Mitigation Methods to Improve the Lightning Performance of Hybrid Transmission Line

Size: px
Start display at page:

Download "Mitigation Methods to Improve the Lightning Performance of Hybrid Transmission Line"

Transcription

1 Mitigation Methods to Improve the Lightning Performance of Hybrid Transmission Line Andrzej Mackow Mustafa Kizilcay Dept. of Electrical Eng. and Computer Science University Siegen Siegen, Germany Abstract EMTP simulations and lightning attachment models are performed to estimate backflashover performance of multicircuit transmission tower. Multi-circuit transmission tower has several systems on the tower and combines DC transmission over long distances with more flexible AC transmission. The outcome of simulations and calculations should give the range of backflashover withstand current and backflashover outage level. Maximum lightning current amplitude that does not cause backflashover across insulator string is estimated in response to first and subsequent strokes several flashover models. The paper presents a new unbalanced design of insulation. Latter should decrease backflashover rate for lines serving critical loads like HVDC lines. Index Terms-- backflashover, lightning stroke, multi-circuit transmission tower with AC and DC, modelling, flashover model I. INTRODUCTION Investigations in this paper have been done for two transmission lines that come into consideration of conversion to multi-circuit line with HVAC circuits and HVDC circuit (hereafter called hybrid line). Conversion to HVDC is most effective way to increase transmission capacity of existing AC lines [1]. The multi-circuit line with AC and DC systems offers diversified solutions for future transmission lines [1]- [3]. HVDC system could be accompanied by HVAC systems at various transmission voltage levels (e.g. 380 kv, 220 kv or 110-kV). The 380-kV circuit is substituted by a HVDC circuit on a tower. Some guidelines related to adaption of existing AC conductors and AC insulators are summarized in [1]. Available conductors of 380-kV circuit can be adapted to transfer DC power. Existing AC insulators has to be replaced by insulators intended for DC voltage. Composite longrod insulators are preferable choice due to adequate pollution performance. The outages that are caused by lightning strokes have two origins. One of them is backflashover. Lightning strokes that are intercepted by shield wires can afterwards cause backflashover across insulator strings. Lightning incidence (number of strokes to shield wire) is the first step to determine lightning performance of the transmission line. Estimation of equivalent interception radius reduces this task and is sufficient to determine lightning incidence of the line. Furthermore based on lightning incidence of hybrid line number of backflashovers can be estimated with aid of EMTP simulations. A backflashover analysis of hybrid line by means of electromagnetic simulations is presented in this work. This study was focused how new installed HVDC system affects lightning performance of multi-circuit towers. Backflashover withstand current and backflashover outage rate are calculated. Simulations in EMTP-ATP [4] consider effects like: footing resistance, number of phases and power frequency voltage, coupling from lightning current that flows through shielding wire, dependencies of lightning current parameters. Flashover across insulator string was implemented using MODELS [5]. II. BACKFLASHOVER OUTAGE RATE Lightning can cause flashover in two different manners. Either lightning strikes conductor directly and flashover occurs (shielding failure) or lightning flash terminates on tower or shield wire and causes a backflashover. The Backflashover Rate (BFR) indicates number of lightning strokes to shield wire that result in backflashover. BFR = 0.6 N f ( I) di (1) s IC where: N S is lightning incidence (backflashover /100 km/year), f(i) is the probability density function of the lightning crest distribution according to [6], I C is critical current (ka) (backflashover withstand current). The factor 0.6 is used in (1) to consider the effect the strokes within the span [6]. The BFR S is rate of subsequent strokes to shield wire causing backflashover can be expressed as BFR = 0.6 N P f ( I) di (2) S s S IC This work was supported by German TSO, Amprion.

2 where P S is the probability of backflashover from subsequent stroke (assumed that previous strokes has not caused backflashover). P S can be estimated by assuming no correlation between first and subsequent return-stroke currents, as I n 1 CS PS = P n 1 fs ( I) di (3) 2 0 where I cs (ka) is the critical current associated with subsequent strokes, P n is the probability that there are n strokes per flash, as given in [7]. That statistical distribution of number of strokes pro flash in [7] has been reviewed as overestimated in [8]. Moreover not all subsequent strokes strike the overhead line because new terminations channels may develop. Thus subsequent stroke may terminate hundred meters from transmission line [8]. f s (I) is the probability density function of the lightning crest current distribution for subsequent strokes according to [9]. The total backflashover rate, BFR T (backflashover/100 km/yr), that is the rate of lightning first and subsequent strokes to phase conductors causing backflashover, is given as BFR = BFR + BFR (4) III. T LIGHTNING INCIDENCE A. Lightning Incidence Lightning incidence is the first step to determine lightning performance of the transmission line. Estimation of equivalent interception radius reduces this task and is sufficient to determine lightning incidence of the line [10]. The basis formula of equivalent interception radius is (5). R S E eq = r h (5) where r and E are factors listed in Tab. II and h is height of conductor (m). After equivalent interception radius was calculated, the annual number of lightning strikes to shields wires per 100 km of a transmission line N s can be estimated with (6). Ns = 0.1 Ng(2 Req + b) (6) where N g is ground flash density ( strikes/km 2 /year), and R eq is the equivalent interception radius of shield wire (in meters), b is separation distance between shield wires (in meters). The average height of the shield wire in calculations is assumed as its height at the tower minus 2/3 of the sag [11]. Different models with various coefficients were proposed to estimate equivalent interception radius (Table II). IV. SIMULATION MODEL Multi-circuit towers have a height up to 60 m and have up to three conductors at each cross arm. EMTP-ATP simulations have been performed for two tower configurations (s. Fig. 1) coming into consideration for a multi-circuit line with AC/DC circuits. - + N GW W 380-kV AC W V U W V U 110-kV AC 110-kV AC TOWER A V U 2 x 380-kV AC V W W U V GW TOWER B N kV DC Figure 1. Layout of hybrid transmission towers A und B The upper two cross-arms of tower A carry on left side a 420-kV HVDC and on right side a 380-kV HVAC system. A 110-kV double circuit line is suspended from the lowest cross arm. The upper two cross-arms of tower B on the right side carry 420-kV HVDC. Tower B is 6.5 m higher than tower A. Single line diagram of simulation model in ATP Draw is presented in Fig. 2. The modelling method for the backflashover analysis used in this paper is based mainly upon [12]. All simulations were computed for section with 9 towers. The lightning stroke is applied to tower 5 that is located in the middle of investigated section. Footing impedance for all towers is 10 Ω according to [12] as typical value for EHV lines. All towers in investigated sections were assumed to have the same height. (7-km) (330m) (330m) (7-km) 420-kV DC 380-kV AC 2 x 110-kV AC shield wire FLASHOVER MODEL I(t) Zf=1000Ω Shield wire 2 x 110-kV AC 380-kV AC 420-kV DC Rf Rf Rf TOWER 1 TOWER 5 Figure 2. Single line diagram of simulation model in EMTP-ATP. LIGHTNIN G SOURCE TOWER 9

3 A. Tower Model Multistory model [13] is used to represent transmission towers. In multistory model each vertical tower section between cross arms is represented by lossless line connected in series with RL parallel circuit. This parallel circuit represents attenuation of traveling waves. Model and equations for all impedances were described in [13]. In Fig. 3 multistory model is shown. Formula for surge impedance is given as 1 R Zwaist = 60ln cot 0.5 tan (7) h where rh 1 2+ rh 2 + rh 3 1 R = (8) h h = h 1 + h 2 (9) R1 R2 R3 R4 ZT1,h1,vt ZL1 ZT2,h2,vt ZL2 ZT3,h3,vt ZL3 ZT4,h4,vt ZL4 Figure 3. Tower model with additional RL-circuits. For the tower A with 50 m and tower B with 56.5 m equation (1) delivers the surge impedance Z waist_a = 204 Ω and Z waist_b = 208 Ω, respectively. B. Transmission Lines Total 9 towers are represented including all line circuits the model [2] at f = 400 khz. Span lengths have m. The investigated section with 9 towers is terminated at both ends with 7 km long additional (constant parameters distributed line) model that has the same electrical parameters as spans between investigated towers 1-9. These additional sections should prevent impact of reflected waves. The investigated section is connected to voltage sources (via additional line section) in order to take into account the effect on the AC and DC steady-state voltage of the lines on a lightning surge. C. Flashover Models Electromagnetic transients programs allow investigating flashover phenomena in more detailed way. Various flashover models are based on diverse assumptions and have been developed based on different experimental tests. In this study several flashover models are applied for comparison purposes. First model is related to flashover voltage-time characteristic of insulators. A more sophisticated way to represent flashover is achieved by representing the physical process of flashover. Several flashover models have been developed in order to represent the flashover progression process across insulator gaps directly. These models are called Leader Progression Models (LPM). Models 2-6 are various implementation of leader progression model. 1) Disruptive criterion according to Kind [14] 2) LPM according to Pigini [15] 3) LPM according to Motoyama 1996 [16] 4) LPM according to Motoyama 1998 [17] 5) LPM according to CIGRE Working Group [6] 6) LPM according to Wang [18] They were implemented using MODELS [5]. Parameters and flashover criteria are precisely described in [6] and [14]-[18]. Insulation levels are correspondingly adapted for all systems. All insulators are composite insulator strings with longrod design. Gap length D of composite insulator strings for 110-kV is ca mm, 380-kV AC and HVDC is ca mm. Each flashover model connected across insulator strings controls switch. After fulfillment of breakdown condition, surge current flows into failure conductor. The definition of the lightning strength of insulators is based on tests with standard lightning (SI) impulse waveforms (1.2/50 µs). In reality wave shapes of lightning surge voltages across insulators differ from standard lightning wave shapes [18]. The waveform of lightning surge voltage across insulators differs from standard lightning impulse due to reflections from adjacent towers and footing impedance. Testing of insulation under all possible lightning overvoltages would be very time consuming and is therefore not economical. Some models were developed to consider short tail lightning impulse lightning voltage (STLI) (1.45/11 µs) [16], [18]. As pointed in [1] constant DC voltage may be higher than the instantaneous voltage on any of the AC phase conductors on hybrid tower. Thus the composite overvoltage across insulator string of DC may be higher than across insulator of AC circuit. The DC insulator dimensioning and selection are based on the pollution performance, the flashover performance level and the environmental stress [1]. Proper classification of candidate insulators require flashover pre-calculations considering breakdown characteristics with different surge polarities. Due to air clearances restrictions from original HVAC multi-circuit tower new HVDC insulator strings have the same length as 380-kV insulator strings.

4 D. Ligthning Source The lightning stroke is modelled by a current source and a parallel resistance, which represents the lightning path surge impedance. Lightning surge impedance is selected as 1000 Ω according to [12]. TABLE I. LIGHTNING CURRENT PARAMETERS [8] Parameter First stroke Subsequent stroke Peak current I I, initial 27.7 ka 11.8 ka Maximum steepness S m 23.3 ka/µs 39.9 ka/µs Front time t d30/ µs 0.67 µs Tail time to half value t h 77.5 µs 30.2 µs Fig. 4 shows the representation of first and subsequent stroke current waveforms with CIGRE lightning waveform [8], considering the median values according to Berger s conditional distributions [9] for subsequent strokes and global distribution according to [6] for first strokes. investigate overhead lines (OHL). In latter r and E coefficients were validated with field observation data from [21] as well as recently observed lightning incidence for high transmission towers [22]. Methods with smallest deviations were used in this study and are based on EGM by Armstrong and generic models according to Rizk and Petrov. Results by means of EGM by Armstrong are employed in this study. TABLE II. EQUIVALENT INTERCEPTION RADIUS AND LIGHTNING INCIDENCE Author Req Tower A Tower B ELECTROGEOMETRIC MODELS strokes to shield wires in year over 100 km OHL Young [23] 14.3 h Love [24] 13.9 h Armstrong, Whitehead [25] 33.7 h Brown, Whitehead [26] 30.1 h Wagner, Hileman [27] 11.0 h Whitehead [28] 14.2 h GENERIC MODELS Rizk [29] 18.9 h Petrov [30] 6.2(h+15) Ait-Amar & Berger [31] 33.0 h Figure 4. Lightning currents with median values. According to [8] the front time t f and steepness S m depend on the peak value of the lightning current for first stroke. For subsequent stroke the front time t f is constant, whereas S m depends on the peak value of the lightning current. In this paper was used simplified representation of first stroke. Features like: initial concavity, subsequent abrupt rise and several peaks were neglected. Representation of first and subsequent stroke has only one peak and smooth shape. B. Backflashover Simulations EMTP-ATP simulations were performed to compare the behavior of insulators in response to lightning surge voltage impulses. Some researchers pointed out that waveforms of lightning voltages across insulator strings are closer to STLI than LI [18], [32]. Therefore flashover model 3 and 6 are based on experiments with STLI. Flashover models were embedded in simulation model from Fig. 2. Fig. 5 presents lightning surge voltages across insulator string that result in backflashover. V. LIGHTNING CALCULATIONS A. Lightning Incidence Lightning incidence is calculated with various values of coefficients for R eq and results are shown in Table II. N g is based on [19] and amounts to 4.2 strikes/km 2 /year. Results are similar among all interception models and are higher for higher tower B. Lightning incidence based on generic models is higher than results based on electrogeometric model (EGM). According to comparison of lightning incidence factors r and E from [20] some of them were graded to Figure 5. Lightning surge voltages across insulator string of HVDC plus pole. (1)-Kind, (2)-Pigini, (3) - Motoyama 1996, (4)- Motoyama 1998, (5)- CIGRE, (6)-Wang These waveforms are from first negative lightning stroke to shield wire on the tower top. Since voltage of plus pole is constant (+420kV), time instant of lightning stroke is not

5 relevant. Backflashover withstand currents are shown in Fig. 6, simulated for all flashover models (1-6). These backflashover withstand currents vary considerably among the flashover models. The difference between highest and lowest current is up to 170 %. Higher critical currents were obtained for LPM. In particular LPM based on STLI experiments result in critical current over 200 ka. Further computed backflashover critical currents for towers A and B are simulated by means of LPM according to CIGRE WG [6]. That flashover models enables to consider design of insulator string (longrod or cap-and-pin) and polarity of impulse voltage. backflashover occur across two insulators of 110-kV circuit (power frequency voltage is equal on affected conductors) for 72 ka first negative stroke. That crest value of lightning stroke exceeds backflashover withstand current of both 110- kv circuit and causes backflashover in each 110-kV circuit. Voltage waveform across insulator at positive conductor (1) of HVDC sags shortly after first backflashover around 12 µs across 110-kV insulator. Figure 7. Overvoltages across the upper insulator string of positive pole (1), return pole (2) and two 110-kV phases (3), (4) in response to first stroke on tower top (72 ka). Figure 6. Critical backflashover current causing bachflashover across insulator string of HVDC plus pole Considerable deviations due to flashover modelling were also found for flashover models (1-3) in simulations of the critical current causing backflashover in a 110 kv circuit of a multi-circuit line [33]. Moreover minimum shielding failure flashover current for first and subsequent lightning strokes to conductor depend strongly on flashover model as demonstrated in [34]. C. Backflashover Outage Rate of Tower A The power frequency voltage is considered by calculating the backflashover withstand current I C (refer to (1)) for instantaneous power frequency voltages estimated for each of twelve 30 steps of phase angle. Thus sinusoidal waveform of 110-kV and 380-kV AC voltages is considered. Flashover occurs firstly on the lowest cross arm almost simultaneously across two 110-kV voltage insulators. In fact, higher voltage difference across insulator is to be expected for the positive conductor (plus pole) of the HVDC system as pointed in [1]. 110-kV insulators are three times shorter. This is crucial for higher susceptibility to backflashover of 110-kV systems. The value of backflashover withstand currents of 110-kV insulators vary from 68 to 77 ka depending on time instant of lightning stroke. Twelve estimated critical currents resulting from different power frequency instantaneous voltages are inserted in (1) as lower integration limit. Overvoltages across two insulator strings of 110-kV (of different circuits, both phases in voltage maximum) and across insulator of plus pole (upper cross-arm) and return pole (middle cross-arm) are presented in Fig. 7. Two Influence of backflashovers is more visible for higher lightning stroke current. In Fig. 8 the same overvoltages are presented in response to 150-kA first negative stroke. Two simultaneous backflashover occur across two insulators of 110-kV circuit around 11 µs (power frequency voltage is equal on affected conductors). In voltage waveform across plus pole insulator (1) on the upper cross-arm and return pole insulator (2) on the middle cross-arm considerable voltage sag is visible due to previous backflashovers across 110-kV insulator strings. That voltage sag hinders efficiently rise of surge voltage across insulators and avoids subsequent backflashovers across other insulator strings respectively. Figure 8. Overvoltages across the upper insulator string of positive pole (1), return pole (2) and two 110-kV phases (3), (4) in response to first stroke on tower top (150 ka). After backflashover other 110-kV sound phases were disconnected (3-phase auto reclosing). Amplitude of the lightning current was further increased up to 200 ka with corresponding front time t f and steepness S m according to [8].

6 Subsequent flashovers across sound conductors of 380-kV circuit and of HVDC circuit do not occur after backflashover across 110-kV insulators. Whereas backflashover from subsequent strokes are unlikely to occur across HVDC insulators, they can occur across 110-kV insulators. Subsequent strokes higher than 42 ka (average backflashover withstand current) may result in backflashover across insulator strings of 110-kV circuit. Converting of tower A into AC/DC multicircuit tower has not changed lightning backflashover performance of the line. Results of backflashover simulations show that lightning strokes first of all affect 110-kV circuits. First lightning strokes as well as subsequent strokes may cause backflashover across insulators on the lowest cross arm. The backflashover withstand level of the HVDC system is much higher and influenced strongly by the lightning performance of 110-kV systems. BFR T for tower A has not changed due to conversion in hybrid line and amounts to 5.08 backflashover/100km/yr. The BFR T consists of backflashover caused by first strokes as well as by subsequent strokes. D. Backflashover Outage Rate of Tower B Tower B from Fig. 1 has been chosen for comparison of backflashover behavior of 420-kV HVDC and 380-kV HVAC systems. The new HVDC composite insulators have the same length as 380-kV composite insulators. The minimal lightning current that causes backflashover has been determined for 380-kV AC and HVDC systems. The overvoltages across several insulators are presented in Fig. 9 in response to first stroke on tower top (150 ka). That value is backflashover withstand current for insulator string of plus pole. The backflashover across insulator string of positive pole occurs firstly. Higher positive voltage of 420-kV HVDC positive pole causes higher surge voltage across the insulator for a lightning stroke of negative polarity. This assumption is valid as long as both systems have composite insulators of equal length. occur after first backflashover across insulator string of plus pole. To what extent has conversion of 380-kV circuit into HVDC-circuit changed BFR, is investigated with original configuration of tower B (three 380-kV circuits). The power frequency voltage is considered by calculating the backflashover withstand current I C (refer to (1)) for instantaneous power frequency voltages estimated for each of twelve 30 steps of phase angle. Thus sinusoidal waveform of 380-kV AC voltage is considered. Only one backflashover occurs up to 200 ka. Backflashover withstand current and backflashover locations are variable and depend on power frequency voltage in 380-kV circuits and distance to tower top. Average backflashover withstand current is 171 ka. Subsequent strokes to tower top are hazardous neither for 380-kV insulators nor for HVDC insulators. The total BFR has risen from 0.18 to 0.34 backflashover/100km/yr due to conversion into hybrid line. Conversion of towers with 380- kv double circuit into hybrid line increases the probability of occurrence of backflashover. Constant +420-kV voltage of plus pole makes upper insulator at plus pole more prone to backflashover in comparison with the original 380-kV circuit. An unbalanced insulation design to prevent the backflashover across insulator string of HVDC system that serves critical loads can be realized in two manners: Whereas original 380-kV conductors are unchanged, substitution of AC insulators may be considered. Porcelain longrod insulators are more prone to flashovers than composite longrod insulators. Substitution of composite insulator for porcelain insulators could change backflashover behavior on the tower. CIGRE flashover model considers only insulator design (longrod). Additional test of dielectric strength of longrod porcelain insulator strings are required to revise this issue. This approach would necessitate substitution of all insulator strings. Another way is to increase critical backflashover current in case of a HVDC insulator. This solution is also more economical because only HVDC insulator has to be replaced due to conversion. Elongation of composite insulator of HVDC to 3600 mm would result in backflashover across 380-kV insulator string. Figure 9. Overvoltages across the upper insulator string of positive pole (1), return polse (2) and two 3800-kV phases (3),(4) in response to first stroke on tower top (150 ka). Amplitude of the lightning current was further increased up to 200 ka with corresponding front time t f and steepness S m according to [8]. Subsequent flashovers across sound conductors of 380-kV circuit and of HVDC circuit do not VI. CONCLUSIONS The EMTP-ATP simulations have been performed for two tower configurations coming into consideration for a multicircuit line with AC/DC circuits. Furthermore subsequent lightning strokes were also considered in this investigation. Conversion of tower A with 380-kV and 110-kV doublecircuit on the same tower into AC/DC multi-circuit line does not increase lightning backflashover performance of the line. First lightning strokes as well as subsequent strokes cause first backflashover across 110-kV insulators on the lowest cross arm. The backflashover withstand level of the HVDC

7 system is much higher and influenced strongly by the lightning performance of 110-kV systems. Conversion of tower B with 380-kV circuits into AC/DC multi-circuit line increases the probability of occurrence of backflashover. Constant +420-kV voltage of plus pole makes upper insulator at plus pole more prone to backflashover in comparison with the original 380-kV circuit. Conversion of an AC system into bipolar DC system increases outage rate for the converted circuit. Subsequent strokes are not critical for the operation of HVDC and 380-kV systems. An unbalanced insulation design to protect the HVDC system that serves critical loads can be realized in two manners. The backflashover performance is estimated by means of several flashover models. They perform differently depending on the lightning waveform and investigated tower. Flashover model can influence strongly lighting outage rates of OHL. Additional test of dielectric strength of insulator strings and field observations are required to revise existing flashover models. This issue concerns particularly some of Leader Progression Models (LPM), since they are partially based on air gap breakdown of rod-rod field tests. ACKNOWLEDGMENT The authors like to thank Amprion for their expert advices. REFERENCES [1] CIGRE WG B 2.41, Guide to the conversion of existing AC lines to DC operation, 2014 [2] J. Lundkvist, I. Gutman and L. Weimers, "Feasibility study for converting 380 kv AC lines to hybrid AC/DC lines, in Proc. of 2009 EPRI's High Voltage Direct Current & Flexible AC Transmission Systems Conference. [3] C. Neumann, B. Rusek, S. Steevens and K.-H. Weck, Design and layot of AC-Dc hybrid lines, in Proc. of 2013 CIGRE Symposium, Auckland, Neuseeland, [4] Canadian/American EMTP User Group, ATP Rule Book, revised and distributed by EEUG Association, [5] L. Dube, Users guide to MODELS in ATP, 1996 [6] CIGRE WG 01 SC 33, Guide to procedures for estimating the lightning performance of transmission lines, 1991 [7] Lightning and Insulator Subcommittee of the T&D Committee, "Parameters of lightning strokes. A review", IEEE Trans. Power Delivery, vol. 20(1), pp , [8] CIGRE WG C4.407, Lightning Parameters for Engineering Applications, [9] K. Berger, R. B. Anderson, H. Kroninger, "Parameters of the Lightning Strokes," ELECTRA, vol. 41, pp , July [10] IEEE WG, "Estimating lightning performance of transmission lines II- Updates to analytical models," IEEE Trans. Power Delivery, vol. 8, pp , Jul [11] A. J. Eriksson, "An improved electrogeometric model for transmission line shielding analysis," IEEE Trans. Power Delivery, vol. PWRD-2, pp , Dec [12] A. Ametani und T. Kawamura, "A method of a lightning surge analysis recommended in Japan," IEEE Trans. Power Delivery, vol. 20, pp , [13] M. Ishi, T. Kawamura, T. Kouno, T. Ohsaki, E. Shiokawa and K. Murotani, Multistory transmission tower model for lightning surge analysis, IEEE Transactions on Power Delivery, pp , [14] Kind, The volt-time area in the case of impulse stressing of technical electrode arrangements in air( orginal title in German: Die Aufbauflächse bei Stoßspannungsbeanspruchung technischer Elektrodenanordungen in Luft, ETZ-A, pp , [15] A. Pigini, G. Rizzi, E. Garbagnati, A. Porrino and G. Pesavento, Performance of large air gaps under lightning overvoltages: Experimental study and analysis of accuracy of predetermination methods, IEEE Transations on Power Delivery, pp , Apr [16] H. Motoyama, Experimental Study and Analysis of Breakdown Characteristics of Long Air Gaps with Short Tail Lightning Impulse, IEEE Transactions on Power Delivery, pp , Apr [17] H. Motoyama, K. Shinjo, Y. Matsumoto, N. Itamoto, Observation and analysis of multiphase back flashover on the Okushishiku Test Transmission Line caused by winter lightning, IEEE Transactions on Power Delivery, vol. 13 pp , Apr [18] X. Wang, Z. Yu und J. He, Breakdown Process Experiments of 110- to 500-kV Insulator Strings Under Short Tail Lightning Impulse, IEEE Transactions on Power Delivery, pp , Oct [19] BLIDS: Flash Information Service by SIEMENS, x, [online]. [20] P. N. Mikropoulos and T. E. Tsovilis, Estimation of lightning incidence to overhead transmission lines, IEEE Transactions on Power Delivery, vol. 25 pp , July [21] A. J. Eriksson, "The incidence of lightning strikes to power lines," IEEE Trans. Power Delivery, vol. PWRD-2, pp , Jul [22] J. Takami and S. Okabe, Observational results of lightning current on transmission towers, IEEE Transaction on Power Delivery, pp , [23] F. S. Young, J. M. Clayton und A. R. Hileman, Shielding of Transmission Lines, IEEE Trans. on P A&S, pp , [24] E. R. Love, Improvements in lightning stroke modeling and applications to design of EHV and UHV transmission lines, M.Sc. dissertation, Univ. Colorado, 1973 [25] H. R. Armstrong und E. R. Whitehead, Field and Analytical Studies of Transmission Line Shielding, IEEE Trans. on P. A&S, pp , Januar [26] G. W. Brown und E. R. Whitehead, Field and Analytical Studies of Transmission Line Shielding, IEEE Trans. on p A&S, pp , [27] C. F. Wagner, The Relation Between Stroke Current and the Velocity of the Return Stroke, IEEE Trans. on PA & S, pp , Oktober [28] E. R. Whitehead, CIGRe survey of the lightning performance of EHV transmission lines, ELECTRA, vol. 33. pp , [29] F. A. Rizk, Modelling of transmission line exposure to direct lightning strokes to overheadlines, IEEE Trans. Power Del., pp , [30] N. I. Petrov, G. Petrova und R. T. Waters, Determination of attractive area and collection volume of earthed structures, in Proc. of 25th ICLP, Rhodes, Griechenland, [31] S. Ait-Amar und G. Berger, A modified version of the rolling sphere method, IEEE Trans. Dielectr. Electr. Insul., pp , Jul [32] A. Ancajima, A. Carrus, E. Cinieri und C. Mazzetti, Behavior of MV Insulators Under Lightning-Induced Overvoltages: Experimental Results and Reproduction of Volt-Time Characteristics by Disruptive Effect Models, IEEE Transactions on Power Delivery, pp , January 2010 [33] M. Kizilcay und C. Neumann, Backflashover analysis for 110-kV lines at multi-circuit overhead transmission line towers, in Proc. o IPST, Kyoto, Japan, 2009 [34] J Datsios, P. N. Mikropoulos and T. Tsovilis, " Estimation of the minimum shieldinh failure flashover current for first and subseqeunt lightning strokes to overhead transmission lines," Electric Power System Research, pp , 2014.

Estimating the Lightning Performance of a Multi- Circuit Transmission Tower

Estimating the Lightning Performance of a Multi- Circuit Transmission Tower Estimating the Lightning Performance of a Multi Circuit Transmission Tower Pawel Malicki, Andrzej Mackow and Mustafa Kizilcay University of Siegen Chair of Electrical Power Systems Siegen, Germany pawel.malicki@unisiegen.de

More information

Mitigation of Back-Flashovers for 110-kV Lines at Multi-Circuit Overhead Line Towers

Mitigation of Back-Flashovers for 110-kV Lines at Multi-Circuit Overhead Line Towers Mitigation of Back-Flashovers for -kv Lines at Multi-Circuit Overhead Line Towers Mustafa Kizilcay Abstract--An increase of back-flashovers in a -kv system has been observed along an overhead line route

More information

Parameters Affecting the Back Flashover across the Overhead Transmission Line Insulator Caused by Lightning

Parameters Affecting the Back Flashover across the Overhead Transmission Line Insulator Caused by Lightning Proceedings of the 14 th International Middle East Power Systems Conference (MEPCON 10), Cairo University, Egypt, December 19-21, 2010, Paper ID 111. Parameters Affecting the Back Flashover across the

More information

Analysis of lightning performance of 132KV transmission line by application of surge arresters

Analysis of lightning performance of 132KV transmission line by application of surge arresters Analysis of lightning performance of 132KV transmission line by application of surge arresters S. Mohajer yami *, A. Shayegani akmal, A.Mohseni, A.Majzoobi High Voltage Institute,Tehran University,Iran

More information

PREVENTING FLASHOVER NEAR A SUBSTATION BY INSTALLING LINE SURGE ARRESTERS

PREVENTING FLASHOVER NEAR A SUBSTATION BY INSTALLING LINE SURGE ARRESTERS 29 th International Conference on Lightning Protection 23 rd 26 th June 2008 Uppsala, Sweden PREVENTING FLASHOVER NEAR A SUBSTATION BY INSTALLING LINE SURGE ARRESTERS Ivo Uglešić Viktor Milardić Božidar

More information

Lightning performance of a HV/MV substation

Lightning performance of a HV/MV substation Lightning performance of a HV/MV substation MAHMUD TAINBA, LAMBOS EKONOMOU Department of Electrical and Electronic Engineering City University London Northampton Square, London EC1V HB United Kingdom emails:

More information

2000 Mathematics Subject Classification: 68Uxx/Subject Classification for Computer Science. 281, 242.2

2000 Mathematics Subject Classification: 68Uxx/Subject Classification for Computer Science. 281, 242.2 ACTA UNIVERSITATIS APULENSIS Special Issue SIMULATION OF LIGHTNING OVERVOLTAGES WITH ATP-EMTP AND PSCAD/EMTDC Violeta Chiş, Cristina Băla and Mihaela-Daciana Crăciun Abstract. Currently, several offline

More information

Simulation of Lightning Transients on 110 kv overhead-cable transmission line using ATP-EMTP

Simulation of Lightning Transients on 110 kv overhead-cable transmission line using ATP-EMTP Simulation of Lightning Transients on 110 kv overhead-cable transmission line using ATP-EMTP Kresimir Fekete 1, Srete Nikolovski 2, Goran Knezević 3, Marinko Stojkov 4, Zoran Kovač 5 # Power System Department,

More information

Lightning Flashover Rate of an Overhead Transmission Line Protected by Surge Arresters

Lightning Flashover Rate of an Overhead Transmission Line Protected by Surge Arresters IEEE PES General Meeting June 23-27, 27, 2007, Tampa Lightning Flashover Rate of an Overhead Transmission Line Protected by Surge Arresters Juan A. Martinez Univ. Politècnica Catalunya Barcelona, Spain

More information

Accuracy of Lightning Surge Analysis of Tower Surge Response

Accuracy of Lightning Surge Analysis of Tower Surge Response Accuracy of ightning Surge Analysis of Tower Surge esponse Naoki Itamoto, Hironao Kawamura, Kazuo Shinjo, Hideki Motoyama, Masaru Ishii Abstract--This paper presents a comparison between the measured and

More information

Simplified Approach to Calculate the Back Flashover Voltage of Shielded H.V. Transmission Line Towers

Simplified Approach to Calculate the Back Flashover Voltage of Shielded H.V. Transmission Line Towers Proceedings of the 14 th International Middle East Power Systems Conference (MEPCON 1), Cairo University, Egypt, December 19-1, 1, Paper ID 1. Simplified Approach to Calculate the Back Flashover Voltage

More information

The line-lightning performance and mitigation studies of shielded steelstructure

The line-lightning performance and mitigation studies of shielded steelstructure The line-lightning performance and mitigation studies of shielded steelstructure distribution lines ASNAWI MOHD BUSRAH, MALIK MOHAMAD Energy System Group TNB Research Sdn Bhd No 1, Lorong Ayer Hitam, 43000

More information

Estimating BFOR on HV Transmission Lines Using EMTP and Curve of Limiting Parameters

Estimating BFOR on HV Transmission Lines Using EMTP and Curve of Limiting Parameters Estimating BFOR on HV Transmission Lines Using EMTP and Curve of Limiting Parameters Petar Sarajcev, Josip Vasilj, Patrik Sereci Abstract--This paper presents a method for estimating the backflashover

More information

Maximum Lightning Overvoltage along a Cable due to Shielding Failure

Maximum Lightning Overvoltage along a Cable due to Shielding Failure Maximum Lightning Overvoltage along a Cable due to Shielding Failure Thor Henriksen Abstract--This paper analyzes the maximum lightning overvoltage due to shielding failure along a cable inserted in an

More information

Lightning Performance Improvement of 115 kv and 24 kv Circuits by External Ground in MEA s Distribution System

Lightning Performance Improvement of 115 kv and 24 kv Circuits by External Ground in MEA s Distribution System Lightning Performance Improvement of 115 kv and 24 kv Circuits by External Ground in MEA s Distribution System A. Phayomhom and S. Sirisumrannukul Abstract This paper presents the guidelines for preparing

More information

Study of Tower Grounding Resistance Effected Back Flashover to 500 kv Transmission Line in Thailand by using ATP/EMTP

Study of Tower Grounding Resistance Effected Back Flashover to 500 kv Transmission Line in Thailand by using ATP/EMTP Study of Tower Grounding Resistance Effected Back Flashover to 500 kv Transmission Line in Thailand by using ATP/EMTP B. Marungsri, S. Boonpoke, A. Rawangpai, A. Oonsivilai, and C. Kritayakornupong Abstract

More information

ABSTRACTS of SESSION 6

ABSTRACTS of SESSION 6 ABSTRACTS of SESSION 6 Paper n 1 Lightning protection of overhead 35 kv lines by antenna-module long flashover arresters Abstract: A long-flashover arrester (LFA) of a new antenna-module type is suggested

More information

Software Development for Direct Lightning Stroke Shielding of Substations

Software Development for Direct Lightning Stroke Shielding of Substations Software Development for Direct Lightning Stroke Shielding of Substations P. N. Mikropoulos *, Th. E. Tsovilis, P. Chatzidimitriou and P. Vasilaras Aristotle University of Thessaloniki, High Voltage Laboratory,

More information

Lightning overvoltage and protection of power substations

Lightning overvoltage and protection of power substations Lightning overvoltage and protection of power substations Mahmud Trainba 1, Christos A. Christodoulou 2, Vasiliki Vita 1,2, Lambros Ekonomou 1,2 1 Department of Electrical and Electronic Engineering, City,

More information

Computation of Lightning Impulse Backflashover Outages Rates on High Voltage Transmission Lines

Computation of Lightning Impulse Backflashover Outages Rates on High Voltage Transmission Lines www.ijape.org International Journal of Automation and Power Engineering (IJAPE) Volume Issue, January DOI:./ijape... omputation of Lightning Impulse Backflashover Outages Rates on High Voltage Transmission

More information

INSTALLATION OF LSA ON A 400 KV DOUBLE-CIRCUIT LINE IN RUSSIA

INSTALLATION OF LSA ON A 400 KV DOUBLE-CIRCUIT LINE IN RUSSIA Application of Line Surge Arresters in Power Distribution and Transmission Systems COLLOQUIUM Cavtat 2008 INSTALLATION OF LSA ON A 400 KV DOUBLE-CIRCUIT LINE IN RUSSIA L. STENSTRÖM 1), J. TAYLOR, N.T.

More information

Statistical Lightning Simulations for a HV "Mixed" Overhead-Cable Line: Preliminary Studies

Statistical Lightning Simulations for a HV Mixed Overhead-Cable Line: Preliminary Studies 2014 International Conference on Lightning Protection (ICLP), Shanghai, China Statistical Lightning Simulations for a HV "Mixed" Overhead-Cable Line: Preliminary Studies F. M. Gatta, A. Geri, S. Lauria

More information

TRIGGERED by energy transition towards sustainability,

TRIGGERED by energy transition towards sustainability, Lightning Overvoltages in a HVDC Transmission System comprising Mixed Overhead-Cable Lines M. Goertz, S. Wenig, S. Gorges, M. Kahl, S. Beckler, J. Christian, M. Suriyah, T. Leibfried Abstract This paper

More information

Effective Elimination Factors to the Generated Lightning Flashover in High Voltage Transmission Network

Effective Elimination Factors to the Generated Lightning Flashover in High Voltage Transmission Network International Journal on Electrical Engineering and Informatics - Volume 9, Number, September 7 Effective Elimination Factors to the Generated Lightning Flashover in High Voltage Transmission Network Abdelrahman

More information

Analyzing and Modeling the Lightning Transient Effects of 400 KV Single Circuit Transmission Lines

Analyzing and Modeling the Lightning Transient Effects of 400 KV Single Circuit Transmission Lines International Journal of Science and Engineering Investigations vol. 2, issue 19, August 2013 ISSN: 2251-8843 Analyzing and Modeling the Lightning Transient Effects of 400 KV Single Circuit Transmission

More information

Modeling insulation in high-voltage substations

Modeling insulation in high-voltage substations 38 ABB REVIEW DESIGNED FOR SAFETY DESIGNED FOR SAFETY Modeling insulation in high-voltage substations The goal of insulation coordination is to determine the dielectric strength of transformers and other

More information

B2-301 IMPROVING DOUBLE CIRCUIT TRANSMISSION LINE RELIABILITY THROUGH LIGHTNING DESIGN

B2-301 IMPROVING DOUBLE CIRCUIT TRANSMISSION LINE RELIABILITY THROUGH LIGHTNING DESIGN 21, rue d'artois, F-7008 Paris http://www.cigre.org B2-301 Session 200 CIGRÉ IMPROVING DOUBLE CIRCUIT TRANSMISSION LINE RELIABILITY THROUGH LIGHTNING DESIGN J. A. (TONY) GILLESPIE & GLENN STAPLETON Powerlink

More information

When surge arres t ers are installed close to a power transformer, overvoltage TRANSFORMER IN GRID ABSTRACT KEYWORDS

When surge arres t ers are installed close to a power transformer, overvoltage TRANSFORMER IN GRID ABSTRACT KEYWORDS TRANSFORMER IN GRID When surge arres t ers are installed close to a power transformer, they provide protection against lightning overvoltage ABSTRACT The aim of this research article is to determine the

More information

Comparison between Different InstallationLocations of Surge Arresters at Transmission Line Using EMTP-RV

Comparison between Different InstallationLocations of Surge Arresters at Transmission Line Using EMTP-RV No. E-13-HVS-2308 Comparison between Different InstallationLocations of Surge Arresters at Transmission Line Using EMT-RV Soheil Derafshi Beigvand, Mohammad Morady Electrical Engineering Department, Engineering

More information

MODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT

MODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT MODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT Claus NEUMANN Darmstadt University of Technology Germany claus.neumann@amprion.net Klaus WINTER Swedish Neutral

More information

WORLD MEETING ON LIGHTNING Lightning Performance Research on Mexican High Voltage Transmission Lines

WORLD MEETING ON LIGHTNING Lightning Performance Research on Mexican High Voltage Transmission Lines WORLD MEETING ON LIGHTNING 2016 Lightning Performance Research on Mexican High Voltage Transmission Lines Carlos ROMUALDO-TORRES, PhD (Eng) Instituto de Investigaciones Eléctricas MEXICO This paper describes:

More information

LIGHTNING OVERVOLTAGES AND THE QUALITY OF SUPPLY: A CASE STUDY OF A SUBSTATION

LIGHTNING OVERVOLTAGES AND THE QUALITY OF SUPPLY: A CASE STUDY OF A SUBSTATION LIGHTNING OVERVOLTAGES AND THE QUALITY OF SUPPLY: A CASE STUDY OF A SUBSTATION Andreas SUMPER sumper@citcea.upc.es Antoni SUDRIÀ sudria@citcea.upc.es Samuel GALCERAN galceran@citcea.upc.es Joan RULL rull@citcea.upc.es

More information

GIS Disconnector Switching Operation VFTO Study

GIS Disconnector Switching Operation VFTO Study GIS Disconnector Switching Operation VFTO Study Mariusz Stosur, Marcin Szewczyk, Wojciech Piasecki, Marek Florkowski, Marek Fulczyk ABB Corporate Research Center in Krakow Starowislna 13A, 31-038 Krakow,

More information

Lightning Overvoltages on Low Voltage Circuit Caused by Ground Potential Rise

Lightning Overvoltages on Low Voltage Circuit Caused by Ground Potential Rise Lightning Overvoltages on Low Voltage Circuit Caused by Ground Potential Rise S. Sekioka, K. Aiba, S. Okabe Abstract-- The lightning overvoltages incoming from an overhead line such as a power distribution

More information

Calculation of Transient Overvoltages by using EMTP software in a 2-Phase 132KV GIS

Calculation of Transient Overvoltages by using EMTP software in a 2-Phase 132KV GIS Calculation of Transient Overvoltages by using EMTP software in a 2-Phase 132KV GIS M. Kondalu, Dr. P.S. Subramanyam Electrical & Electronics Engineering, JNT University. Hyderabad. Joginpally B.R. Engineering

More information

Grounding and Lightning 1

Grounding and Lightning 1 12 Grounding and Lightning 1 Robert S. Nowell Georgia Power Company 12.1 Lightning Stroke Protection... 12-1 The Design Problem 12.2 Lightning Parameters... 12-2 Strike Distance Stroke Current Magnitude

More information

Lightning Overvoltage Performance of 110 kv Air-Insulated Substation

Lightning Overvoltage Performance of 110 kv Air-Insulated Substation Lightning Overvoltage Performance of 11 kv Air-Insulated Substation B. Filipović-Grčić, B. Franc, I. glešić, V. Milardić, A. Tokić Abstract--This paper presents the analysis of lightning overvoltage performance

More information

Research on Lightning Over-voltage and Lightning Protection of 500kV. HGIS Substation

Research on Lightning Over-voltage and Lightning Protection of 500kV. HGIS Substation International Conference on Manufacturing Science and Engineering (ICMSE 2015) Research on Lightning Over-voltage and Lightning Protection of 500kV HGIS Substation Tong Wang1, a *and Youping Fan1, b 1

More information

Analysis of MOV Surge Arrester Models by using Alternative Transient Program ATP/EMTP

Analysis of MOV Surge Arrester Models by using Alternative Transient Program ATP/EMTP IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 2 August 216 ISSN (online): 2349-784X Analysis of MOV Surge Arrester Models by using Alternative Transient Program ATP/EMTP

More information

Utility System Lightning Protection

Utility System Lightning Protection Utility System Lightning Protection Many power quality problems stem from lightning. Not only can the high-voltage impulses damage load equipment, but the temporary fault that follows a lightning strike

More information

A Methodology for the Efficient Application of Controlled Switching to Current Interruption Cases in High-Voltage Networks

A Methodology for the Efficient Application of Controlled Switching to Current Interruption Cases in High-Voltage Networks A Methodology for the Efficient Application of Controlled Switching to Current Interruption Cases in High-Voltage Networks C. D. TSIREKIS Hellenic Transmission System Operator Kastoros 72, Piraeus GREECE

More information

Lightning current waves measured at short instrumented towers: The influence of sensor position

Lightning current waves measured at short instrumented towers: The influence of sensor position GEOPHYSICAL RESEARCH LETTERS, VOL. 32, L18804, doi:10.1029/2005gl023255, 2005 Lightning current waves measured at short instrumented towers: The influence of sensor position Silvério Visacro and Fernando

More information

Lightning Current Observation on UHVAC Transmission Lines by Improved Magnetic Steel Rod Method

Lightning Current Observation on UHVAC Transmission Lines by Improved Magnetic Steel Rod Method Sensors & Transducers 2014 by IFSA Publishing, S. L. http://www.sensorsportal.com Lightning Current Observation on UHVAC Transmission Lines by Improved Magnetic Steel Rod Method Anfeng Jiang, Zhengcai

More information

Experimental Study on Lightning Surge Response of 500kV Transmission Tower with Overhead Lines

Experimental Study on Lightning Surge Response of 500kV Transmission Tower with Overhead Lines Experimental Study on Lightning Surge Response of 500kV Transmission Tower with Overhead Lines H. Motoyama, CRIEPI, Japan motoyama@criepi.denken.or.jp Y. Kinoshita, Chube Electric Power Co., Inc., Japan

More information

Lightning current field measurement on a transmission line, comparison with electromagnetic transient calculations

Lightning current field measurement on a transmission line, comparison with electromagnetic transient calculations Lightning current field measurement on a transmission line, comparison with electromagnetic transient calculations A. Xemard, M. Mesic, T. Sadovic, D. Marin, S. Sadovic Abstract- A lightning experiment

More information

Session Four: Practical Insulation Co-ordination for Lightning Induced Overvoltages

Session Four: Practical Insulation Co-ordination for Lightning Induced Overvoltages Session Four: ractical Insulation Co-ordination Session Four: ractical Insulation Co-ordination for Lightning Induced Overvoltages Jason Mayer Technical Director, Energy Services, Aurecon Introduction

More information

Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems

Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems F. Amanifard* and N. Ramezani** Abstract: The article presents the transients analysis of the substation

More information

The Effect of Lightning Parameters on Induced Voltages Caused by Nearby Lightning on Overhead Distribution Conducting Line.

The Effect of Lightning Parameters on Induced Voltages Caused by Nearby Lightning on Overhead Distribution Conducting Line. The Effect of Lightning Parameters on Induced Voltages Caused by Nearby Lightning on Overhead Distribution Conducting Line. J.O. Adepitan, Ph.D. 1 and Prof. E.O. Oladiran 2 1 Department of Physics and

More information

The Analysis Results of Lightning Overvoltages by EMTP for Lightning Protection Design of 500 kv Substation

The Analysis Results of Lightning Overvoltages by EMTP for Lightning Protection Design of 500 kv Substation The Analysis Results of Lightning Overvoltages by EMTP for Lightning Protection Design of 500 kv Substation J. W. Woo, J. S. Kwak, H. J. Ju, H. H. Lee, J. D. Moon Abstract--To meet increasing power demand,

More information

Three-dimensional FEM model of an AC/DC hybrid high voltage transmission line to analyze the electrical field along composite insulators

Three-dimensional FEM model of an AC/DC hybrid high voltage transmission line to analyze the electrical field along composite insulators Threedimensional FEM model of an AC/DC hybrid high voltage transmission line to analyze the electrical field along composite insulators D. Potkrajac, S. Papenheim, M. Kizilcay AbstractTo increase the power

More information

Lightning Protection of Distribution Substations by Using Metal Oxide Gapless Surge Arresters Connected in Parallel

Lightning Protection of Distribution Substations by Using Metal Oxide Gapless Surge Arresters Connected in Parallel International Journal of Power and Energy Research, Vol. 1, No. 1, April 2017 https://dx.doi.org/10.22606/ijper.2017.11001 1 Lightning Protection of Distribution Substations by Using Metal Oxide Gapless

More information

Including Surge Arresters in the Lightning Performance Analysis of 132kV Transmission Line

Including Surge Arresters in the Lightning Performance Analysis of 132kV Transmission Line ncluding Surge Arresters in the Lightning Performance Analysis of 32kV Transmission Line Saeed Mohajeryami, Milad Doostan University of North Carolina at Charlotte Department of Electrical and Computer

More information

Analysis of current distribution among long-flashover arresters for 10 kv overhead line protection against direct lightning strikes

Analysis of current distribution among long-flashover arresters for 10 kv overhead line protection against direct lightning strikes 2014 International onference on Lightning Protection (ILP), Shanghai, hina nalysis of current distribution among long-flashover arresters for 10 kv overhead line protection against direct lightning strikes

More information

EXPERIMENTAL INVESTIGATION OF A TRANSIENT INDUCED VOLTAGE TO AN OVERHEAD CONTROL CABLE FROM A GROUNDING CIRCUIT

EXPERIMENTAL INVESTIGATION OF A TRANSIENT INDUCED VOLTAGE TO AN OVERHEAD CONTROL CABLE FROM A GROUNDING CIRCUIT EXPERIMENTAL INVESTIGATION OF A TRANSIENT INDUCED VOLTAGE TO AN OVERHEAD CONTROL CABLE FROM A GROUNDING CIRCUIT Akihiro AMETANI, Tomomi OKUMURA, Naoto NAGAOKA, Nobutaka, MORI Doshisha University - Japan

More information

Prepared by Mick Maytum

Prepared by Mick Maytum IEC Technical Committee 109: Standards on insulation co-ordination for low-voltage equipment Warning Prepared by Mick Maytum mjmaytum@gmail.com The document content is of a general nature only and is not

More information

Statistical analysis of overvoltages due to the energisation of a 132 kv underground cable

Statistical analysis of overvoltages due to the energisation of a 132 kv underground cable University of Wollongong Research Online Faculty of Engineering and Information Sciences - Papers: Part A Faculty of Engineering and Information Sciences 2009 Statistical analysis of overvoltages due to

More information

The Influences of Soil Ionization in the Grounding System and Corona Phenomena on the Injection Lightning Current of 1000 KV UHV Transmission Line

The Influences of Soil Ionization in the Grounding System and Corona Phenomena on the Injection Lightning Current of 1000 KV UHV Transmission Line International Academic Institute for Science and Technology International Academic Journal of Science and Engineering Vol. 3, No. 9, 2016, pp. 1-12. ISSN 2454-3896 International Academic Journal of Science

More information

ABSTRACT 1.0 INTRODUCTION LIST OF SYMBOLS

ABSTRACT 1.0 INTRODUCTION LIST OF SYMBOLS Lightning protection of pole-mounted transformers and its applications in Sri Lanka Prof. J R Lucas* and D A J Nanayakkara # *University of Moratuwa, # Lanka Transformers Limited ABSTRACT This paper presents

More information

APPLICATION OF LONG FLASHOVER ARRESTERS FOR IMPROVEMENT OF LIGHTNING PROTECTION AND OPERATING VOLTAGE RELIABILITY OF DISTRIBUTION LINES

APPLICATION OF LONG FLASHOVER ARRESTERS FOR IMPROVEMENT OF LIGHTNING PROTECTION AND OPERATING VOLTAGE RELIABILITY OF DISTRIBUTION LINES APPLICATION OF LONG FLASHOVER ARRESTERS FOR IMPROVEMENT OF LIGHTNING PROTECTION AND OPERATING VOLTAGE RELIABILITY OF DISTRIBUTION LINES G. V. Podporkin, V. E. Pilshikov, A. D. Sivaev Streamer Electric

More information

The impact of recent advances on lightning measurement and detection on the protection of transmission and distribution lines

The impact of recent advances on lightning measurement and detection on the protection of transmission and distribution lines Current [ka] Current [ka] 1 The impact of recent advances on lightning measurement and detection on the protection of transmission and distribution lines Silverio Visacro, IEEE Member Abstract Recent technological

More information

The Many Uses of Transmission Line Arresters

The Many Uses of Transmission Line Arresters Introduction It was not realized at the time, but the 1992 introduction of the polymer-housed transmission line arrester (TLA) was clearly a game changer in the practice of lightning protection of transmission

More information

Modeling for the Calculation of Overvoltages Stressing the Electronic Equipment of High Voltage Substations due to Lightning

Modeling for the Calculation of Overvoltages Stressing the Electronic Equipment of High Voltage Substations due to Lightning Modeling for the Calculation of Overvoltages Stressing the Electronic Equipment of High Voltage Substations due to Lightning M. PSALIDAS, D. AGORIS, E. PYRGIOTI, C. KARAGIAΝNOPOULOS High Voltage Laboratory,

More information

Substation Insulation Coordination Study

Substation Insulation Coordination Study [Type the document title] Substation nsulation Coordination Study MEG Energy Christina Lake Regional Project nsulation Coordination Schematic X0057 15km Lines TWR3 TWR2 TWR1 Afrm1 16 230k Source CCT 100

More information

AORC Technical meeting 2014

AORC Technical meeting 2014 http : //www.cigre.org B4-112 AORC Technical meeting 214 HVDC Circuit Breakers for HVDC Grid Applications K. Tahata, S. Ka, S. Tokoyoda, K. Kamei, K. Kikuchi, D. Yoshida, Y. Kono, R. Yamamoto, H. Ito Mitsubishi

More information

Lightning transient analysis in wind turbine blades

Lightning transient analysis in wind turbine blades Downloaded from orbit.dtu.dk on: Aug 15, 2018 Lightning transient analysis in wind turbine blades Candela Garolera, Anna; Holbøll, Joachim; Madsen, Søren Find Published in: Proceedings of International

More information

CHOICE OF MV FEEDER BIL TO MAXIMIZE QOS AND MINIMIZE EQUIPMENT FAILURE

CHOICE OF MV FEEDER BIL TO MAXIMIZE QOS AND MINIMIZE EQUIPMENT FAILURE CHOICE OF MV FEEDER BIL TO MAXIMIZE QOS AND MINIMIZE EQUIPMENT FAILURE Willem DIRKSE VAN SCHALKWYK ESKOM - South Africa vschalwj@eskom.co.za ABSTRACT A high BIL (300 kv) on a MV feeder ensures that no

More information

ATP SIMULATION OF FARADAY CAGE FOR THE ANALYSIS OF LIGHTNING SURGES

ATP SIMULATION OF FARADAY CAGE FOR THE ANALYSIS OF LIGHTNING SURGES ATP SIMULATION OF FARADAY CAGE FOR THE ANALYSIS OF LIGHTNING SURGES Mehmet Salih Mamis Cemal Keles 1 Muslum Arkan 1 Ramazan Kaya 2 Inonu University, Turkey 1 Inonu University, Engineering Faculty, Electrical

More information

Insulation Co-ordination For HVDC Station

Insulation Co-ordination For HVDC Station Insulation Co-ordination For HVDC Station Insulation Co-ordination Definitions As per IEC 60071 Insulation Coordination is defined as selection of dielectric strength of equipment in relation to the operating

More information

Simulation Study on Transient Performance of Lightning Over-voltage of Transmission Lines

Simulation Study on Transient Performance of Lightning Over-voltage of Transmission Lines 7th Asia-Pacific International Conference on Lightning, November 1-4, 2011, Chengdu, China Simulation Study on Transient Performance of Lightning Over-voltage of Transmission Lines Zihui Zhao, Dong Dang,

More information

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models International Journal of Electrical & Computer Sciences IJECS-IJENS Vol:15 No:03 39 Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models Shen-Wen Hsiao, Shen-Jen

More information

In order to minimise distribution (11 and 22 kv) feeder breaker

In order to minimise distribution (11 and 22 kv) feeder breaker Lightning protection for equipment on MV feeders By WJD van Schalkwyk and M du Preez, Eskom This article presents the influence of lightning on MV feeders supplying small power users (400/230 V) with focus

More information

Cable Protection against Earth Potential Rise due to Lightning on a Nearby Tall Object

Cable Protection against Earth Potential Rise due to Lightning on a Nearby Tall Object Cable Protection against Earth Potential Rise due to Lightning on a Nearby Tall Object U. S. Gudmundsdottir, C. F. Mieritz Abstract-- When a lightning discharge strikes a tall object, the lightning current

More information

Accurate Modeling of Core-Type Distribution Transformers for Electromagnetic Transient Studies

Accurate Modeling of Core-Type Distribution Transformers for Electromagnetic Transient Studies IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 17, NO. 4, OCTOBER 2002 969 Accurate Modeling of Core-Type Distribution Transformers for Electromagnetic Transient Studies Taku Noda, Member, IEEE, Hiroshi Nakamoto,

More information

Effect of Shielded Distribution Cables on Lightning-Induced Overvoltages in a Distribution System

Effect of Shielded Distribution Cables on Lightning-Induced Overvoltages in a Distribution System IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 17, NO. 2, APRIL 2002 569 Effect of Shielded Distribution Cables on Lightning-Induced Overvoltages in a Distribution System Li-Ming Zhou, Senior Member, IEEE,

More information

Backflashover Analysis for 110-kV Lines at Multi-Circuit Overhead Line Towers

Backflashover Analysis for 110-kV Lines at Multi-Circuit Overhead Line Towers Backflasover Analysis for 11-kV Lines at Multi-Circuit Overead Line Towers M. Kizilcay, C. Neumann Abstract-- An increase of back-flasovers in a 11-kV system as been observed along an overead line route

More information

A Simple Simulation Model for Analyzing Very Fast Transient Overvoltage in Gas Insulated Switchgear

A Simple Simulation Model for Analyzing Very Fast Transient Overvoltage in Gas Insulated Switchgear A Simple Simulation Model for Analyzing Very Fast Transient Overvoltage in Gas Insulated Switchgear Nguyen Nhat Nam Abstract The paper presents an simple model based on ATP-EMTP software to analyze very

More information

Analysis of Switching Transients of an EHV Transmission Line Consisting of Mixed Power Cable and Overhead Line Sections

Analysis of Switching Transients of an EHV Transmission Line Consisting of Mixed Power Cable and Overhead Line Sections Analysis of Switching Transients of an EHV Transmission Line Consisting of Mixed Power Cable and Overhead Line Sections M. Kizilcay, K. Teichmann, S. Papenheim, P. Malicki Abstract -- Within the scope

More information

Evaluation of coupling between dc and ac transmission lines on the same right-of-way: Parametric analysis and mitigation methods

Evaluation of coupling between dc and ac transmission lines on the same right-of-way: Parametric analysis and mitigation methods Abstract: Evaluation of coupling between dc and ac transmission lines on the same right-of-way: Parametric analysis and mitigation methods Jingxuan (Joanne) Hu RBJ Engineering Corp. Winnipeg, MB, Canada

More information

Fatima Michael college of Engineering and Technology

Fatima Michael college of Engineering and Technology Fatima Michael college of Engineering and Technology DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE2303 TRANSMISSION AND DISTRIBUTION SEM: V Question bank UNIT I INTRODUCTION 1. What is the electric

More information

The Simulation Experiments on Impulse Characteristics of Tower Grounding Devices in Layered Soil

The Simulation Experiments on Impulse Characteristics of Tower Grounding Devices in Layered Soil International Journal of Engineering and Technology, Vol. 9, No., February 7 The Simulation Experiments on Impulse Characteristics of Tower Grounding Devices in Layered Soil Leishi Xiao, Qian Li, Zhangquan

More information

EE 1402 HIGH VOLTAGE ENGINEERING

EE 1402 HIGH VOLTAGE ENGINEERING EE 1402 HIGH VOLTAGE ENGINEERING Unit 5 TESTS OF INSULATORS Type Test To Check The Design Features Routine Test To Check The Quality Of The Individual Test Piece. High Voltage Tests Include (i) Power frequency

More information

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables J Electr Eng Technol Vol. 9, No. 2: 628-634, 2014 http://dx.doi.org/10.5370/jeet.2014.9.2.628 ISSN(Print) 1975-0102 ISSN(Online) 2093-7423 A Study on Lightning Overvoltage Characteristics of Grounding

More information

Transmission Line Transient Overvoltages (Travelling Waves on Power Systems)

Transmission Line Transient Overvoltages (Travelling Waves on Power Systems) Transmission Line Transient Overvoltages (Travelling Waves on Power Systems) The establishment of a potential difference between the conductors of an overhead transmission line is accompanied by the production

More information

TECHNICAL NOTE 2.0. Overvoltages origin and magnitudes Overvoltage protection

TECHNICAL NOTE 2.0. Overvoltages origin and magnitudes Overvoltage protection ECHNICAL NOE 2.0 Overvoltages origin and magnitudes Overvoltage protection he ECHNICAL NOES (N) are intended to be used in conjunction with the APPLICAION GIDELINES Overvoltage protection Metaloxide surge

More information

Effect of High Frequency Cable Attenuation on Lightning-Induced Overvoltages at Transformers

Effect of High Frequency Cable Attenuation on Lightning-Induced Overvoltages at Transformers Voltage (kv) Effect of High Frequency Cable Attenuation on Lightning-Induced Overvoltages at Transformers Li-Ming Zhou, Senior Member, IEEE and Steven Boggs, Fellow, IEEE Abstract: The high frequency attenuation

More information

Metal-Oxide Surge Arresters Integrated in High-Voltage AIS Disconnectors An Economical Solution for Overvoltage Protection in Substations

Metal-Oxide Surge Arresters Integrated in High-Voltage AIS Disconnectors An Economical Solution for Overvoltage Protection in Substations Metal-Oxide Surge Arresters Integrated in High-Voltage AIS Disconnectors An Economical Solution for Overvoltage Protection in Substations Volker Hinrichsen, Reinhard Göhler Helmut Lipken Wolfgang Breilmann

More information

CHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES

CHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES 23 CHAPTER 2 v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES 2.1 INTRODUCTION For reliable design of power system, proper insulation coordination among the power system equipment is necessary. Insulation

More information

A Study of Lightning Surge on Underground Cables in a Cable Connection Station

A Study of Lightning Surge on Underground Cables in a Cable Connection Station Proceedings of the 6th WSEAS International Conference on Instrumentation, Measurement, Circuits & Systems, Hangzhou, China, April 1517, 2007 198 A Study of Lightning Surge on Under Cables in a Cable Connection

More information

The relationship between operating maintenance and lightning overvoltage in distribution networks based on PSCAD/EMTDC

The relationship between operating maintenance and lightning overvoltage in distribution networks based on PSCAD/EMTDC The relationship between operating maintenance and lightning overvoltage in distribution networks based on PSCAD/EMTDC Xiaojun Chena *, Wenjie Zhengb, Shu Huangc, Hui Chend Electric Power Research Institute

More information

Investigation of Transmission Line Overvoltages and their Deduction Approach

Investigation of Transmission Line Overvoltages and their Deduction Approach Investigation of Transmission Line Overvoltages and their Deduction Approach A. Hayati Soloot, A. Gholami, E. Agheb, A. Ghorbandaeipour, and P. Mokhtari Abstract The two significant overvoltages in power

More information

OVERVOLTAGE MEASUREMENTS RELATED TO LIGHTNING- DETECTION SYSTEMS IN NORWAY

OVERVOLTAGE MEASUREMENTS RELATED TO LIGHTNING- DETECTION SYSTEMS IN NORWAY 3p.3 OVERVOTAGE MEASUREMENTS REATED TO IGHTNING- DETECTION SYSTEMS IN NORWAY H. K. Høidalen F. Dahlslett hans.hoidalen@elkraft.ntnu.no Norwegian University of Science and Technology Norway frank.dahlslett@energy.sintef.no

More information

High voltage engineering

High voltage engineering High voltage engineering Overvoltages power frequency switching surges lightning surges Overvoltage protection earth wires spark gaps surge arresters Insulation coordination Overvoltages power frequency

More information

Electric Power Systems Research

Electric Power Systems Research Electric Power Systems Research 94 (2013) 54 63 Contents lists available at SciVerse ScienceDirect Electric Power Systems Research j ourna l ho me p a ge: www.elsevier.com/locate/epsr Calculation of overvoltage

More information

X International Symposium on Lightning Protection

X International Symposium on Lightning Protection X International Symposium on Lightning Protection 9 th -13 th November, 2009 Curitiba, Brazil LIGHTNING SURGES TRANSFERRED TO THE SECONDARY OF DISTRIBUTION TRANSFORMERS DUE TO DIRECT STRIKES ON MV LINES,

More information

Appendix B to Working on Exposed Energized Parts

Appendix B to Working on Exposed Energized Parts Working on Exposed Energized Parts. - 1910.269 App B Regulations (Standards - 29 CFR) - Table of Contents Part Number: 1910 Part Title: Occupational Safety and Health Standards Subpart: R Subpart Title:

More information

Testing 320 kv HVDC XLPE Cable System

Testing 320 kv HVDC XLPE Cable System Testing 320 kv HVDC XLPE Cable System H. He, W. Sloot DNV GL, KEMA Laboratories Arnhem, The Netherlands Abstract Two unique test requirements in testing of a high- voltage direct- current (HVDC) cable

More information

Power Quality and Reliablity Centre

Power Quality and Reliablity Centre Technical Note No. 8 April 2005 Power Quality and Reliablity Centre TRANSIENT OVERVOLTAGES ON THE ELECTRICITY SUPPLY NETWORK CLASSIFICATION, CAUSES AND PROPAGATION This Technical Note presents an overview

More information

Protection against unacceptable voltages in railway systems

Protection against unacceptable voltages in railway systems Bernhard Richter*, Alexander Bernhard*, Nick Milutinovic** SUMMERY Based on the system voltages for AC and DC railway systems the required voltage ratings for modern gapless MO surge arresters are given.

More information

EVALUATION OF LIGHTNING-INDUCED VOLTAGES ON LOW-VOLTAGE DISTRIBUTION NETWORKS

EVALUATION OF LIGHTNING-INDUCED VOLTAGES ON LOW-VOLTAGE DISTRIBUTION NETWORKS IX International Symposium on Lightning Protection 6 th - th November 7 Foz do Iguaçu, Brazil EVALUATION OF LIGHTNING-INDUCED VOLTAGES ON LOW-VOLTAGE DISTRIBUTION NETWORKS Fernando H. Silveira Silvério

More information

SWITCHING OVERVOLTAGES IN A 400-KV CABLE SYSTEM

SWITCHING OVERVOLTAGES IN A 400-KV CABLE SYSTEM SWITCHING OVERVOLTAGES IN A 4-KV CABLE SYSTEM Mustafa Kizilcay University of Siegen Siegen, Germany kizilcay@uni-siegen.de Abstract This paper deals with the computation of switching overvoltages in a

More information