Bitronics PowerPlex Digital Power Transducer
|
|
- Britney Freeman
- 6 years ago
- Views:
Transcription
1 itronics Digital Power Transducer i t r o n i c s D / 3 r i o n The itronics instrument is a utility-grade, three-phase, digital power transducer that connects directly to instrument transformers. Direct-connect high-voltage inputs are also available. The design and components are field-proven in the substation environment with all inputs transformer isolated. The multiple microprocessor design uses advanced digital signal processing for true MS measurements including power. This instrument is a multifunction transducer that calculates Voltages, urrents, Power (real, reactive, apparent), Power Factor, Frequency, and Energy Values. eal-time Harmonics, K-Factor, Displacement Power Factor, and Demand measurements with Min/Max memory are also available. The itronics instrument is an Intelligent Electronic Device (IED) and stores these measured values in internal registers for serial communication access. The itronics instrument is designed to meet IE standard 1010 and is certified by Underwriters Laboratory to meet UL and S standards. Features Multiple measurements with accuracy and fast response Demand/Min/Max values with local/remote reset Direct connect up to 480V ac Supports input from reference potential Field-selectable element switch S-485, S-232, Modbus physical ports Modbus TU, DP3, Modbus protocol nalog utputs (with optional ) Universal Power Supply option a single supply that operates from 24, 48, 125, or 250V dc source or 115V ac service Self-diagnostics, network accessible outine calibration not required enefits to Design Engineers Precise and timely measurement of all needed parameters Easy to use and mount without expensive panel rework Simple connections for transmitting values to serial, analog or mixed systems. o post installation headaches with rugged, utility grade design Lowers purchase, installation and operating costs Precise and Fast Measurements The itronics transducer is a precise instrument for measuring multiple electrical parameters. True MS measurements are standard and accommodate signals containing harmonics in both current and voltage inputs. This results in accurate measurements despite waveform distortions. The instruments feature many per-phase measurements for phase-balance assessment. The itronics TH models provide additional demand and harmonic measurements by digitally integrating instantaneous samples to obtain thermal demand and harmonic values. These demand values are used to record the minimum and maximum thermal demand values since last reset. TS (Modbus only) models also measure volts, frequency, and phase difference from two power sources for synchronizing applications.
2 i t r o n i c s D / 3 r i o n ccuracy 0.25% ccuracy lass Frequency ccuracy is +/- 0.01Hz True MS Measurements include harmonics Energy 0 to 99,999,999 kwh for Import and Export 0 to 99,999,999 kvh for Import and Export Stored every 90 seconds in non-volatile memory. esettable from network. Frequency 45.00Hz to 75.00Hz measurement range Phase ngle Difference (TS only) +/- 0.3 degrees eal-time Measurements ll Voltage, urrent, Power, Power Factor, Frequency, and Energy parameters calculated every 100ms for T or 150ms for TH ll Harmonics, K-factor, Displacement Power Factor, and fundamental parameters calculated every 600ms Measurements Voltage Measurements True MS L- Voltage per Phase 4 True MS L-L Voltage per Phase 1 eference Voltage Fundamental Frequency eference Frequency Phase difference between Line and eference Voltage urrent Measurements True MS mps per Phase esidual eutral urrent 4 Power Measurements Watts per Phase 4 Total Three Phase Watts Vs per Phase 4 Total Three Phase Vs V per Phase 4 Total Three Phase V Power Factor per Phase 4 Total Three Phase Power Factor Energy Measurements Kilowatt-hours, Import and Export KiloV-hours, Import and Export % THD (Voltage) = where V 1 =Fundamental component of line voltage % TDD (urrent) = where I L =Maximum demand load current (user-programmable; if set to 0 then I L =I 1 for % THD measurement) Demand Min/Max Measurements (TH Models only) Present and Peak mp Demand per Phase Present and Peak esidual eutral mp Demand 4 Present, Max and Min Volt Demand per Phase Present, Max and Min Total Watt Demand Present, Max and Min Total V Demand Present, Max and Min Total V Demand Harmonic Measurements (TH Models only) ver 200 values: % TDD, % THD, Individual Harmonic omponents, K-Factor and Displacement Power Factor; includes many per phase and Peak values 1 alculated from L- inputs on 4-Wire systems 4 4-Wire systems only only available on TS models
3 Serial Transmission ptions educe wiring, terminations and input signal conditioning costs by transmitting the measurements to other digital devices using serial data communications. The family provides several serial options to interface with a wide variety of TUs, PLs, Ps, and other digital devices. The Modbus serial output option is a high-speed, high-capacity serial bus and protocol that is very suitable for real time distributed control and automation strategies. The S-485 bus is well suited for a medium speed multiple instrument monitoring system and has excellent noise immunity. The S-232 allows for short interconnection with a broad range of digital devices. The S-485 and the S-232 serial ports can be equipped with either Modbus TU or DP3 protocol. This provides for five combinations of serial ports and protocols that form network connections. Protocol hoices Modbus, certified by Schneider Electric, supports: 64 user selectable addresses; lobal Data, ead Holding egisters, and Preset Single/Multiple egisters for energy reset, demand reset, and scaling. Modbus TU Slave supports: 247 user selectable addresses; ead Holding egisters, and Preset Single/ Multiple egisters for energy reset, demand reset, and scaling. DP3 Slave supports: 256 user selectable addresses; ead by class, object or point; and Direct perate commands for energy reset, demand reset, and scaling. TH models include a configuration register to limit the class 0 response. PL Peer-to-Peer Serial Port Modbus, 9 pin D connector, 1Mbit/sec. Uses Modbus Protocol. S485 MDEM HMI nalog Transmissions ptions Transmit the itronics measurements to other devices using analog signals from a itronics nalog utput converter (). The communicates with the itronics serial port using Modbus TU or DP3 protocol over an S-485 bus, and then converts the register values to analog signals proportional to these measurements. Using a bus provides for several useful configurations. The S-485 bus allows for configurations with multiple instruments with cable runs up to 4000 feet (1200M). This distributed architecture also allows Hybrid configurations for use with mixed analog and serial solutions. nother useful feature of the distributed architecture is that the instruments can continue to be used, at no additional costs, when later upgrading to a serial communications network. The is equipped with 8 analog outputs, using either 0-1m or 4-20m signals S485 MDUS L TU ne-to-ne onfiguration S-485, 2-Wire, 9600 baud rate, screw barrier strip terminal block. Up to 4000 cable run. Use with Modbus TU (shown) or DP3 protocol. UP T 8 S485 MDUS UP T 8 L L TU Multiple onfiguration Use in a network, saves wiring and fully equipped for future serial network with TU. Use with Modbus TU (shown) or DP3 protocol. FIE MDEM S232 TU S485 MDUS Master Device TU or HMI Multidrop Serial Port S-485, 2-Wire, 9600 baud rate, screw barrier strip terminal block. Use with Modbus TU or DP3 protocol. UP T 7 L L TU S232 TU TEL SD UP T 7 ne-to-ne Serial Port S-232, 3-Wire, 9600 baud rate, screw barrier strip terminal block. Use with Modbus TU or DP3 protocol. Hybrid onfiguration Use in network and mix analog signals to TUs and serial signals to another device. Use with Modbus TU (shown) or DP3 protocol.
4 Easy Installation The itronics instruments are designed to make installation and maintenance a snap. They are loaded with features such as a metal case design with large stud terminals, mounting holes that match older power transducer designs, and wide temperature range. ll itronics models are available with the universal power supply which can operate from a wide variety of D or sources. The address and element-select switches are easily accessible from the front of the instrument. Diagnostic codes are available from the internal registers. Scaling for primary-side energy values, when connected to PTs and Ts, is provided through T and PT ratios written into registers over the network. free utility program is available for reading and writing ratios through the serial port. uxiliary Power Four power supply options 115V ac 230V ac 480V ac Universal /D supply: V ac or V dc iview Utility Software Setup and evaluation software is available View all register values Write T & PT ratios eset energy/demand Environment -30 to 70 operating temperature 2500V ac isolation to case 1500V ac minimum isolation input to output Meets IEEE/SI Surge Withstand Transducer meets IE standard and UL certified to meet UL and /S 22.2 o standards (5) (1) diagnostic LED provides communication status (2) power-on LED (3) Element switches 2-Element mode 2½-Element mode 3-Element mode (ot available on TS models) (4) address switches (5) Matches Watt/V analog power transducer mounting (6) Modbus port shown. S-232 and S-485 are 4-screw barrier strip terminal blocks. Provided with external MV transient protection for field replacement. (ot shown but mounts on power supply terminals.) (3) MDEL UET IPUTS I I I MTWD3 S/ DTE 2 1/2 VLTE IPUTS PT D L(+) (-) 3 2 ethlehem, P Made in US STTUS Vac 6W D or 50/60Hz (6) (2) (1) (4)
5 DEF DEF DEF DEF DEF DEF DEF DEF urrent Inputs ll itronics Instruments Supports the use of urrent transformers (T). These connections are made to internal transformers to provide excellent, utility grade isolation. Scaling for primary-side energy values when connected to Ts is provided through a T ratio written into the instrument through the serial port. Voltage Inputs itronics T and itronics TH Instruments Supports the use of Potential transformers (PT) or Voltage transformers (VT) for high voltage applications. These connections are made to internal transformers to provide excellent utility grade isolation. Scaling for primary-side energy values when connected to PTs is provided through a PT ratio written into the instrument through the serial port. The graphic shows a wiring schematic for a 3-Wire system. The family also supports 4-Wire systems which is field selectable by the element switch position. itronics TS Instruments Supports the use of Potential transformers (PT) or Voltage transformers (VT) for high voltage applications. lso supports the use of PT or VT from a reference source. These inputs are transformer-isolated to provide excellent utility grade isolation. Scaling forprimary-side energy values when connected to PTs is provided through a PT ratio written into the instrument through the serial port. The graphic shows a wiring schematic for a 3-Wire system. The TS also supports 2½-Element 4-Wire systems which is field selectable by the element switch position. (Does not support 3-Element because third PT input is used for reference voltage input.) The graphics show a wiring schematic for a 3-Wire system. The family also supports 4-Wire systems which is field selectable by the element switch position. UET IPUTS MDEL UET IPUTS I I I MTWD3 S/ DTE 2 1/2 PT D L(+) (-) VLTE IPUTS 3 2 ethlehem, P Made in US STTUS Voltage Inputs, itronics T and TH 120V ac nominal, range 0 to 150V ac Voltage signal burden <1m at 120V ac (0.1 V) MDEL I I I S/ MDEL MTWD3 DTE D L(+) (-) VLTE IPUTS UET IPUTS I I I VE S/ MTWI4 DTE PT 2 1/2 3 2 PT ethlehem, P Made in US 2 1/2 2 STTUS urrent Inputs, ll 5 ac nominal, range 0 to 10 ac ptional 1 ac nominal, range 0 to 2 ac urrent<signal burden 4mV at 5 ac (0.02 V) ethlehem, P Made in US STTUS Vac 6W D or 50/60Hz 6W Vac D or 50/60Hz 6W Vac D or 50/60Hz UET IPUTS I I I S/ MDEL MTWD DTE PT ethlehem, P Made in US D L(+) (-) VLTE IPUTS STTUS 3 2 D L(+) (-) VLTE IPUTS Voltage Inputs, itronics T and TH The MTWI1 and MTWD1 models are used for 240/208V L-L ac nominal, 3-Wire systems, and for 120 L- ac nominal, 4-Wire systems, range 0-375V ac The MTWI2 and MTWD2 models are used for 480 L-L ac nominal, 3-Wire systems and for 277 L- ac nominal, 4-Wire systems, range 0-520V ac Voltage signal burden <1.2m at 480V ac (0.6 V) 6W Vac D or 50/60Hz US TIE Voltage Inputs, itronics TS 120V ac nominal, range 0 to 150V ac Voltage signal burden <1m at 120V ac (0.1 V) itronics T and itronics TH Instruments Supports the direct connection of up to 480V ac L-L nominal for low voltage applications. These connections are made to internal transformers and continue to provide excellent utility grade isolation. Scaling is fixed for the appropriate voltage input range.
6 itronics 2, 2½ or 3-Elements / field selectable 2, 2½ or 3-Elements / field selectable Model: MTWI3 Models: MTWD3 S-232 or S-485/ Modbus TU or DP3 or Modbus S-232 or S-485/ Modbus TU or DP3 or Modbus See rder uide 167 See rder uide 168 itronics T itronics Multiomm TH 2 or 3-Elements / field selectable 2 or 3-Elements / field selectable Models: MTWI1 or MTWI2 Models: MTWID1 or MTWD2 S-232 or S-485/Modbus TU or DP3; or Modbus See rder uide 177 S-232 or S-485/Modbus TU or DP3; or Modbus itronics TS 2 or 2½-Elements / field selectable Models: MTWI4, MTWI5, MTWI6 / Phase,, or eference Modbus See rder uide 179 See rder uide 178 ccessories nalog utput onverter 0-1m, 4-20m / Models: 8101 or 8102; 8103 or 8104 S-485/Modbus TU; S-485/DP3 iview Setup and evaluation software The Engineer s hoice opyright 2010 ovatech, LL. ll rights reserved. ll brand and product names mentioned in this document are trademarks of their respective owners. ovatech and itronics are registered trademarks of ovatech, LL. The information in this literature is subject to change without notice and is not to be construed as a warranty. _PPlex_ ontact: ovatech, LL itronics Measurement and ecording 261 rodhead oad ethlehem, P T: F: E: bitronics@novatechweb.com itronics TH D/3 itronics T itronics Select Models rion Digital Power Transducer
MEASUREMENTS. BiTRONICS PowerPlex
MESUEMETS BiTICS Digital Power Transducer The instrument is an utility-grade, three-phase, digital power transducer that connects directly to instrument transformers. Direct-connect high-voltage inputs
More informationIntegra 1560 and 1580 Digital Transducer Systems
Integra 1560 and 1580 multi function transducers provide high accuracy
More informationRI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current
More informationPRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter
Telephone : 44 (0) 1245 428500 PRELIMIARY DATA SHEET RIF400 Series easywire Single and Three Phase Multifunction Energy Meter DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer
More informationPRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID
RIF300 Series easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer input with TASSCTEWA module)
More informationMICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2
PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features
More informationMID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID
Telephone : 44 (0) 1245 428500 RIF300 Series MID easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 1A Input from easywire CTs Single phase or three phase network
More informationPRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID
RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A
More informationRISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters
measures important electrical parameters in phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy
More information400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC
400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Electronic Load Electronic AC Loads, Interface overview RS-232 USB GPIB LAN System bus Analog X Analog isolated X Standard ption / not available 4226
More informationElectronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03
Electronic AC Load Series 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Rev. 3.03 Electronic AC Loads, Series Interface overview RS-232 USB GPIB LAN System bus Analog / Analog isolated X X Standard
More informationPower Meter Series PM3200 Functions and characteristics
Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring
More informationSmart Demand Controller
Smart Demand ontroller PowerLogic TM EM700 series Quick and easy installation Meter for all electrical panels Power energy monitoring PowerLogic TM EM700 - Smart Demand ontroller Functions and charteristics
More informationMultimeter 500CVD21 RTU500 series
Remote Terminal Units - Data sheet Multimeter 500CVD21 RTU500 series CT/VT interface with 4 voltage and 24 current inputs for direct monitoring of 3/4 wire 0 300 V AC (line to earth), 0...500 V AC (phase
More informationRI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA
More informationULTRA RAPID POWER QUALITY ANALYZER
ULTRA RAPID POWER QUALITY ANALYZER Ultra rapid (cycle by cycle) advanced electrical network analysis Complete network harmonics analysis, up to 63 rd harmonic High visibility, 5 graphic LCD screen with
More informationCROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM
CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and
More informationProgrammable DPM RISH EINE
Programmable PM RISH EIE ata Sheet www.rishabh.co.in Page 1 of 5 pplication : The digital panel meters RISH Eine PM have been designed for industrial applications, which frequently require precise and
More informationCROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM
CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and
More informationZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer
nalogue Meters With Moving - Iron Movement pplication IEGER PR-P The iegler PR-P transducer is used to measure and convert active, reactive, apparent power, Phase angle & Power Factor of a Single-phase
More informationTransducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features
Measuring Transducers Transducing electrical quantities Iskra MIS d.d. Measuring Transducers Features AC, DC POWER SYSTEM MEASUREMENT MICROPROCESSOR CONTROL HOUSING FOR DIN RAIL MOUNTING IN COMPLIANCE
More informationALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationRTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03
Multimeter 560CVD03 Without LCD Display There are several versions available: With LCD Display Figure 1 Type Display LO HI 1A 5A Versions R0031 3U3I x x x R0035 3U3I x x x R0051 3U3I x x x R0055 3U3I x
More informationMultifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU
Multifunction network analyzer Q15U2... - Q96U2L - Q96U4... Q15E2... - Q96E2... - MCU - MCUH Programmable transducer MCUU OPERATING MANUAL Ipm0163.8 - Edition 06.09 Langer Messtechnik GmbH Soyerhofstrasse
More informationPowerPlex RT & RTH. 3-Phase Multifunction Digital Transducer User Manual
PowerPlex RT & RTH 3-Phase Multifunction Digital Transducer User Manual October 2009 ML0004 Document Revision B 2009 by Bitronics, LLC REAL TIME INSTANTANEOUS (RT) No. MTWIN1B 2 & 3 Element (DELTA & WYE)
More informationInstallation and Operating Instructions
Energy Division Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Our commitment. Your advantage. Contents Page 1 Introduction 4 1.1 Measurement Capabilities 5 1.2
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of telemetry modules provide remote monitoring
More informationRISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:
Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit
More informationData Sheet. Earth Leakage Relay RISH ELR/ELR+/ELR VI/ELR VI(NE) A V RISH ELR VI. Record. Digital Protection Relay RESET TEST ENTER
ata Sheet arth eakage Relay RISH R/R+/R VI/R VI() RISH R VI 8.8. 8. 8. V R-1 R-2 igital Protection Relay K RST TST TR nalyze ata Sheet arth eakage Relay RISH R RISH arth eakage Relay is used to etect and
More informationRISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:
Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationSECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED
SECTION 16280 LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED PART 1 - GENERAL 1.1 SUMMARY This specification defines the requirements for active harmonic filter systems in order to meet IEEE-519-2014
More informationMultimeter 560CVD11 Data sheet
RTU500 series Multimeter 560CVD11 Data sheet The fault current is measured up to 20 times nominal current. The current inputs withstand 50 times nominal current for 1 s. The Multimeter is equipped with
More informationPowerLogic power-monitoring units. PM700 series power meter. Technical data sheet
PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required
More informationAlpha 50. Technical Data Sheet. Special Features
Technical ata Sheet lpha 50 lpha 50 is a compact multifunction instrument with touch screen LC utility which measures important electrical parameters in 3 phase and single phase Network & replaces the
More informationRISH ELR Earth Leakage Relay Preliminary Datasheet True RMS Measurement Trip relay cum DPM CBCT Open Detection 4 digit 7 segment LED display
RISH R arth eakage Relay Preliminary atasheet Technical atasheet RISH R RISH arth eakage Relay is used to etect and protect instruments from leakage current. RISH R VI RISH R VI RISH R VI is used to protect
More information1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.
Section 16680 VARIABLE SPEED DRIVE SYSTEMS OR AFD Part I - GENERAL I.01 Description A. This specification is to cover a complete adjustable frequency motor drive consisting of a pulse width modulated (PWM)
More informationMultiComm & MultiComm RTH
MultiComm & MultiComm RTH Modbus Plus Interface Option Manual September 27, 2011 ML0006 Document 2009 by Bitronics, LLC MTWIE4(A,B), MTWDE4(A,B) MTWIEC4(A,B), MTWDEC4(A,B) MTWIE5(A,B), MTWDE5(A,B) MTWIEC5(A,B),
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities
More informationMT 560/UMT TRANSDUCER & ANALYZER
MT 560/UMT 560 - TRANSDUCER & ANALYZER USE The MT 560/UMT 560 multi transducer and analyzer is used for a permanent analysis of electricity supply quality in compliance with the SIST EN 50160 standard.
More informationRISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:
(With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network
More informationAMIK 200 / 201 Technical Data Sheet
AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT
More informationEnergy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications
Energy Management Multifunction indicator Type WM12-DI Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase measurements:
More informationTechnical Data Sheet AMIK 300 / 301
USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important
More informationAcuvim-X Series Multifunction Power Meter
Series Multifunction Power Meter Power System Metering W a v e f o r m C a p t u r e O v e r L i m i t A l a r m emote Switch Control Power Quality Detection E n e r g y TO U C o u n t T r e n d e c o
More informationElectrical network management. Schneider Electric. PM3200 Technical Datasheet
Electrical network management Schneider Electric PM3200 Technical Datasheet Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact
More informationEM-72 Electricity Meters for Current Transformers
Product sheet MT8.18 Meter EM72 EM-72 Electricity Meters for Current Transformers EM72 electricty meters have been designed for panel mounting to monitor electricity consumption and the quality of the
More informationPower Quality and Energy Measurement PEM575
Power Quality and Energy Measurement _D00016_03_D_XXEN/12.2015 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical
More informationT/3000 T/3000. Substation Maintenance and Commissioning Test Equipment
T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY
More informationSECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)
ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX
More informationEnergy Division
Energy Division http://energy.tycoelectronics.com Installation and Operating Manual Integra 1560 and 1580 Digital Metering and Transducer Systems Tyco Electronics UK Limited Crompton Instruments Freebournes
More informationNK Technologies Ground Fault Sensor. Instrument Transformer AC Current Transducers NEW SPECIFICATIONS
Instrument Transformer urrent Transducers Large Window rea 4-20m The PL is a 4 terminal device with separate connections for power and load. The PM is a two terminal device. 24V is applied between the
More informationDigital Multifunction Instrument - Rish Master 3440
Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationArbiter Systems, Inc Vendels Circle, Suite 121 Paso Robles, CA USA
Model 931A Power System Analyzer Model 930A Three Phase Power Analyzer Model 929A Three Phase Power Meter with Digital Signal Analysis Model 931A shown with included accessories Arbiter Systems, Inc. Models
More informationEnergy Management Energy Meter Type EM21 72R Retro-Fit
Energy Management Energy Meter Type EM21 72R Retro-Fit Including 3 miniature split-core current sensors 10mm (90A), 16mm (150A) and 24mm (250A) diameter holes Class A (kwh) according to EN50470-3 Class
More informationMeasuring Transducer MT4xx series Programmable AC Current Transducer MT418
Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 o RMS AC current or frequency measurements o Current auto range measurements up to 12 A o Frequency measurement range 16 400 Hz
More informationDimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung
Dimension diagrams All dimensions in mm 73 mm 10 mm 35 mm 44 mm 90 mm 90 mm 107,5 mm 50 mm 76 mm 82 mm Front view Side view Typical connection An. In R32 RS485 Dig. I/O Versorgungsspannung Auxiliary Supply
More informationControllers FIELDPAC 348 Field-Mounted Controller
FIELP 48 Field-Mounted ontroller Introduction Features & enefits The need for only one wire pair to communicate with the control room reduces wiring costs ombines multiple loop components in a single package
More informationApplication: Salient Features: Products Features:
PHSE PRGRMME RISH PG / PGV pplication: The digital panel meters RISH have been designed for industrial applications, which frequently require precise and onsite adjustment of the display range. It can
More informationEASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter
SDM630MCT-RJV-333mV SDM630MCT-RJA-00mA Three phase multifunction din rail energy meter Plug-in solution; labor saving; wiring mistake free Measures kwh KVarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.
More informationInput Modules for TESLA Power System Recorders
Input Modules for TESLA Power System Recorders Modules Described In This Document DC Isolation Input Module - Model 401016 Input (ac or dc signals) AC Current Module - 5 A, new model 110739, old model
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of wireless I/O provides a low cost alternative
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, over-current protection relays, energy meters and transducers Primary injection testing capabilities
More informationALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationEnergy Management Energy Analyzer Type EM210 MID
Energy Management Energy Analyzer Type Multi-use housing: for both DIN-rail and panel mounting applications MID annex MI-003 (Measuring Instruments Directive) compliant Class B (kwh) according to EN50470-3
More information3 & 4 Wire Self Compensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg.
& 4 Wire Self ompensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg. FETURES S.S. 1L Face Material c/w Tri-lamp Mtg. Base Simple push-button calibration (ccurate) Output 4-20 m / 20-4
More informationImprove asset protection and utilization
QUALITROL 509 ITM Intelligent transformer monitor Improve asset protection and utilization Immediately know your transformer health with TransLife Optimize loading and equipment life Simplify root cause
More information905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use
Wireless New Products... New Solutions The range of telemetry modules provide remote monitoring and control by radio or twisted-pair wire, over short or long distances. Transducer signals connected at
More informationPower Quality and Energy Measurement PEM575
Power Quality and Energy Measurement _D00016_00_D_XXEN/06.2013 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical
More informationPower Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL
Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL 1.01 SUMMARY: The following technical specification describes the requirements of the high accuracy standalone 3 phase Power
More informationSUBJECT TO CHANGE WITHOUT NOTICE
TRNSUCERS & ISTRS Theta 30P www.sifamtinsley.co.uk TSHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders igital Panel Meters Current Transformers
More informationEnergy Management Compact Power Transducer Type CPT-DIN Basic version
Energy Management Compact Power ransducer ype CP-DI Basic version RS serial port on request Alarms (only from serial communication port) V, An Class (active energy) Class (reactive energy) Accuracy ±0..S.
More informationIsolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Frequency Input 5B45 / 5B46 FEATURES Isolated Frequency Input. Amplifies, Protects, Filters, and Isolates Analog Input. Generates an output of 0 to +5V proportional to input frequency. Model
More informationPower Quality and Energy Measurement PEM533
Power Quality and Energy Measurement _D00013_02_D_XXEN/11.2014 Power Quality and Energy Measurement 0.5 S Product description The digital universal measuring device is suited for measuring and displaying
More informationProgrammable AC Current Transducer MT418
Programmable AC Current Transducer MT418 RMS AC current measurements Current auto range measurements up to 12 A Frequency measurement range 16 400 Hz AC or universal wide auiliary power supply range 24
More informationTechnical Data Sheet. x1000. kwh R Y B
Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy
More informationDIRIS A40/A41 RS485 PROFIBUS DP. Operating instructions F GB D I NL E P. SOCOMEC GROUP switching PROTECTION & ups
DIRIS A40/A41 RS485 PROFIBUS DP Operating instructions F GB D I NL E P SOCOMEC GROUP switching PROTECTION & ups 2 DIRIS A20 - Réf. : 536 182 A GB 876_786_A_gb.indd 2 3/04/09 10:50:47 GB Contents PRELIMINARY
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading
More informationAdvanced, accurate and intelligent monitoring for your transformer
QUALITROL 505 ITM Intelligent transformer monitor Advanced, accurate and intelligent monitoring for your transformer The power to know your transformer health immediately with TransLife Advanced thermal
More informationPEM353. Universal measuring device
353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities
More informationME432 Three-phase Power Meter
ME432 Three-phase Power Meter Connectivity advantages MODEL ME432 Support Extra sensor Programmable digital output I/O function 333mV CT Rogowski coil Relay 1*digital output Power 85~265V AC/DC 1 Feature
More informationAutomation for a Changing World. Delta Power Meter DPM Series VARITEL
utomation for a hanging World Delta Power Meter DPM Series VRITEL VRITEL IGEIERI ELETROI S.. Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power quality
More informationEIG DNP V3.0 Protocol Assignments
E Electro Industries/G augetech "The Leader in Web Accessed Power Monitoring" EIG DNP V3.0 Protocol Assignments For Futura+ and DM Series Power Monitors Version 1.14 July 15, 2003 Doc # E100-7-03 V1.14
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 105U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 105U range of wireless I/O provides a low cost alternative
More informationPower quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I
Harmonics Temperature input Measurement accuracy 0.5 Memory 4 MByte UMG 104 Energy measurement device for DIN rails Communication Profibus (DP / V0 optional) Modbus RTU Power quality Harmonics up to 40th
More informationOHIO SEMITRONICS, INC. DIGITAL AC POWER MONITOR OSI SPECIFICATIONS
DIGITAL AC POWER MONITOR DESCRIPTION The DSP is a three-phase, three-element multifunction digital transducer with outputs for voltage, current, and power via serial communication. Applications include
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 105U ISO 9001 Certified New Products... New Solutions The ELPRO 105 range of telemetry modules provide remote monitoring and control by radio or twisted-pair
More informationEnergy Management Energy meters Type EM2-DIN
Energy Management Energy meters Type 6-dgt µp-based indicator Manual scrolling of partial and total energies: kwh, kvarh. TRMS measurement of distorted waves (voltage/current) All configuration functions
More information500 W up to 28,800 W 60 V up to 800 V 45 ma up to 2,700 A. Electronic Load ZS
500 W up to 28,800 W 60 V up to 800 V 45 ma up to 2,700 A Electronic Load AC Electronic Loads, Interface overview RS-232 USB GPIB LAN System bus Analog X Analog isolated X Standard ption / not available
More informationInstallation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems
Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Tyco Electronics UK Limited Crompton Instruments Freebournes Road, Witham, Essex, CM8 3AH, UK Tel: +44 1376 509 509
More informationEnergy Management Energy Analyzer Type EM210
Energy Management Energy Analyzer Type EM210 Multi-use housing: for both DIN-rail and panel mounting applications Current inputs AV option: CT 5A Current inputs MV option: current sensor 333 mv (CTV series)
More informationIQ Analyzer 6400/6600 Series
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities Power Quality Monitoring Over 150 metered parameters for comprehensive diagnostics Assess trends, harmonics
More informationLine-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts
digital ac POWER MONITOR DESCRIPTION The DSP is a three-phase, three-element multifunction digital transducer with outputs for voltage, current, and power via serial communication. Applications include
More information2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.
1.0 Scope This document describes the specification for Toshiba 1000 Series On-Line Uninterruptible Power System (UPS). The UPS will supply a computer grade AC output sine wave which is unaffected by the
More informationEnergy Management Energy Meter GM3T E GM3T-RS485 E
Energy Management Energy Meter GM3T E09 814 96 GM3T-RS485 E09 816 65 Certified according to MID Directive Product Description Three-phase energy meter with removable front LCD display unit. The same unit
More informationma/bcd Converter Model MFC-201 ma/bcd The MFC-201 ma/bcd Converter is a device designed to convert a DC current signal into BCD (8421) signals.
1 Definition ma/bcd Converter Model MFC-201 ma/bcd The MFC-201 ma/bcd Converter is a device designed to convert a DC current signal into BCD (8421) signals. 2 Operating Principle An electronic circuit
More informationEnergy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming
Energy Management Type WM14 DI version Protection degree (front): IP40 2 digital outputs 16 freely configurable alarms with OR/AD logic linkable with up to 2 digital outputs RS422/485 serial output (MODBUS-RTU),
More informationDigital Multifunction Meter - RISH Integra 2000
Features Four line graphic LCD display 1+ parameters Fast communications Customer configurable Easy to use Output options: 4 x -1mA 4 x 4-2mA 1 or 2 energy pulses Panel mounted Neutral current measurement
More informationENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID
Professionally approved products. Datasheet Stock Number: 144-0527 3 Phase Multi-function Power Meter 1/5A MID 96mm² Panel Mounted Power Meter. MID UK Specifications The 144-0527 is a new generation modern
More informationData Sheet. RISH Master Record %THD
Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy
More informationConzerv EM6400NG series
Conzerv EM6400NG series Multi-function power & energy meters Technical datasheet PB115131 Introducing EM6400NG, next generation power meters of iconic EM6400 series with innovative Accurate measurements