS, resistivity and temperature Compliant with USP Brief description The instrument is used for the conductive measurement/control
More information- HD HD HD pag. 338 Portable ph meters. - HD HD pag. 342 Portable ph and conductivity meters
- HD 2105.1 - HD 2105.2 - HD 2305.0 pag. 338 Portable ph meters - HD 2156.1 - HD 2156.2 pag. 342 Portable ph and conductivity meters - HD 9609 pag. 345 Portable ph Simulator - DO 9403T-RI - DO9785T - DO
More informationB Operating Instructions /
Conductivity/ultra-pure water measuring cells with a twin-electrode system Types 202922, 202923, 202924 and 202925 Glass conductivity cells, type 201080 Diaphragm tubes, type 201083 Compensation thermometer,
More informationTechnical Information Condumax CLS15D/CLS15
TI0009C/07/EN/4.4 7268306 Products Solutions Services Technical Information Condumax CLS5D/CLS5 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 0.0 cm or k = 0. cm Application
More informationTechnical Information Memosens CLS82D
TI01188C/07/EN/03.16 71318348 Products Solutions Services Technical Information Memosens CLS82D Hygienic conductivity sensors, digital with Memosens technology, cell constant k = 0.57 cm -1 Application
More informationSeven2Go. Everywhere You Measure ph Quality Measurement Made Mobile. Seven2Go. ph / ORP Conductivity Ion Concentration Dissolved Oxygen
Seven2Go Seven2Go ph / ORP Conductivity Ion Concentration Dissolved Oxygen Everywhere You Measure ph Quality Measurement Made Mobile The World of Mobile ph Your Mobile Lab, Wherever You Go The New Seven2Go
More informationOperating manual Cond 1970i Portable conductivity measuring instrument
perating manual N / FF M CAL AUT READ RUN / ENTER Tref25 5 30 2 5 0 nlf ARng /cm C REL1 TP RCL T Portable conductivity measuring instrument ba75692e01 01/2007 Accuracy when going to press The use of advanced
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications 2- or 4-electrode technology Extended measuring range 0.05 S/cm... 500 ms/cm Process connections, materials, surface finish designed for use in hygienic applications
More informationBenchtop Water Quality Instruments Colour Touchscreen Meters
ph ORP Ion Conductivity Resistivity Total Dissolved Solids Salinity Benchtop Water Quality Instruments Colour Touchscreen Meters M A D E I N J A P A N www.horiba-laqua.com 2011 2012 2013 Benchtop Water
More informationTechnical Information Condumax CLS21D/CLS21
TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application
More informationIndumax CLS54D. Technical Information
Technical Information Indumax CLS54D Inductive conductivity sensor with hygienic design for applications in the food, beverage and pharmaceutical industries and in biotechnology Application The CLS54D
More informationTechnical Information Smartec CLD18
TI01080C/07/EN/01.12 71195835 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application The compact measuring
More informationJUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature
Data Sheet 20272 Page /7 JUMO ecotrans Lf 0 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature Type 20272 Housing for DIN rail mounting (5 x 7.5 mm to DIN EN
More informationMulti Water Quality Checker U-50 Series Instruction Manual CODE:GZ
Multi Water Quality Checker U-50 Series Instruction Manual CODE:GZ0000144342 Preface This manual describes the operation of the Multi Water Quality Checker, U-50 Series. Be sure to read this manual before
More informationNew Technology for Monitoring Cycle Chemistry. David M. Gray McIlvaine Hot Topic Hour February 21, 2013
New Technology for Monitoring Cycle Chemistry David M. Gray McIlvaine Hot Topic Hour February 21, 2013 Outline Sensor developments Measurement parameters - Conductivity - ph/orp - Dissolved oxygen - Sodium
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Protected Bulb Patented reference design for exceptional performance* Mounts in Signet standard fittings from
More informationCondumax CLS16 and CLS16D
Technical Information Condumax CLS16 and CLS16D Hygienic conductivity sensor, analog or digital with Memosens technology, cell constant k = 0.1 cm -1 Application Measurement in pure and ultrapure water:
More informationCondumax CLS21 and CLS21D
Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:
More informationMODEL 4081 Digital Conductivity Meter Operation Manual
MODEL 4081 Digital Conductivity Meter Operation Manual Model 4081 shown with Dip Cell, Lab Stand and Function Verifier Date: Serial No.: Dwg. No.: Calibration By: Printed in U.S.A. Rev. E 12/2007 TABLE
More informationWATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL
MicroChem Water Analysis System The MicroChem is a versatile multi-parameter instrument capable of being configured as a transmitter or PID controller. Specifically designed for drinking and wastewater
More informationMulti 197i. Operating manual. Portable ph / oxygen / conductivity measuring instrument. ba75339e03 01/2005 ON / OFF AUTO READ RUN / ENTER
perating manual N / FF M CAL AUT READ RUN / ENTER 7 92 1 7 6 ARng mg/l C REL1 TP RCL T Portable / oxygen / conductivity measuring instrument ba75339e03 01/2005 Accuracy when going to press The use of advanced
More informationMemosens CPS96D. Technical Information
Technical Information Memosens CPS96D Combination of ph and ORP electrode with Memosens technology With open aperture junction for very contaminated media and suspended solids Resistent to poisoning reference
More informationtesto 735, highly accurate alarm and logger thermometer with measurement site management
14 testo 735, highly accurate alarm and logger thermometer with measurement site management Wireless measurement with radio probes for air, iersion and penetration measurement Evaluate and document readings
More informationMore Meters and Accessories
More Meters and Accessories SevenGo Duo Portables High-end dual-channel portables combine various measurement parameters into one instrument: www.mt.com/ph InLab Sensors Quality sensors for every sample
More informationEndress Hauser. SmarTec M CLD 133 Conductivity Measurement
Technical Information / Operating Instructions TI 281C/07/en/08.02 No. 51506567 SmarTec M Conductivity Measurement Compact conductivity transmitter with inductive sensor and integrated temperature compensation
More informationSignet ph/orp Electrodes General Purpose
Signet 2724-2726 ph/orp Electrodes General Purpose Compatible with ALL Signet ph/orp instruments and SmartPro transmitters Features Patented reference design for exceptional performance and prolonged life
More informationUser Friendly Interface means: Power through Simplicity
W h a t i s t h e T & D T R - 5 i S e r User Friendly Interface means: Power through Simplicity The TR-5i Series is a family of data loggers designed to measure and record a variety of items: from temperature
More informationTARAline CS4. Data Sheet
TARAline CS4 indicator Application Chlorination agents Measuring system Electronic Information about the measuring range of sensors with 4-20 ma Accuracy after calibration at repeatability conditions (25
More informationTechnical Information Orbipac CPF81D/CPF82D and CPF81/CPF82
TI00191C/07/EN/1.1 717156 Products Solutions Services Technical Information Orbipac CPF81D/CPF8D and CPF81/CPF8 ph/orp compact electrodes, with digital Memosens technology or analog For processes in mining
More informationConductive conductivity measurement mypro CLM 431 / CLD 431 conductive
Technical Information TI 202C/07/en No. 51500563 Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive Two-wire transmitter for conductive measurement of conductivity and specific resistance
More informationSMARTPAT COND 1200 Technical Datasheet
SMARTPAT COND 1200 Technical Datasheet Digital conductive conductivity sensor for the water and wastewater industry 2-wire loop powered sensor with integrated transmitter technology Wide measuring range
More informationFPS. FPS Flexible Position Sensor. Function description. Your advantages and benefits
FPS www.comoso.com Accessories Sensor System FPS Flexible Position Sensor FPS Flexible Position Sensor The optional FPS sensor system measures the position of gripper jaws. It then indicates in which of
More information8900 Multi-Parameter Controller
F L O W + GF + XX DN XX X XX SE N S OR IN PU TS COM M PO RT / O U T O UT RE LA Y 2 RE LA Y 1 RE LA Y RE LA Y S I G N E T L o o p 1 L o o p 2 D a t a 6 1 2 7 8 9 N / C S I G N E T - 2 0 m A I n p u t -808-2
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type digital
More informationCondumax W CLS15 and CLS15D
Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationMJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400
Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in
More informationOPERATING MANUAL. ba77043e02 10/2015 LF 413T IDS LF 413T 3M IDS CONDUCTIVITY CELL
OPERATING MANUAL ba77043e02 10/2015 LF 413T IDS LF 413T 3M IDS CONDUCTIVITY CELL LF 413T IDS Copyright 2015, SI Analytics GmbH Reprinting - even as excerpts - is only allowed with the explicit written
More informationOPTISENS PH ph sensor. Technical Datasheet
Technical Datasheet ph sensor High quality and precise glass sensor for usage in water and waste water analysis Special sensor design for harsh applications Low maintenance costs and a long life cycle
More informationOPERATING MANUAL. ba15358e03 09/2014 F 500 DIN, F 500 BNC F 800 DIN, F 800 BNC FLUORIDE SENSITIVE ELECTRODE
OPERATING MANUAL ba15358e03 09/2014 F 500 DIN, F 500 BNC F 800 DIN, F 800 BNC FLUORIDE SENSITIVE ELECTRODE F 500 / F 800 Note The latest version of the present operating manual can be found on the Internet
More informationConductivity measurement SmarTec S CLD 132
Technical Information TI 207C/24/ae Conductivity measurement SmarTec S CLD 132 Transmitter for measurement of conductivity and concentration with inductive sensor Areas of application Alkali/acid concentration
More informationTemperature measuring instrument (3-channel)
Temperature measuring instrument (3-channel) testo 735 Highest accuracy thanks to system adjustment Highest precision over the entire measuring thanks to system adjustment C System accuracy up to 0.05
More informationPortable Multi-Channel Recorder Model DAS240-BAT
Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes
More informationWarranty conditions are available on this website: only in English version
THE MOST ACCURATE BATTERY POWERED SYSTEM FLOWIZ ( M L 2 5 2 ) C O N V E R T E R W I T H B A T T E R Y S U P P L Y Warranty conditions are available on this website: www.isomag.eu only in English version
More informationOPTISENS ORP 8590 Technical Datasheet
OPTISENS ORP 8590 Technical Datasheet ORP sensor for water and wastewaster industry Large ceramic diaphragm and integrated Pt100 Special sensor design for all-purpose applications Low maintenance costs
More informationAbsolute Encoders Multiturn
Absolute Encoders Multiturn Functional Safety, optical The absolute multiturn encoders Sendix 5863 SIL and 5883 SIL are perfectly suited for use in safety-related applications up to SIL3 according to DIN
More informationInductive conductivity transmitter JUMO CTI-Junior
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 03-7 25 Fax: +49 (0) 661 60 03-6 81 E-Mail: mail@jumo.net
More informationConductivity Transmitter N-LF V AC
OPERATING INSTRUCTIONS Conductivity Transmitter N-LF2000 230V AC These operating instructions apply to the following device: Article Measuring range Order number N-LF2000, Conductivity measuring device
More informationMelting Point Apparatus
Melting Point Apparatus Stuart has become the laboratory name in melting points. Offering solutions to determine high accuracy melting points. Stuart has a complete range of melting points, from manual
More informationSonoMeter 31 Energy Meters
SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption
More informationThermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Reference Guide
Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter Reference Guide Ross and the COIL trade dress are trademarks of Thermo Fisher Scientific, Inc. and its subsidiaries. AQUAfast,
More informationDIGITAL OXYGEN METER. Model : DO-5510
DIGITAL OXYGEN METER Model : DO-5510 ATTENTION : Fill the Probe's Electrolyte at first. Intend to keep the DO probe under the best condition, when user receive the DIGITAL OXYGEN METER along the PROBE,
More informationMHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data
Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical
More informationOPTISENS PH 8390 Technical Datasheet
OPTISENS PH 8390 Technical Datasheet ph sensor for water and wastewater industry Large PTFE diaphragm and integrated Pt100 Robust sensor design for harsh applications Low maintenance costs and a long life
More informationFluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease
Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality
More informationABB conductivity analyzer and probe package
Water Technologies & Solutions fact sheet ABB conductivity analyzer and probe package series AX430 single input analyzer with PID control description and use Advanced measuring capabilities Conductivity
More information