Measuring Gunshots with Commercial Sound Level Meters

Size: px
Start display at page:

Download "Measuring Gunshots with Commercial Sound Level Meters"

Transcription

1 Measuring Gunshots with Commercial Sound Level Meters Deanna K. Meinke, Ph.D. Gregory A. Flamme, Ph.D. William J. Murphy, Ph.D. Donald S. Finan, Ph.D. Michael Stewart, Ph.D. Stephen M. Tasko, Ph.D. James E. Lankford, Ph.D.

2 Disclaimers The findings and conclusions in this presentation have not been formally disseminated by the National Institute for Occupational Safety and Health and should not be construed to represent any agency determination or policy. The sound level meters utilized in this study were a convenience sample of instruments commercially available at the time of the study, and were either owned by the researchers or provided on loan by the manufacturer.

3 Introduction Gunshot sound levels are frequently measured using commercial sound level meters primarily for the identification of peak sound pressure levels for regulatory or policy compliance and ultimately to determine risk of auditory damage. Commercially available sound level meters are marketed specifically for the purposes of impulse noise measurements. The measurement data from these sound level meters can be obtained from more than one source; the LED display reading and from the AC output data file.

4 Research Questions How does the accuracy of the impulse noise measurements made with a commercial sound level meter compare to the gold standard laboratory system measurements? Are there differences between the sound level meter LED display output values and the AC output values?

5 Sound Level Meter Basic Block Diagram Digital Signal Acquisition & Processing Fast, Slow = Log db AC Output DC Output

6 Methods: Environment Rudyard, Michigan Field Site

7 Methods: Sound Level Meters (n=5) Make Model PreAmp Mic Weighting Larson Davis 831 LXT PRMLXT1 PCB 377C10 Z 824 PRM902 B&K 4136 Z 824 PRM902 B&K 4136 Z 831 PRM831 PCB 377C10 Z 3M Sound Pro Integral Quest QE 4110 Z

8 Methods: Experimental Set-up Colt AR-15 Rifle shooting Federal American Eagle.223 Remington 55 grain FMJ

9 Methods: Experimental Set-up Each meter tested at 5 different peak SPLs: 130, 140, 150, 160 and 170 db

10 Methods: Experimental Set-up Each meter tested at 5 different peak SPLs: 130, 140, 150, 160 and 170 db

11 Methods: Experimental Set-up All Mics: Grazing incidence, separated by 1 inch, 1.5 meter height; Calibrated pre and post measurement for each test position

12 Methods: Experimental Set-up Laboratory System:

13 Methods: Experimental Set-up 1 Researcher per Station to read and report LED display after shot fired

14 Methods: Data Analysis Excel for recording SLM display quantities MATLAB for gold standard system and SLM AC output Peak, LAeq8, AHAAH AHU (warned), AHAAH AHU (unwarned) Stata for inferential statistics Mixed regression model, with observations nested within shots

15 Results AC output versus display value Peak LAeq8

16 Results Accuracy of SLM AC peak SPLs

17 Results Accuracy of SLM AC peak SPLs

18 Results Accuracy of SLM AC LAeq8

19 Results Accuracy of SLM Warned AHU

20 Results Accuracy of SLM Unwarned AHU

21 Results Accuracy of MPE estimates MPE error ratio (SLM / Field) LD LXT LD 831 LD LD M SoundPro LD LXT LD 831 LD LD M SoundPro LD LXT LD 831 LD LD M SoundPro LD LXT LD 831 LD LD M SoundPro LD LXT LD 831 LD LD M SoundPro LIAeq100ms AHU Warned LAeq8 AHU Unwarned

22 Results Mixed-model ANOVA Dependent variables assessed Peak, LAeq8, A-duration, Warned AHU, Unwarned AHU Model DV = peak + meter + peak*meter Observations nested within shots Bonferroni adjustment

23 Results Mixed-model ANOVA A-duration model was not significant, all others were. 95 % CI for marginal means does not include zero in most cases. Especially for Peak and LAeq8 Between-meter significant differences begin at 140 peak db SPL. At 140: At 170: Peak, LAeq8 Warned AHU, Unwarned AHU

24 Conclusions Sound level meters are not a replacement for a field research system Rigorous testing of any system is necessary Adequate microphone specifications are necessary, but not sufficient for accuracy Preamp, AC output, and recording apparatus must be able to handle the impulse signal Display dynamic range AC output dynamic range Accuracy declines with increasing level

25 Implications Use of a commercial sound level meter utilized for impulse noise measurements may underestimate auditory hazard for impulse sound levels at or above approximately 150 db peak SPL. Purchasing a new 1/8 inch microphone may not necessarily extend the range of your measurements. Sound level meter instrument specifications may need to specify the accuracy and range for specific outputs and impulse levels.

26 Raise your hand if you have questions

Measuring Recreational Firearm Noise

Measuring Recreational Firearm Noise Measuring Recreational Firearm Noise Per Rasmussen, G.R.A.S. Sound & Vibration, Holte, Denmark Greg Flamme, Western Michigan University, Kalamazoo, Michigan Michael Stewart, Central Michigan University,

More information

Testing to IEC

Testing to IEC APPENDIX B Testing to IEC61672-1 This appendix presents information for measuring the sound level meter functionality of the LxT according to IEC61672-1. Sections 5, 6, 7 and 9 (except 9.3) The following

More information

ABSTRACT. Noise Monitoring Results. from. The USAF atmospheric interceptor technology (ait) launch From the Kodiak Launch Complex (KLC)

ABSTRACT. Noise Monitoring Results. from. The USAF atmospheric interceptor technology (ait) launch From the Kodiak Launch Complex (KLC) ABSTRACT Noise Monitoring Results from The USAF atmospheric interceptor technology (ait) launch From the Kodiak Launch Complex (KLC) As part of the monitoring and mitigation obligation of the United States

More information

Manufacturer Calibration Certificate

Manufacturer Calibration Certificate Manufacturer Calibration Certificate The sound meter submitted for testing successfully completed the periodic tests of IEC 61672-3. All tests are traceable in accordance with ISO/IEC 17025. This model

More information

CORRECTION NOTICE SOUTH AFRICAN CIVIL AVIATION AUTHORITY CIVIL AVIATION ACT, 2009 (ACT NO. 13 OF 2009)

CORRECTION NOTICE SOUTH AFRICAN CIVIL AVIATION AUTHORITY CIVIL AVIATION ACT, 2009 (ACT NO. 13 OF 2009) CORRECTION NOTICE SOUTH AFRICAN CIVIL AVIATION AUTHORITY CIVIL AVIATION ACT, 2009 (ACT NO. 13 OF 2009) The Director of Civil Aviation has, in terms of section 163(1) of the Civil Aviation Act, 2009 (Act

More information

P R O D U C T D A T A

P R O D U C T D A T A P R O D U C T D A T A PULSE Acoustic Material Testing in a Tube Type 7758 PULSE Acoustic Material Testing in a Tube Type 7758 is software for determining the acoustical properties of noise control materials

More information

SoundExpert TM LxT. n Site Assessment Run/Pause Control. Display Navigation. Dual Purpose Start/Stop Reset/Clear Memory. Recessed On/Off Button

SoundExpert TM LxT. n Site Assessment Run/Pause Control. Display Navigation. Dual Purpose Start/Stop Reset/Clear Memory. Recessed On/Off Button n n Standard 1/2 inch Free Field or Random Incidence Microphone Integrated Preamplifier Collar to Eliminate Reflections Applications n Product Noise Evaluation Large High Resolution Display One-button

More information

REPORT DOCUMENTATION PAGE

REPORT DOCUMENTATION PAGE REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions,

More information

SoundExpert TM LxT. Display Navigation. Dual Purpose Start/Stop Reset/Clear Memory. Recessed On/Off Button. USB Host (Thumb Drive Storage)

SoundExpert TM LxT. Display Navigation. Dual Purpose Start/Stop Reset/Clear Memory. Recessed On/Off Button. USB Host (Thumb Drive Storage) n n Standard 1/2 inch Free Field or Random Incidence Microphone Integrated Preamplifier Collar to Eliminate Reflections Applications n Product Noise Evaluation n Production Line Acoustic Testing n Site

More information

TPS 49 EDITION 2 JUNE 2009

TPS 49 EDITION 2 JUNE 2009 TPS 49 EDITION 2 JUNE 2009 Interim arrangements & guidance on the interpretation of IEC 61672 Sound Level Meters - Periodic Tests CONTENTS SECTION PAGE 1 Purpose and duration 2 2 Statement 2 3 Specific

More information

Lesson 3 Measurement of sound

Lesson 3 Measurement of sound Lesson 3 Measurement of sound 1.1 CONTENTS 1.1 Contents 1 1.2 Measuring noise 1 1.3 The sound level scale 2 1.4 Instruments used to measure sound 6 1.5 Recording sound data 14 1.6 The sound chamber 15

More information

SoundExpert LxT Sound Level Meter:

SoundExpert LxT Sound Level Meter: n n Standard 1/2 inch Free Field or Random Incidence Microphone Integrated Preamplifier Collar to Eliminate Reflections Applications n Product Noise Evaluation Large High Resolution Display One-button

More information

Acoustic Calibration Service in Automobile Field at NIM, China

Acoustic Calibration Service in Automobile Field at NIM, China Acoustic Calibration Service in Automobile Field at NIM, China ZHONG Bo National Institute of Metrology, China zhongbo@nim.ac.cn Contents 1 Overview of Calibration Services 2 Anechoic Room Calibration

More information

CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording

CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording Environmental Noise Boundary noise assessments Noise nuisance complaints Measurements

More information

Division of Physical Metrology Center for Fluid Flow & Acoustics Korea Research Institute of Science & Standards Hyu-Sang Kwon & Wan-Ho Cho

Division of Physical Metrology Center for Fluid Flow & Acoustics Korea Research Institute of Science & Standards Hyu-Sang Kwon & Wan-Ho Cho Report on the Bilateral Comparison between KRISS & NIM Division of Physical Metrology Center for Fluid Flow & Acoustics Korea Research Institute of Science & Standards Hyu-Sang Kwon & Wan-Ho Cho Introduction

More information

Understanding distance shooting and the type of firearm from the analysis of gunshot sounds

Understanding distance shooting and the type of firearm from the analysis of gunshot sounds Understanding distance shooting and the type of firearm from the analysis of gunshot sounds Nikolaos E. Tsiatis Police Major Forensic Science Division of Hellenic Police, Athens, Greece Abstract In order

More information

Report on Research Activities of KRISS CCAUV

Report on Research Activities of KRISS CCAUV Report on Research Activities of KRISS CCAUV Division of Physical Metrology Center for Fluid Flow & Korea Research Institute of Standards and Science KRISS - CCAUV Dr. H. S. Kwon hyusang@kriss.re.kr (Air,

More information

Errata to Procedural Standard for Sound & Vibration Measurement 2015 Third Edition

Errata to Procedural Standard for Sound & Vibration Measurement 2015 Third Edition Errata to Procedural Standard for Sound & Vibration Measurement 2015 Third Edition Correction Sheet #1 Issued 01 July 2018 Copyright 2018 by NEBB All rights reserved. Published 2018. Printed in the United

More information

Boggabri Coal Mine. Environmental Noise Monitoring October Prepared for Boggabri Coal Operations Pty Ltd

Boggabri Coal Mine. Environmental Noise Monitoring October Prepared for Boggabri Coal Operations Pty Ltd Boggabri Coal Mine Environmental Noise Monitoring October 2017 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring October 2017 Reference: Report date:

More information

Interior Noise Characteristics in Japanese, Korean and Chinese Subways

Interior Noise Characteristics in Japanese, Korean and Chinese Subways IJR International Journal of Railway Vol. 6, No. 3 / September, pp. 1-124 The Korean Society for Railway Interior Noise Characteristics in Japanese, Korean and Chinese Subways Yoshiharu Soeta, Ryota Shimokura*,

More information

An experimental investigation of cavity noise control using mistuned Helmholtz resonators

An experimental investigation of cavity noise control using mistuned Helmholtz resonators An experimental investigation of cavity noise control using mistuned Helmholtz resonators ABSTRACT V Surya Narayana Reddi CHINTAPALLI; Chandramouli PADMANABHAN 1 Machine Design Section, Department of Mechanical

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring February 2018 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring February 2018 Reference:

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring April 2016 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring April 2016 Reference: Report

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring May 2018 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring May 2018 Reference: Report date:

More information

Certificate of Calibration Sound Level Meter

Certificate of Calibration Sound Level Meter NTacoustic coustic Calibration & Testing Laboratory Level 1, 418 Elizabeth Street., Surry Hills NSW 2010 USTRLI Ph: (02) 8218 0570 email: service@natacoustic.com.au website: www.natacoustic.com.au division

More information

Boggabri Coal Mine. Environmental Noise Monitoring June Prepared for Boggabri Coal Operations Pty Ltd

Boggabri Coal Mine. Environmental Noise Monitoring June Prepared for Boggabri Coal Operations Pty Ltd Boggabri Coal Mine Environmental Noise Monitoring June 2017 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring June 2017 Reference: Report date: 5 July

More information

Measurement of Weighted Harmonic Distortion HI-2

Measurement of Weighted Harmonic Distortion HI-2 Measurement of Weighted Harmonic Distortion HI-2 Application Note for the R&D and QC SYSTEM (Document Revision 1.2) AN 7 DESCRIPTION The weighted harmonic distortion HI-2 can be measured by using the DIS-Pro

More information

Simpson Model Sound Level Meter OPERATOR S MANUAL

Simpson Model Sound Level Meter OPERATOR S MANUAL Simpson Model 886-2 Sound Level Meter OPERATOR S MANUAL About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the

More information

Simpson Model 899 Sound Level Meter OPERATOR S MANUAL

Simpson Model 899 Sound Level Meter OPERATOR S MANUAL Simpson Model 899 Sound Level Meter OPERATOR S MANUAL About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures

More information

TigerShark UAS Level Flyover Noise Measurements

TigerShark UAS Level Flyover Noise Measurements TigerShark UAS Level Flyover Noise Measurements Final 18 July 216 Adrian Sescu, Calvin Walker, Ratan Jha Mississippi State University Prepared for: Federal Aviation Administration Office of Environment

More information

Technical Report Noise and Vibration

Technical Report Noise and Vibration Technical Report Noise and Vibration Eagle Mine and Humboldt Mill Prepared for: Eagle Mine, LLC 4547 County Road 601 Champion, MI 49814 Date: August 8, 2014 TriMedia Project Number: 2014-083 Table of Contents

More information

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK.

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK. TECHNICAL REPORT 16 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK. FOR Gabriel Kelly Group Environmental Manager Dairygold Food ingredients Castlefarm Mitchelstown

More information

Appendix 8. Draft Post Construction Noise Monitoring Protocol

Appendix 8. Draft Post Construction Noise Monitoring Protocol Appendix 8 Draft Post Construction Noise Monitoring Protocol DRAFT CPV Valley Energy Center Prepared for: CPV Valley, LLC 50 Braintree Hill Office Park, Suite 300 Braintree, Massachusetts 02184 Prepared

More information

Technical Documentation

Technical Documentation Technical Documentation Microphone Type 4964 for Hand-held Analyzer Types 2250, 2250-L and 2270 Supplement to Instruction Manual BE 1712 English BE 1864 11 Microphone Type 4964 for Hand-held Analyzer

More information

An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements

An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements E. Aflalo a, F. Dupont a, P. Cellard b and J.-N. Durocher b a 01dB-Metravib,

More information

CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017.

CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017. CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017. Prepared for: CLARE COUNTY COUNCIL ÁRAS CONTAE AN CHLÁIR NEW ROAD ENNIS CO. CLARE 3156 May 16 th, 2017 EPA

More information

Ambient Level Controller

Ambient Level Controller Ambient Level Controller Installation and Use Manual Issue 1, October 1999 1999 Bogen Communications, Inc. All rights reserved. 54-2028-01 9910 Model: LUALC PEC Code: 5335-621 COM Code: 408184273 Select

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 WEST CALDWELL CALIBRATION LABORATORIES, INC. 1575 State Route 96 Victor, NY 14564 Felix Christopher Phone: 585 586 3900 CALIBRATION

More information

Measuring Center for Android User manual Software for analyzing sound signals

Measuring Center for Android User manual Software for analyzing sound signals 2014 Measuring Center for Android User manual Software for analyzing sound signals Spl-Lab Version 2.2 Table of Contents Table of Contents... 2 General Information... 3 Starting Operation... 3 Program

More information

Performance of Roadside Sound Barriers with Sound Absorbing Edges

Performance of Roadside Sound Barriers with Sound Absorbing Edges Performance of Roadside Sound Barriers with Sound Absorbing Edges Diffracted Path Transmitted Path Interference Source Luc Mongeau, Sanghoon Suh, and J. Stuart Bolton School of Mechanical Engineering,

More information

NoiseMeters. The Practical & Easy To Use Solution for Industrial & Environmental Noise Measurements.

NoiseMeters. The Practical & Easy To Use Solution for Industrial & Environmental Noise Measurements. NoiseMeters The Practical & Easy To Use Solution for Industrial & Environmental Noise Measurements. Simple to use solutions for occupational, general & environmental noise measurements Meets the latest

More information

Rubber, vulcanized or thermoplastic Determination of abrasion resistance using a rotating cylindrical drum device

Rubber, vulcanized or thermoplastic Determination of abrasion resistance using a rotating cylindrical drum device Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 4649 Fourth edition 2017-09 Rubber, vulcanized or thermoplastic Determination of abrasion resistance using a rotating cylindrical drum device Caoutchouc

More information

Model: M /800 MHz Mobile Radio

Model: M /800 MHz Mobile Radio Engineering and Testing for EMC and Safety Compliance Accredited Under NVLAP Lab Code 200061-0 RF Maximum Permissible Exposure (MPE) Report for Controlled and Uncontrolled Environments M/A-COM, Inc. 221

More information

Large capacity magazines and homicide

Large capacity magazines and homicide Carlisle E. Moody College of William and Mary College of William and Mary Department of Economics Working Paper Number 160 February, 2015 COLLEGE OF WILLIAM AND MARY DEPARTMENT OF ECONOMICS WORKING PAPER

More information

High intensity and low frequency tube sound transmission loss measurements for automotive intake components

High intensity and low frequency tube sound transmission loss measurements for automotive intake components High intensity and low frequency tube sound transmission loss measurements for automotive intake components Edward R. Green a) Sound Answers, Inc., 6855 Commerce Boulevard, Canton, Michigan, 48187 USA

More information

Radio Frequency Fields Survey at Waurn Ponds Campus Pigdons Road, Geelong, VIC For Deakin University. EMC Technologies Report No.

Radio Frequency Fields Survey at Waurn Ponds Campus Pigdons Road, Geelong, VIC For Deakin University. EMC Technologies Report No. Page 1 of 13 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Telephone + 613 9335 3333 Facsimile + 613 9338 9260 Email melb@emctech.com.au Radio Frequency

More information

Model Microphone Preamplifier Power Supply Manual

Model Microphone Preamplifier Power Supply Manual Model 2221 Microphone Preamplifier Power Supply Manual Larson Davis Model 2221 Microphone Preamplifier Power Supply Manual I2221.01 Rev H Copyright Copyright 2009-2015 by PCB Piezotronics, Inc. This manual

More information

SOUND FIELD MEASUREMENTS INSIDE A REVERBERANT ROOM BY MEANS OF A NEW 3D METHOD AND COMPARISON WITH FEM MODEL

SOUND FIELD MEASUREMENTS INSIDE A REVERBERANT ROOM BY MEANS OF A NEW 3D METHOD AND COMPARISON WITH FEM MODEL SOUND FIELD MEASUREMENTS INSIDE A REVERBERANT ROOM BY MEANS OF A NEW 3D METHOD AND COMPARISON WITH FEM MODEL P. Guidorzi a, F. Pompoli b, P. Bonfiglio b, M. Garai a a Department of Industrial Engineering

More information

Pfizer Ireland Pharmaceuticals

Pfizer Ireland Pharmaceuticals Allegro Acoustics Limited, Unit 2A Riverside, Tallaght Business Park, Tallaght, Dublin 24 Tel/Fax: +33 () 1 4148 Pfizer Ireland Pharmaceuticals Pfizer Grange Castle, Grange Castle Business Park, Clondalkin,

More information

NEW FROM PCB. Sensors & Instrumentation for Measuring Vibration, Sound, Torque, Pressure, Force, and Strain

NEW FROM PCB. Sensors & Instrumentation for Measuring Vibration, Sound, Torque, Pressure, Force, and Strain SENSORS FOR RESEARCH & DEVELOPMENT AND MACHINERY HEALTH MONITORING NEW FROM PCB Sensors & Instrumentation for Measuring Vibration, Sound, Torque, Pressure, Force, and Strain www.pcb.com info@pcb.com 800.828.8840

More information

FIREARM AND TOOL MARK SECTION SECTION 4 TECHNICAL PROCEDURES MANUAL JULY 1, 1996 FIRED BULLET/PROJECTILE EXAMINATION PROTOCOL

FIREARM AND TOOL MARK SECTION SECTION 4 TECHNICAL PROCEDURES MANUAL JULY 1, 1996 FIRED BULLET/PROJECTILE EXAMINATION PROTOCOL 4.0 Fired Bullet/Projectile Examination Protocol 4.1 Handle evidence bullets/projectiles carefully 4.1.1 Evidence bullets/projectiles that require a serological examination should have been routed to the

More information

C1.1 Specification of the SVAN 971 as SLM in the standard configuration

C1.1 Specification of the SVAN 971 as SLM in the standard configuration SVAN 971 USER MANUAL. C TECHNICAL SPECIFICATIONS C.1 Specification of SVAN 971 as sound level meter The following appendix effects for firmware version 1.11.1 or greater. C1.1 Specification of the SVAN

More information

Noise Exposure History Interview Questions

Noise Exposure History Interview Questions Noise Exposure History Interview Questions 1. A. How often (never, rarely, sometimes, usually, always) did your military service cause you to be exposed to loud noise(s) where you would have to shout to

More information

Keystone Pipeline Phases 1 & 2 Acoustic Monitoring Report for Canadian Pump Stations

Keystone Pipeline Phases 1 & 2 Acoustic Monitoring Report for Canadian Pump Stations Revision 0 Keystone Project Document # RE-03 [2-4-22-2] ATCO Project # 763000 TransCanada Pipeline Ltd. Keystone Pipeline Project Keystone Pipeline Phases 1 & 2 Acoustic Monitoring Report for Canadian

More information

Precision Integrating Sound Level Meter

Precision Integrating Sound Level Meter Precision Integrating Sound Level Meter Type 2236 A 009 Type 2236 B 009 Type 2236 C 009 Type 2236 D 009 With software version 2.1 or higher Revision November 1996 Brüel & Kjær BB0909 13 Trademarks IBM

More information

Antenna Factor Calculations and Deviations

Antenna Factor Calculations and Deviations Antenna Factor Calculations and Deviations INTRODUCTION In recent years, the use of a term call Antenna Factor in EMC and spectrum pollution work has become very important. There has been a great need

More information

ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements

ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements ODEON APPLICATION NOTE ISO 3382-3 Open plan offices Part 2 Measurements JHR, May 2014 Scope This is a guide how to measure the room acoustical parameters specially developed for open plan offices according

More information

Active Shooter Tactical Response Assistant Design Slides

Active Shooter Tactical Response Assistant Design Slides Active Shooter Tactical Response Assistant Design Slides Team : Ben McCall, Puja Patel, Joel Williams, Rohini Shah, Aryan Toughiry GMU Sponsors: Dr. Hintz & Dr. Wage 1/28 Network of nodes with microphone

More information

The design and calibration of low cost urban acoustic sensing devices. SONYC Sounds Of New York City

The design and calibration of low cost urban acoustic sensing devices. SONYC Sounds Of New York City The design and calibration of low cost urban acoustic sensing devices SONYC Sounds Of New York City C. Mydlarz NYU CUSP C. Shamoon NYC DEP M. Baglione, M Pimpinella The Cooper Union cmydlarz@nyu.edu Sounds

More information

PRACTICAL METHODOLOGY FOR FAST ENVIRONMENTAL FIELD MEASUREMENTS

PRACTICAL METHODOLOGY FOR FAST ENVIRONMENTAL FIELD MEASUREMENTS PRACTICAL METHODOLOGY FOR FAST ENVIRONMENTAL FIELD MEASUREMENTS PACS REFERENCE: 43.50.Sr Rodrigues, Rui M. G. C.; Carvalho, António P. O. University of Porto, Faculty of Engineering, Laboratory of Acoustics,

More information

In late 2011, The International Standards

In late 2011, The International Standards CISPR 32: New International Standard on Electromagnetic Emissions from Multimedia Equipment DAN HOOLIHAN Hoolihan EMC Consulting Lindstrom, Minnesota USA In late 2011, The International Standards Commission's

More information

TBM - Tone Burst Measurement (CEA 2010)

TBM - Tone Burst Measurement (CEA 2010) TBM - Tone Burst Measurement (CEA 21) Software of the R&D and QC SYSTEM ( Document Revision 1.7) FEATURES CEA21 compliant measurement Variable burst cycles Flexible filtering for peak measurement Monitor

More information

A Guide to Environmental Noise Measurement Terminology

A Guide to Environmental Noise Measurement Terminology A Guide to Environmental Noise Measurement inology A summary of parameters and functions shown by the Optimus Sound Level Meters and Trojan Noise Nuisance Recorder A FREE ebook from The Noise Experts Environmental

More information

AMPLITUDE MODULATION CASE STUDY AT THE LEONARDS HILL WIND FARM, VICTORIA, AUSTRALIA

AMPLITUDE MODULATION CASE STUDY AT THE LEONARDS HILL WIND FARM, VICTORIA, AUSTRALIA AMPLITUDE MODULATION CASE STUDY AT THE LEONARDS HILL WIND FARM, VICTORIA, AUSTRALIA W Les Huson 1 1 L Huson & Associates Pty Ltd les@lhuson.com ABSTRACT Results of two channel simultaneous audio recordings

More information

APPLICATION NOTES CONNECTING A COLLABORATE ROOM TO A CONVERGE PRO. Purpose: Connecting the COLLABORATE Room to the CONVERGE Pro:

APPLICATION NOTES CONNECTING A COLLABORATE ROOM TO A CONVERGE PRO. Purpose: Connecting the COLLABORATE Room to the CONVERGE Pro: APPLICATION NOTES CLEARONE DOCUMENT 801-000-000-10 (REVISION 1.0) September, 2012 CONNECTING A COLLABORATE ROOM TO A CONVERGE PRO Purpose: This application note will describe the steps needed to interface

More information

AMPLIFIER RESEARCH... APPLICATION NOTE: 20

AMPLIFIER RESEARCH... APPLICATION NOTE: 20 AMPLIFIER RESEARCH... APPLICATION NOTE: 20 AMPLIFIER RESEARCH PRODUCTS THAT PROVIDE 20 V/m CW OR PM AT A DISTANCE OF 1 METER 1 The Amplifier / Antenna / Cell combinations shown in Table 1 provide various

More information

McGill Environmental Ltd.

McGill Environmental Ltd. McGill Environmental Ltd. Coom, Glenville, Co. Cork Environmental Noise Survey Report Date: 7 th October 2016 For inspection purposes only. KD Environmental Ltd. 1 Swiftbrook Glen, Virginia, Co. Cavan

More information

DiGi++ Noise Meter. Main functions

DiGi++ Noise Meter. Main functions Main functions DiGi++ Noise Meter This application brings the functionalities of a Sound Level Meter (SLM) and of a Spectrum Analizer (RTA) to your phone: mobile hardware introduce some limitations (lower

More information

PURPLE LINE EXTENSION SECTION 2 AMBIENT NOISE LEVEL REPORT METRO PROJECT RODEO STATION

PURPLE LINE EXTENSION SECTION 2 AMBIENT NOISE LEVEL REPORT METRO PROJECT RODEO STATION PURPLE LINE EXTENSION SECTION 2 AMBIENT NOISE LEVEL REPORT METRO PROJECT 865522 RODEO STATION Kleinfelder Section Table of Contents 1.0 Introduction... 4 2.0 Noise Measurement Procedure... 4 3.0 Noise

More information

ISO INTERNATIONAL STANDARD. Acoustics Unattended monitoring of aircraft sound in the vicinity of airports

ISO INTERNATIONAL STANDARD. Acoustics Unattended monitoring of aircraft sound in the vicinity of airports INTERNATIONAL STANDARD ISO 20906 First edition 2009-12-15 Acoustics Unattended monitoring of aircraft sound in the vicinity of airports Acoustique Surveillance automatique du bruit des aéronefs au voisinage

More information

National Accelerator LaboratoryFERMILAB-TM-1966

National Accelerator LaboratoryFERMILAB-TM-1966 Fermi National Accelerator LaboratoryFERMILAB-TM-1966 Use of Passive Repeaters for Tunnel Surface Communications Dave Capista and Dave McDowell Fermi National Accelerator Laboratory P.O. Box 500, Batavia,

More information

CEL 200 Series Simple Sound Level Meters

CEL 200 Series Simple Sound Level Meters CEL 200 Series Simple Sound Level Meters Casella USA is proud to announce the CEL-200 Series of sound level meters. These FAQ s help to give an overview of the current models, answer some of the more typical

More information

Ashton Coal. Environmental Noise Monitoring May Prepared for Ashton Coal Operations Pty Ltd

Ashton Coal. Environmental Noise Monitoring May Prepared for Ashton Coal Operations Pty Ltd Ashton Coal Environmental Noise Monitoring May 2018 Prepared for Ashton Coal Operations Pty Ltd Page i Ashton Coal Environmental Noise Monitoring May 2018 Reference: Report date: 5 June 2018 Prepared for

More information

Products contained in this shipment may be subject to ITAR regulations.

Products contained in this shipment may be subject to ITAR regulations. Products contained in this shipment may be subject to ITAR regulations. Warning: The export of these commodity(ies), technology, or software are subject either to the U.S. Commerce Department Export Administration

More information

Muswellbrook Coal Company

Muswellbrook Coal Company Muswellbrook Coal Company Environmental Noise Monitoring November 2015 Prepared for Muswellbrook Coal Page i Muswellbrook Coal Company Environmental Noise Monitoring November 2015 Reference: Report date:

More information

Background Ambient Noise Study Rosemont Copper

Background Ambient Noise Study Rosemont Copper Background Ambient Noise Study Rosemont Copper Prepared for: Rosemont Copper 40 Cherry Creek South Drive, Ste. 10 Denver, Colorado 246 (3) 0-0138 Fax (3) 0-0135 Prepared by: 31 West Ina Road Tucson, Arizona

More information

LabVIEW Based Instrumentation and Experimental Methods Course

LabVIEW Based Instrumentation and Experimental Methods Course Session 2259 LabVIEW Based Instrumentation and Experimental Methods Course Chi-Wook Lee Department of Mechanical Engineering University of the Pacific Stockton, CA 95211 Abstract Instrumentation and Experimental

More information

WHITEPAPER WHITEPAPER

WHITEPAPER WHITEPAPER WHITEPAPER WHITEPAPER Radio Frequency Emissions Analysis of Radio Frequency Exposure Associated with Silver Spring Networks Advanced Metering Devices Executive Summary This document provides information

More information

ICS Ultra-Low Noise Microphone with Differential Output

ICS Ultra-Low Noise Microphone with Differential Output Ultra-Low Noise Microphone with Differential Output GENERAL DESCRIPTION The ICS-40720* is an ultra-low noise, differential analog output, bottom-ported MEMS microphone. The ICS-40720 includes a MEMS microphone

More information

Psycho-acoustics (Sound characteristics, Masking, and Loudness)

Psycho-acoustics (Sound characteristics, Masking, and Loudness) Psycho-acoustics (Sound characteristics, Masking, and Loudness) Tai-Shih Chi ( 冀泰石 ) Department of Communication Engineering National Chiao Tung University Mar. 20, 2008 Pure tones Mathematics of the pure

More information

Advanced Dynamic Signal Analysis

Advanced Dynamic Signal Analysis Advanced Dynamic Signal Analysis James Zhuge, Ph.D. Crystal Instruments Corporation 4633 Old Ironsides Drive, Suite 304 Santa Clara, CA 95054, USA www.go-ci.com (Part of CoCo-80 User s Manual) COPYRIGHT

More information

IDENTIFICATION OF NOISE SOURCES ON LONGWALL PANELS USING MULTIPLE TIME-SYNCHRONIZED DOSIMETERS

IDENTIFICATION OF NOISE SOURCES ON LONGWALL PANELS USING MULTIPLE TIME-SYNCHRONIZED DOSIMETERS IDENTIFICATION OF NOISE SOURCES ON LONGWALL PANELS USING MULTIPLE TIME-SYNCHRONIZED DOSIMETERS E. Spencer, NIOSH, Pittsburgh, PA D. Babich, NIOSH, Pittsburgh, PA L. Alcorn, NIOSH, Pittsburgh, PA A. Smith,

More information

Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex

Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex Report ref. PJ3159/13181 Date August 13 Issued to Cuadrilla Resources Limited Issued by Peter Jackson MSc MIOA

More information

Audio Measurements Workshop

Audio Measurements Workshop Audio Measurements Workshop Fons Adriaensen Casa della Musica, Parma Linux Audio Conference 2014 ZKM Karlsruhe, Germany 1 Overview ζ Techniques and tools to measure * Soundcards * Analog hardware * DSP

More information

ICS Ultra-Low Noise Microphone with Differential Output

ICS Ultra-Low Noise Microphone with Differential Output Ultra-Low Noise Microphone with Differential Output GENERAL DESCRIPTION The ICS-40730 is an ultra-low noise, differential analog output, bottom-ported MEMS microphone. The ICS-40730 includes a MEMS microphone

More information

NEODYMIUM DYNAMIC TOM-TOM DRUM MICROPHONE PERCUSSION MICROPHONES

NEODYMIUM DYNAMIC TOM-TOM DRUM MICROPHONE PERCUSSION MICROPHONES NEODYMIUM DYNAMIC TOM-TOM DRUM MICROPHONE PERCUSSION MICROPHONES Table Of Contents Introduction and Features 3 Mounting the QTOM 4 Using The QTOM 5 QTOM Characteristics 6 QTOM Wiring 7 Specifications 7

More information

The Development of an Enhanced Strain Measurement Device to Support Testing of Radioactive Material Packages*

The Development of an Enhanced Strain Measurement Device to Support Testing of Radioactive Material Packages* P The Development of an Enhanced Strain Measurement Device to Support Testing of Radioactive Material Packages* W. L. Uncapher and M. Awiso Transportation Systems Department Sandia National Laboratories**

More information

! Warning, refer to accompanying documents.

! Warning, refer to accompanying documents. About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 PCB PIEZOTRONICS INC. 3425 Walden Avenue Depew, NY 14043 David J. Dulanski Phone: 716 684 0002 ext 2617 CALIBRATION

More information

RADIATED EMISSIONS MEASUREMENTS IN AN OPEN AREA TEST SITE

RADIATED EMISSIONS MEASUREMENTS IN AN OPEN AREA TEST SITE RADIATED EMISSIONS MEASUREMENTS IN AN OPEN AREA TEST SITE Dennis Handlon Agilent Technologies 1400 Fountaingrove Parkway, Santa Rosa CA 95403 Telephone 707 577 4206, dennis_handlon@non.agilent.com Abstract:

More information

ICS Ultra-Low Noise Microphone with Differential Output

ICS Ultra-Low Noise Microphone with Differential Output Ultra-Low Noise Microphone with Differential Output GENERAL DESCRIPTION The is an ultra-low noise, differential analog output, bottom-ported MEMS microphone. The includes a MEMS microphone element, an

More information

Muswellbrook Coal Company

Muswellbrook Coal Company Muswellbrook Coal Company Environmental ise Monitoring May 2015 Prepared for Muswellbrook Coal Page i Muswellbrook Coal Company Environmental ise Monitoring May 2015 Reference: Report date: 18 June 2015

More information

Soltec (Ireland) Limited Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report

Soltec (Ireland) Limited Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report 2013 Licence Number: W0115-01 Report Date: 09 th July 2013 Report Number: 3220-13-03 Version 0 AXIS environmental services 40 Coolraine

More information

AMPLIFIER RESEARCH... APPLICATION NOTE: 23

AMPLIFIER RESEARCH... APPLICATION NOTE: 23 AMPLIFIER RESEARCH... APPLICATION NOTE: 23 PRODUCTS THAT PROVIDE 200 V/m CW OR PM AT A DISTANCE OF 1 METER 1 The Amplifier / Antenna / Cell combinations shown in Table 1 provide various means of generating

More information

in Process Control System Presented by:

in Process Control System Presented by: Leakage Diagnosis in Process Control System Presented by: Haris M. Khalid Outline Problem Statement Leakage Diagnosis : A critical Issue A proposed Diagnostic Scheme Approaches Employed for Leakage Detection

More information

ASSIGNMENT: Directional Coupler

ASSIGNMENT: Directional Coupler ECE 323- MICROWAVE ENGINEERING LABORATORY 1 ASSIGNMENT: Directional Coupler I. OBJECTIVES Know the properties of directional couplers and their applications in microwave transmission and measurement systems.

More information

Resonance Mode Acoustic Displacement Transducer

Resonance Mode Acoustic Displacement Transducer Sensors & Transducers, Vol. 172, Issue 6, June 214, pp. 34-38 214 by IFSA Publishing, S. L. http://www.sensorsportal.com Resonance Mode Acoustic Displacement Transducer Tariq Younes, Mohammad Al Khawaldah,

More information

Retuning of FMIT #3 from 70.0 MHZ to 78.0 MHZ Charley Schwartz 10/28/02 DRAFT

Retuning of FMIT #3 from 70.0 MHZ to 78.0 MHZ Charley Schwartz 10/28/02 DRAFT Retuning of FMIT #3 from 70.0 MHZ to 78.0 MHZ Charley Schwartz 10/28/02 DRAFT This document serves two purposes, an entry into the engineering records of the process and data accumulated during the tuning

More information

Presented on. Mehul Supawala Marine Energy Sources Product Champion, WesternGeco

Presented on. Mehul Supawala Marine Energy Sources Product Champion, WesternGeco Presented on Marine seismic acquisition and its potential impact on marine life has been a widely discussed topic and of interest to many. As scientific knowledge improves and operational criteria evolve,

More information

CHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS

CHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS 35 CHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS 3.1 INTRODUCTION This chapter deals with the details of the design and construction of transmission loss suite, measurement details

More information